Document 5k8nXEGDy57jBYw5p285eVkEN
Physical Chemistry Method 73-19 Job No. 1016022
CAS CHROMATOGRAPHIC DETERMINATION OF CHLORINATED BIPHENYL ISOMERS IN ARQCIOH PRODUCTS
PURPOSE OF ANALYSIS
Improved method for determining the chlorinated biphenyl isomer dis tribution in fractions from Aroclor distillation studies.
CHROMATOGRAPHIC CONDITIONS
Instrument: Varian Aerograph Series 1200
Type Detector: Flame Ionization
Column: 100'X 0.02* I.D. Poly 1-110 Support Coated Open Tubular (SCOT)
Column Temper*ture: 220*C
Detector Block Temperature: 300*C
Injection Port Temperature: 300*C
Sample Volume Injected: 0.001 ml Split 30/1
Plow Rates Helium: 6 ml/ain. Auxiliary Gas: 35 ml/min. Hydrogen: 40 ml/min. Air: 350 ml/min.
RETENTION TIMES (UNCORRECTED) OF COMPONENTS SEPARATED (CHROMATOGRAM ATTACHED)
Component Ho.
1 2 3 4 5 6 7
8 9 '*
10
11 12 13 14 15 16 17 18 19 20
21
Identity
Biphenyl o-Chlorobiphenyl
7,2'-Dichlorobiphenyl
m-Chlorobiphenyl p-Chlorobiphenyl
7,5-Diehlorobiphenyl
2,4- and 2,6-Dichlorobiphenyl
2,3 '-Dichlvobi phenyl 2#2 -Dichlorobiphenyl'
2,4*-Dichlorobiphenyl
2*5#2'-Trichlorobiphenyl tMuMArn Trichlorobiphenyl Unknown Trichlorobiphenyl 2,3,2*-Trichlorobiphenyl Unknown Trichlorobiphenyl 3,3*-Dichlorobiphenyl 3,4-Dichlorobiphenyl 3,4'-Dichlorobiphenyl Unknown Tetrachlorobiphenyl 4,4'-Dichlorobiphenyl
Unknown Trichlorobiphenyl
Retention Time (Minutes)
6.2 7.0 8.5 8.9 9.2 10.0 10.2 10.5 10.8
11.1 12.4 12.8 13.1 13.6 14.0 14.6 15.1 15.4 15.7 16.2 16.5
HONS 021716
Method 73-19 Page No. 2
Component No.
22 23 24 25
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
49 50 51 52
Identity
Unknown Trichlorobipheny1
2,5,4'-Trichlorobiphenyl 2,4,4'-Trichlorobiphenyl 3,4,2'-Trichlorobiphenyl 2,5,2',5'-Tetrachlorobiphenyl 2,3,4-Trichlorobiphonyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Pentachlorobipheny1 Unknown Pentachlorobiphenyl Unknown Tetrachlorobiphenyl
Unknown Pentachlorobiphenyl Unknown Tetrachlorobiphenyl 3,4,4'-Trichlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl 2,4,5,2',5'-Pentachlorobiphenyl Unknown Pentachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Tetrachlorobiphenyl Unknown Pentachlorobiphenyl Unknown Pentachlorobiphenyl Unknown Pentachlorobiphenyl Unknown Pentachlorobiphenyl Unknown Pentachlorobiphenyl
Retention Time (Minutes)
16.5 16.8 18.2 18,5 19.4 19,7 20.1 21.0 21.6 22.0 22.5 23.3 24.2 25.8 27.5 27.7 28.5 28.8 29.8 30.8 31.2 32.2 32.8 34.1 34.7 35.5 36.2 37.3 38.9 39.5 41.0
CALCULATION TECHNIQUE
Normalization With Area Correction Factors.
PRECISION
No determination of precision was made. The variability of a single GC analysis at the 95% confidence limits is usually 0.5 to It relative.
db
Monsanto Industrial Chemicals Co. Applied Sciences St. Louis, Mo.
7/74 - G. M. Gasser, E. M. Emery
HONS 021719
HONS 021720