Document 6RGQxDrryNGXVEdQZdqrJYZ29

I INTERNAL I CORRESPONDENCE UNION CARBIDE CORPORATION Tf.f :i ; i rj ; f . r-'u box rj jf.i 'Ti i r. A ii ;i )-) BUSINESS CONFIDENTIAL A. F. Terry 704 Shop 511 July 24, 1986 i..- - HS&EA Industrial Hygiene C. P. Maxwell R. G. Rowe, M.D. C. L. Ruddle R. E. Sergent Asbestos Exposure Monitoring Attached are the results of the Asbestos monitoring done in 8uilding 770 on June 23, 1986. R. E. Raines and R. P. Hess were monitored while they removed approximately 15 feet of Asbestos from a steam line inside of the S-5 air handler during off-hours. They were equipped with disposable coveralls, boots, disposable dust mask, gloves and head cover. The air handler was shut down and the area was barricaded. Plastic was put on the floor, under the steam line, and excess water was used for wetting down the insulation. The Asbestos insulation, as well as the plastic was removed very diligently. The floor was flooded with water and vacuumed. The sample results show that for the very short sampling time, the potential exposure to Asbestos was low. If it was averaged over an 8-hour period, it would be well below the permissible exposure level of 2 fiber/cc of air. An 8-hour average was not established because both R. E. Raines and R. P. Hess indicated that they worked with insulation, that may have contained Asbestos, earlier in the day before this job was done. Please inform R. E. Raines and R. P. Hess of their exposure results and if we can be of further assistance, please call us on extension 4779 or 3750. WORK BY: APPROVED BY: Vance E. Stover VES/jac 1512P Manhar A. Patel UCC 024780 Comp Ref W/1999 Date 6-23-86 6-23-86 6-23-86 Sample Type Employee Name Personal/ R.E. Raines Personal/ R. P. Hess Area ASBESTOS EXPOSURE MONITORING Sampling Time Air Cone Fibers/cc TWAg Fibers/cc Comments 59 min 0.928 ----------- Collected while removing and bag ging 15 feet of Asbestos from 770-S-5 Air Handler 58 min 1.35 ------------- Collected while removing and bagging 15 feet of Asbestos from 770-S-5 Air Handler 1 hr 3 min 0.420 ------------- Collected inside of Air Handler about waist high setting on precipitron. Asbestos Permissible Exposure Levels* TWAg 2 fibers/cc OSHA Ceiling 10 fibers/cc * OSHA Guidelines in effect at time of monitoring. 1512P UCC 024781