318 CHAPTER 22 1960 Guide MOTIVE POWER Heating, ventilating, and air-conditioning fans are usually driven by electric motors, although other prime movers may be used. The small sizes of fans, and especially those operate ing in the higher speed range, are equipped with directconnected motors. For larger size fans, and those operating at lower speed, V-belt drives are generally used. In selecting the size of motor for operating a fan, it is advisable to select at least the standard size next larger thn the fan requirements. Direct-connected motors do not require so great a safety factor as belted units. Justification for liberal power provision exists only in systems where it is possible that larger volumes of air may be required at intervals, and made available by use of bypass dampers, thus greatly reducing the system resistance. If such a sys tem includes a fan with forward-curved blades, it would be necessary that the motor be sized for the maximum volume and duty. If such a system includes fans with backwardcurved blades, the volume peak would not make it necessary to provide additional motor power. In selecting fans for such Counter-Clockwise Top Hotuoatt) Clockwise Top Hocisootal Clockwise Bottom Horizontal tol-SW, SJ No 2 - SW, SI No3-SW,SI NoS-OW.Ol Bottom Horizontal Up Start No 4 - SW, SI No T - SW,SI No 7-O'M,01 NoS-SW.SI NoO-SW.Sl Fig. 6.... Arrangement of Fan Drives Arr. 1, SW, SI. For belt drive or direct connection- Wheel overturn*. Two bcsrinss ** bwe. Art. 1, SW, SL For belt drive or direct eoanectioc. Wheel overturn*, flfleringr sb bracket cupported by fan houam*. Arr. S, SW, SL For belt drive or direct eoanectiao. One bntin* am each ride ead copported by fan boorin*. Not reeommeaded in rises S7 in. diuMter wheel and mwfler. Ait. I, DW, DL Fer belt drive or direct oooneetaoo. One bcarin* on aach ride ead supported by fan houris*. Arr. <, SW, SL For direct drive. Wheel overfaun* on prime mover shaft. No beaiin*e an fen. Barn or equivalent for prime mover. Arr. 7, SW, SL For belt drive or direet connection. Arrangement No. J plus base for prime mover. Not recommended in risen 17 in. diametw and Arr. 7, DW, DL For belt drive or direct ocnaoctioa. Arrangement No. 8 phis base for prime mover. Arr. 8, SW, SL For belt drive or direet connection. Amngemest No. 1 plu* beat for prime mower. Air. B, SW, SL For belt drive. Arraagemeit No. 1 derigwd for mooatis* prime mover an side of bene. Top Angular Up Coento--C3ockwise Bottom Angular Down Bottom Angular Doom Note Direction of KofsHoo it determined from the drive ride for efther tinpie or double width or dngfe or doable inlet fans. (The Airing ride of a the actual location of the drieej For fan inverted fer ceding surpenrioa, directioe of rotation and dfcdtorge a determined when fan h resting on Soar. fig. 7.... Designation of Direction of Rotation and Discharge Fans a system, sound ratings should be given careful considera tion. Where a system is constant, and has no provision for volume change that would materially reduce the resistance, and when the resistance calculations are reasonably precise, there is no necessity for too liberal a motor allowance (even where fans with forward-curved blades are used) if the fan has been properly selected. Fig. 5 shows that the system re sistance varies as the square of the volume, and that the fan static pressure varies approximately inversely as the volume, thus greatly offsetting the trend toward both in crease in air delivery and motor load. Reference to Fig. 5 indicates that there is no justification for allowing large spare motor capacity. It is generally more economical to operate motors well loaded. Since the power consumption of fans varies as the cube of the speed, very little starting torque is required of the motor. Refer to Chapter 45 for characteristics of various types of motors. FAN SaEOlON The following information is required to select the proper type and size of fan: 1. Capacity in cubic feet per minute. 2. Static pressure or system resistance. 3. Air density if other bon standard. 4. Type of application or service. 5. Arrangement of system. 6. Prevailing sound level or use of space served. 7. Nature of load. 8. Type of motive power available. In order to facilitate the choice of apparatus, the various fan manufacturers supply fan tables or curves which usually show the following factors for each size of fan operating against a wide range of static pressures: (1) volume of air in cubic feet per minute (68 F, 50 percent relative humidity, 0.075 lb per cubic foot); (2) outlet velocity; (3) revolutions per minute; (4) brake horsepower; (5) tip or peripheral speed; and (6) static pressure. The most efficient operating point is usually shown by either boldface or italicized figures in the capacity tables. Often the service determines the type of fan. When opera tion occurs with little or no resistance, and particularly without a duct system, the propeller fan is indicated for con venience and low cost. When resistance is low the power Fig. 8 .... Motor Position, Belt or Chain Drive 319 Table 1.... Good Operating Velocities and Tip Speeds for Ventilating Fans Static Forward Carved Blade Foot Inch** of Water Outlet Velocity Fpm Tip Spaed Fpm Backward Tipped and Doable Curved BJode Outlet Velocity Fpm Tip Speed Fpm Tubtoail and Vaneaxial Font Wheel Velocity* Fpm X 800-1100 1300-1500 800-1100 2500-3100 1100-1500 X 80O-125C 1600-1850 800-125C 3000-3750 1250-1700 K 900-1450 1850-2150 900-1450 3400-4250 1400-1900 X 1000-1600 2050-2350 1000-1600 3800-4750 1500-2100 H 1100-175C 2250-2600 II00-I75C 4150-5200 1650-2350 X 1200-1900 2450-2850 1200-1900 4500-5600 1800-2500 1 1250-2000 2600-3000 1250-2000 4800-6000 1900-2700 IK 1400-2300 2900-3350 1400-2300 5350-6700 2150-3000 IK 1550-2500 3200-3700 1550-2500 5900-7400 2350-3300 IX 1700-2700 3400-3950 1700-2700 6350-7950 2500-3550 2 1800-2900 3700-4300 1800-2900 6800-8500 2700-3800 2K 1900-3050 3900-4500 1900-3050 7200-9000 2900-4050 2H 2000-3200 4100-4750 2000-3200 7600-9500 3100-4300 3 2200-3500 4500-5200 2200-3500 8300-10500 3300-4600 3K 2400-3800 4900-5650 2400-3800 9000-11500 4 2550-4050 5200-6000 2550-4050 9600-12000 4H 2700-4300 5500-6350 2700-4300 10000-12500 5 2850-4550 5800-6700 2850-4550 10500-13000 5K 6 7 8 9 10 2950-4750 6100-7050 2950-4750 11000-13750 3100-5000 6400-7400 3100-5000 12000-15000 3350-5400 6900-7950 3350-5400 12700-16000 3600-5750 7350-8500 3600-5750 13500-17000 3800-6100 7800-9000 3800-6100 14500-18000 4000-6400 8200-9450 4000-6400 15000-18500 required is low, and efficiency becomes of secondary im portance. When a duct system is involved the choice is usu ally made between a centrifugal fan and a tubeaxial or vaneaxial. At times the capacity-pressure-epeed relationship (specific speed)' dictates a choice. Usually, space, efficiency, sound, cost, and serviceability must all be considered.1* In general, centrifugal and aria! fans are comparable in effi ciency and sound, but the latter are lighter and require con siderably less space, especially if arranged for straightthrough operation. The comparison cannot be made on the cost of fans only, but the difference in cost of ductwork, mounting, and servicing must be included. A vaneaxial is more efficient and quieter than a tubeaxial, but is more ex pensive, and frequently requires more space. While requir ing less space than the centrifugal, the axial fiow fan is inherently less accessible for service. When high-temperature air or air containing corrosive elements is being conveyed, motors and bearings should be located outside of the air stream. This requirement may determine the type of fan to be used. Where the system resistance is indefinite or variable, the pressure, horsepower, and noise characteristics of centrifugal fans usually indicate their selection. Under such conditions, a steep and constantly rising pressure curve per mits less variation in air delivery when the resistance varies. Likewise, a fiat sound curve minimizes the change of moving into a region of increased noise. A fan having a high effi-