Document 5kLVmKNJn5aaQ23Z2RaXxEqQN
Air
Conditioning
,Unit Heaters
end Coolers
D. J. Murray Manufacturing Go.
Wausau, Wisconsin
Offices In Principal Cities MANUFACTURERS OF THE GRID UNIT
AND GRID BLAST COILS
Designed and tested to operate with steam or hot water systems--for steam pressures from 2 lbs to 250 lbs. Engineered along the same lines as the standard GRID Unit which had aluminum heating sections and has been on the market since 1929.
One piece construction "fin" heating sections of high test cast iron--no soldered, brazed, welded or expanded connections. Patented.
Overall dimensions for installation of Cast Iron GRID Unit Heater
Cl (CAST IRON) SERIES GRID UNIT HEATER DATA
Model No.
A
Dimensions B CD
Motor
Camelries
VoL Fan
5 Psi Steam 60 F
Approx. Shipp.
Pipe Size
Support Rod
E
Hp Rpm Cm
Btu/ Hr
Final Air TMPF
Lbs.
Supply Return Di&m.
Cl-1000 ny. I0>/2 l2'/4 \m 16 1/20 1750 675 30010 101
160 114
i'/.
CI-I2Q0 I4X I3H 12% 13% I9X 1/8 1750 IM2 54000 103
230 i%
1'/
CM500 17Vz I5H 12 16 23% 1/8 1750 1500 76500 107
300 i%
i'/.
CI-2000 22% 2m 12 21% 28% 1/6 1150 2600 143000 110 v 500 2
I'A
CI-2504 2T'h 25% 13 25K 35% 1/4 1150 3300 206000 117
675 2*
1%
Cl-2500 mi 25JS 13 25Jf 351/. 1/2 1150 4350 224000 107
700 2*
i'/.
CI-3000 32% 31 13 31
1/2 850' 6300 332000 108 1025 2'/i* i'/.
Cl-3000 32% 31 13 31 40% 1/2 1150 8000 380000 103 1075 2'/i" iy.
Vi Vi Vi Vi H H H
K
Furnished also with 2 in. top supply connection inlet.
NO ELECTROLYSIS TO CAUSE CORROSION
Low maintenance expense.
More air changes per hour.
Positive "directed " heat. No leaks--no breakdowns.
. Lower outlet temperature.
Larger air volume.
No soldered, brazed or expanded joints. . , Open design that keeps units clean.-
Send for complete catalog information Send for information on Blast coils and radiation.
990
4
Air Conditioning Industrial Heating Direct Fired Units
National Heater Co.
401 Essex Bldg., Minneapolis 2, Minn.
Nationai championL
STEEL S-P-A-C-E HEATERS
OIL--GAS-STOKER HAND FIRED UNITS
As shown in diagram these heaters are built as a complete unit consisting of heater, casing, firing equipment, multi ple blower assembly, motor, drive* induced draft blower and controls. NATIONAL HEATERS ^are con structed of welded copper bearing hot rolled one quarter inch boiler plate steel instead of the usual lighter ten guage plate. This provides positive assurance of life-long gas and smoke tight operation with ample provision for absorbing all strains resulting from expansion and contraction.
The body of the heat generator is long and narrow in design, allowing complete fuel consumption with prop erly spaced radiating fins to facilitate maximum heat transmission from this primary heating surface.
Casings are sturdy with insulated double metal walls to reduce wasteful radiation to a minimum. Panel type construction with rigid angle iron frames and structural iron reinforcement at both top and bottom assures a strong durable installation. Casings are designed for quick and con venient assembly.
ENGINEERING RATING CHART
HEATER NUMBER
B.T.U.
OUTPUT CAPACITY
2SPC.F.M.
MAX.
300 350 *00 550 600 650 700 750
640,000
660.000 1.215.000 2,000,000 2,500,000
3.000,000 3.500,000 4,000,000
6.200 11.000 16,150 32,000 45,000
52.000 56.000 60,000
CRATE AREA SQ.FT.
SQ.FT. HEATING SURFACE
VOLUME CU. FT. INSIDE HEATER
BLOWER
MAXIMUM
6.5 8.0 12.0 14.7 16.0 20.0 24.0 26.00
320 430 600 644 1421 1685 1610 1935
75 100 130' 175 - 315 375 450
4SO
16-TWtM I6TW1N 2ITWIN
ZrTRIPLE' 27TRIPLE 30"TRIPLE 30-TRIPLE 30**TRIPLE
BLOWER MOTOR
HP. MAX. RPM.
APPROXIMATE
TUBES
WEIGHT
NO. OIA.
LESS STOKER
3 1750 2 6" " 6*50
5 1750 ? 6"
14.4 20 .
7* 1750 10 4"
15.660 -
10 1750 12 4*
16.610
15 1750 16 4" 20,650
20 1750 16 4"
24,090
25 1750 18 4"
26.340
30 1750 20 4"
26,470
991