Document 5LGKO4MExxB577r9ZjNpX0X75
ABDOO136642
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month of: February Date of Report: April 3, 1984
1. ROUTINE CHEMICAL DOSIMETRY
All Sample Results:
Chemical
< PEL No. %
> PEL (OVEREXPOSURE) No. %
VCM Lead Total Particulates
2.5 96.2 32 97.0 12 100.0
1 1 0
3.8 3.0 0.0
Overexposures
Job Class
Exposure
Source
Line Compounder
61.1* Micrograms Lead/m^
Employee overexposed while charging Line III blenders No specific cause has been identified.
Chief Operator
29.1* ppm, VCM
Employee overexposed while helping change VCM filter pack filters.
NOISE CONTROL
Resin deboxing area noise was reduced during February by insulating the cone at the bottom of the Sweco screener feed hopper. Noise level measurements taken before and after the insulation, using a General Radio Model 1565-B sound level meter, were :
Location
Noise Level, dBA
Before Insulation
After Insulation
1. 2 ft. from cone, on mezzanine
110
98-103
2. 16 ft. from cone, at ground level
95
92
3. Main traffic isle, at south door*
93
89
*84 dBA with hopper vibrator "off".
Industrial Hygiene Report Page 2
ABDOO136643
3. GMD SYSTEMS, INC. PASSIVE MONITOR
The lab-based familiarization study of the passive, VCM monitor marketed by GMD Systems, Inc. was completed. The second phase of the evaluation, involving reproducibility studies, was begun.
cc: JF, CRM,
WFH, CRS, RAF, RAM, AHS
Tom Grumbles - Houston
J. R. Drumwright, M.D. Ponca City