Report of Results: MVA9214 Examination of a SQUARE D
Electrical Box Exhibit C (Beach Case)
Prepared for: Lipsitz & Ponterio 135 Delaware Avenue, 5th Floor Buffalo, NY 14202-2415
Respectfully Submitted by: ^Jarries R. Millette, Ph.D. Executive Director
MVA Scientific Consultants 3300 Breckinridge Boulevard Suite 400 Duluth, GA 30096
10 May 2012
9214report-SqD1_ExhC_051012s
MVA SCIENTIFIC CONSULTANTS
SC-SDC-6001
Report of Results: MVA9214
Examination of a SQUARE D Electrical Box Exhibit C (Robert Beach Case)
Introduction
This report presents the results of an examination of a SQUARE D Class 6536 electrical control unit that was delivered to MVA Scientific Consultants from Sue McGregor of Lipsitz & Ponterio on 04 April 2012. The sample was assigned the MVA sample number X0478. MVA Scientific Consultants was asked to analyze the unit for asbestos content. Components of the unit were analyzed separately and assigned sample number modifiers as listed in Table 1. The analyses were done in our laboratory during the period of 09 April to 27 April 2012.
Methods
Each component was initially examined under an Olympus SZ-40 stereomicroscope at magnifications from 7X to 40X. A rasp was used to collect representative portions of the particulate from each component and these were mounted in Cargille refractive index liquids for analysis by polarized light microscopy (PLM) using an Olympus BH-2 polarized light microscope with a magnification range from 100X to 1,000X. The PLM analysis followed the analytical procedures recommended by the U.S. Environmental Protection Agency [1]. The PLM results for asbestos are given in terms of percent by volume.
A portion of the sample was also analyzed by Fourier transform infrared microspectrophotometry (micro-FTIR) utilizing a SensIR IlluminatIR infrared microspectrometer coupled to an Olympus BX51 microscope.
In order to determine whether or not asbestos fibers were readily releasable from the unit surface, a finger was applied to the surface of subsample X0478A and the particles transferred to an SEM stub for analysis by scanning electron microscopy (SEM). The SEM analysis was done using a JEOL JSM-6490LV coupled with a Thermo Scientific Noran System SIX x-ray energy dispersive spectrometer (EDS).
Results
Sample X0478 (SQUARE D Class 6536 electrical control unit labeled 'Exhibit C') contained three suspect pieces that were designated as X0478A, X0478B and X0478C (Figures 1 and 2). The results of the PLM analyses are summarized in Table 1.
Subsample X0478A contained 15-25% chrysotile asbestos by PLM (Figure 3). Asbestos fibers were protruding from the surface (Figure 4). According to the FTIR analysis, the resin binder in X0478A is consistent with a polyethylene (Figure 5). Asbestos fibers were released from the X0478A material and transferred onto a finger (Figure 6).
9214report-SqD1_ExhC_051012s
Page 2 of 9
Subsamples X0478A and X0478B appeared to be the same material. X0478B was not analyzed.
X0478C contained 10-20% chrysotile asbestos by PLM (Figure 7). Asbestos fibers were protruding from the surface (Figure 8).
References
1. U. S. Environmental Protection Agency, "Test Method EPA/600/R-93/116 -- Method for the Determination of Asbestos in Bulk Building Materials."
9214report-SqD1_ExhC_051012s
Page 3 of 9
Figure 1. Sample X0478 (SQUARE D electrical control unit) showing materials suspected of containing asbestos after the initial examination.
9214report-SqD1_ExhC_051012s
Page 5 of 9
Figure 2. Plate on Sample X0478 (SQUARE D electrical control unit).
Figure 3. PLM image of chrysotile from X0478A.
9214report-SqD1_ExhC_051012s
Page 6 of 9