In -the follow-up to a finding at Dordrecht, we analyzed the No. 2 Wet finishing line every 30 minutes for 2 hrs for C-8 and % moisture. We received the following results. I am at a loss to explain why C-8 levels are varying
this much. Any ideas? If you know of someone else who's opinion would be of
importance here, please send this note on to that person.
Roger.
"'"*""'<? *"'''''^1aHB
EID936437
-0016563.txt
Roger,
Here are the results of the V-disk samples
VD-1 1564.75 PPM C8 VD-2 1302.68 PPM C8 VD-3 1173.65 PPM C8 VD-4 907.81 PPM C8 -
FEP 5100 - 30 minutes - 74.1% solids FEP 5100 - 60 minutes - 75-5% solids FEP 5100 - 90 minutes - 75.8 % solids
FEP 5100 - 120 minutes - 78.1 % solids
Time shown is time since starting feed of a new batch to the wet finishing system.
I'm not in the
if sure
the % solids change
C-8 concentration from sample
could cause such
to sample but it
a
massive could be
shift
a
factor.