April 2, 1974
Mr. Earl Dundore Safety Director Clark Equipment Company . Lima Division, Box L 1046 S. Main St. Lima, Ohio 45802
Dear Mr. Dundore:
Enclosed are two copies of a report on the visits made to your company on March 12 and 13, 1974.
It vaa a pleasure to meet with you and other personnel and the courtesy extended was very much appreciated.
If this Division can he of assistance to your company at any time on
Industrial hygiene or engineering problems relating to safety, please
let us know.
1
Very truly yours,
"Maurice E. Hatten, P.E. Industrial Hygiene Engineer
MEB:Jkp
Left hearttfor OHIO for SAFETY
The
STATE OF OHIO
*
In dustrial C ommission o f Ohio
DIVISION OF SAFETY AND HYGIENE
U 28 w e a r n r r a a v k n u k COLUM 3U3. OHIO 43X04
433-3333
sxcaogrjunnwNt
MAIKRJtMTt M. MKAL
VtaaOMlmwi
JOHN C. SO M
JOHN J. GULUQAN Governor
DtvMen of txtaty m < HysNM , OAKY S . SftYMOt
SlWMmdMt April 3, 1974
CLASH EQUIPMENT COMPANY LIMA. DIVISION BOX L. 1046 S MAIN STREET LIMA, OHIO, 45802
1. On March 12 and 13, 1974, this company was visited in response to a company request for an industrial hygiene investigation.
2. Those contacted were:
3-12-74
Mr. Earl Dundore, Safety Director Mr. Robert Bromley, Personnel Manager Mr. Dennis Mault, Union Safety Comnitteeman Mr. James Holbrook, Electrician
3-13-74
Mr. Earl Dundore, Safety Director Mr. Robert Rowland, Safety Conmltteeaan Mr. Howard Kunkleman, General Foreman
3. The company manufactures very large cranes, draglines, back hoes, asphalt plants, and ocher heavy industrial equipment.
4. Sampling of shop dusts and other contaminants was done as outlined below:
D a t e D e p '.t f B l d g . # S a m p le # Sample Location Found. mg/M3 TLV. mg/M3
3-12-74 5
120
1
Central aisle, colan 2.3 Iron Oxide 10 (5, intend;
5-B-22, BZ
change)
3-12-74 6
119
2
6' from N, wall,
(l Iron Oxide
"
eolmn 5-C-3
(Visual) rep
laced by #5
3-13-74 9
106
3
10* NE of Column in 0.7 Oxide
"
WA 10, 7' from weld
i
operator, 6' from
r>
assemblyman, BZ
.
le ft hearIt for OHIO for SAFETY
. n n n i
Date Dep't # Bldg. # Sample # Sample Location Found. mg/M^
3-13-74 3 Adjacent to 4
BZ, Central aisle, 0.15 Chromium
0.1
dept. 9 Paint
about 30* from painting. Trioxide
area(overspray)
4' above floor
3-13-74 6
119
5
BZ, Column 5-B-4, ,, 2.4 Iron Oxide (5,inten*
about 50' from N
change)
wall, 1' above bench
3-13-74 13 Paint ship
6
BZ, several feet
0.10 Chromium
0.1
from operator, over
Trioxide
spray area.
3-13-74 15 Paint ship
7
BZ, about 2' above 2.7 Chromium
East end
floor, about 10'
Trioxide
from operator
Method of
Date Dep*t # Bldg. # Sample Location
Sibling Pound
TLV
3-12-74 5
120 Inside crane truck base Impinger 72.3 mppcf
#1500, BZ, at top of dust count
10 mg/m^
work ladder platform.
intended change
5 mg/sP
i
3-13-74 Main Receiving General BZ
dock
-
MSA color 15ppm
50 ppm
i
indicator
tube #47134,
carbon monoxide
3-13-74 3-13-74
15 Paint shop Near #7, paragraph 4 MSA aromatics 60ppo
East end
tu-be #-9-3-0-7-4
as toluene
100 ppm
15
i n
Draeger benzene tube #CH248
None or 25 ppm ceilinj less than value 25ppm
i'.mwf ."IlH>'!r
'A
Department areas and volumes(data from company).
De.pt # it
Bldg # 120
Sq. Ft. 72,560
Cu. ?t. 2,333,200
6
119
17,500
726,500
Cl
106
67,500
1,735,716
13 15
1, 55
(Paint shop)
'
-
( "
"
end 202)
( "
"
end 136) (receiving
174)
west east: dept
8120 9696 44,800
-
'
190,820
218,160
1,639,680
"he a.ame paint was used In areas tested 3-13-74, anil was reported '.o contain Zinc Chromate and Iron Oxide pigments, no Cadmium, and less chan 11 lead total in dried film.
. Department #1 haa spray painting over a dovn draft grill 32'x II ;;i need of maintenance. Air velocity was 0 - 5 0 fpra, excepting end end c o m e r areas where 150 fpa was found.
u The Tore ahold Limit Values refer to airborne concentrations of substances and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without verse effect. Because of wide variation in individual susceptibility, however, exposure of an occasional individual at or even below the threshold limit may not prevent discomfort, aggravation of a pre existing condition, or occupational illness.
0. This investigation was made in accordance with IC-5, Specific Sufetv Requirements of The Industrial Commission of Ohio Relating to All Workshops and Factories, and is net made in connection with any workmen/; compensation claim.
11, R e c c r a m e n d a t i o n s ;
A. For welding inside crane base #1500 off elevated platform, or similar locations, provide flexible duct local exhaust. If this cannot be done because of arc distortion, try natural drsft with s length of sterve pipe opening to room. If goo 3 air cannot be maintained to welder under these circumatanc:a, provide approved respiratory protection or limit time of eicposu
leas than TLV weighted average. This would be less than 12
minutes per hour relative to this dust count and equivalent (15 mppcf)of tentative value of 5 ~'g/M^ of Iron Oxide fume.
B. In Dep't 9 vhere paint spray carries into adjacent Dep't 3, limit spray tine to less than 4 hour* per day or provide respiratory protection to employees in near areas receiving spray. Preferably, provide paint areas enclosure with water curtain exhaust.
C. In East End of Dep't 15 (sample #7) Paint Shop, provide supplied , air respirator. Consider down draft ventilation as in dept 1
or enclosure of paint area including water curtain exhaust. 4a an alternative, H a l t spray time to 5 minutes per hour, with approved respirator system for both organic vapors and paint particles.
E. Provide maintenance for down draft ventilation in Dep't 1.
Very truly yours
Maurice E. Hatten, P.E. Industrial Hygiene Engineer