Document 5LO7r8kR1ZGkm7Z6J1vrQQvX0

POLYCHLORINATED BIPHENYLS (PCBS): SOURCES AND REGULATIONS Background information for the virtual - elimination pilot Project Prepared for U.S. EPA Great Lakes National Program Office Contract #65-C8-0066 Prepared by ROSS & ASSOCIATES ENVIRONMENTAL CONSULTING, LTD. Under Contract to Science Applications International Corportation V V" 1218 Third Avenue, Suite 1207 Seattle. Washington 98101 September 12,1994 ^ #c< '' wo*"*1 *s ,t.'v `Vv Printed on Recycled Paper (206) 447-1605 Fax (206) 447-0956 ACKNOWLEDGEMENTS Ross & Associates would like to thank the many reviewers and other participants who contributed information and insights to this background material. Discussions with EPA staff, including GLNPO, Region 5, and headquarters, as well as representatives from each of the Great Lakes states helped shape many of the ideas included here. Special thanks are due to the following individuals who reviewed earlier drafts of this material. Tony Baney, Chief Operations Branch, Chemical Management Division, U.S. EPA Office ofPollution Prevention and Toxics Jim Lingle, Wisconsin Electric Tony Martig, U.S. EPA Region 5 PCB Section Tom Simons, Chemical Management Division, U.S. EPA Office ofPollution Prevention and Toxics J TABLE OF CONTENTS I. Introduction.................................................................................................................................. 1 II. What are the Sources of PCBs?............................................................................................. A. Items containing intentionally introducedPCBs........................................................ 1) Allowable uses ...................................................................................... 2) Discontinued Uses of PCBs .......................................................................... B. Inadvertent Generation of PCBs................................................................................ C. Waste Disposal Facilities ........................................................................................... D. Data Sources for the Great Lakes States................................................................... 4 4 5 7 8 8 9 III. Environmental and Health Concerns .................................................................................. 13 IV. How are PCBs Regulated? ......................................................................... ..........................14 A. TSCA Regulations ........................................................................................................14 1) Allowable Uses of PCBs...................................................................................18 2) Disposal / Storage Costs ...................................................................................19 B. Other Regulations Governing PCB Releases .............................................................20 V. Non-Regulatory Programs ............ 24 VI. Potential Changes in PCB Regulation.................................................................................... 26 A. Disposal Amendments ................................................................................................. 26 B. Transformer Reclassification Rules ............................................................................27 Appendix A: PCB Use Tree Appendix B: PCB Activities / Uses Allowed Under TSCA Appendix C: Exemptions for Manufacturing, Processing, and Distribution Appendix D: Regulatory Framework for PCB Disposal Appendix E: Commercially Permitted PCB Disposal Companies Appendix F: Issues Considered in PCB Disposal Amendments Appendix G: Comparison of Transformer Reclassification Rules (Existing and Proposed) - Appendix H: Data on PCB Releases LIST OF TABLES Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Outline for PCB Approach Categories of PCB Use Allowed Under TSCA TRI - PCB Releases and Transfers, the Eight Great Lakes States TSCA Framework for Regulating PCBs -- Summary TSCA Framework for Regulating PCBs TRI - PCB Releases and Transfers, the Eight Great Lakes States Overview of Proposed Changes in Transformer Reclassification Rules Virtual Elimination Pilot Project PCB Sources and Regulations Background Information on PCB Sources and Regulations I. Introduction Polychlorinated biphenyls (PCBs), although banned or tightly restricted in almost all industrial and commercial uses because of their persistence and high toxicity, remain a major cause of contamination in the waters of the Great Lakes. All five of the Great Lakes -- as well as numerous inland lakes -- have fish consumption advisories as a result of PCB contamination. PCBs refer to a class of chlorinated, chemical compounds that includes numerous different substances favored for their low conductivity, high boiling point, chemical stability, and flame retardant properties. Throughout the 20th century, PCBs were used for many diverse purposes ranging from dielectric fluids to pesticides. As evidence of their toxicity took shape, their uses were curtailed sharply. In a span of less than 20 years, PCBs have moved from one of the most widely used chemicals to one of the most tightly controlled. Today, PCBs represent the only substance singled out for a customized regulatory framework, a self-contained system under which owners and users must operate. It is a series of regulations unmatched for any other industrial chemical. Although most PCB-related activities have been banned or tightly restricted, PCBs still remain in industrial and commercial use in allowable circumstances. PCBs previously released into the environment are dispersed in the air and water and are located in landfills and sediments. Over half of the PCBs manufactured were disposed of prior to the enactment of specific regulations. Consequently, pathways exist for PCB exposure, and PCBs are still considered a threat to human health and the environment. For this reason, PCBs have been included in the Virtual Elimination Pilot Project. Ross & Associates Environmental Consulting, Ltd Page 1 Virtual Elimination Pilot Project PCB Sources and Regulations The challenge for the Virtual Elimination Project is three-fold. It seeks to identify incentives necessary to encourage accelerated phaseout and proper disposal of PCBs in (1) specifically regulated and known items such as transformers and capacitors, (2) known but unregulated items, such as non-leaking capacitors in fluorescent lamp ballasts, and (3) those circumstances where PCBs are "unknown" either by source and/or location. PCBs also reside in sediments, hazardous waste sites, and other areas as a result of past use and disposal practices. Because the Virtual Elimination project is focusing on current and future use and disposal practices, these sources are not included in the analysis. These sources of PCBs are addressed by current remediation programs. Several recent efforts may change substantially the way in which PCBs are regulated and the manner in which they are disposed. The Virtual Elimination project will explore these current efforts and seek other appropriate options that would result in more rapid and proper PCB disposal. This background report addresses the following issues: (1) What sources potentially release PCBs into the environment? (2) What regulations affect PCB use and disposal? The discussion focuses on current TSCA regulations and possible changes to these regulations, as they shape PCB use and disposal decisions. (3) What non-regulatory programs encourage reductions in PCB use and disposal? (4) What potential changes to PCB regulations are in progress? The objective ofthis background information is to provide a context for understanding how PCBs are currently used, past uses that might contribute to current PCB releases, and the extent to which the current regulatory structure is encouraging -- or hindering -- timely and proper disposal of PCBs. From this information, recommendations can be developed to enhance proper PCB disposal. Table 1 outlines the approach used for PCBs in the Virtual Elimination project. Page 2 Ross & Associates Environmental Consulting, Ltd. 1`CII Siiiuti's mul ltvgnhiliiins Table 1: OUTLINE FOR PCB APPROACH Overall Objective: What we are looking for: Timely and proper disposal of existing PCBs Incentives to encourage accelerated phaseout and proper disposal 3-pronged approach that covers: 1) Specifically regulated items 2) Unregulated items 3) Unknown sources Source Category Regulated and known items (e.g. transformers, capacitors) Cause of Problem Challenge/Obiective Regulatory framework does not include incentives for rapid disposal (no remaining phaseout requirements) Identify opportunities to increase benefits associated with rapid and proper disposal Unregulated items (e.g. fluorescent lamp ballasts) No specific disposal requirements (may be disposed ofas municipal solid waste, unless leaking--state laws vary) Identify incentives necessary to obtain better disposal Unknown PCBs (difficult to track and enforce legal disposal) 1) Unknown sources/uses (newly discoveredpast uses, such as corrosion protectionfor metal surfaces) Identify sources and proper regulatory/incentive structure Ross & Associates Environmental Consulting. Ltd 2) Unknown location and/or uninformed owner of PCB items (e.g. people who have PCB items but are not aware oftheirpresence, or regulatory requirements) Identify appropriate incentives for source identification and proper disposal OWll/MPCBOBI.XLS Virtual Elimination Pilot Project PCB Sources and Regul;< : ns II. What are the Sources of PCBs? From 1929-1977, Monsanto Company, the sole manufacturer of PCBs in the United States, produced 700,000 tons of PCBs. Due to their low flammability, PCBs were used extensively for insulating and cooling electrical equipment, particularly in transformers, large capacitors, and fluorescent lamp ballasts. Annual PCB sales peaked at 85 million pounds in 1970. Recent estimates suggest that 141,000 tons of pure PCBs remained in service at the end of 1988. In the United States PCBs are, for the most part, no longer used deliberately in product manufacture. PCBs aie released to the environment from (1) items that contain PCBs introduced deliberately for their useful chemical properties, (2) inadvertent generation during certain production processes, and (3) storage and disposal facilities. A brief discussion of the different categories of potential PCB sources follows. This section concludes with a discussion of PCB release data available from several federal and state reporting programs. Appendix A, a detailed "use tree" of PCB sources, illustrates the diverse applications of PCBs before their general use was curtailed. A. Items containing intentionally introduced PCBs The majority ofPCBs were used in the production ofdielectric fluids for transformers, capacitors, and other electrical components. PCBs were also used in synthetic resins, epoxy paints and protective coatings, and hydraulic and heat transfer fluids (due to their high boiling point). Because of its low flammability property, many past uses of PCBs may not be known to regulators today. For instance, it was only recently discovered that the U.S. Navy painted some ships with paints that incorporated PCBs, which now causes difficult disposal issues. Today, none of these items may be designed or manufactured with PCBs. Under current regulations, these uses must be recognized specifically by regulation, or are not allowed at all. However, items such as large appliances, transformers, fluorescent lamp ballasts, and many other products created before PCBs were banned have a long useful life, and thus, many ofthese items remain in service. In some cases, owners may not know that items on their property contain PCBs. The challenge for the virtual elimination project is to develop ideas that result in accelerated phaseout and proper disposal of these and other remaining PCBs. Page 4 Ross & Associates Environmental Consulting, Ltd. Virtual Elimination Pilot Project PCB Sources and Regulations 1) Allowable uses TSCA regulations, described in detail in section IV, include provisions for allowable uses of PCBs within its overall ban. Transformers and capacitors, the largest reservoirs of PCBs still in use, are included in this category. Under TSCA, all uses of PCBs are banned unless they fall into one of the following categories of allowable uses: (1) "totally enclosed" activity; (2) authorized uses; or (3) exemptions obtained through specific petition. In addition to uses allowed in these three categories, several other activities are allowed without explicit authorization or exemption, provided the PCB concentration falls below the regulatory concentration limit: (1) the inadvertent generation of PCBs; (2) use or processing of excluded products; (3) use or processing of recycled PCBs; and (4) applying sewage sludge that contains less than 50ppm PCBs. Table 2 summarizes these allowable use provisions. Appendix B lists the specific activities allowed under each category. Why are certain PCB uses and activities still allowed? EPA has determined that certain PCB uses pose no unreasonable risk. This threshold of "no unreasonable risk" is the underpinning of the TSCA regulatory framework. Some PCB activities that EPA considers to pose "no unreasonable risk" avoid TSCA's regulatory levers. a. Electrical Equipment PCBs were used as electric current-insulating material and coolant in electrical equipment to prevent overheating and fires. Electrical products that relied on this type of insulation include transformers, capacitors, voltage regulators, and lamp ballasts. Capacitors containing PCBs were also used in refrigerators, air conditioners, and other large appliances. Industrial machinery and other electrical equipment also relied on PCBs' fire resistant and insulating properties. The primary concerns with this type of equipment result from spills, fires, and improper disposal. Identifying all potential owners of equipment containing PCBs is quite difficult. Transformers and capacitors. Transformers and capacitors are the focus of numerous regulations. Restrictions on allowable uses have tightened over the years since TSCA regulations were first promulgated. Transformer fires may release dioxin from incomplete combustion of PCBs. Current regulations, described in more detail in Section IV impose strict requirements on the locations of these items, and require recordkeeping, monitoring, marking and other obligations for owners. However, all phaseout dates for these items have already past. These phaseouts restricted the locations of PCB-transformers. .................... Ross & Associates Environmental Consulting, Ltd Page 5 Virtual Elimination Pilot IVoject PCD Sources and Kcguhifimts Table 2: CATEGORIES OF PCB USE / ACTIVITIES ALLOWED UNDER TSCA PCBs may still be used in a variety of ways. Under TSCA, PCBs may be used, manufactured, distributed, processed and/or imported or exported if the activity fits into one of the categories below. Each allowable activity has its own set of conditions (hat restrict use and disposal, and include a wide range of requirements such as marking, registration, notification, etc. Definition Comments "Totally Enclosed" Use "ensures that exposure of human beings or the environment to PCBs as a result of the activity will be insignificant" (TSCA 6(e)) Definition applies to distribution in commerce of intact non-leaking electrical equipment such as transformers, capacitors, electromagnets, voltage regulators, switches, circuit breakers, etc. (40 CFR 761.20) Authorized Use Exemptions Activities specifically authorized, based on finding that they will not present an "unreasonable risk" (40 CFR 761.30). The largest categories of remaining PCB use fall in this category (e.g., transformers and capacitors). Each has a list of conditions required for compliance (see Appendix A.) Granted by petition approval process; based on showing of no unreasonable risk and good faith effort to develop substitute; granted for one year with opportunities for renewal. 6(e)(3)(B) Exemptions may change over time. Some have automatic renewals, others change annually. Inadvertent Generation By-product of an excluded manufacturing process (must meet five-part definition to qualify) Excluded Products Recycled PCBs No special authorization required for use of PCBs with less than 50 ppm. PCBs used in the processing of paper products or asphalt roofing materials. Ross & Associates EnvironmentalConsulting, Ltd. Processes allowed, but subject to certification, recordkeeping, and reporting requirements; limits on PCB concentration in product, and air/water releases. Limits on PCB concentration in product and air/water releases. ti*8KB&xiwjKtisnxis 99/11/94 Virtual Elimination Pilot Project PCB Sources and Regulations The majority of transformers are owned by utility companies. Regulators are concerned that (1) improper transformer servicing and disposal may result in spills and leaks to the environment, and (2) building owners may not be aware of a transformer containing PCBs on their premises. As discussed in Section V, EPA Region 5 is exploring options to promote a more rapid phaseout of PCB transformers. Lamp ballasts. All fluorescent lamps manufactured before 1979 probably contain PCBs. However, they are not labeled as such. Only lamps manufactured after 1979 are labeled to indicate they do not contain PCBs. Because of the potential for future environmental liability, many building owners and others responsible for large quantities of discarded light ballasts are exploring combinations of incineration and recycling instead of landfill disposal. Several companies offer cleanup disposal services. Large building owners are likely aware of potential PCBs in their lamps, however, smaller owners may not be aware of this potential PCB source. PCB ballast capacitors contain about 1 ounce of PCB dielectric fluid. Industry sources estimate that approximately 1 billion ballasts are in use in the United States. Ballasts with non-leaking small capacitors may be disposed of in sanitary landfills, although EPA encourages disposal in chemical waste landfills or incinerators. In Minnesota, large quantities of fluorescent lamp ballasts are considered hazardous waste, and must be disposed of accordingly. b. Non-Electrical uses PCBs used in inks and carbonless copy paper may cause paper mills and de-inking operations handling recycled fiber to generate PCBs in their effluent. Metal casting plants with PCBcontaining hydraulic fluids are also potential sources of PCB releases. PCBs were also used in paints, adhesives, sealants, pesticides, plasticizers, and as lubricants. As indicated below, many of these uses are no longer allowed under any TSCA provisions. 2) Discontinued Uses of PCBs Several previous uses of PCBs are not authorized or provided for under any TSCA provisions. These items may remain in circulation even if they are no longer produced. The following list illustrates products that have, in the past, contained PCBs although PCBs are no longer allowed in these items: Adhesives, construction materials, cutting oils, dedusting agents, fuel tank coatings, gaskets, inks, oil/lubricants for vacuum pumps, air compressors, and gas transmission turbines, paints, pesticide extenders, plastic electrical cable insulation, plasticizers in rubber, plasticizers in synthetic resins, sound deadening felt, viscosity testing liquids. Ross & Associates Environmental Consulting, Ltd. Page 7 Virtual Elimination Pilot Project PCB Sources and Regulations B. Inadvertent Generation of PCBs Any chemical process that involves carbon, chlorine, and elevated temperatures may inadvertently generate PCBs. EPA has estimated that up to 200 chemical processes may inadvertently generate PCBs. For example, many of these processes are used to produce chlorinated solvents. In addition, numerous other products, such as paints, printing inks, agricultural chemicals, plastic materials, and detergent bars, may contain inadvertently generated PCBs. The concentration of inadvertently generated PCBs in products leaving any manufacturing site or imported into the United States must have an annual average of 25 ppm, with a 50 ppm maximum. The concentration of PCBs in detergent bars must be less than 5 ppm. In 1984, EPA weighed the health and environmental risks and the economic costs of allowing these processes to continue. At that time, EPA concluded that the quantity of PCBs released to the environment from these ongoing processes was inconsequential compared to the quantity of PCBs released to the environment from items that contained intentionally introduced PCBs. For that reason, EPA decided against an outright ban of these processes, due to the potential for a major disruption in commerce. Specifically, EPA recognized that the high costs associated with eliminating the low risks posed by inadvertently generated PCBs would place an excessive cost on society in light of the minimal reductions in public health risks that would accrue. Instead, EPA decided to add certification, recordkeeping, and reporting requirements to facilities that inadvertently generated PCBs, in combination with the specified regulatory concentration limits for air and water releases. Inadvertently generated PCBs vented to ambient air must be less than 10 ppm. The amount of inadvertently generated PCBs added to water discharged from a manufacturing site must be less than 100 ppb. C. Waste Disposal Facilities Under TSCA regulations, items containing PCBs must be disposed of in specified disposal facilities. However, some items, such as non-leaking fluorescent lamp ballasts, may be disposed of as municipal solid waste. These items may release PCBs if they break during disposal. TSCA regulations outline operating standards and procedural requirements for incinerators and chemical waste landfills. Disposal contracts must specify that only EPA permitted or approved facilities will be used. Improper disposal may result in generator liability. Page S Ross & Associates Environmental Consulting, Ltd. Virtual Elimination Pilot Project PCB Sources and Regulations Wastewater Treatment Plants. Some wastewater treatment facilities in the Great Lakes states detect PCBs in their effluent. The specific source of these PCBs will vary by treatment plant, and may include contaminated sediments, illegally disposed PCBs, and other sources. Treatment plants such as the Western Lake Superior Sanitary District in Minnesota have aggressive programs to determine the sources of PCBs to their facilities. Incinerators. PCBs are destroyed almost completely when incinerated in a TSCA-approved incinerator burning at permitted operating temperatures. The minimum operating temperature for PCB liquids > 500 ppm is 1200 degrees Celsius (2200 degrees fahrenheit). TSCA operating permits and regulations prohibit adding PCB feedstock during start-up or shut-down. Combustion processes, such as incinerators, boilers, and furnaces, may not reach a high enough temperature to destroy PCBs if they bum items containing PCBs during startup or shutdown. PCBs may convert to dioxins ifthey are not destroyed properly. EPA does not have as tight control over the operating conditions at boilers and industrial furnaces that bum wastes, or used oil as fuel, as it does for TSCA-permitted incinerators. Landfills. Landfills are a potential source of PCB release to the environment due to past disposal of PCB-containing items as well as current, allowable disposal ofPCB-containing items. Landfill operators must monitor the groundwater for PCB contamination. D. Data Sources for the Great Lakes States PCB releases and transfers are reported under several reporting programs, each with a different set of regulatory requirements, and each covering a different subset of the regulated community. The primary sources of PCB release information are (1) the Toxic Chemical Release Inventory (TRI), (2) Permit Compliance System (PCS) of water discharges, (3) the National Response Center for information on PCB spills, and (4) the Notification and Manifesting Rule for PCB disposal. In addition to these federal reporting programs, some Great Lakes states maintain other reporting systems that provide additional information on PCB releases. Data is included for Wisconsin air point sources and Michigan's Critical Materials Wastewater Report. Information from each ofthese sources is summarized below, and included in detail in Appendix H. With the exception of TRI data, all information is shown by SIC code to illustrate the distribution of PCB releases across different industrial sectors. Appendix HI provides a summary of the number of facilities that report PCB releases under each of these programs, and shows how the number of facilities varies by reporting program as a result of differing reporting requirements. For instance, 360 facilities in the Great Lakes states report PCBs under Michigan's Critical Materials Wastewater Reporting program, while only 9 facilities report PCB releases under TRI. Ross & Associates Environmental Consulting, Ltd. Page 9 Virtual Elimination Pilot Project PCB Sources and Regulations Region 5 has also estimated the number ofremaining PCB transformers and capacitors as part of its efforts to phaseout this equipment. EPA estimates that Region 5 may have 17,500 PCB transformers and 400,000 PCB capacitors. Many of these items have several years left of useful life. As PCB equipment approaches the end of its useful life, spills become more common. EPA estimates that 3.3% oftransformers and 0.75% ofcapacitors will spill, with 560 transformer leaks and spills, and 3000 capacitor leaks and spills annually. Utilities in the Great Lakes states estimate that they have already removed 87% of their PCB equipment. Toxic Chemical Release Inventory (TRI). Appendix H2 shows TRI PCB releases for the Great Lakes states. TRI tracks chemical releases from facilities in the manufacturing sector (SIC codes 20-39) that meet reporting thresholds. TRI thresholds are based on the quantity of each substance used, processed, manufactured, or imported at any of these facilities. Appendix H2a includes 1992 data for the eight Great Lakes states, including any source reduction activities implemented by each facility. Nine facilities reported PCB releases in 1992. All PCB releases were reported as offsite transfers. No facilities reported releases to air or water. Table 3 shows the types of releases reported in TRI. Electric utilities do not fall into the SIC code range covered by TRI, and therefore do not report any PCB activities under this program. PCS data. Appendix H3 contains data from EPA's Permit Compliance System (PCS) for water discharges. PCS data approximates point source loads from municipal and industrial dischargers. The information is based on monitoring data supplied by regulated facilities. EPA uses PCS data as the basis for its enforcement program. In 1993, eight facilities reported PCB discharges in Region 5 during 1993. Facility Kalamazoo WWTP Bay City WWTP GM-Engine Division-Bay City Alcan Sheet & Plate Division Outboard Marine - Waukegan Detroit WWTP Trenton WWTP Fort Howard Paper Company ke/vr 4.96 4.96 2.51 1.25 1.08 0.89 0.20 0.16 16.01 kg National Response Center. Spills of PCBs that exceed one pound must be reported to the National Response Center. Based on National Response Center data. Region 5 had 27% of the nation's spills from 1987-1992. Michigan, alone, had nine percent of the nation's spills, and 34% of the Region's spills. Page 10 Ross & Associates Environmental Consulting, Ltd Table 3 SOURCES PCB Releases and Transfers, The Eight Great Lakes States, 1992 DESTINATION SIC Cod* 28 Chemical and Allied Product* 2819 Industrial Inorganic Chemicals Not Elsewhere Classified (mercury, redistilled) 29 Petroleum Refining and Related Industrie* 2911 Petroleum Refining 32 Clay, Glass, Stone Product* 3241 Cement, Hydraulic 3274 Ume Products 33 Primary Metal Industries 3313 Electrometallurgical Products 3321 Grey Iron Foundry 38 Electronic and Other Electrical Equipment 3612 Transformers 3621 Motors and Generators TOTAL Quantity kg/yr 2 %of Total Total Number of Faculties n 0.0002 i 0 214,489 0 26,400 12,268 896,847 41,308 0 18 0 2 1 75 4 i i i i 2 1 1 1,191,094 100 9 Offsite transfer is the primary destination of PCBs. Destination Air Point Air Nonpoint Offsite Water Land POTW Underground TOTAL Quantity kg/yr %Of Total 0 0 1,191,093 0 0 99.99999 Facilities Reporting Release* (Out of 9) 0 0 6 00 1 0.00001 00 00 0 1 0 0 1,191,094 100 N/A Source: Toxic Chemical Release Inventory Data downloaded June 21,1994 Virtual Elimination Pilot Project PCB Sources and Regulations Wisconsin Air Point Source Emissions Data. Appendix H4 contains air emissions data for Wisconsin facilities (1992 data). As part of its Clean Air Act Title V Operating Permit Program, Wisconsin collected emissions data from facilities that reported releases greater than one pound of hazardous air pollutants, including PCBs. Three facilities reported PCB emissions under this program. This total includes two paper and allied products facilities. Michigan Critical Materials Registry. Appendix H5 includes data from Michigan's Critical Materials Wastewater Report (1991 data). As part of its water quality program, Michigan collects information on chemical use and release from facilities that use any substance, including PCBs, on the "Critical Materials Registry." It is the only program that requires facilities to report information about chemical ue. Under this program, "use" means the presence of the chemical onsite. A total of 36f -cilities reported PCB use, including 61 motor vehicle-related facilities, 21 electric utilities, an*. *3 paper mills. The total PCB use was between 12,596,890 - 12,631,657 pounds. Of this to: .1, 11 facilities reported discharges ranging in total between 114 and 627 pounds; 115 facilities reported residuals ranging in total between 916,831 and 930,556 pounds. Notification and Manifesting Rule. EPA promulgated a notification and manifesting rule in 1990 to track PCB waste disposal in a manner similar to RCRA waste disposal tracking. Under the notification and manifesting rule, storage and disposal facilities must track and report all PCB wastes received. This data illustrates the volume of PCBs disposed annually in each EPA region, but it does not track the source of this waste. Appendix H6 shows the trends in PCB disposal (at a national level) since the inception of the notification and manifesting rule. In 1992, 746 million kilograms of PCB-contaminated waste were disposed of in TSCA disposal facilities, representing an increase of 62% over 1991 PCB disposal. EPA estimates that 91% of this waste was bulk waste, most likely from remediation. The volume of PCB waste accounted for in transformers, capacitors, article containers, and containers has remained relatively constant over the three-year period. EPA regions with large PCB disposal facilities show the largest disposal volumes. Region II (NY, NJ, RI) reported 152,800,000 kilograms disposed of in 1992. Almost all of this was disposed ofat a chemical waste management PCB landfill in New York (152,500,00 kg). Region III (PA, VA, WV) reported 14,700,000 kilograms of PCB waste, and Region V reported 24,100,000 kilograms. Page 12 Ross & Associates Environmental Consulting, Ltd. Virtual Elimination Pilot Project PCB Sources and Regulations III. Environmental and Health Concerns PCBs are classified as probable human carcinogens. As a class of chlorinated compounds, PCBs may include more than 200 different isomers. The specific toxicity varies among chemical products based on the number and position of the chlorine atoms. Tests on laboratory animals show that PCB exposure can cause cancers, tumors, birth defects, reproductive failures, as well as liver, eye, and gastric tract disorders. PCBs persist in the environment after they are released. Because PCBs are stable compounds, they do not degrade rapidly, and are passed up the aquatic food chain in increasing levels in a phenomenon known as bioaccumulation. The major source ofPCB exposure for the general public is contaminated fish consumption. PCB contamination in fish and shellfish populations has resulted in closure of fisheries across the country. In addition, PCB exposure may result from servicing PCB containing products such as. transformers and other electrical equipment. These activities are also regulated under OSHA occupational safety standards at a level designed to protect against skin disorders (29 CFR 1910). Ross & Associates Environmental Consulting, Ltd Page 13 Virtual Elimination Pilot Project PCB Sources ami Regulations IV. How are PCBs Regulated? PCBs occupy a unique niche in the federal chemical regulatory arena. Singled out for special attention under TSCA, PCBs are subject to a management regime largely independent of other environmental laws. PCBs are regulated primarily under the Toxics Substances Control Act (TSCA), which dictates restrictions on the manufacture, sale, use, disposal, import and export of PCBs. The statute also includes provisions for allowable uses. TSCA is not a program delegated to the states like many other statutes. States may regulate the disposal of PCBs under their own authorities, but those rules cannot be less stringent than TSCA rules. PCB releases are also regulated by the Clean Air Act (CAA), Clean Water Act (CWA), Resource Conservation and Recovery Act (RCRA), and PCB releases are also reported in the Toxic Chemical Release Inventory (TRI). However, TSCA regulations shape the principal regulatory framework. Thus, the costs associated with having PCBs are generally independent of costs associated with other chemicals. A. TSCA Regulations TSCA establishes a legal presumption that PCBs pose an unreasonable risk to human health and the environment, unless EPA determines otherwise. TSCA regulations establish an elaborate concentration-based hierarchy that governs all aspects of PCB use and disposal, and dictates specific behaviors that are necessary for compliance. Regulations and policy specify: (1) How PCBs may be used, processed, distributed, manufactured, exported, and/or imported; (2) Acceptable storage and disposal conditions; (3) Spill clean-up requirements; and (4) Recordkeeping and reporting requirements. Each of these categories has a separate series of costs associated with it, as well as different thresholds, and criteria for achieving compliance. TSCA regulations, codified at 40CFR 761, apply to all persons who manufacture, process, distribute in commerce, use, or dispose of PCBs or PCB items, including dielectric fluids, contaminated solvents, oils, waste oils, heat transfer fluids, hydraulic fluids, paints, sludges, and spill contaminated soils. TSCA regulations apply as well to items that have been in contact with PCBs. Page 14 Ross < Associates Environmental Consulting, Ltd Virtual Elimination Pilot Project PCB Sources and Regulations TSCA relies on a theory of increasing regulatory burdens and maintaining management requirements with each higher level of PCB concentration. PCBs in concentrations <50ppm are known as "non-PCB" items. These items are generally excluded from regulation, with the exception of a prohibition on using and burning waste oil (40CFR 761.20(d) and (e)); disposal is still regulated if wastestreams are diluted to <50ppm (40CFR761.1 (b)). In addition, PCB concentrations in heat transfer and hydraulic equipment must be less than 50 ppm. Electrical equipment containing PCBs in concentrations between 50 - 500ppm are known as "PCB-contaminated" electrical equipment. These items have some recordkeeping and disposal requirements, along with specifications for storage, cleanup, and notification; and PCBs found in electrical equipment in concentrations >500ppm are known as "PCBtransformers". These items have requirements for marking, recordkeeping, inspection, cleanup, registration, notification, location, and limited disposal options. Costs associated with TSCA regulations include inspection, recordkeeping, servicing, marking, location requirements, notification and other issues. Table 4 shows the basic framework for TSCA regulations of PCBs. Table 5 highlights the major provisions within this framework. Despite the clear message of TSCA regulations, existing regulations may not necessarily encourage accelerated phaseout or proper removal and disposal of PCBs. Frequently, it is difficult to move between concentration levels, especially given TSCA's prohibition on dilution, and stringent rules for reclassifying equipment with PCBs. In addition, current regulations are noticeably lacking in requiring the elimination of PCBs in existing -- and allowable -- uses. All previously specified phaseout deadlines have come and gone. Yet, lingering over all PCB owners is the potential for heavy costs associated with leaks, spills, improper disposal, and future liability costs. TSCA violations average $25,000 per.action for violations that include paperwork errors and unauthorized uses or releases. The implication of this regulatory regime is easily recognizable: lower concentrations of PCBs (or elimination of PCBs) reduces the regulatory burden and compliance costs. Thus, the TSCA message is clear: eliminate PCBs or move to a lower threshold categoiy, and many costs associated with PCB management disappear. This clear message lies in stark contrast to regulations that affect multiple chemicals. Ross & Associates Environmental Consulting, Ltd Page 15 Yiiftial f'lmiinalitin Pilot Project l*( K SniNTCS and lU`gntntiiis Table 4: TSCA Framework for Regulating PCBs -- Summary TSCA 6(e) and regulations at 40CFR761 outline an elaborate system for allowable PCB uses / activities, and the conditions associated with use, clean-up, and disposal for each activity. TSCA regulations fall into the following categories: Allowable' : TIVITIES Criteriafor compliance: All PCB uses or activities are banned UNLESS they fit into a specifically listed category DISPOSAL/STORAGE Criteriafor compliance: Date Purpose Pollutant form Intent of storage SPILL CLEANUP POLICY Criteriafor compliance: Location of spill Quantity spilled Concentration released Date spilled (reporting, disposal, and pre-cleanup requirements are consistent with requirements in other vs) RECORDKEEPING Criteriafor compliance: What is used or stored Ross Associates Environmental Consulting, Ltd. 9/11*4110TCBS.XLWJT3CAFKAM XLS Virtual liliimnnlinn Pilol Project PCU Sources mid Regulations Table 5: TSCA Framework for Regulating PCBs Allowable USES / ACTIVITIES Criteria: all PCB uses or activities are banned unless they fit into one ojf these categories DISPOSAL/STORAGE Criteria: date, purpose, pollutant form, intent of storage SPILL CLEANUP POLICY Criteria: location of spill, quantity, concentration released, date RECORDKEEPING Criteria: what you use or store "Totally enclosed" i "ensures that exposure ofhuman beings or the environment to PCBs as a result ofthe activity trill be insignificant" (TSCA 6(e)) Authorized uses (non-enclosed) uses listed in 40CFR761.30 -- do not present "unreasonable risk" Exemptions (via petition) companies must petition for specitic usc/activity granted up to one year; may be renewed No authorization or exemption required for: Inadvertent generation by-product of excluded manufacturing process (5 parts to definition) Excluded products (<50ppm) Recycled PCBs (PCBs in processing of paper products or asphalt roofing materials) Applying sewage sludge <50ppm PCBs Past disposal (prior to 1978) - exempt unless removed from disposal site or >50 ppm is found in a non-disposal site POLLUTANT FORM determines Type of disposal permitted incineration, chemical waste landfill, or alternative (separate conditions for each) may become acute waste under RCRA if disposal facilities unavailable commercial storage and disposal facilities must be approved "In storage for disposal" store for up to one year before disposal PCB mixtures >50ppm marking, recordkeeping, inspection requirements requirements for storage facilities Spills > 50ppm Cleanup standards: * Numeric standards for spills >1987 (except into certain areas like surface water, grazing lands) * Site-specific standards (EPA Regional Office discretion) for spills <1987, and into certain areas (surface water, etc.) Reporting requirements (based on spill classification) Spill Classification: * Low concentration <500ppm and <llb High concentration >500ppm or low cone. >llb or >270 gal untested mineral oil Issues: Disposal requirements High disposal costs may inhibit disposa for spill cleanup debris * Storage for "reuse" may avoid 1-year storage limit Many items unregulated for disposat Annual Recordkeeping Requirements for the facilities that use or store:: * >45kg PCBs in PCB containers One or more PCB transformers 50 or more PCB large high or low voltage capacitors Reporting and recordkeeping requirements for commercial storage and disposal facilities: Annual records/reports - Disposal companies, transporters, commercial storers, and generators of PCB waste - waste in/waste out must be tracked Notification and Manifesting Rule tracking system for PCB wastes (since 1990) Enforcement Violations carry $25,000/violation penalty (actual average $25,000/action) Hoss dt Associates Environmental Consulting. Ltd. [IWCW jawirscAPCRjoa OMIM Virtual Elimination Pilot Project PCB Sources and Regulations PCB regulations have been revised periodically based on new risk information. In several instances, EPA has rejected additional outright bans on continued use because the societal costs of doing so far outweighed the benefits of additional risk reduction. For example, in the mid 1980s, EPA imposed additional regulatory requirements (inspection, servicing, registration, labeling, location requirements, etc) on PCB transformers to minimize fire risks instead of immediately banning them because of the estimated multi-billion dollar costs associated with electrical service disruption. EPA promulgated the "fire rule" in 1985, after reassessing its earlier position on the expected frequency of fire-related incidents involving transformers containing PCBs. PCBs released during transformer fires may be volatilized and converted into other toxic materials such as dioxins. With this rule, EPA imposed restrictions on the locations of electrical equipment containing PCBs, and required registration and marking of PCB electrical equipment. In so doing, EPA determined that the continued use of PCB transformers without these additional restrictions posed an unreasonable risk of injury to health and the environment (see "fire rule," at 50 m 29170, July 17, 1985). 4 1) Allowable Uses of PCBs In general, all PCB uses or activities are banned unless they fit into a specifically listed category. Table 2, included earlier in this report, summarized the different types of allowable uses. Appendix B describes these activities in greater detail. PCB activities are allowed in the following areas: Totally Enclosed Activities. "Totally enclosed" activities are defined in TSCA regulations as an activity that results : "no exposure to humans or the environment" (40CFR761.20). Regulations list tic distribution in commerce of certain intact, nonleaking electrical equipment as totally enclosed activities. Authorized Uses. "Authorized uses" are non-totally enclosed uses that must be specifically authorized by rule (TSCA 6(e)(2)(B)). Generally, authorized uses are based on a finding that the use will not pose an unreasonable risk of injury to health or the environment. Regulations list such authorized uses (40CFR761.30). EPA may modify this list as appropriate. For instance, in April 1994, EPA added analytical reference samples to the list of authorized uses. Exemptions. "Exemptions" are required for activities that are not considered totally enclosed, or are not specifically authorized by rule. Individuals may petition EPA to approve a one-year exemption for their specific use. EPA may grant an exemption if it determines that the activity would not pose an unreasonable risk of injury to health or the Page 18 Ross & Associates Environmental Consulting, Ltd Virtual Elimination Pilot Project PCB Sources and Regulations environment and the applicant has made good faith efforts to develop a chemical substitute. Appendix C lists the companies (as of July 1993), that have been granted exemptions for PCB activities. Until recently, these exemptions renewed automatically as long as no changes were made to the allowed activity. However, in April 1994, EPA revised the regulations governing renewals of exemptions (59 FR 16991-16999). Under the revised regulations, petitioners must submit a certified letter to EPA at least six months prior to the expiration date of the current exemption stating that the specific types ofPCB activities have not changed. Any changes to an original exemption are considered a new petition for exemption. The revised regulations apply to exemptions granted on or after April 25, 1994. 2) Disposal / Storage Costs TSCA regulations require specific disposal methods that vary by the type and concentration of PCB items. The pollutant form determines the type of disposal options available. These options include: (1) incineration in a regulated PCB incinerator; (2) disposal at a licensed chemical waste landfill; (3) disposal in a high efficiency boiler; (4) alternative disposal methods subject to EPA approval; (5) disposal as municipal solid waste; and (6) unregulated disposal. Appendix D shows the regulatory framework for PCB disposal in detail. Incineration destroys PCBs and eliminates the potential for future liability that may result from landfill disposal options. However, incineration has the highest short term costs of available disposal options. EPA approves several different methods for PCB disposal. Several PCB disposal companies operate a variety of commercially permitted disposal facilities throughout the United States. These companies offer PCB disposal related services that include incineration, alternate thermal treatment, chemical treatment, physical separation, pipeline removal, PCB transformer decommissioning (disassembly/smelting), chemical waste landfills, and biological treatment. A full list of these companies is included as Appendix E. Ross & Associates Environmental Consulting, Ltd Page 19 Virtual Elimination Pilot Project PCB Sources and Regulations EPA regulations impose a one year time limit on PCB items placed in storage for disposal. However, EPA has learned of many instances where owners of PCB equipment place it in storage in anticipation of re-use to avoid the one year time limit. EPA is evaluating this in its upcoming PCB disposal amendments. EPA has also promulgated rules that guide the approval process for commercial PCB storage facilities. EPA revised its regulations in November 1993 defining the criteria it will use to evaluate a PCB storage approval application (see 58 FR 59372-59374, modifying 40CFR761.65). EPA evaluates commercial storage applications on a case-by-case basis, including the environmental compliance history of the applicant. B. Other Regulations Governing PCB Releases PCB releases are regulated to some extent under the major environmental statutes. However, these regulations are not the primary driving force shaping decisions about how fast to dispose ofPCBs. Clean Air Act. PCBs are considered Hazardous Air Pollutants (HAPs) under the Clean Air Act. EPA will be promulgating a new category of regulation, known as maximum achievable control technology (MACT standards) for "major source" facilities in any listed source category. Major sources are defined as those sources that release 10 tons per year of any HAP, or 25 tons per year in total HAP emissions. EPA must also list, by 1995, die source categories that account for at least 90 percent of aggregate emissions for seven pollutants, including PCBs. These sources will be subject to MACT standards within ten years. Clean Water Act: The ambient water quality criteria for PCBs in surface waters is 0.001 ptg/1. Section 129 of the Clean Water Act specifically bans the discharge ofPCBs from PCB, electric transformer, and electric capacitor manufacturers. Facilities may apply to EPA or a state director for an adjustment of their PCB effluent limits if the PCBs in their effluent result from PCBs present in intake water. The facility owner or operator must show that the facility wastewater does not contain a higher PCB concentration than the intake water. (40CFR129.05) TRI: PCB releases are reported under the Toxic Chemical Release Inventoiy (TRI). All PCB releases reported in TRI were offsite transfers. Table 6 shows the trends in PCB disposal reported in TRI. Page 20 Ross & Associates Environmental Consulting, Ltd KG/YR Table 6 PCB Releases and Transfers, The Eight Great Lakes States Industries n 50 40 30 20 10 YEAH I MM* 1 1 POTW Land 3 Water 3 Air Honot Air Point TOTAL 1 1967 1.787.423 0 0 0. o 0 500 1.767.923 1998 1.769247 250 1 0 0 0 0 1.769.499 YEAR 1989 2.106.028 0 0 0 250 0 0 2.106.278 1990 1.447.135 0 0 0 0 0 5 1.447.140 1991 S83.S3B 0 0 0 0 0 0 583.538 Source: Toxic Chemical Release Inventory Data downloaded June 21,1994 1992 1.191293 0 1 0 0 0 0 1.191.094 Virtual E;` :nation Pilot Project PCB So,' . .s and Regulations RCRA: The interplay oetween TSCA and RCRA for PCB regulation is complex. In general, TSCA regulations apply to all aspects of PCB use and disposal. Because of this specific regulatory framework, RCRA's in-depth storage, treatment, and disposal rules generally do not apply to PCBs. Instead, RCRA regulations defer to TSCA requirements for PCB wastes. In some cases, however, RCRA regulations apply to PCBs. Following are some examples of the types of situations where RCRA regulations do apply to PCBs: Dielectric fluids and electric equipment with dielectric fluids treated under TSCA are not regulated under RCRA (40CFR 261.8); Municipal Solid Waste landfills must have in place programs that detect and prevent PCB disposal (40 CFR 258.20); Hazardous wastes containing liquid PCB wastes greater than 50 ppm are prohibited from land disposal unless approval is granted by petition. PCBs are a hazardous constituent under RCRA. As a result, the following RCRA regulations apply: groundwater monitoring (40CFR 264, App. IX); incineration requirements as aPOHC (40CFR 264, 347); and corrective action (40CFR 264.100). OSHA: The Occupational Safety and Health Act (OSHA) regulates workplace safety and sets permissible exposure levels for dangerous chemicals. The legal airborne permissible limit (PEL) for PCBs is 1 mg/m3 (42% chlorine) and .5 mg/m3 (54% chlorine) averaged over an 8-hour workshift The National Institute of Occupational Safety snd Health (NIOSH) recommends an airborne exposure limit of .001 mg/m3, averaged over a fc. .. nour period. These exposure limits pertain to air levels only. They do not apply to skin contact. Department of Transportation container requirements: DOT currently requires specialized containers for packaging and transporting liquid and non-liquid PCBs (49CFR178). TSCA allows larger containers for use in transporting PCBs if they are in compliance with OSHA flammable and combustible liquid rules (29CFR1910). EPA is reviewing these container requirements as part of the PCB disposal amendments (see Section VI). Page 22 Ross & Associates Environmental Consulting, Ltd Virtual Elimination Pilot Project PCB Sources and Regulations Department of Agriculture Regulations: PCB contamination of foodstocks may occur as the direct result of spills or leaks from PCB equipment, as well as indirectly from packaging contaminated with PCBs originating from recycled carbonless copy paper. The United States Department of Agriculture (USDA) regulates PCB contamination of food products by placing restrictions on food packaging operations and by setting tolerance levels for PCBs in certain foods. (21CFR109). New equipment or machinery for manufacturing food-packaging materials cannot contain or use PCBs. Equipment must be tested for PCBs and removed from use where they could contaminate food-packaging materials. Safe Drinking Water Act: Under the Safe Drinking Water Act, EPA established maximum contaminant levels for all public water systems in the United States. The MCL for PCBs is 0.0005 mg/1. CERCLA: Facilities must report disposal of PCBs in quantities greater than one pound to EPA for the purpose of tracking future liabilities. ( 102(a)) CERCLA also requires spills greater than 1 pound to be reported to the National Response Center. Ross & Associates Environmental Consulting, Ltd Page 23 Virtual Elimination Pilot Project PCB Sources and Regulations V. Non-Regulatory Programs Region 5 has developed an innovative, non-regulatory program designed to encourage more rapid and proper disposal of PCBs. Known as the PCB Phasedown program, it is designed to seek creative solutions cooperatively with the Region's utilities to remove PCB transformers and capacitors. For its early stages, the program is geared only toward "PCB-transformers," and PCB capacitor items with the highest concentrations of PCBs. All remaining regulatory phasedown deadlines for these items have already passed, and many transformers containing PCBs still have a useful life. The cost of decommissioning, removing, and disposing of a transformer containing PCBs may cost tens of thousands of dollars. The overall goal of the PCB Phasedown Program is to have all PCB electrical equipment in Region 5 decommissioned within five years. EPA has formed a partnership with the utilities in the Region to accomplish this goal. EPA is asking participating utilities to agree to a five year commitment to: Phasedown all PCB nameplated electrical equipment that has not already been removed from service; Test all non-nameplated electrical equipment in vaults, substations, and power plants, and phaseout any discovered to contain 500 ppm PCBs or greater; and Develop and implement an aggressive testing program for non-nameplated transformers and voltage regulators, and phaseout any found to contain 500 ppm PCBs or greater in sensitive areas such as agricultural lands, schools, hospitals, waterways and wetlands. Utilities participating in the program include: American Power & Light - Columbus, OH Centerior Energy - Independence, OH Commonwealth Edison - Chicago, IL Consumers Power - Jackson, MI Dayton Power & Light - Dayton, OH Detroit Edison - Detroit, MI Minnesota Power - Duluth, MN Page 24 Ross & Associates Environmental Consulting, Ltd Virtual Elimination Pitot Project PCB Sources and Regulations NIPSCO (Northern Indiana Public Service Company) - Hammond, IN Northern States Power - Minneapolis and Eau Claire, WI Ohio Edison - Akron, OH PSI Energy - Plainfield, IN Wisconsin Electric Power Company - Milwaukee, WI EPA is also seeking the utilities' help with outreach to other customers; influencing other users ofPCB electrical equipment to participate in the program; sharing technical expertise with smaller electricity suppliers; insuring that PCB electrical equipment at abandoned sites or buildings are included in the PCB phasedown program; and providing incentives to smaller utilities and industrial and commercial customers. EPA has requested that participating utilities submit a report showing their previous PCB disposal activities, remaining PCB items in service, and commitments for future disposal. Participating utilities report that they have already removed 87% of PCBs in service in electrical equipment through voluntary programs and regulatory requirements. They cited the following barriers to accelerated phaseout of PCB equipment: limited disposal options storage regulations (facility standards and time limits) enforcement penalties regulations on retrofilling transformers commercial storage regulations lack of economic incentives for decommissioning transformers liability for handling PCBs and PCB equipment generated by others EPA is exploring options that might reward more rapid disposal ofPCB equipment. Specifically, EPA is looking for options to build flexibility into enforcement actions for participating utilities. EPA will also prepare reports that discuss phasedown program efforts, and work to overcome perceived regulatory barriers that deter utilities from removing their PCB equipment. The phasedown program is still in the preliminary stages, however EPA is considering expanding it to other industrial sectors that may have large volumes of PCB transformers. Ross & Associates Environmental Consulting, Ltd Page 25 Virtual Elimination Pilot Project PCB Sources and Regulations VI. Potential Changes in PCB Regulation Several existing barriers in PCB regulations may be addressed in upcoming rulemakings. Most notable are the "disposal amendments" which illustrate EPA's self-reflection after two decades ofregulating PCBs. HPA has recognized the need to revisit certain aspects of existing regulations in order to provide the flexibility necessary to ensure proper disposal. In addition to the disposal amendments, EPA has proposed regulations that revise the criteria to reclassify transformers to lower regulatory levels. Both of these potential rule changes are summarized below. A. Disposal Amendments In June 1991, EPA announced an advance notice ofproposed rule making designed to restructure existing disposal regulations for PCBs. Several key tenets of PCB regulations may change significantly as a result of new disposal amendments. To date, the "disposal amendments" have not been issued, although they are anticipated to be released in proposed form by the end of 1994. Revised disposal rules could address changes in three areas: (1) Alternative disposal methods that do not pose an unreasonable risk of injury to human health and the environment; (2) Classes of PCBs and PCB Items that are not specifically regulated under existing requirements; and (3) Revised regulatory requirements for existing classes of PCBs and PCB items. In the Advance Notice of Proposed Rulemaking, EPA identified regulatory gaps in existing regulations, situations where implementation of existing regulations needed to be clarified, and situations where additional flexibility might promote disposal more effectively. Specifically, the disposal rules may address changes in the following areas: (I) Alternative storage and disposal methods: Large volume, non-liquid PCB wastes; Large volume PCB items; PCB wastes (PCB/Radioactive); Page 26 Ross & Associates Environmental Consulting, Ltd Virtual Elimination Pilot Project PCB Sources and Regulations (2) Classes of PCBs and PCB items not currently regulated under general disposal requirements: Household PCB waste Unknown or unauthorized uses of PCBs (3) Revised regulatory requirements for existing classes of PCBs Marking transport vehicles DOT containers for storage of PCB waste Definition of PCB transformer Drained PCB-contaminated transformers Temporary storage of PCB liquid <500ppm Sale of totally enclosed PCBs or PCB items PCB storage requirements Exclusion for labs providing PCB analytical samples Class exemption for EPA and NIST to process and/or distribute PCB standards in commerce 500 gallon exemption under PCB notification and manifesting rule Coordinated approach (state enhancement activities) Appendix F describes, in detail, the specific issues that will be addressed in this rulemaking. When the amendments are released, they may also include other revisions as well. The draft amendments are undergoing internal EPA review, and will likely be released in draft form before the end of the calendar year. Depending on the specific content of these regulations, several existing disposal barriers and loopholes may be eliminated. B. Transformer Reclassification Rules EPA has released a proposed electrical transformer reclassification rule that eases many requirements to reclassify PCB and PCB-contaminated transformers into a lower concentration category that avoids several regulatory requirements. Table 7 highlights the major changes proposed in the transformer reclassification rule. Appendix G describes these proposed changes in greater detail. Comments received on the proposed rule have included several proposed changes. EPA is currently reviewing the comments received on the draft rule to determine the next steps. Depending on the outcome of this review, the rule may be proposed again, or EPA may do additional studies, which would shift promulgation back for several months. Ross & Associates Environmental Consulting, Ltd. Page 27 Viitiiiil l liinitialirvii Pilot lYiiject PCII Homci'S mill ttrgulsitiniis Table 7: OVERVIEW OF PROPOSED CHANGES IN TRANSFORMER RECLASSIFICATION RULES Transformer Cateeorv Changes in oronosed rule < 50 ppm non-PCB transformers No change 50 - 500 ppm PCB-contaminated transformers Testing PCB concentration after retrofill eliminated under proposed rules Revised documentation under proposed rules 500 -1000 ppm PCB transformers Testing time decreased to 21 days from 90 days Temperature testing requirement eliminated PCB concentration requirement lowered to 25 ppm from 50 ppm to reclassify as a non-PCB transformer Revised documentation under proposed rules > 1000 ppm PCB transformers Ross it Associates Environmental Consulting, Ltd. Temperature testing requirement eliminated Revised documentation under proposed rules. 11WCBS XLW)0VERVIEW.X1J Otfll/M Virtual Elimination Pilot Project PCB Sources and Regulations Appendices Appendix A: PCB Use Tree Appendix B: PCB Activities / Uses Allowed Under TSCA Appendix C: Exemptions for Manufacturing, Processing, and Distribution Appendix D: Regulatory Framework for PCB Disposal Appendix E: Commercially Permitted PCB Disposal Companies Appendix F: Issues Considered in PCB Disposal Amendments Appendix G: Comparison of Transformer Reclassification Rules (Existing and Proposed) Appendix H: Data on PCB Releases Ross & Associates Environmental Consulting,; Ltd Appendix A: PCB Use Tree (prepared by the Lake Superior Work Group) The PCB use tree was developed by Shirley Thompson, a consultant workingfor the Ontario Ministry of Environment and Energy, on behalfofthe Lake Superior Workgroup. The use tree is part ofthe Binational Program to restore and protect the Lake Superior basin. virtiut Kiiinimiiioii pitot project Appendix B: PCB Activities/Uscs (Use and Release) Allowed Under TSCA PClt Sources si ml Regulations 11 v/ Activities/Uscs What is allowed Comments Transformers Railroad Transformers Mining Equipment Heat Transfer Systems Hydraulic Systems Carbonless Copy Paper Pigments : Electromagnets, switches, and voltage regulators Compressors, the liquid of natural gas pipelines Research and Development Microscopy mounting medium Use allowed for remainder of useful life. Specific requirements for different types of transformers: inspection; recordkeeping; location; registration; labeling; removing stored combustibles; disposal; notification. Use allowed: specific requirements for servicing transformers and reclassification; limits on allowable PCB concentration; last phaseout - 1986. Processing and distribution in commerce of PCBs for servicing mining equipment is permitted for persons with exemptions; requirements for servicing equipment, rebuilding machinery. Use allowed if PCB concentration is < 50 ppm; specific requirements for testing, retroflliing procedures and recordkeeping. Use allowed if PCB concentration < 50 ppm; specific requirements for testing, retroflliing procedures and recordkeeping. May be used in unenclosed manner indefinitely. Processing and distribution allowed with an exemption. Use allowed at any concentration; requirements for servicing, reclassification, inspection, storage of fluids (for repair) and recycling; restrictions on use near food or feed; prohibits servicing equipment with > 500 ppm PCBs, if work requires manipulation of internal components. Use allowed indefinitely at < 50 ppm, provided compressors and pipelines are marked. 3 classes: < 50 ppm; 50 ppm to 499 ppm; 500 ppm or >. When concentration < 50 ppm, no further testing is required. When concentration < 50 ppm, no further testing is required. Not used any more Use allowed indefinitely in small quantities; defined as PCBs originally packaged in one or more hermetically sealed container, volume < 5.0 ml and used only for scientific experimentation or analysis. Manufacture, processing and distribution in commerce permitted with exemption. Use allowed indefinitely. Manufacture, processing and distribution in commerce permitted with exemption. Ross Jt Associates Environmental Consulting. Ltd. lofS [168PCBSJXLW]IKE2XLS 09/11/94 Viiltml Klinimalion Pilot 'rojccl Appendix B: PCB Activities/Uses (Use and Release) Allowed Under TSCA PCII Sources urn! Regiilulloiis Activities/Uses What is allowed Comments Use in capacitors Use in and servicing of circuit breakers, reclosers and cable Microscopy Immersion Oil Optical Liquids Analytical Reference Samples Use allowed at any concentration; capacitors posing a risk to food or feed prohibited; location of capacitors confined to restricted-access substations or indoor installations. Use allowed at any concentration in these products; PCBs < 50 ppm may be used for servicing these items for the remainder of their useful lives; Use allowed indefinitely. Manufacture, processing and distribution in commerce permitted with exemption. Use allowed indefinitely. Manufacture, processing and distribution in commerce permitted with exemption. Analytical Reference samples derived from waste materials that contain PCBs; samples analyzed by laboratories that have procedures for handling PCBs. Added in 4/11/94 rule (59 FR 16991-16999) - EPA granted an exemption to a company to process and distribute analytical reference samples derived from waste materials containing PCBs in order to create "real world" reference samples. Such use must be specifically authorized by rule. * excluded PCB products * using PCBs from excluded or recycling process * applying sewage sludge < 50 ppm Subject to specific regulatory requirements. Rau & Axwciates EnvhvmnentiH Cimimllhig, Ltd. 2 of5 [16Sratfi.XUVfUSU7.JClS 09/l L 94 vimui I'hminaiion liiotl'mjod Appendix B: PCB Activities/Uses (Use iind Relense) Allowed Under TSCA I'CU Simri-es siiiiI Regulations 1' '' Activitics/Uscs What is allowed Comments Definition Concentration limits Detergent bars Air emissions Discharge to water Disposal Excluded manufacturing processes include the inadvertent release of PCBs to products, air, and water. The following conditions identify instances where inadvertent PCB generation is excluded from the regulations. * Concentration of PCBs in products leaving a manufacturing site or imported to the U.S. have an annual average of < 25 ppm, with a 50 ppm maximum. * PCB concentration in detergent bars from manufacturer or imported is less than 5 ppm. Release of PCBs at point at which emissions are vented to ambient air < 10 ppm. * Amount of PCBs added to water from discharge < 100 micrograms/resolvable gas chromatographic peak per liter of water discharged. * Disposal of process wastes above 50 ppm in accordance with TSCA disposal rules. Excluded PCB Products (40 CFR 761.3) Excluded PCB products are PCB materials with concentrations < 50 ppm, including but not limited to: Process by-products Non-Aroclor inadvertently generated PCBs as a by-product or impurity from a chemical manufacturing process. Historic Uses Products contaminated with PCBs from historic uses. Recycled Fluids Recycled fluids and/or equipment contaminated during use involving products described in the previous two examples. Used Oils Used oils containing <50 ppm, and legally manufactured, processed, distributed in commerce, or used before 10/1/84. PCB concentration cannot be below 50 ppm due to dilution via leaks or spills of PCBs > 50 ppm. Note: Products or sources of PCBs in waste oils must have been manufactured, processed, distributed in commerce, or used, pursuant to EPA regulatory authority, exemption petition, settlement agreement, or other agency programs. Small Capacitors - light ballasts No disposal restrictions unless capacitor is leaking. Note: General prohibition on waste oil with PCBs. If leaking, incinerate Ross & Associates Environmental Consulting, Ltd. Jo/S [l 6RPCBSJCLWIUSEZJCLS 09/11/94 Viilual I?.liinitiation Pilot Project Appendix B: PCB Aetivities/Uses (Use and Release) Allowed Under TSCA PCI! Sources mill Itcgiilntiiins Activitics/Uscs What is allowed Comments Individual and Company Exemptions Renewal ofIndividual and Company Exemptions Class Exemptions (Research and Development) (Non-porous transformers) Renewal ofResearch and Development Class Exemption One year exemption granted to sped!: ally identified companies for designated activities: Processing and distributing in commerce PCBs for the following uses or activities: Mounting medium in microscopy Immersion oil in low fluorescence microscopy Optical liquids Exporting PCBs for use in small quantities for research and development Importing (manufacture) into the U.S. smalt quantities of existing PCB fluids from electrical equipment for analysis. Manufacturing PCBs for use in small quantities for research and development. Processing and exporting small quantities of PCBs for research and development. One-year exemptions for all individual companies renewed automatically unless a petitioning company notifies EPA of (1) increased PCB amounts to be processed, distributed, imported, or exported, and (2) any changes in activity. Unless EPA initiates rulemaking to terminate the exemption or acts on the petition, petitioner is allowed to continue activities under exemption. * Class exer un to all processors and distributors of PCBs in small quantities for research and development, provided they meet recordkeeping and reporting conditions. One-year class exemption granted to members of the Electrical Apparatus Service Association with the following allowances: Hie exempted may process and distribute in commerce non-porous transformer component parts that have been decontaminated of PCB residues. Members may buy and sell certain types of PCB or PCB-Conlaminated Transformers. No provision for renewal. . * Research and development class exemption is renewed automatically, unless EPA finds that the activities of any individual or company poses an unreasonable risk of injury to health or the environment. * EPA evaluates the information, issues proposed rules affecting the class exemption or individuals included in the exemption. Until final rule is issued, processing and distributing PCBs for research and development could continue. ' Note different standard required to discontinue automatic renewal. /(o.tJiC Aftocialet Environmental Consulting, Ltd 4 o/3 (16SPCBSJCLW}USEZJCLS 00/11/94 Virtual Klimination Pilot Project Appendix B: PCB Activities/Uses (Use and Release) Allowed Under TSCA l'Cli Sources mid Regulations Activities/Uscs What Is allowed Comments Renewals for Exemptions granted after 4/25.94 Must submit certified letter to EPA at least 6 months prior to expiration of current exemption, stating that specific types of activities (e.g., procedures for handling PCBs, amount handled, and any other activities listed in original exemption) have not changed. Any changes considered require a new petition submittal. Change made in final rule issued 4/11/94 (59 FR 16991-16999) Paper products/asphalt roofing Air emissions Discharge to Water Disposal Recycled PCBs are those PCBs that appear in the processing of paper products or asphalt roofing materials from PCB-Contaminated raw materials. * Processes that recycle PCBs must meet the following requirements: Asphalt roofing products leaving processing sites must not have detectable PCB concentration levels. * Paper products leaving manufacturing sites, or in imported paper, products are required to have an annual average < 25 ppm, with a 50 ppm maximum. Emissions of PCBs to ambient air must be less than 10 ppm. The amount of Aroclor PCBs added to water discharges from asphalt roofing processing sites and the processing ofpaper products is restricted. * Disposal of any other process wastes with PCBs > 50 ppm falls under storage and disposal rules. (Subpart D) The DISTRIBUTION IN COMMERCE of the intact, non-leaking electrical equipment listed below constitute "totally enclosed activities." transformers (including transformers used in railway locomotives and self-propelled cars) capacitors electromagnets voltage regulators switches (including sectionalizers and motor starters) circuit breakers reclosers cable equipment containing non-leaking PCB capacitors Ros.i if Associates Environmental Consulting. Ltd. So/S [16SPCBSJCLWJUSEZJCLS 09/11/94 Appendix C: PCB Exemptions for Manufacturing, Processing and Distribution in Commerce 40 CFR 761.80, July 1993 Note: EPA has granted thefollowing 1 year exemptionsfor PCB activities in 40 CFR 761.80, July 1993. Company . Exemption (allowed activities) Comments/conditions Me Crone Accessories Components Processing and distribution in commerce for use as a Chicago, IL _____________ ____ ______ mounting medium in microscopy R.P. Cargillc Laboratories, Inc. ' Processing and distribution in commerce for use as a Cedar Grove, NJ mounting medium in microscopy, and immersion oil in ______________ ________ low fluorescence microscopy and an optical liquid_________________________________________________________ Accu-Standnrd Exportation of PCBs for use in small quantities for New Haven, CT research and development Unison Transformer Services importation (manufacture) into the U.S., small quantities Samples must be shipped in 5.0 ml or less, in Tarrytown, NY of existing PCB fluids from electrical equipment for hermetically sealed vials analysis * Exemption is limited to no more than 250 total samples per year Unison must make quarterly inspections of laboratories to ensure safety procedures are followed Unison must annually notify and describe to EPA its attempts to have samples analyzed abroad California Bionuclear Corp. Manufacture PCBs for use in small quantities for Sun Valley, CA _ research and development ' Foxboro Co. North Haven, CT ULTRA-Scientific, Inc. Hope, R.I Midwest Research Institute Kansas City, MO Pathfinder Laboratories St. Louis, MO Radian Corp. Austin, TX Wellington Sciences USA College Station, TX ' Accu-Standard New Haven, CT_______________________________________________ _________________ ; EXEMPIXLS 09/11/94 Appendix C: PCB Exemptions for Manufacturing, Processing and Distribution in Commerce 40 CFR 761.80, July 1993 Note: EPA has granted thefollowing I year exemptionsfor PCB activities in 40 CFR 761.80, July 1993. Class Exemption Exemption (allowed activities) '____________ A class exemption is granted to all processors and distributors of PCBs in smalt quantities for research and maintain records of their PCB activities development, subject to specific conditions. for a period of 5 years Any person or company which expects to process or distribute in commerce 100 ir more PCBs in 1 year must report to EPA, identifying sites of activities and quantity of PCBs to processed or distributed in commerce Tire one year class exemption will be renewed automatically unless information is submitted affecting EPA's concludes that there is an unreasonable risk of injury to health or the environment from the activity of the exempted party. Electrical Apparatus Service Association St. Louis, MO (class exemption to members) Processing and distribution in commerce of non-porous transformer component parts which have been decontaminated of PCB residues; buying and selling PCB Transformers or PCB-Contaminated Transformers to which only double-rinsed non-porous component p; * have been added. Chcm Service, Inc. West Chester, PA Processing and exportation of small quantities of PCBs for research and development Foxboro Co. North Haven, CT PolyScicncc Corp. Niles, IL ULTRA-Scicntific Hope, RI Supdco, Inc. Bellefonte, PA Radian Corp. Austin, TX . These 1 year exemptions renew automatically, subject to provisions described in 40 CFR 761.80(h). Petitions approved after April 1994 will no longer renew automatically. EXEMPTMS Virtual Elimination Pilol Vojed 1'CIJ Sources ami Regulations Appendix D: Regulatory Framework for PCB Disposal 'SCA Regulations require specified disposal methods for each type of PCB item. Itructure: Pollutant form determines the type of disposal options available. )isposal options are: (1) incineration in regulated PCB incinerator; (2) disposal at licensed chemical waste landfill; (3) disposal in a high efficiency boiler; (4) alternative method (subject to EPA approval); (5) disposal as municipal solid waste; (6) no restrictions (unregulated disposal of PCB items). REQUIREMENT PCB ITEM* ncineration only PCBs >50ppm, except mineral oil dielectric fluid, liquids 50-500ppm, and non-liquid PCBs>50ppm. (The exceptions have separate disposal requirements) Liquids from PCB transformers > 500 ppm PCB capacitors > 500 ppm owned by person who manufactured PCB capacitors or equipment; also applies if PCB capacitors were acquired during manufacturing. ncineration or chemical vaste landfill only non-liquid PCBs>50ppm (contaminated soil, rags, other debris) PCB transformer carcasses (PCBs > 500 ppm) before draining require incineration; after draining, may be sent to landfill. PCB-Contaminated Electrical Equipment (50-500 ppm capacitors); after draining, may be sent to landfill. PCB articles > 500 ppm before draining require incineration; after draining, may be sent to landfill. PCB containers > 500 ppm before draining require incineration; after draining, may be sent to landfill. Alternative disposal nethods includes high efficiency toilers subject to EPA approval; onditions for approval vary iy pollution form) Disposal as Municipal Solid Waste allowed mineral oil dielectric fluid from PCB-Contaminated electrical equipment (50-500ppm) liquids, other than mineral oil dielectric fluid (50-500ppm) dredged materials and municipal sewage treatment sludges > 50ppm, if required disposal methods are proved unreasonable drained electrical equipment is unregulated; liquid must be disposed of properly small non-leaking capacitors (fluorescent light ballasts), hydraulic machines < 500 ppm PCB if drained. PCB containers, if concentration < 500 ppm PCB hydraulic machines may be disposed of as MUNICIPAL SOLID WASTE if drained (if > 1000 ppm, flushed). Liquids must be disposed of appropriately. Unregulated PCB-Contaminated electrical equipment (50-500 ppm) except capacitors is unregulated, if liquid is disposed of properly. PCB articles (50-500 ppm) are unregulated if drained. Ross & Associates Environmental Consulting, Ltd. 114BPCBS.XLWjPCBDt3P.XU M/tlflM APPENDIX E COMMERCIALLY PERMITTED PCB DISPOSAL COMPANIES The following companies are permitted to operate different types of PCB disposal facilities (as of June 30, 1993): INCINERATOR Aptus, Inc. Chemical Waste Management Rollins Weston ALTERNATE THERMAL General Electric Ogden Environmental Services, Inc. O.H. Materials Corporation CHEMICAL Chemical Waste Management Exceltech, Inc. General Electric Aptus, Inc. PPM, Inc. ENSR Operations Transformer Consultants Trinity Chemical Co. Inc. PHYSICAL SEPARATION CECOS International Process Center ENSCO Aptus, Inc. Unison Transformer Services, Inc. Quadrex HPS, Inc. General Electric S.D. Myers, Inc. PIPELINE REMOVAL Texas Eastern Gas Pipeline Company Atguonguin Gas Transmission Company Chemical Processors, Inc. Columbia Gas Transmission Corp. Columbia Gulf Transmission Co. Tennessee Gas Pipeline Company (Tenneco) PCB TRANSFORMER DECOMMISSIONING fDlsassemblv/Smelting) Aptus, Inc. Environmental International Electric Services/Unison Transformer Consultants Unison CHEMICAL WASTE LANDFILLS Chemical Waste Management Chem-Security Systems Incorporated Envirosafe Services Inc. of Idaho CWM Chemical Services Control, Inc. U.S. Ecology, Inc. U.S. Pollution Control, Inc. BIOLOGICAL Detox Industries, Inc, Virtual [Elimination Pilot Project PCI) Sources iitul Regulations Appendix F: Issues Considered in PCB Disposal Amendments Change under consideration Large Volume, PCB Wastes (e.g., wastes from automobile shredding, white goods and industrial scrap, soils, sludges, and sediments) Under current regulations, these materials may be disposed of by incineration, in a chemical waste landfill, or by approved alternative method of destruction Additional disposal methods that do not present unreasonable risk of injury to human health or the environment Large Volume PCB Items (e.g., natural gas pipelines, natural gas ventilation systems, air compressor systems) - Comparatively large surface areas contaminated w/comparatively small quantities of PCBs Items must be disposed of in chemical waste landfill if item not decontaminated under alternative disposal technology permit -- may not be the best use of limited chemical waste landfill space * Additional disposal methods * Methods of decontaminating large volume PCB items Smelting of PCB-contaminated electrical equipment allowed because disposal of drained equipment unregulated Should EPA regulate disposal of these items, including whether such regulation is necessary to prevent unreasonable risk of injury to health or the environment PCB Radioactive Wastes Continued use, storage and disposal of mixtures, items, and wastes with PCB and radioactive constituents may not be coordinated with other Federal statutory or regulatory requirements Note: This table summarizes the issues described in EPA's advance notice of proposed rulemaking regarding disposal of PCBs. 56 FR 26738 - 26744, June 10, 1991. * How to develop criteria for authorization of continued use, storage and disposal of such materials to minimize risks to human health and the environment D1SPAMENXLS, 09/11/94 Appendix F: Issues Considered in PCB Disposal Amendments (2) Issues not Originally Contemplated When TSCA Rules Promulgated Household PCB waste (e.g., PCBs in household paint) * Household wastes must be separated (e.g, regulated from unregulated wastes); unregulated waste must be manifested and moved to storage or disposal facility w/in 10 days, subject to 1-yr storage requirement * Should EPA exclude PCB household waste under TSCA, e.g., using similar criteria to RCRA household waste exemption (distinguish commercial storage activities from collection programs; household wastes would be unregulated) Unknown or unauthorized uses of PCBs Several widespread PCB applications not considered when original regulations developed (e.g., PCB contamination in HVAC gaskets, and gaskets and felt sound-dampening materials in marine applications) Seeking information on other locations where PCBs have been identified where use is not authorized under current regulations Marking Transport Vehicles Duplication in existing regulating regarding marking a transport vehicle when it is loaded with PCB containers that contain more than 45kg of liquid PCBs >50ppm (40CFR761.40(b) and (e) How to remedy duplication: delete one of the sections, or delete both and rewrite requirement Note: This table summarizes the issues described in EPA's advance notice of proposed rulemaking regarding disposal of PCBs. 56 FR 26738 - 26744, June 10, 1991. Ross < Associates Environmental Consulting. Ltd Page 2 of6 DISPAMENJCLS. 09/11/94 Viilttsil Elimination Pilot Project PCII Sources inn! Regulations DOT Containers for Storage of PCB Waste Appendix F: Issues Considered in PCB Disposal Amendments _______________ Issue / barrier / gap Current EPA requirements (design specs) for PCB containers may be unnecessarily stringent given the physical and chemical properties of PCBs. Change under consideration ;; Appropriate situations to defer to DOT requirements regarding the types of packaging us transport or store PCB waste. EPA regulations prohibit temporary storage of mixed radioactive/PCB wastes in non-DOT containers (40 CFR761.60(b)(2)(vi), 761.65(c)(6)); In some cases of temporary storage, DOT containers may be inappropriate due to limited access. ; Definition of a PCB Transformer PCB transformers may have manufacturers' name plate and other identifying information removed to avoid expense of proper disposal (40 CFR 761.3). Amend the regulatory language defining PCB transformers to clarify EPA policy, The definition of "PCB-Contaminated Electrical Amend the language of the PCB electrical Equipment" has been confusing for the regulated equipment definition, community (40 CFR 761.3) (mineral oil vs. "oil-filled") Drained PCB-Contaminated Transformers The disposal of drained PCB-Contaminated electrical equipment is unregulated (smelting of transformer carcasses for recycling constitutes disposal). EPA has received anecdotal information that exposure from drained equipment may be significant. (40 CFR 761.60(b)(4), 761.60(a)(2) or (3) Restrict the disposal of drained pieces of electrical equipment to ensure they are not illegally re-used. Note: This table summarizes the issues described in EPA's advance notice of proposed rulemaking regarding disposal of PCBs. 56 FR 26738-26744, June 10, 1991. Itoss <5 Associates Environmental Consulting, Ltd. Pago 3 of 6 DISPAMENJCLS, 09/11/94 Virtual Elimination I'ilol Project 1'L'H Sources mid Itegulatlons Temporary Storage of PCB Liquid <500ppm Sale of Totally Enclosed PCBs or PCB Items Spill Cleanup Policy Appendix F: Issues Considered in PCB Disposal Amendments Temporary storage is not allowed for liquid PCB waste greater than 500 ppm (761 65(c)). However, other sections allow "processing and distribution" in commerce of PCBs > 50 ppm for purposes of disposal. . Change under consideration Clarify activities considered "processing for disposal" or allow temporary storage of liquid PCB waste > 500 ppm. No recordkeeping is required for the sale of totally enclosed PCB transformers and large PCB capacitors (40 CFR-761.20). EPA is attempting to limit the illegal disposal of these units by parties claiming their equipment has been sold, when illegal disposal has occLired instead.. Establish recordkeeping requirements for such items. Current regulations do not reflect new CERCLA reportable quantities. (40 CFR 761.125) Amend TSCA language to be consistent with CERCLA (PCB spills of 1 lb, or more reported to the National Response Center). Spill Cleanup Policy has been applied to some spills inappropriately. (40 CFR 761.120) Coordination of PCB spill cleanups with the requirements of other federal statutes. Clarify EPA policy -'at spill clean up policy only addresses recent spills. Note: This table summarizes the issues described in EPA's advance notice of proposed rulemaking rega* ding disposal of PCBs. 56 FR 26738 - 26744, June 10, 1991. DISPAMENJCLS. 09/!1/94 Virtual [''liminnlMm Pilot Vojcct PCD Sources mill Keguhilions Appendix F: Issues Considered in PCB Disposal Amendments PCB Storage Requirements 1) Indefinite Storage of articles designated for reuse Current regulations limit the amount of time PCB articles or containers may be stored for DISPOSAL, but no regulations limit the length of time an article may be stored for REUSE * PCB- and PCB-contaminated transformers have been held "in storage" well beyond a reasonable time for reuse Change under consideration Options to clarify that items may not be placed in storage for an indefinite period of time under the pretense that they are "in use" -- e.g., labeling articles when placed in storage for limiting reuse storage time. Should EPA place limitations on the time allowed for storage for reuse or develop a more flexible approach such as a "reuse or reclassification schedule" on a case-specific basis 2) Clarification of 1-year storage for disposal requirement Confusion exists as to WHEN the 1-year disposal clock begins -- whether it is the date it is placed into storage, or the date it is designated for disposal. The intent of regulation is to ensure disposal 1 year from the data the item is removed from service Amend language 761.65(a) to make explicit that the "storage for disposal" clock starts when the item is removed from service, even if it is not placed into storage until a later date 3) Situations that warrant an extension of the 1-year storage for disposal requirement Long-term biological destruction processes and the absence of adequate capacity for disposal of mixed wastes are instances where the one-year storage requirement may need to be suspended. Temporarily suspend one-year storage limits for certain situations, or extend time limit at the beginning of the storage period. Allow for renewal of extensions if requirements are met. Note: This table summarizes the issues described in EPA's advance notice of proposed rulemaking regarding disposal of PCBs. 56 FR 26738 - 26744, June 10, 1991. Ross it Associates Environmental Consulting, Ltd. Page 5 of 6 D1SPAMENJCLS, 09/11/94 . . [ riliminalion Pilot Project PC!! Sources uml Uc^iiliilions Appendix F: Issues Considered in PCB Disposal Amendments Exclusion for labs providing PCB analytical samples Laboratories involved in routine quality assurance measures may be subject to the restrictions on distribution of PCBs. ________ Change tinder consideration Exempt labs participating in multi-laboratory studies from PCB distribution restrictions if PCBs are used for analysis; impose restrictions on activities, including notification requirement Class exemption for EPA and NIST to process and/or distribute PCB Standards in commerce Confusion exists as to whether or not EPA and the National Institute for Standards and Testing need an exemption to distribute PCB materials and audit samples. Clarify regulations to state that exemption or authorization not required. 500 gallon exemption under the PCB notification and manifesting rule. Facilities that store less than 500 gallons of "liquid" PCB waste are not required to seek approval as a commercial storer may need to establish a similar exemption for non-liquid PCB waste (40 CFR 761.3). Establish a small quantity exemption for non-liquid PCB waste to complement notification and manifest regulation's small quantity exemption for liquids. State enhancement activities There is no formal federal recognition of state-issued PCB storage and disposal permits. The regulated community must obtain both state and federal permits. (40 CFR 761.60, 761.65, and 761.70) Allow federal recognition of state PCB storage and disposal permits to eliminate concurrent state and federal permitting where possible; encourage states to list PCBs under their RCRA programs by making resources available through grant programs. Note: This table summarizes the issues described in EPA's advance notice of proposed rulemaking regarding disposal of PCBs. 56 FR 26738 - 26744. June 10, 1991. Pots Associates Environmental Consulting. Ltd Page 6 oP 6 DISPAMENJCLS, 09/11/94 Appendix G: Comparison of Transformer Reclassification Rules-Existing and Proposed Transformer Category EXISTING Rules <50 ppm Non-PCB Transformers No reclassification required 50 to < 500 ppm PCB-Contaminated Transformers Actions Drain, refill and/or service transformer. Installer records concentrations, retrofill schedules. Testing Requirements Threshold for Reclassification Test 3 months after installation (in-service) Raise temperature of the fluid to 50 C during test. After testing, PCB concentration is: < 50 ppm: reclassify as non-PCB transformer 50 - 5Q0ppm: PCB contaminated transformer 500 to < 1000 ppm PCB Transformers Actions Testing Requirements Threshold for Reclassification Drain, refill and/or service transformer. Installer records concentrations, retrofill schedules. Test 00 days after installation (in-service) Raise temperature of the fluid to 50 C during test. After testing, PCB concentration is: < 50 ppm: reclassify as non-PCB transformer 50 - 500ppm: PCB contaminated transformer >500ppm: repeat process until concentration is below 500ppm >1000 ppm PCB Transformers Actions Testing Requirements Tlireshold for Reclassification Drain, refill and/or service transformer. Installer records concentrations, retrofill schedules. Test 90 days after installation (in-service) Raise temperature of the fluid 50 C during test. After testing, PCB concentration is: < 50 ppm: reclassify as non-PCB transformer 50 - 500ppm: PCB contaminated transformer >500ppm: repeat process until concentration is below 500ppm PROPOSED Rules No reclassification required Highlights No change Drain, flush, and refill transformer Facilities record sample results, retrofill schedules. No testing required Not required to reach 50 degrees Celsius After retrofill: Drained and flushed transformer may be reclassified immediately as a non-PCB transformer No further testing required. Drain, flush, and refill transformer Facilities record sample results, retrofill schedules. Test after 21 days No 50 degree Celsius temperature requirement After retrofill, PCB concentration is: < 25 ppm: reclassify as non-PCB transformer 25 - 500 ppm: reclassify as PCB - contaminated transformer or retest alter 90 days >500ppm: retrofill may be repeated following same procedures * Testing requirement eliminated under proposed rules. Revised recordkeeping under proposed rules. Testing time decreases from 90 to 21 days. Temperature requirement eliminated. PCB reclassification thresholds have been altered. Revised recordkeeping under proposed rules. Drain, flush, and refill transformer. Place unit in service. Record samples, retrofill schedule. Test 90 days after installation (in-service) After, retrofill PCB concentration is: < 50 ppm: reclassify as non-PCB transformer 50 - 500ppm: PCB contaminated transformer >500ppm: retrofill may be repeated following same procedures * Very few changes Eliminate temperature requirement Revised recordkeeping under proposed rules. Ross it- Associates Environmental Consulting, Ltd f168PCBSJCLWJRECUSS2MS 09/11/94 Appendix H: Data on PCB Releases Virtual Elimination Pilot Project PCB Sources and Regulations Appendix H contains information on PCB releases available from several federal and state reporting systems. Federal and state agencies collect information on PCB releases as part of broader programs designed to meet reporting requirements for multiple substances. It is important to keep in mind that each data set must be interpreted separately due to differences in reporting requirements and the types of information collected. All data is organized by Standard Industrial Classification codes (SIC codes). This structure offers a uniform method to identify industrial sectors. The first two digits of a SIC code identify major industrial sectors. The full four digit code allows more specific identification of industry type. Even with this detailed breakdown, variation exists within a given SIC code. For a complete list and description of SIC codes, as well as the specific industrial processes covered by each code, refer to the Standard Industrial Classification Manual. By using SIC codes, it is possible, on a broad scale, to identify the types of industrial sectors where PCB releases occur most frequently. Appendix H includes PCB release information from five specific data sources. The list below indicates the specific components of Appendix H. The first page of each set of data includes an explanation of the reporting program and the data reviewed. App. HI App. H2 App. H3 Summary of Reporting Information: The table shows, by SIC code, the frequency with which PCB releases appear in each data set reviewed for this analysis. It is organized by SIC code and by state. Toxic Chemical Release Inventory (TRI) data: TRI data for 1992 and 1991. H2a = 1992 data for Great Lakes states only H2b = 1991 data for Great Lakes states only Permit Compliance System (PCS) data: PCS data for the Great Lakes basin (facilities located in the Great Lakes basin only; not necessarily statewide) H3a = July 1992 - June 1993 data H3b = July 1991 - June 1992 data (cont'd) Ross & Associates Environmental Consulting, Ltd Virtual Elimination Pilot Project PCB Sources and Regulations App. H4 App. H5 App. H6 Wisconsin Air Point Source data: PCB air emissions data collected for Wisconsin's Clean Air Act Title V Operating Permit Program (reported data). Michigan Critical Materials Registry: 1991 data collected under Michigan's wastewater reporting program. Data indicates the number of facilities reporting PCB use (including material on-site). Notification and Manifesting data Ross & Associates Environmental Consulting, Ltd. Virtual Elimination Pilot Project PCB Sources mid Regulations Appendix HI: Summary of PCB Reporting Data SIC Category 10 14 20 24 25 SIC Code Metal Mining 1011 Iron Ores 1021 Copper Ores 1081 Metal Mining Services Nonmetallic Minerals, Except Fuels 1422 Crushed And Broken Limestone 1440 Sand and Gravel Food and Kindred Products 2050 Bakery Products 2063 Beet Sugar 2087 Flavoring Extracts And Syrups, Nec Lumber and Wood Products 2493 Reconstituted Wood Products Furniture and Fixtures 2500 Furniture and Fixtures 2522 Office Furniture, Except Wood 2591 Drapery Hardware and Blinds and Shades To tal IL IN MI mi PCS mi PCS nti PCS TRI PCS MI 1 1 1 4 2 1 3 1 2 7 3 1 MN N Y OH PA WI TRI PCS TRI PCS TRI PCS TRI PCS TRI PCS H NOTE: This table compares the number.of facilities in each SIC code that report mercury, releases under the: different federal reporting programs discussed in this report Tlie data is the most current available for each program. This table illustrates how the number of facilities reporting.RGB releases varies based on the reporting requirements and tliresholds of each reporting program. KEY: TRI = Toxic Chemical Release Inventory, 1992 data PCS = Permit Compliance System* July 1992 - June 1993 data : MI = Michigan Critical Materials Wastewater Report, 1991 data;: WI = Wisconsin Title V Operating Permits Program, 1991 data : SUMMPCH.XLS 1 of6 09/ii m Virtual Hfinimalum Pilot Project rc: Sources and Regulations Appendix HI: Summary of PCB Reporting Data SIC Category 26 27 28 29 SIC Code Paper and Allied Products 2600 Paper and Allied Products 2611 Pulp Mills 2621 Paper Mills 2631 Paperboard Mills 2640 Not Listed 2650 Paperboard Containers and Boxes 2651 Not listed 2670 Misc. Convened Paper Products 2679 Converted Paper Products, Nec Printing and Publishing 2700 Printing and Publishing 2710 Newspapers 2750 Commercial Printing 2782 Blankbooks and Looseleaf Binders 2790 Printing Trade Services Chemicals and Allied Products 2800 Chemicals and Allied Products 2810 Industrial Inorganic Chemicals 2813 Industrial Gases 2819 Industrial InoTganic Chemicals, Nec 2820 Plastics Materials and Synthetics 2830 Drugs 2840 Soap, Cleaners, and Toilet Goods 2850 Paints and Allied Products 2851 Paints And Allied Products 2860 Industrial Organic Chemicals 2865 Cyclic Crudes And Intermediates 2870 Agricultural Chemicals 2890 Miscellaneous Chemical Products 2891 Adhesives And Sealants 2899 Chemical Preparations, Nec Petroleum and Coal Products 2900 Petroleum and Coal Products Total IL IN Ml MN NY OH PA WI TRI PCS TR1 PCS m PCS TRI PCS M TRI PCS TRI PCS TRI PCS TRI PCS TRI PCS H 2 4 1 13 6 1 l 1 1 4 1 1 . 1 1 3 2 1 1 2 2 1 l 2 4 1 2 2 4 2 1 2 2 13 1 l SUMMPCBJCLS 2 of6 09/11/94 Virtual Ktiminnlton Pilot Project PCU Sources iiml Regulations Appendix HI: Summary of PCB Reporting Data SIC Category 30 32 33 SIC Code 2911 Petroleum Refining Rubber and Miscellaneous Plastic Products 3053 3069 3079 3080 Gaskets, Packing and Sealing Devices Fabricated Rubber Products, Nec Miscellaneous Plastics Products, NEC Stone, Clay, and Glass Products 3220 3221 3241 3273 3274 3290 3295 3297 Glass and Glassware, Pressed or Blown Glass Containers Cenient, Hydraulic Ready-Mixed Concrete Lime Misc. Nonmetallic Mineral Products Minerals, Ground or Treated Nonclay Refractories Primary Metal Industries 3312 Blast Furnaces And Steel Mills 3313 Electrometallurgical Products 3316 Cold Finishing Of Steel Shapes 3317 Steel Pipe And Tubes 3320 Iron and Steel Foundries 3321 Gray And Ductile Iron Foundries 3322 Malleable Iron Foundries 3334 Primary Aluminum 3339 Primary Nonferrous Metals, NEC 3340 Secondary Nonferrous Metals 3341 Secondary Nonferrous Metals 3354 Aluminum Extruded Products 3360 Nonferrous Foundries (Castings) 3365 Aluminum Foundries 3366 Copper Foundries 3369 Nonferrous Foundries, NEC 3398 Metal Heat Treating Total IJ IM MI MN NY OH PA WI TRI pcs TRI PCS TRI PCS TRI PCS MI TRI PCS TRI PCS TRI PCS TRI PCS TRI PCS W l 21 1 3 4 11 -- 3 1 1 15 1 .1 1 1 5 2 1 1 2 2 1 6 1 5 1 1 2 10 2 1 4 1 1 1 1 2 1 6 1 2 1 SUMMPCB.XLS 3 of6 09/1!m Viilniil Klimmution Pilot Project I'f 'll Sources mill Rrguhiiiuiis Appendix III: Summary of PCB Reporting Data SIC ategory 34 35 36 37 SIC Code Fabricated Metal Products 3400 Fabricated Metal Products 3442 Meta] Doors, Sash, and Trim 3443 Fabricated Plate Work (Boiler Shops) 3449 Miscellaneous Metal Work 3460 Metal Forgings and Stampings 3462 Iron and Steel Forgings 3463 Automotive Stampings 3471 Plating And Polishing 3479 Metal Coating And Allied Services 3490 Misci Fabricated Metal Products 3499 Fabricated Metal Products, Nec Industrial Machinery and Equipment 3510 Engines and Turbines 3519 Internal combustion engines, Nec 3530 Construction and Related Machinery 3540 Metalworking Machinery 3544 Special Dies, Tooh Mgs, and Fixture 3545 Machine Tool Accessories 3550 Special Industry Machinery 3566 Speed Changers, Drives, and Gears 3570 Computer and Office Equipment 3580 Refrigeration and Service Machinery 3585 Refrigeration And Heating Equipment 3590 Industrial Machinery, NEC Electronic and Other Electronic Equipment 3612 3620 3621 3630 3651 Transformers, Except Electronic Electrical Industrial Apparatus Motors And Generators Household Appliances Household Audio and Video Equipment Transportation Equipment 3710 Motor Vehicles and Equipment 3711 Motor Vehicles And Car Bodies Total IL IN Ml MN NY OH PA WI TRI PCS TRI PCS TRI PCS TRI PCS jV a TRI PCS TRI PCS TRI PCS TRI PCS TRI PCS If iTi 1 5 1 1 1 6 13 4 1 9 1 5 2 1 1 1 3 1 1 1 1 - 1 11 1 111 1 1 3 15 SUMMPCB.XLS 4 of 09/! 1/94 Virtual Elimination Pilot Project PCIJ Sources and Regulations Appendix HI: Summary of PCB Reporting Data SIC Category 38 39 42 47 49 SIC Code 3714 Motor Vehicle Parts And Accessories 3790 Miscellaneous Transportation Equipment Instruments and Related Products 3812 Search And Navigation Equipment 3840 Medical Instruments and Supplies 3843 Dental Equipment and Supplies Miscellaneous Manufacturing Industries 3940 Toys and Spoiling Goods 3970 Not listed 3990 Miscellaneous Manufactures Trucking and Warehousing 4230 Trucking Terminal Facilities Transportation Services 4785 Inspection and Fixed Facilities Electric, Gas, and Sanitary Services 4911 Electric Services 4952 Sewerage Systems 4953 Refuse Systems Total IL IN MI MN NV OH PA WI TRI PCS TR1 PCS TRI PCS TRI PCS MI TRI PCS TRI PCS TRI PCS TRI PCS TRI PCS W 2 1 1 46 1 1 1 1 1-- 1 1 1 1 1 21 14 16 1 2 lilt 1 5 50 Wholesale Trade - Durable Goods 5013 Motor Vehicle Supplies and New Parts Wholesale Trade 65 Real Estate 6512 Nonresidential Building Operators 72 Personal Services 7215 Coin-operated Laundries and Cleaning 76 Miscellaneous Repair Services 7699 Repair Services, Nee 80 Health Services 8060 Hospitals 8070 Medical and Dental Laboratories 3 5 1 1 3 11 SUMMPCB.XLS 5 of6 09/11/94 Virtual Ulimiiialion Pilot Project I'CIl Sources unit Rcguhithms Appendix III: Summary of PCB Reporting Data SIC ategory 87 SIC Code : 8091 Health and Allied Service, NEC Engineering and Management Services 8730 Research and Testing Services 8731 Commercial Physical Research 8734 Testing Laboratories Grand Total Total IL 1N MI MN N Y OH PA WI m PCS m PCS TRI PCS TRI PCS M TRI PCS TRI PCS TRI PCS TRI PCS TRI PCS K 9 37 11 10 1 3 5 18 360 2 1 1 7 2 10 SUMMPCB.XLS 6 of6 0 1WI /W Appendix: II2a TRI PCB DATA, THE EIGHT GREAT LAKES STATES Tkg/yr) :TIHG YEAR: 1992 EAT LAKES iSIN STATE N MN N MN r Ml N PA Y NY Y MI Y MI N MI Y IN SICCODE 2819 2911 3241 3274 3313 3321 3321 3612 3621 FACILITY NAME KOCH REFINING CO. ; KOCH REFINING CO. LAFARGE CORP. MILLARD LIME A STONE CO. SPECIAL METALS CORP. TEXTRON INC. MARTIN FOUNDRIES CO. DYNEX ENVIRONMENTAL INC. GE CO. ROLE OF PCB 3C 3C 3C 3C 3C 3C 3B 3C 3C SOURCE REDUCTION ACTIVITIES A ID METHODS NA NA NA NA U52T01T04T10NA NONPT AIR 0 0 0 0 0 0 0 0 0 POINT AIR 0 0 0 0 0 0 0 0 0 WATER 0 0 0 0 0 0 0 0 0 UNDRGRND 0 0 0 0 0 0 0 0 0 LAND 1 0 0 0 0 0 0 0 0 POTW 0 0 0 0 0 0 0 0 0 OFFSITE 1 0 214469 0 26400 12268 0 896647 41308 TOTAL RELEASES 2 0 214469 0 26400 12268 0 896647 41308 OF PCB AND ITS USES AT THE FACILITY SOURCE REDUCTION ACTIVITIES Otherwise use the toxic Chemical A * As a chemical processing aid B = As a manufacturing afd C * Ancillary or other use U52 * Modified equipment, layout or piping ee Toxic Chemical Release Inventory, data downloaded June 21, 1994 METHOOS USED TO 10 SOURCE REDUCTION ACTIVITIES T01 Internal Pollution Prev. Opportunity Audtt(s) T04 Participative Team Management T10 * Vendor Assistance Appendix H2b TRI PCB DATA, THE EIGHT GREAT LAKES STATES <kg/yr) TING TEAR: 1991 EAT LAKES 5IN STATE Nm N PA N PA N NY T MI N IL N OH M IL N PA N Mi N MI SICCODE 2911 3241 3274 3313 3321 3333 3443 3462 3585 3612 3714 i FACILITY NAME KOCH REFINING CO. i ESSROC MATERIALS INC. MILLARD LIME ft STONE CO. SPECIAL METALS CORP. MARTIN FOUNDRIES CO. BIG RIVER ZINC CORP. BABCOCK fc WILCOX CO. KRUPP GERLACH CRANKSHAFT CO. FRICK CO. DYNEX ENVIRONMENTAL INC. CMC ROLE OF PCB 3C 3C 3C 3C 30 3C 3C 3B 3C 3C 3C SOURCE REDUCTION ACTIVITIES ft ID METHODS NA HA NA NA NA NA NA NANA NA NONPT AIR 0 0 0 0 0 0 0 0 0 0 0 POINT AIR 0 0 0 0 0 0 0 0 0 0 0 WATER UNDRGRND 00 00 00 00 00 00 00 00 00 00 00 LAND 0 0 0 0 0 0 0 0 0 0 0 POTW 0 0 0 0 0 0 0 0 0 0 0 TOTAL OFFSITE RELEASE! 490 490 40417 40417 00 27190 27190 00 00 2000 2000 1890 1890 75000 75000 435801 435801 750 750 OF PCB AND ITS USES AT THE FACILITY SOURCE REDUCTION ACTIVITIES itherwise use the toxic chemical i As a chenieal processing eld As a manufacturing aid : * Ancillary or other use U52 * Modified equipment, layout or piping :e: Toxic Chemical Release Inventory, data downloaded June 21, 1994 METHODS USED TO ID SOURCE REDUCTION ACTIVITIES T01 Internal Pollution Prev. Opportunity Audit<s> T04 * Participative Team Management T10 * Vendor Assistance APPENDIX H3a: PCB DISCHARGES IN THE GREAT LAKES BASIN JULY 1992 - JUNE 1993 (PCS DATA) SIC CODE/SIC NAME ___________________________________ 26 Paper & Allied Products 2611 Pulp mills 2621 Paper mills, except building paper 28 Chemicals and Allied Products 2899 Chemical preparations, not elsewhere classified 33 Primary Metal Industries 3334 Primary aluminum 3341 Secondary nonferrous metals 35 Machinery, Except Electrical 3519 Internal combustion engines, not elsewhere classified 37 Transportation Equipment 3714 Motor vehicle parts and accessories 49 Electric, Gas and Sanitary Services 4952 Sewerage systems 4953 Refuse systems TOTALS: NUMBER of FACILITIES 4 1 1 2 1 1 2 24 1 37 TOTAL PCB DISCHARGES (kg/yr) ' 0.16 0 0 0.02 1.25 1.08 2.52 11.01 0 16.04 RANGE of RELEASES (kg/yr) 0-0.16 0 0 0 - 0.02 1.25 1.08 0.01 -2.51 0 - 4.96 0 0 - 4.96 Note: This table shows the number of facilities in the Great Lakes basin, by SIC code, that reported PCB discharges under the Permit Compliance System (PCS). PCS data approximates point source loads from municipal and industrial discharges. Information is based on monitoring data supplied by regulated facilities. Key: Number of Facilities .*= it of facilities reporting Total PCB Discharges = total PCB discharges from all facilities reporting in each SIC code. Range =* range of reported releases from all sources reporting in each SIC code. Source: Permit Compliance System APPENDIX H3b: PCB DISCHARGES IN THE GREAT LAKES BASIN JUNE 1991 - JULY 1992 (PCS DATA) SIC CODE/SIC NAMEFACILITIES (kg/yr) 26 Paper & Allied Products 2611 Pulp mills 2621 Papet mills, except building paper 28 Chemicals and Allied Products 2899 Chemical preparations, not elsewhere classified 33 Primary Metal Industries 3334 primary aluminum 3341 Secondary nonferrous metals , 35 Machinery, Except Electrical 3519^Internal combustion engines, not elsewhere classified 37 Transportation Equipment 3714; Motor vehicle parts and accessories 49 Electric, Gas and Sanitary Services 4952 Sewerage systems 4953 Refuse systems NUMBER of TOTAL PCB DISCHARGES RANGE of RELEASES (kg/yr) 3 0.08 0 - 0.08 2 00 1 0.01 0.01 2 0.03 0 - 0.03 1 0.06 0.06 1 1.07 1.07 3 8.78 0 - 6.47 TOTALS: 24 1 38 51.77 1.20 63.0 0-31.94 1.20 0 - 31.94 Note: This table shows the number of facilities in the Great Lakes basin, by SIC code, that reported PCB discharges under the Permit Compliance System (PCS). PCS data approximates point source loads from municipal and industrial discharges. Information is based on monitoring data supplied by regulated facilities. Key: iiiiiiliisliiiliiiiiliiiiiii1 Number ofFacilities ~ # of facilities reporting ; Total Mercury:Discharges^-- total PCB discharges from all facilities reporting in each SIC code. Range = range of reported releases from all sources reporting in each SIC code. Source: Permit Compliance System Vicinal Klimmalion Pilot Projecl PCIt Sources nml Regulations Appendix H4: Wisconsin PCB Emissions (Air point sources, 1992 Data) SIC Codc/SIC Name___________________________ 26 Paper and Allied Products 2631 Paperboard Milts 2679 Converted Paper Products, NEC 82 Health Services 8091 Health and Allied Services, NEC Total HG Number of Emissions Facilities_____ (pountls/yr) 1 0.396 1 1.188 TOTALS: 1 3 0.5 2.084 Range of Releases (pounds/yr) 0.396 1.188 0.5 .396 -1.188 NOTE: This table shows die facilities (by SIC code) that reported mercury emissions under Wisconsin's Clean Air Act Title V Operating Permits Program. Under the Title V Program, state may impose fees up to $25/ton of emissions of all eligible substances. In Wisconsin, facilities report emissions that exceed 1 pound. In some cases, mercury emissions may be linked to processes such as fuel combusion that are independent of SIC codes. :' : . . KEY: Number of Facilities = # of facilities reporting emissions, equal or greater than 1 lb. Total Emissions3 total Hg emissions from all sources reporting in each SIC Code. Range ** range of reported releases from all sources reporting in each SIC Code. Ross& Associates Environmental Consulting. Ltd. Appendix H5: Michigan Critical Materials Wastewater Report - 1991 data (PCBs) SIC SIC Code Name Number of Facilities 10 Metal Mining 1011 1021 1081 Iron Ores Copper Ores Metal Mining Services 1 1 1 14 Nonmetallic Minerals 1422 1440 Crushed And Broken Limestone Sand and Gravel 4 2 20 Food and Kindred Products 2050 2063 2087 Bakery Products Beet Sugar Flavoring Extracts And Syrups, Nec 1 3 1 24 Lumber and Wood Products 2493 Reconstituted Wood Products 2 25 Furniture and Fixtures 2500 2522 2591 Furniture and Fixtures Office Furniture, Except Wood Drapery Hardware And Blinds And Shades 7 3 1 26 Paper and Allied Products 2600 2621 2631 2640 2650 2651 2670 Paper and Allied Products Paper Mills Paperboard Mills Paperboard Containers and Boxes Misc. Converted Paper Products 2 13 6 1 1 1 1 27 Printing and Publishing 2700 2710 2750 2782 2790 Printing and Publishing Newspapers Commercial Printing Blankbooks And Looseleaf Binders Printing Trade Services 1 3 2 1 1 28 Chemicals and Allied Products 2800 2810 2813 2820 2830 2840 2850 2851 2860 Chemicals and Allied Products Industrial Organic Chemicals Industrial Gases Plastic Materials and Synthetics Drugs Soap, Cleaners, and Toilet Goods Paints and Allied Products Paints And Allied Products Industrial Organic Chemicals 2 2 1 2 4 I 2 2 4 NOTE This table shows the facilities (by SIC code) that repotted PCBs under Michigan's Critical Materials and Wastewater Data System; In this program, Michigan collects information about use and release of chemicals included on its "Critical Materials Registry." KEY: Facilities " number of facilities reporting PCBs > 1 lb. in each sic code. Ross & Associates Environmental Consulting, Ltd PC8I.XLS 09/11/94 Appendix H5: Michigan Critical Materials Wastewater Report - 1991 data (PCBs) SIC SIC Code Name 28 Chemicals and AUk-. Products (continued) 2865 2870 2890 2891 2899 Cyclic Cnicies And Intermediates Agricultural Chemicals Misc. Chemical Products Adhesives And Sealants Chemical Preparations, Nec 29 Petroleum and Coal Products 2900 2911 Petroleum and Coal Products Petroleum Refining 30 Rubber and Misc. Plastics 3053 3069 3079 3080 3220 3221 3241 3273 3274 3290 3295 3297 Gaskets, Packing And Sealing Devices Fabricated Rubber Products, Nec Miscellaneous Plastics Products, NEC Glass and Glassware, Pressed or Blown Glass Containers Cement, Hydraulic Ready-Mixed Concrete Lime Misc. Nonmetallic Mineral Products Minerals, Ground or Treated Nonclay Refractories 33 Primary Metal Industries 3312 3313 3316 3317 3320 3321 3322 3339 3340 3341 3354 3360 3365 3366 3369 3398 Blast Furnaces And Steel Mills Electrometallurgical Products Cold Finishing Of Steel Shapes Steel Pipe And Tubes Iron and Steel Foundries Gray And Ductile Iron Foundries Malleable Iron Foundries Primary Nonferrous Metals, Nec Secondary Nonferrous Metals Secondary Nonferrous Metals Aluminum Extruded Products Nonferrous Foundries (Castings) Aluminum Foundries Copper Foundries Nonferrous Foundries, Nec ' Metal Heat Treating 34 Fabricated Metal Products 3400 Fabricated Metal Products 3442 Metal Doors, Sash, And Trim 3449 Miscellaneous Metal Work 3460 Metal Forgings and Stampings 3462 Iron And Steel Forgings 3465 Automotive Stampings 3471 Plating And Polishing 3479 Metal Coating And Allied Services 3490 Misc. Fabricated Metal Products 3499 Fabricated Metal Products, Nec tciales Environmental Consulting. Ltd. Number of Facilities 2 1 2 2 3 1 2 1 3 4 11 3 1 5 1 1 1 5 2 6 1 5 1 1 10 2 1 4 1 1 1 1 2 1 6 5 1 1 1 6 13 4 1 9 1 PCB1.XLS 09/11/W Appendix H5: Michigan Critical Materials Wastewater Report - 1991 data (PCBs) SIC SIC Code Name Number of Facilities 35 Industrial Machinery and Equipment 3510 3530 3540 3544 3545 3550 3566 3570 3580 ______ 3590 Engines and Turbines 5 Construction and Related Machinery 2 Metalworking Machinery 1 Special Dies, Tools, Jigs, And Fixture 1 Machine Tool Accessories 1 Special Industry Machinery 3 Speed Changers, Drives, and Gears 1 Computer and Office Equipment 1 Refrigeration and Service Machinery 1 Industrial Machinery, NEC______________________________________ 1 36 Electronic & Other Electric Equipment 3620 3621 3630 ______ 3651 Electrical Industrial Apparatus Motors and Generators Household Appliances Household Audio And Video Equipment 1 1 1 I 37 Transportation Equipment 3710 3711 3714 ______ 3790 Vehicles and Equipment Motor Vehicles And Car Bodies Motor Vehicle Parts And Accessories Miscellaneous Transportation Equipment____________________ 3 15 46 1 38 Instruments and Related Products 3812 3840 3843 Search and navigation equipment Medical Instruments and Supplies Dental Equipment And Supplies 1 1 1____ 39 Miscellaneous Manufacturing Industries 3940 3970 3990 Toys and Sporting Goods Miscellaneous Manufactures1 1 1 42 Trucking and Warehousing 4230 Trucking Terminal Facilities 1____ 47 Transportation Services 4785 Inspection And Fixed Facilities 1 49 Electric, Gas, and Sanitary Services _____ 4911 Electric Services 21 50 Wholesale Trade Durable Goods 5013 Motor Vehicle Supplies And New Paris-Wholesale Trade3 65 Real Estate 6512 Nonresidential Building Operators 5 72 Personal Services 7215 Coin-operated Laundries and Cleaning1 76 Miscellaneous Repair Services _____ 7699 Repair Services, Nec___________________________________________ 1 80 Health Services 8060 8070 Hospitals Medical and Dental Laboratories 3 1 Ross < Associates Environmental Consulting, Ltd PCWB1l.lX/9LS4 Appendix H5: Michigan Critical Materials Wastewater Report - 1991 data (PCBs) SIC SIC Code Name 87 Engineering & Management Services 8730 8731 8734 Research and Testing Services Commercial Physical Research Testing Laboratories Total: Number of Facilities 10 1 3 360 Ross <fc Associates Environmental Consulting, Ltd. K81JU 09/11/M KILOGRAMS 34118K Appendix H6 1,000.000, 000 1990/1991/1992 NATIONAL SUMMARY FROM PCB ANNUAL REPORT (IN KILOGRAMS x 1000 (K DISPOSED DURING YEAR 100,000,000 .10 000^000 1.000,000 100,000 10,000 1,000 Capacitors Artiela Containers Transformers 1990 1991 M 1992 Bulk PCB Containers Please note scale values UNITS 4,819,796 Appendix H6 ,10 000,000 1990/1991/1992 NATIONAL SUMMARY FROM FOB ANNUAL REPORT |W UMTS) DISPOSED DURING YEAR 1,000,000 100.0Q0 10,000 1,000 100 10 Capacitors Article Containers Transformers 1990 1991 M 1992 PCB Containers Please note scale values