Document 6R4Y05KYem7yygB60595g3bNE

FILE NAME: Baldwin (BALD) DATE: 1974 Apr 3 DOC#: BALD023 DOCUMENT DESCRIPTION: Inspection Report - Clark Equipment Cov Lima Division The STATE OF OHIO ` In dustrial C ommission o f Ohio DIVISION O F SAFETY AND HYGIENE U 2 8 W EST FIFTH AVEN UE COLUM BUS, OHIO AS204 4H 41H IndMlrtsICvnmM m M o o n 1 STU B IN S Clwln-- a UARGUOHTK M. N tAL Vloa C M m JOHN E . SOW JOHN J. QIUJQAN DtvWon of BaM y w tf HysHwe SA irr s. bsymcm April 2, 1974 Mr. Earl Dundore Safety Director Clark Equipment Company . Lima Division, Box L 1046 S. Main St. Lima, Ohio 45802 Dear Mr. Dundore: Enclosed are two copies of a report on the visits made to your company on March 12 and 13, 1974. It vaa a pleasure to meet with you and other personnel and the courtesy extended was very much appreciated. If this Division can he of assistance to your company at any time on Industrial hygiene or engineering problems relating to safety, please let us know. 1 Very truly yours, "Maurice E. Hatten, P.E. Industrial Hygiene Engineer MEB:Jkp Left hearttfor OHIO for SAFETY The STATE OF OHIO * In dustrial C ommission o f Ohio DIVISION OF SAFETY AND HYGIENE U 28 w e a r n r r a a v k n u k COLUM 3U3. OHIO 43X04 433-3333 sxcaogrjunnwNt MAIKRJtMTt M. MKAL VtaaOMlmwi JOHN C. SO M JOHN J. GULUQAN Governor DtvMen of txtaty m < HysNM , OAKY S . SftYMOt SlWMmdMt April 3, 1974 CLASH EQUIPMENT COMPANY LIMA. DIVISION BOX L. 1046 S MAIN STREET LIMA, OHIO, 45802 1. On March 12 and 13, 1974, this company was visited in response to a company request for an industrial hygiene investigation. 2. Those contacted were: 3-12-74 Mr. Earl Dundore, Safety Director Mr. Robert Bromley, Personnel Manager Mr. Dennis Mault, Union Safety Comnitteeman Mr. James Holbrook, Electrician 3-13-74 Mr. Earl Dundore, Safety Director Mr. Robert Rowland, Safety Conmltteeaan Mr. Howard Kunkleman, General Foreman 3. The company manufactures very large cranes, draglines, back hoes, asphalt plants, and ocher heavy industrial equipment. 4. Sampling of shop dusts and other contaminants was done as outlined below: D a t e D e p '.t f B l d g . # S a m p le # Sample Location Found. mg/M3 TLV. mg/M3 3-12-74 5 120 1 Central aisle, colan 2.3 Iron Oxide 10 (5, intend; 5-B-22, BZ change) 3-12-74 6 119 2 6' from N, wall, (l Iron Oxide " eolmn 5-C-3 (Visual) rep laced by #5 3-13-74 9 106 3 10* NE of Column in 0.7 Oxide " WA 10, 7' from weld i operator, 6' from r> assemblyman, BZ . le ft hearIt for OHIO for SAFETY . n n n i Date Dep't # Bldg. # Sample # Sample Location Found. mg/M^ 3-13-74 3 Adjacent to 4 BZ, Central aisle, 0.15 Chromium 0.1 dept. 9 Paint about 30* from painting. Trioxide area(overspray) 4' above floor 3-13-74 6 119 5 BZ, Column 5-B-4, ,, 2.4 Iron Oxide (5,inten* about 50' from N change) wall, 1' above bench 3-13-74 13 Paint ship 6 BZ, several feet 0.10 Chromium 0.1 from operator, over Trioxide spray area. 3-13-74 15 Paint ship 7 BZ, about 2' above 2.7 Chromium East end floor, about 10' Trioxide from operator Method of Date Dep*t # Bldg. # Sample Location Sibling Pound TLV 3-12-74 5 120 Inside crane truck base Impinger 72.3 mppcf #1500, BZ, at top of dust count 10 mg/m^ work ladder platform. intended change 5 mg/sP i 3-13-74 Main Receiving General BZ dock - MSA color 15ppm 50 ppm i indicator tube #47134, carbon monoxide 3-13-74 3-13-74 15 Paint shop Near #7, paragraph 4 MSA aromatics 60ppo East end tu-be #-9-3-0-7-4 as toluene 100 ppm 15 i n Draeger benzene tube #CH248 None or 25 ppm ceilinj less than value 25ppm i'.mwf ."IlH>'!r 'A Department areas and volumes(data from company). De.pt # it Bldg # 120 Sq. Ft. 72,560 Cu. ?t. 2,333,200 6 119 17,500 726,500 Cl 106 67,500 1,735,716 13 15 1, 55 (Paint shop) ' - ( " " end 202) ( " " end 136) (receiving 174) west east: dept 8120 9696 44,800 - ' 190,820 218,160 1,639,680 "he a.ame paint was used In areas tested 3-13-74, anil was reported '.o contain Zinc Chromate and Iron Oxide pigments, no Cadmium, and less chan 11 lead total in dried film. . Department #1 haa spray painting over a dovn draft grill 32'x II ;;i need of maintenance. Air velocity was 0 - 5 0 fpra, excepting end end c o m e r areas where 150 fpa was found. u The Tore ahold Limit Values refer to airborne concentrations of substances and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without verse effect. Because of wide variation in individual susceptibility, however, exposure of an occasional individual at or even below the threshold limit may not prevent discomfort, aggravation of a pre existing condition, or occupational illness. 0. This investigation was made in accordance with IC-5, Specific Sufetv Requirements of The Industrial Commission of Ohio Relating to All Workshops and Factories, and is net made in connection with any workmen/; compensation claim. 11, R e c c r a m e n d a t i o n s ; A. For welding inside crane base #1500 off elevated platform, or similar locations, provide flexible duct local exhaust. If this cannot be done because of arc distortion, try natural drsft with s length of sterve pipe opening to room. If goo 3 air cannot be maintained to welder under these circumatanc:a, provide approved respiratory protection or limit time of eicposu leas than TLV weighted average. This would be less than 12 minutes per hour relative to this dust count and equivalent (15 mppcf)of tentative value of 5 ~'g/M^ of Iron Oxide fume. B. In Dep't 9 vhere paint spray carries into adjacent Dep't 3, limit spray tine to less than 4 hour* per day or provide respiratory protection to employees in near areas receiving spray. Preferably, provide paint areas enclosure with water curtain exhaust. C. In East End of Dep't 15 (sample #7) Paint Shop, provide supplied , air respirator. Consider down draft ventilation as in dept 1 or enclosure of paint area including water curtain exhaust. 4a an alternative, H a l t spray time to 5 minutes per hour, with approved respirator system for both organic vapors and paint particles. E. Provide maintenance for down draft ventilation in Dep't 1. Very truly yours Maurice E. Hatten, P.E. Industrial Hygiene Engineer E t end: TLV book . HGS Chronic Acid : K-05-B Lead Intoxication [ C Carbon Monoxide . D Spray coating [ E Iron, Fumes & Dust edd