<7 'CYANAMID
Request For Capital Expenditures/Retirements
d v is o n o r c o mp a n y
Organic Chemicals Division
LOCATION
Chicago
JOS t it l e
Plant
J.O. CONTROL POINT
097
Install air supplied respirator system.
REPORTING CLASSIFICATION
DATE APPROVED
JOB ORDER NO.
D2
5/13/81
0C-5370
SUMMARY OF AMOUNT!
DESCRIPTION
LOCAL -URRENCY
0.5. COLL APS
ESTIMATED PROJECT COST
$30,962.
DISMANTLEMENT EXPENSE
TRANSFER EQUIPMENT
GROSS AMOUNT FOR APPROVAL LESS TRANSFER EQUIPMENT
$30,962.
LESS SALVAGE OR TRADE-IN ALLOWANCE NET CASH REQUIRED loor-3027>
l$3U r '9bT.
1 |
RETIREMENT DATA
COST DISMANTLEMENT LESS SALVAGE
AMOUN T
TOTAL - CHARGE RESERVE DESCRIPTION AND RCAS0N5 REQUIRED
E CONOMICS o$ called for in 1 leneral Procedure Memo #3
Attachment ( (Attach calculations)
ECONOMICS PERIOD
NET SALES ,N AT,,tP RO Ft T/SA VINOS) TOTAL INVESTMENT
7* ROI (o n t o t a l in v e s t .! INTERNAL RATE OF RETURN PAYOUT OF NEW FIXED CAPITAL!!
REV.#
1 2 t3 i:: 4 Jt 5
6
7
REVISION DET
OATE
4CUNT
CUM. AUTHORIZATION
Funds of
$30,962
are requested to purchase and install an air supplied respirator
system
0C-5370. 5/13/81 Page 2 of 5
Proposed Work and Cost
Funds of ---------------------------------------------------------------------------------------------- --$30,962 are requested to purchase and install an air supplied respirator system.
Present Situation
The OSHA lead standard adapted March, 1979, specifies a maximum allowable blood lead for employees exposed to lead dust. The allowable maximum lead blood was 80ug lead per 100 grams blood at the inception of the lead standard, and drops to 50ug in March of 1982. The sta dard further specifies that an employee whose lead blood 1 vel exceeds the standard must be removed from the^area wi h an airborne lead dust concentration above 50ug/m , and c .nnot be returned until the employee's lead blood level is 0 ug lower than the standard. The employee's lead blood le el must be below 40 ug for him to return to work if the standard is 60ug.
Due to the lack of feasable engineering technology, the airborne lead dust levels cannot be reduced to a level where respirator protection will not be required. Several corporate industrial hygiene studies have been made of airborne lead concentrations and potential employee exposure. The studies show we continue to have lead exposures above the OSHA limit of 200ug/m .
OSHA has accepted the company's petition for modification of its abatement program until February 15, 1983. One of the main purposes the company requested this extension was to install a air supplied respirator system.
It is the considered opinion of both division and plant management/! corporate industrial hygiene, that full time personal respirator protection will continue to be necessary to control employee lead dust exposure.
Blood lead levels have shown a steady decline from June, 1971, (date of American Cyanamid Company acquisition of the facility) when they averaged lOOug per lOOgm blood. Averages for the last five months in ug per 100 gm blood are:
12/80
1/81
2/81
3/81
4/81
Average % below 50
43 43 41 43 41 77 77 69 76 80
To enable the plant's employees to continue this downward trend of lead blood levels the resporator program must be stregthened.
N14633.01
CYWI 25-0007332
OC-5370 5/13/81 P ge 2 page 3 Qf 5
Justification
The OSHA regulations require, starting April 1, 1981, that any employee with a blood lead above 0.060ug/100gm must b : removed from his job. By March 1, 1983, those employees above 0.050ug/100gni must be removed from their jobs.
Air supplied respirators will enable the plant's employees meet this OSHA standard. This type of respirator has greater protection factor, and its fit is not as crit .cal as with a cartridge type of respirator.
Continued use of the half or full face cartridge .type
respirator is not a guarantee that we can maintain tb
blood lead levels-of all plant employees below the 50 level.
We have always been able to comply with the OSHA bloc . lead level standard but to assure we don't have excursion .bove the standard the proposed system must be installed.
Commercial Factors
This order supports a plant budget for lead stabilizers as
follows:
Marginal
Sales
Income
POS
(k$/lbs.)
lbs.
$%
$
Actual all stabilizers 1980
7,296
5,618 2,451 43.6 1,782
% 31.7
Budget all stabilizers 1981
6,400 . 5,207 2,337 44.9 1,512
29.0
First quarter stabilizers 1981
1,786
1,336
776 58.1
626
46.8
Details of Proposal
A Nash breathing air system will be installed. with a sub micron air intake filter. The compressor will be fitted with an over heating' alarm and a failure alarm. The breathing air will be piped throughout the plant to twenty-two (22) work stations. Twenty-two employees will be issued a new respirator, which will work on either the supplied air, or if disconnected from the system, a replaceable filter. Connection between the man and the piped air will be by a flexable hose.
This $ystem has been reviewed and approved by M. G. Kemplin of corporate industrial hygiene.
Production Factors
This proposal will not alter product quality or production rates.
CYWI 25-0007333
Page 3
00 5370 5/13/81 Page 4 of 5
Contingent Future Commitments
The Nash breathing air compressor uses 5 gpm of city 'ater to form the seal, wash the incomming air and humidify it for breathing. The additional cost of water to operate th .s system will be approximately $1,000 per year.
Additional cost for electricity will be approximately $5,900 per year.
Alternatives Considered
The use of self powered air helmet respirators are be ,ng tested for use where air line respirators are not pra :tical.
The use of fixed air cylinders to supply the breathir ? air for year around use is too expensive.
Risks
No operating risks are involved.
Concise Summary
Install an air supplied respirator system to help the plant meet the more stringent OSHA blood lead level regulations.
CYWX 25-0007334
s " *\
fdlNTtM
OOF- S027 REV. 7/82 u"<fc 7/82
DETAIL SHEET
s h eet n o .
JOB ORDER NO.
DATE
OC-5370 5/13/81 Page 5 of 5
COMPANY
ITEM OR
CODE NO.
American Cyanamid Company
DESCRIPTION
LOCATION
Chicago Plant
EQUIPMENT OR
MATERIALS
LABOR
Mar 'h 13, 1981
ENG. MECH
SVC
TOTAL
1 Breathing air compressor
7,177
2 Pump alarms
2,707
3 Piping and compressor installation 4,400
4 Electric
1,000
5 Respirators
3,277
6 Air prefilter
350
7 Schrader quick connecting system
.8 Air hoses
2,188 1,309
9 Freight
10 Illinois sales and use tax
100 1,554
24,062
4,500 2,000
200
6,700
200 200
7,377 2,707 8,900
3,000 3,227
350 2,388 1,309
100 1,554 30,962