Document 65Rjpdro6DEXk353je66M7qnd
bcc: AG Eades
Buchanan JS__n_d__Street - m Roush
DETR&t T - JG~ificks~
CHI4AGO - DL Hosmer
Iw T,
M . . ' ;
Mr. F. Vaclavlk, Project EsgjBMr Parke, Davie It Company 102 Howard Street Holland, Michigan
Dear Mr. Yaci&vikl
/
Here is the analysis result of your recent sample of THERM INOL FR-2s
PROPERTY Moisture ppm Viscosity & 190* F,
eeatipoiee Acid Number mgKOH/gm
sample
210
99 0,9
NEW THERhUNOLFR-2 SO max.
Y5 max. 0.91 max.
Aside from the elevated viscosity which indicates some thermal degradation
of the fluid, the most significant number is the high moisture content of the
sample. High moisture In the system can cause fluid breakdown indirectly.
The moisture flashes to steam and ia the pump casing this steam pocket
causes impeila to cavitate, reducing flow through the heater arith the
consequence of high film temperatures and localised overheating of the fluid.
This thermal breakdown also causes hydrogen chloride gat to be released.
The hydrogen chloride dissolves la the moisture, producing hydrochloric
acid and this would explain the accumulation of iron chlorides plugging the
sight glass piping*
terv'^
^
t note you have this System blanketed with nitrogen, This is not necessary with a truly oxidationretittaut fluid such as THERmINOL, Our usual recommendation is to vent the expansion tank outdoors to the atmosphere. This will allow an exit point for any hydrogen chloride gas or moisture that is formed.
DSW 343619
STLCOPCB4096635
Mr. F. Vaclavik June 7. 1?&5 Page 2
This iufortaatioa it explained la greater detail la the enclosed copy of
sar 7HEMlHOL IF Design Guide--Page IS* Also included la this
reference Is s technique for allowing condensible aad/or aon-condenslble
vapors to reach the expansion tank vent more rapidly. This is done by
installing a small diameter bypass Una on & discharge aide of the jpump
to the top Of the expansion tank* A needle or globe valve for controlling
flew le Installed in this line and flow ie adjusted so the expansion tank ia
maintained at some elevated temperature just above the boiling point of
water (slightly above 212*F.). Gaea the acidity and moisture are vented
from the System, you may continue to operate with this same batch of
Cluid. However. I suggest you send a sample to my attention in approxi
mately another month so we can see If the viscosity increase is acceler-
*****
; . -v
-
Let me know if 1 can help further.
Sincerely.
S. Shaw Market Specialist Functional Fluids
Enclosure
ccs Mr. B. Breitman American Hydrotherm Corp, 10-55 Jackson Blvd.
T r.Ww. Naw Yfirk
:
STLCOPCB4096636