Document 5Dd8gpv1yww0q1jz9yr1Rqvp5

740 CHAPTER 28 19587 Guide equipped with a thermostatic air vent and the condensate .shQuld.be per mitted to flow by gravity through the economizer and meter. METERING The Condensate Meter was developed for the district heating industry and is an approved method of measuring condensate where all of it can be brought to a common point for metering purposes. Its simplicity of de sign, ease in testing, accuracy at all loads, low cost, and adaptability to Motes Capacity Lb Peb Hb 250 500 Diagram B............................... 4 4 Diagram C............................... 12 12 Diagram D................ .............. 12 . 12 750 1500 3000 A--'Dimension Inches 888 15 15 15 15 15 15 6500 12 ' 18 18 Fig. 6. Condensate Meteb Installation Details 12000 12 18 18 either high- or low-pressure distribution have made it standard equipment with most heating companies. Condensate meters must not be operated under pressure; they are made for either gravity or vacuum installations. Typical meter installa tions are shown in Fig. 6. In diagram A a continuous-flow type trap is shown installed ahead of the meter, while in diagram B an intermittent type trap is used. In the latter case, a receiving tank must be placed be tween the trap and meter to prevent intermittent overloading of the meter. When measuring the discharge from a vacuum pump, a vented receiver should always be installed ahead of the meter. . Installations of meters in a. vacuum return line are shown in diagrams C and D. In diagram C a master, continuous-flow trap is installed im mediately ahead of the meter to prevent steam from entering it in case of District Heating 741 leaking radiator or fixture traps. Where individual traps are reliable; con nections may be made as shown in diagram D. Flow meters are generally used for measuring sendout from plants, highpressure requirements in buildings, and in installations where all.of the condensate cannot be returned to a central point. Further information on flow meters is available from publications of the FluidMeter committee of the American Society ofMechanical Engineers the District Heating Hand book,TM and are described in Chapter 4. HOT WATER DISTRIBUTION District heating in the United States is confined almost entirely to the use of steam as the heating medium. Hot water has been used and is being used today, where economic conditions are favorable and good engineering practice dictates. The use of low-pressure hot water distribution below 200 F has been practically discontinued for district heating in the United States because of practical and economic difficulties. The use of high-pressure, high-temper ature water distribution at 275 to 400 F has found favor in Europe, where fuel is scarce and is finding some application in the United States.24 High-pressure water distribution has some practical and economic ad vantages over steam (see Section on High TemperatureWater System in Chapter 21). Higher thermal efficiencies, better daily and annual system load factors, lower water treatment costs, smaller pipe sizes, fewer piping accessories, and feasibility of installing pipe to follow contour of ground are given as a few. On the other hand hot water requires a two-pipe distribu tion system increasing the capital investment in some cases and system maintenance is complicated by the necessity to drain at least a portion of the system when connections are made or leaks repaired. The advantages of hot water have overcome the disadvantages in some industrial applications and in air force bases in this country. As the cost of fuel increases, additional applications will probably become practicable, especially in new installations serving buildings designed for hot water heating.1 REFERENCES . `Recent Developments in High Temperature Water for Area Heat Distribution in the United States, by Paul L. Geiringer (Proceedings, National District Heating Association, 1956). ' 1 Steam Requirements for Processes, Maximum Demand and Load Factor, District Heating Handbook, Third Edition, pp. 346-360 (National District Heating Association). .. 1 Influence of Pressure, District Heating Handbook, Third Edition, pp. 147-152 VNational District Heating Association), . 4 Effect of Looping, District Healing Handbook, Third Edition, pp. 155-158 (Na tional District Heating Association). gra5pvh^4n08",0-p*.116S6 t(aAnmdaerrdicaCnodSeocfoiertyPorefsMsuercehaPnipicianlgE, nAgSinAeBers3)1. .1, 1955, Section 4, para Steam Pressure Boosters, District Heating Handbook, Third Edition, pp. 329-332. 'National District Heating Association). it 7 praPhical Solution of Unwin's Formula (a chart published by National District eating Association). Explanation of chart, District Heating Handbook, Third Edion, p. 194 (National District Heating Association.) ,p Improved Method of Supporting Steam Pipes in Tunnels, by Gordon Carlson ' tceedmg8, National District Heating Association, 1955, p. 125). Am ^'strict Heating Piping Systems, Section 4 and Fabrication Details, Section 6, A m!H-Caa Standard Code for Pressure Piping ASA B31.1, 1955 (Published by the mean Society of Mechanical Engineers.)