Document 6R0dbOm2vOwgnMOmojJMo9bJo

664 CHAPTER 29 1955 Guide Table 1. Unit Steam Consumption op Process Equipment* Kitchen Appliances (exclusive op wateb heating) Consumption Lb peb FIr Pressure, PSIG Stock and vegetable kettles (per 5 gal). Vegetable steamers (per compartment) Steam tables (per sq ft) Bain-Maries (per sq ft) Coffee urns (per gal) Water urns (per gal) Soup' warmers (30 X 30 X 28 in.) Egg boilers (3 compartments) Clam, lobster, and potato steamers (per compartment) Oyster pots Plate and cup warmers (per 20 cu ft) Food-warming ovens (per 20 cu ft) Silver burnisher and washers Dishwashers (per tray) ; .20.0 40.0 1*7 ' 3.4 3.4 5.0 100.0: 18.0 40.0 18.0 35.0 35.0 69.0 60.0 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 7-20 Laundry Equipment Tumblers 40 X 94 in. 30 X 38 in. Washers, (per gal water heated) Flatwork ironers, 100 to 120 in. chest type (per roll) 50 to 100 in. cylinder type (per machine) Standard presses Large shirt body presses Cuff.and.neckband presses. Sleevers Steam-electric irons Woolen pressing machines Large--electric vacuum Small--electric vacuum Large--steam vacuum Small--steam vacuum Feather cleaning and sterilising 15 pillows per hr - 360 225 1 60 60-120 105 190 .15. 12 '8 . . .. 25 12 35 20 175 100 100 15-100 100 100 100 100 - 100 100 .100 65 65 . 65 65 100 Hospital Equipment Sterilisers, for bottles or pasteurisation (per bottle) Sterilisers, for water, (per gal) Sterilisers, for instruments and utensils, 8 X 9 X 18 in., water depth 3)4 in. 9 X 10 X 20 in., water depth 3)4 in. 10 X 12 X 22 in., water depth 4 in. 12 X 16 X 24 in., water depth 4 in. 10 X 12 X 36 in., water depth 4 in. 16 X 15 X 20 in., water depth 10 in. 20 X 20 X 24 in., water depth 24 in. Sterilisers, for instruments @ 240-250 F, 12 X 20 in. 14 X 22 in. 16 X 24 in. 1 12 27 30 39 ' :60 66 92 144 . 48 60 72 40 40 40 40 40 40 40 40 40 40 40 40 District Heating 665 Table 1. Unit Steam Consumption op Process Equipment (Concluded). Hospital Equipment (continued) Consumption, Lb per Hr Pressure, PSIG Sterilizers, for surgical supplies 10 X 20 in. 12 X 20 in. 14 X 22 in. 16 X 24 in. 16X36 in. 10 40 22 40 28 40 38 40 '54' 40 20 X 28 in. 20 X 36 in. 20 X 48 in. 20 X 60 in. 60 40 78' 40 98 40 124 ,40 Sterilizers, (autoclave) (240-250 F) 15.5 X 24 in. 17.5 X 26 in. 21.5X30 in. 24 X 36 in. 24 40 32 40 40 40 42 1 40- Disinfector, mattress 30 X 42 X 84 in. 60 X 66 X 108 in. Blanket warmers 18 X 24 X 72 in. 42 35-60 318 35-60 4 35-60 b district Heating Handbook {National District Healing Association, Third Edition, 1951). these values represent approximate requirements after warm-up period. with high pressure are: (1) lower heat loss per square foot of pipe surface; (2) less trouble with traps and valves; (3) simpler problems in pressure reduction at the buildings; and (4) general reduction in maintenance'costs. With distribution pressures not exceeding 50 psig, there is less danger if the full distribution pressure should build up in the radiators or heaters through the faulty operation of pressure-regulating Valves: With pres sures higher than 50 psig, a second pressure-reducing valve or some form of emergency relief is required to preyent excessive pressures in the radiators or other heaters.- The advantages of high-pressure distribution are: (1) smaller pipe sizes; (2) availability of the steam for various other operations requiring Higher pressures than the building heating system; and (3) wider flexibility in allowance for maximum pressure drop. Where distribution pressures Table 2. Annual Steam Consumption . for Water Heating fob Various Types of Buildings, per Cu Ft of Volume* b Type op Building Consumption, Lb/(Yr)(Cu Ft) . Consumption Lb/(Yb) (Cu Ft)(100 F deg Temp. Rise op Water) Hotel Residence Club Apartment House Department Store Office Theatre Parking Garage 3.20 2.56 -2.41 0.95 0.85 0.67 0.46 , 2.66 2.11 . 1.99 0.79 0.71 0.48 0.38 * t>_ j -- 1 ... .. ia analysis by fourteen district heating companies from metered consumptions. Building volume 6 vj^^ate gross volume. ora District Heating Handbook (National District Heating Association, Third Edition, 1951, p. 347).