Document 6R0dbOm2vOwgnMOmojJMo9bJo
664
CHAPTER 29
1955 Guide
Table 1. Unit Steam Consumption op Process Equipment*
Kitchen Appliances (exclusive op wateb heating)
Consumption Lb peb FIr
Pressure, PSIG
Stock and vegetable kettles (per 5 gal). Vegetable steamers (per compartment) Steam tables (per sq ft) Bain-Maries (per sq ft) Coffee urns (per gal)
Water urns (per gal) Soup' warmers (30 X 30 X 28 in.) Egg boilers (3 compartments) Clam, lobster, and potato steamers (per compartment) Oyster pots
Plate and cup warmers (per 20 cu ft) Food-warming ovens (per 20 cu ft) Silver burnisher and washers Dishwashers (per tray)
;
.20.0 40.0 1*7
' 3.4 3.4
5.0 100.0:
18.0 40.0 18.0
35.0 35.0 69.0 60.0
7-20 7-20 7-20 7-20 7-20
7-20 7-20 7-20 7-20 7-20
7-20 7-20 7-20 7-20
Laundry Equipment
Tumblers 40 X 94 in. 30 X 38 in.
Washers, (per gal water heated) Flatwork ironers,
100 to 120 in. chest type (per roll) 50 to 100 in. cylinder type (per machine)
Standard presses Large shirt body presses Cuff.and.neckband presses. Sleevers Steam-electric irons
Woolen pressing machines Large--electric vacuum Small--electric vacuum Large--steam vacuum Small--steam vacuum
Feather cleaning and sterilising 15 pillows per hr
-
360 225
1
60 60-120
105 190 .15.
12 '8
. . ..
25 12 35 20
175
100 100 15-100
100 100
100 100 - 100 100 .100
65 65 . 65 65
100
Hospital Equipment
Sterilisers, for bottles or pasteurisation (per bottle) Sterilisers, for water, (per gal) Sterilisers, for instruments and utensils,
8 X 9 X 18 in., water depth 3)4 in. 9 X 10 X 20 in., water depth 3)4 in. 10 X 12 X 22 in., water depth 4 in.
12 X 16 X 24 in., water depth 4 in. 10 X 12 X 36 in., water depth 4 in. 16 X 15 X 20 in., water depth 10 in. 20 X 20 X 24 in., water depth 24 in.
Sterilisers, for instruments @ 240-250 F, 12 X 20 in. 14 X 22 in. 16 X 24 in.
1 12
27 30 39
' :60 66 92 144
.
48 60 72
40 40
40 40 40
40 40 40 40
40 40 40
District Heating
665
Table 1. Unit Steam Consumption op Process Equipment (Concluded).
Hospital Equipment (continued)
Consumption, Lb per Hr
Pressure, PSIG
Sterilizers, for surgical supplies
10 X 20 in. 12 X 20 in. 14 X 22 in. 16 X 24 in. 16X36 in.
10 40 22 40 28 40 38 40 '54' 40
20 X 28 in. 20 X 36 in. 20 X 48 in. 20 X 60 in.
60 40 78' 40 98 40 124 ,40
Sterilizers, (autoclave) (240-250 F) 15.5 X 24 in. 17.5 X 26 in. 21.5X30 in. 24 X 36 in.
24 40 32 40 40 40 42 1 40-
Disinfector, mattress 30 X 42 X 84 in. 60 X 66 X 108 in.
Blanket warmers 18 X 24 X 72 in.
42 35-60 318 35-60
4 35-60
b district Heating Handbook {National District Healing Association, Third Edition, 1951). these values represent approximate requirements after warm-up period.
with high pressure are: (1) lower heat loss per square foot of pipe surface; (2) less trouble with traps and valves; (3) simpler problems in pressure reduction at the buildings; and (4) general reduction in maintenance'costs. With distribution pressures not exceeding 50 psig, there is less danger if the full distribution pressure should build up in the radiators or heaters through the faulty operation of pressure-regulating Valves: With pres sures higher than 50 psig, a second pressure-reducing valve or some form of emergency relief is required to preyent excessive pressures in the radiators or other heaters.-
The advantages of high-pressure distribution are: (1) smaller pipe sizes; (2) availability of the steam for various other operations requiring Higher pressures than the building heating system; and (3) wider flexibility in allowance for maximum pressure drop. Where distribution pressures
Table 2. Annual Steam Consumption . for Water Heating fob Various Types of Buildings, per Cu Ft of Volume* b
Type op Building
Consumption, Lb/(Yr)(Cu Ft)
.
Consumption Lb/(Yb) (Cu Ft)(100 F deg
Temp. Rise op Water)
Hotel Residence Club Apartment House Department Store Office Theatre
Parking Garage
3.20 2.56 -2.41 0.95 0.85 0.67 0.46
,
2.66 2.11 . 1.99 0.79 0.71 0.48 0.38
* t>_ j
--
1
...
..
ia analysis by fourteen district heating companies from metered consumptions. Building volume 6 vj^^ate gross volume.
ora District Heating Handbook (National District Heating Association, Third Edition, 1951, p. 347).