Document 6Bd7akYrRB7n20n1d72kQZZ63

466 CHAPTER 20 1954 Guide1'. Table 2 Return Air Duct System Combination of Parts Selected as Standard / ' Combi nation , No. 1 51 52 53 54 ] Iettjhn-Aib Intake Size, In. Basb-^ Board Floor* EUseb Size, In. Where Stack is Used in Stud Space 23 4 10 x 6 6 X 10 10 x 3i" or 4 x 14 10 x 6 6 x 10 10 x 31" or 4 x 14 12 x 6 6 x 12 12 x 31" or 6 x 14 14 x 6 6 x 14 14 x 3Jd Branch Pipe Size, In. * Round ^ctGEUCLT.AANR*- Required When Joist Lining [ncbsasb in IS USBDb'. - ` 7 ,, ! Width op . 8 ;Number op Joist Spaces Lined' and .. 'bunk Duct (fob In. > Minimum Depth op , `Space Required Duct), In. 56 7 . 8 6 4x8 a space of 3 in. depth 1. 6 4x8 1 space of 3 in. depth 2 7 5x8 1 space of 4 in. 3 depth 8 65-x 8 1 space of 5 in. depth 4,- 55 24 x 6 6 x 30 Two or stacks 30 x 6 each 10 x 3ic 56 30 x 6 6 x 30 Two stacks 12 x 3}d 57 -- 8 x 30 9 8 x 8 1 space of 6 in. depth or 2 spaces of 3 in. depth* 10 ,10 x 8 1 space of 7 in. depth or 2 spaces of 4 in. depth 12 15 x 8 1 space of 9 in. depth or 2 space.3 ....of 5 in. depth 57-' 12 Slid iuwu vu>>u>w"<4 _______________________w blinkdBbaosxeeds oisn s1u4gigse.sstpeadc. e between joists. Use full depth of joist, except when joist depth is less than suin' mutn depth required, in which case a drop pan must he used. This may occur when two or more retum ducto are ccIofninteicsteddestioretdhetosuasmee14joiins.txsp3afcien.'. stud space, it makes no difference whether this space hag protrud** keyds Iofrint oist.desired to use 14 in. x 3} in. stud space, the pla' sVte"r base must be smooth, without any protrudicj plaster keys to interfere with the flow of air. ^. 2. Location of registers and return intakes on floor plan, showing types of registers, with distance from register to opposite wall and deflection of registers desired. 3. Laying out a proposed duct system for both warm air and return air sides of the system, and including details of types of fittings and the actual and equivalent lengths of each branch line from bonnet to register, without sizes. (See Fig- *> Groups 1 through 6, for equivalent length of fittings.) 4. Determination of bonnet temperature. If rating sheet for furnace-blower unit specifies a Jized value of bonnet tempero^.8' enter table at this value. If not specified, use the following procedure: Use'TaW* 5 for buildings having a heat loss between 120,000 and 350,000 Btu per hr or Table for buildings having a heat loss greater than 350,000 Btu per hr. Select shortest length and read downward in nearest column in Tables 5 or 6 until lower heavy <hag ' nal line is reached, but do not cross line. Run horizontally to first column of t*P . and note bonnet temperature: Also select longest'actual lenqih and read dowhwa^ in nearest column in Tables 5 or 6, until upper heavy diagonal line is just crosse Forced Warm Air Systems 467 Run horizontally to left to obtain value for bonnet temperature in first column. Se lect as the design bonnet temperature any value between these two limits. res5p.eDcteivteerrmeginisatetior nairofteamirpevroaltuumrees.to be delivered through each register and the Using Tables 5 or 6 and the design bonnet temperature selected, find the values of e/m per 1000 Btu for each duct length, and the corresponding register temperature. the6.aiSrevleoclutimonesohf arengdilsetde.r sizes and. pressure losses to produce necessary throw, for Use Tables 7 or 8 to obtain required free area and pressure loss of register. 7. Design pf duct system. A. Warm air branches. : a. Use Table 9 to select maximum bonnet pressure usually required for thb trunk carrying the maximum volume of air (cfm). If the maximum bonnet pressure is not high enough to accommodate the pressure loss through the registers, use a higher bonnet pressure. If the register pre- ` sure is critically large, it may be necessary to reduce it by either using two registers in place of one, or using smaller deflection angles. ; b. Obtain actual duct loss by subtracting total register pressure loss, as I determined from Tables 7 or 8, from maximum bonnet pressure. ) c. Obtain the pressure drop in each duct per 100 ft by use of Table 10. 1 i d. Determine duct size by means of air friction chart (such as Fig. l, Chapter 32), volume.(cfm), and pressure drop per 100 ft of duct. B. Return air branches. a. Select a low value of actual duct loss obtained from step b under item A for the suction loss of return duct system. ; b. Proceed in sizing return air branches by the same method described for the warm air branches. C. Trunk ducts for warm air and return air sides of system. j a: Add air volumes of branches to be handled by each trunk duct. ;, b. The friction loss per 100 ft of trunk duct is determined by taking the sthmeajlulenrcotifotnh.e two values for friction loss for the two ducts meeting at ....... e. Determine trunk duct size by using an air friction chart, volume (cfm)> 'and pressure drop per 100 ft of trunk duct. 8. Selection of Blower. ;; A. Determine total cfm air delivery (the sum of all branch cfm values). B. Determine static pressure requirement. ' a. For furnace-blower combination units it is the sum of bonnet pressure and suction pressure. - b. For blowers separately selected from the furnace it is the sum of bonnet . pressure, suction pressure, filter loss, casing loss, losses through air washers, coils, and other devices. 9. Selection of Furnace. A. Determine register delivery (the sum of room Btu losses). B. Determine bonnet capacity. Bonnet capacity-- (total cfm) X (temperature rise) X 1.089. C. Determine allowance for pick-up load. For buildings which are heated in termittently, such as churches and auditoriums, it is customary to add from 10 to 25 percent extra furnace capacity for warming of the structure. AUTOMATIC CONTROLS Air stratification, high bonnet temperatures, excessive flue gas temperaHre?> and heat overrun or lag in a properly designed system, can be largely ? `ounated through proper care in the planning and installation of the conr system;26 *3d4e*sirable controls usually employed are: b A thermostat located in occupied spaceivhere maximum fluctuation in tempera-