Document 69qOzm4eKb1apGNqoJ42dXVE
bO
SUNBEAM
GRAVITY FURNACES WINTER AIR CONDITIONERS
Price Book SE-4
SEPTEMBER 26, 1949
NOTICE The Trade Prices shoicn herein do not include
freight or cartage
Page .
GENERAL TERMS..................................................
2
FURNACE SELECTION INFORMATION.............. 3
SUNBEAM GRAVITY FURNACES........................ 4-8
i SUNBEAM FLOOR FURNACES............................. 9 SUNBEAM WINTER AIR CONDITIONERS.......... 10-16
ARCOFLAME OIL BURNERS,;............................... 17-18
SUNBEAM BLOWER-FILTER UNITS.................... 19
AIR FILTERS............................................................. 19
,, HUMIDIFYING EQUIPMENT.................................. 20
TEMPERATURE CONTROL EQUIPMENT...... .
21
'J GAS WATER HEATERS...................... 22'
American c^taudand Radiator ^^aiiitai^
CORPORATION
Pittsburgh 30, Pm,
03655
General Terms
AMERiCAN-c^tacdatfd
heajuig iquipmekt
General Terms
' Illustrations and descriptions of Plate Numbers listed in the price book will be found in the Warm Air Heating Equipment Section of the "AMERICAN-STANDARD" GENERAL CATALOGUE. Items illustrated in the GENERAL CATALOGUE and not included in this price book are discontinued. Items added since the issuance of the last Catalogue
Revision are described for identification! ' .
PRICES
All prices herein quoted supersede all prior quotations and are subject to change with
out notice.
:.
No obligation is assumed by this Corporation to sell to any one holding this book any of the items listed herein at the prices stated, i. .
A minimum invoice charge of forty-five cents (.45) will apply on any item including re pair parts.
TAXES
To the prices and terms quoted add any Manufacturers' or Sales Tax payable on the
transaction under any effective statute. .. .
,.
TRANSPORTATION CLAIMS
The responsibility of this Corporation ceases upon delivery of goods in good order to transportation companies, and all goods are shipped at consignees' risk.
_ ORDERS
The Corporation shall not be liable for any delay or failure in the delivery or shipment
of products or for any damages suffered by reason of such delay or failure, when such
delay or failure is, directly or indirectly, due to fire, flood, accidents, riots, war, embargo,
labor stoppages, inadequate transportation facilities, shortage of material or supplies,
regulation by Governmental authority, or any cause or causes beyond this Corporation's
control. -
-
GUARANTEE
We guarantee goods manufactured by this Corporation to the extent that we shall fur
nish by freight new articles or parts for any articles or parts of such goods found defective
in workmanship or material within one year after installation. -
-
In all claims, no labor or other consequential damages shall be allowed.
Goods of other manufacturers sold by us are not guaranteed by this Corporation.
CLAIMS
No claims under the above guarantee, or for variances from or shortages in orders will be allowed, unless presented within sixty (60) days after receipt of goods. _
SPECIAL PRODUCTS
Items of special nature or products requiring special manufacture or supervision are not subject to change or cancellation after production is started.
RETURNED GOODS
Good material of standard manufacture must not be returned for crec it without first
securing written permission, and when so returned will be subject to a deduction of 10%
for re-handling, and all transportation charges, including freight and cartage, will be
paid by shipper.
*
. Materials made on special order are not subject to return.
SHIPPING WEIGHTS Weights are for customers' convenience only, are approximate and not guaranteed.
SE-4
2
Freight Conditions applying to
Price Book SE-4
AMERiCAN-c$tandard
SUNBEAM WARM AIR HEAT1NQ EQUIPMENT
September 26,1949
FREIGHT ALLOWANCES
All previous freight allowances are void.
SHIPMENTS OF AMEWCAN-^andard WARM AIR HEATING EQUIPMENT INCLUDING SUNBEAM GRAVITY FURNACES, WINTER AIR CONDITIONERS, FLOOR FURNACES, BLOWER-FILTER UNITS, ARCOFLAME OIL BURNERS AND CONTROLS, AND (HUMIDIFIERS, CONTROLS AND ACCESSORIES WHEN SHIPPED WITH COMPLETE UNITS) ARE: F.o.b. Factory with the rail carload rata of freight allowed as maximum on shipments of 200 pounds or more; this allowance not to exceed the lowest volume rate. No freight allowance will be made on shipments of less than 200 pounds. In no case is this allowance to be in excess of the actual freight paid. No freight allowance will be made on shipments of Repair Parts or on shipments of Humidifiers, Controls and Accessories when shipped separately.
AIR FILTERS FOR REPLACEMENT Shipments of twelve (12) or more Air Filters are f.o.b. Factory with rail freight up to the amount of $2.86 per hundred pounds allowed.
WATER HEATERS Shipments of Water Heaters are f.o.b. Factory with the rail carload rate of freight allowed as maximum on shipments of 200 pounds or more; this allowance not to exceed the lowest volume rate. No freight allowance will be made on shipments of less than 200 pounds. In no case is this allowance to be in excess of the actual freight paid. No freight allowance will be made on shipments of Water Heater Repair Parts.
On orders for shipment to any point not in the 48 United States, or the District of Columbia, freight allowances will be those applicable to the port of export only. Above allowances will not include any additional charges not included in road haul rates for services performed by carrier at destination, such as detention of carrier's equipment, redeliveries, etc. Any such additional charges will be for account of the wholesale distributor. We reserve the choice of transportation facilities and shipping point. Freight allowances are subject to change without notice.
A urmr<> ^4-r+%An+*A
CORPORATION Pittsburgh 30, Pa.
03657
Furnace Selection Information
j^MEEIcjuj-^tflPdflfd
heatiboeqcipmsit
Furnace Selection Information
Converting Requirements in Square Inches to Btu Capacities at Registers
Square Inch Ratings shown for all Sunbeam Gravity Furnaces are based on approximately one-half of capacity being supplied to first floor and one-half to second floor. For conditions where entire demand is all on one floor, or is substantially greater on one floor than the other, convert the square inch requirements of the installation into Btu by the following method:
Multiply square inch requirements of first floor by 111;
Multiply square inch requirements of second floor by 167; Add the results and select Furnace having Btu capacity at
register equal to or greater than the total.
Examples:
1. Assume one story building requires 675 square inches of leader pipe:
675 x 111 = 74,925 Btu at registers
2. Assume two story building with furnace heating only second floor requires 390 square inches of leader pipe: 390 x 167 = 65,130 Btu at registers
3. Assume two story building requires 565 square inches of leader pipe on first floor, and 185 square inches on second floor: ,
565 x 111 = 62,715 Btu at registers -- first floor
185 x 167 = 30,895 Btu at registers -- second floor
93,610 Total Btu at registers
Ratings
Square Inch Ratings are calculated by dividing the Btu Capacity at Registers by 136.
Btu Capacity at Registers for all Sunbeam Gravity Furnaces is 75% of
Btu Capacity at Bonnet.
...
Btu Capacity at Registers for all Sunbeam Winter Air Conditioners is 85% of Btu Capacity at Bonnet.
3 SE-4
r
i
03658
Hand Fired
AMHUCAN-<$tAttda*d HEATING EQUIPMENT
Sunbeam Furnaces
SUNBEAM HAND FIRED FURNACES
CAST IRON Catalogue Page SI-6
KENWOOD Cast Iron Pipe Furnace
Furnace Number
Diam.
Fire Pot
Btu
ItRating Capacity
Square
at
Inches Registers
Furnace Only
Trade Prices
Approx. Shipping
Weight
Casing and Hood
Trade Prices
Approx. Shipping Weight
Furnace with Casing and Hood
Trade Prices
Approx.
Shipping Weight
A-1018-CD A-1040-CD
A-10+4-CD A-1048-CD A-1052-CD
18' 20' 22' 24'
26'
390 53,000 8 92.00 699 $ 6.00 467 63,500 99.50 835 10.50 637 73,000 111.50 965 12.50 597 81,260 125.00 1076 14.00 683 92,900 152.00 1376 . 17,00
56 $100.00 755
68
110.00
903
74 124.00 1039
60 139.00 1156
92 169.00 1468
STANDARD EQUIPMENT--Check draft, finishing collars, Vapor pan, poker, draft regulator, chain and pulleys, asbestos cement, nuts and bolts.
NOTE: Cone type hoods are regularly furnished. Flat top or one pipe type hoods furnished when ordered without extra charge.
ttSEE PAGE 3--`''CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS/'
KENWOOD Cast Iron Pipeless Furnace
Furnace Number
Diameter Fire Pot
Btu Capacity
Trade Prices Complete
Approximate Shipping Weight
A-1018-BD A-1040-BD A-1044-BD A-1048-BD A-1052-BD
18' 20' 22' 24' 26'
70,700 84,700 97,300 108,100 123,800
$124.00 144.00 167.00 189.00 216.00
916 1121 1266 1410 1737
STANDARD EQUIPMENT--Register, check draft, vapor pan, poker, draft regulator, chain and pulleys, asbestos cement, nuts and bolts, warm-air and return-air extensions.
NOTE: Duplex Crete* are regularly furnished with Kenwood Pipe and Pipeless Furnaces. Triangular Grates are available at no additional charge; when ordered, specify with suffixes "CT" or "BT,"' instead of "CD" or "BD," respectively.
ARLINGTON Steel Pipeless Furnace
Furnace Number
Diameter Shell
Btu Capacity
Trade Prices Complete
Approximate Shipping Weight
BD-520 8D-522 BD-524 BD-527
20' 22' 24' 27'
90,500 112,800 126,200 134,500
$151 .00 177.00 207.00 239.00
1102 1157 1255 1369
STANDARD EQUIPMENT--Register, check draft, vapor pan, poker, draft regulator, chain and pulleys, asbestos cement, nuts and bolts, warm-air and return-air extensions.
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR TEMPERATURE CONTROL EQUIP* MENT.
NOTE: Deduct 5% from price of Cast Iron or Steel Furnaea Only, respectively, for omission of Grate Assembly, Ashpit Door, and Hand Firing Accessories.
SE-4
4
03659
Sunbeam Furnaces
AMERlCAN-c$Uttd(awi
heatiic equipmext
Hand rired
Furnace Number
SUNBEAM HAND FIRED FURNACES
ARLINGTON Steel Pipe Furnace Catalogue Page S7-10
GALVANIZED BOUND CASING
Diam. Shell
Btu
ttRating Capscity
Square
at
Inches Registers
Furnace Only
Trade Prices
Approx. Shipping Weight
Casing and Hood
Trade Prices
Approx. Shipping Weight
Furnace with Casing end Hood
Trade Prices
Approx. Shipping Weight
0-520
20'
499
67,600 6 96.00
609 012.00
70 0110.00 879
D-522
22'
622
64,600 115.20 656 13.80
75
129.00
931
D-524
24'
696
94,600 136.40 921 15.60
77
152.00
998
0-527 27' 741 100,000 168.30 1021 17.70 81 186.00 1102
STANDARD EQUIPMENT--Check draft, finishing collars, vapor pan, poker, draft regulator, chain and pulleys, nuts and bolts.
Furnace Number
CLIFTON Steel Pipe Furnace Catalogue Page S13-15,17
GALVANIZED ROUND CASING
Diam. Shell
Btu
ttRating Capacity
Square
at
Inches Registers
Furnace Only
Casing and Hood
Furnace with Casing and Hood
Approx.
Approx.
Approx.
Trade Shipping Trade Shipping Trade Shipping
Prices Weight Prices Weight Prices Weight
D-0030
30'
943 128,200 0225.50 1375 021.50 101 0247.00 1476
C-6034
34'
1,024 139,300 300.50 ,1553 24.50 113
325.00 1666
STANDARD EQUIPMENT--Check draft, finishing collars, vapor pan, poker, drift regulator, chain and pulleys, nuts and bolts.
Smoke Teos for Clifton Steel rurneeee: 10*--44.00 Trade Price
Furnace Number
ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page S11-12
____________SQUARE METAL JACKET___________
Diameter Shell
ttRating Square Inches
Btu Capacity at Registers
Furnace With Square Jacket and Fla t Hood
Trade Prices
Approx. Shipping
Weight
0-520-SQ D-522-SQ D-524-SO 0-527-SQ
20' 22' 24' 27'
499
67,800
0120.00
622
84,600
142.00
696
94,600
162.00
741
100,800
197.00
1059 1115 1205 1317
STANDARD EQUIPMENT--Square Metal Jacket with inner liner, check draft, finishing collan, poker.
draft regulator, chain and pulleys, nuts and bolts. ---
~ ''
NOTE: Deduct 5% from price of Furneeo Only for omission of Grate Assembly, Ashpit Door, and Hand Firing Accessories.
NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered without extra charge. The Arlington "Square" Model is furnished only with straight side flat top hood which is a part of the jacket. ftSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO 8TU CAPACITIES AT. REGISTERS
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 2t FOR TEMPERATURE CONTROL EQUIPMENT,
5 SE-4
Oil Fired
AMEHICAN-C$tattdai
heating equipment
Sunbeam Furnaces
Furnace Number
SUNBEAM OIL FIRED FURNACES
ARLINGTON Steel Pipe Furnace Catalogue Page S7-10
GALVANIZED ROUND CASINO
ft Btu
Diam. #Rating Capacity
Shell Square
at
Inches Registers
Furnace Only
Trade Prices
Approx. Shipping Weight
Casing and Hood
Trade Prices
Approx. Shipping Weight
Furnace with Casing and Hood
Trade Prices
Approx. Shipping Weight
D-520-G or R D-522-G or R D-524-G or R D-527-G or R
20' 22' 24'
27'
596 61,000 6 96.00 601 912.00
622 84.600 115.20 627
13.60
696 94,600 136.40 656
15.60
741 100,600 166.30 730
17.70
70 9110.00 671 75 129.00 702 77 152.00 733 61 186.00 811
STANDARD EQUIPMENT--Finishing collars, vapor pan, nuts and bolts.
Furnace Number
CLIFTON Steel Pipe Furnace Catalogue Page SI 3-17
GALVANIZED ROUND CASING
tt Btu
Diam. Rating Capacity
Shell Square
at
Inches Registers
Furnace Only
Trade Prices
Approx. Shipping
Weight
Casing and Hood
Trade Prices
Approx. Shipping Weight
Furnace with Casing and Hood
Trade Prices
Approx. Shipping
Weight
D-6030-G or R 30' C-8034-G or R 34'
943 126,200 9225.50 1024 139,300 300.50
946 1057
921.50 24.50
101 9247.00 1049 113 325.00 1170
Smoko Toot for Clifton Stool Fumaeos: 10'--$4.00 Trade Price
STANDARD EQUIPMENT--Finishing collars, vapor pan, nuts and bolts.
Furnace Number
ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page S11-12
____________SQUARE METAL JACKET_________
Diam. Shell
tt Rating Square Inches
Btu Capacity
at Registers
Furnace with Square Jacket and FU t Hood
Trade Prices
Approx. Shipping Weight
D-520-SOG or SC)R D-522-SOQ or S< >R D-524-SQG or SC >R D-527-SQG or $() R
20' 22' 24' 27'
596
81,000
9120.00
863
622
84,600
142.00
916
696
94,600
162.00
978
741
100,600
197.00
1068
STANDARD EQUIPMENT--Square Metal Jacket with inner liner, finishing collars, nuts snd bolts.
IMPORTANT: When orderinq specify whether for use with Gun (G) or Rotary (R) Type Burner. Grates and Fire Brick are not furnished. Special fire doors and burner doors are supplied. For Gun Type Burners, furnaces will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, furnaces will be equipped with cast iron hearth rings snd brackets, hearth plate, fire box liners and mineral wool insulation. NOTE: Sufficient apace it not available on the standard hood for the total rating to be used by t number f Pip take-offs. For each a condition 12* pipe take-offs with "Y" connections may be used. NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models Flat top or one pipe type hoods furnished when ordered, without extra charge. The Arlington "Square" is furnished only with tralpht side flat top hood which is a part of the jacket. tt SEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO 8TU CAPACITIES AT REGISTERS." SEE PAGE 17 FOR ARCOFLAME OIL BURNERS AND CONTROLS; PAGE 1ft FOR CORRECT SIZE ARCOFLAME OIL BURNERS TO BE USED WITH THESE UNITS; PAGE 20 FOR HUMIDIFYING
SE-4
6
03661
Sunbeam Furnaces
AuEBICAN-e$>tafidai*d
heating equipment
Stoker Fired
Furnace Number
SUNBEAM STOKER FIRED FURNACES
ARLINGTON Steel Pipe Furnace Catalogue Page S7-10
GALVANIZED ROUND CASING
Diam. Shell
tt Btu
Rating Capacity
Square
at
1nches Registers
Furnace Only
Trade Prices
Approx. Shipping Weight
Casing and Hood
Trade Prices
Approx. Shipping Weight
Furnace with Casing and Hood
Trade Prices
Approx. Shipping Weight
10-520-SA
tD-522-SA D-524-SA D-527-SA
20* 22* 24*
27*
596 81,000 8 98.00 752 812.00
622
84,600 115.20
790
13.80
696 94,600 136.40 855 15.60
741
100,800 168.30
939
17.70
70 8110.00 822 75 129.00 865 77 152.00 932 81 186.00 1020
STANDARD EQUIPMENT--Finishing collars, vapor pan, poksr, nuts snd bolts.
CLIFTON Steel Pipe Furnace Catalogue Page SI 3-15,17
GALVANIZED ROUND CASING
Furnace Number
tt Diam. Rating Shell Square
Inches
Btu Capacity
at Registers
Furnace Only
Trade Prices
Approx. Shipping Weight
Casing and Hood
Trade Prices
Approx. Shipping Weight
Furnace with Casing and Hood
Trade Prices
Approx. Shipping Weight
D-8030-SA 30' C-8034-SA 34*
943 1024
128,200 $225 .*0 3205 139,300 300.50 T355
871.50 24.50
101 8247.00 1306 113 325.00 1408
STANDARD EQUIPMENT--Finishing collars, vapor pan, poker, nuts and bolts. Smoke Tees for Clifton Steel Furnaces:
-------------------------------------------------------------1--0-*------8--4--.-0--0---T--r-a-d--e---P---r-ic--e--------------------------------------------------------------
ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page S11-12
____________SQUARE METAL JACKET___________
Furnace Number
Diam. Shell
tt Rating Square Inches
Btu Capacity
at Registers
Furnace with Square Jacket and Flat Hood
Trade Prices
Approximate Shipping Weight
tD-520-SQS tO-522-SOS D-524-SQS D-527-SQS
20'
596
81,000
8120.00
1015
22*
622
84,600
142.00
1062
24*
696
94,600
162.00
1145
27*
741
100,800
197.00
1255
STANDARD EQUIPMENT--Square Metal Jacket with inner liner, finishing collars, poker, nuts and bolts.
Furnace is equipped with three steel chutes for firing from rear or left or right hand side, fire brick lining and supports. Metal plates and gaskets are provided to seal chutes not used.
When stoker is to be installed in front or below base of furnace, the above models cannot be used and hand fired models as shown on page 5 should be ordered less grate assembly and ash pit door.
fNOTE: These sizes equipped with steel chutes on right and left tide only.
NOTE: Sufficient space is not available on the standard hood for the total rating to be used by a number of small pipe take-offs. For such a condition 12* pipe take-offs with "Y" connections may be used.
NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered, without bxtra charge. The Arlington "Square" is furnished only with straight side flat top hood which is a part of the jacket
ttSEE PAGE 3--`'CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT
REGISTERS."
-.
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT.
7 SE-4
1 1
i1
i
! ; ; } i;
iJ ; !:
If
Gas Fired
HEATING EQUIPMENT
Sunbeam Furnaces
Furnace Number
SGA-65 SGA-80
SG-105 SG-120 SG-140
SUNBEAM GAS FIRED FURNACES
SHAWNEE -- Steel Heating Element Catalogue Page S18-T9, 29
For Use with Manufactured, Natural or Mixed Gas; L. P. Gas and Butane-Air Gas (525 Btu 1.16 Sp. Gr.)
A.G.A. Rating Btu Input per Hour
65,000 60,000 105,000 120,000 140,000
Btu Capacity at
Registers
36,560 45,000 59,060 67,500 76,750
ttRating Square Inches
268 331 435 496 579
Trade Prices with Standard
Equipment
Control Com bination GF-1, GF-2 or GF-4
$109.50 118.00 129.00 137.00 162.50
Approx. Shipping Weight
270 303 361 407 477
FACTORY ASSEMBLED.
Standard Equipment Includes:
Metal Jacket.
Series No. 500 Baso Automatic
Steel Heating Element.
Pilot Valve.
Pilot Filter and Gas Pressure Regulator (Except for L. P. Gas). Ribbon Burners.
Manual Shut-off Valve.
Draft Hood.
Control Combination as specified.
Control Combination GF-1 For Use vrith Manufactured, Natural or Mixed Gas. Detroit No. 411-CH Plain Thermostat. Detroit No. V-570-M Automatic Gas Valve and
Transformer.
Control Combination GF-2 For Use with Manufactured, Natural or Mixed Gas. MH No. T-81-A Plain Thermostat. MH Solenoid Gas Valve and Transformer? V-635-0 except for SG-120 and SG-140 for Mfd. Gas. . V-S4-C for SG-120 and SG-UO.for Mfd. Gas.
Control Combination GF-4
For Use with L. P. Gas or Butane-Air Qas (525 Btu 1.16 Sp. Gr.) (Arranged for 100% Safety Shut-off)
Detroit No. 411-CH Plain Thermostat. Detroit Automatic Gas Valve and Transformer:
No. V-570-M for Butane-Air (525 Btu 1.16 Sp. Gr.) No. V-571-M for L. P. Gas.
CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT.
OPTIONAL EQUIPMENT
Add to Above Trade Prices
No. LA-119-A Limit Switch (Airstat) for MH Controls (Catalogue Page S2B)...
$ 7.43
No. CA-805 Air Limit Control for DL Controls........................................................
7.35
ttSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS."
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.
Instructions tor Ordering Orders must specify (1) Control Combination desired.
(2) Type of Gas. (If L. P. Gas, whether Butane or Propane). (3) Heat Value of Qas--Btu (at 60F. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gas. (6) Elevation at point of Installation if in excess of 2000 feet.
RATINGS INDICATED ABOVE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2000 FEET. FOR RATINGS FROM 2000 FEET TO 5200 FEET AND ABOVE, REFER TO CURRENT LITERATURE.
SE-4
(J.
9
03663
Sunbeam Floor Furnaces
AMEBiCAN-<tada*d HEATING EQUIPMENT
Gas Fired
SUNBEAM GAS FIRED FLOOR FURNACES
SAGINAW --Steel Heating Element . Catalogue Page S20-21, 30
Fur nace No.
O-20 0-35
A.G.A. Rating
For Use with Mfd., Nat. or
Mixed Gas
For Use with L. P. Gas
Btu Input per Hour
Btu Output
per Hour
Btu Input per Hour
Btu Output
per Hour
20,000 14,000 20,000 14,000 35,000 24,500 35,000 24,500
For Use with Butane-Air Gas
525 Btu, 1.16 Sp. Gr.
Btu Input per Hour
Btu Output . per Hour
20,000 14,000
Trade Prices with Standard Equipment
With Control Combi nation
A
(33.00 .41.45
With Con trol Combi nation
B
(38.00 46.45
With Con trol Combi nation
C
With Con trol Combi nation
E
(50.60* (56.50 59.05* 64.95
App. Ship ping Wgt.
110 135
Welded Steel Heating Element. Outer and Inner Casing. Floor Register. Control Combination as specified.
Standard Equipment Includes:
Burner, Piping, Lighting Rod.' Gas Pressure Regulator (Except for L. P. Gas.) Draft Hood.
Control Combination A -- Manual Control with Locking Dovloo
Control Combination B--Manual Control with Baso Automatic Pilot
For Use with Mfd., Nat, or Mixed Gas.
For Use with Mfd., Nat., Mixed or L. P. Gas.
Main and Pilot Gas Cocks. Pilot Burner.
No. 831-1 Baso Thermostatic Main and Pilot Valve--(100% "Shut-ofT).
Pilot Burner.
Control Combination C -- Gonoral Controls Solf-Energlzlng Sot
*For Use with Mixed Gas (800 Btu Minimum Con tent) or Natural Gaa only.
Control Combination E--Mlnneapolls-Honeywcll Y-77-C Low Voltage Sot
For Use with Mfd., Nat, Mixed, or L P. Gas.
Main and Pilot Gas Cocks. T-80-1 Thermostat. B-60-6 Automatic Gas Valve. PG-6 Pilot Generator. 30 Ft. Two-wire Cable.
No. 831-1 Baso Automatic Main and Pilot Valve--(100% ''Shut-off'*).
Pilot Burner. No. T-81-A Plain Thermostat. No V-835-0 Solenoid Gas Valve and Transformer. 30 Ft Two-wire Cable.
IMPORTANT NOTE: Specify ONLY Control Combination B or E for Use with Liquefied Petroleum Gas or Butane-Air Gas, 525 Btu, 1.16 Sp. Gr. Deduct (3.35 from Trade Prices shown above for omission of Gas Pressure Regulator when specified for L. P. Gas.
CONTROL COMBINATION BY LETTER DESIGNATION MUST BE SPECIFIED WITH EACH UNIT
Instructions for Ordering Orders must specify (1) Control Combination Deaired.
(2) Type of Gas. (If L. P. Gas, whether Butane or Propane.) (3) Heat Value of Gas--Btu (at 60F. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gaa. (6) Elevation at point of Installation if in excess of 2,000 feet.
' RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2,000 FEET. FOR ELEVATIONS ABOVE 2,000 FEET, RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL.
9 SE-4
1
i
f I
j
i i
03664
Hand Fired
AMSICAN-($tai!davd Sunbeam Winter Air
hiatihg equipmiit
Conditioners
SUNBEAM WINTER AIR CONDITIONERS
HAND FIRED
Unit Number D-5520 D-5522 D-5524 D-5527
ALLERTON -- Steel Heating Element Catalogue Page S34-37
Btu Capacity at Registers 86.100
107,300 120,000 127,900
Trade Prices with Standard Equipment
$186.00 208.00 238.00 278.00
Approximate Shipping Weight
1205 1256 1370 1538
Unit Number D-3080 C-3480-B
CLIFFDALE -- Steel Heating Element Catalogue Page S38-40
Btu Capacity at Registers
Trade Prices Including Smoke Tee end
Standard Equipment
162,500 177,000
$376.00 457.00
Approximate Shipping Weight
2219 2432
Squire Mete) Jacket Inner Casino and Rings.
Standard Equipment Includes;
Blower Cabinet. Blower, Belt and Pulleys. Rubber Mounted Motor with overload protection.
Air Filters.
NOTE: OL No. CA-610 or MH No. LA-412-A Blower Switch--single pole can be furnished if desired, and if specified on order, at additional Trade Price of $8.40.
Q>
NOTE: Blower cabinets on Allerton and Cfiffdaie Units can be attached to either right or left side of heating jacket.
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR TEMPERATURE CONTROL EQUIPMENT.
SE-4
10
W
03665
Sunbeam Winter Air AMEBiQUt-ij'tflmIflwl
Conditioners
^ mmc eqtomeot
OH Fired Stoker Fired
SUNBEAM WINTER AIR CONDITIONERS
OIL FIRED
ALLERTON -- Steel Heating Element Catalogue Page S34-36
For use with Gun or Rotary Type Burnera
Unit Number D-5522-G or R D-5524-G or R D-5527-G or R
Btu Capacity at Registers
107,300 120,000 127,900
Trade Prices with
Standard Equipment
(208.00 238.00 278.00
Approximate Shipping Weight
1027 1139 1250
CLIFFDALE --Steel Heating Element Catalogue Page S38, 40
For use with Gun or Rotary Type Burners
Unit Number
Btu Capacity at Registers
Trade Prices Including Smoke Tee and Standard Equipment
Approximate Shaping Weight
O-30SO-G or R C-3480-GB or RB
162,500 . 177,000
(376.00 457.00
1775 1919
IMPORTANT: When ordering specify whether for use with Gun (Gj or Rotary (R) Type Burner. For Gun Type 8urner, Units will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, Units will be equipped with cast iron hearth rings and brackets, hearth plate, fire box liners and mineral wool insulation. Grates and Fire Brick are not furnished. Special fire doors and burner doors are supplied.
SEE PAGE 17 FOR ARCOFLAME OIL BURNERS AND CONTROLS; PAGE 18 FOR CORRECT SIZE
ARCOFLAME OIL BURNERS TO BE USED WITH THESE UNITS.
________
STOKER FIRED ALLERTON-- Steel Heating Element _______ Catalogue Page S34-36_______
Unit Number
D-5522-SA D-5524-SA 0-5527-SA
Btu Capacity at Registers
107,300 120,000 127,900
Trade Prices with
Standard Equipment
(208.00 238.00 278.00
Approximate Shipping Weight
1184 1284 1407
CLIFFDALE -- Steel Heating Element _______ Catalogue Page S38, 40_______
Unit Number
Btu Capacity at Registers
Trado Prices including Smoke Tee and Standard Equipment
Approximate Shipping Weight
D-3080-S C-3480-S8
162,500 177,000
(376.00 457.00
2033 2215
Unit is equipped with three steel chutes for firing from rear or left or right hand side, firs brick lining and supports. Metal plates and gaskets are provided to seal chutes not used.
when stoker is to be installed in front or below base of unit, the above models cannot be used and hand fired unite as shown on page 10 should be ordered less grate assembly, ashpit door, and hand firing accessories. *NOTE: These units equipped with steel chutes on right and left side only.
Square Metal Jacket. Inner Casing and Rings.
OIL FIRED OR STOKER FIRED Standard Equipment Includes:
Blower Cabinet. Blower, Belt, and Pulleys. Rubber mounted motor with overload protection.
Air Filters.
NOTE: Blower cabineta on Allerton and Cliffdate Models can be attached to either right or left side of heating jacket.
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT. 11
SE-4
('
i
I
03666
Oil Fired
J\illERICAltfSunbeam Winter Air
heatihg equipment
Conditioners
SUNBEAM WINTER AIR CONDITIONERS
OIL FIRED WINTERGLO ARCOFLAME OIL HEATING UNITS
FACTORY ASSEMBLED AND PRE-WIRED Steel Heating Element with Blower under Heating Compartment
Unit Number
Burner Model Number
Oil Firing Rate
Gals, per Hr.
Btu Capacity at
Bonnet
Trade Prices with Standard
Equipment
Approx. Shipping Weight
1203-OB 1205-OB
MF-S MF-S
.85* 1.00
85,000 . 105,000
$297.50 312.00
561 572
1.00 Gallon Nozzle furnished. *Pump Factory set at 80 lbs. pressure. The Wlnterglo Unit has Heating Element and Blower Unit enclosed in a single jacket.
Standard Equipment Includes:
Square Metal Jacket.
Air Filter.
Inner Lining.
Draft Stabilizer.
Blower, Belt and Pulleys.
High Temperature Steel Heat Lib-O-Rator
Rubber Mounted Motor with
Combustion Chamber.
Overload Protection. .
Master Control Switch.
Model MF-S Special Flange Type Arcoflame Oil Burner and Nozzle, CA-701 Stack Control; 41t-CH Ther
mostat. CA-816 Blower and Limit Control.
NOTE: Detroit 411-CDN Day-Night Heat Compensated Thermostat and 772 Tern-Clock Combination
may be substituted for 411-CH Thermostat -- if desired, so specify on order and add $17.63 to the above
Trade Prices. -
.The WINTERGLO Unit, with Its special flange type Arcoflame 0(1 Burner, is listed fer closet or alcove Installation by Underwriters' Laboratories, Is approved for Installation with loss than standard clearance And may be Installed en combustible flooring.
WINTERGLO WINTER AIR CONDITIONER FACTORY ASSEMBLED AND PRE-WIRED Steel Heating Element with Blower under Heating Compartment
Unit Number
1203-0 1205-0
Oil Firing Rate
Gals, per Hr.
.85 1.00
Btu Capacity at
Bonnet
85,000 105,000
Trade Prices with Standard
Equipment
$177.90 192.40
Approx. Shipping Weight
472 483
Squlrft Mtll Jiek.L inner Lining. Blower, Belt and Pulleys. Rubber Mounted Motor with
Overload Protection.
Standard Equipment Includes:
Air Filter. High Temperature Steel Heat Lib-O-Rator
combustion Chamber. Master Control Switch.
NOTE: Detroit CA-816 Blower and Limit Switch (Short Shank) can be furnished if desired, and if speci fied on order, at additional Trade Price of $14.46.
When furnished lees Arceflame Oil Burner, It Is recommended that unit be fired at th# specified firing rate, end with an ell burner which complin with Commercial Standards CS-76.
I NOTE: WINTERGLO Units are regularly furnished with niter frame which may be located on either side. If desired, and ao specified on order, special air filter base for bottom return air inlet will be substituted at no additional charge.
_ SEE PAGE 20 FOR HUMIOIFYING EQUIPMENT.
SE-4
12
03667
Sunbeam Winter Air Conditioners
AMEHiCAN-c^taudatfd HEATING EQUIPMENT
Oil Fired
SUNBEAM WINTER AIR CONDITIONERS
OIL FIRED
SARATOGA and WESTMORELAND ARCOFLAME OIL HEATING UNITS Steal Heating Element Catalogue Page S41-46
Unit Number
Burner Model Number
Nozzle Size Gallons per Hour
Btu Capacity at Registers
Trade Prices with Standard
Equipment
Approximate Shipping Weight
E-11WJ-F B-1124-6A B-1127-BA
B-I134-BC-18-M
B-1134-8C-18-K B-M34-BC-21-K
M-S C-1S CMS C-1S X
L-1S . L-1S
1.25* 1.50 2.00
2.50 3.00 3.50
95,000 150,000 200,000
240,000 285,000 330,000
$317.60 409.70 499.20 545.20 572.20 618.20
1130 1552 1833 2174 2265
2401
Set pump 80-90 lbs. pressure. The Saratoga, No. E-1120-F, has Heating Element and Blower enclosed in single Jacket. The Westmore
land Units have Heating Element enclosed in a separate Jacket and Blower enclosed in a cabinet which can be attached to either right or left side of Heating Jacket
Standard Equipment Includes:
Square Metal Jacket' Inner Lining. Blower, Belt, and Pulley*. Rubber Mounted Motor with Overload
Protection. . ...
Air Filter*. Draft Stabilizer. Heat Lib-O-Rator Molded Refractory Combustion
Chamber.
ARCOFLAME Oil Burner and Noz2te; CA-701 Stack Control; No. 20 Control Set (411-CH Thermostat. CA-615 Blower and Limit Control).
NOTE; Detroit 411-CDN Day-Night Heat Compensated Thermostat and 772 Tom-Clock Combination may be substituted for 411-CH Thermostat in No. 20 Control Set; the suffix "A" after Control Set Number will designate this substitution. If desired, add $17.63 to the above Trade Prices.
SARATOGA and WESTMORELAND -- Steel Heating Element Catalogue Page S4M5
Without Oil Burner or Controls
Unit Number
E-1120-F B-1124-BA B-1127-8A B-I134-BC-1S-H B-1134-BC-IS-W B-1134-BC-21-K
Recommended Nozzle Size Gallons per Hour
1.25 1.50 2.00 2.50 3.00 3.50
Btu Capacity at Registers
95,000 150,000 200,000 240,000 285,000 330,000
Trade Prices with Standard
Equipment
$186.00 264.00 352.00 398.00 410.00 456.00
Approximate Shipping Weight
876 1263 1521 1861 1679 2014
Standard Equipment Includes:
Squira Matal JackaL Inner Lining. Blower, Belt, and Pulley*. Rubber Mounted Motor with Overload Protection.
Air Filters. Mineral Wool Insulation. Refractory Brick.
SEE PAGE 17 FOR ARCOFLAME BURNERS AND CONTROLS; PAGE 18 FOR HEAT LIB-O-RATOR COMBUSTION CHAMBERS; PAGE 20 FOR HUMIDIFYING EQUIPMENT.
13 SE-4
03668
f
Gas Fired
heating equipment
Sunbeam Winter Air Conditioners
o
SUNBEAM WINTER AIR CONDITIONERS
SENECA -- GAS FIRED -- Catalogue Page S47-48, 60 Steel Heating Element -- With Blower at Right of Heating Compartment
Unit Number
SL-65 SL-105 SL-125 SL-150
For Use with Manufactured, Natural or Mixed Gat; L. P. Gas and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.)
A.G.A. Rating Btu Input per Hour
65,000 105,000 125,000 150.000
Btu Capacity at
Registers
57,600 71,400 85,000 102,000
Trade Prices with Standard
Equipment
Control Combinations AC-1, AC-2 or AC-4
6166.00 196.00 225.00 246.00
Approx. Shipping Weight
414 463 505 590
WYANDOTTE -- GAS FIRED -- Catalogue Page $49-50, 60 -- FACTORY ASSEMBLED Steel Heating Element -- With Blower Under Heating Compartment
Unit Number
For Use with Manufactured, Natural or Mixed Gas; L. P. Gas and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.)
A.G.A. Rating Btu Input per Hour
Btu Capacity at
Bonnet
Trade Prices with Standard
Equipment
Control Combinations AC-1, AC-2 or AC-4
Approx. Shipping Weight
SUA-55 SUA-70 SUA-85 SUA-105
55,000 70,000 85,000 105,000
44,000 56,000 66,000 64,000
8174.00 182.00 192.00 203.00
295 393 423 500
Standard Equipment Includes:
Metal Jacket. Steel Heating Element. Pilot Filter and Gas Pressure Regulator (except for L. P. Gas). Manual Shut-off Valve. Series No. 500 Baso Automatic Pilot Valve. Control Combination as Specified.
Air Filters. Ribbon Burners. Draft Hood. Blower-Motor Unit.
Control Combination AC-1
Control Combination AC-2
Control Combination AC-4
For Use with Manufactured, Natural or Mixed Gas
For Use with Manufactured, Natural or Mixed Gas
For Use with L. P. Gas or ButaneAir Gas (525 Btu, 1.16 Sp. Gr.) (Arranged for 100% Safety Shut-off)
Detroit No. 411-CH Plain
MH No. T-61-A Plain Thermostat. Detroit No. 411-CH Plain
f
Thermostat.
MH Solenoid Gas Valve with
Detroit No. V-570 Automatic Gas Transformer:
Thermostat. Detroit Automatic Gas Valve and
Valve with Transformer.
V-835-A except for SL-125 and Transformer:
Detroit No. CA-615 Blower and
SL-150 for Mfd. Gas.
No. V-570 for Butane-Air Gas
Limit Switch.
V-84-A with SL-125 and SL-150
(525 Btu, 1.16 Sp. Or.)
for Mfd. Gas.
No. V-571 for L. P. Gas.
MH No. LA-101-A Blower and Detroit No. CA-815 Blower and
Limit Switch.
Limit Switch.
CONTROL COMBINATION BY NUM8ER MUST BE SPECIFIED WITH EACH UNIT.
WYANDOTTE Units are regularly furnished with filter frame which may be located on either side. If desired, and to specified on order, special Air Filter Base for bottom return air inlet will be substituted at no additional charge.
SEE PAGE 20 FOR COMBINATION "S" FLOAT HUMIDIFIER; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.
Instructions for Ordering Orders must specify (1) Control Combination desired.
(2) Type of Gas. (If L. P. Gas, whether Butane or Propane.) <3) Heat Value of Gae--Btu (at GOT. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gas. (6) Elevation at point of Installation if in excess of 2,000 feet.
RATINGS INDICATED ABOVE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2.000 FEET. FOR RATINGS FROM 2,000 FEET TO 5,200 FEET AND ABOVE, REFER TO CUR RENT LITERATURE.
SE-4
14
03669
Sunbeam Winter Air American-g^taitdard
Conditioners
heating equipment
SUNBEAM WINTER AIR CONDITIONERS
MOHAWK -- GAS FIRED Catalogue Page S51-54, 60 Cast Iron Heating Element
Unit Number
tK-60 K-80 K-100 K-120 K-150 K-180 K-200 K-240
ttK-300
For Use with Manufactured, Natural or Mixed Gas; L. P. Gaa and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.)
A.G.A. Rating Btu Input per Hour
60,000 80,000 100,000
120,000 150.000 180,000
200,000 240,000 300,000
Btu Capacity at
Registers
40,800 54,400 68,000
81,600 102,000 122,400
136,000 163,200 204,000
Trade Prices with Standard
Equipment
Control Combinations AC-2, AC-3* or AC-4
6212.00 235.00 260.00
290.00 330.00 375.00
405.00 457.00 542.00
Approx. Shipping Weight
527 765 847
905 1239 1246
1557 1605 1883
Standard Equipment Includes:
Metal Jacket.
Manual Shut-off Valve.
Cast Iron Heating Sections.
Air Filters.
Pilot Pifter antf Gas Pressure Regulator (except for L. P. Gas).
Ribbon 8urnert.
Blower-Motor Unit.
Draft Hood.
Series No. 322 Baso Automatic Pilot Valve for each section for Manufactured, Natural
and Mixed Gas--(Control Combinations AC-2 and AC-3).
Series No. 500 Baso Automatic Pilot Valve (arranged for 100% Safety Shut-off for
L. P. Gas and 8utane-Air Gas, 525 8iu, 1.16 Sp. Or.)--(Control Combination AC-4).
Control Combination as specified.
Control Combination AC-2
Control Combination AC-3
Control Combination AC-4
For Use with Manufactured, Natural or Mixed Gee
For Use with Manufactured, Natural or Mixed Gas
For Use with L. P. Gas or ButaneAir Gas (525 Btu, 1.16 Sp. Gr.)
(Arranged for 100% Safety Shut-off)
MH No. T-81-A Plain Thermostat. MH Solenoid Qas Valve and
Transformer: V-835-A on K-60 through K-
100 for Mfd. Gas; on K-60
through K-150 for Nat. and Mixed Gas. V-84-A for remainder of Mo hawk units. MH No. LA-101-A Blower end Limit Switch.
Detroit No. 411-CH Plain Thermostat.
Detroit No. V-574 Step Acting Automatic Gas Valve with Me chanical Limit Control and Transformer, Manuel Opening Feature, Automatic Recycling.
hodDetroit No. CA-810 Blower Switch.
Note: K-60 furnis with No. V570 Automatic Gas Valve end No. CA-815 Blower end Limit Switch.
Detroit No. 411-CH Plain Thermostat
Detroit No. V-574 Step Acting Automatic Qas Valve with Me chanical Limit Control and Transformer. Manual Opening Fea ture, Automatic Recycling. (Special for L. P. Gas.)
Detroit No. CA-810 Blower Switch.
Not available with K-60.
tK-60 Unit not evailsble for use with Butane-Air Gas. For L. P. Gas, K-60 Trade Price indicated above includes MH No. T-11-A Plain Thermostat, V-155-A Gas Valve, LA-101-A Blower and Limit Switch and epecial Control for
100$! Safety Shut-off,
ttK-300 Unit not available for use with Butane-Air Gae.
K-80, K-IOOend K-120 Units are available with Push Button Electric Ignition, on special order, with control combination AC-3 for Manufactured, Natural or Mixed Gas. When desired, specify control combination AC-3E and add $15-00 to Trade Price of Unit with AC-3 controls.
CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT.
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.______________ ______________________________________________________ .
Instructions for Ordering Orders must specify (1) Control Combination desired.
(2) Type of Gas (If L. P. Gas, whether Butane or Propane). (3) Heat Value of Gaa.--Btu (at $0F. and 30 inches Ho). (4) Pressure available at outlet of Gas Meter. (5) Specific gravity of Gas. (6) Elevation at point of Installation If in excess of 2,000 feet.
RATINGS INDICATED A80VE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS UP TO 2.000 FEET. FOR RATINGS FROM 2,000 FEET TO 5,200 FEET AND ABOVE, REFER TO CURRENT LITERATURE.
15 SE-4
03670
/
Gas Fired
heating equipment
Sunbeam Winter Air Conditioners
* - Unit Number
KUA-60
SUNBEAM WINTER AIR CONDITIONERS
CHIPPEWA --GAS FIRED --FACTORY ASSEMBLED Catalogue Page S55, GO
Cast Iron Heating Element With Blower Under Heating Compartment
For Use with Manufactured, Natural or Mixed Gas; L. P. Gas and Butane-Air Gas (525 Btu, 1.16 Sp. Gr.)
A.G.A. Rating Btu Input per Hour
60,000
Btu Capacity at
Bonnot
4S.000
Trade Prices with Standard
Equipment
Control Combinations A-7, A-16 or A-17
$224.00
Approx. Shipping Weight
500
Standard Equipment Includes:
Metal Jacket. Cast Iron Heating Element Pilot Filter and Gas Pressure Regulator (except for L. P. Gas). Manual Shut-off Valve.
Blower-Motor Unit. Air Filter*. Ribbon 8urner. Draft Hood.
Series No. 500 Baso Automatic Pilot Valve (arranged for 100% Safety Shut-off for L. P. Gaa and Butane-Air Gas, 525 Btu, 1.16 Sp. Gr.)--(Control Combination A-17).
Control Combination as specified.
Control Combination No. A-7
Control Combination No. A-1$
For Use with Manufactured, Natural, or Mixed Gas. For Use with Manufactured, Natural, or Mixed Gas.
MH No. T-81-A Plain Thermostat.
MH No. V-835-A*Solenoid Gas Valve and
Transformer.
....
MH No. LA-101-A Blower and Limit Switch.
Detroit No. 411-CH Plain Thermostat. Detroit No. V-574 Step Acting Automatic Gas Valve - with Mechanical Limit Control and Transformer,
Manual Opening Feature, Automatic Recycling. Detroit No. CA-810 Blower Switch. *
Control Combination No. A-17
For Use with L. P. Gas or Butane-Air Gas (525 Btu, 1.16 Sp. Gr.)
Detroit No. 411-CH Plain Thermostat. Detroit Electric Gas Valve and Transformer:
No. V-571 for L. P. Gas. No. V-570 for Butane-Air Gas (525 Btu, 1.16 Sp. Gr.) Detroit No. CA-81S Blower and Limit Switch.
The Chippewa Unit is available with Push Button Electric Ignition, on special order, with control combination A-16 for Manufactured, Natural or Mixed Gas. When desired, specify control combination A-16E and add $15.00 to Trade Price of Unit with A-16 controls.
CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT.
The Chippewa Unit is regularly furnished with filter frame which may be located on either side. If desired, and so specified on order, special Air Filter Base for bottom return air inlet will be substituted at no additional charge.
SEE PAGE 20 FOR HUMIDIFYING EQUIPMENT; PAGE 21 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.
Instructions for Ordering Orders must specify (l)Control Combination desired..
(2) Type of Gas, (If L. P. Gas, whether Butane or Propane.) (3) Heat Value of Gaa--Btu (at 60*F. and 30 inches Hg). (4) Pressure available at outlet of Gas Meter. (5) Specific Gravity of Gaa. ' - (6) Elevation at point of Installation if in excess of 2,000 feet.
RATINGS INDICATED ABOVE ARE FOR INSTALLATIONS AT SEA LEVEL AND AT ELEVATIONS
UP TO 2.000 FEET. FOR RATINGS FROM 2,000 FEET TO 5,200 FEET AND ABOVE, REFER TO CUR
RENT LITERATURE.
.,
SE-4
T
<
03671
Arcoflame Burners
AMBICAN>(^tlttMlai*4 HEATING EQUIPMENT
Arcoflame Burners
ARCOFLAME OIL BURNERS
COMPLETE WITH STANDARD ARCOFLAME BURNER CONTROL SET AND NOZZLEt
Catalogue Page S46 (A Standard Arcoflame Burner Control Set Must Be Purchased With Each Arcoflame Burner)
Model Number C-1S
C-2S
With Control Set Number
Contents of Arcoflame Standard Control Sets
19 No. 411-CH Thermostat. For Gravity Furnaces No. CA-805 Air Limit Control.
20 For Winter Air
Conditioners
No. 411-CH Thermostat. No. CA-81S Combination Blower and Limit Control.
Trade Prices $124.50
130.70
C-3S
For Use on 116 Volt, 60-Cycle Current MAXIMUM CAPACITY 3.00 GALLONS OIL PER HOUR
Approximate Shipping Weight 140 pounds
L-1S
. 19 For Gravity Furnaces
20 For Winter Air
Conditioners
No. 411-CH Thermostat. No. CA-805 Air Limit Control.
No. 411-CH Thermostat
-'
No. CA-315 Combination Blower and Limit Control.
$137.50 143.70
L-3S
For Use on 116 Volt, 60-Cycle Current MAXIMUM CAPACITY 7.00 GALLONS OIL PER HOUR
Approximate Shipping Weight 165 pounds
IMPORTANT: When substitution of 411-CDN end 772 combination is made for 411-CH such control sets will be designated by suffix "A" after control set number. If desired, add 117.63 to above Trade Prices.
IWhen ordering Arcoflame Oil Burner be sure to specify Nozzle size desired.
IMPORTANT NOTICE
Trade Prices for Arcoflame Burners and Standard Burner Control Sets as shown above include, in addition to the Nozzle and Controls as listed, a No. CA-701 Arcoflame Stack Control.
Arcoflame Burners will be sold only when ordered in combination with one of the Arcoflame Standard Burner Control Sets, as shown above. Additional Arcoflame Controls may be purchased separately at Trade Prices shown below.
When Arcoflame Burner is ordered with Nozzle Sizes of 1.25 and 1.35 Gallons per Hour, Special Turbulator Attachment is furnished at no additional charge.
Arcoflame Oil Burners are approved by the National Board of Fire Underwriters and comply with Commercial Standards CS-75.
IMPORTANT NOTE: Motors and Controls regularly furnished are for 115 Volt, 60 Cycle A. C.
CONTROLS FOR ARCOFLAME OIL BURNERS Catalogue Page S61-62
Trade Prices -- When Ordered Separately
Stock Number
Description Standard Controls--115 Volt, 60 Cycle
Trade Prices
CA-701 411-CH
411-CDN 1411-TD
*772 CA-805 CA-815
CA-610 CA-295
Detroit Heat Compensated Thermostat Low Voltage (Scale 40-90eF.)............ Detroit Day-Nipht Heat Compensated Thermostat (Scale 40*-90F.)....... ......
Detroit Air Limit Control (High Voltage) (Scale 100S-300F.) (Stop 250'F.)----Detroit Combination Blower and Limit Control (HiQh Voltage) (Scale Blower
75*-225, Limit 100-300, Stop 200 F.).............................................................. Detroit Relay Transformer.....................................................................................
<27.00 8.55
: 9.45 1.35
16.73 7.35
14.48 8.78
41I-CDN Thermostat is used only in combination with 772 Tam-Clock. {Order 411-TD and 772 Tarn-Clock to convert existing 411-CH Plain Thermostat to Automatic Day-Night
operation,~
17 SE-4
I
03672
Arcoflame Oil Burners
AMERlCAN-e^taitdatHl HEATING EQUIPMENT
Combustion Chambers
ARCOFLAME CONVERSION OIL BURNERS
FOR USE WITH SUNBEAM GRAVITY FURNACES
KENWOOD
A-1018-CD or BD A-104O-CD or BD A-1044-CD or BD A-104S-CD or BD A-I052-CD or BO
ARLINGTON ANO ARLINGTON "SQUARE"
C-2S' C-3S C-3S C-3S C-3S
D-520-0 or D-S20-SOQ D-522-G or D-522-SOG D-524-G or D-S24-SOQ 0-527-0 or D-527-SQQ
CLIFTON
C-2S C-2S C-2S C-2S
D-8030-Q C-8034-O
C-2S L-3S
FOR USE WITH SUNBEAM WINTER AIR CONDITIONERS
ALLERTON
CLIFFDALE
D-5520 D-5622-G D-5524-G D-5527-G
C-2S C-2S C-2S C-2S
D-3080-G C-3480-GB
C-2S L-3S
Combustion Chamber* not furnished. See Arcoflame Oil Burner Installation and Service Guide for sug gested size and shape.
NOZZLES AND STRAINERS
FOR CONVERSION OIL BURNERS
For Model C
For Model L
Gals, per Hr. Spray Angle Gals, per Hr. Spray Angle
FOR SARATOGA ANO WESTMORELAND UNITS
Unit Number
Gala, per Hr. Spray Angle
1.25
1.35 1.50 1.65 1.75 2.00 2.25 2.50 2.75 3.00
80* 80* 80* 80* 60* 60* 60* 60* 60* 60*
3.00 3.50 4.00 4.50 5.00 5.50 6.00 $.50 7.00
60* E-1120-F
1.25*
60* B-1124-BA
1.50
60* B-1127-BA
2.00
60*
B-1134-BC-18-H
2.50
$0* B-1134-BC-18-K 3.00
60* B-1134-BC-21-K 3.50
60*
60*
60
80
60 80* 45 60 60
Set Pump at 80-90 lbs. pressure if 1.25 Nozzle is used. When these Nozzles are used in Model "C" Arcoflame Burners, the Special Turbulator Attachment should be used. Special Turbulator Attachment furnished at no additional charge when these nozzles ere supplied as part of one of the Standard Arcoflame Burner Control Sets shown on page 17.
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS FOR SARATOGA and WESTMORELAND UNITS
Trade Prices --When Ordered Separately
Stock Number
Sunbeam Unit Number
Max. Gale, per Hour
Trade Prices
0S 1S 2S
3S SE-4
E-1I20-F
B-1124-BA
B-1127-BA B-1134-BC-18-M
B-1134-BC-18-M B-1134-8C-21-H
18
1.50 1.75 2.25
3.75
612.00 15.00 16.50
18.50
i
i
l i!
I. It
03673
Air Filters
AAKBICAN-e$tattdaff<! HEATING EQUIPMENT
Blower-Filter Units
SUNBEAM BLOWER-FILTER UNITS
With Cabinet and Filters Catalogue Page S22-27
Unit Number
0-1- 9 D-1-10H D-1-12 D-1-15
1-18-F8 1-21-FB
Diameter of Wheel
9* 10H' 12* 15* 18* 21*
Motor Horsepower
1/6 1/4 1/4 1/3 1/* 3/4
Trade Prices
$ 60.00 66.00 76.00 114.00 172.00
230.00
Approx. Shipping Weight
142 146 181 241 478 633
NOTE: OL No. CA-810 or MH No. LA-412-A Blower Switch--single pole can be furnished if desired, end if specified on order, at additional Trade Price of 88.40.
Filter Sizes
20* x 25* 20* x 20* 16* x 25* 16* x 20' 15* x 20* 10* x 20*
AIR FILTERS FOR REPLACEMENT
Catalogue Page S57
Trade Prices Each
1* Thick
*0 86 .66 .80 .80 .80 .70
2* Thick
81.33 1.16 1.16 1.16 1.16 .97
NOTE: Filters as shown at left are packaged in cartons of twelve (12) of
minimum quantity.
03674
Humidifying Equipment
HEATING EQUIPMENT
Sunbeam
Humidifier Number
HUMIDIFYING EQUIPMENT
Description
Trade Prices
FOR GRAViTY FURNACES:
WA Catalogue Page S28
-
Automatic Drip Humidifier: Self-contained Heat Actuated Peed Valve Assembly, Metal Pan,
Shut-off Valve, Water Line and Couplings.
Water Pan for ARLINGTON "SQUARE" Water Pan with Cast Iron Frame that attaches to Jacket
8 9.25 8 3.50
FOR WINTER AIR CONDITIONERS:
H-4* Catalogue Page 558
S-400 Catalogue Page S58
Automatic Spray Humidifier: (For use with alt Winter Air Conditioners
except Seneca and Wyandotte Units) No. H-14 Friez Humidiatat No. V-837-A Solenoid Water Valve including Transformer. 2 No. 390 Water Strainers. No. 26 Water Pressure Reducing Valve. No. 50 Assembly including: Tubing and Fittings, Shut-Off Valve, 4
Spray Nozzles with individual Shut-Off Valves. Spray Pan with capacity Adjusting Plate. Nozzle Cleaning Rod, 3 Rubber Caps for Spray Nozzles not in use.
Float Humidifier: Evaporating Plates. Evaporating Pan. Water Reservoir with Float and Valve. Flexible Tube and Pipe Clamp Valve. S-401: For SUA-55; K-60; KUA-60. S-402: For 0-6520, 0-5522, D-5524; 1203-08,-0; 1205-08,-0;
E-1120-F; SL-85, SL-105, SL-125, SL-150; SUA-70, SUA-85, SUA-105; K-60, K-100, K-120, K-150. S-403: For D-5527; B-H24-BA; K-180, K-200, K-240. S-404: For D-3080; B-1127-BA; K-300. S-405: For C-3480-B; B-1134-BC-18-H.-18-K,-21-KExtra Evaporating Plates, Trade Price Each 8.17
Water Pan for AULERTON, CLIFFDALE, SARATOGA and WESTMORELAND
Water Pan with Cast Iron Frame that attaches to Jacket.
845.00
811.65 11.65 12.75 13.75 15.00
8 3.50
: SE-4
20
03675
r(0
Sunbeam
AMERICAN-<$tattdawl
heating equipment
Temperature Control Equipment
Combination
Description
Trade Prices
FOR ALL HAND FIRED GRAVITY FURNACES:
M-x Catalogue PageS29
A-li Catalogue Page S28
Mechanically Controlled MH Metaphram Draft Control.
A self-contained mechanical draft and check regulating instrument.
Thermostatically Controlled MH No. T-81-A Plein Thermoetet. MH No. LA-119-A Limit Switch (Alretet). MH No. M-S7-A Otmper Motor with Transformer.
No. 933 Accessories (Cheln, S-Hooks end Pulleys).
* a.4o *33.15
FOR ALL HAND FIRED WINTER AIR CONDITIONERS:
Mechanically Controlled
M-x
MH Metaphram Draft Control.
Catalogue PageS59
A self-contained mechanical draft and check regulating instrument.
Catalogue PageS59
No. CA-810 DL Blower Switch. No. LA-412-A MH Blower Switch (Furnacestat).
When Room Thermostat Draft Controls are not used, a blower switch is necessary for starting and stopping blower when bonnet temperature rises or fails. When controls as listed in Combination 8-1X below are used, blower switch is included in control equipment.
B-lx Catalogue PsgeS59
Thermostatically Controlled MH No. T-81-A Plain Thermostat MH No. LA-101-A Blower and Limit Switch (Furnacestat). MH No. M-87-A Damper Motor with Transformer.
No. 933 Accessories (Chain, S-Hooks and Pulleys).
B-6x
Same as above except with substitution of MH No. T-847-AChronothenr for No. T-81-A Plain Thermostat
* 8.40 8 8 40
8 40
*40.20 *57.83
OPTIONAL THERMOSTATS
OPTIONAL THERMOSTAT--Description
Extra* Trade Prices
For Use only with
Unit
Control Combi nation No.
Replaces i
411 -CON Day-Night Heat Compensated Thermostat AND 772 Tern-Clock
*17.63
SHAWNEE SENECA and \ WYANDOTTE/ MOHAWK
CHIPPEWA
GF-1 or GF-4 AC-1 or AC-4 AC-3 or AC-4 A-16 or A-17
411-CH Plain Thermostat
T-801-A Tim-0-SUt T-847-A Night and Day Electric Clock
Thermostat (Chronotherm)
* 5.93 *17.63
) SAGINAW SHAWNEE SENECA and l WYANDOTTE/ MOHAWK
(CHIPPEWA
E GF-2 AC-2 AC-2 A-7
These Extra* to be added to Tnds Prices of Units. Do not epply if ordered sapariiely-
T-81-A Plain Thermostaf
to
AUTOMATIC NIGHT TURN DOWN ASSEMBLY
No. Description
411-TD Night Turn Down
assembly AND 772 Tern-Clock
Used to convert existing 411-CH Plain Thermostat to automatic Day-Night operation
Trade Price *18.08
For Use only with
Unit
Control Combi nation No.
SHAWNEE SENECA end 1 WYANDOTTE/
MOHAWK CHIPPEWA
GF-1 or GF-4 AC-1 or AC-4 AC-3 or AC-4 A-1 $ or A-17
- 21
` SE-4
|
/ /
03676
S :=i.-.w;M'sr.i Water Heaters
AMEBICAN-e^tattdaifd
heating eqdipmeht
Gas Fired Automatic Storage
GAS FIRED AUTOMATIC STORAGE WATER HEATERS
Heater No.
204-S . 304-S 404-S
GALVANIZED STEEL Temperature and Pressure Relief Valve, $4.00 Trade Price Extra
AMERICAN BUDGET {For Um with.Manufactured, Natural or Mixed Gas)
Capacity Gallons
Btu Input
Recov. Gals, per Hour 60 Rise
WITH ANODE
Trade Prices
Approx. Shipping Weight
LESS ANODE
Trade * Prices
Approx. Shipping WeiQht
20
20,000
28.0
646.90
171 643.40
166
30
26,000
36.4
57.75
214
54.25
209
40
30,000
42.0
78.50
245
75.00
240
- Heater No.
204-S 304-S 404-S
Capacity Gallons
20 30 40
(For Usa with Liquefied Petroleum Gas)
Btu Input
Recov. Gals, per Hour ` . 60 Rise
WITH ANODE
Trade Prices
Approx. Shipping Weight
19,000 26,000 30,000
26.6 36.4 42.0
650.40 57.75 82.00
171 214 245
LESS ANODE
Trade Prices
Approx. Shipping
Weight
646.90 54.25 78.50
166 209 240
Models for Liquefied Petroleum Gss are furnished with special thermostat and safety pilot to provide for 100% shut-off of gas to both the main burner and the pilot burner in the event of pilot failure.
Heater No.
(For Use with Butane-Air Gaa: 52$ Btu, 1.16 Sp. Gr.)
Capacity Gallons
Btu Input
Recov. Gala, per Hour 60 Rise
WITH ANODE
Trade Prices
Approx. Shipping Weight
LESS ANODE
Trade Prices
Approx. Shipping
Weight"
204-S 304-S 404-S
20
19,000
26.6
650.40
30
26,000
36.4
57.75
40
21,000
29.4
82.00
171 646.90 214 54.25 245 78.50
166 209 240
Gas Inlet I.P.S.
Center Flue-Connection 3*
Size of Water Connection
HIGH ALTITUDE (2000-5200 feet) RATING FOR NO. 304-S FOR USE WITH MANUFACTURED, NATURAL, MIXED AND LIQUEFIED PETROLEUM GASES, INCLUDING BUTANE-AIR (525 Btu, 1.16 Sp. Gr.)-24,000 Btu INPUT; RECOVERY GALLONS PER HOUR. 60 RISE-33.6.
RATINGS SHOWN FOR NO. 204-S ANO NO. 404-S ARE FOR SEA LEVEL. RATINGS SHOULD BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1.000 FEET ABOVE SEA LEVEL.
SE-4
22
03677
/
o
V
03678