Document 5b59NG5vgKd63Yxr5Nwq6zE9N

i! I :j \I I I5 m: i* Si i i \1 ;? I Ii i ' '$% Heating Systems Boilers Steel Cyclotherm Division National-U. S. Radiator Corporation Sales and Executive Offices Oswego, New York Factory'Distributors throughout the United States CYCLOTHEKM STEAM AND HOT WATER GENERATORS ... operate on Cyclonic Combustion prin ciple; Completely automatic with full safety controls. Oil, gas or interchange able gas and oil firing. Only four con nections required. The Cyclonic Combustion operating principle causes the fuel to be burned -while spiraling at high velocity around the inside wall: of the combustion chamber, forming virtually a tube of flame. This provides uniform and highly efficient heat'transfer over the entire furnace wall without hot spots. Com plete utilization of heat transfer areas provides quick heat as well as greater than 80 percent efficiency with the re duced maintenance of a two-pass design. 18 to 80 hp models are equipped with `on-off" control"; 100 to 500 hp models have modulated control. 80 hp units with modulating controls furnished at customers request. Automatic combus tion safeguard, low water and other safety controls are included. Size* from 18 to 500 hp Pressure Range Available in standard low pressure units or high pressures up to 200 psi. Hot water generators are also available in all sizes. Standard Burner Arrangements Fuel Cyclotherm Model No. Light Oil, 1 to 3 C-600 thru C-17,500 Gas, mfd., mixed and natural C-600 thru C-17,500 Comb. It. oil and gas C-600 thru C-17,500 Heavy Oil, 5, 6 and Bunker C C-2800 thru C-17,500 Comb. hy. oil and gas C-2800 thru C-17,500 STANDARD RATINGS AND DIMENSIONS Steam Units Hot Water Units Model Max. hp Output Btu No. Rating . Per Hour C-600 . C-1000 C-1400 C-1725 C-2100 C-2800 C-3500 C-4400 C-5200 C-7000 C-8700 C-10500 C-12000 C-13800 C-17500 18 ' < 30; 40- 50 * 60 80 100 125 150 200 250 300 350 400 500 603,000 ; 1,005,000 1,340,000 1,675,000 2,010,000 2,680,000 3,350,000 . 4,187,500 5,025,000 >. 6,700,000 8,375,000 10,050,000 11,725,000 13,400,000 16,750,000 Steam Per Hr (Lbs) Equiva lent Di rect Radi ation (Sq Ft) 620 1,035 1,380 1,725 2,070 . 2,760 3.450 4,315 5,175 - 6,900 8,625 10,350 12,075 13,800 17,250 2,513 4,188 5,583 6,980 8,375 11,167 13,959 17,448* 20,938 27,917 34,896 41,875 48,854 55,833 69,792 Gallons per Hr (100 Rise) 744 1,240 1,654 2;06S 2,481 3,308 4/135 5; 169 \ 6.203 8,270 10,338 12,405 14,473 16,540 20,675 Equiv. Direct Radiation 4,020 6,700 8,933 11,167 13,400 17,867 22,333 27,917 33,500 44,667 55,833 67,000 78.167 89,333 111,667 380 Overall Dimensions (Inches) Length Height Width 70H 80H 87M 84 124H 152 162*4 173H 197H 224}$ 251W 252 252 252 293*4 45H 55 57*4 57 H 64*4 66K 73H 84 H 91H 98*4 98H mi 102H 102H 102H 36 45 51 56 65 Heating Systems Boilers, Steel The Dewey-Shepard Boiler Go. Peru, Indiana STEEL FIRE TUBE BOILERS & HEATERS GAS & OIL FIRED VERTICAL FIRE TUBE UNITS capaciUes 95,000 to 1,000,000 Btu ASME :CODE CONSTRUCTED NATIONAL BOARD REGISTRATION All Dewey-Shepard boilers and water heaters (oil and gas fired) are built on the pat ented "Tube within a Tube" principle. All units are jacketed with fiber-glass insula- tion ready for instant hook-up. Oil Burners Underwriters Approved. Gas Burners A.G.A. Listed. Boilers Automatically Welded. Built-in Coils Optional. NET RATING Model Water, Sq Ft Steam, Sq Ft B 560 350 C 756 470 D 840 620 E 1120 700 F 1400 875 G 1540 965 H 1960 1230 I 2120 1330 J 2750 1720 K 3000 1895 L 4900 3200 M 5960 3730 Boiler ratings do not include allowance for Built-in Coils. * If piping and pick-up loss exceeds 20 percent of installed radiation, allow for such added loss. OIL and GAS BOILERS and WATER HEATERS Dewey-Shepard's patented "Tube within a Tube" principle gives you 80 percent or more heat absorption, resulting in pre-heating the incoming cold water before it comes in contact with the metal surfaces to which radiant heat is being applied. There is one square foot of heating surface for every gallon of water, transferring every possible unit of heat to the water, resulting in EFFICIENT, ECONOMICAL OPERATION . . . plus many other advantages for your customers, such as: LESS FUEL USED LOWER INSTALLATION COST* NO LIME--NO SCALE# 20 PERCENT LESS HEAT LOSS THROUGH THE STACK#NO EXPANSION, CONTRACTION OR CONDENSATION* CLEANEST HEAT POSSIBLE* SUFFI CIENT HOT WATER AT ALL TIMES ALSO MULTIPLE INSTALLATIONS 381