Document 5bEN6wp9d4J0OgRLY7odpExk4

Boilers Utica Heater Company UTICA, New York 365 E. Illinois St. Chicago, III. 628 Union Building Cleveland, O. 1843 Grand Central Term'I New York, N. Y. Representatives In Principal Jobbing Centers Utica-Imperial SUPER-SMOKELESS Boilers Burn Soft Coal Smokelessly--Use Any Available Fuel Patented January 10, 1982. Utica-Imperial SUPER-SMOKELESS Boiler Cut-away View, Showing Primary and Secondary Combustion Chambers and Air Inlets SUPER-SMOKELESS BOILERS-- Are designed to operate smokelessly when burning soft coal. They utilize any avail able fuel, burning either hard coal, soft coal, lignite, coke, fuel oil or gas with ex ceptional efficiency and decided economy. ELIMINATION OF SMOKE-- Is attained by consuming the smoke and soot within the boiler. This complete combustion is due to the admission of highly heated air through water-jacketed inlets, in the baffle wall at the rear of the fire box. The admixture of oxygen at this point instantly converts the heavy gases into incandescent flames of unusual heat ing capacity. The smoke and soot are actually used as fuel and clean chimney and flues are maintained at all times. SUPER-SMOKELESS Boilers comply with the most rigid smoke ordinances and are recommended by foremost heating engineers and leading architects for impor tant buildings. CONSTRUCTION-- SUPER-SMOKELESS Boilers have a single grate and are of sectional cast iron construction. Cast iron is highly resistantto corrosion and preferable to steel where low pressure permits using it. The sectional construction permits easy handling in shipment as well as installation in com pleted buildings. The baffle wall is a specially designed water section of the boiler. It has a series of water-jacketed air inlets above the firebed and is covered on the side facing the fire by high-test plastic firebrick. OPERATION-- SUPER-SMOKELESS Boilers are ex tremely simple to operate. No special skill or high priced help is required. Long firing periods are the rule and little care or attention is required for successful, smoke less operation. 380 Utica Healer Company Boilers Capacities and Dimensions of Utica-Imperial SUPER-SMOKELESS Boilers Number - Steam Steam Ratings. Sq. Ft.. High Output High Efficiency Number Water Water Ratings. Sq. Ft. High Output High Efficiency Grate Area Sq. Ft. Length of Sections Inches Length of Sections and Smoke Box Inches S-245 S-246 S-247 S-248 S-249 S-335 S-336 S-337 S-338 S-339 S-3310 S-405 S-406 S-407 S-408 S-409 S-4010 S--4011 S--4012 S-4013 S--4014 S--4015 S--4016 S--4017 S--4018 S--4019 S-4020 S--4021 S-4022 S-4023 S-4024 1600 2075 2550 3025 3500 3000 3750 4500 5250 6000 6750 4125 5250 6375 7500 8625 9750 10875 12000 12700 13500 14250 15000 15750 16375 17000 17600 18150 18650 19100 19500 1200 1500 1800 2100 2400 2000 2500. 3000 3500 4000 4700 2750 3500 4250 5000 5750 6500 7250 8000 8750 9500 10250 11000 11750 12500 13250 14000 14750 15500 16250 17000 W-245 W-246 W-247 W-248 W-249 W-335 W-336 W-337 W-338 W-339 W-3310 W-405 W-406 W-407 W-408 W-409 W-4010 W-40II W-4012 W-4013 W-4014 W-4015 W-4016 W-4017 W-4018 W-4019 W-4020 W-4021 W-4022 W-4023 W-4024 2560 3320 4080 4840 5600 4800 6000 7200 8400 9600 10800 6600 8400 10200 12000 13800 15600 17400 19200 20320 21600 22800 24000 25200 26200 27200 28160 29040 29840 30560 31200 1920 2400 2880 3360 3840 3200 4000 4800 5600 6400 7520 4400 5600 6800 8000 9200 10400 11600 12800 14000 15200 16400 17600 18800 20000 21200 22400 23600 24800 26000 27200 5.00 6.25 7.50 8.75 10.00 7.32 9.10 10.87 12.65 14.42 . 16.20 9.68 12.03 14.38 16.73 19.08 21.43 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 23.77 37% 45% 533/4 62 70% 37% 45% 533/4 62 70% 78% 37% 45% 53% 62 70%. 78% 863/4 95 103% Hl% 1193/4 128 136% 144% 1523% 161 169% 177% 1853/4 194 48% 56% 63% 71% 79% 49% 57% 66 72% 80% 89 49% 57% 65% 74 82% 90% 97 105% 113% 121% 130 138% 146% 154% 163 171% 179% 187% 196 204% Capacities and Dimensions of Utica-Duplex SUPER-SMOKELESS Boilers Number Steam Steam Ratings. Sq. Ft. High Output High Efficiency Number Water Water Ratings, Sq Ft. High Output High Efficiency Grate Area Sq. Ft. Length of Sections Inches Length of Sections and Smoke Box Inches S-827 S-828 S-829 S-8210 S-8211 S--8212 S--8213 S-8214 S--8215 S-8216 S-8217 S-8218 12750 15000 17250 19500 21750 24000 25400 27000 28500 30000 31500 32750 8500 10000 11500 13000 14500 16000 17500 19000 20500 22000 23500 25000 W-827 W-828 W-829 W-8210 W-82II W-82I2 W-8213 W-8214 W-8215 W-8216 W-8217 W-8218 20400 24000 27600 31200 34800 38400 40640 43200 45600 48000 50400 52400 13600 16000 18400 20800 23200 25600 28000 30400 32800 35200 37600 40000 28.76 28.76 33.46 33.46 38.16 38.16 42.86 42.86 42.86 47.54 47.54 47.54 53% 62 70% 78% 86% 95 103% 111% 119% 128 136% 144% 70% 79 87% 95% 103% 112 120% 128% 136% 145 153% 161% Height of water line: 24 series. 45H inches; 33 series, 53 inches; 40 series, 57 inches; 82 series, 57 inches. Equipment Shipped with Boilers All Super-Smokeless Boilers are provided with equipment of the best type. Steam Boilers are equipped with Water Column with gauge glass and compression cocks; Retard Steam Gauge with Bourdon brass tube spring, Non-Glare Dial, syphon and cock; All-brass Pop Safety Valve, A. S. M. E. Standard; and Automatic All-metal Damper Regulator suitable for low pressure. Every boiler is furnished with a complete set of firing tools, consisting of shaker handle, hook, hoe, slice bar and flue brush with handle. Duplex Steam Boilers are equipped with Steam Header, Return Yoke, and Equalizer fitted with Hartford Connection which may be used or not, as desired. 381