Document 5emv6936owBkw1yZE5xxVnvN

1. TNTRCPUCTLON MCS 295 was developed as a fire resistant low tempera:urt neat transfer fluid. Production quantities of this fluid are requlred for a tank car heating system at Vapor Corporation, Niles, Illinois. Plve 15) drums of MCS 295 are scneduled for the first shipment and the initial order Is estimated at 10,000 gallons. SYNOPSIS OP PROCESS NCS 295 Is prepared tiy thoroughly mixing trl-tetrachlorobenzene with Aroclor 1242. /t-4- u jhr***** H sy^jC*** 1 BILL OP MATERIALS TTCg Aasi*- " i " The process weights for 100 poundsof MCS 295 are as follows! Aroclor 1242 8o pounds Trl-tetrachlorobenzene 20 pounds PROCESS IN DETAIL . To a clean, dry vessel, equipped with an agitator, charge 80 pounds of Aroclor 1242 and 20 pounds of tri-tetxmchlox-obenzsne. Stir the blend for 50 minutes to Insure oomplete mixing. The final fluid la filtered through a sockor a string wound filter Into drums. A one pound sample of theproduct should be submitted for analysis. MATERIAL SPECIFICATIONS Raw materials used In this formulation are commercially availsr.e products. Aroclor 1242 (Monsanto Code #81101) and trl-tetraehlorobenzene (Monsanto Code #58500) .must pass finished goods specifications. i The tentative specifications end methods of analyses fcr MCS 295 apa as follows: ; Tentative Specifications ; Method ; WCBC Anniston Appearance: Clear, nearly whits oily | 10084 liquid 14.44-54 Viscosity, cs at 100`p 8.90 to 9*10 at 210 "P report 10086 14-4-52 Plre Point: none to boiling point Sp.Or. 25/15.5C: 1.408 to 1.4ie Pour' Point: -15 max. Acidity (mg KOH/gm) 0.05 max. Moisture 75 ppm max. . 10125 14-28-54 10114 14-49-54 1 Equal JFQ 100-A - ` 10087 14-42-54 10620 14-51-54 MOWS 036904 2, TOXICITY AMD HAZARDS The toxicity of NCS 295 is unknown at present and the formula tion should be handled with normal care. Repeated or continuous skin contact should be avoided ana Inhalation of vapors at elevated temperatures should be prevented. Tri-tet'rachlorobensene Is a flammable liquid and a moderate fire hazard. Fires resulting from this component can be extinguished with water (fog or spray) foam or carbon dioxide. Trl-tetraohlorobenzene Is Irritating to the respiratory system and eyes. STREAM POLLUTION Mo waste streams are discharged from this process. 4/24/64 J. D. Sullivan ' File copy Approved by Manager of Researoh W. R. Rlohard .. : , Date of Final Approval : <' HONS 036905 PHYSICAL CONSTANTS DATA me NCS 295 IWSffilSTWRSCr J. D. wAm fwmiU MtlituUi IWtU Sullivan tm---------4/24/84 A formulation A Formulation . WUWfitA-BATi.. iIIIm Print M7M an SOLI bum__ m. miMbtaa___bu CtwUUIdm MU fSamiitiiottnt aPirainittkit r L...S5 * /15. S?fl_ :ll)t Ouritnr 1.412 Coritlctcnlri EwmUa SL*_ WtraVi! VUMlttH XiKuUu. SmiSLAHUL IBUUKJl. minty a JE .9JK oi. ElBkEittffiWsiL. F-lnPimcWsCi Mono to boiling ot. HONS 036906 Tfritte OUm NOTIi rtfii 4m i6W mt 6 nlmWmiM ftbnsmm Ckmdri Cmymy. Vm aMfilMaf iIhu If MMiHfy.