Document 5L038NJXroMdrXXMMXwDzKNp4
UC -4B-a
INTERNAL CORRESPONDENCE
UNION CARBIDE CORPORATION
270 PARK AVENUE, NEW YORK, NEW YORK 10017
To fWomW Dnrisfat lfraction
'-cm
Mr. F. H. Larrlson Mining & Metals Division P. 0. Box K King City, California
Dot. Orlplimftftp
Amwarfng lHc Ml
January 17, 1972
Mr. E. A. Piersa.il Mr. J. W. Rawlines Dr. J. J. Welsh/Dr. K. S. Lane
Sb|*d
\
Dear Mr. Larrlsont'
The findings for dust determinations I made at King City,
January 4, 5, 1972, are given below. They were evaluated in accordance
with the techniques recommended in OSHA regulations.
(
Fibers/ml 5 . microns or more Total Location and Operationin length duat/ml
Bagging Area Inside hard top hood (white cap) worn by bagger operator bagging. Super Vesbestos.
1.0 2.0 1.5 1.0
4 6 4 3
General area from bagger to palletizer during same period.
20 41
59 88
Inside hard top hood while bagging RG210 (bags broken - much dust).
1.4
4
Inside flexible hood (white cap) worn by bagger operator bagging RG210.
3.8
10
General area from bagger to pelletizer during same period.
White Cap air supply (white cap pump, etc.).
45 39
1 1
79 65
2.5 2.0
d &fg.*A F f
*'
i O|
jxttfp <G72
UCC 015379
Mr. F. H. Larrlson
-2- January 17, 1972
Location and Operation______
FiberB/ml 5 microns or more in length
Total dust/ml
Outside - Clear, Cold Day Very little wind.
At air compressor Intake.
4 16 r5 19 -
Ground level directly below bag filter discharge.
South fence line.
3 20 4 14
n
2 14
Beside cat operator dressing ore pile (wet ore).
1.5 7 1.4 7
Beside loader-carrier operator handling tailings (wet materials).
1.5 1.0
8 8
Wet Circuit Area Ground floor - general.
2 ' 12 3 14'
Rock fiber - Control panel deck above filter presses^
3
25
Shaker table area.
3 21
During this period a very limited attempt was made to determine the amount of solid effluents emitted by the two drier stacks. Sample collection was greatly limited by pump capacity, filter paper durability, stack temperatures, and the high water content of the gases. As a result we could only make a crude estimate of stack effluents, but for both > cases the solid content appeared to be of the order of 0.04 - 0.08 grains/ std. cubic foot. Microscopic examination of tha samples showed many fibers with too much overlap to be counted. Obviously, for accurate measurement
UCC 015380
Mr. F. H. Larrlson
-3 January 17, 1972
of stack discharge, different sampling equipment and techniques vlll be needed.
Very truly yours, C
PMMp
Paul V. McDaniel Industrial Hygiene Engineer
\
\
V'
UCC 015381