June 16, 1977
RECTO JUN 201977
TENNESSFE EASTMAN COMPANY
A Division of Eastman Kodak Company KINGSPORT, TENNESSEE 37662 615 246-2111
Mr. W. Ronald Hoopes Chairman, Workpractices Subcommittee W. R. Grace & Company 55 Hayden Avenue Lexington, Mass. 02373
Dear Ronald:
Our people have reviewed the Guidelines completely and think your committee has done an excellent job.
We have had one or two incidents related to peroxide formation from vinylidene chloride and therefore we suggest reinforcing the warning.
We would suggest adding the following statement in section E. Control Methods:
Caution Vinylidene chloride may form a white, solid peroxide which when dry may explode upon minor impact. Any pipe or other equipment which may be contaminated with peroxide should be wet with water or 5% sodium hydroxide to remove the peroxide.
Also, in section 2 Safety Precautions of the analytical portion add:
Caution Vinylidene chloride may form a white, solid peroxide. Do not use glass-stoppered bottles for liquid samples or standards. Discard liquid vinylidene chloride after 30 days. Attach a label to liquid samples and standards stating that it may form a hazardous peroxide.
Yours truly,
John R. McDonough, M. D Medical Director
rw
SIl 088422