Document 5L4B6MpBDXRLrxmRam0B9pVZD

300 CHAPTER 21 1959 Guide Table 13 .... Weights and Thicknesses of ct,,.j..j rKn.r.ci...M ItaM to Wtiglif Waighl per Sq H IMdmit, Indm Neared Gage No. Oz Lb Decimal Nearest EqoWalcnt Fraction B.&S. Stubs U. S. Std. 10 0.625 0.0135 He 27 12 0.750 0.0162 Ms ' 26 14 0.875 0.0189 X. 25 16 1.000 0.0216 Xi 23 IS 1.125 0.0243 Xl 22 29 27 26 24 23 20 1.250 0.0270 Hi 21 22 24 1.500 0.0324 Hi 20 21 . 28 1.750 0.0378 Hi 19 20 32 2.000 0.0432 X. 17. 19 36 2.250 0.04S6 X. 16 18 40 2.500 0.0540 He 44 2.750 0.0594 Ms 48 3.000 0.0648 X. 56 3.500 0.0756 H* 64 4.000 0.0864 X. 15 17 15 17 14' 16 13 15 11 14 * Variations from tbeee weights most be expected in practice. JL 29 28 28 25 24 23 22 20 19 18 17 17 16 14 13 SUP CLP r p ^ " 6L S_ _J_ countered in the field, but in general, long-radius elbows and accompanied by decreased turbulence, lower resistance, and a minimum of noise. Heavy canvas connections are recommended on both the inlet and outlet to all fans. Self-vulcanizing adhesive tapes are available for this purpose and for sealing joints in duct work. Where a fire hazard exists, the material used must satisfy the requirements of any codes or authorities having jurisdiction. The fan discharge connections shown in fig. 16 are marked good, fair, and poor in the order of the amount of turbulence produced. An inspection of the heater connec tions shown in Fig. 16 will readily show that uniform velocity through the heater cannot be expected in the diagram noted poor. When obstructions cannot be avoided, the duct area should never be decreased more than 10 percent, and then a streamlined collar should be used. Larger obstructions re quire an increase in the duct size in order to maintain as nearly uniform velocity as possible. Branch take-offs should always be arranged to cut or dice into the air stream in order to reduce as far as possible the losses in velocity head. Wherever ducts pass through fire walls or connect two fire areas of a building, automatic fire dampers should be pro vided. For design of such dampers and other fire-protective details, see Pamphlet No. 90A of the National Board of Fire Underwriters " HEAT LOSSES FROM DUCTS In designing duct systems, the heat gains or losses of the ducts can be quite considerable, not only if the duct pagans through unconditioned .space, but also on .long duct-runs within conditioned space. Proper insulation will remedy this situation considerably, but sometimes a redistribution of the supply air is necessary in order to compensate for the heat exchanges that occur. . The heat loss from a given length of duct can be expressed by: Q. - UPl K^H (14) where T y-f <* tCATCR, ftTER, AMD WkSHCft COMCCTONS CASXCMT MXK) On'Qrrot type clmch collar (WUINUII TYPC BRANCH TAKCOm Rg. 16.... Sheet-Metal Duct and Arrangement Details Q = heat loss through duct walls, Btu per hour. U -- overall coefficient of beat transfer for the duct wall, Btu per (hour) (square foot) (Fahrenheit degree). P = perimeter of-duct, feet. . 1 = length of duct, feet. h " temperature of air entering duct, Fahrenheit. It " temperature of air leaving duct, Fahrenheit. U " temperature of air surrounding duct, Fahrenheit. To obtain' the temperature drop in warm air for a given distance of transmission, or the temperature rise if the duct carries air cooler than the room, through which it paaspa, the following formulas can be used: kiy + 1) - 21| (y - 1) , <>(y ~ 1) + (y + 1) (15) (16) 28AVp , y - -rfor rectangular ducts or. Air Duct Design 301 sulated with V4-ia. of a material having a conductivity of 035 Btu at 86 F mean temperature, carrying air at a velocity of 1200 fpui, measured at 70 F, to deliver air at 120 F with air surround ing the duct at 40 F. Solution: Referring to Fig. 17, the overall beat transmission coefficient is found to be 0.49 Btu. From Table 2, Chapter 3,.the density of air at 70 F and 29.921 in. Hg is found to be 1/13348 -- 09749 lb per cu ft. Substituting these and the other given values in Equation 16, y and h will be as follows: 28.8 X 6 X 1200 X 0-0749 45.3 0.49 X 10 X 70 120(453 + 1) - 80 1<M, ' ' 453 -1 KSubstituting in Equation 14: - 0.49 X 10 --123.7 +--120)\ -401J Thkkmts of (mutation (fadiei) H 1 1.H .2 12- to 21-in. Duct Diameter................... 3% 5% 7% 9% 21- to 30-in. Duct Diameter................... 1% 2% 3% 4% Rg. 17____Heat Loss Coefficients for Insulated Ducts* 13S>Vp - for round ducts, Ul A = cross-sectional area of duct, square feet. p " density of air, pounds per cubic foot. V -- mean velocity of fluid, feet per minute. D =* diameter of round duct, feet. In using Equations 15 and 16, one of the duct air tempera tures will be unknown and will be obtained by substitution of the other known or assumed values. Heat loss coefficients for insulated ducts- with various con ductivities are given in Fig. 17. The conductivities of various materials, which are based on mean temperatures, about 70 F,-wUl be found in Table 4 of Chapter 9. For cases where the mean temperature is other than that at which the test was conducted, a correction should be made. However, in most cases the effect of this'factor will be small and may be ne glected.* . Example 8: Determine the entering air temperature and heat loss for a duct 24 x 36 in. crosa^ection and 70 ft in length, in- = 28400 Btu per hr. For special considerations which apply to insulation of . ducts in marine installations see Chapter 48. REFERENCES *D. K. Wright, Jr.: ASHVE Reseabch Report No. 1280--A new friction chart for round ducts (ASHVE Transactions, Vol. 51,1945, p.303). *L. F. Moody: Friction factors for pipe flow (ASMS Trans actions, Vol. 66, 1944, p. 671). * R. D. Madison and W. R. Elliot: Friction charts for gases including correction for temperature, viscosity and pipe rough ness (ASHVE Journal Section, Heating, Piping and Air Con ditioning, October 1946, p. 107). *F. W. Hutchinson: ASHVE Research Report No. 1469-- Friction losses in round aluminum ducts (ASHVE Trans actions, Vol. 59, 1953, p. 127). * R. G. Huebscher: Friction equivalents for round, square and rectangular ducts (ASHVE Transactions, Vol. 54, 1948, p. 101).. D. W. Locklin: ASHVE Research Report -No. 1405-^Energy losses in 90-degree duct elbows: A survey and analysis of available information (ASHVE Transactions, Vol. 56, 1950, p. 479). * J. R. Weske: Pressure Loss in Ducts with Compound Elbows (National Advisory Committee for Aeronautics, Advance Re stricted Report W-39, February 1943). 'R. D. Madison and J. R. Parker: Pressure losses in rec tangular elbows (Heating, Piping and Air Conditioning, July, p. 365; August, p. 427; September, p. 483; 1936). . *W. H. Carrier, R. E. Cherne, and W. A. Grant: Modem Air Conditioning, Heating and Ventilating-(Pitman Publishing Corp,, New York, 1950, 2nd ed., p. 248). "Ml C. Stuart, C. F. Warner, and W. C. Roberts: ASHVE Research Report No. 1216--Effect of vanes in reducing loss in elbows in seven-inch square ventilating duct (ASHVE Trans actions, Vol. 48, 1942, p. 409). "8. F. Gilman: .Pressure losses of divided-flow fittings (ASHAE Transactions, Vol. 61, 1955, p. 281). "G. E. McElroy: Pressure Losses Due to Bends and Area y' Changes m Mine Airways (U. S. Bureau of Mines Information Circular l.C. 6663, p. 4). "A. P. Knits and J. R. Fellows: Pressure Losses Resulting from Changes in Cross-Sectional Area in Air Ducts (University of Illinois, Engineering Experiment Station Bulletin No. 300). MR. D. Madison (ed.): Pan Engineering (Buffalo Forge Company, Buffalo, New York, 1948, 5th ed-, p. 124). u J. R. Henry: Design of Power-Plant Installations: PressureLoss Characteristics of Duct Components (National Advisory Committee for Aeronautics, Advance Restricted Report L4F26, June 1944, L-20S). " L. O. Paul: installing ducts for higher pressures, and Why higher duct velocities? (Heating, Piping and Air Conditioning, April 1953, p. 98 and February 1954, p. 109).