Document 5Dwgbeno6GGKNJdG1x8pe2z28

174 CHAPTER 9 1950 Guide Table 2. Conductivities (fc) and Conductances (C) of Building and Insulating Matebials--Continued These constant* are expressed in Btu per (hour) (sqttarefoct) (Fahrenheit decree temperature difference). Conductivities (A) are per inch thickness and conductances (C) are for thickness or construction stated, not per inch thickness. Material MASONRY MATERIAL --(Continued) Concrete--(Continued).. 8 In. Concrete Blocks llllltXK Description Densin (Lb pee Mean Temp Co Ft) Deo) CoNDCcnvrrr Conductance ( (O Resistance " Per Inch For u Thickness Thickness Listed b (t) (*) l < Expanded vermicuHte aggregate__ Expanded vermiculite aggregate..... Concrete plank__ ,,...__ Cellulargnnerete ... , ... Cellular concrete__--_____ _.__ Cellular concrete_________....__ __ Cellular concrete......____ ______ 35 50 76 40.0 50.0 60.0 70.0 90 90 75 75 75 75 75 0.86 1.10 2.5 1.06 1.44 1.80 2.18 ... 1.16 0.91 0-40 0.94 0.69 0.56 0.46 8 In. three oral core, sand and gravel aggregate--................... -..... -......... ....... 126.4 40 0.90 8 in. three oval core, crushed limestone aggregate*........................ ....................... 134.3 40 0.86 8 in. three oval core, cinder aggregate*...... 864 40 ....... 043 -- S in. three oval core, burned clay aggre gate2...... ....... ,,.............. -...........-...... ,,.. 67.7 40 -- 04G -- 8 in. three oval core, expanded blast furnace slag aggregate*__ _____ --____ -- 40 -- 0.49 -- (3) (3) -- (3) (3) (3) 1.11 1.16 1.73 2.00 2.04 (4) (4) (4) (4) (4) 12 In. Concrete Blocks lilIiUMmiMMiMilk 12 In. three ova core, sand and gravel aggregate*.......- ------- ---------...--...... -12 in. three oval core, cinder aggregate* ... 12 in. three oval core, burned day aggregate*....--------------------_________ 124.9 86.2 76.7 40 0.78 40 -- 043 -- 40 0.47 1.28 148 2.13 (4) (4) (4) Gypsum-... 3 in. solid gypsum partition tile*...... ........ 3 in. three cell gypsum partition tile*___ 4 in. three cell gypsum partition tile*--. 87^ per cent gypsum, 12^ per cent wood chips__________________ _________ ___ Gypsum plaster--_______ ,--________ -- 51.2 74 2.41 1.66 3.30 0.74 0.60 0.42 -- 0.60 0.30 PLASTERING MATERIALS Gypsum plaster, Ys in. thkk._______ __ 73 8.80 Cement plaster___ -- -- 8.00 0.13 Wood, lath and plaster, total thickness 70 -- 240 -- Gypsum plaster and expanded verml- culite, 4 to 1 mix___ .._______________ 39.9 75 0.85 ... 1.18 Insulating plaster 0.9 in. thick applied to H in- gypsum board____ ..__ _________ 54.0 75 1.07 -- ROOFING Asbestos ahinglea.................. ........... . 65.0 75 6.0 Asphalt, composition or prepared...... ..... 70.0 75 6.5 Asphalt shingles. 70.0 75 -- 6.5 -- Built-up roofing, bitumen or felt, gravel or slag surfaced*_,,___________ 1.33 0.75 Slate........................ ...... ....................... ..... 10.00 0.10 Wood shinies.--___ .___ _____ _________ -- ...... 1.28 -- WOODS Balsa-- Balsa.... __________ _______....____ Balsa___ -. ____________ _____ ____.-___ __ California redwood, 0 per cent moisture*.... Cyprees------- ----- ----------------- --------------------- Douglas fir, 0 per cent moisture*_______ Eastern hemlock, 0 per cent moisture*__ Long leafyellow {fine, 0 per cent moisture* Mahogany.. --. ............. ....... , 20.0 8.3 74 28.0 28.7 34.0 30.0 40.0 34.3 90 90 90 75 86 75 75 75 86 0.58 0.38 0.33 0.70 0.67 0.57 0.76 0.86 0.90 ... 1.72 2.63 3.03 1.43 1.49 1.49 142 1.16 1.11 U5 1.67 -- (4) 14) (4) (4) 0.11 -- ((24)) 0.40 (4> -- (3) 0.93 (3) 0.17 0.15 0.15 0.78 (3) (3) (3) (2) uin> (1) (4) _____ (1) (4) i(n4) --n Sm footnotes on first page of Table 2. Heat Transmission Coefficients of Building Materials 175 Table 2. Conductivities (fc) and Conductances (C) op Building and Insulating Materials--Continued flat constants ore expressed in Btu per (hour) (square foot) (Fahrenheit decree temperature difference). . P-- . ..... /I , _ . .. . I . I I- -- ... --J I I "I MW, A, Material ffOODS--(Continued) Description Densitt (La veb Cu Ft) Mean Temp (Fahb Deg) Conductrvitt OB Conductance (i) (C) Resistance Per Inch Thickness For Thlckoces listed (1) (i) X < Hard maple, 0 per cent moisture*.....--___ Maple, across graia------------..------------- --. Norway pine, 0 per cent moisture*.--___ Red cypress, 0 per cent moisture-.--___ Red cat. 0 per cent moisture*......... ........... Short leaf yellow pine, 0 per cent moisture* Soft elm, 0 per cent moisture-___________ Soft maple, 0 per ceDt moisture-_________ Virginia pine.............................................. --. West coast hemlock, 0 per cent moisture* White pine...........-................... _......... . ..... Yellow pine....................--........... ................. Shavings, various from planer..................... Shavings, from maple beech and birch 46.0 44.3 40.0 32.0 32.0 48.0 36.0 34.0 42.0 28.0 34.3 30.0 31.2 12.0 8.8 13.2 75 86 75 75 75 75 75 75 75 75 86 75 85 90 90 90 1.05 M0 1.20 0.74 0.79 1.18 0.91 0.88 0.95 0.64 0.96 0.79 0.78 1.00 0.4! 0.41 0.36 i i 1 ! i ! i M ! M i ! ].! i 0.95 (4) 0.91 (1) j0.83 145 147 0.85 1.10 1.14 1.05 146 1.04 1.27 1.28 (3) <<> (4) (4) (4) (4) (4) (4) (D (4) 0) 1.00 (3) 2.44 0) 2.44 (1) 2.78 (1) INSULATING MATERIALS Chemically treated wood fibers held Eel grass between strong paper.......... ........ Ed grass between strong paper........ .......... Flax fibers between strong paper................ Chemically treated hog hair between kraft paper-..................-............................. Chemically treated hog hair between kraft paper and csbcstcs paper............... Hair felt between layers of paper- ........ Kapok between burlap or paper-........... .. Stitched and creped expanding fibrous blanket........................................... .............. Paper and asbestos fiber with emulsified asphalt binder............................................. Cotton insulating bat.__ --____ __ ____..... 3.62 4.60 3.40 4.90 70 90 90 90 5.76 71 7.70 11.00 2.00 71 75 90 1.50 70 4.2 ^94 .0.875 72 Short Staple Linters, Fireproofed........... Short Staple Linters, Fireproofed--....... Short Staple Lmtcrs, f ireproofed.......... Short Staple Linters, Fireproofed........... Short Staple Lictcrs, Fireproofed..--..... Short Staple Linters, Fireproofed........... Felted cattle hair................................. --... Feitcd cattle hair.......................... --. . Felted hair and asbestos_____ ____ _______ Ground paper between two layers, each H in. thick made up of two layers of kraft paoer (sample Y in. thick)__--___ Mineral Wool.............-........... .......... -- 6.25 4.50 2.45 1.60 0.85 0.65 13.00 11.00 7.80 90 SO . 90 90 90 90 90 90 90 12.1 75 4.5 - 0.25 0.26 0.25 0.28 0.26 0.28 0.25 0.24 0.27 0.28 0.24 0.25 0.24 0.24 0.26 0.29 040 0.25 0.26 0.28 __ .. -- __ -- -- __ 4.00 3.85 4.00 347 3.85 347 4.00 4.17 3.70 347 4.17 4.00 4.17 4.17 3.85 3.45 343 3.84 344 347 ____ 0.27 0.40 ~ 3.70 RETLEcnva. --.............. ..... See Table 1, Section C--.............-- __ -- ... -- ... -- , ___ ___ ' ___ ____ __ _ (3) (1) (1) (U (3) (3) (3) (1) (3) <1> 13) (1) (1) (!) (1) (11 (1) (1) (1) (1) 240 -- (4) Insulating Board............... Made from sugar cane fiber...... __________ Made from corn stalks ................ --...___ Made from exploded wood fibers....._____ Mode from wood fiber................. ............. --. Made from wood fiber............. ................-- Made from wood fiber_________ __________ Made from wood fiber............... --..... --_ Made from wood fiber.....--............ ............ 13.5 15.03 17.90 15.20 15.30 15.00 840 15.20 16.90 70 . 71 78 70 72 70 52 72 30 043 043 047 042 043 0.33 043 0.29 043 0.34 -- __ " 3.03 3.03 3.12 3 2 3.03 3.03 3.03 3.45 3.03 2.94 __ _ . ----- (3) (3) (4) (3) (3) <3) m(6) (3) ID See footnotes on first page of Table 2,