Document 6KBZRmBbkZQ3wpoQv1BKZxY1

i tj February 27,1992 Dow U.S.A The Dow Chemical Company P 0 Box 150 Plaauemine. Louisiana TOTGS-O'SO Daniel Cortez Petrin Building 4106 cc: Rodney Bordelon Methanes Building 4601 Asbestos Monitoring Enclosed is the correct copy for the sample #13482 on 1-30-91. Please attached this letter and corrected copy to the original letter dated February 19, 1992. Thank you, Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc PRODUCED FOR THE ASBESTOS DATABASE DATE: ^ --i Q , , MASTER No------- - DO A 114757 CONTIDFNTTAL **LOD ***LOQ 8-HR. TWA LIMIT-0.20 FIB/CC 30-MINUTE UMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 ASBESTOS MONITORING DATA RESULTS: METHANES 1992 ) I DATE SAMPLE# PERSONNEL DESCRIPTION 1/30/92 13482 *437-21-3070 Insulator: Wet method used while removing 4' x 8' sheets of transits 1/30/92 13483 *435-06-2532 Insulator: Wet removal method used white taking down transits sheets 4' x 8* DURfMIN) 30 VOL(L) 57 ** LOD FIB/CC <0.01 ***LOQ EIEUCC <0.68 30 76 <0.03 <0.51 * The proper protective clothing was worn during die fob. North 7700 Flespirator with HEPA filters were worn during the fob. Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical melhod 7400, the stated range of the method Is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this Information, we will establish 100 Fibers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 litter area as our Limit of Detection (which is more representative of the actual fibers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. D A 114750 conftdfnjttal pcPETRI'N P. O. Box 330 Port Allen, LA 70767 Louisiana Contractor's License #733-1 CORPORATION TO: RE: FROM: DATE: DARLENE S. CREEL LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD # 13482 EDDIE GUILLORY 2-25-92 MS. CREEL, WE REGRET THAT AN ERROR WAS MADE CONCERNING THE EMPLOYEE I.D. NUMBER FOR STEVE FONDREN ON 1-30-92 FROM THE ABOVE REFERENCE. PLEASE FIND ATTACHED THE CORRECTED INFORMATION THAT YOU REQUESTED. IF ANY OTHER QUESTIONS ARISE, FEEL FREE TO CONTACT MYSELF OR DANIEL CORTEZ, ASBESTOS SUPERVISOR AT EXT. 6300- THANK YOU FOR YOUR COOPERATION REGARDING THIS MATTER. EDDIE GUILLORY PETRIN CORPORATION EXT 6300 BLDG 4106 ATTACHMENT eh OO A 1,14759 CONFIDENTIAL 1405 Commercial Drive Port Allen, Louisiana 70767 Phone (504) 343-0471 Ip: - VivCl.'" *' S.-;- :,, ;. jr * c. - ct:^' *fr /'Y-.y - t- 1 LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD PLANT/DEPT. MONITORING FOR: f DATE A C? OTHER CHEMICALS PRESENT:. SAMPLE N" 1 6 4 b L SAMPLE COLLECTION MEDIA BADGE NO. TYPE TEMP/HUMIDITY: (REQUIRED FOR BADGES), O CHARCOAL TUBE SIZE_________________ ^FILTER CASSETTE SIZE g-5~ O SILICA TUBE SIZE__________________ DRAGERTUBE TYPE_________________ PUMP SERIAL NO.. ST!23CALIBRATION DEVICE: S^UBBLEMETER OTHER_______ PUMP FLOW RATE CALIBRATION: BEGIN: '> 2Zm$s: ROTAMETER 7 OTHER __________________________________ SHIFT: ^HR. 12 HR. c PERSONNEL SAMPLE AREA SAMPLE FUU SHIFT TWA STEL/TASK BEGINNING FLOW RATE AVG.*J_U$ ^ ENDING: 1. lO ft? 2../_Z_fr7- 3-> n- j ENDING FLOW RATE AVG. /Jft? HKCC/MIN L/MIN /V ^ S^CC/MIN L/MIN EMPLOYEE NAME EMPLOYEE I.D JOB CLASSIcFhIC-aAtTiI^ONm -7r^"..-- IH JOB CODE * CONTRACTOR COMPANY. ^; x ^ > 7-2J- TQ7/fV SSAample average flow rate 1 TIME STARTED. 9 :jrsr TIME STOPPED. TOT. RUNNING TlKSE(MIN) Z?/? } RESPIRATOR USED? O-YtS NO RESPIRATOR MODEL / CANISTER TYPE 7U&5C T7 00 /%L SAMPLE VOLUME (AVG FLOW X RUN TIME) MOUTH-BIT DUST S-'HALF-FACE O FULL-FACE AIR-LINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING . ^j /? ^ ^ ___ & ''jC jtF ANALYTICAL REPORT REFERENCE # ANALYTICAL RESULTS. ________c LOfxrt * RESTRICTED FOR USE WITHIN DOW ONLY * _ /O' ____ ' loO v)'' 24 j), (j& u FORM FILLED IN BY: DO r-i 114-/OU C,, OOF T i^FD i T AL ASBESTOS MONITORING DATA RESULTS^METHANES 1B92 **LOD ***LOQ EXPOSURE GUIDELINES e-HR. TWA LIMIT - 0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE* PERSONNEL DESCRIPTION r^ DUBININ} VQUU 1/30/92 13482 *407-06-gS02 Insulator: Wet method used while removing 4* x 8' sheets of transite 30 57 1/30/92 13483 *435-06-2532 Insulator: Wet removal method used while taking down transite sheets 4* x 8* 30 76 * The proper protective etching was worn during the |ob. North 7700 Respirator with HEPA filters were worn during the fob. ** LOD FIB/CC <0.01 <0.03 ***LOQ E1B/CC <0.68 <0.51 Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method Is 100 to 1300 Flbers/MM2 filter area. Although samples below this range can be analyzed, the method has net been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this Information, we will establish 100 Flbers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 fitter area as our Limit of Detection (which Is more representative of the actual libers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute tlm weighted average short term sample at a flow rate of 2 liters per minute. I | FiJ A 1 i 4 701 confidential