Document 5L1zn03JEmxEvRggE3LEkMXpz

John A. Jurgiel & Associates, Inc. Occupational >lKeallh and ^Safely Consultant* December 30, 1985 2C32 CONCOURSE OrtIVE SY. LOUIS. MISSOURI *3146 13 I 4| 5 67-7 486 Mr. Jim Grizzle Safety Supervisor Shell Oil Company Post Office Box 262 Wood River, Illinois 62095 Dear Jim: Bill Cunningham has pointed out a calculation error in my December 17, 1985, summary of the CCU-2 shutdown. The error was in the- calculation of the TLV for .Quartz (silica) during sandblasting operations in the regenerator. Enclosed is my corrected report reflecting table and narrative changes. I am sorry for any inconvenience the December 17 report may have caused. cc: Bill Cunningham [Shell Oil] Enclosure DNN/kn LAM 023922 ABS-007104 CCU-2 INDUSTRIAL HYGIENE PROJECT SUMMARY \ December 30, 1985 By John A. Jurgiel & Associates 2092 Concourse Drive St. Louis, Missouri 63146 LAM 023923 ABS-007105 RESULTS OF AIR MONITORING DURING CCU-2 TURNAROUND SAMPLE NO. - TIME ON - OFF LOCATION CONTAMINANT/UNITS \ Removal of refractory from Regenerator, September 29, RESULTS 1985. CCU2-1 0820-1354 Downwind of 'Super Sucker' Asbestos f/cc N.D. CCU2-2 0825-1354 Next to conex box Asbestos f/cc 0.013 CCU2-3 0831-1350 Outside of 60" manway Asbestos f/cc 0.0092 CCU2-4 0834-1349 Inside 'Regen' under ladder at 60" manway Asbestos f/cc 0.782 CCU2-5 1157-1349 Inside 1 Regen' on work platform Asbestos f/cc 1.77 Removal of refractory from Regenerator, October 1, 1985 CCU2-6 0941-13.58 Downwind from super sucker. . Asbestos f/cc N.D, CCU2-7 0943-1357 Next to conex box Asbestos f/cc 0.015 CCU2-8 0946-1354 Outside 60" manway Asbestos f/cc 0.006 CCU2-9 0949-1347 Inside 'regen' under ladder at 60" manway Asbestos f/cc 2.99 CCU2-10 0949-1347 Inside 'regen' on operator platform Asbestos f/cc 3.05 Manual removal of refractory from Regenerator with air movers on, October 10, 1985. CCU2-11 Outside area sample Asbestos f/cc at outlet to air mover on level 13 0.118 TL' 2.0 f M 11 It .2.0 II 11 M It 11 LAM 023924 ABS-007106 4 / RESULTS OF AIR MONITORING DURING CCU-2 TURNAROUND continued SAMPLE NO. TIME ON - OFF CCU2-12 LOCATION CONTAMINANT/UNITS \ Outside area sample downwind of air mover on level 13 Asbestos f/cc RESULTS 0.031 CCU2-13 1414-1543 Personal sample on Louis Finley Asbestos f/cc 1.28 CCU2-14 1418-1543 Area sample in bottom of 'regen1 Asbestos f/cc 1.05 Manual removal of refractory from Regenerator with air movers on, October 11, 1985 . CCU2-15 1947-2150 Personal sample on Don Chappel1 Asbestos f/cc .2.12 CCU2-16 1949-2150 Area sample in bottom of 'regen' Asbestos f/cc 3.23 Sandblasting in Regenerator with air movers on, October 14, 1985. TLV II 2.0 tl If It CCU2-18 1356-1545 Outside 60" manway of 'regen1 Asbestos f/cc 0.02 2.0 Less than (<) values indicated that contaminant concentrations were below the reliable level of quantification of the method of analysis. The TLV for Dust that contains >1% quartz is calculated as follows: TLV for Total Dust=(30 mg/M")/(% quartz O) This TLV is recommended by the ACGIH in their Documentation for Threshold Limit Values for total dust samples containing Quartz. LAM 023925 -5 - ABS-007107