Document 5L038NJXroMdrXXMMXwDzKNp4

UC -4B-a INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION 270 PARK AVENUE, NEW YORK, NEW YORK 10017 To fWomW Dnrisfat lfraction '-cm Mr. F. H. Larrlson Mining & Metals Division P. 0. Box K King City, California Dot. Orlplimftftp Amwarfng lHc Ml January 17, 1972 Mr. E. A. Piersa.il Mr. J. W. Rawlines Dr. J. J. Welsh/Dr. K. S. Lane Sb|*d \ Dear Mr. Larrlsont' The findings for dust determinations I made at King City, January 4, 5, 1972, are given below. They were evaluated in accordance with the techniques recommended in OSHA regulations. ( Fibers/ml 5 . microns or more Total Location and Operationin length duat/ml Bagging Area Inside hard top hood (white cap) worn by bagger operator bagging. Super Vesbestos. 1.0 2.0 1.5 1.0 4 6 4 3 General area from bagger to palletizer during same period. 20 41 59 88 Inside hard top hood while bagging RG210 (bags broken - much dust). 1.4 4 Inside flexible hood (white cap) worn by bagger operator bagging RG210. 3.8 10 General area from bagger to pelletizer during same period. White Cap air supply (white cap pump, etc.). 45 39 1 1 79 65 2.5 2.0 d &fg.*A F f *' i O| jxttfp <G72 UCC 015379 Mr. F. H. Larrlson -2- January 17, 1972 Location and Operation______ FiberB/ml 5 microns or more in length Total dust/ml Outside - Clear, Cold Day Very little wind. At air compressor Intake. 4 16 r5 19 - Ground level directly below bag filter discharge. South fence line. 3 20 4 14 n 2 14 Beside cat operator dressing ore pile (wet ore). 1.5 7 1.4 7 Beside loader-carrier operator handling tailings (wet materials). 1.5 1.0 8 8 Wet Circuit Area Ground floor - general. 2 ' 12 3 14' Rock fiber - Control panel deck above filter presses^ 3 25 Shaker table area. 3 21 During this period a very limited attempt was made to determine the amount of solid effluents emitted by the two drier stacks. Sample collection was greatly limited by pump capacity, filter paper durability, stack temperatures, and the high water content of the gases. As a result we could only make a crude estimate of stack effluents, but for both > cases the solid content appeared to be of the order of 0.04 - 0.08 grains/ std. cubic foot. Microscopic examination of tha samples showed many fibers with too much overlap to be counted. Obviously, for accurate measurement UCC 015380 Mr. F. H. Larrlson -3 January 17, 1972 of stack discharge, different sampling equipment and techniques vlll be needed. Very truly yours, C PMMp Paul V. McDaniel Industrial Hygiene Engineer \ \ V' UCC 015381