Document 68XxXnVdYRbr1LEmjQ9n4pj3

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS 77 WEST JACKSON BOULEYARD CHICAGO, ILLINOIS 60604 DATE: SUBJECT: FROM: THRU: TO: JUN O~ 2019 CLEAN AIR ACT INSPECTION REPORT LSC Communications, Inc. (LSC), Pontiac, Illinois Eleanor Kane, Enviromnental Engineer AECAB (Ml/WI) Sarah Marshall, Section Chief AECAB (Ml/WI) File BASIC lNFORMATION Facility Name: LSC Communications, Inc. (LSC) Facility Location: 1500 North Main Street, Pontiac, Illinois Date of Inspection: May 7, 2019 EPA Inspectors: 1. Eleanor Kane, Environmental Engineer 2. Victoria Nelson, Environmental Engineer Other Attendees: 1. Danny Buck, Operations Manager, LSC 2. Bill Stefanski, Maintenance Supervisor, LSC 3. Bryan Bannister, Regional Environmental Health and Safety, LSC (by phone) Contact Email Address: bryan.a.bannister@lsccom.com Purpose of Inspection: Evaluate compliance with the Clean Air Act, including the facility's synthetic minor limits for the Title V program and otherwise-applicable NESHAPs Facility Type: Magazine Printir,g Arrival Time: 9:15am Departure Time: 11 :00am Inspection Type: ISi Unannounced Inspection 0 Announced Inspection OPENING CONFERENCE ISi Credentials Presented ISi CBI warning to facility provided The following infom1ation was obtained verbally from Mr. Buck or Mr. Stefanski: Company Ownership: The facility was acquired by LSC Communications in October 2016. Prior to that it was owned by R.R. Donnelly & Sons. Process Description: The facility prints a variety of short-run magazines on eight printing lines, five of which are double web and three of which are single web. At each line, ink is applied to the paper in several stages and the ink is dried in a series of ovens. Volatile Organic Compound (VOC) emissions from the printing areas and the ovens from seven of the lines are all routed to a single regenerative thermal oxidizer (RTO). The eighth line has a dedicated RTO controlling ink application and ovens. The printed papers are folded, bound and trimmed in the bindery either on stitching machines (no adhesive) or patent binding machines (with adhesive). Staff Interview: Staff reported that the printing lines cannot be operated unless the associated RTO is at temperature. Staff did not recall the last time the RTO was tested, since regular emissions testing is not required under the facility's FESOP. Monthly usage of inks and solvents is tracked to demonstrate compliance with facility-wide emission limits. TOUR INFORMATION EPA toured the facility: Yes Photos and/or Videos: were taken during the inspection. An optical gas imaging camera was used to evaluate the capture and control ofVOC emissions. One video was taken at the RTO stack. Page 2 of3 CLOSING CONFERENCE Requested documents: Most recent stack testing at the RTO RTO temperature records for 2019 12 months of HAP/VAC tracking MSDS/TDS for highest volume inks and solvents SIGNATURES Page 3 of3 Facility Name: LSC Communications, Inc. (LSC) Facility Location: 1500 North Main Street, Pontiac, Illinois Date ofJnspection: May 7, 2019 APPENDIX A: DIGITAL VIDEO LOG 1. Photographer Name: ""i;T.;,--.-1,-,_-,,,;r, ""t..._T,-,J,-,,--.,_-:;.u,. ;,' i"'--~V.l. ..1:...:..~ .l ~~ .._.._L,:.V..l..l. 3. Company/Facility Name: LSC Communications, Inc. (LSC) 5. Number of Videos: I 2. Date of Inspection: "fl,.f,".-,,,, .'7 ..'Hi.1 0 . ,L..~J ; :> ..:...,.,.1. .../ 4. Street Address, City, State: 1500 North Main Street, Pontiac, Illinois 6. Archival Record Location: C:\Users\Vnelson\OneDrive - Environmental Protection Agency (EPA)\Targeting and Inspections\LSC Communications\ FLIR Videos I Video Number I 1 I File Name I MOY 2423.mp4 I Date I 51712019 Description of Video RTO Stack _J Appendices Page 1 of 1