Document 5OkeD8GkZvvOLBDZ7ER8pj3N

230 'CHAPTER 13 1948 Guide Aside from comfort and recuperative power of the patients, cooling is of great assistance in the treatment of fevers in the new-born and in post-operative cases, in enteric disorders, fevers;- heat stroke, heart failure, and in a variety of other ailments which often accompany summer heat waves. Problem of Odors The evacuation of battle casualties in aircraft and their subsequent hospitalization have stimulated efforts to minimize odors arising from draining wounds, old odorous casts, and gangrenous wounds. For air craft, chemical sprays and vapors, perfumes, oxidizing gases and venti lation methods are unsatisfactory. An ideal deodorant would purify the air by means of odor adsorption so that subsequently the air can be recirculated. Based upon the effectiveness of activated carbon' com mercially and industrially to adsorb odors, individual adsorption units' have been used successfully. In hospital wards the question of super iority of adsorption methods for elimination of odors over other methods remains to be answered. The present status of the problem is that the commercial aspect is highly controversial. REFERENCES *--Factors in the Control of the Spread of Acute Respiratory Infections with Reference to Streptococcal Illness and Acute Rheumatic Fever, by S. M. Wheeler and T. D. Jones {American Journal of the Medical Sciences, 209:58, 1945). 2--Laboratory and Field Studies of Glycols and Floor-Oiling in the Control of Air-Borne Bacteria, by A. P. Krueger et al (U. 5. Naval Medical Bulletin, 42:1288, 1944). a---Bacterial Content of Air in Army Barracks, by H. M. Lemon, H. Wise and M. Hamburger (War Medicine, 6:92, 1944). 4 A Study of the Nature and Control of Air-Borne Infection in Army Camps, by O. H. Robertson, M. Hamburger, C. G. Loosli, T. T. Puck, and H. M. Lemon (Journal of the American Medical Association, 126:993, 1944). *--Lethal Effects of Triethylene Glycol Vapor on Air Borne Bacteria and Influenza Virus, by O. H. Robertson et al (Science 97:142, 1943). 6_~The Present Status of Glycol Vapors in Air Sterilization, by M. Hamburger, Jr., O. H. Robertson, and T. T. Puck (American Journal of the Medical Sciences, 209:162, 1945). '--Summary of a 3-Year Study of the Clinical Applications of the Disinfection of Air by Glycol Vapors, by T. N. Harris and J. Stokes, Jr. (American Journal of the Medical Sciences, 209:152, 1945). *--Ultra-Violet Light Control of Air-Borne Infections in a Naval Training Center, by S. M. Wheeler, H. S. Ingraham, A. Hollaender, N. D. Lill. J. Gershon-Cohen, and E. W. Brown (American Journal of Public Health, 35:457, 1945). Recent Studies on Disinfection of Air in Military Establishments. (American Journal of Public .Health, Vol. 37, p. 189, Feb. 1947). *--The Present Status of the Control of Airborne Infections. (American Journal of Public Health, Vol. 37 p. 13, Jan. 1947). 11 ~A Comparative Study of the. Effect on Men of Continuous Versus Intermittent Exposure to a Tropical Environment, by N. Pace, M. B. Fisher, J. E. Birren, G. C. Pitts, W. A. White, Jr., W. V. Consolazio, and L. J. Pecora (Research Project X-205, Report No. 2, Naval Medical Research Institute, Bethesda, Md., May, 1945). 12*~Environmental and Physiologic Studies Aboard an Air-Cooled Hospital Ship En Route from Norfolk. Virginia to Cana) Zone (U. S. S. Tranquility (AH-14), 6-13 June 1945), by A. R. Behnke (Research Project X-205, Report No. 4, Naval Medical Research Institute, Bethesda, Md., September, 1945). is--Fundamentals of Anesthesia (American Medical Association Press, Chicago, 111., 2nd Edition, 1944, p. 204). 14--The Hazard of Fire and Explosion in Anesthesia, by B. A. Green (Anesthesiology 2:144, 1941). 15 Control of Physical Hazards of Anesthesia, by R. M. Tobell and A. W. Friend (Canadian Medical Association Journal 46:560, 1942). 1 A.S.H.V.E. Research Report No. 1111--Air Conditioning Requirements of an Operating Room and Recovery Ward, by F. C. Houghten and W. Leigh Cook, Jr. (A.S.H.V.E. Transactions, Vol. 45, 1939, p. 161). ,7_Unpublished Naval Studies by A. R. Behnke and O. Schneider (1940). Air Conditioning in the Prevention and Treatment of Disease 231 1 *--Disinfection of Air by Air Conditioning Processes, by C. P.. Yaglou and Ursula Wilson (American Association for the Advancement of Science, Publication No. 17, p. 129). ,9--The Control of Cross-Contamination by the Use of Mechanical Barriers, by J. A. Reyniere (Aero biology, American Association for the Advancement of Science, Symposium, 17:254, 1942). The Premature Infant: A Study of the Effect of Atmospheric Conditions on Growth and on Develop ment, by K. D. Biackfan, C. P, Yaglou and K. McKenzie (American Journal Diseases of Children, 46: 1175, 1933). 21-- Observations on the Control of Respiratory Contagion in the Cradle, by I. Rosenstern (Aerobiology, American Association for the Advancement of Science, Symposium, 17:242, 1942). 22--Physical Medicine, by F. H. Krusen (W. B. Saunders Co., Philadelphia and London, 1942). A.S.H.V.E. Research Report No. 1054--FeveT Therapy Induced by Conditioned Air, by F. C. Houghten, M. B. Ferderber and Carl Gutberlet (A.S.H.V.E. Transactions, Vol. 43, 1937, p. 131). A.S.H.V.E. Research Report No. 1161--Fever Therapy Locally Induced by Conditioned Air, by M. B. Ferderber, F. C. Houghten and Carl Gutberlet (A.S.H.V.E. Transactions, Vol. 40, 1940, p. 307). 24_Refrigeration for Anesthesia and Therapy, by L. W. Crossman and S. K. Safford (The Modem Hospital, 64:86, 1945). 'v --The Effect o0 Low Relative Humdity and Constant Temperature on Pollen Asthma, by B. Z. Rappaport. T. Nelson and W. H, Welker (Journal of Allergy, 6:111, 1935). 26--Hospital Air Conditioning, by C. P. Yaglou (The Environment and Its Effect Upon Man, Harvard School of Public Health, p. 244, 1939). Principles and Practices of Inhalations! Therapy, by A, L. Barach (J. B. Lippincott Co., Phila delphia, London, Montreal, 1944). 2 The Management of Pneumonia, by J. G. M. Bullowa, (Oxford University Press, p. 260, 1937).