Document 5kjBpQQEzxeeK6VE0pYbn9naJ

TECHNICAL REQUIREMENT FOR ASBESTOS - F T Iffl rH BVSOTTT.E * TR 31040 December 4, 1967 Revision #1 PLAINTIFFS EXHIBIT WCD-84 Composition Material Use Hydrous Magnesium Silicate Filler Property Test Method Form Visual Color Visual Specific Gravity RTV T-26B Moisture, % RTV T-l ' Magnetic Particles, number per 1G0 grams Note #1 Requirement Min. Max. Fibers White Gray 2.53 2.59 - 0.5 - 10.0 * Change Note 1: One hundred grams of material should be spread uniformly over a flat sheet of paper and stroked several times with a bar or horseshoe magnet* Paper "boots" may be used over the pole or poles of the magnet in order to facilitate removal of any adherent magnetic particles for counting. This should also be done over a clean . piece of white paper. Approved Suppliers Whittaker, dark, Daniels Rubberoid Co. Trade Name 1404 Fine Chrysotile 7TF Asbestos Floe. 7XF R. 6. Fisher Manager - Process Control