Document 5kxRv1qog74dj6pLz0NQBpY1z

Tc1.v.''Chlo:~Jnibcnr;o-p-dlc?:in (TPO) Analysis )n Avtoclnvo Effluent X. CliC'S'.r.ndnrd Preparation Tliic analytical procedure van developed due to the need of sen sitivity in lev/ inn'on of concentration. Tho original analysis rue performed on n thermal conductivity detector, but no lower concoulrnlions of TDD would bo expected, this procedure proved to givo accurate and Quantitative ccasuronents at low levels. This analysis is based on a normalisation procedure. Internal standardisation can bo incorporated if needed. a. Into a 1-litcr volumetric flask is welshed 0,0000-0.1000 g. of 2,3,7,C-tetrachlorodibenzo-p-dicxin (TDD). Care should be takon in this procoduro so no not to allow any TDD to contact tlio skin or eyes, b. Brins the volume to 1-liter with bonzono. c. From this stock solution, several standards can be pre pared. Concentration of this solution will bo in tho range of .10 lag/al. or 100 ppm. It is suggested that a range of normaliza tion standards be prepared and used to obtain n normalization curvo. d. A 0,5 pi aliquot is used for tho analysis and gives full scale deflection at a moderate attenuation lovol. Keep tho container exposuro to air to a vory minimis to ovoid evaporation. Standards prepared in thin lab 7-3 aonths agostill give no ovidonco of change in response lovels. ' 2, TDD Analytical huno . Tho nutoclavo sanples aro diluted and transferred with water to civo an approximate weight ratio of 1:1, To the aquoous sasplo is then added an aliquot of benzene,-and tho sample is placed on a Kahn shnkor for 30 oinutes. If the two layors do not soparato on standing, tho sauple is centrifugod. a. A 0.5 fil sample is withdrawn from tho bonzono layer and injected: Into the instrument. Attenuations aro adjusted and dupli cate rune aro made. The poak heights of the TDD peaks are calcul ated and averaged.. b. Tho concentration of TDD on ppa is then calculated from tho following expression: M (Peak IT^t TDD) (Cone. Std u*/ul) (Totnl Voluno Extract) iL> (ppo) (Peak Hgt Normalization Std)(Sample \7t)(ag) whoro: attenuation adjustments aro equal for standard and sample. (Soo Figure 3 for an actual process sample). MONS 206363 o3 3. GLC Instrunent and Condition*; Instruoont; P-r I,;odcl 330 with dual flano dotcctors. Columns; 3* x 1/3" S.3. packed with L% (fluorooilicono oil) on C0-S0 nosh Chromanorb \i (n:JD3 treated). Operating Temperatures; coluisn oven - 215 C Isotkemal Injector - 325C Detector - 2G5C Carrier Gne (kTa) - 40 psi;j. inlet fjrcssure, 30 ral/nin exit flow. IIa (pro-purified) - CO pai. inlet* reference flnae - 15 psig. snnplo flaca - 15 pais. Air (breathing) - 5- psis* inlet, &GOO ml/rain flow. Sanplo Size; 0,c\ <0.C ul.). HONS 206364