Document 5LkznyRgvMLzJXp61YQVBJJjR
PLAINTIFF'S EXHIBIT
11961 ' uft( l
boiler-burner models and boilers
Oakmont oil-fired boilers.
MERiGAisr-^tandarA
arerorsream neat'5**91'*
12125
o
3 Oil heating unit for residential and commercial installations-The Oakmont oil-fired unit is specially de signed to provide clean, modern hot water or steam heat. Built exclusively for automatic operation with oil, the Oakmont is available in a wide range of sizes for both larger residential and commercial installations.
Outstanding features of the Oakmont are its efficiency, economy and durability. Peak efficiency is the result of skillful design and precision engineering. For example, each major component that comprises the quality proven boiler-burner unit--the rugged boiler sections, Model DH-5 Arcoflame burner, automatic controls, special combustion chamber and built-in water heater-has been completely integrated and tested to produce the finest in dependable, low-cost oil heating comfort.
The long life, corrosion-resistant castings of the Oakmont are machine ground to assure an airtight, iron-to-iron fit. Each sec tion must undergo rigid inspection and testing at 2Vz times normal operating pressure. This careful attention to quality results in years of dependable, customer-satisfying heating comfort.
Jacket designed for easy assembly and servicing-- One of the principal features of the Oakmont oil unit is its ease of servicing. An attractive jacket completely encloses the boiler. An optional jacket extension encloses burner and controls offering easy access to them.
The Oakmont jacket is fabricated from sturdy steel with slip-joint construction for easy assembly and perfect fit. It is attractively styled with modern, small radius corners and is finished in a harmonizing shade of gray that is highly resistant to heat, chipping, and scratching.
The Model DH-5 Arcoflame oil burner--is an integral part of the Oakmont boiler-burner unit. Technical skill, fine materials and rigid manufacturing standards make this high pressure burner a superior companion for the Oakmont. It is fully laboratory, field and factory tested to assure compliance with rigid American-Standard requirements. Precision die-cast aluminum housing provides ease in handling. The Model OH-5 Arcoflame burner is sling mounted with a unique hanger ar rangement which assures smooth operation and easy, low-cost installation. It burns No. 1 or No. 2 fuel oil.
American-Standard Oakmont oil heating units have ratings approved by the Institute of Boiler and Radiator Manu facturers and are constructed to the specifications of the American Society of Mechanical Engineers. The Model DH-5 Arcoflame oil burner is listed by Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil, complies with Commercial Standard CS-75 and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts and by the Department of Police, State of Connecticut.
I
12126
12127
' `I
e
nt* ratings?
if heating unit
ltM
water
bteter team water
MtlsBsIt ratine a
steam
water
ttu/hr <*tt te/ltr
! =gra=ta*
!==
burner
chimemy
output capacity tin height
te/hr fRh inches feet
built-in water heaters
stock ne.
type
capacity-gats. 1ST bailer water temp.
*S 8408 *W840B *S84 *W84 107300 447 107300 143,000 1.40 8x8 20 S850B *W850B *S85 *W8S 131300 547 131300 175,000 1.75 8x8 25 S 86 OB W86OB S86 W 86 151,500 631 151,500 202,000 2.00 8x8 2S S 87 OB W870B S 87 W 37 172300 719 172,500 230,000 230 8x12 30
S88OB W88OB S 88 W88 195,800 816 195,800 261.000 2.55 8x12 30 S 89 OB W890B S 89 W89 216,100 900 216,100 288,000 230 8x12 35
583 tankless 585 tankless 597 tankless
3 per min. 3% per min. 4% per min.
599 tank
100
Any of the above built-m water heaters mey be used with any Oakmont boiler.
Oil heating unit number includes Model OH-5 Arcofteme oil burner. Note: Nozzle sizes, gph, 0* S. furnished with Oskmont oil heating units: No. S4, 1.35; No. 85, 145; No. M. 2.00; No. 17. 2^5; No. 88. 2.50; No. 89. 2.75.
equipped with crown sheet baffle.
Net l = B = R ratings shown include allowances for normal piping loss and pick up load. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements.
dimensions and tappings
extended -- jacket
3' `agings
flush jacket
:.ra;.av
o
<
boiler number A B
C
D
L
S or W 84 14 _ 26% 15
40%
S or W 85 14 - 30% 18% 44 V4
extended S or W 86 14
7 26% 22
47%
jacket
S or W 87 14
7 30V. 25% 51%
S or W 88 14 14 26% 29
54%
S or W 89 14 14 30V. 32% 58%
Flush jacket
boiler number
Sor W84 S or W 85 S or W 86 S or W 87 S or W 88 S or W 89
:jT3a3v ;v3t,?r, 3
AB
14 _ 14 _ 14 7 14 7 14 14 14 14
c
11 14% 11 14% 11 14%
D
15 18% 22 25% 29 32%
L
25 28% 32 35% 39 42%
assemblage of sections
boiler numBtr
arrangtment of tactions
S or W84 S or W 85 S or W 86 S or W 87 S or W 88 S or W 89
legend:
F-CX-B F-CX-NC-B F-CX-CX-B F-CX-CX-NC-B F-CX-C-CX-B F-CX-C-CX-NC-B
F-7" front section C-7" center section CX-7" center connecting section NC-3V2- narrow center section B-6Vj" bee* section
control applications
location sizo on boiler inches
steam or vapor
1
external low water control or feeder
2V?
IVj
msrrted m smoke pipe
1`'4
internal low water cut-off
operating temperature control for tankless heaters operating temperature control for tank type heaters
blow-off pressure control* safety waive
stack control
"A" alternate water limit control "B" reverse acting water temperature control
water limit control
operating temperature control for tankless heaters
operating temperature control for tank type heaters
alternate water limit control
not used
relief valve
stack control
vapor control on vapor boiler
^ American-Standard Oakmont Oil-fired Heating Units are another development in hydromes-the science of heating and cooling with water.
AMERICAN-*$tandard PLUMBING AND HEATING DIVISION
AMERICAN RADIATOR A STANDARD SANITARY CORPORATION 40 WEST AOTH STREET NEW YORK 18. NEW YORK
12128