Document 5L8vewMwoGLZQpG83MNMK1bYz
f=>occ "Sg O^ce. "2
ill
O Lo<U
>- o
ZowQqO:
QSujZ' OcjD
5I
oo
OooKSq;| QO=^o<
s.i CL. 4-*; 4 GO ft, ^ v
n* V < '
|b n 'i
o:Z
0><0-:
<*9
UJ Ll_ c
h- o <
> o
262
MOTOR CONTROL FOR SPECIFIC APPLICATIONS
A-c 3 Phase Full Voltage Pumping Plant Control
WHEN ORDERING SPECIFY Catalog number
Heater coil catalog number, see page 282.
WITH "START, STOP-RESET" BUTTONS
0 Maximum Horsepower 60 Cycles
220 V. 440 V.
NEMA Size
Fusible Motor Circuit Switch Type
Fuse Clip Rating
Weatherproof NEMA 3 0 Enclosure
Amps. Volts Cat. No. Price
Circuit Breaker Type
Type of
Breaker Frame
Weatherproof NEMA 3 0 Enclosure
Cat. No. Price
2 COIL OVERLOAD RELAY
3(7H) 5 7%
714(10) 10
1
9589-
9591-
30
250
P121-.
$104. E-20A
P1212 $108.
60 250 . P122
106. E-40A
P1214
108.
60 250 P122
106. E-50A
P1215
108.
30 600 P141 .
106. EH-30A P1423
135.
60 600 P142
108. EH-40A P1424 . 135.
7V4(15) 15
15(25) 25 30 ... ... 30(50) ... 50 40 ... 50 ... ... 75(100) ... 100
75 100 ...
... 150(200) ... 200
2 3 4 5
60 250 P222 100 250 P223 60 600 P242 , 100 600 P243
172. E-50A 172. E-90A 164. EH-50A 173. EH-70A
P2215 P2217 P2425 P2426
163.
163. 190. 190.
200 250 P324
284. E-100A
P3218 0273.
100 600 P343 . 268. EH-100A P3428
273.
200 600 P344
287. EH-100A P3428 . . 0273.
200 250 P424 ; 400 250 P425 200 600 P444 400 600 P445
485. JA-150A P4232 530. JA-200A P4234
488. JA-175A P4433 535. JA-200A P4434
570.
570.
570. 570.
400 250 P525 600 250 P526 400 600 P545 600 600 P546
1105. LA-300A P5242 1129. LA-400A P5243 1035. LA-300A P5442
1170. LA-400A P5443
1215. 1215. 1270.
1270.
3 COIL OVERLOAD RELAY
Factory Assembled 3 coil starters, add suffix "T" to catalog number and through size 4, add $4., for size 5 add $40.
Field conversion from 2 coil to 3 coil through size 4, use spindle kit 10176H150--$2.50 and heater coil--$1.50.
O For normal starting duty only. For long timo acceleration, JA frame breakers are provided at $105. extra. 0 Cat. No. 9SS9 dual element fuse ratings shown in parentheses.
0 Standard enclosure is aluminum finished, ventilated, ond without door gasket. For gray finish, non-ventilated or gasketed enclosure, see
optional features or specify desired enclosure features on order.
APPROXIMATE DIMENSIONS AND SHIPPING WEIGHTS
P61 panel installed.
NEMA Size
1 2 3 4 5
Wide A
19 19 21 2414 2616
Dimensions in Inches
High Deep BC
31Vi 914 3114 914 4114 1054 48 12 60 12
Mounting
DE 10 3014 10 3014 10 4014 32 42 32 56
Ship. Wt. Lbs.
70 80 125 185 280
OPTIONAL FEATURES --Add dash(--) to above Cat. Nos. and follow with code number of features selected.
Code No. Description
1 Substitute "Run-Off-Auto" selector switch for "Start-Stop" ...................................................................................................... 2 Add phase reversal relay....... ....................................................................................................................................... 3 Add time delay relay timed after Stop--3 min. max....................................... ...................................................................... 4 Add time delay relay timed before Start--3 min. max.............................................................................................................. 6 Substitute gray finished, non-ventilated, gasketed enclosure for standard enclosure ...................................................................... 7 Add single cycle lockout relay for inherent protected motors................................................................................................... 8 Add "Run-Off-Auto" Switch--Start button to operate in "Run" position........................................................................................ 9 Add 3 single phase lightning arrestors................................................................................................................................ ... Open type Water Flood Panel with programming timer, 3 single phase lightning arrestors and terminal board--Catalog Number 9589P60
Above Water Flood Panel with time delay under voltage release--Catalog Number 9589P61 ..... ...................................................
SELECTOR SWITCH CONVERSION KIT
Size Cat. No.
Description
1
P1001-S
Kit for field conversion--"Start-Stop" to "Run-Off-Auto"............................................................................
2 P2001-S r
3 . P3001-S
Price Addition
No Charge $118
84. 84. No Charge 30. No Charge 40. 90. 110.
Price
$11.40 11.40 11.40
I
CUTLER-HAMMER
262
DISCOUNT SCHEDULE 1 CD