Document 5bowQkVJ1V8NaEKonRpovBb1R

XATiCNAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANT5 COMPLIANCE STATUS information A EPA USE ONLY $~ C C. N A L T. N 5. Gamuts or operators of source of ha r.irdous 1; l.... r.. - lo the Xu i icn.i l E mis a ,on SUi ndurds J or liaz -- a rdous Air Poll.:..mis .ire required to submit the information contained tn Section I to the appropriate U.S. Environmental 6Protection Agency Ke^.jonn] Office before July , 1973. 5A listing ol regional offices is provided in 61.04. I II 1. 1 1 1 Mill 1 1 1 R 1 s 1 c 1 sc \3 1 LI I 1 1 I 1B AQCR 1 RP 111 CITY 2 8 LJ NDC 80 j | A. SOi.lCF. INTORMATION I I 1. Identification/Location - Indicate the name and address of each ii Mo j W| I C|H|E | Mil 1 cl A | L I |,| I U Is |a j | 1 a:3 COMPANY NAME AA8 i 1?1o I IB 1 ol XI I l|5 | ol | | | J 1 I I I I I A49 NUMBER 1 STREET NAME A 68 I p II I aIq I u| e Im 1e In Ie J 1 L|A 1 I 7 lO I 7l6 Ul 1 B33 STATE B34 Zl P CODE B38 ! i Ib k ,r vl T It. I t.If. 1 1 I I COUNTY 2. Contact - Indicate the name and telephone number of the owner or operator or other responsible official whom EPA may contact concerning this report. |G j | W j | D|A | l|G|R 1 E| | 1 | | 1 I I I I I * I 5|Q I 4|3 I 4| 8 16 15 I 9 11 J B3i NAME B S3 8 5* TELEPHONE 641 3. Source Description - Briefly state the nature of the source (e.g., "chloralxali Plant," or "Machine Shop"). lc i hIl |o 1 Rj- | a|l| kIaIl I il IpIlIaInItI I I I 1 I I 1 09 ' CA3 4. Alternative Mailing Address - Indicate an alternative mailing address if correspondence is to be directed to a location different than that specified above. U c G G C C L STREET NAME 'LU LL 075 ZIP CODE 79 5. Coro Ilance Status - The emissions from this source Z^7 can /___ / cannot meet tae emission limitations contained in the National Emission Standards on or before July 5, 1973. A t j j'j j ['L'lAsi-'ls b*--' M. M. Christensen SlGNATUHE O F OWNER, OPERATOR OR OTmER RESPONSiuL G I".: If the emissions from the source will exceed those limits set by the National Emission Standards for Hazardous Air Pollutants, the source will be in violation ar.d subject to Federal enforcement actions unless granted a waiver of compliance by the Administrator of the U.S. Environmental Protection Agency. The information needed for such waivers is listed in Section II of this form. PAGE 1 OF 4 PAGES s JN. ?;r: 3 should be completed ^ e uface.y :o-: eacr. point at emission cor eacn ha: cr.icci ool Intent. Pa USZ C sl'; i. Process Deserc~.o-ion - Provide a brief description of each process (e.g., "hydrogen end box" in a mercury chloralkali plant, "grinding machine" in a beryllium machine shop). Use additional sheets if necessary. In It Mp I ttIb U IgIm I I n In I p lo 1 cl i It I i In I gI Mill see att. G45 Pollutant Emitted - Indicate the type of hazardous pollutant emitted by the process. Indicate "A3" for asbestos, "BE" for beryllium, or "HG" for mercury, IaJ Jll C W G20 Amount of Pollutant named in Item 2 which Indicate the average weight of the hazardous material enters the process in pounds per month (based on the previous twelve months of operation). LL Co 4 _d _L Go 0 Control Devices a. Indicate the type of pollution control devices, if any, used to reduce the emissions from the process (e.g., venturi scrubber, baghouse, wet cyclone) and the estimated percent of the pollutant which the device removes from the process gas stream, L A. 1G. r It I t.It I F.l R 1 L 1 PRIMARY CONTROL. DEVICE TYPE J_L SECONDARY CONTROL DEVICE TYPE H51 H 53 UM.lsl PERCENT REMOVAL. EFFICIENCY MS41 | IIUHM55C PERCENT REMOVAL EFFICIENCY b. Asbestos Emission Control Devices Only i. If a baghouse is specified in Item 4a, give the following information: . The air flow permeability in cubic feet per minute per square foot of fabric area. Air flow permeability 20 cfm/f X?- . The pressure drop in inches water gauge across the filter at which the baghouse is operated. Operating pressure drop = inches w.g. . If the baghouse material contains synthetic fill yarn, check whether this material is /x / spun / 1 or not spun. Bag is 100*. spun polypropylene woven fabric. . If the baghouse utilizes a felted fabric, give the average thickness in inches and the density in ounces per square yard. Thickness = N/A inches Density = N/A oz/yd~ ii. If a wet collection device is specified in Item 4a, give the designed unit contacting energy in inches water gauge. . Unit contacting energy = inches w.g. /ST03537 U PAGE 2 OF A PAGES -------------------------------------------------------------------- ------r 77. AZA UiTS I E?a Die Only ol -st-i--:;.V:----i-`---s --j-n---.--v- -o---.--L---'----1--0-----o---p---e----r-a----t--e in comp,liance` witn tn e If j I f | j 1 | ( 1 j ` J --I--I--!--!--i 1 .... L. J..--. ,, I--- --.-.j ____t_____^___I ___x___________c;________________________ij .\.i;:or..U E.miss.on Stand..res for Hazardous Air Pollutants by July 5, 1973 may request ' : ; a waiver of compliance from ;he Administrator of the U.S. Environmental Protection Agency :U: the time ; period necessary to instail appropriaie control devices or make modifications to achieve compliance. 1 The Administrator mnv grant a waiver of compliance with the standard for a period not exceed: ng two | years from the effective date of the hazardous pollutant standards, if he finds that such period is ncces-- I sarv for the installation of controls and that steps will be taken during the period of the waiver to assure; that the health of persons wiil be protected from imminent endangerment. The reporting information provided in Section I must accompany this application. Applications i I should be sent to the appropriate EPA regional office. J 1. Processes Involved - Indicate the process or processes emitting hazardous pollutants to which emission controls are to be applied. Diaphragm--depositing mixing vat 2. Controls a. Describe the proposed type of control device to be added or modification to be made to the process to reduce the emissions of hazardous pollutants to an acceptable level.f Use addi ii tional sheets if necessary.) A fabric filter collection device will be installed to collect any asbestos fibers lost during dumping of asbestos in the mixing vat. b. Describe the measures that will be taken during the waiver period to assure that the health of persons will be protected from imminent endangerment. (Use additional sheets if necessary). See Attachment V 3. Increments of Progress - Specify xhe dates by which the following incre- I c meats of progress will be met. I C. II C . Date by which contracts for emission control systems or process modi- ^ fications will be awarded; or date by which orders will be issued for the purchase of the component parts to accomplish emission control or process modification. lot 6) la 18 ] IlIlT MONTH OAY YEAR 01 . Date of initiation of non-site construction or installation of emission control equipment or process change. j j Id Z.1 1 it 6 j 1 713 | MONTH OAY YEAR 02 . Date by which on-site construction or installation of emission control equipment or process modification is to be completed. L 54 L59 i ' PAGE 3 OF 4 PAGES -A. v i. 1 j- 3. "'"If 5 TON' TESTS. A waiver of emission resting may be grantee to ii i owners or operators of sources of beryllium or mercury pollutants if, ir. the judgment of the Administrator of the U.S. Environmental Protection Agency the emissions f.rom the source comply with the appropriate standard or if the owners or operators of the source have requested a waiver of compliance or have been granted a waiver of compliance. This application should accompany the reporting information provided in Section I. 1. Reason - State the reasons for requesting a waiver of emission testing. If the reason stated is that the emissions from the source is within the prescribed limits, documentation of this condition mus't be attached. N/A ST0353772 u U.S. GOVERNMENT printing OFFICE : 1973-726-697/503 3-1 PAGE 4 OF 4 PAGES B. 1. PROCESS DESCRIPTION Asbestos is dumped from sacks into a hooded vat to be mixed into a slurry. Air is drawn from the hood through a bag type filter to remove any asbestos particles released in the sack dumping operation. The amount of asbestos used in the operation is approximately 100,000 II. A. 2b. This mixing vat has been in operation for several years with a wet oycione scrubber on the outlet of the vat vent system. This has prevented visible emissions from the vat system and is presently in operation. The bag filter will replace the cyclone since the filter is a more positive collection device. The filter is on order and will be installed according to.the schedule below. ST0353773