Document 6EEJanG66OKEj6QrdrxMkemE

I INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION technical center P.D. BOX Q361, SOUTH CHARLESTON. WV 25303 To Ifsleme) Oiv*ja*on Location Area A. F. Terry 704 511 Copy CD -- C. P. Maxwell - 701/2 G. D. McClure - 704/2 R. G. Rowe, M.D. - 791 H. E. Rucker - 512/2009 C. L. Ruddle - 704/2 R. E. Sergent - 704 Date Originating Dept. Area Subiecr. February 5, 1987 EM&TS - HS&EA Industrial Hygiene Asbestos Exposure Monitorinq - Non Abatement Attached are the results of the Asbestos exposure monitoring performed on P. K. Snodgrass on January 21, 1987. He was monitored while installing a metal vapor barrier on steam lines containing Asbestos insulation, in the basement of the 704 Powerhouse. He was equipped with an AOR57-A half-face HEPA cartridge respirator and two pair of coveralls, the outer being disposable. The exposure monitoring results indicate that the levels, for this non-abatement job, were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWAg). However, we recommend that the insulators continue to follow closely the established procedures for this type of work. We plan more monitoring upon notification from you that this job has been resumed. Please notify P. K. Snodgrass of his exposure monitoring results as soon as possible. Please have him sign and date this report and return to M. A. Patel at Building 701-330. If we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK BY: APPROVED BY: Vance E. Stover Attachment VES:MAP:rab 2087P r^owJL^ X. Manhar A. Patel UCC 024811 ASBESTOS EXPOSURE MONITORINS Carp ref. W2118 Date 1-21-87 1-21-87 Sanple Type/ Personnel Name Sanpling Time Personal/ P. K. Snodgrass 7 hrs 14 min Air Cone Fiber/cc 0.0071 iwe Fiber/cc 0.0064 OOttEKTS Collected while installing vapor barrier on steam lines containing Asbestos insulation. Area 7 hrs 9 nrin 0.005 - Collected near the No. 3 boiler - 704 1st level - in the area where the powerhouse operators spend most of their time. ASBESTOS Permissible Exposure Level TWg 0.2 fiber/cc OSHA Action Level 0.1 fiber/cc 2087P UCC 024812