Document 5bYpqa89NjDZxp1DxNRG4R5E4

SuOvC-ify o' $ ' j-.r me 25711 So^:M.fetd RoaC. $Ou\nl>e'0. M.cmj'n S075 Teifepnoi e 3M-3t2*3"!2D % August 13, 1970 Dr. Jon Konzen . Medical Director OWENS-CORNING .FIBERCIAS Toledo, Ohio 43601 CORPORATION Dear Dr. Konten: . Presented herewith are two copies of our report covering, the industrial hygiene survey conducted at the Bloomington plant several weeks ago. * In summary, we have found excessive exposures to asbestos fibers, marginally acceptable exposures to polyurethane dust and acceptable exposures to MDI vapor. From an over all viewpoint It is clear that the work environment in thisfacility muse be improved, and it is our recommendation that an entirely new process be installed including the appropriate environmental controls to maintain workroom concentrations of ssbestos and polyurethane dust at accept* able levels. The distinction between this facility and other facilities with which ve are familiar Is quite dra matic. Very truly yours, George D. Clayton President ' GDC:bh 02 401 0429 INDUSTRIAL. HYGIENE SURVEY OWENS-CORNINC FIBERClAS CORPORATION BLOOMINCTON, ILLINOIS PROBLEM "An industrial hygiene survey vi conducted et the Blooming ton, Illinois plent of Owen*-Corning Flbergiae Corporation to measure the exposures of vorkers In the Plant to asbestos fibers, MDI (Methylene bis (4-phenylIsocyanate)) vapor and polyurethane dust. .This survey vas conducted by Mr. George t>. Clayton of Clayton A Associates, Mr. Sam Thomas and Dr. Jon Konten of Cvens-Corolng Flberglas Corporation. INTRODUCTION Ovena-Corning Flberglas Corporation recently purchased a facility in Bloomington, Illlnola which is being used to produce insulation materials made from asbestos and polyure thane foam. On June 30, 1970 sampling was conducted in the batch mix, sanding and aide trim areas of tha asbestos board operation under near-normal production conditions. The sur vey continued on July 1 when MDI samples were taken near the forming operation for the polyurethane foam and along the , conveyor line as the foam vas being saved into smaller sec tions. The survey included dust samples taken near the aaving operations for polyurethane dust concsntrations. ASBESTOS INHALATION > Until recently the standard method of sampling asbestos in the workroom vas based on the number of particles per unit volume (millions of pertieles per cubic foot) determined by standard impingsr sampling and 100X llghtfield microscopy. For several years, tbs Threshold Limit Value (ACGIH) vas set at 5 mppcf* In 1969 the Threshold Limits Committee changed the TLV to a tentative value of 12 asbestos fibers per ml for fibers greater than 5 microns in length, as determined by phase contrast microscopy at A30X. In 1970 Che Committee reduced the TLV further to a tentative value of 5 fibers per milliliter on the aaae basis. The British Occupational Hy giene Society has adopted a standard for chryeotile of 2 fiber* per ml for fifty years of exposure, 4 fibers per mi for twentyfive years of exposure, or 10 fiber* per ml for ten year* of exposure. The** standards are, in the opinion of Che expert*, tha beat that can be drawn from existing data. Tbe#e data are 03 401 0430 /s 2 not ideal, and of course, the aeandarda are subject to review in the light of new evidence and Improved method* of measurement. Good Industrial hygiene practice suggests controlling ex posures below the maximum allowable level, rather than main tenance at the maximum. In this connection, it is appro priate to design current engineering controls for an expected airborne concentration of 2 fibers per ml in view of the trend downward in the acceptable exposure level and in accord ance with good engineering practice. ASBESTOS SAMPLING PROCEDURE *Tn line with the latest sampling development *, those speci fied by the Threshold Limit Value, air samples were collected on pre-velghed cellulose ester membrane filters by the use of Mine Safety Appliances personal samplers. Sampling races .were 1.8 - 2.0 liters per minute. Sampling periods varied between S and 17 minutes, depending upon the expected dust loading. At the conclusion of the sampling period,, the fil ter heads were removed and carried to a "clean" area where the filters vara carefully transferred to sealed containers * end transported back to the laboratory of Clayton & Associates; FIBER COUNTING PROCEDURE The method of counting asbestos fibers was that usmd by the U.S. Public Health Service for the enumeration of Asbestos dust on membrane filters* The description of this method by G. H Edvards and J. E. Lynch appeared in Ann. Occup. Hyg., ll, 1-6 (1968). After weighing, sections of the sample are mounted on stan dard microscope slides using a high viscosity solution of membrane filter material in a 1:1 mixture of diethyl oxalate and dimethyl phthalate to render the filter transparent. Since the mount la stable for 30 days, 35 mm color slides are taken as permanent records of representative areas of each filter. The asbestos fibers which lie on the surface of the filter are counted with phase contrast microscopy (as specified by the tentative Threshold Limit Value) using 10 x eye piece and a 40 x phase contrast objective. In mounting the sample, the transition of the duet-supporting substrate from translucent solid membrane filter cellulose **ter material to a transparent, optically homogeneous gel la very gentle. Clearing of the filter ia alow, requiring mbout 15 minutes, and at no time does a meniscus sweep 3 % acr oss the 'dust deposit. The filter slowly softens from be 1 ov caus ing no redistribution of th e fiber s Ten fields sele cted at random on the sample are counted and total f lb er s, fibers from 0 to 5n , fibers greater than 5m and fibers greater than I0u ere r eeorded. Any particle hav Ing an aspec t ratio of 3 or greate r is considered to be a f iber. - MDI INHALATION * The use of MDI (Methylene bia (4-phenylleocyanate)) haa bee ome vid espre in recent years in the production of poly ur e thane f oam. MDI is a liquid of re latively low volatlllt however, 1 t Is sufficiently volatile to produce vapor con* een tratlon s of MDI in the air in the range of one ppm which has been s hovn to be very irritating to many individuals. The ACG1H Thres hold Limit Value is 0. 02 ppm based on Industri al experlenc e vith the material. KB I SAMPLING PROCEDURE Samples were collected by the use of midget implnger# and battery driven pumps at a rate of 1.8 - 2.0 liters per minute for a minimum of ten minutes. The sampling solution vas IS * milliliters of a mixture of 35 ml of concentrated hydrochloric acid and 22 ml of glacial acetic acid diluted to 1 liter of vater. A second implnger containing 10 ml of IN caustic vas used in series vith the first implnger to absorb acid vapors. After sampling, the liquid solution vas transferred to a clean glass sample bottle for shipment back to the laboratory. The samples vere analyzed by using a colorimetric method at 550 millimicrons. The micrograms of MDI in the sample vere cal culated to ppm of KOI in the air samples. POLYURETHANE BUST SAMPLING PROCEDURE Samples vere coll ected on mllllpore membrane filters using the MSA personal samplers in mueh the same vay the asbestos samples vere coll acted, polyurethane dust is considered to be a nuisance due t for vhlch Che Threshold Limit Value is 10 milligrams per cu blc meter. 02 401 0432 -4 t RESULTS OF STUDY Xh* asbestos fiber staple* ire summarized In Table l. Poly* urethane dust samples are summarized in Table 2, and the MDI vapor samples are summarized in Table 3. Asbestos concentra tions are veil above the acceptable levels, and only 2 of 34 samples shoved less than 5 fibers per milliliter for fibers greater than 5 microns. The polyurethane dust samples gave mixed results, vith concentrations in excess of the TLV mea sured in about half the samples. The MDI samples vara all less than the Threshold Limit Value of 0.02 ppm, and appar ently this material presents no hazard in the plant at this time. . OBSERVATIONS AND RECOMMENDATIONS The atmospheric conditions in the vork environment of this plant are unbelievably bad. Obviously, at the time of con struction of this facility, no consideration vas given to protecting the health of the vork force. Such items as the baghouse discharging into the vorkroom are unacceptable when dealing vith such toxic materials as asbestos. The outdated equipment and methods of handling products prevent proper control under present conditions. Therefore, it is recom mended : 1. An entirely nev facility should be built for this operation; 2. Process engineers should be brought in to study the processes and material handling vith the idea of up-dating and improving the present process vith 'modern equipment. *rior to installation, hovever, the ventilation for tha procasses should be designed by persons vrho appreciate the consequences of over-exposure 'to toxic agents in the vork environment and vho art competent to prevent such exposures by appro prlate engineering control. These observations and recommendations apply both to the Unareo Board Line and the Polyurethane Line. (To attempt is aude at this time to make specific suggestions because the .plant is so ganerally unacceptable. In tha sMsntlae, conoidaeration must ba given to providing immediate personal res piratory protection for these vorkers until the plant has been remodeled. Va strongly.suggest that clinical studies bs 02 401 0433 5 conducted on these workers to determine the extent of Injury that may have already occurred because of the excessive expo sures these men have experienced over a period of time. It Is obvious that this plant has not been fully incorpor ated Into the Ovens-Cornlng Flberglas corporate structure, for It does not resemble other OCF plants with respect to environmental control. This report prepared by . AicJJL- Mutchler Engineering Services George D. Clayton President 02 401 0434 /3(.