Document 5LwgRKN2D9qNM9ax3y4LOddZJ
THE MOUNT SINAI MEDICAL CENTER
ONE GUSTAVE L. LEVY PLACE NEW YORK. N Y. 10029
o* I** or* W**MlWf* C0 tfwfOU
Mount Sinai School of Medicine `The Mount Sinai Hospital
April 11, 1979
Mr. Robert S. Magdelain, President Nilflsk of America, Inc. 201 King Manor Drive King of Prussia, Pennsylvania 19406
Environmental Seitncei Laboratory Cumminf, Basic 5cinc Buildtni 10 Eon 102 Street New York. New York 10029
Dear Mr. Magdelain:
This will report the results of air sampling tests conducted, In October 1978, to determine chrysotlle asbestos concentrations dur ing brake repair work.
Our major objective was to determine the efficiency of the Nilflsk
Asbestos System utilizing HEPA filters, particularly with regard to aubmlcroscople asbestos fibers. Studies conducted in our
Laboratory and elsewhere have demonstrated that free asbestos fibers present In brake drum dusts are predominantly shorter than 5um in
length. In particular, It was found that about 752 of the fibers In such dusts were less than 0.3um In length, as determined by
transmission electron microscopy. Thus, the optical microscopic technique used by OSHA for determining asbestos levels In workplaces (In which only fibers 5um or longer are counted) would overlook a
large number of asbestos fibers In air samples. That la, the total asbestos exposure in terms of fiber number, mass and surface area
would be significantly greater than the levels determined using the OSHA fiber-counting method.
Therefore, it was of considerable interest to us to have an oppor
tunity to test the efficiency of the Nilflsk Asbesto-Clene System. To do this personal air sampling was carried out on the exhaust of
a HEPA-filtered vacuum dust collector and, simultaneously, on a garage mechanic cleaning a brake drum with the Nilflsk brake en
capsulation cylinder. Three such tests were made. Background air samples, also using personal air. pumps, were taken.
For each of the teats, ^ sample of settled dust was taken from the brake drum. The dusts wire analyzed by x-ray diffraction in the atepscan mode to quantitatively determine asbestos contents, using a technique previously published. Asbestos was found in all three
samples, ranging from 2.52 to 4,52 by weight.
The membrane filters were analyzed by both transmission electron microscopy (X25,000) and by the standard OSHA fiber-counting
technique, employing phase contrast optical microscopy. The results are as follows:
SCF-ALLF-07590