Document 5d3NvGLB8qzDa58Q3NqooVj8

Mil 2 / II. CURRENT LEVELS (continued) : . D. 3.- Streams from 6 - 56 ppb neighboring Indus tries (Midwest Rubber, . American Zinc, Cerro, Mobil, Cooper.) . 4. Tank Car Wash Water from Rip Track 6,000 - 150,000 ppb ' 5. Plant Cooling Tower Water No detectable PCB's . 6. Plant City Water No detectable PCB's Hi. ' . CURRENT TECHNOLOGY - Removal from aqueous streams .. - A. Filtration - Can remove about 80-90$ of the PCB that are initially present. Have been about 3 ppb after filtration of material at 40 ppb level initially. ' B. Carbon Treatment - Anniston data indicate PCB reduction to 20 ppb by carbon adsorption of PCB and reduction to 5 ppb when filtration follows carbon treatment, . Muriatic acid after carbon treatment has residual * PCB content about 3*5 ppb. ' v Carbon treatment and filtration have permitted reduction in PCB content of tank car washes from about 50,000 ppb to 7 ppb. . C. Waste Treatment Pilot Plant . ' . Pilot data indicate reduction as follows. Average 1 i of two runs. Influent Lime treated Sand filtered Carbon treated 77 ppb PCB's 27 ppb 22 ppb 7 ppb At'this time there is .no research in progress to permit removal of PCB from aqueous streams to values below the carbon removal capability of 5 ppb. Carbon treatment of all streams are not contemplated at this time. . i 0S\N STLCOPCB4085310