Document 69qOzm4eKb1apGNqoJ42dXVE

bO SUNBEAM GRAVITY FURNACES WINTER AIR CONDITIONERS Price Book SE-4 SEPTEMBER 26, 1949 NOTICE The Trade Prices shoicn herein do not include freight or cartage Page . GENERAL TERMS.................................................. 2 FURNACE SELECTION INFORMATION.............. 3 SUNBEAM GRAVITY FURNACES........................ 4-8 i SUNBEAM FLOOR FURNACES............................. 9 SUNBEAM WINTER AIR CONDITIONERS.......... 10-16 ARCOFLAME OIL BURNERS,;............................... 17-18 SUNBEAM BLOWER-FILTER UNITS.................... 19 AIR FILTERS............................................................. 19 ,, HUMIDIFYING EQUIPMENT.................................. 20 TEMPERATURE CONTROL EQUIPMENT...... . 21 'J GAS WATER HEATERS...................... 22' American c^taudand Radiator ^^aiiitai^ CORPORATION Pittsburgh 30, Pm, 03655 General Terms AMERiCAN-c^tacdatfd heajuig iquipmekt General Terms ' Illustrations and descriptions of Plate Numbers listed in the price book will be found in the Warm Air Heating Equipment Section of the "AMERICAN-STANDARD" GENERAL CATALOGUE. Items illustrated in the GENERAL CATALOGUE and not included in this price book are discontinued. Items added since the issuance of the last Catalogue Revision are described for identification! ' . PRICES All prices herein quoted supersede all prior quotations and are subject to change with out notice. :. No obligation is assumed by this Corporation to sell to any one holding this book any of the items listed herein at the prices stated, i. . A minimum invoice charge of forty-five cents (.45) will apply on any item including re pair parts. TAXES To the prices and terms quoted add any Manufacturers' or Sales Tax payable on the transaction under any effective statute. .. . ,. TRANSPORTATION CLAIMS The responsibility of this Corporation ceases upon delivery of goods in good order to transportation companies, and all goods are shipped at consignees' risk. _ ORDERS The Corporation shall not be liable for any delay or failure in the delivery or shipment of products or for any damages suffered by reason of such delay or failure, when such delay or failure is, directly or indirectly, due to fire, flood, accidents, riots, war, embargo, labor stoppages, inadequate transportation facilities, shortage of material or supplies, regulation by Governmental authority, or any cause or causes beyond this Corporation's control. - - GUARANTEE We guarantee goods manufactured by this Corporation to the extent that we shall fur nish by freight new articles or parts for any articles or parts of such goods found defective in workmanship or material within one year after installation. - - In all claims, no labor or other consequential damages shall be allowed. Goods of other manufacturers sold by us are not guaranteed by this Corporation. CLAIMS No claims under the above guarantee, or for variances from or shortages in orders will be allowed, unless presented within sixty (60) days after receipt of goods. _ SPECIAL PRODUCTS Items of special nature or products requiring special manufacture or supervision are not subject to change or cancellation after production is started. RETURNED GOODS Good material of standard manufacture must not be returned for crec it without first securing written permission, and when so returned will be subject to a deduction of 10% for re-handling, and all transportation charges, including freight and cartage, will be paid by shipper. * . Materials made on special order are not subject to return. SHIPPING WEIGHTS Weights are for customers' convenience only, are approximate and not guaranteed. SE-4 2 Freight Conditions applying to Price Book SE-4 AMERiCAN-c$tandard SUNBEAM WARM AIR HEAT1NQ EQUIPMENT September 26,1949 FREIGHT ALLOWANCES All previous freight allowances are void. SHIPMENTS OF AMEWCAN-^andard WARM AIR HEATING EQUIPMENT INCLUDING SUNBEAM GRAVITY FURNACES, WINTER AIR CONDITIONERS, FLOOR FURNACES, BLOWER-FILTER UNITS, ARCOFLAME OIL BURNERS AND CONTROLS, AND (HUMIDIFIERS, CONTROLS AND ACCESSORIES WHEN SHIPPED WITH COMPLETE UNITS) ARE: F.o.b. Factory with the rail carload rata of freight allowed as maximum on shipments of 200 pounds or more; this allowance not to exceed the lowest volume rate. No freight allowance will be made on shipments of less than 200 pounds. In no case is this allowance to be in excess of the actual freight paid. No freight allowance will be made on shipments of Repair Parts or on shipments of Humidifiers, Controls and Accessories when shipped separately. AIR FILTERS FOR REPLACEMENT Shipments of twelve (12) or more Air Filters are f.o.b. Factory with rail freight up to the amount of $2.86 per hundred pounds allowed. WATER HEATERS Shipments of Water Heaters are f.o.b. Factory with the rail carload rate of freight allowed as maximum on shipments of 200 pounds or more; this allowance not to exceed the lowest volume rate. No freight allowance will be made on shipments of less than 200 pounds. In no case is this allowance to be in excess of the actual freight paid. No freight allowance will be made on shipments of Water Heater Repair Parts. On orders for shipment to any point not in the 48 United States, or the District of Columbia, freight allowances will be those applicable to the port of export only. Above allowances will not include any additional charges not included in road haul rates for services performed by carrier at destination, such as detention of carrier's equipment, redeliveries, etc. Any such additional charges will be for account of the wholesale distributor. We reserve the choice of transportation facilities and shipping point. Freight allowances are subject to change without notice. A urmr<> ^4-r+%An+*A CORPORATION Pittsburgh 30, Pa. 03657 Furnace Selection Information j^MEEIcjuj-^tflPdflfd heatiboeqcipmsit Furnace Selection Information Converting Requirements in Square Inches to Btu Capacities at Registers Square Inch Ratings shown for all Sunbeam Gravity Furnaces are based on approximately one-half of capacity being supplied to first floor and one-half to second floor. For conditions where entire demand is all on one floor, or is substantially greater on one floor than the other, convert the square inch requirements of the installation into Btu by the following method: Multiply square inch requirements of first floor by 111; Multiply square inch requirements of second floor by 167; Add the results and select Furnace having Btu capacity at register equal to or greater than the total. Examples: 1. Assume one story building requires 675 square inches of leader pipe: 675 x 111 = 74,925 Btu at registers 2. Assume two story building with furnace heating only second floor requires 390 square inches of leader pipe: 390 x 167 = 65,130 Btu at registers 3. Assume two story building requires 565 square inches of leader pipe on first floor, and 185 square inches on second floor: , 565 x 111 = 62,715 Btu at registers -- first floor 185 x 167 = 30,895 Btu at registers -- second floor 93,610 Total Btu at registers Ratings Square Inch Ratings are calculated by dividing the Btu Capacity at Registers by 136. Btu Capacity at Registers for all Sunbeam Gravity Furnaces is 75% of Btu Capacity at Bonnet. ... Btu Capacity at Registers for all Sunbeam Winter Air Conditioners is 85% of Btu Capacity at Bonnet. 3 SE-4 r i 03658 Hand Fired AMHUCAN-<$tAttda*d HEATING EQUIPMENT Sunbeam Furnaces SUNBEAM HAND FIRED FURNACES CAST IRON Catalogue Page SI-6 KENWOOD Cast Iron Pipe Furnace Furnace Number Diam. Fire Pot Btu ItRating Capacity Square at Inches Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Shipping Weight A-1018-CD A-1040-CD A-10+4-CD A-1048-CD A-1052-CD 18' 20' 22' 24' 26' 390 53,000 8 92.00 699 $ 6.00 467 63,500 99.50 835 10.50 637 73,000 111.50 965 12.50 597 81,260 125.00 1076 14.00 683 92,900 152.00 1376 . 17,00 56 $100.00 755 68 110.00 903 74 124.00 1039 60 139.00 1156 92 169.00 1468 STANDARD EQUIPMENT--Check draft, finishing collars, Vapor pan, poker, draft regulator, chain and pulleys, asbestos cement, nuts and bolts. NOTE: Cone type hoods are regularly furnished. Flat top or one pipe type hoods furnished when ordered without extra charge. ttSEE PAGE 3--`''CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS/' KENWOOD Cast Iron Pipeless Furnace Furnace Number Diameter Fire Pot Btu Capacity Trade Prices Complete Approximate Shipping Weight A-1018-BD A-1040-BD A-1044-BD A-1048-BD A-1052-BD 18' 20' 22' 24' 26' 70,700 84,700 97,300 108,100 123,800 $124.00 144.00 167.00 189.00 216.00 916 1121 1266 1410 1737 STANDARD EQUIPMENT--Register, check draft, vapor pan, poker, draft regulator, chain and pulleys, asbestos cement, nuts and bolts, warm-air and return-air extensions. NOTE: Duplex Crete* are regularly furnished with Kenwood Pipe and Pipeless Furnaces. Triangular Grates are available at no additional charge; when ordered, specify with suffixes "CT" or "BT,"' instead of "CD" or "BD," respectively. ARLINGTON Steel Pipeless Furnace Furnace Number Diameter Shell Btu Capacity Trade Prices Complete Approximate Shipping Weight BD-520 8D-522 BD-524 BD-527 20' 22' 24' 27' 90,500 112,800 126,200 134,500 $151 .00 177.00 207.00 239.00 1102 1157 1255 1369 STANDARD EQUIPMENT--Register, check draft, vapor pan, poker, draft regulator, chain and pulleys, asbestos cement, nuts and bolts, warm-air and return-air extensions. SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR TEMPERATURE CONTROL EQUIP* MENT. NOTE: Deduct 5% from price of Cast Iron or Steel Furnaea Only, respectively, for omission of Grate Assembly, Ashpit Door, and Hand Firing Accessories. SE-4 4 03659 Sunbeam Furnaces AMERlCAN-c$Uttd(awi heatiic equipmext Hand rired Furnace Number SUNBEAM HAND FIRED FURNACES ARLINGTON Steel Pipe Furnace Catalogue Page S7-10 GALVANIZED BOUND CASING Diam. Shell Btu ttRating Capscity Square at Inches Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing end Hood Trade Prices Approx. Shipping Weight 0-520 20' 499 67,600 6 96.00 609 012.00 70 0110.00 879 D-522 22' 622 64,600 115.20 656 13.80 75 129.00 931 D-524 24' 696 94,600 136.40 921 15.60 77 152.00 998 0-527 27' 741 100,000 168.30 1021 17.70 81 186.00 1102 STANDARD EQUIPMENT--Check draft, finishing collars, vapor pan, poker, draft regulator, chain and pulleys, nuts and bolts. Furnace Number CLIFTON Steel Pipe Furnace Catalogue Page S13-15,17 GALVANIZED ROUND CASING Diam. Shell Btu ttRating Capacity Square at Inches Registers Furnace Only Casing and Hood Furnace with Casing and Hood Approx. Approx. Approx. Trade Shipping Trade Shipping Trade Shipping Prices Weight Prices Weight Prices Weight D-0030 30' 943 128,200 0225.50 1375 021.50 101 0247.00 1476 C-6034 34' 1,024 139,300 300.50 ,1553 24.50 113 325.00 1666 STANDARD EQUIPMENT--Check draft, finishing collars, vapor pan, poker, drift regulator, chain and pulleys, nuts and bolts. Smoke Teos for Clifton Steel rurneeee: 10*--44.00 Trade Price Furnace Number ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page S11-12 ____________SQUARE METAL JACKET___________ Diameter Shell ttRating Square Inches Btu Capacity at Registers Furnace With Square Jacket and Fla t Hood Trade Prices Approx. Shipping Weight 0-520-SQ D-522-SQ D-524-SO 0-527-SQ 20' 22' 24' 27' 499 67,800 0120.00 622 84,600 142.00 696 94,600 162.00 741 100,800 197.00 1059 1115 1205 1317 STANDARD EQUIPMENT--Square Metal Jacket with inner liner, check draft, finishing collan, poker. draft regulator, chain and pulleys, nuts and bolts. --- ~ '' NOTE: Deduct 5% from price of Furneeo Only for omission of Grate Assembly, Ashpit Door, and Hand Firing Accessories. NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered without extra charge. The Arlington "Square" Model is furnished only with straight side flat top hood which is a part of the jacket. ftSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO 8TU CAPACITIES AT. REGISTERS SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 2t FOR TEMPERATURE CONTROL EQUIPMENT, 5 SE-4 Oil Fired AMEHICAN-C$tattdai heating equipment Sunbeam Furnaces Furnace Number SUNBEAM OIL FIRED FURNACES ARLINGTON Steel Pipe Furnace Catalogue Page S7-10 GALVANIZED ROUND CASINO ft Btu Diam. #Rating Capacity Shell Square at Inches Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Shipping Weight D-520-G or R D-522-G or R D-524-G or R D-527-G or R 20' 22' 24' 27' 596 61,000 6 96.00 601 912.00 622 84.600 115.20 627 13.60 696 94,600 136.40 656 15.60 741 100,600 166.30 730 17.70 70 9110.00 671 75 129.00 702 77 152.00 733 61 186.00 811 STANDARD EQUIPMENT--Finishing collars, vapor pan, nuts and bolts. Furnace Number CLIFTON Steel Pipe Furnace Catalogue Page SI 3-17 GALVANIZED ROUND CASING tt Btu Diam. Rating Capacity Shell Square at Inches Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Shipping Weight D-6030-G or R 30' C-8034-G or R 34' 943 126,200 9225.50 1024 139,300 300.50 946 1057 921.50 24.50 101 9247.00 1049 113 325.00 1170 Smoko Toot for Clifton Stool Fumaeos: 10'--$4.00 Trade Price STANDARD EQUIPMENT--Finishing collars, vapor pan, nuts and bolts. Furnace Number ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page S11-12 ____________SQUARE METAL JACKET_________ Diam. Shell tt Rating Square Inches Btu Capacity at Registers Furnace with Square Jacket and FU t Hood Trade Prices Approx. Shipping Weight D-520-SOG or SC)R D-522-SOQ or S< >R D-524-SQG or SC >R D-527-SQG or $() R 20' 22' 24' 27' 596 81,000 9120.00 863 622 84,600 142.00 916 696 94,600 162.00 978 741 100,600 197.00 1068 STANDARD EQUIPMENT--Square Metal Jacket with inner liner, finishing collars, nuts snd bolts. IMPORTANT: When orderinq specify whether for use with Gun (G) or Rotary (R) Type Burner. Grates and Fire Brick are not furnished. Special fire doors and burner doors are supplied. For Gun Type Burners, furnaces will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, furnaces will be equipped with cast iron hearth rings snd brackets, hearth plate, fire box liners and mineral wool insulation. NOTE: Sufficient apace it not available on the standard hood for the total rating to be used by t number f Pip take-offs. For each a condition 12* pipe take-offs with "Y" connections may be used. NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models Flat top or one pipe type hoods furnished when ordered, without extra charge. The Arlington "Square" is furnished only with tralpht side flat top hood which is a part of the jacket. tt SEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO 8TU CAPACITIES AT REGISTERS." SEE PAGE 17 FOR ARCOFLAME OIL BURNERS AND CONTROLS; PAGE 1ft FOR CORRECT SIZE ARCOFLAME OIL BURNERS TO BE USED WITH THESE UNITS; PAGE 20 FOR HUMIDIFYING SE-4 6 03661 Sunbeam Furnaces AuEBICAN-e$>tafidai*d heating equipment Stoker Fired Furnace Number SUNBEAM STOKER FIRED FURNACES ARLINGTON Steel Pipe Furnace Catalogue Page S7-10 GALVANIZED ROUND CASING Diam. Shell tt Btu Rating Capacity Square at 1nches Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Shipping Weight 10-520-SA tD-522-SA D-524-SA D-527-SA 20* 22* 24* 27* 596 81,000 8 98.00 752 812.00 622 84,600 115.20 790 13.80 696 94,600 136.40 855 15.60 741 100,800 168.30 939 17.70 70 8110.00 822 75 129.00 865 77 152.00 932 81 186.00 1020 STANDARD EQUIPMENT--Finishing collars, vapor pan, poksr, nuts snd bolts. CLIFTON Steel Pipe Furnace Catalogue Page SI 3-15,17 GALVANIZED ROUND CASING Furnace Number tt Diam. Rating Shell Square Inches Btu Capacity at Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Shipping Weight D-8030-SA 30' C-8034-SA 34* 943 1024 128,200 $225 .*0 3205 139,300 300.50 T355 871.50 24.50 101 8247.00 1306 113 325.00 1408 STANDARD EQUIPMENT--Finishing collars, vapor pan, poker, nuts and bolts. Smoke Tees for Clifton Steel Furnaces: -------------------------------------------------------------1--0-*------8--4--.-0--0---T--r-a-d--e---P---r-ic--e-------------------------------------------------------------- ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page S11-12 ____________SQUARE METAL JACKET___________ Furnace Number Diam. Shell tt Rating Square Inches Btu Capacity at Registers Furnace with Square Jacket and Flat Hood Trade Prices Approximate Shipping Weight tD-520-SQS tO-522-SOS D-524-SQS D-527-SQS 20' 596 81,000 8120.00 1015 22* 622 84,600 142.00 1062 24* 696 94,600 162.00 1145 27* 741 100,800 197.00 1255 STANDARD EQUIPMENT--Square Metal Jacket with inner liner, finishing collars, poker, nuts and bolts. Furnace is equipped with three steel chutes for firing from rear or left or right hand side, fire brick lining and supports. Metal plates and gaskets are provided to seal chutes not used. When stoker is to be installed in front or below base of furnace, the above models cannot be used and hand fired models as shown on page 5 should be ordered less grate assembly and ash pit door. fNOTE: These sizes equipped with steel chutes on right and left tide only. NOTE: Sufficient space is not available on the standard hood for the total rating to be used by a number of small pipe take-offs. For such a condition 12* pipe take-offs with "Y" connections may be used. NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered, without bxtra charge. The Arlington "Square" is furnished only with straight side flat top hood which is a part of the jacket ttSEE PAGE 3--`'CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS." -. SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT. 7 SE-4 1 1 i1 i ! ; ; } i; iJ ; !: If Gas Fired HEATING EQUIPMENT Sunbeam Furnaces Furnace Number SGA-65 SGA-80 SG-105 SG-120 SG-140 SUNBEAM GAS FIRED FURNACES SHAWNEE -- Steel Heating Element Catalogue Page S18-T9, 29 For Use with Manufactured, Natural or Mixed Gas; L. P. Gas and Butane-Air Gas (525 Btu 1.16 Sp. Gr.) A.G.A. Rating Btu Input per Hour 65,000 60,000 105,000 120,000 140,000 Btu Capacity at Registers 36,560 45,000 59,060 67,500 76,750 ttRating Square Inches 268 331 435 496 579 Trade Prices with Standard Equipment Control Com bination GF-1, GF-2 or GF-4 $109.50 118.00 129.00 137.00 162.50 Approx. Shipping Weight 270 303 361 407 477 FACTORY ASSEMBLED. Standard Equipment Includes: Metal Jacket. Series No. 500 Baso Automatic Steel Heating Element. Pilot Valve. Pilot Filter and Gas Pressure Regulator (Except for L. P. Gas). Ribbon Burners. Manual Shut-off Valve. Draft Hood. Control Combination as specified. Control Combination GF-1 For Use vrith Manufactured, Natural or Mixed Gas. Detroit No. 411-CH Plain Thermostat. Detroit No. V-570-M Automatic Gas Valve and Transformer. Control Combination GF-2 For Use with Manufactured, Natural or Mixed Gas. MH No. T-81-A Plain Thermostat. MH Solenoid Gas Valve and Transformer? V-635-0 except for SG-120 and SG-140 for Mfd. Gas. . V-S4-C for SG-120 and SG-UO.for Mfd. Gas. Control Combination GF-4 For Use with L. P. Gas or Butane-Air Qas (525 Btu 1.16 Sp. Gr.) (Arranged for 100% Safety Shut-off) Detroit No. 411-CH Plain Thermostat. Detroit Automatic Gas Valve and Transformer: No. V-570-M for Butane-Air (525 Btu 1.16 Sp. Gr.) No. V-571-M for L. P. Gas. CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT. OPTIONAL EQUIPMENT Add to Above Trade Prices No. LA-119-A Limit Switch (Airstat) for MH Controls (Catalogue Page S2B)... $ 7.43 No. CA-805 Air Limit Control for DL Controls........................................................ 7.35 ttSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS." SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions tor Ordering Orders must specify (1) Control Combination desired. (2) Type of Gas. (If L. P. Gas, whether Butane or Propane). (3) Heat Value of Qas--Btu (at 60F. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gas. (6) Elevation at point of Installation if in excess of 2000 feet. RATINGS INDICATED ABOVE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2000 FEET. FOR RATINGS FROM 2000 FEET TO 5200 FEET AND ABOVE, REFER TO CURRENT LITERATURE. SE-4 (J. 9 03663 Sunbeam Floor Furnaces AMEBiCAN-<tada*d HEATING EQUIPMENT Gas Fired SUNBEAM GAS FIRED FLOOR FURNACES SAGINAW --Steel Heating Element . Catalogue Page S20-21, 30 Fur nace No. O-20 0-35 A.G.A. Rating For Use with Mfd., Nat. or Mixed Gas For Use with L. P. Gas Btu Input per Hour Btu Output per Hour Btu Input per Hour Btu Output per Hour 20,000 14,000 20,000 14,000 35,000 24,500 35,000 24,500 For Use with Butane-Air Gas 525 Btu, 1.16 Sp. Gr. Btu Input per Hour Btu Output . per Hour 20,000 14,000 Trade Prices with Standard Equipment With Control Combi nation A (33.00 .41.45 With Con trol Combi nation B (38.00 46.45 With Con trol Combi nation C With Con trol Combi nation E (50.60* (56.50 59.05* 64.95 App. Ship ping Wgt. 110 135 Welded Steel Heating Element. Outer and Inner Casing. Floor Register. Control Combination as specified. Standard Equipment Includes: Burner, Piping, Lighting Rod.' Gas Pressure Regulator (Except for L. P. Gas.) Draft Hood. Control Combination A -- Manual Control with Locking Dovloo Control Combination B--Manual Control with Baso Automatic Pilot For Use with Mfd., Nat, or Mixed Gas. For Use with Mfd., Nat., Mixed or L. P. Gas. Main and Pilot Gas Cocks. Pilot Burner. No. 831-1 Baso Thermostatic Main and Pilot Valve--(100% "Shut-ofT). Pilot Burner. Control Combination C -- Gonoral Controls Solf-Energlzlng Sot *For Use with Mixed Gas (800 Btu Minimum Con tent) or Natural Gaa only. Control Combination E--Mlnneapolls-Honeywcll Y-77-C Low Voltage Sot For Use with Mfd., Nat, Mixed, or L P. Gas. Main and Pilot Gas Cocks. T-80-1 Thermostat. B-60-6 Automatic Gas Valve. PG-6 Pilot Generator. 30 Ft. Two-wire Cable. No. 831-1 Baso Automatic Main and Pilot Valve--(100% ''Shut-off'*). Pilot Burner. No. T-81-A Plain Thermostat. No V-835-0 Solenoid Gas Valve and Transformer. 30 Ft Two-wire Cable. IMPORTANT NOTE: Specify ONLY Control Combination B or E for Use with Liquefied Petroleum Gas or Butane-Air Gas, 525 Btu, 1.16 Sp. Gr. Deduct (3.35 from Trade Prices shown above for omission of Gas Pressure Regulator when specified for L. P. Gas. CONTROL COMBINATION BY LETTER DESIGNATION MUST BE SPECIFIED WITH EACH UNIT Instructions for Ordering Orders must specify (1) Control Combination Deaired. (2) Type of Gas. (If L. P. Gas, whether Butane or Propane.) (3) Heat Value of Gas--Btu (at 60F. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gaa. (6) Elevation at point of Installation if in excess of 2,000 feet. ' RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2,000 FEET. FOR ELEVATIONS ABOVE 2,000 FEET, RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL. 9 SE-4 1 i f I j i i 03664 Hand Fired AMSICAN-($tai!davd Sunbeam Winter Air hiatihg equipmiit Conditioners SUNBEAM WINTER AIR CONDITIONERS HAND FIRED Unit Number D-5520 D-5522 D-5524 D-5527 ALLERTON -- Steel Heating Element Catalogue Page S34-37 Btu Capacity at Registers 86.100 107,300 120,000 127,900 Trade Prices with Standard Equipment $186.00 208.00 238.00 278.00 Approximate Shipping Weight 1205 1256 1370 1538 Unit Number D-3080 C-3480-B CLIFFDALE -- Steel Heating Element Catalogue Page S38-40 Btu Capacity at Registers Trade Prices Including Smoke Tee end Standard Equipment 162,500 177,000 $376.00 457.00 Approximate Shipping Weight 2219 2432 Squire Mete) Jacket Inner Casino and Rings. Standard Equipment Includes; Blower Cabinet. Blower, Belt and Pulleys. Rubber Mounted Motor with overload protection. Air Filters. NOTE: OL No. CA-610 or MH No. LA-412-A Blower Switch--single pole can be furnished if desired, and if specified on order, at additional Trade Price of $8.40. Q> NOTE: Blower cabinets on Allerton and Cfiffdaie Units can be attached to either right or left side of heating jacket. SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR TEMPERATURE CONTROL EQUIPMENT. SE-4 10 W 03665 Sunbeam Winter Air AMEBiQUt-ij'tflmIflwl Conditioners ^ mmc eqtomeot OH Fired Stoker Fired SUNBEAM WINTER AIR CONDITIONERS OIL FIRED ALLERTON -- Steel Heating Element Catalogue Page S34-36 For use with Gun or Rotary Type Burnera Unit Number D-5522-G or R D-5524-G or R D-5527-G or R Btu Capacity at Registers 107,300 120,000 127,900 Trade Prices with Standard Equipment (208.00 238.00 278.00 Approximate Shipping Weight 1027 1139 1250 CLIFFDALE --Steel Heating Element Catalogue Page S38, 40 For use with Gun or Rotary Type Burners Unit Number Btu Capacity at Registers Trade Prices Including Smoke Tee and Standard Equipment Approximate Shaping Weight O-30SO-G or R C-3480-GB or RB 162,500 . 177,000 (376.00 457.00 1775 1919 IMPORTANT: When ordering specify whether for use with Gun (Gj or Rotary (R) Type Burner. For Gun Type 8urner, Units will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, Units will be equipped with cast iron hearth rings and brackets, hearth plate, fire box liners and mineral wool insulation. Grates and Fire Brick are not furnished. Special fire doors and burner doors are supplied. SEE PAGE 17 FOR ARCOFLAME OIL BURNERS AND CONTROLS; PAGE 18 FOR CORRECT SIZE ARCOFLAME OIL BURNERS TO BE USED WITH THESE UNITS. ________ STOKER FIRED ALLERTON-- Steel Heating Element _______ Catalogue Page S34-36_______ Unit Number D-5522-SA D-5524-SA 0-5527-SA Btu Capacity at Registers 107,300 120,000 127,900 Trade Prices with Standard Equipment (208.00 238.00 278.00 Approximate Shipping Weight 1184 1284 1407 CLIFFDALE -- Steel Heating Element _______ Catalogue Page S38, 40_______ Unit Number Btu Capacity at Registers Trado Prices including Smoke Tee and Standard Equipment Approximate Shipping Weight D-3080-S C-3480-S8 162,500 177,000 (376.00 457.00 2033 2215 Unit is equipped with three steel chutes for firing from rear or left or right hand side, firs brick lining and supports. Metal plates and gaskets are provided to seal chutes not used. when stoker is to be installed in front or below base of unit, the above models cannot be used and hand fired unite as shown on page 10 should be ordered less grate assembly, ashpit door, and hand firing accessories. *NOTE: These units equipped with steel chutes on right and left side only. Square Metal Jacket. Inner Casing and Rings. OIL FIRED OR STOKER FIRED Standard Equipment Includes: Blower Cabinet. Blower, Belt, and Pulleys. Rubber mounted motor with overload protection. Air Filters. NOTE: Blower cabineta on Allerton and Cliffdate Models can be attached to either right or left side of heating jacket. SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT. 11 SE-4 (' i I 03666 Oil Fired J\illERICAltfSunbeam Winter Air heatihg equipment Conditioners SUNBEAM WINTER AIR CONDITIONERS OIL FIRED WINTERGLO ARCOFLAME OIL HEATING UNITS FACTORY ASSEMBLED AND PRE-WIRED Steel Heating Element with Blower under Heating Compartment Unit Number Burner Model Number Oil Firing Rate Gals, per Hr. Btu Capacity at Bonnet Trade Prices with Standard Equipment Approx. Shipping Weight 1203-OB 1205-OB MF-S MF-S .85* 1.00 85,000 . 105,000 $297.50 312.00 561 572 1.00 Gallon Nozzle furnished. *Pump Factory set at 80 lbs. pressure. The Wlnterglo Unit has Heating Element and Blower Unit enclosed in a single jacket. Standard Equipment Includes: Square Metal Jacket. Air Filter. Inner Lining. Draft Stabilizer. Blower, Belt and Pulleys. High Temperature Steel Heat Lib-O-Rator Rubber Mounted Motor with Combustion Chamber. Overload Protection. . Master Control Switch. Model MF-S Special Flange Type Arcoflame Oil Burner and Nozzle, CA-701 Stack Control; 41t-CH Ther mostat. CA-816 Blower and Limit Control. NOTE: Detroit 411-CDN Day-Night Heat Compensated Thermostat and 772 Tern-Clock Combination may be substituted for 411-CH Thermostat -- if desired, so specify on order and add $17.63 to the above Trade Prices. - .The WINTERGLO Unit, with Its special flange type Arcoflame 0(1 Burner, is listed fer closet or alcove Installation by Underwriters' Laboratories, Is approved for Installation with loss than standard clearance And may be Installed en combustible flooring. WINTERGLO WINTER AIR CONDITIONER FACTORY ASSEMBLED AND PRE-WIRED Steel Heating Element with Blower under Heating Compartment Unit Number 1203-0 1205-0 Oil Firing Rate Gals, per Hr. .85 1.00 Btu Capacity at Bonnet 85,000 105,000 Trade Prices with Standard Equipment $177.90 192.40 Approx. Shipping Weight 472 483 Squlrft Mtll Jiek.L inner Lining. Blower, Belt and Pulleys. Rubber Mounted Motor with Overload Protection. Standard Equipment Includes: Air Filter. High Temperature Steel Heat Lib-O-Rator combustion Chamber. Master Control Switch. NOTE: Detroit CA-816 Blower and Limit Switch (Short Shank) can be furnished if desired, and if speci fied on order, at additional Trade Price of $14.46. When furnished lees Arceflame Oil Burner, It Is recommended that unit be fired at th# specified firing rate, end with an ell burner which complin with Commercial Standards CS-76. I NOTE: WINTERGLO Units are regularly furnished with niter frame which may be located on either side. If desired, and ao specified on order, special air filter base for bottom return air inlet will be substituted at no additional charge. _ SEE PAGE 20 FOR HUMIOIFYING EQUIPMENT. SE-4 12 03667 Sunbeam Winter Air Conditioners AMEHiCAN-c^taudatfd HEATING EQUIPMENT Oil Fired SUNBEAM WINTER AIR CONDITIONERS OIL FIRED SARATOGA and WESTMORELAND ARCOFLAME OIL HEATING UNITS Steal Heating Element Catalogue Page S41-46 Unit Number Burner Model Number Nozzle Size Gallons per Hour Btu Capacity at Registers Trade Prices with Standard Equipment Approximate Shipping Weight E-11WJ-F B-1124-6A B-1127-BA B-I134-BC-18-M B-1134-8C-18-K B-M34-BC-21-K M-S C-1S CMS C-1S X L-1S . L-1S 1.25* 1.50 2.00 2.50 3.00 3.50 95,000 150,000 200,000 240,000 285,000 330,000 $317.60 409.70 499.20 545.20 572.20 618.20 1130 1552 1833 2174 2265 2401 Set pump 80-90 lbs. pressure. The Saratoga, No. E-1120-F, has Heating Element and Blower enclosed in single Jacket. The Westmore land Units have Heating Element enclosed in a separate Jacket and Blower enclosed in a cabinet which can be attached to either right or left side of Heating Jacket Standard Equipment Includes: Square Metal Jacket' Inner Lining. Blower, Belt, and Pulley*. Rubber Mounted Motor with Overload Protection. . ... Air Filter*. Draft Stabilizer. Heat Lib-O-Rator Molded Refractory Combustion Chamber. ARCOFLAME Oil Burner and Noz2te; CA-701 Stack Control; No. 20 Control Set (411-CH Thermostat. CA-615 Blower and Limit Control). NOTE; Detroit 411-CDN Day-Night Heat Compensated Thermostat and 772 Tom-Clock Combination may be substituted for 411-CH Thermostat in No. 20 Control Set; the suffix "A" after Control Set Number will designate this substitution. If desired, add $17.63 to the above Trade Prices. SARATOGA and WESTMORELAND -- Steel Heating Element Catalogue Page S4M5 Without Oil Burner or Controls Unit Number E-1120-F B-1124-BA B-1127-8A B-I134-BC-1S-H B-1134-BC-IS-W B-1134-BC-21-K Recommended Nozzle Size Gallons per Hour 1.25 1.50 2.00 2.50 3.00 3.50 Btu Capacity at Registers 95,000 150,000 200,000 240,000 285,000 330,000 Trade Prices with Standard Equipment $186.00 264.00 352.00 398.00 410.00 456.00 Approximate Shipping Weight 876 1263 1521 1861 1679 2014 Standard Equipment Includes: Squira Matal JackaL Inner Lining. Blower, Belt, and Pulley*. Rubber Mounted Motor with Overload Protection. Air Filters. Mineral Wool Insulation. Refractory Brick. SEE PAGE 17 FOR ARCOFLAME BURNERS AND CONTROLS; PAGE 18 FOR HEAT LIB-O-RATOR COMBUSTION CHAMBERS; PAGE 20 FOR HUMIDIFYING EQUIPMENT. 13 SE-4 03668 f Gas Fired heating equipment Sunbeam Winter Air Conditioners o SUNBEAM WINTER AIR CONDITIONERS SENECA -- GAS FIRED -- Catalogue Page S47-48, 60 Steel Heating Element -- With Blower at Right of Heating Compartment Unit Number SL-65 SL-105 SL-125 SL-150 For Use with Manufactured, Natural or Mixed Gat; L. P. Gas and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) A.G.A. Rating Btu Input per Hour 65,000 105,000 125,000 150.000 Btu Capacity at Registers 57,600 71,400 85,000 102,000 Trade Prices with Standard Equipment Control Combinations AC-1, AC-2 or AC-4 6166.00 196.00 225.00 246.00 Approx. Shipping Weight 414 463 505 590 WYANDOTTE -- GAS FIRED -- Catalogue Page $49-50, 60 -- FACTORY ASSEMBLED Steel Heating Element -- With Blower Under Heating Compartment Unit Number For Use with Manufactured, Natural or Mixed Gas; L. P. Gas and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) A.G.A. Rating Btu Input per Hour Btu Capacity at Bonnet Trade Prices with Standard Equipment Control Combinations AC-1, AC-2 or AC-4 Approx. Shipping Weight SUA-55 SUA-70 SUA-85 SUA-105 55,000 70,000 85,000 105,000 44,000 56,000 66,000 64,000 8174.00 182.00 192.00 203.00 295 393 423 500 Standard Equipment Includes: Metal Jacket. Steel Heating Element. Pilot Filter and Gas Pressure Regulator (except for L. P. Gas). Manual Shut-off Valve. Series No. 500 Baso Automatic Pilot Valve. Control Combination as Specified. Air Filters. Ribbon Burners. Draft Hood. Blower-Motor Unit. Control Combination AC-1 Control Combination AC-2 Control Combination AC-4 For Use with Manufactured, Natural or Mixed Gas For Use with Manufactured, Natural or Mixed Gas For Use with L. P. Gas or ButaneAir Gas (525 Btu, 1.16 Sp. Gr.) (Arranged for 100% Safety Shut-off) Detroit No. 411-CH Plain MH No. T-61-A Plain Thermostat. Detroit No. 411-CH Plain f Thermostat. MH Solenoid Gas Valve with Detroit No. V-570 Automatic Gas Transformer: Thermostat. Detroit Automatic Gas Valve and Valve with Transformer. V-835-A except for SL-125 and Transformer: Detroit No. CA-615 Blower and SL-150 for Mfd. Gas. No. V-570 for Butane-Air Gas Limit Switch. V-84-A with SL-125 and SL-150 (525 Btu, 1.16 Sp. Or.) for Mfd. Gas. No. V-571 for L. P. Gas. MH No. LA-101-A Blower and Detroit No. CA-815 Blower and Limit Switch. Limit Switch. CONTROL COMBINATION BY NUM8ER MUST BE SPECIFIED WITH EACH UNIT. WYANDOTTE Units are regularly furnished with filter frame which may be located on either side. If desired, and to specified on order, special Air Filter Base for bottom return air inlet will be substituted at no additional charge. SEE PAGE 20 FOR COMBINATION "S" FLOAT HUMIDIFIER; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions for Ordering Orders must specify (1) Control Combination desired. (2) Type of Gas. (If L. P. Gas, whether Butane or Propane.) <3) Heat Value of Gae--Btu (at GOT. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gas. (6) Elevation at point of Installation if in excess of 2,000 feet. RATINGS INDICATED ABOVE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2.000 FEET. FOR RATINGS FROM 2,000 FEET TO 5,200 FEET AND ABOVE, REFER TO CUR RENT LITERATURE. SE-4 14 03669 Sunbeam Winter Air American-g^taitdard Conditioners heating equipment SUNBEAM WINTER AIR CONDITIONERS MOHAWK -- GAS FIRED Catalogue Page S51-54, 60 Cast Iron Heating Element Unit Number tK-60 K-80 K-100 K-120 K-150 K-180 K-200 K-240 ttK-300 For Use with Manufactured, Natural or Mixed Gas; L. P. Gaa and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) A.G.A. Rating Btu Input per Hour 60,000 80,000 100,000 120,000 150.000 180,000 200,000 240,000 300,000 Btu Capacity at Registers 40,800 54,400 68,000 81,600 102,000 122,400 136,000 163,200 204,000 Trade Prices with Standard Equipment Control Combinations AC-2, AC-3* or AC-4 6212.00 235.00 260.00 290.00 330.00 375.00 405.00 457.00 542.00 Approx. Shipping Weight 527 765 847 905 1239 1246 1557 1605 1883 Standard Equipment Includes: Metal Jacket. Manual Shut-off Valve. Cast Iron Heating Sections. Air Filters. Pilot Pifter antf Gas Pressure Regulator (except for L. P. Gas). Ribbon 8urnert. Blower-Motor Unit. Draft Hood. Series No. 322 Baso Automatic Pilot Valve for each section for Manufactured, Natural and Mixed Gas--(Control Combinations AC-2 and AC-3). Series No. 500 Baso Automatic Pilot Valve (arranged for 100% Safety Shut-off for L. P. Gas and 8utane-Air Gas, 525 8iu, 1.16 Sp. Or.)--(Control Combination AC-4). Control Combination as specified. Control Combination AC-2 Control Combination AC-3 Control Combination AC-4 For Use with Manufactured, Natural or Mixed Gee For Use with Manufactured, Natural or Mixed Gas For Use with L. P. Gas or ButaneAir Gas (525 Btu, 1.16 Sp. Gr.) (Arranged for 100% Safety Shut-off) MH No. T-81-A Plain Thermostat. MH Solenoid Qas Valve and Transformer: V-835-A on K-60 through K- 100 for Mfd. Gas; on K-60 through K-150 for Nat. and Mixed Gas. V-84-A for remainder of Mo hawk units. MH No. LA-101-A Blower end Limit Switch. Detroit No. 411-CH Plain Thermostat. Detroit No. V-574 Step Acting Automatic Gas Valve with Me chanical Limit Control and Transformer, Manuel Opening Feature, Automatic Recycling. hodDetroit No. CA-810 Blower Switch. Note: K-60 furnis with No. V570 Automatic Gas Valve end No. CA-815 Blower end Limit Switch. Detroit No. 411-CH Plain Thermostat Detroit No. V-574 Step Acting Automatic Qas Valve with Me chanical Limit Control and Transformer. Manual Opening Fea ture, Automatic Recycling. (Special for L. P. Gas.) Detroit No. CA-810 Blower Switch. Not available with K-60. tK-60 Unit not evailsble for use with Butane-Air Gas. For L. P. Gas, K-60 Trade Price indicated above includes MH No. T-11-A Plain Thermostat, V-155-A Gas Valve, LA-101-A Blower and Limit Switch and epecial Control for 100$! Safety Shut-off, ttK-300 Unit not available for use with Butane-Air Gae. K-80, K-IOOend K-120 Units are available with Push Button Electric Ignition, on special order, with control combination AC-3 for Manufactured, Natural or Mixed Gas. When desired, specify control combination AC-3E and add $15-00 to Trade Price of Unit with AC-3 controls. CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT. SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.______________ ______________________________________________________ . Instructions for Ordering Orders must specify (1) Control Combination desired. (2) Type of Gas (If L. P. Gas, whether Butane or Propane). (3) Heat Value of Gaa.--Btu (at $0F. and 30 inches Ho). (4) Pressure available at outlet of Gas Meter. (5) Specific gravity of Gas. (6) Elevation at point of Installation If in excess of 2,000 feet. RATINGS INDICATED A80VE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2.000 FEET. FOR RATINGS FROM 2,000 FEET TO 5,200 FEET AND ABOVE, REFER TO CURRENT LITERATURE. 15 SE-4 03670 / Gas Fired heating equipment Sunbeam Winter Air Conditioners * - Unit Number KUA-60 SUNBEAM WINTER AIR CONDITIONERS CHIPPEWA --GAS FIRED --FACTORY ASSEMBLED Catalogue Page S55, GO Cast Iron Heating Element With Blower Under Heating Compartment For Use with Manufactured, Natural or Mixed Gas; L. P. Gas and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) A.G.A. Rating Btu Input per Hour 60,000 Btu Capacity at Bonnot 4S.000 Trade Prices with Standard Equipment Control Combinations A-7, A-16 or A-17 $224.00 Approx. Shipping Weight 500 Standard Equipment Includes: Metal Jacket. Cast Iron Heating Element Pilot Filter and Gas Pressure Regulator (except for L. P. Gas). Manual Shut-off Valve. Blower-Motor Unit. Air Filter*. Ribbon 8urner. Draft Hood. Series No. 500 Baso Automatic Pilot Valve (arranged for 100% Safety Shut-off for L. P. Gaa and Butane-Air Gas, 525 Btu, 1.16 Sp. Gr.)--(Control Combination A-17). Control Combination as specified. Control Combination No. A-7 Control Combination No. A-1$ For Use with Manufactured, Natural, or Mixed Gas. For Use with Manufactured, Natural, or Mixed Gas. MH No. T-81-A Plain Thermostat. MH No. V-835-A*Solenoid Gas Valve and Transformer. .... MH No. LA-101-A Blower and Limit Switch. Detroit No. 411-CH Plain Thermostat. Detroit No. V-574 Step Acting Automatic Gas Valve - with Mechanical Limit Control and Transformer, Manual Opening Feature, Automatic Recycling. Detroit No. CA-810 Blower Switch. * Control Combination No. A-17 For Use with L. P. Gas or Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) Detroit No. 411-CH Plain Thermostat. Detroit Electric Gas Valve and Transformer: No. V-571 for L. P. Gas. No. V-570 for Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) Detroit No. CA-81S Blower and Limit Switch. The Chippewa Unit is available with Push Button Electric Ignition, on special order, with control combination A-16 for Manufactured, Natural or Mixed Gas. When desired, specify control combination A-16E and add $15.00 to Trade Price of Unit with A-16 controls. CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT. The Chippewa Unit is regularly furnished with filter frame which may be located on either side. If desired, and so specified on order, special Air Filter Base for bottom return air inlet will be substituted at no additional charge. SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions for Ordering Orders must specify (l)Control Combination desired.. (2) Type of Gas, (If L. P. Gas, whether Butane or Propane.) (3) Heat Value of Gaa--Btu (at 60*F. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gaa. ' - (6) Elevation at point of Installation if in excess of 2,000 feet. RATINGS INDICATED ABOVE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2.000 FEET. FOR RATINGS FROM 2,000 FEET TO 5,200 FEET AND ABOVE, REFER TO CUR RENT LITERATURE. ., SE-4 T < 03671 Arcoflame Burners AMBICAN>(^tlttMlai*4 HEATING EQUIPMENT Arcoflame Burners ARCOFLAME OIL BURNERS COMPLETE WITH STANDARD ARCOFLAME BURNER CONTROL SET AND NOZZLEt Catalogue Page S46 (A Standard Arcoflame Burner Control Set Must Be Purchased With Each Arcoflame Burner) Model Number C-1S C-2S With Control Set Number Contents of Arcoflame Standard Control Sets 19 No. 411-CH Thermostat. For Gravity Furnaces No. CA-805 Air Limit Control. 20 For Winter Air Conditioners No. 411-CH Thermostat. No. CA-81S Combination Blower and Limit Control. Trade Prices $124.50 130.70 C-3S For Use on 116 Volt, 60-Cycle Current MAXIMUM CAPACITY 3.00 GALLONS OIL PER HOUR Approximate Shipping Weight 140 pounds L-1S . 19 For Gravity Furnaces 20 For Winter Air Conditioners No. 411-CH Thermostat. No. CA-805 Air Limit Control. No. 411-CH Thermostat -' No. CA-315 Combination Blower and Limit Control. $137.50 143.70 L-3S For Use on 116 Volt, 60-Cycle Current MAXIMUM CAPACITY 7.00 GALLONS OIL PER HOUR Approximate Shipping Weight 165 pounds IMPORTANT: When substitution of 411-CDN end 772 combination is made for 411-CH such control sets will be designated by suffix "A" after control set number. If desired, add 117.63 to above Trade Prices. IWhen ordering Arcoflame Oil Burner be sure to specify Nozzle size desired. IMPORTANT NOTICE Trade Prices for Arcoflame Burners and Standard Burner Control Sets as shown above include, in addition to the Nozzle and Controls as listed, a No. CA-701 Arcoflame Stack Control. Arcoflame Burners will be sold only when ordered in combination with one of the Arcoflame Standard Burner Control Sets, as shown above. Additional Arcoflame Controls may be purchased separately at Trade Prices shown below. When Arcoflame Burner is ordered with Nozzle Sizes of 1.25 and 1.35 Gallons per Hour, Special Turbulator Attachment is furnished at no additional charge. Arcoflame Oil Burners are approved by the National Board of Fire Underwriters and comply with Commercial Standards CS-75. IMPORTANT NOTE: Motors and Controls regularly furnished are for 115 Volt, 60 Cycle A. C. CONTROLS FOR ARCOFLAME OIL BURNERS Catalogue Page S61-62 Trade Prices -- When Ordered Separately Stock Number Description Standard Controls--115 Volt, 60 Cycle Trade Prices CA-701 411-CH 411-CDN 1411-TD *772 CA-805 CA-815 CA-610 CA-295 Detroit Heat Compensated Thermostat Low Voltage (Scale 40-90eF.)............ Detroit Day-Nipht Heat Compensated Thermostat (Scale 40*-90F.)....... ...... Detroit Air Limit Control (High Voltage) (Scale 100S-300F.) (Stop 250'F.)----Detroit Combination Blower and Limit Control (HiQh Voltage) (Scale Blower 75*-225, Limit 100-300, Stop 200 F.).............................................................. Detroit Relay Transformer..................................................................................... <27.00 8.55 : 9.45 1.35 16.73 7.35 14.48 8.78 41I-CDN Thermostat is used only in combination with 772 Tam-Clock. {Order 411-TD and 772 Tarn-Clock to convert existing 411-CH Plain Thermostat to Automatic Day-Night operation,~ 17 SE-4 I 03672 Arcoflame Oil Burners AMERlCAN-e^taitdatHl HEATING EQUIPMENT Combustion Chambers ARCOFLAME CONVERSION OIL BURNERS FOR USE WITH SUNBEAM GRAVITY FURNACES KENWOOD A-1018-CD or BD A-104O-CD or BD A-1044-CD or BD A-104S-CD or BD A-I052-CD or BO ARLINGTON ANO ARLINGTON "SQUARE" C-2S' C-3S C-3S C-3S C-3S D-520-0 or D-S20-SOQ D-522-G or D-522-SOG D-524-G or D-S24-SOQ 0-527-0 or D-527-SQQ CLIFTON C-2S C-2S C-2S C-2S D-8030-Q C-8034-O C-2S L-3S FOR USE WITH SUNBEAM WINTER AIR CONDITIONERS ALLERTON CLIFFDALE D-5520 D-5622-G D-5524-G D-5527-G C-2S C-2S C-2S C-2S D-3080-G C-3480-GB C-2S L-3S Combustion Chamber* not furnished. See Arcoflame Oil Burner Installation and Service Guide for sug gested size and shape. NOZZLES AND STRAINERS FOR CONVERSION OIL BURNERS For Model C For Model L Gals, per Hr. Spray Angle Gals, per Hr. Spray Angle FOR SARATOGA ANO WESTMORELAND UNITS Unit Number Gala, per Hr. Spray Angle 1.25 1.35 1.50 1.65 1.75 2.00 2.25 2.50 2.75 3.00 80* 80* 80* 80* 60* 60* 60* 60* 60* 60* 3.00 3.50 4.00 4.50 5.00 5.50 6.00 $.50 7.00 60* E-1120-F 1.25* 60* B-1124-BA 1.50 60* B-1127-BA 2.00 60* B-1134-BC-18-H 2.50 $0* B-1134-BC-18-K 3.00 60* B-1134-BC-21-K 3.50 60* 60* 60 80 60 80* 45 60 60 Set Pump at 80-90 lbs. pressure if 1.25 Nozzle is used. When these Nozzles are used in Model "C" Arcoflame Burners, the Special Turbulator Attachment should be used. Special Turbulator Attachment furnished at no additional charge when these nozzles ere supplied as part of one of the Standard Arcoflame Burner Control Sets shown on page 17. HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS FOR SARATOGA and WESTMORELAND UNITS Trade Prices --When Ordered Separately Stock Number Sunbeam Unit Number Max. Gale, per Hour Trade Prices 0S 1S 2S 3S SE-4 E-1I20-F B-1124-BA B-1127-BA B-1134-BC-18-M B-1134-BC-18-M B-1134-8C-21-H 18 1.50 1.75 2.25 3.75 612.00 15.00 16.50 18.50 i i l i! I. It 03673 Air Filters AAKBICAN-e$tattdaff<! HEATING EQUIPMENT Blower-Filter Units SUNBEAM BLOWER-FILTER UNITS With Cabinet and Filters Catalogue Page S22-27 Unit Number 0-1- 9 D-1-10H D-1-12 D-1-15 1-18-F8 1-21-FB Diameter of Wheel 9* 10H' 12* 15* 18* 21* Motor Horsepower 1/6 1/4 1/4 1/3 1/* 3/4 Trade Prices $ 60.00 66.00 76.00 114.00 172.00 230.00 Approx. Shipping Weight 142 146 181 241 478 633 NOTE: OL No. CA-810 or MH No. LA-412-A Blower Switch--single pole can be furnished if desired, end if specified on order, at additional Trade Price of 88.40. Filter Sizes 20* x 25* 20* x 20* 16* x 25* 16* x 20' 15* x 20* 10* x 20* AIR FILTERS FOR REPLACEMENT Catalogue Page S57 Trade Prices Each 1* Thick *0 86 .66 .80 .80 .80 .70 2* Thick 81.33 1.16 1.16 1.16 1.16 .97 NOTE: Filters as shown at left are packaged in cartons of twelve (12) of minimum quantity. 03674 Humidifying Equipment HEATING EQUIPMENT Sunbeam Humidifier Number HUMIDIFYING EQUIPMENT Description Trade Prices FOR GRAViTY FURNACES: WA Catalogue Page S28 - Automatic Drip Humidifier: Self-contained Heat Actuated Peed Valve Assembly, Metal Pan, Shut-off Valve, Water Line and Couplings. Water Pan for ARLINGTON "SQUARE" Water Pan with Cast Iron Frame that attaches to Jacket 8 9.25 8 3.50 FOR WINTER AIR CONDITIONERS: H-4* Catalogue Page 558 S-400 Catalogue Page S58 Automatic Spray Humidifier: (For use with alt Winter Air Conditioners except Seneca and Wyandotte Units) No. H-14 Friez Humidiatat No. V-837-A Solenoid Water Valve including Transformer. 2 No. 390 Water Strainers. No. 26 Water Pressure Reducing Valve. No. 50 Assembly including: Tubing and Fittings, Shut-Off Valve, 4 Spray Nozzles with individual Shut-Off Valves. Spray Pan with capacity Adjusting Plate. Nozzle Cleaning Rod, 3 Rubber Caps for Spray Nozzles not in use. Float Humidifier: Evaporating Plates. Evaporating Pan. Water Reservoir with Float and Valve. Flexible Tube and Pipe Clamp Valve. S-401: For SUA-55; K-60; KUA-60. S-402: For 0-6520, 0-5522, D-5524; 1203-08,-0; 1205-08,-0; E-1120-F; SL-85, SL-105, SL-125, SL-150; SUA-70, SUA-85, SUA-105; K-60, K-100, K-120, K-150. S-403: For D-5527; B-H24-BA; K-180, K-200, K-240. S-404: For D-3080; B-1127-BA; K-300. S-405: For C-3480-B; B-1134-BC-18-H.-18-K,-21-KExtra Evaporating Plates, Trade Price Each 8.17 Water Pan for AULERTON, CLIFFDALE, SARATOGA and WESTMORELAND Water Pan with Cast Iron Frame that attaches to Jacket. 845.00 811.65 11.65 12.75 13.75 15.00 8 3.50 : SE-4 20 03675 r(0 Sunbeam AMERICAN-<$tattdawl heating equipment Temperature Control Equipment Combination Description Trade Prices FOR ALL HAND FIRED GRAVITY FURNACES: M-x Catalogue PageS29 A-li Catalogue Page S28 Mechanically Controlled MH Metaphram Draft Control. A self-contained mechanical draft and check regulating instrument. Thermostatically Controlled MH No. T-81-A Plein Thermoetet. MH No. LA-119-A Limit Switch (Alretet). MH No. M-S7-A Otmper Motor with Transformer. No. 933 Accessories (Cheln, S-Hooks end Pulleys). * a.4o *33.15 FOR ALL HAND FIRED WINTER AIR CONDITIONERS: Mechanically Controlled M-x MH Metaphram Draft Control. Catalogue PageS59 A self-contained mechanical draft and check regulating instrument. Catalogue PageS59 No. CA-810 DL Blower Switch. No. LA-412-A MH Blower Switch (Furnacestat). When Room Thermostat Draft Controls are not used, a blower switch is necessary for starting and stopping blower when bonnet temperature rises or fails. When controls as listed in Combination 8-1X below are used, blower switch is included in control equipment. B-lx Catalogue PsgeS59 Thermostatically Controlled MH No. T-81-A Plain Thermostat MH No. LA-101-A Blower and Limit Switch (Furnacestat). MH No. M-87-A Damper Motor with Transformer. No. 933 Accessories (Chain, S-Hooks and Pulleys). B-6x Same as above except with substitution of MH No. T-847-AChronothenr for No. T-81-A Plain Thermostat * 8.40 8 8 40 8 40 *40.20 *57.83 OPTIONAL THERMOSTATS OPTIONAL THERMOSTAT--Description Extra* Trade Prices For Use only with Unit Control Combi nation No. Replaces i 411 -CON Day-Night Heat Compensated Thermostat AND 772 Tern-Clock *17.63 SHAWNEE SENECA and \ WYANDOTTE/ MOHAWK CHIPPEWA GF-1 or GF-4 AC-1 or AC-4 AC-3 or AC-4 A-16 or A-17 411-CH Plain Thermostat T-801-A Tim-0-SUt T-847-A Night and Day Electric Clock Thermostat (Chronotherm) * 5.93 *17.63 ) SAGINAW SHAWNEE SENECA and l WYANDOTTE/ MOHAWK (CHIPPEWA E GF-2 AC-2 AC-2 A-7 These Extra* to be added to Tnds Prices of Units. Do not epply if ordered sapariiely- T-81-A Plain Thermostaf to AUTOMATIC NIGHT TURN DOWN ASSEMBLY No. Description 411-TD Night Turn Down assembly AND 772 Tern-Clock Used to convert existing 411-CH Plain Thermostat to automatic Day-Night operation Trade Price *18.08 For Use only with Unit Control Combi nation No. SHAWNEE SENECA end 1 WYANDOTTE/ MOHAWK CHIPPEWA GF-1 or GF-4 AC-1 or AC-4 AC-3 or AC-4 A-1 $ or A-17 - 21 ` SE-4 | / / 03676 S :=i.-.w;M'sr.i Water Heaters AMEBICAN-e^tattdaifd heating eqdipmeht Gas Fired Automatic Storage GAS FIRED AUTOMATIC STORAGE WATER HEATERS Heater No. 204-S . 304-S 404-S GALVANIZED STEEL Temperature and Pressure Relief Valve, $4.00 Trade Price Extra AMERICAN BUDGET {For Um with.Manufactured, Natural or Mixed Gas) Capacity Gallons Btu Input Recov. Gals, per Hour 60 Rise WITH ANODE Trade Prices Approx. Shipping Weight LESS ANODE Trade * Prices Approx. Shipping WeiQht 20 20,000 28.0 646.90 171 643.40 166 30 26,000 36.4 57.75 214 54.25 209 40 30,000 42.0 78.50 245 75.00 240 - Heater No. 204-S 304-S 404-S Capacity Gallons 20 30 40 (For Usa with Liquefied Petroleum Gas) Btu Input Recov. Gals, per Hour ` . 60 Rise WITH ANODE Trade Prices Approx. Shipping Weight 19,000 26,000 30,000 26.6 36.4 42.0 650.40 57.75 82.00 171 214 245 LESS ANODE Trade Prices Approx. Shipping Weight 646.90 54.25 78.50 166 209 240 Models for Liquefied Petroleum Gss are furnished with special thermostat and safety pilot to provide for 100% shut-off of gas to both the main burner and the pilot burner in the event of pilot failure. Heater No. (For Use with Butane-Air Gaa: 52$ Btu, 1.16 Sp. Gr.) Capacity Gallons Btu Input Recov. Gala, per Hour 60 Rise WITH ANODE Trade Prices Approx. Shipping Weight LESS ANODE Trade Prices Approx. Shipping Weight" 204-S 304-S 404-S 20 19,000 26.6 650.40 30 26,000 36.4 57.75 40 21,000 29.4 82.00 171 646.90 214 54.25 245 78.50 166 209 240 Gas Inlet I.P.S. Center Flue-Connection 3* Size of Water Connection HIGH ALTITUDE (2000-5200 feet) RATING FOR NO. 304-S FOR USE WITH MANUFACTURED, NATURAL, MIXED AND LIQUEFIED PETROLEUM GASES, INCLUDING BUTANE-AIR (525 Btu, 1.16 Sp. Gr.)-24,000 Btu INPUT; RECOVERY GALLONS PER HOUR. 60 RISE-33.6. RATINGS SHOWN FOR NO. 204-S ANO NO. 404-S ARE FOR SEA LEVEL. RATINGS SHOULD BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1.000 FEET ABOVE SEA LEVEL. SE-4 22 03677 / o V 03678