` : M!PORTED AROCLOR CUSTOMER,INCIDENTS
Zitt;:.
Paso
Product
.r~
2/1980
Aroclor 1248
4...... X
Location /Firm
Result*
Brasili Indiana (UNIC)
Reported in letter from L. M. Spolyar, M. D., Director of Industrial Hygiene, Indiana State Board of Health. Gastro intestinal illness due to vapor inhalation plus possible liver damage (several . worker*).;-- .. . Advised protection against fumes at elevated temperatures. State Board of Health advised source was leaky galvanized pipes and corrective measures were taken at the plant. No further report of incidents or actions.
8/1964
feinshed Mason Co. Developed chest condition thought to jr Canada, Ltd; Vernon be from fume exposures. Reported
to Monsanto by S. Agostini Claims Representative, The Workmens Compensation Board, Toronto, Ontario. Aroclor bulletin and letter forwarded by Dr. Kelly. No record of further action.
HONS 044106
'fl'T* '^T*"^13633
6U+J-\ tKo - f Wo
Date 4/1966
Product
Location/Firm U. 5. Naval Station Kodiak, Alaska
ffe/L/?$*/*11*0' 6it-003/
* 1 (it/;*-
A^~&.
fl,/r
Re cults
Reaction to spot exposure to fumes -
eyes swollen, kidney soreness -
symptoms left within 36 hours. Response
by Dr. Kelly -.no further record of action
11/1968
Arodor 4465 '
Interchemical Corp. Reported by Monsanto salesmen (J. Sc hue
Presstite Div.
that two men over come by fumes.
St. Louis, Mo.
Caused plant strike. Source - damaged
drums, leaked fluid onto drum
heater. Forwarded new drums and
contacted by E. Wheeler and Dr. Kelly.
No further record of actions.
First quarter lnerteen
Westinghouse Co.
1969
54201 KA
Phoenix, Ariz.
(70% Aroclor 1254 )
(30% trichlorobenzene)
Exposure of truck driver to lnerteen fumes. Material being delivered to Westinghouse, Phoenix, Medical Department files on this subject attached.
January Therminol Fi
1969 u(cJ^ i(>(/>
\ Interchemical Corp. 3-6 maintenance men reported hand and
Toledo* Ohio
forearm rashes. Attributed to undue ^
Therminol leakages and frequent exposure
to hot fluid. Recommended new pump
seals and lower process temperatures for
reduced leakages.
MONS 044107
Also contacted by E. Wheeler. No further action reported.
HONS O4<tlQ0