Document 5bQZ8XpRka8vg6N3xwgeEk6rR
TO: S. S. MICHELS FROM: C. H. HORRELL
DATE: March 30, 1977
VCM MONITORING SUMMARY - MONTH OF FEBRUARY
Total number of VCM samples--------------------------------------------------------------------------------------Number of required personnel samples ---------------------------------------------------------------------
562 484
Dual tubes to check flasher tube for breakthrough-------------------------------------------
25
Percent exceeding the 20% criteria------------------------------------------------------------------------- ------------8
Percent to some degree less than 20%---------------------------------------------------------------------
16
Percent showing no breakthrough at all-----------------------------------------------------------------
76
Gas chromatograph check using a standard gas Allowable limit 1 PPM using a standard gas of approx. 5 PPM
Buildings
1
111 121 LPA Tank Farm
Number of tests Number within limit Number exceeding the limit
28 28 27 9 27 22 24 4
1 6 35
14 12
2
Gas chromatograph operating time:
Buildings
1
111 121 LPA Tank Farm
Percent of time in operation Percent down due to malfunction Percent down due to calibration
99.7% 0
0.3
96.7 3.0 0.3
98.0 1.8 0.2
83.7 ^16.3
100.0 0
Buildings
1
111 121 LPA Tank Farm
Number of leaks detected & tagged Number repaired & tag returned Number outstanding at end of month
38 34
4
55 50
5
Status of specific point leak testing
Building 1 Completed 111 80% Completed 115 40% Completed 121 60% Completed
92 9 2 94 5 0 --4 2
127 60% Completed
LPA
None
Tank
Farm None
Three highest Personnel Monitoring job classification by buildings:
Building 1 Job Class 1. HRC Helper No. of Samples 16 2. HRC/IIPC Operator 3. Recovery/Dryer Oper.
__ 7_ 12
Avg. VCM
3.80 3.29 1.16
Building 111 Job Class.
1. Day HelperNo. of Samples______________ 3^
2. Utility Operator
5
3. Recovery (Trans.) Oper.
4
Avg. VC-1
2.33 1.83 1.93
BFG66041
VCL MONITORING SUMMARY - MONTH OF FEBRUARY
-9 _
BuildinK 121 Job Class 1. Day Helper
No. of Samples
2. HRC Paste/Latex Oper.
3. Paste Che. Operator
2 5 5
A irrr * r?
VCM
4.70 3.69 3.66
LPA Job Class
1. Pipefitter
No. of Samples [10
2. Day Foreman (Tech.)
2
3. Field Operator
1
Avg. VCM 5.37 1.81 1.45
Off-Site ambient air sample results: Sample Location
Minimum Maximum
Averag e No. Samples
1. In front of Building 101 2. Resident 2103 So. 40th St. 3. Church 3705 Bells Lane 4. Resident 3613 Camp Ground Road 5. Wood Products Plant 1917 S. 40th St.
.00 .37 t it .* .00 .69** .00 .02
.00 .09 Overall Average
.105
.08 .003 .023 .070
6 -- 7 7 9 29
*Timer control failed **Could not find cause for this result
OVERALL AVERAGE OF OFF-SITE AMBIENT AIR SAMPLE RESULTS
BFG66042
cre .wa QO-z' 7 L5.
c.
a<
<<E3
I 2u
13 d
-t
n
2
1977
BFG66043
10 ii
j
12
.i 3 ;2
=1
j
5
'm
f
\
.-f.T
V,
{'
&
[UARI,,_
LARGE POLY AREA
1977 AREA MONITOR TREND
O O' o o o o o
O oo vo in m <s --<
[ BFG66048
T : V-----------------------------------
! 3HII JO IKSOaSJ
oo
' ::o L b
JANUARY
c to IV 2 0 FEBRUARY
& 10 1& 2 0 2 b
MARCH _________
ii IQ 1b a o 5 APRIL
I y IO lb -:o ib
I MAY_____________
i j!) 1u JUKE