Document 5emv6936owBkw1yZE5xxVnvN
1.
TNTRCPUCTLON
MCS 295 was developed as a fire resistant low tempera:urt neat transfer fluid. Production quantities of this fluid are requlred for
a tank car heating system at Vapor Corporation, Niles, Illinois.
Plve 15) drums of MCS 295 are scneduled for the first shipment and
the initial order Is estimated at 10,000 gallons.
SYNOPSIS OP PROCESS
NCS 295 Is prepared tiy thoroughly mixing trl-tetrachlorobenzene
with Aroclor 1242.
/t-4- u jhr*****
H sy^jC*** 1
BILL OP MATERIALS
TTCg Aasi*- " i
"
The process weights for 100 poundsof MCS 295 are as follows!
Aroclor 1242
8o pounds
Trl-tetrachlorobenzene 20 pounds
PROCESS IN DETAIL
.
To a clean, dry vessel, equipped with an agitator, charge 80 pounds of Aroclor 1242 and 20 pounds of tri-tetxmchlox-obenzsne.
Stir the blend for 50 minutes to Insure oomplete mixing. The final fluid la filtered through a sockor a string wound filter
Into drums. A one pound sample of theproduct should be submitted for analysis.
MATERIAL SPECIFICATIONS
Raw materials used In this formulation are commercially availsr.e products. Aroclor 1242 (Monsanto Code #81101) and trl-tetraehlorobenzene (Monsanto Code #58500) .must pass finished goods specifications.
i
The tentative specifications end methods of analyses fcr MCS 295
apa as follows:
;
Tentative Specifications
; Method
; WCBC
Anniston
Appearance: Clear, nearly whits oily | 10084 liquid
14.44-54
Viscosity, cs at 100`p 8.90 to 9*10
at 210 "P report
10086
14-4-52
Plre Point: none to boiling point
Sp.Or. 25/15.5C: 1.408 to 1.4ie
Pour' Point:
-15 max.
Acidity (mg KOH/gm) 0.05 max.
Moisture
75 ppm max.
. 10125
14-28-54
10114
14-49-54
1 Equal JFQ 100-A -
` 10087
14-42-54
10620
14-51-54
MOWS 036904
2,
TOXICITY AMD HAZARDS
The toxicity of NCS 295 is unknown at present and the formula tion should be handled with normal care. Repeated or continuous skin contact should be avoided ana Inhalation of vapors at elevated temperatures should be prevented. Tri-tet'rachlorobensene Is a flammable liquid and a moderate fire hazard. Fires resulting from this component can be extinguished with water (fog or spray) foam or carbon dioxide. Trl-tetraohlorobenzene Is Irritating to the respiratory system and eyes.
STREAM POLLUTION
Mo waste streams are discharged from this process.
4/24/64
J. D. Sullivan '
File copy Approved by Manager of Researoh
W. R. Rlohard
.. :
,
Date of Final Approval
:
<'
HONS 036905
PHYSICAL CONSTANTS DATA
me
NCS 295
IWSffilSTWRSCr
J. D.
wAm
fwmiU MtlituUi IWtU
Sullivan
tm---------4/24/84
A formulation
A Formulation . WUWfitA-BATi..
iIIIm Print M7M an
SOLI bum__ m.
miMbtaa___bu
CtwUUIdm MU
fSamiitiiottnt
aPirainittkit
r L...S5
*
/15.
S?fl_
:ll)t Ouritnr
1.412
Coritlctcnlri EwmUa SL*_
WtraVi!
VUMlttH
XiKuUu.
SmiSLAHUL IBUUKJl. minty a
JE
.9JK oi.
ElBkEittffiWsiL.
F-lnPimcWsCi
Mono to boiling ot.
HONS 036906
Tfritte OUm
NOTIi rtfii 4m i6W mt 6 nlmWmiM ftbnsmm Ckmdri Cmymy. Vm aMfilMaf iIhu If MMiHfy.