Document 5L8vewMwoGLZQpG83MNMK1bYz

f=>occ "Sg O^ce. "2 ill O Lo<U >- o ZowQqO: QSujZ' OcjD 5I oo OooKSq;| QO=^o< s.i CL. 4-*; 4 GO ft, ^ v n* V < ' |b n 'i o:Z 0><0-: <*9 UJ Ll_ c h- o < > o 262 MOTOR CONTROL FOR SPECIFIC APPLICATIONS A-c 3 Phase Full Voltage Pumping Plant Control WHEN ORDERING SPECIFY Catalog number Heater coil catalog number, see page 282. WITH "START, STOP-RESET" BUTTONS 0 Maximum Horsepower 60 Cycles 220 V. 440 V. NEMA Size Fusible Motor Circuit Switch Type Fuse Clip Rating Weatherproof NEMA 3 0 Enclosure Amps. Volts Cat. No. Price Circuit Breaker Type Type of Breaker Frame Weatherproof NEMA 3 0 Enclosure Cat. No. Price 2 COIL OVERLOAD RELAY 3(7H) 5 7% 714(10) 10 1 9589- 9591- 30 250 P121-. $104. E-20A P1212 $108. 60 250 . P122 106. E-40A P1214 108. 60 250 P122 106. E-50A P1215 108. 30 600 P141 . 106. EH-30A P1423 135. 60 600 P142 108. EH-40A P1424 . 135. 7V4(15) 15 15(25) 25 30 ... ... 30(50) ... 50 40 ... 50 ... ... 75(100) ... 100 75 100 ... ... 150(200) ... 200 2 3 4 5 60 250 P222 100 250 P223 60 600 P242 , 100 600 P243 172. E-50A 172. E-90A 164. EH-50A 173. EH-70A P2215 P2217 P2425 P2426 163. 163. 190. 190. 200 250 P324 284. E-100A P3218 0273. 100 600 P343 . 268. EH-100A P3428 273. 200 600 P344 287. EH-100A P3428 . . 0273. 200 250 P424 ; 400 250 P425 200 600 P444 400 600 P445 485. JA-150A P4232 530. JA-200A P4234 488. JA-175A P4433 535. JA-200A P4434 570. 570. 570. 570. 400 250 P525 600 250 P526 400 600 P545 600 600 P546 1105. LA-300A P5242 1129. LA-400A P5243 1035. LA-300A P5442 1170. LA-400A P5443 1215. 1215. 1270. 1270. 3 COIL OVERLOAD RELAY Factory Assembled 3 coil starters, add suffix "T" to catalog number and through size 4, add $4., for size 5 add $40. Field conversion from 2 coil to 3 coil through size 4, use spindle kit 10176H150--$2.50 and heater coil--$1.50. O For normal starting duty only. For long timo acceleration, JA frame breakers are provided at $105. extra. 0 Cat. No. 9SS9 dual element fuse ratings shown in parentheses. 0 Standard enclosure is aluminum finished, ventilated, ond without door gasket. For gray finish, non-ventilated or gasketed enclosure, see optional features or specify desired enclosure features on order. APPROXIMATE DIMENSIONS AND SHIPPING WEIGHTS P61 panel installed. NEMA Size 1 2 3 4 5 Wide A 19 19 21 2414 2616 Dimensions in Inches High Deep BC 31Vi 914 3114 914 4114 1054 48 12 60 12 Mounting DE 10 3014 10 3014 10 4014 32 42 32 56 Ship. Wt. Lbs. 70 80 125 185 280 OPTIONAL FEATURES --Add dash(--) to above Cat. Nos. and follow with code number of features selected. Code No. Description 1 Substitute "Run-Off-Auto" selector switch for "Start-Stop" ...................................................................................................... 2 Add phase reversal relay....... ....................................................................................................................................... 3 Add time delay relay timed after Stop--3 min. max....................................... ...................................................................... 4 Add time delay relay timed before Start--3 min. max.............................................................................................................. 6 Substitute gray finished, non-ventilated, gasketed enclosure for standard enclosure ...................................................................... 7 Add single cycle lockout relay for inherent protected motors................................................................................................... 8 Add "Run-Off-Auto" Switch--Start button to operate in "Run" position........................................................................................ 9 Add 3 single phase lightning arrestors................................................................................................................................ ... Open type Water Flood Panel with programming timer, 3 single phase lightning arrestors and terminal board--Catalog Number 9589P60 Above Water Flood Panel with time delay under voltage release--Catalog Number 9589P61 ..... ................................................... SELECTOR SWITCH CONVERSION KIT Size Cat. No. Description 1 P1001-S Kit for field conversion--"Start-Stop" to "Run-Off-Auto"............................................................................ 2 P2001-S r 3 . P3001-S Price Addition No Charge $118 84. 84. No Charge 30. No Charge 40. 90. 110. Price $11.40 11.40 11.40 I CUTLER-HAMMER 262 DISCOUNT SCHEDULE 1 CD