Document 5LmpVMYwVx6gjrznGB4oJweM4
PLAINTIFF'S EXHIBIT
KRC-25
KOCH REFINING COMPANY
INDUSTRIAL HYGIENE EVALUATION ASBESTOS ABATEMENT PROJECT KOCH WEST PLANT
DOCK #9, PUMP HOUSE, SIXTH AND D STREET CORPUS CHRISTI, TEXAS
CONTRACTOR: BASIC INDUSTRIES OF SOUTH TEXAS NOVEMBER 2, 1995 THROUGH NOVEMBER 30, 1995
Report Prepared By
(M. Rigoberto Martinez
Health & Safety Management, Inc. 400 Mann, Suite 509
Corpus Christi, Texas 78401 (512) 882-3393
Approved By
Richard P. Griffin, CIH; CSP President
K 008358
Table of Contents
Subject Purpose Scope of Work Summary of Results Discussion of Results Conclusions Recommendations Observations Methodology
Appendix
Summary of Data
Supplement Laboratory Reports Sampling Data Sheets Daily Project Logs
Page 1 1 1 2 3 3 3 5
6
K 008359
Koch Refining Company
Koch West Plant Dock #9, Pump House, Sixth and D Street
Purpose
1. To document the work practices and Personal Protective Equipment (PPE) utilized by Basic Industries of South Texas (BIST) employees engaged in the handling of Asbestos Containing Material (ACM).
2. To determine representative exposure to airborne fiber concentrations by BIST employees engaged in abatement activities.
3. To determine the concentrations of airborne fibers which may have been released during the project.
4. To notify appropriate Koch Refining Company and BIST supervisory personnel of deviations from OSHA regulations and EPA guidelines pertaining to the removal of ACM.
Scope of Work
The removal of approximately 4,970 linear feet and approximately 844 square feet of ACM from Dock #9, Pump House, Sixth and D Street.
Summary of Results
1. Sixteen personal samples were collected on BIST personnel while involved in the abatement activities. Two of these samples were voided due to occluded filter medias. Twelve of these samples yielded calculated eight-hour Time Weighted Average (TWA) results ranging from <0.005 fibers per cubic centimeter (f/cc) to 0.076 f/cc, which were below the eight-hour Permissible Exposure Limit (PEL) of 0.1 f/cc established by OSHA. The remaining two samples yielded results above the OSHA eight-hour PEL of 0.1 f/cc. See "Discussion of Results".
2. Four area samples were collected upwind from the abatement during the course of the project. These samples yielded analytical results ranging from <0.007 f/cc to 0.012 f/cc, which were below the PEL of 0.1 f/cc established by OSHA.
3. Three area samples were collected in the equipment room of the decontamination trailer during the course of the project. These samples yielded analytical results
1
K008360
!' i*' t*-
ranging from 0.007 f/cc to 0.034 f/cc, which were below the PEL of 0.1 f/cc
established by OSHA.
4. Two area samples were collected at the entrance of the mini-containment. These samples yielded analytical results of 0.058 f/cc and 0.095 f/cc, which were below the PEL of 0.1 f/cc established by OSHA.
5. Three area samples were collected in the exhaust stream of the Pressure Differential Units (PDUs). These samples yielded analytical results ranging from <0.010 f/cc to 0.041 f/cc, which were below the PEL of 0.1 f/cc established by OSHA.
6. Eleven area samples were collected downwind from the abatement sites during the course of the project. These samples yielded analytical results ranging from <0.005 f/cc to 0.013 f/cc, which were below the PEL of 0.1 f/cc established by OSHA.
7. Two area samples were collected inside the mini-containments during the course of the project. These two samples yielded results of 0.009 f/cc and 0.075 f/cc, which were below the PEL of 0.1 f/cc established by OSHA.
8. One area sample was collected inside the control room, out of the regulated area, during removal of ACM. This sample yielded an analytical result of <0.006 f/cc, which was below the PEL of 0.1 f/cc established by OSHA.
9. Nine clearance samples were collected inside the containments after gross removal of ACM was completed. Eight of these samples yielded results below the EPA standard for clean air of 0.01 f/cc. The remaining sample yielded a result of 0.014 f/cc. See "Discussion of Results."
10. Twenty-one blank samples were submitted for correction of sample analysis during the course of the project.
Discussion of Results
1. Two personal samples, #12234 and #12237, yielded TWA results above the OSHA PEL of 0.1 f 'cc; however, it is felt that the employees were not exposed to fiber concentrations above the PEL due to the type of respirator protection utilized while in the containments. 3M Powered Air Purifying Respirators (PAPRs) with dual High Efficiency Particulate Air (HEPA) filters, NIOSH approval #TC-23C-1479, were utilized. The respirators offered a protection factor of 100 x PEL or lOO x 0.1 f/cc = 10 f/cc.
2. Clearance sample #12258 collected on November 16, 1995, yielded an analytical result of 0.014 f/cc, which was above the EPA standard for clean air of 0.01 f/cc.
2
K 008361
The containment was wet-wiped and locked down again, and a second clearance sample, #122265, was collected on November 20, 1995, inside the containment. This sample yielded a result of 0.004 f/cc, which was below the EPA standard for clean air of 0.01 f/cc.
Conclusions
1. OSHA regulations and EPA guidelines pertaining to the removal of ACM were followed throughout the project.
2. Based on the sample results and the Personal Protective Equipment (PPE) utilized during abatement, it is felt that employees engaged in the asbestos removal project were not exposed to airborne fiber concentrations above the OSHA PEL of 0.1 f/cc.
3. Based on analytical results, it is felt that employees outside the regulated areas and not involved in the abatement activities were not exposed to airborne fiber concentrations above the OSHA PEL of 0.1 f/cc.
Recommendations
1. Notify the monitored employees with the results of their personal breathing zone samples.
2. Continue to follow all applicable OSHA regulations and EPA guidelines pertaining to the removal and disposal of ACM.
3. Continue to monitor all asbestos abatement projects or projects where ACM may be disturbed.
Observations
1. The area of abatement was demarcated with barricade tape bearing the message "Danger Asbestos". The demarcated area was regulated by the posting of OSHA required "Danger Asbestos" signs.
2. Employees engaged in abatement activities utilized the following Personal Protective Equipment (PPE): two pairs of disposable coveralls with attached hoods and booties, hard hats, cotton gloves, steel-toed rubber boots, safety harnesses, 3M half-face respirators with dual High Efficiency Particulate Ar (HEPA) filters (NIOSH approval #TC-21C-488), or 3M full-face PAPRs with dual HEPA filters (NIOSH approval #TC-23C-1479).
3
K 008362
3. The workers utilized Nomex coveralls on some removal sites. The suits were washed and dried after each use. The washer and dryer were set up in a regulated building. PPE was utilized in the building. The dryer was exhausted through a Pressure Differential Unit (PDU), which filtered the air through pre filters and HEPA filters.
4. The workers achieved decontamination before breaks and at the end of the shifts by utilizing BIST's portable decontamination trailer.
5. The abatement workers were transported to the decontamination trailers in the back of BIST's pickup truck before breaks and at the end of the shifts. The truck beds were lined with 6-mil polyethylene during transport. During transport to the decontamination trailers, the workers wore two disposable suits of which the outer suit was taken off and replaced with another suit.
6. The majority of the removal was achieved utilizing mini-containments. Glovebagging was also performed to achieve gross removal.
7. The workers utilized the half-face respirators during construction and demolition of the containments, and the PAPRs during removal inside the containments.
8. A mixture of water and "Certane Raincoat" was utilized during the removal of ACM inside the containment. The surfactant was applied with manually pumped airless sprayers.
9. Sample results were supplied and posted on the next working day after samples
were collected.
"
4 K 008363
Methodology
Personal and area samples were collected utilizing SKC low-flow sampling pumps set to draw air at approximately two and one-quarter liters per minute. These pumps were calibrated both prior to and following the sampling period utilizing a primary standard. The calibrator was connected to the pumps following the same sequence of equipment which was used in the actual sampling procedures. Both the beginning and ending flow rates were obtained by averaging the results of three separate calibrations. Each of these calibrations were within 1% of each other. Furthermore, the average of the beginning and ending calibrations were within 10% of each other.
The personal samples were collected in the breathing zones of the individuals. The area samples were collected at a height of approximately five to six feet from floor level in order to determine the potential exposure to employees working in the area. The samples were collected on 25mm filters of 0.8 micrometer porosity mounted in an open-face holder. The fiber content of each filter sample was analyzed following NIOSH procedure 7400 by a laboratory participating in the NIOSH PAT program for asbestos.
Wedges from each filter were examined at 400 power using phase contrast microscopy. Fibers equal to or longer than five microns with a length-to-width ratio of 3:1 were counted as asbestos.
Clearance
The post abatement samples were collected utilizing the Thomas high-volume sampling pump set to draw air at approximately ten liters per minute. These pumps were calibrated both prior to and following the sampling period. The calibrator was connected to the pump following the same sequence of equipment which was used in the actual sampling procedures. The sample volumes were selected so that a detectable limit of 0.01 f/cc or less could be obtained. Both the beginning and ending flow rates were obtained by averaging the results of three separate calibrations. Each of these calibrations were within 1% of each other. Furthermore, the average of the beginning and ending calibrations were within 10% of each other.
5 K 008364
Personal HSM95 Sample # 12221 12279 12222
12224 12240 12231
12234
12237
12241
12244 12254 12245
12262
12282
Koch Refining Company Koch West Plant
Dock #9, Pump House, Sixth and D Street
Summary of Data
Date 11/02/95 11/22/95 11/02/95
11/03/95 11/09/95 11/06/95
11/07/95
11/08/95
11/09/95
11/10/95 11/14/95 11/10/95
11/18/95
11/27/95
Name/SS#
Michael Perez 450-29-9027
Edward Honojosa 457-35-0230
Roy Guerrero 458-63-1200
Ronald Guerrero 458-63-7756
Daniel Martinez 449-33-9274
John Alvarez 451-59-4376
Luis M. Garcia 450-27-5002
Andrew Cannon 463-82-1712
Steve Marroquin 461-33-5868
Raul Yanez 459-29-9027
Stacey Thompson 114-66-2512
6
Airborne fibers f/cc 0.013 0.305 0.007
0.211 <0.006
Void
2.649
1.216
0.198
0.038 0.024 0.008
Void
0.023
8-hr TWA 0.007 0.037 0.006
0.046 <0.005
0.579
0.393
0.0076
0.010 0.005 0.006
0.009
K 008366
HIWH1 <mm,j
(-' V'./uV
. '/
Summary of Data
Personal (continued)
HSM95 Sample # 12292
12293
Date 11/30/95
11/30/95
Name/SS#
Margarito Garcia 466-37-7175
John Yanez 459-29-9172
Airborne fibers iZsc 0.010
<0.006
8-hr TVVA 0.008
<0.005
Area (Upwind) (See sampling data sheets for area locations.)
HSM95 Sample #
Date
Airborne fibers f/cc
12219
11/01/95
0.005
12275 12286
11/21/95 11/28/95
<0.007 0.012
12289
11/29/95
<0.011
Area (Downwindl
HSM95 Sample #
12218
Date 11/01/95
12229 12230 12235 12238 12249 12252
11/06/95 11/06/95 ' 11/07/95 11/08/95 11/13/95 11/14/95
Airborne fibers f/cc
<0.006 <0.005 <0.005 <0.006
0.010 <0.010 <0.016
7
K008367
mm
,.V
- ;J ' /i-: Summary of Data
Area (Downwind) (continued)
HSM95 Sample #
12256 12274 12287 12290
Date 11/16/95 11/21/95 11/28/95 11/29/95
Airborne fibers f/cc
<0.010 <0.007
0.013 <0.011
Area (Equipment Room)
HSM95 Sample #
Date
12261
11/18/95
12267
11/20/95
12268
11/20/95
Area (Inside Mini-Containments)
HSM95 Sample #
Date
12225
11/03/95
12251
11/14/95 _
Airborne fibers f/cc 0.007 0.025 0.034
Airborne fibers f/cc 0.009 0.075
Area (Inside Control Room)
HSM95 Sample #
Date
12260
11/18/95
Airborne fibers f/cc
<0.006
8 K 008368
Area (Exhaust of PDU)
HSM95 Sample #
Date
12242
11/09/95
12248
11/13/95
12257
11/16/95
Summary of Data
Airborne fibers f/cc 0.041
<0.010 <0.010
Area (Entrance to Containment)
HSM95 Sample #
Date
12278
11/22/95 -
12281B
11/27/95
Airborne fibers f/cc
0.095
0.058
Clearance (Inside Containment!
HSM95 SamDle #
Date
12227
11/03/95
12232
11/06/95
12246
11/10/95
12253
11/14/95
12258
11/16/95
12263
11/18/95
12265
11/20/95
12281A
11/22/95
12284
11/28/95
Airborne fibers f/cc 0.003 0.007 0.006
<0.004 0.014
<0.004 <0.004 <0.004
0.006
9
K 008369
Blanks HSM95 Sample # 12220 12223 12226 12228 12233 12236 12239 12243 12247 12250 12255 12259 12264 12266 12269 12276 12280 12283 12288
Summary of Data
Date 11/01/95 11/02/95 11/03/95 11/03/95 11/06/95 11/07/95 11/08/95 11/09/95 11/10/95 11/12/95 11/14/95 11/16/95 11/18/95 11/20/95 11/20/95 11/21/95 11/22/95 11/27/95 11/28/95
fibers/100 fields 2.0 1.0 0.0 7.0 4.0 0.0 5.0 4.0 2.5 2.0 0.0 1.0 2.0 2.0 0.0 1.0 0.0 1.0 3.0
10
K 008370
Blanks (continued)
HSM95 Sample if
Date
12291
11/29/95
12294
11/30/95
Summary of Data
fibers/100 fields 2.0 1.0
11 K008371
.............. "`IIIIIM lilliillllll
Laboratory 2(eports
K 008372
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, QH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1369 11/13/95 3 Seth Beidron 11/15/95 Rudy Orta
Lab# CA95.1369 CA95.1370 CA95.1371
Sample ID# 12248HSM95 12249HSM95 12250HSM95
Results of Analysis
Fibers Counted
7.5
5.0
2.0
Fields Counted
100
100
100
Air Volume (liters')
477.0
499.5
__
Fiber Concentration (flbers/cc)*
<0.010
<0.010
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
---
Laboratory Supervisor K 008373
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CEH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1378 11/14/95 5
Seth Beidron 11/15/95 Rudy Orta
Lab# CA95.1378 CA95.1379 CA95.1380 CA95.1381 CA95.1382
Sample ID# 12251HSM95 12252HSM95 12253HSM95 12254HSM95 12255HSM95
Results of Analysis
Fibers Counted
50.5 8.0 4.0
10.0 0.0
Fields Counted
100 100 100
100 100
Air Volume (liters')
335.25 321.75 1224.0
207.0 ...
Fiber Concentration (fibers/cc)*
0.075 <0.016 <0.004
0.024 BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
Laboratory Supervisor K 008374
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, C3H, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1344 11/10/95 4 Seth Beidron 11/14/95 Rudy Orta
Lab# CA95.1344 CA95.1345 CA95.1346 CA95.1347
Sample ED# 12244HSM95 12245HSM95 12246HSM95 12247HSM95
Results of Analysis
Fibers Counted
23.0
15.0 9.5 2.5
Fields Counted
100
100 100 100
Air Volume (liters')
273.28
745.8
821.74 ___
Fiber Concentration (fibers/cc)*
0.038 0.008 <0.006 BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
briy Mills boratory Supervisor
K 008375
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, QH, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1356 11/08/95 3 Seth Beidron 11/13/95 David Ramirez
Lab # CA95.1356 CA95.1357 CA95.1358
Sample ID# 12237HSM95 12238HSM95 12239HSM95
Results of Analysis
Fibers Counted
169.5
19.5
0.5
Fields Counted
20
100
100
Air Volume (liters')
348.75
911.25
Fiber Concentration (fibers/cc)*
1.216
0.010
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Ruie A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
//Tony Mills Laboratory Supervisor
K 008376
msm LMammmm
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CEH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1398 11/16/95 4 Seth Beidron 11/17/95 Nancy Berry
Lab# CA95.1398 CA95.1399 CA95.1400 CA95.1401
Sample ID# 12256HSM95 12257HSM95 12258HSM95 12259HSM95
Results of Analysis
Fibers Counted
5.5 .
7.0 35.5
1.0
Fields Counted
100
100 100 100
Air Volume (liters)
479.25
481.5
1224.0
____
Fiber Concentration (fibers/cc)* <0.010
<0.010 0.014
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
K 008377
jaiatiaw"* -*r
iflf ii.m i
Willi
.*-g.
HfHISiliiiigiiiiii
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1428 11/18/95 5 Seth Beidron 11/20/95 Nancy Berry
Lab# CA95.1428 CA95.1429 CA95.1430 CA95.1431 CA95.1432 Comments:
Results of Analysis
Sample ID#
Fibers Counted
Fields Counted
Air Volume (Titers)
Fiber Concentration (fibers/cc)*
12260HSM95
4.5
100 866.25
<0.006
12261HSM95 12262HSM95
19.5
--
100 1194.24
--
0.007 -NA-
12263HSM95 12264HSM95
8.0 2.0
100 1234.0
100 ....
<0.004 BLANK
Sample #12262HSM95 could not be analyzed due to excessive dust and dirt particulates on the filter membrane which occluded the fields of view.
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory l.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
,
/j Tony Mills
~
`laboratory Supervisor
K008378
v.-a&aa3feri-*i: ti4 l 1
it! l&i mi :---- - *. . < UBa
. AT jfglUMUBi...; .fcff .&
jamms
wmimommmm
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1438 11/20/95 2 Seth Beidron 11/20/95 Nancy Berry
Lab # CA95.1438 CA95.1439
Sample ID# 12265HSM95 12266HSM95
Results of Analysis
Fibers Counted
8.0
2.0
Fields Counted
100
100
Air Volume (liters)
1224.0
Fiber Concentration (fibers/cc)*
<0.004
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory IX). #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
/Tony Mills Laboratory Supervisor
K 008379
MSM HAEOMATOMMS
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1489 11/20/95 3 Seth Beidron 11/26/95 Rudy Orta
Lab # CA95.1489 CA95.1490 CA95.1491
Sample ED# 12267HSM95 12268HSM95 12269HSM95
Results of Analysis
Fibers Counted
46.5
64.5
0.0
Fields Counted
100
100
100
Air Volume (liters)
945.0
940.8
....
Fiber Concentration (fibers/cc)*
0.025
0.034
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Ruie A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
Pony Mills Lai atory Supervisor
K 008380
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 ' Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1470 11/22/95 4 Seth Beidron 11/22/95 David Ramirez
Lab# CA95.1470 CA95.1471 CA95.1472 CA95.1473
Results of Analysis
Sample ID# 12278HSM95 12279HSM95 12280HSM95 12281HSM95-A
Fibers Counted
25.5 79.5
0.0 5.5
Fields Counted
100 100
100 100
Air Volume (liters) 134.4 130.5
--
1240.0
Fiber Concentration (flbers/cc)*
0.095 0.305
BLANK <0.004
Analytical Methcxi - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
ny Mills Labi 'atory.Supervisor
K 008381
iiateaai.fc-.. j=-------: -jj/
r1aiiaBiiatii..fei!:l
mm
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc.
Richard P. Griffin
President, CEH, CSP
CA.190.115
-
Koch Refinery West Plant
January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1467 11/21/95 3 Seth Beidron 11/22/95 David Ramirez
Lab# CA95.1467 CA95.1468 CA95.1469
Sample ID# 12274HSM95 12275HSM95 12276HSM95
Results of Analysis
Fibers Counted
4.0
8.0
1.0
Fields Counted
100
100
100
Air Volume (liters)
711.9
706.5 ......
Fiber Concentration (fibers/cc)*
<0.007
<0.007
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
<0 Tony Mills oratory Supervisor
K 008382
HSM MBOmmEMS
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP
CA.190.115 Koch Refinery January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1297 11/06/95 5 Seth Biedron 11/07/95 Nancy Berry
Lab# CA95.1297 CA95.1298 CA95.1299 CA95.1300 CA95.1301 Comments:
Results of Analysis
Sample ID#
Fibers Counted
Fields Counted
Air Volume (liters)
Fiber Concentration (fibers/cc)*
12229HSM95
7.0
100 971.8
<0.005
12230HSM95 12231HSM95
8.0
--
100 980.84
--
<0.005 -NA-
12232HSM95 12233HSM95
20.0 4.0
100 1151.4
100 ....
0.007 BLANK
Sample #12231HSM95 could not be analyzed due to excessive dust and dirt particulates on the filter membrane which occluded the fields of view.
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
//Tony Mills L,4porraatory Supervisor
K 008383
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CEH, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1521 11/28/95 3 Seth Beidron 12/04/95 David Ramirez
Lab# CA95.1521 CA95.1522 CA95.1523
Sample ID# 12286HSM95 12287HSM95 12288HSM95
Results of Analysis
Fibers Counted
20.3
21.5
3.0
Fields Counted
100
100
100
Air Volume (liters')
701.4
695.3 ....
Fiber Concentration (fibers/cc)*
0.012
0.013
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
/yTi'ony Mills LgKoorraatory Supervisor
K 008384
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CLH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1524 11/29/95 3 Seth Beidron 12/04/95 David Ramirez
Lab# CA95.1524 CA95.1525 CA95.1526
Sample ID# 12289HSM95 12290HSM95 12291HSM95
Results of Analysis
Fibers Counted
5.0
3.0
2.0
Fields Counted
100
100
100
Air Volume (liters)
438.8
438.8 ....
Fiber Concentration (fibers/cc)*
<0.011
<0.011
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory ID. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
K 008385
wan:
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1527 11/30/95 3 Seth Beidron 12/04/95 David Ramirez
Lab# CA95.1527 CA95.1528 CA95.1529
Sample ID# 12292HSM95 12293HSM95 12294HSM95
Results of Analysis
Fibers Counted
19.0
7.0 1.0
Fields Counted
100
100
100
Air Volume (liters) 911.3 856.5
....
Fiber Concentration (fibers/cc)*
0.010
<0.006
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
// Tony Mills Laboratory Supervisor
K 008386
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, QH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1496 11/27/95 4 Seth Beidron 11/28/95 Rudy Orta
Lab # CA95.1496 CA95.1497 CA95.1498 CA95.1499
Results of Analysis
Sample ID# 12281HSM95-B 12282HSM95 12283HSM95 12284HSM95
Fibers Counted
28.5 21.0
1.0
16.5
Fields Counted
100 100 100 100
Air Volume (liters) 236.25 436.5
--
1224.0
Fiber Concentration (fibers/cc)*
0.058 0.023 BLANK 0.006
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
Tony Mills boratory Supervisor
K 008387
nm MMommmm
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CEH, CSP
CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1317 11/07/95 3 Seth Beidron 11/15/95 Rudy Orta
Lab# CA95.1317 CA95.1318 CA95.1319
Sample ID# 12234HSM95 12235HSM95 12236HSM95
Results of Analysis
Fibers Counted
250.0
5.0
0.0
Fields Counted
20
100
100
Air Volume (liters)
236.28
900.00 ....
Fiber Concentration (fibers/cc)*
2.649
<0.006
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
<(yh'ju ...... /TTony Mills
Laboratory Supervisor
K 008388
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1314 11/02/95 3 Seth Beidron 11/15/95 Rudy Orta
Lab # CA95.1314 CA95.1315 CA95.1316
Sample ID# 12221HSM95 12222HSM95 12223HSM95
Results of Analysis
Fibers Counted
17.0
13.5
1.0
Fields Counted
100
100
100
Air Volume (liters)
610.2
877.5
....
Fiber Concentration (fibers/cc)*
0.013
0.007
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638 NA - Not Analyzed * - Indicates measurements corrected for blanks.
1
ff/Jl/Q (A /'n'ony Mills Laboratory Supervisor
K 008389
WMM3.
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996 _
Lab Service #: Date Collected: No. of Samples:
Submitted By: Date Analyzed: Analyst:
CA95.1311 11/01/95 3 Seth Beidron 11/15/95 Rudy Orta
Lab # CA95.1311 CA95.1312 CA95.1313
Sample ID# 12218HSM95 12219HSM95 12220HSM95
Results of Analysis
Fibers Counted
7.5
11.5
2.0
Fields Counted
100 100
100
Air Volume (liters)
877.5
869.12
Fiber Concentration (fibers/cc)*
<0.006 0.005
BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
Lony Mills Oratory Supervisor
K 008390
ESM EABOmmiMES
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CIH, CSP CA.190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1306 11/03/95 5 Seth Beidron 11/13/95 Rudy Orta
Lab # CA95.1306 CA95.1307 CA95.1308 CA95.1309 CA95.1310
Sample ID# 12224HSM95 12225HSM95 12226HSM95 12227HSM95 12228HSM95
Results of Analysis
Fibers Counted 100.0
10.0 0.0 14.0 7.0
Fields Counted
94
100 100 100 100
Air Volume (liters) 237.3 558.22
1216.8
____
Fiber Concentration (fibers/cc)* 0.211 0.009 BLANK 0.003 BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Rule A) NIOSH PAT Laboratory I.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
,/Jony Mills Laboratory Supervisor
K 008391
1245 West Cardinal Drive * Beaumont, Texas 77705 (409) 842-4094 * Fax: (409) 842-4099
Client: Attn:
Project #: Site: Report Date:
Health & Safety Management, Inc. Richard P. Griffin President, CEH, CSP CA. 190.115 Koch Refinery West Plant January 19, 1996
Lab Service #: Date Collected: No. of Samples: Submitted By: Date Analyzed: Analyst:
CA95.1340 11/09/95 4 Seth Beidron 11/14/95 Rudy Orta
Lab# CA95.1340 CA95.1341 CA95.1342 CA95.1343
Sample ID# 12240HSM95 12241HSM95 12242HSM95 12243HSM95
Results of Analysis
Fibers Counted
4.0
101.5 34.0
4.0
Fields Counted
100
60 100 100
Air Volume (liters)
906.75
418.1
364.5
....
Fiber Concentration (fibers/cc)* <0.006
0.198 0.041 BLANK
Analytical Method - Phase Contrast Microscopy (NIOSH 7400/Ruie A) NIOSH PAT Laboratory l.D. #10638
NA - Not Analyzed * - Indicates measurements corrected for blanks.
/s\ /Tbny Mills Labpratory Supervisor
K 008392