Document 65q0O1M59xMG9KYb9OkEBeKXd

HEATING VENTILATING AIR CONDITIONING GUIDE 1940 Centrally located ceiling or wall type supply openings arranged for completely diffusing the air consist of several round, hollow, cone-shaped flaring members placed in the proper relationship to each other. The velocity of emergence of the air from the unit can be made practically uniform over the entire surface of the supply opening, and the velocity in any direction may be varied to any desired value by adjusting the position of the cones. One or more of the smaller flaring members act as ejectors and injectors which draw a small proportion of the room air into the air spreader where it mixes with the conditioned air before it is dis charged. An idea for producing even distribution of air consists of a perforated ceiling made of a suitable architectural surface and installed a small distance below the normal ceiling level'of the room. In the space provided by this suspended ceiling a plenum chamber is formed into which the conditioned air is introduced. From the plenum space the air is permitted to diffuse through the large number of small ceiling openings into the room. BALANCING SYSTEM In designing an air conditioning system, it should be the aim of the engineer to so proportion the duct system that proper distribution of air to every supply opening will be obtained. Since this is almost impossible to accomplish in practice, it becomes necessary to have means of balancing the system to secure the desired amount of air in each space. There are a number of ways in which this may be accomplished, some of which are: 1. Dampers on the supply and return grilles. 2. Dampers in the supply and return ducts. 3. Reducing the effective area of some supply openings by blank-offs. 4. Combinations of dampers in both supply and return air. Dampers on the supply grilles themselves are objectionable because of their effect on the air stream. Dampers on the return grilles are frequently helpful in building up a static pressure in the room to prevent infiltration of outside air, and at the same time reduce the volume of incoming air. However, it is frequently impossible to sufficiently reduce the incoming air by this method alone. A damper in the supply duct some distance back of the supply opening forms a very satisfactory means of regulating the flow without disturbing distribution across the supply opening face. A damper in the return air duct has the advantage over one immediately behind the grille in that it does not tend to create high localized velocities through the grille as the latter might do if nearly closed. Blank-offs consisting of pieces of sheet metal covering a portion of the supply opening face can frequently be used satisfactorily, although determination of just what is required is a matter of experiment, and the balancing of the system is not nearly so conveniently accomplished as with dampers. Dampers in both supply and return air form the most flexible means of controlling the supply to the room and the static pressure within the room. When feasible, these dampers, particularly those in the supply ducts, should be a substantial distance from the supply opening, and ahead of the acoustic duct lining if used. Due consideration should also be given to the use of the several volume control and uniform distribution devices now available. See Catalog Data Section. 542 Chapter 30 AIR DUCT DESIGN Pressure Losses, Friction. Losses, Friction Loss Chart, Propor tioning the Losses, Sizes of Ducts, General Rules, Procedure for Duct Design, Air Velocities, Proportioning the Size for Friction, Main Trunk Ducts, Velocity Method, Equal Friction Method, Duct Construction Details THE flow of air due to large pressure differences is most accurately stated by thermodynamic formulae for air discharge under condi tions of adiabatic flow, but such formulae are complicated, and the error occasioned by the assumption that the gas density remains constant throughout the flow may be considered negligible when only such pressure differences are involved as occur in ordinary heating and ventilating practice. In the development of the formulae, diagrams, and tables for the flow of air, use is made of the following basic equation for the flow of fluids: If ffv he the velocity head in feet of a fluid, and the velocity, V, be expressed in feet per minute, the fundamental equation is V = 60 y2g Hv The factor g is the acceleration due to gravity, or 32.16 ft per second per second. It is usual to express the head in inches of water for ventilating work and, since the heads are inversely proportional to the densities of the fluids, Hv = 62,4 hy i or 12 therefore, IIv = 5.2 ha V = 1096.5 y~- (1) where V -- velocity in feet per minute. K = velocity head or pressure in inches of water. d = weight of air in pounds per cubic foot. For standard air (70 F and 29.921 in. barometer) if = 0.07492 lb per cubic foot. Sub stituting this value in Equation 1: K = 1096.5 ^o^ = 405 {TT (2) 543