Document 6RBdo6evGkaxBQ3MKLqQQ2vo9
34 Proc. ray. Soc. Med. Volume 70 January 1977
fibre counts and the electron microscopic asbestos mass calculations indicates that a positive cor relation exists between the two sets of data. These results show that the standard (OSHA) optical fibre counts may be only indicative of the total asbestos exposure.
Asbestos Exposure of Workmen After the identification of chrysoiile in the brake drum dusts, asbestos fibre exposure during main tenance and repair was determined by personal air sampling carried out at automobile repair shops.
taxi fleet repair shops and a municipal truck repair
shop in New York City. Air sampling and analyti cal methods for the determination of fibre con centrations were in accordance with the OSHA techniques (Bayer et ul. 1975). Present regulations of OSHA prohibit asbestos concentrations of 5
fibres per millilitre (fiml) or greater, longer than 5 pm as a time-weighted average, and con centrations above 2 f.'ml will be illegal after July 1976. Peak concentrations or maximum excursions of 10 (7ml are permitted by the regulations.
In brake lining inspection and repair, the wheel
Fie I Electron phoiomteroorophs ot broke drum dusts, taken at carious mayniticauons. a. the numerous chrysolite fibrils
hoce overoye lenolhs ol V.J u/ii or iess l x SO OVID. B. large iiumoers ot chrysoiile fibres imbedded in. anti proiniinnii Irani,
opaaue particle, probable pyrmizett phenolic resin binder i - JO 0011). C. laroe chrysolite hbre bundle I x tHJtil. D. ioroe
porttcie in ielt centre of photograph is the sonie us in c. but cannot be uleniineu at low mayniticaiion i x Joijij i
6001 0017
PRODUCED PY FORD