Document 6RGQxDrryNGXVEdQZdqrJYZ29
I
INTERNAL
I
CORRESPONDENCE
UNION CARBIDE CORPORATION Tf.f :i
; i rj ; f .
r-'u box rj jf.i
'Ti i r. A
ii ;i
)-)
BUSINESS CONFIDENTIAL A. F. Terry 704 Shop 511
July 24, 1986 i..- -
HS&EA
Industrial Hygiene
C. P. Maxwell R. G. Rowe, M.D. C. L. Ruddle R. E. Sergent
Asbestos Exposure Monitoring
Attached are the results of the Asbestos monitoring done in 8uilding 770 on June 23, 1986. R. E. Raines and R. P. Hess were monitored while they removed approximately 15 feet of Asbestos from a steam line inside of the S-5 air handler during off-hours. They were equipped with disposable coveralls, boots, disposable dust mask, gloves and head cover.
The air handler was shut down and the area was barricaded. Plastic was put on the floor, under the steam line, and excess water was used for wetting down the insulation. The Asbestos insulation, as well as the plastic was removed very diligently. The floor was flooded with water and vacuumed.
The sample results show that for the very short sampling time, the potential exposure to Asbestos was low. If it was averaged over an 8-hour period, it would be well below the permissible exposure level of 2 fiber/cc of air. An 8-hour average was not established because both R. E. Raines and R. P. Hess indicated that they worked with insulation, that may have contained Asbestos, earlier in the day before this job was done.
Please inform R. E. Raines and R. P. Hess of their exposure results and if we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
Vance E. Stover
VES/jac 1512P
Manhar A. Patel
UCC 024780
Comp Ref W/1999
Date 6-23-86
6-23-86
6-23-86
Sample Type Employee Name Personal/ R.E. Raines
Personal/ R. P. Hess
Area
ASBESTOS EXPOSURE MONITORING
Sampling Time
Air Cone Fibers/cc
TWAg Fibers/cc Comments
59 min
0.928
-----------
Collected while
removing and bag ging 15 feet of Asbestos from 770-S-5 Air Handler
58 min
1.35
-------------
Collected while removing and bagging 15 feet of Asbestos from 770-S-5 Air Handler
1 hr 3 min
0.420
-------------
Collected inside
of Air Handler about waist high setting on precipitron.
Asbestos Permissible Exposure Levels* TWAg 2 fibers/cc OSHA Ceiling 10 fibers/cc
* OSHA Guidelines in effect at time of monitoring.
1512P
UCC 024781