Document 65Kmr07QaamzyQ7DZg8w1w891

MONSANTO COMPANY ANNISTON PLANT STANDARD OPERATING INSTRUCTIONS FOR PYRANOLS December 1967 DEFENDANT'S EXHIBIT t CS>N WATER PCB-SD0000051755 MONSANTO COMPANY ANNISTON PLANT STANDARD OPERATING INSTRUCTIONS FOR PYRANOLS Copy No. /^ Prepared by: M. J. Williams Prod. Foreman V. R. Haupt Prod. Supervisor H. L. WilljLams Prod. Superintendent Date Issued: December 1967 ? DSW 543058 WATER PCB-SD0000051756 OPERATING INSTRUCTIONS FTRANOLS DISTRIBUTION Plant Manager Production Superintendent -Production Supervisor Maintenance Superintendent Technical Services Department Standards Department 1 Copy 1 Copy 10 Copies 1 Copy 1 Copy 2 Copies DSW 543059 WATER PCB-SD0000051757 OPERATING INSTRUCTIONS FYRANOLS INDEX SECTION A - SYNOPSIS OF PROCESS SECTION B - SAFETY AND HOUSEKEEPING SECTION C - DETAILED INSTRUCTIONS (PROCESS FUNCTION OUTLINE) I. Pyranol Mixes II. Process Diagram III. Description of Process IV. Comments on Process SECTION D - EMERGENCY PROCEDURE DSW 543060 WATER PCB-SD0000051758 - SYNOPSIS OP -7'-. ? ' - - t-. ? t<ttc MI) Av* ..friijrV:-- .-b _ ' ... - :1 . 0S* 506' WATER PCB-SD0000051759 OPERATING INSTRDCTIOMS PTRAMOLS STBOPSIS OF PROCESS 1. General , . '"V Most Pyranols are produced by the mixing of distilled Aroclor with various other rav materials. Some of the Pyranols are treated with attapulgus earth and filtered prior to loading for shipment. There are three Pyranols blends that are pro duced by the mixing of distilled Aroelors only. . The quality of each mix is analyzed by the Laboratory, and vhen approved, it is loaded into tank cars or drawn out into drums. 2. Mix Tank Area . There are two mix tanks used in ,tjie production of Pyranol mixes. One is a 12,000 gallon tank and the other is a 2,000 gallon tank.` Each tank is equipped with an agitator. Sales demand for some of the mixes does not warrent production of large mixes, which accounts for the second, or small, mix tank. All mixes produced in the large tank are filtered through a Sparkler, filter. Mixes produced in the small tank, which are not treated with attapulgus earth, are packaged in drums only, and filtered through a diaper cloth sock on the end of the drum-out line. DS\N 543062 WATER PCB-SD0000051760 SAFETY AND DSW 543063 WATER PCB-SD0000051761 OPERATING INSTRUCTIONS AROCLOA SAPETT AND HOUSKEEEPINC Safety of operatlona In the Afoolotf PDant depends on the individual operator. Materials being handled and operations must be observed closely to guard against the following: Cause and Action to Prevent 1. Chlprine Gas Chlorine gas is a very toxic corrosive gas. Leaks or high pressure can occu^ to liberate it. Action to Prevent a. Report Chlorine gas exposure immediately for treatment with Antidote. Milk may be used in mild cases to relieve throat irritation. Oxygen from the resuscitator in the Dispensary is available. b. Keep gas mask in good condition. Keep a good canister in the mask. Use these type masks only in chlorine concentrations to 2-3X chlorine in air. c. Use a Scott Air Pak in concentrations of chlorine gas above 3Z in air. Three units are available in the Aroclor-Biphenyl . Department. d. If caught in chlorine gas without a mask, hold your breath and go cross wind until you are out of range of the-gas. Place ' a handkerchief over your nose in small quantities of chlorine. e. Report all chlorine leaks for repair Immediately. Make temporary repairs with tape if possible'. f. In case of a major chlorine leak, the source of chlorine gas must be stopped. Notify the Chlorine Plant immediately if the pressure on the chlorine manifold exceeds 30 psig. Cut off liquid chlorine from the car. DSW 543064 WATER PCB-SD0000051762 Aroclors . Safety & Housekeeping 2. Thermal Buns 2. Cause and Action to Prevent Contact with hot uninsulated product lines at the chlorinators and still areas. Contact with uninsulated steam lines and open steam. .. Contact with hot Aroclors from broken lines or leaks. Contact with open flames at stills or from heating lines in the department. Action to Prevent a. Know that contact with equipment and product will cause a thermal burn due to the high temperatures. Hake changes in operations with this hazard in mind. b. Know the first aid treatment for burns. Cold Water Treatment (See Appendix A Emergency Section). c. Wear gloves and long sleeve shirts with the sleeves rolled down when operating. Gloves and clothing can make the difference between first and second degree burns. d. Report uninsulated lines for repair of insulation. e. Use only steam lines with hose and hose clamps in good condition. f. The following operations are hazardous and should be done with care: (1) Catching samples at the Aroclor chlorinator circulating pumps. (2) Sampling the Solid Aroclor still receiver. (3) Drawing bottoms on the Aroclor stills. OSVJ 5*3065 "WATER PCB-SD0000051763 Aroelors Safety & Housekeeping 3. Explosion 4. Palls 3. Cause and Action to Prevent An explosion could occur in the chlorinators by slugging liquid chlorine to the distributor. Slugs of liquid chlorine could react fast enough to cause excessive pressure in the vessel. A rupture of the chlorinator could occur. Action to Prevent . a. Observe operation of the chlorine vaporiser and do not let liquid chlorine get into the rotameters. Pipe lines will be frosted. b. In case chlorine feed lines are frosted, close liquid chlorine feed valve to the ! vaporiser. Check steam addition to the vaporizer. Do not start up until source of trouble has been located. c. Do not close valve in water discharge line from the chlorinator coil. d. Observe temperature of the chlorinator periodically and be sure it is not too hot (180C. maximum). Slipping on cement floors, stairs, Aroclor on floor, ice conditions; tripping over objects (hose, pipe, valve handles, etc.); or losing footing on ladders, etc., can cause falls. Action to Prevent a. The majority of minor, serious, and nearmiss injuries in the Aroclor Dept, are the result of falls. Prevention is always within the ability of the operator by use of expert operating practices. DSW 543066 WATER PCB-SDO000051764 roclors Safety ft Housekeeping 4* fails (Contd.) 5. Fires 4. Cause end Action to Prevent b. The following items should be done: (1) Return hose to rack after using. ' / (2) Keepij^perAtlng areas clean of all : foreign objects. (3) Return ladders to racks when not in use. (4) Keep gloves on and hands out of pockets, especially going up stairs. (5) Place guards around Shy area that presents a hazard that should be . guarded. e. Poor lighting due to burned out bulbs should be corrected at once. Poor light ing due to inadequate facilities should be reported. d. Spills must be cleaned up imnedlately following their occurrence. Report any spill that cannot be cleaned up within the shift to the Chief Operator. Spills are to be reported in the log book. Fires can occur by: Biphenyl, Santowax R, or Santewax C ignition. Chlorine problems in the vaporizer allow ing reaction with steam to release hydrogen. Furnace burner backfire. Wood, rags, or paper on hot lines. Sparks from welding apparatus of open flames. OS* 567 WATER PCB-SD0000051765 Aroclora Safety & Housekeeping 5. Cause and Action to Prevent 5. Fires (Contd.) Action to Prevent ' *. . a. Area must be clear of trash or flammable _ ; materials. Use trash skips and cans. ; b. Smoke only In areas so designated. C. Use spark producing equipment only with a fire permit and proper inspection. d. Use care In lighting gas torch or the still furnaces. - a. fire fighting equipment Includes: (1) Two wheeled dry powder units. ' (2) Hose house with 200 ft. of hose. (3) Two dry powder hand extinguishers. One CO2 hand extinguisher. (4) Two 3/4" water hoses. (5) Bose connection north of Santowax. (6) Scott Air Paks. (7) Fire truck In fire house. f. Observe visitors in the plant and be sure they observe safety rules. qS\N 543068 WATER PCB-SD0000051766 Aroclors Safety & Housekeeping 6. 6. The following is a list of chemicals handled in the Aroclor Plant operations and the precautions to be taken during their handling: a. Chlorine Gas This is a corrosive gas which is toxic. Leaks or back pressure can occur and liberate chlorine gas in the area. Operators should have their cartridge type respirators handy at all times while in the area. Use of gas masks is explained in Section B.l. If you are caught without a gas mask, and large amount of chlorine gas are liberated, hold your breath and go ' cross wind until you are out of range of the gas. Once out of the area, obtain an emergency gas mask and return to the area and correct the trouble. A victim of chlorine gas fumes must be removed as quickly as possible from the gaseous area. Place patient on his back with head and back elevated. Milk may be used in mild cases as a relief from throat irritation. If the patient has stopped breathing, start artificial respiration immediately. b. Biphenyl Biphenyl is a flammable material which will burn. Burning should not be done in the presence of Biphenyl or Biphenyl vapors. The melting point is 68.7C., and the auto ignition temperature is 258C. Inhalation of Biphenyl fumes is not recommended, since it can cause a drugged effect on the person. c. Santowax R Santowax R is a flammable material which will burn. It is relatively non-toxic to human beings. However, the vapors of Santowax R are irritating to the mucous membranes and bronichial tract. Pro longed breathing of the vapors should be avoided. The melting point is 140C. dSNN 543069 WATER PCB-SD0000051767 Aroclors Safety & Housekeeping 6. (Continued) d. Santowax C e. Ferric Chloride f. Attapulgus Earth g. Hydrated Lime h. Crude Aroclors i. Hydrogen Chlorine Gas j. Still Bottoms or Residue 7. Same as Santowax R, since it is the crude ' material prior to distillation. Ferric Chloride is a black-brown solid. It causes only slightly irritating effects on the skin or mucous membranes. When heated it will decompose and release toxic fumes of Chlorine. It will react with water to produce toxic and corrosive HCl fumes. This material is a dried earth. No danger in handling. Wash off with water to clean. No particular hazard in handling this material. The dust is irritating to the eyes and skin, and should be washed off with water. - Crude Aroclors are hot, since all are handled in steam traced or jacketed lines. They can easily cause thermal burns in contact with the skin. Prior to air blow ing, the material has HCl fumes entrained in it which are irritating to the skin or mucous membranes. This is a corrosive gas which is toxic. It is irritating to the raucous membranes, to the eyes, and to the respiratory tract. It will react with water to form Hydro chloric Acid. Fumes from still bottoms are toxic. They are extremely irritating to the mucous membranes, to the eyes, and respiratory tract. 0S\N 543070 WATER PCB-SD0000051768 roelor k Pyranols Safety k Housekeeping 8. 7. Toluene 8. Xylene 9. Trichlorobensene 10, Tritetrachlorobehgene Toxicology: Acute poisoning, resulting from exposure to high concentrations of the vapors, is rare with Toluene. Inhalation of 200 ppm of Toluene for eight hours may cause impair ment of coordination and reaction time; vith higher concentrations (up to 800 ppm) these effects are increased and are observed in a shorter time. Toluene is handled in outside area and there is no high'concentration of vapors. Fire Hasard: Dangerous when exposed to heat and flame. Care should be taken not to heat Toluene above 100C from use of steam coll in mix tank. ' Same as Toluene. Toxicity: When heated to decomposition, trichlorobensene emits highly toxic fumes of chlorides; can react with oxidising materials. Fire Hasard: Slight; when exposed to heat and flame. Care should be taken not to heat trlchlorobensene above 120C from use of steam co.il in mix tank. Same as Trichlorobensene. dS\N 54307A WATER.PCB-SD0000051769 Arocl ors Safety & Housekeeping 9. HOUSEKEEPING The Aroclor chlorinator and still operators are responsible for house keeping during their shift. Good housekeeping is the mark of good operations, safety practices, quality, and costs. Housekeeping duties are equal in importance with all other operating duties. Por Practices Action to Prevent 1. Hoses, valve handles, dip stocks, rags, and other material on ground or floor. a. Replace after use. b. Have place to store all necessary operating sids. . c. Report needs to supervision. 2. Product Leaks. a. Tighten valve packing glands and flange bolts. b. Report leaks to Chief Operator for maintenance alteration. 3. Trash and Crude Drums. a. Contact Chief to have drums moved from area. b. Use trash skip in area. A. Product spills or clean out messes. a. Prevent necessity of clean-out by keeping tracing, insulation, or jacket in good repair by getting items turned in for maintenance work. b. Spills must be cleaned up when they are made. Clean up will continue through the following shifts to finish the job. OSNN 5072 ..WATER PCB-SD0000051770 oS>N 543073 WATER PCB-SD0000051771 OPERATING INSTRUCTIONS PYRANOLS . DETAILED INSTRUCTIONS PROCESS FUNCTION OUTLINE AROCLOR DEPARTMENT I. PTRANOL MIXES 1.1 Scope This covers the production of the various Pyranol Mixes. 1.2 Description of Process Distilled Aroclors, and other raw materials, are pumped to one of two pyranol mix tanks. These raw materials may come from a filtrate tank, storage tank, tank car, or drums. (See Table 1 for raw materials used In the production of each product or mix). Each mix tank is equipped with an agitator for thorough mixing. Quality of a pyranol mix is analysed by the Laboratory and when in specification, it is loaded into tank cars or drawn Into suitable containers. II. PROCESS DIAGRAM Attached. III. DESCRIPTION OF PROCESS 3.1 Charging of Mix Tanks A. Charges for Large (12,000 Gal.) Mix Tank 1. Pyranol A13B3B, Inerteen PPO, Inerteen 54201-KA, Thermlnol FR-0, and Therminol FR-Lo Temp., are produced in the large mix tank as these products are sold in tank car quantities as well as in drum lots. 2. Sampling of TCB and TTCB cars (a) After car has been spotted, by railroad crew or by use of our car spotter at HB-40 dock, open dome and take 2-1/2 gallon samples from car. (b) Label samples for complete analysis and send to the Laboratory. DS\N 543074 WATER PCB-SD0000051772 BY . ............ DATE.?.**//?}?7 CHKD. BY................ DATE...................... SUBJECT... Py^ANOL Ml*ES _ . FLOW 'p'EEf....... SHEET NO ..../_.......OF.../_____ JOB NO......................................... ....... TOLUENE X yi-E N E WATER PCB-SD0000051773 Detailed Inatruetiona Pyranols (\ 3. Transfer of Materials to Mix Tank 2 - (a) Connect TCB or TTCB car to the unloading pump. Ground car, line, and pump. (b) Set valves in line from car to the mix tank. (c) Check mix tank to be sure it is empty. (d) Check bottom outlet valve on tank to be sure it is closed. (e) Check Instruction sheet, as prepared by Super vision, for quantities of raw materials needed. (f) Start unloading pump and transfer TCB or TTCB to mix tank as specified after receiving okay from the Laboratory. Record tank measurement (outage) after transfer. (g) After this transfer has been made, blow out unloading line with nitrogen or air. (h) Circulate storage tank, containing Aroclor to be used, for a minimum of one hour. (i) Take 1/2 gallon sample of the Aroclor from storage tank and send to the Laboratory for analysis (Sp. Gr. and resistivity). (j) Set valves in line from Aroclor storage tank to the mix tank. 00 Start storage tank pump and transfer Aroclor to mix tank as specified, after receiving okay from the Laboratory. Record tank measurement (outage) after transfer. (1) Add dry attapulgus earth, as specified, to mix tank through nozzle on top of tank by use of a funnel and hand scoop. 4. Agitation.Circulation and Sampling (a) Start agitator and agitate tank for two hours , while using recycle line and by-passing the filter. DSW 543076 WATER PCB-SD0000051774 Detailed Instruction* Pyrano Is t V 3 (b) Set lines to filter press and circulate material through press for 30 minutes. (c) After circulating for 30 minutes, take 1/2 gallon sample. Label sample as specified on instruction sheet, and send to the laboratory. (d) Continue agitating and circulating the mix until results are received from the laboratory. (If the sample is out of specifications an adjustment must be made). (e) If the above sample Is okay by the laboratory, then add PPO or BP-221 as specified on the instruction sheet. (f) Set lines to filter press and circulate material through press for 30 minutes. (g) After circulating for 30 minutes, take three 1/2 gallon samples. Label samples for complete analysis and send to the laboratory. (h) If the material is okay by the laboratory it is loaded into a tank car or drawn out into designated containers. (1) When a tank car is loaded take two 1/2 gallon samples from car for lot number. When drums are filled take two 1/2 gallon samples, from drums for lot number. B. Charges for Small (2,000 gallon) Mix Tank 1. Pyranols 1254 - 10% Toluene, 1260 - 10X Toluene, 1262 10% Toluene, 1262 - 10% Xylene, Santiciaer 794, and a Special Aroclor Blend are produced In the small mix tank. 2. Transfer of materials to mix tank. (a) Circulate storage tank, containing Aroclor to be used, for a minimum of one hour. (b) Take 1/2 gallon sample of the Aroclor from storage tank and send to the laboratory for analysis. (o) Set valves in line from Aroclor storage tank to the mix tank. DSW 543077 ... WATER pcb_SD0000051775 Detailed Instructions Pyranols 4 (d) Get accurate measurement of Aroclor storage tank. (e) Check instruction sheet, as prepared by supervision for quantities of raw materials needed. (f) Start storage tank pump and transfer desired amount of Aroclor to the mix tank after receiving okay from the laboratory. (g) Place Toluene or Xylene drums to be used near small pump under mix tank. (h) Sample each drum of Toluene or Xylene, using thief, to be sure it is clear and free of water. (i) Set valves in line from Toluene pump to mix tank. (j) Place pipe, attached to flexible hose at pump, in drum, ground drum, and start pump. (k) Change drums as necessary in order to pump desired quantity into mix tank., (l) Start agitatorand agitate for one hour. (m) Take 1/2 gallon sample. Label sample for proper identification and send to the laboratory for analysis. (n) Continue agitating the mix until results are received from the laboratory. (If the' sample is out of specifications, an adjustment must be made). (o) If the above sample is okay by the laboratory, then draw out in Aroclor drums. DS* WATER PCB-SD0000051776 Detailed Instructions Pyranols ' 5 IV. COMMENTS OH PROCESS -o Do not allow temperature on mix tanka to exceed 120 C. TCB and TTCB Vlll begin to vaporise above this temperaute. The large pyranol mix tank is calibrated In outage whereas other tanks are calibrated in innage. All drums filled with pyranol mixes containing toluene are ' stenciled,TOLUOL rather than Toluene. When a tank car is loaded from the large pyranol mix tank, samples are taken from the car and analysed for lot number. If the remaining material In the mix tank Is drawn out in drums, then samples must be taken from the drums and analysed for another lot number. The area, where pyranol mixes are produced Is considered a part of the Aroclor Department and these mixes are made by Aroclor operators. The large Pyranol tank can be blown with nitrogen whenever moisture content Is too high. It has been extremely difficult to get Inerteen 54201-KA to meet electrical specs at'times. To prevent recurrence the following techniques are followed and Included on the instruction sheet. 1. TCB would be earth treated to bring power factor below a value of ten. 2. TCB plus 1254 mix would be earth treated until power factor was below a value of one. 3. Ether would be added only after earth had been filtered out and filter cleaned. 4. Tank car would be loaded only when power factor was a value of three max. 5. Most Important, nitrogen would be blown into mix tank through the bottom nozzle during the earth treatment to supplement the extremely poor agitation system presently employed. OS\N 543079 WATER PCB-SD0000051777 DSW 543080 I R8Y1 WATER PCB-SD0000051778 CALIEHiVrXO O? PYPAE:OL MIXING TANK - Note: Outages measured from a point 10" above face of flange on second 2" nipple west of manhole. .? - i.,' k i i ' it ; * i *; i ? `, r t c*k ^ ^' --- fr i i \ t\ t i` : ( ir - c Outage Tn 18 . 19 20 . 21 22 23 24 25 26 27 26 29 30 31 32 33 34 35 35 37 33 39 40 41 42 43 44 45 46 47 4S 49 50 51 52 S3 54 55 56 57 . 53 59 60 *1 62 - : 63 . 64 65 66 Volume Gal. 12,565 12,473 12,382 12,290 12,199 , 12,107 12,016 11,924 11,833 11,741 11,650 11,558 11,467 11,375 11,284 11,192 11,101 11,009 10,918 10, 826 10, 735 10,643 10,552 10,460 10,369 10,277 10,183 10,089 9,995 9,901 9,807 9, 713 9,619 9,525 9,431 9,337 9,243 9,149 9,054 8,960 8, 866 8, 772 8,678 8,584 8,490 8, 396 8,302 8,208 8,114 ~ Outage In 67 68 69 70- 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Volume G3l. 8,020 7,925 7,830 7, 734 7, 639 7, 544 7,449 7,354 7, 258 7,163 7,068 6,973 6,877 6,782 6,687 6, 591 6, 497 6,401 6, 306 6, 211 6,116 6,021 5,925 5, 830 5, 735 5, 640 5,546 5,451 5,357 5,262 5,168 5,073 4,978 4,884 4,789 4,695 4,600 4,505 4,411 4,316 4,222 4,127 4,033 3,938 3,843 3, 749 3,654 3,560 3,465 Outage In 116 117 . 118 119 120 121 122 123 124 125 126 127 123 129 130 131 132 133 134 135 136 137 138 139 140 141 . 142 143 144 145 146 147 148 149 150 151 152 153 ` 154 155 156 157 158 159 160 .. 161 162 163 Volume Gal. - 3,372 3,279 3,185 3,092 2,999 2,906 2,813 2,720 2,626 2,533 2,440 . 2,347 2,254 2,160 2,067 1,974 1,881 1, 788 1,695 1,601 1,508 1,415 1,320 1, 225 1,130 1,036 (dish) 942 852 772 6S8 627 558 492 428 367 312 265 220 182 148 117 87 62 40 25 12 5. 0 54308^ oS>N WATERJPCB-SD0000051779 NEW PYRANOL MIX TANK Tank length measured from top of the flange to the bottom of the dish -119 Innage and outage measurements are from the top of the flange. InnageI Innage Innage Inches 1 Gals. Inches Gals. Inches Gals. Outage Outage Inches Gcil s Inches Outage Gals. Inches 2 12 3 33 4 44 5 . 56 6 69 7disl 85 8 105 9 125 10 145 11 165 12 185 13 205 14 225 15 245 16 265 17 285 18 305 19 325 20 345 21 265 22 385 23 405 24 425 25 445 , 26 465 27 485 28 505 29 525 31 565 32 585 33 605 34 625 35 645 36 665 37 685 38 705 39 725 40 745 41 765 42 785 43 805 44 825 . ',45 845 46 865 '47 885 48 905 49 925 50 945 51 965 52 985 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 75 76 77 78 79 80 81 82 83 84 85 86 - 87 88 89 90 91 92 93 94 95, 96 97 98 99 100 101 102 103 1005 1025 1045 1065 1085 1105 1125 1145 1165 1185 1205 1225 1245 1265 1285 1305 1325 1345 1365 1385 1405 1445 1465 1485 1505 1525 1545 1565 1585 1605 1625 1645 1665 1685 1705 1725 1745 1765 1785 1805 1825 1845 1865 1885 1905 1925 1945 1965 1985 2005 104 105 106 . 107 108 109 2025 2045 2065 2085 2101 2115 10 2115 60 1125. 110 11 2101 61 1105 111 12 2085 62 1085 112 13 2065 63 1065 113 14 2045 64 1045 114 15 2025 . 65 1025 115 16 2005 66 1005 116 17 1985 67 985 117 18 1965 68 . 965 118 19 1945 69 945 119 - 20 1925 ' 70 925 21 1905 71 905 22 1885 72 885 23 1865 73 865 24 1845 74 845 25 1825 75 825 26 1805 76 805 27 1785 77 785 28 * 1765 78 765 29 1745 79 745 30 1725 80 725 31 1705 81 705 32 1685 82 685 33 1665 83 665 34 1645 84 645 35 1625 85 625 36 1605 86 . 605 37 1585 87 585 38 1565 88 565 39 1545 89 545 40 1525 90 525 41 1505 91 505 42 1485 92 485 43 1465 93 465 44 1445 94 445 45 1425 95 425 46 1405 96 405 47 1385 97 385 48 1365 98 365 49 1345 99 345 50 1325 100 325 51 1305 101 305 52 1285 102 285 53 1265 103 265 54 1245 104 245 55 1225 105 225 56 1205 106 205 57 1185 107 185 58 1165 108 165 59 . 1145 109 145 DSW 543082 ! WATER PCB-SD0000051780 APPENDIX - INDEX Instruction Sheets for: 1. Xnerteen PPO 2. Inerteen 54201-KA 3. Pyranol A13B3B 4. Therminol FR-Lo Temp. 5. Therminol FR-0 . 6. Aroclor Blend - 1254-4465 7. Aroclor Blend - 1242-1246 8. Santiclier 794 9. 1254 - 10X Toluene 10. 1260 - 10Z Toluene 11. 1262-- 10Z Toluene 12. 1262 - 10Z Xylene qSW 543083 WATER PCB-SD0000051781 TO: CHIEF OPERATORS Date: INSTBDCTIONS FOR INERTEEN PPO LOT HO. Initial aa Completed . 1. Check the large Pyranol mix tank and be sure it Is clean. Drain any material into a drum. 2. Pump TCB from Tank Car ____________ to Pyranol tank, measuring" outage. 3. Pump 1260 from Ho. storage tank to Pyranol tank until you have a " outage in tank. 4. Add pounds of earth to tank and start agitating. 5. Agitate and circulate, by-passing filter, for two hours. 6. Blow tank contents with nitrogen to aid agitation and/or lowdr water content. 7. Circulate through filter for 30 minutes, then catch onehalf gallon sample. .8 Label the sample INERTEEN PPO. Send to Laboratory to check: Specific Gravity Refractive Index Specs. 1.560 - 1.568 <? 15.5C 1.6137-1.6147 <a 25C Moisture 30 ppm Chlorides 0.10 ppm 9. Continue agitating and circulating the mix until results of the analysis are received from Lab. (If the sample is out of specs, make adjustment.) ; .10 If sample is okay by the Lab, then clean the filter. .11 Add pounds of PPO (Olycldyl Phenyl Ether). 0S\N 543084 'WATER PCB-SD0000051782 INSTRUCTIONS FOR INERTEEN PPO LOT NO. 2 Initial aa Completed 12. After the PPO is added, agitate and circulate for two hours. 13. Circulate through filter for 30 minutes. Take three one-half gallon samples, label INERTEEN PPO LOT NO._ for complete analysis and send to Lab. 1A. If okay - ve will load: Tank Car Remainder in drums: 65 lbs. 360 lbs. 67A lbs. NOTE: PPO is toxic, avoid contact with skin and eyes. If any is splashed in eyes, wash with water and report to dispensary. Wash off any spills on skin with alcohol and follow with soap and water. Wear goggles and gloves when handling. August 1965 Rev. 1 - March 1967 oSVM 543085 WATER PCB-SD0000051783 TO: CHIEF OPERATORS DATE: INSTRUCTIONS FOR INERTEEN 54201-KA LOT NO. Initial as Completed 1. Check the large Pyranol mix tank and be sure it is clean. . ' Drain any material into a drum. 2. Pump TCB from Tank Car____________ measuring " outage. to Pyranol tank 3. Earth treat to bring power factor @ 60 cycles to 10 max. 4. Pump 1254 from No. storage tank to Pyranol tank until you have a " outage in tank. 5. Add 10 pounds of earth to tank and start agitating. 6. Agitate and circulate, by-passing filter for two hours. Blow tank contents with nitrogen to aid agitation and/or lower water content. 7. Circulate through filter for 30 minutes, then catch one-half gallon sample. 8. Label the sample Inerteen 54201-KA. Send to Lab to check for adding ether. 9. Continue agitating and circulating the mix until results of the analysis are received from Lab. (If the sample is out of specs, make adjustment), (if power factor @ 60 cycles is more than 1.0, earth treat with 10 lbs. by-passing filter. Take sample after two hours circulate and agitate, and 30 minutes filtering). 10. If sample is okay by the Lab, then clean the filter. 11. Add pounds of PP0 (Glycidyl Phenyl Ether). 12. After the PP0 is added, agitate and circulate for one hour. 13. Circulate through filter for 30 minutes. Take three one-half gallon samples, label Inerteen 54201-KA, Lot No. L for complete analysis and send to Lab. 14. If okay, (Power factor at 60 cycles must be 3.0 or lower), we will load tank car, remainder in drums 674 pounds. NOTE: PPO is toxic, avoid contact with skin and eyes. If any is splashed in eyes, wash with water and report to dispensary. Wash off any spills on skin with alcohol and follow with soap and water. Wear goggles and gloves when handling, DSW 543086 WATER PCB-SD0000051784 INERTEEN 54201-KA - SPEC SHEET CO O C ^-1 CL fu cn 00 U o ft) r0 o. o 'X a --1 O. S co O m a) CM CL -r CO 00 CO f-l CNJ mm HH co co ir> HH \> SO r-H H o cn CM m vO o mO o 1 O * 00 m om o in 1 1 1 1 00 CO .-t CM m in HH co co m HH vD sO HH o cn o cn CM m . vO oo o I 00 oo o . m 1 1 1 1 00 CM r-4 CM oo IsCO CO io 5 (0 Q oo cn -4 CM . oo 00 co -l CM m in * r--I H CO CO in n f-i r-* vO O HH o cn o r-l m o .o CM vD 1 00 m 1 11 1 1 1 in m a> o -a* m r--< r-H 1 1 o in 1 to 1 i 1 I1 1 cn t 1o 1 i 1 . 1 1 CM . ; O CO V CJ o. H co f * CJ 0) 4J E to i-4 QH om o r- co \> vD N m o m m ri . H . H H r4 H pH - oi 1I 11 > 4-> i-l u CJ oo > oo z CO z uo uo a, u u ft) Ko O 1-t >* CL, a, 4J . XJ AJ ` o iM> 1-1 U o O M-l O O to o ft) co 0) CO M Pn 1-1 tn 3o *rH 00 > a> i-i a 4J i-i Zz a X AJ M > H 03 u O tJ 0) to ft) V a; O i- o 4J o M CO or y-4 CL <U C 3 3Z o oo o CO 0) rH C i-4 u CO oS m CU 'D pH f~* c u cn z CO ?> 4J i-l CO o o CO H 1-1 CO >z O i) o Z zu o <11 c C 3 4J zw U QJ z 4J w WATER PCB-SD0000051785 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR PYRANOL A13B3B LOT HO. Initial aa Completed 1. Check the large Pyranol mix tank and be sure it is clean. Drain any material into a drum. 2. Pump TTCB from Tank Car ________________ to Pyranol tank, measuringM outage. 3. Pump 1260 from No. storage tank to Pyranol tank until you have a M outage in tank. 4. Add. pounds of earth to tank and start agitating. 5. Agitate and circulate by-passing filter for two hours. 6. Blow tank contents with nitrogen to aid agitation and/or lower water content. 7. Circulate through filter for 30 minutes, then catch one-half gallon sample, 8. Label the sample PYRANOL A13B3B. Send to Laboratory to check: Specific Gravity Refractive Index Specs. 1.563 - 1.571 <a 15.5C 1.6075-1.6085 <a 25C Moisture 30 ppm Chlorides 0.10 ppm 9. Continue agitating and circulating the mix until results of the analysis are deceived from Lab. (If the sample is out of specs, make adjustment.) 10. If sample is okay by the Lab, then clean the filter. 11. Add pounds of EP-221. 12. After the EP-221 is added, agitate and circulate for two hours. DSW 543088 WATER PCB-SD0000051786 INSTRUCTIONS FOR FYRAKOL A13B3B LOT NO. Initial as Completed 13. Circulate through filter for 30 minutes. Take three one-half gallon samples. label Pyranol A13B3B, Lot No. for complete analysis and send to Lab. 14. If okay we will load: Tank Car Remainder in drums: 65 lbs. 360 lbs. 374 lbs. 2 DSW 543089 WATER PCB-SD0000051787 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR THERKENOL FR-LO TEMP. LOT NO. Initial as Completed . 1. Check the large Pyranol mix tank and be sure it is clean. :Drain any material into a drum. 2. Pump TTCB from Tank C*r _________________ to Pyranol tank, measuring" outage. 3. Pump 1242 from No. storage tank to "Pyranol tank until you have a _" outage in tank. 4. Agitate and circulate, by-passing filter for two hours. 5. Circulate through filter for 30 minutes, then catch one-half gallon sample. 6. Label the sample FR-LO TEMP. Send to Laboratory to check: Specific Gravity Specs. 1.431 - 1.452 & 25C Moisture 75 ppm Viscosity 8.0 - 9.0 cp 7. Continue agitating and circulating the mix until results of the analysis are received from Lab. (If the sample is out of specs, make adjustment.) 8. If sample is okay by Lab., take two one-half gallon samples, label FR-Lo Temp., Lot No., for complete analysis and send to Lab. 9. If okay, we will load: Tank Car Remainder in drums: 55 lbs. 600 lbs. DSW 543090 WATER PCB-SD0000051788 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR THERMINOL PR-0 LOT NO. Initial as Completed 1. Check the large Pyranol mix tank and be sure It Is clean. Drain any material Into a drum.' 2. Pump TTCB from Tank Car to Pyranol tank, measuring" outage. 3. Pump 1242 from No. storage tank to Pyranol tank until you have a " outage In tank. 4. Agitate and circulate, by-passing filter for two hours. 5. Circulate through filter for 30 minutes, then catch one- half gallon sample. ' 6. Label the sample FR-0. Send to Laboratory to check: Specific Gravity Specs. 1.400 - 1.421 @ 25C Moisture 75 ppm Viscosity 10.5 - 12.5 cp 7. Continue agitating and circulating the mix until' results of the analysis are received from Lab. (If the sample is out of specs, make adjustment.) 6. If sample is okay by Lab, take two one-half gallon samples, label Therminol FR-0, Lot No. for complete analysis, and send to Lab. 9. If okay, we will load: Tank Car -, Remainder In drums: 60 lbs. 600 lbs. NOTE: PPO Is toxic, avoid contact with skin and eyes. If any Is splashed In eyes, wash with water and report to dis pensary. Wash off any spills on skin with alcohol and follow with soap and water. Wear goggles and gloves when handling. - DSW 543091 WATER PCB-SD0000051789 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR AROCLOR 1254-4465 BLEND LOT HO. Initial as Completed 1. Transfer 1254 fro* Ho. - storage tank to the small mix tank (Ho. 2). Reading nowX. Reading after transfer should beX In Ho. storage tank. (Heed 1,540 gallons) . 2. Have steam on Ho. 2 Pyranol mix tank if necessary to warm up 1254. 3. Add pounds of 4465 ( drums at 400 lbs. each, plus lbs.) Add slowly - keep agitator running. Due to fumes, it may be necessary to.cool tank with water. 4. Close manhole when finished. Agitate material for 8 hours. You-will probably need to put steam on tank jacket. 5. After 8 hours, take one-half gallon sample. 6. Label the sample Aroclor 1254-4465 Blend. Send to Laboratory to check: Specific Gravity Refractive Index Specs: 1.512 - 1.526 @ 65C 1.6400-1.6420 Viscosity at 210F 49 - 55 Color 2 Max. 7. If material is in specification, take two one-half gallon samples from drum-out line. 8. Drum out in 650 lb. drums net weight. Use a filter cloth to drum out through. DS\N 543092 WATER PCB-SD0000051790 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR AROCLOR 1248-1242 BLEND LOT NO. Initial as Completed 1. Empty No. storage tank. 2. Pump gallons of 1248 from No. storage tank to No. storage tank. 3. Pump gallons of 1242 from No. storage tank to No. storage tank. 4. Circulate tank for two hours and send sample to Lab. for Aroclor 1248-1242 Blend. Specific Gravity Specs.______ 1.430 - 1.440 (? 25C 5. If out of specs, make an adjustment. 6. If okay we will load tank car . 7. Take two one-half gallon samples from car or drum-out line. Label Aroclor 1248-1242 Blend, Lot No., and send to Lab. DSW 543093 WATER PCB-SD0000051791 TO: CHIEF OPERATORS Date: INSTEDCTIONS FOR SANTICIZER 794 LOT NO. Initial as Completed 1. Empty No. storage tank. 2. Pump gallons of 1260 from No. storage tank to No. storage tank. 3. Pump gallons of 1248 from No tank to No. storage tank. storage 4. Circulate tank for two hours and send sample to Laboratory for: Specs. 1.6375-1.6395 Specific Gravity 5. If out of specs., make an adjustment. 6. If okay we will load: Tank Car Remainder in Drums: 600 lbs. 7. Take two one-half gallon samples from car or drum-out line. Label Santlcizer 794, Lot No. , and send to Lab. DSW 543094 WATER PCB-SD0000051792 TO: CHIEF OPERATORS Date:____________ INSTRUCTIONS FOR AROCLOR 1254 - IPX TOLUENE LOT NO. (Send one-half gallon 125A and one-half gallon Toluene to Lab for Pilot Batch to determine spec.) Initial as Completed 1. Pump gallons of 125A from No. storage tank to small Pyranol mix tank. 2. Add pounds of Toluene to tank (full drums). Thief each drum to be sure it is clear and free of water. BE SURE that Toluene pump is connected to line to small tank. Check out line before starting pump. 3. Agitate for one hour. A. Take one-half gallon sample and send to Lab for 125A-10X Toluene. If out of spec, make adjustment. Spec. Specific Gravity ___________________________________________ 5. If okay, draw out in 60 lbs. and/or 600 lbs. Aroclor drums. 6. Stencil drums Aroclor 125A-1Q PCT Toluol, Lot No.. NOTE: Be .sure that the Pyranol Tank is empty before starting mix. . DSW 543095 WATER PCB-SD0000051793 TO: CHIEF OPERATORS Date:_______ INSTRUCTIONS FOR AROCLOR 1260 - 101 TOLUENE LOT NO. Initial as Completed 1. Pump gallons of 1260 from No. storage tank to small Pyranol mix tank. . 2. Add . pounds of Toluene to tank ( full drums). Thief each drum to be sure it is clear and free of water. BE SURE that Toluene pump is connected to line to small tank. Check out line before starting pump. 3. Agitate for one hour. 4. Take one-half gallon sample and send to Laboratory for 1260 - 10X Toluene. If out of spec, make adjustment. Specific Gravity Spec. 1.481-1.491 ________________________________ @ 40C 5. If okay, draw out in 60 lb. and/or 600 lb. Aroclor drums. 6. Stencil drums Aroclor 1260 - 10 PCT Toluol, Lot No. NOTE: Be sure that the Pyranol Tank is empty before star.ting mix. DSW 543096 WATER PCB-SD0000051794 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR AROCLOR 1262 - IPX TOLUENE LOT NO. Initial as Completed 1. Pump gallons of 1262 from No. storage tank to small Pyranol mix tank. 2. Add pounds of Toluene to tank ( full drums). Thief each drum to be sure it is clear and free of water. BE SURE that Toluene pump is connected to line to small tank. Check out line before starting pump. 3.. Agitate for one hour. 4. Take one-half gallon sample and send to Lab for 1262 10X Toluene. If out of spec, make adjustment. Specific Gravity @ 40C Spec. 1.504 - 1.514 5. If okay, draw out in 60 lb. and/or 600 lb. Aroclor drums. 6. Stencil drums Aroclor 1262 - 10 PCT Toluol, Lot No. NOTE: Be sure that the Pyranol Tank is empty before starting mix. DSW 543097 WATER PCB-SD0000051795 TO: CHIEF OPERATORS Date: INSTRUCTIONS FOR AROCLOR 1262 - 10% XYLENE LOT NO. (Send one-half gallon 1262 and one-half gallon Xylene to Lab for Pilot Batch to determine specification.) Initial as Completed 1. Pump gallons of 1262 from No. __________________ storage tank to small Pyranol mix tank. 2. Add pounds of Xylene to tank ( full drums). Thief each drum to be sure it is clear and free of water. BE SURE that Xylene pump is connected to line to small tank. Check out line before starting pump. 3. Agitate for one hour. 4. Take one-half gallon sample and send to Laboratory for 1262 - 10X Xylene. If out of spec, make adjustment. Spec. Specific Gravity 5. If okay draw out in 60 lb. and/or 600 lb. Aroclor drums. 6. Stencil drums Aroclor 1262 - 10 PCT Xylol, Lot No. . NOTE: Be sure that the Pyranol Tank is empty before starting mix. DSW 543098 WATER PCB-SD0000051796 | n2o< foOt-3a3 . Ti 0S4N 543099 WATER PCB-SD0000051797 OPERATING INSTRUCTIONS AROCLORS EMERGENCY PROCEDURE This is the plan for departmental action in the event a hazardous situation or injuries warrant emergency action either in the Aroclor Department or within the Anniston Plant. 1. Hazardous situations which might occur are: a. Operational accidents or difficulties, such as explosions, fires, release of toxic fumes, etc. b. Forces of nature - hurricanes, tornadoes, floods, lightning, etc. c. Deliberate damage - malicious actions, sabotage, direct enemy action. 2. The primary considerations in the event of a disaster are: a. The care of injured individuals and evacuation of personnel to safe areas. - b. Measures to prevent any, or further, property or equipment damage. c. Measures to provide accurate and thorough information so that other plant personnel and the community can be informed, if necessary. d. Prompt restoration of effected facilities and resumption of uninterrupted operations. 3. Responsibility: The areas of responsibility and overall department organization for disaster control are as follows: a. Chief Operator Responsible for continuing or closing down production facilities as conditions permit; for directing fire fighting and damage control activities in the department area; keep ing department supervision fully informed of conditions within the department. b. Operators Responsible for evacuation of all personnel from danger area; for directing and assisting in first aid and rescue missions; reporting to and keeping Chief Operator informed of conditions within his area of responsibility. NOTE: All actions of the Fire Brigade are coordinated with the Chief Operator. DSW 543100 WATER PCB-SD0000051798 Aroclor Department Emergency Procedure 2. 4. Details of Plan; a. In the event o an emergency, personnel must be accounted for. The first assembly area for the department is the open area south of the HB-40 Plant near the ladder rack: the second or alternate assembly area is east of the Aroclor-Biphenyl Building in the road near the shop entrance. It is very important to know where people are in an emergency or before action is taken to correct an emergency. If the alternate area has to be used, take whatevery safety equipment you can, from the department, to the assembly area. b. If assistance is needed, pertinent phone numbers of Plant personnel to be contacted are as follows: P. K. Ward H. L. Williams W. B. Papageorge V. R. Haupt M. J. Williams C. K. Eastman L. C. Fuhrmeister T. D. Tucker Dr. J. C. Francis 236-5218 236-3835 237-7974 237-7004 237-1952 236-3025 236-6773 237-3927 237-5612 (Home) Main Gate 236-2961 (308 or 317) c. In the event of a plant disaster, the Plant Manager's office is the control center. The alternate control center is the Guard Room at the Service Building. The medical center is the Plant Dispensary. The alternate medical center is the Service Building. d. If the emergency or disaster occurs before or after the day shift, or on a weekend, the department Chief Operator shall notify the guard on duty and the guard will be responsible for notifying plant supervision. e. Immediately upon discovering a fire, or a current or imminent disaster condition, turn in an alarm. DIAL 211 and tell where and what the emergency is. If the guard cannot be contacted, and the local Fire Department is needed, all them at 237-3541, giving them location, material burning, sire of area involved, etc. Then call the department supervision. NOTE: Chief Operator may designate this job to one of the Operators. DSW 543101 WATER PCB-SD0000051799 Aroclor Department Emergency Procedure 3. 5. Emergency Situations: The following equipment emergencies are possible at the Aroclor Department. Be prepared to take action in the event they should occur. Prepare yourself by knowing what to do - get help before hand on any part that is not understood. Emergency Action a. Fire Handling Biphenyl a. Turn in alarm - DIAL 211. b. Remove injured from fire areatake care of them. c. Proceed under Chief Operator to extinguish the fire: (1) Dry Powder extinguisher. (2) Fire truck, dry powder, and water. (3) Water. d. Pull power on all motors. e. Cut off gas to Aroclor and Biphenyl stills at main cut-off at northwest corner of blowing tank area. f. Shut down Department - Notify Chlorine Plant shutdown is necessary. b. Chlorine Release a. Obtain help and turn in alarm if necessary-notify Chief Operator. Tank Car-Chlorine Plant b. Obtain gas mask or Scott Air Pak. c. Shut off source of Chlorine. d. Notify Chlorine Plant if shutdown is necessary. e. Disconnect CI2 connection at car if necessary. f. If vaporiser is full of liquid chlorine, vent to the chlorine car, then shut off car. . g. Notify Department Supervision as soon as possible. DSW 543102 WATER PCB-SD0000051800 Aroclor Department Emergency Procedure Emergency c. BCl Release d. Fire or explosion at HB-40, Santowax, or Biphenyl Depts. e. Emergency in the Plant. f. Equipment failure creating hasard g. Injuries and Treatment -............................. 4 Action a. Obtain help and turn in alarm if necessary - Notify Chief Operator. b. Obtain gas mask or Scott Air Pak. c. Shut off source of BCl gas. d. Notify Chlorine Plant if shutdown is necessary. e. Notify Department Supervision as soon as possible. a. Turn in alarm, shut down Aroclor Department. Notify Chlorine Plant. Obtain gas mask, go to an assembly point, be prepared to assist in stopping the fire as directed by Chief Operator. a. Prepare to shut down on orders. a. Notify Chief Operator or Department Supervision. b. Take appropriate action. a. Obtain help. b. Prevent further injurier to person involved. c. Make comfortable. d. Know your first aid: (1) Mouth-to-mouth resuscitation. (2) Bow to use a resuscitator. (3) How to remove from electrical contact. (4) Action for a heat stroke. (5) Chest massage for heart failure. (6) Emergency action in case of burns. (7) Location of stretcher, blanket, oxygen. (8) Know equipment available from the dispensary. e. Contact Plant Physician as soon as possible if necessary. Make contact through Plant Guard or Dept. Supvr. . DSW 543103 WATER PCB-SD0000051801 EMERGENCY PROCEDURE COLD WATER TREATMENT OF BURNS APPENDIX A (Thermal & Chemical) Thermal Burn - The type of burn you would get by: 1. Direct exposure to flame. 2. Skin makes contact with hot surface. 3. Hot materials, such as molten Santowax, solidify when It touches the skin, thereby holding the heat in the skin. Chemical Burn - The type of burn you would get by: 1. Contact with Muriatic or Sulfuric Acid. 2. Contact with Potassium or Sodium Hydroxide. 3. Contact with any acid or strong alkali material. Treatment - Thermal Burns If possible, submerge burn area in container of cold water (50F.). The container may be a drum, water pail, wash basin - anything that will hold the water. Follow these steps: 1. Put water in container to desired depth. 2. Try to obtain a water temperature of 50F. by adding ice cubes. 3. Submerge bum area below the surface of the water. A. Transport injured person to the doctor, keeping burned surface submerged in water. If bum is in area that cannot be submerged in water, it is a good practice to take the cleanest cloth or toweling that you can obtain, soak it in cold water (wringing out excess water), and place on the burned area. This would be an area such as the back, shoulders, or stomach. UNDER NO CIR CUMSTANCES SHOULD A PERSON SUFFERING FROM THERMAL BURNS BE PLACED UNDER RUNNING HATER. There is a danger of the small droplets of water striking the burned area, causing pain to such an extent as to result in shock. DSW 543104 WATER PCB-SD0000051802 Cold Water Treatment of Burns 2. Treatment Chemical Burns 1. Place injured person under safety shower or some other method of washing with large amounts of water. 2. Remove contaminated clothing while under the shower. 3. If goggles are worn, keep in place until all the chemical has been washed from the body. General In our dispensary we have an ointment labeled Sulfathiasole. This material is used in the treatment of burns, both thermal and chemical. It allows an Injury to heal from the inside out, which is usually the situation with a burn injury. DSW 543105 WATER PCB-SD0000051803