Document 5bEoOaOy1VbE87VJr7yRopzGR
Heaters, Water
The Whitlock Coil Pipe Company
Manufacturers and Engineers
Baltimore, Md. Boston. Mass. Buffalo, N. Y. Charlotte, N. C. Chicago, HL Cincinnati, 0. Cleveland, 0.
Mta.Te,
Denver, Colo. Detroit, Mich. Grand Rapids, Mich. Houston, Tex. - Indianapolis. Ind. Knnftaa City, Mo.
HARTFORD, CONN.
Products
Memphis, Tenn. New Orleans, La. New York, N. Y.
Omaha, Neb. Philadelphia, Pa. Pittsburgh, Pa. Portland, Ore. Rochester, N. Y.
San Antonio, Tex. San Francisco, Calif. Seattle, Wash.
St. Louis, Mo. St. Paul, Minn.
Tacoma, Wash. Troy, New York Tulsa, Okla.
Darling Bros. Montreal, Manufacturers of Whitlock Heaters in Canada
See Telephone Directory for Local Address
Whitlock type " K" storage heaters are manufactured in both horizontal and vertical types. The table shows sues of the
horizontal heaters only. We will gladly furnish dimensions of horizontal heaters and vertical heaters upon request, lhat this type of heater is of particularly sturdy construction is evidenced by the increasing number of prominent engineers and architects who are specifying their use in aU types of buildings, including many of the largest and finest buildings constructed
Whitlock Type K Storage Heaters, Horizontal
SHELLS
To be used with Type K Heating Section Shell Prices include Cradle. Manhole 1 l',xl5*r
HEATING SECTIONS Capacity based on Heating from 40 to 180 with
Steam at 0 lbs. pressure. For other tempera tures and Steam Pressures see Bulletin No. 27
Gallons Diam
Number One
eter
Filling of Shell
Length of
Shell
Thick Thick Weight
ness
ness
of
of Shell of Head Shell
Number
Gallons lEIix
Maximum Size
Steam Pipe Indies
Smallest Shell
into which Section will Fit Inches
Weight
Entire Heating Section
Lbs.
65 18
60 Va
80 18
72 Va
3 118 24
60 Va
4 141 24
72 Va
5 164 24
84 Va
6 185 30
60 Va
220 72 Va
255 30
84 Va
9 290 30
96 \ Va
10 365 36
84
420 36
96 &
12 475 36 108 %
13 525 36 120 %
575 42 ' % %.
720 42
120
16 860 42 144
17 1000 42
168 %
950 1140 1310
48 48 48
120 144
V%i
168 Vt
1480 - 46
192 V*
1190
54
120 Vi
1430
54
144 Vi
1670
54
168 Vi
1900
54
1420
60
1710
60
28 2000 60
2300
60
746ft
72
192 Vi
120 %
144 %
168 'A
192 144
%%
31 2880 72
168 %
Vi 400 Vi 450 Vi 600
Vi . 700 Vi 800 ft 750 % 850
Vi 950 Vi 1050
Vz 1300
iVi 1450 1600
j 1800
Yt 1850
Y<At
2150 2500
V'z
2900 2850
3250 3700
<A 4100
<A 3250
<A 3700
Vz 4200
%Vi 4700 4300
% 4900 % 5600 % 6200 % 5700
% 6400
H0 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 Hll
H12 HI-3 HI4
HIS HI6
H17 H18 H19 H20 H21 H22 H23 H24 H25 H26 H27 H28 H29
H30
100 150 200 250 300 350 400 500 550 600 700 800 900
1000 1250 1500 1750 2000 2400
2800 3200 3600 4000 4400 4800 5400 6000 7000 8000 9000 10000
2 2 2 %
3V5 3'/z 3Vl IV?
5
13/z
5 5 5 6 6 6 8 8 8 8 10 10 10 12 12 . 12 12
18x 48 I8x 60 I8x 72 Ihx 48 18x 48 Itix 60
' I8x 60 I8x 72 18x 72 18x 84 24x 60 I8x- 96 18x108 18x1ZU
24x84 24x108 24x120 30x 96
30x120 30x132 36x 96 . 36x108 36x120 36x132
36x %
36x108 36x120 42x 96 42x % 42x108 42x108
75 80 90 175 185 190 200
210 215 220 300 260
270 285 370 425 450 570 620 670 860 920 950 1020 I2UU 1300
1380 1950 2000 2300
2460
~ DIRECTIONS FOR USE--Select the size storage you require and combine its designating number with the number
which designates thedcsired hourly ouiput. Assuming a required storage of 1000 gallons (No. 17 shell x 168) and a required
hourly output of 1750 gallons (No. H16 Heating unit) you would specify a Whitlock Type K, No. 171116.
510
The Whitlock Coil Pipe Company
Heaters, Water
WHITLOCK TYPE R INSTANTANEOUS HEATERS
. This type of heater is used extensively as an instantaneous heater in connection with a separate storage
tank, as a swimming pool heater, as a hot water convertor for use with a heating system as well as for various special conditions.
Standard sizes of the 2 and 4 pass heaters are shown in the table. Dimensions on multi-pass heater will be furnished on request.
Standard Sizes, Capacities, Dimensions and Weights
2 PASS. TEMP. RANGE. 40 F. to 80 F.
4 PASS TEMP. RANGE 40 F. to 120 F.
Size No.
Capacity
* Diam-
Gallons Over-all eter
per Length
of
Hour
Shdl
Size Water Connec tions
Size Steam Connec tions
Weight
Capacity Gallons Over-all
iE, Length
eter of
Shdl
Water Connec
Steam Connec
Weight
tions
tions
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 lb 17 18 wVi 19 I9l/z 20 21 22 23 24 25
150 350 650 1100 1600 1900 2550 3200 3800 5100 6350 7950 9550 12700 15900 19100 25600 31700 38200. 44400 50700 57100 .63450 79300 95100 126900 158400 191000 .
iiif
i9y 235/, 293/, 34>/, 241/, 30>/, 351/, 43>/, 551/, 45 52 67
5l7/, 59V, 59 71
61% 70% 78% 59% 643/, 76>/, 66 83 78 69
7 7 7 7 7 7
9/z 9Vz
9*/z 9'/z 9Vz >2 12 12 15 15 17 17 20 20 20 26 26 26 30 30 36 36
>/, ' i'/.
i'/. V/z
'vY/zf
22
2 2'/z
23
2vf 3
3'/z
.4
35
35
46
46
48
58
58
6 10
6 10
8 12
6 12
8 12
10 14
10 14
10 16
12 18
12 20
14 24
14 24
80 90 110 130 145 170 240 270 300 360 420 610 670 810 930 1040 1320 1510 1940 2100 2300 2870 3020 3500 4250 4780 6550 7060
Sizes 0 to 10 indusive, have Va* O. D. No. 18 B W. G. Copper Tubes.'
Remainder have r O. D. No. 17 B. W. G. Copper Tubes.
80 150 300 480 650 800 960 1350 1600 2100 2600 3300 4000 5300 6600 8000 10500 13300 16000 16500 21000 24000 26700 33300 40000 53300 66700 80000
i1i6'/$> 21$
26% 31%
24% 30% 353/4 4334 553/4 52 61 79 55% 65% 71 83 ' 72% 62% 92% 625/8 67% 82% 73 92 83 95
7 7 7 7 7 7
9Vi 9%
9% 9%
9% 12 1212 15 15 17 17 20 20 20 26 26 26 30 30 36 36
Va Va
1 1
1% 1% 1% 2 2 2
2% 2% 3 3
3% 4 5 5 5 5 6'
-6 6
6 8 8 10 10
1
1% 2 2
2/z 2% 3 3
3% 4 5 5 6 6 8 8 10 10 to 12 12 12 12 14 14 16
20 22
80 100 115 135 150 170 220
270 300 350 420 620 700 860 940 1070 1390 1580 2020 2230 2430 2600 3000 3480 4015 ' 4600 6100 6900
Sizes 0 to 10 indusive. have Va* O. D. No. 18 B. W. G. Copper Tubes.
Remainder have 1' O. D. No. 17 B. W. G. Copper Tubes.
Whitlock Heat Transfer Products include the following types of apparatus in addition to the Storage and Instantaneous Heaters shown above: Feed Water Heaters; Heat Exchangers; Fuel Oil Heaters; Superheaters; Condensers and Coolers for all kinds of liquids; Also pipe coils of any kind of pipe or tubing and Air and Ammonia Receivers.
_ Additional information and quotations covering any of this apparatus will be gladly furnished upon request.
511