Document 6BmywK94N8Vv6O66EBj3nLp54
A, v ">
UNITED STATES GYPSUM COMPANY
/_1000 East Northwest Highway/Oes Plaines, Illinois 60016 ApfAcooe 3tt crpness 9-33ai
*ikr
December 7, 1979
Mr. George T. Causey Director of Physical Plant. Loyola College of Maryland 4501 North Charles Street Baltimore, MD 21210
. '
!
.*
Dear Mr. Causey:
.
This is in response to your letter of December 4, 1979, requesting
information on SABINITE Acoustical Plaster. Although we have no
samples or other confirmation that the United States Gypsum Company
' product, SABINITE Acoustical Plaster, was actually used in your' ..
building at Loyola College, we submit the following information
to assist you.
'
SABINITE Acoustical Plaster consists primarily of gypsum plaster, an aggregate (pumice or expanded perlite), wood and/or paper fiber, and a foaming agent which together total approximately 93 to 957.. .
SABINITE Acoustical Plaster contains only a minor amount of asbestos, approximately 5 to-7%. The asbestos is added to provide body to the * wet mortar, thereby reducing the tendency of the mortar to sag and
flow when applied to the ceiling. The small amount of asbestos fiber is securely embedded in the mortar matrix and should not be released to the air unless it is forcefully pulverised or abraded.
I am not aware of, nor can X conceive of, a hazardous exposure result
from_a properly installed and maintained SABINITE Acoustical'Plaster
_ ceiling. However, if there is concern about the surface, for whateve
' reason, I would suggest that the ceiling be painted, if it has not
been painted in the past.
-
We recommend a thin, spray-applied coat of vinyl latex ceiling flat paint such as USG TEXOLITE Standard, appropriately thinned for spray application. The paint must be a permeable type, rather than a scale or a bridging type. A heavy coat of paint, or numerous applications of paint, will obviously impair the acoustical efficiency of Acoustic Plaster.
*
Use a slow, uniform motion. Cover surface in one pass. Do not pass over the sdme area several times, as this builds up paint unnecessari
:rge T. Causey College of Maryland
December 7, 1979 Page Two
at least overnight drying between coats. vBrush or roller painting
recommended.
'
your opinion, the "flaking" which you reported in our phone sation could not be adequately coated or encapsulated by painting, .d recommend the use of a vacuum cleaner equipped with a hose and : brush. Do not use a stiff brush, and _o not scrub or abrade the :e of the plaster. Workmen should be provided with a respirator cified by OSHA. Regulations in 29 CFR 1910.1001. Disposal of ; must be made in impermeable containers to designated disposal
st this information serves your needs. If you require further ration, please feel free to contact the writer. *
rely.
th S. Freeman, Manager ner Product Safety rch and Development
692