Document 5DLqGaoDa8dZOvMGJ001jJJ0z

-- A?? ?-'' 11 \ f - l ^11 l TABLE OF CONTENTS ETndustriai linsulation PRODUCT PAGE Air Cell Pipe Covering & Block.......................... 17 Alltemp Pipe Covering...................................... 5-6 Alltemp Block.................................................... 7-8 Asbestos Millboard.............................................. 47 Asbestos Paper & Rollboard.............................. 45 Asbestos Sheets & Panels Asphalt Plyboard.......................................... 49 Careystone Corrugated...................................49 Firefoil Board................................................ 50 Industrial A-C Board.................................... 49 Thermo-Bord ................................................ 49 Asbestos Sponge Pipe & Block Insulation.......... 21 B.T.U. Cement.................................................... 42 Careycel Pipe & Block Insulation.................. 15-16 Careytemp Pipe & Block Insulation.................4-4A Cements Insulating & Finishing.................................. 37 Bonding & Refractory.................................. 38 Cork-Cote Mastic................................................ 40 Corrugated Asbestos Paper................................ 46 Defendex Pipe & Board Insulation...................... 19 PRODUCT PAGE Fireclad Jacketing.............................................. 43 Flexible Tubing Insulation.......... ....................... 22 Hair Felt Insulation............................................ 31 Hi-Temp #19 Block............................................ 9 Insulation Emulsions.......................................... 39 Insulation Seal.................................................... 41 Mineral Wool Industrial Blanket...................... 27 Mineral Wool Industrial Pipe Insulation.......... 29 MW-50 Insulating Cement................................ 33 MW-One Insulating Cement........................ 35-36 Spun Mineral Wool Duct Insulation...............51-52 Superbo Pipe Covering...................................14-14A Super-Light 85% Magnesia Pipe Covering.... 1-2 Super-Light 85% Magnesia Block...................... 3 Thermoglas Pipe Covering............................ 23-24 Thermoglas R/F Insulation.......................... 25-26 Weatherproof Jacketing Materials.................... 44 Woolfelt Pipe Covering Ferfecto.......................................................... 11 Impervo.......................................................... 12 Protecto.......................................................... 13 f \ SUPER-LIGHT 85% MAGNESIA PIPE COVERING 1 me - industrial insulation Conductivity (kV- At 100 F.r-.34 200 F.--.37 400 F.--.43 Moisture Absorption (volume)-- After 6 hours exposure in atmosphere of 120 F. and 90% relative humidity-- 0.9%. TABLE OF RECOMMENDED THICKNESSES Pipe Sites Temperature Range-- F 100 to 200 201 to 300 301 to 400 401 to 500 501 to 600 H" to Mi" 1" 1" 1" l-X" 2" 2" to 3-H" 1" 1" 1-K" 1-S" 2" 4" to e' i" l-K" 2" 2" 2-K" 7" to 10" 1-K" 1-H" 2-Y," 2-M" 3" 12" & Larger 1-M" o* 2-K" 3" 3" Super-Light "Nesting O.D." pipe sec tions, for temperatures from 100 F. to 600 F. DESCRIPTION Super-Light 85% Magnesia is composed of not less than 85% basic hydrated carbonate of magnesia, and 10% to 15% specially selected and prepared long asbestos fibers. Government Specifications: Super-Light 85% Magnesia meets these government specifications when orders specify this requirement. Federal HH-M-61a--Pipe Covering, Blocks and Cement (when ordered, special 3.5 canvas will be supplied to meet certain Federal Specifications.) M1L-P-2781B--Grade 1, Class b--Pipe Covering (Super-Light). Test Reference EES 1CCT411. Navy 21Yc--Pipe Covering and Blocks Navy 32P10B--Cement AMSC 35-Type H2 FEATURES Super-Light 85% Magnesia is strong, moisture resistant, shock resistant and smooth finished. It is a material with low conductivity and high dimensional stability. Super-Light Magnesia has no tendency to induce corrosion on metal surfaces to which it is applied as in sulation. Sections will not disintegrate, crack or crumble under normal service conditions...can be removed and re applied when necessary. Excellent workability makes Super-Light easy and economical to apply. USES Super-Light 85% Magnesia pipe covering is a practical, efficient insulation for almost every kind of hot-pipe application. It can be used directly on pipes operating at temperatures up to 600 F., or it can be used as an outer layer over Carey Alltemp where temperatures range from 600 F. to 1600 F. SPECIFICATIONS Density--Approximately 10-11 lbs. per cu. ft. Shrinkage-- 0.5% at 500 F. Boiler feed pump room of the Arapboe Station, Public Service Co. of Colorado in Denver. Feed water discharge lines and recirculating lines are insulated with 2" thick Carey 85% magnesia, Carey Industrial Insulation ' ''PLICATION anal pipe coverings are held in pjace by cementing the canvas laps with cold water paste, along lateral and abutting joints. As additional secure* ment, metal bands can be applied ap proximately 18" apart on butt joints and in the center o{ the section. Fittings up to 4" are usually insulated with 85% Magnesia Cement. Larger fittings are usually insulated with small pieces of Super-Light 85% Magnesia Block cemented with fibrous adhesive or secured with wires. Super-Light 85% Magnesia Cement or Carey No. 303 Asbestos Cement should be used to fill cracks at joints and create a smooth surface. steam line and turbine central -s at Jamestown, N.Y. power plant are insulated with Carey Super-Light 85% magnesia. ^ Super-Light 85% Magnesia Pipe Covering s v.. SUPER-LIGHT 85% MAGNESIA BLOCK (industrial (insulation Conductivity (k) -- At 100 F.--.33 200 F.--.36 400 F.--.43 Moisture Absorption (volume)-- After 6 hours exposure in atmosphere of 120 F. and 90% relative humidity 0.9%. Federal HH-M-61a -- Pipe Covering. Blocks and Cement. MIL-I-2819- Blocks Class a -- Filter Mold. Test Reference EES B-7571. Class a -- Super-Light. Test Reference EES 1DDT411. Super-Light block has smooth surface, uniform thickness and sharp, true edges. Makes tight, efficient joints. Super Light blocks can be used at temperatures up to 600 F. DESCRIPTION Super-Light is composed of not less than 85% basic hydrated carbonate of mag nesia, and 10% to 15% specially selected and prepared long asbestos fibers. FEATURES Super-Light 85% Magnesia is strong, moisture resistant, shock resistant and smooth finished. It is a material with low conductivity' and high dimensional stability. Super-Light Magnesia has no tendency to induce corrosion on metal surfaces to which it is applied as insula tion. Blocks will not disintegrate, crack or crumble under normal service con ditions....can be removed and reapplied when necessary. Excellent workability makes Super-Light easy and economical to apply. After being boiled in water for 24 hours, Super-Light 85% Magnesia shows no evi dence of disintegration or change in shape. Water test reveals unusual stabi lity of Super-Light's chemically "set" monolithic structure. Navy 21 Yc -- Pipe Covering and Blocks. Navy 32P10B -- Cement AMSC 35 - Type H2 APPLICATION RECOMMENDED THICKNESS TABLE Temp. Range -- Recommended F. Thickness--In. 100 to 201 to 301 to 401 to 200 300 400 600 W/t 2 2-'/i 3 Sizes: Super-Light block is available in the standard size, 6" wide by 36" long, in thicknesses of 1", V/i", 1|4", 2", 2'/," and 3". * Government Specifications: Super-Light 85% Magnesia block meets these govern ment specifications when orders specify this requirement. Super-Light 85% Magnesia blocks are usually held in place with No. 14 or No. 16 Gauge wire spaced approximately 12" apart. Joints are pointed up with 85% Magnesia or Carey Asbestos Cement. As additional securement, Carey Fibrous Adhesive can be usedto adhere blocks to surfaces. Hexagonal wire mesh (l|.j") is stretched tight over the blocks as a reinforcement for the finish coat of asbestos cement, approximately thick. Segmental blocks, for covering large pipes, are applied with No. 16 steel wire loops spaced approximately 12" apart. Loops are pulled tight and imbedded in the surface of the covering. Canvas jackets are then pasted on. Application of metal bands is optional. USES Super-Light 85% Magnesia block is an efficient insulation for all types of heated equipment in power plants and process industries. It is used on boilers, tanks, kilns, ovens and other equipment having temperatures up to 600 F.; or, it can be used as an outer layer over Carey Alltemp where temperatures range from 600 F. to 1600 F. SPECIFICATIONS Density -- Approximately 10 to 11 lbs. per cu. ft. Flexural Strength -- 40 to 50 ibs. per sq. in. modulus. Compressive Strength (at 5% deformation! 60-65 lbs. per sq. in. Impact Strength (blocks 6" wide by 1-K" thick) - 15 ft. lbs. Shrinlege - 0.5% at 500F. CAREYTEMP PIPE AND BLOCK industrial 'insulation Careytemp can be cat cracker-thin without crumbling. Doe to precision molding process, edges are neat and square provid ing tight joints. Careytemp requires no special tools, saves time and costs, simplifies plant clean-up* Careytemp's exceptional strength and light weight reduces application costs on every job. Analytical balance shows that block of Careytemp, cut to exact dimensions of regularsize cigarette package, weighs as little as 10 cigarettes. DESCRIPTION Careytemp is an exceptionally strong, light weight insulation made in both block and pipe form. It is composed of expanded perlite ore, reinforced with an inorganic fibre and with a binder developed especially for this insulation product. The expanded silica (perlite) is an inorganic cellular body consisting of millions of individual vitrified (glassed-in) air ceils which retain their structure permanently and thereby resist water penetration. Careytemp is recommended for tempera tures up to 1600^F; thermal conductivity over the entire range is extremely low. This insulation exhibits a high degree of resistance to acids and to corrosion. USES Careytemp pipe and block insulation is recommended for all types of installa tions with operating temperatures up to 1600F. With the addition of suitable vapor barriers it can be used on equip ment or piping operating at sub-zero temperatures. Careytemp will not contribute to the stress corrosion cracking of austenitic stainless steel, in acid resistance tests Careytemp has withstood complete im mersion in both 25% solutions and con centrated aqua regia, hydrochloric and sulfuric acids for 100 hours. Due to the combination of light weight. low thermal conductivity and low mois ture absorption, Careytemp is particularly suitable for process industry and power plant applications. APPLICATION Careytemp is applied accordingto stand ard insulation industry methods and practices. No special tools or equipment are required. Standard thicknesses or built-up multiple layers can be applied. Due to extremely low moisture absorption, the use of nonbydraulic setting cements with Carey temp is not recommended. Mineral wool cements provide a superior, rigid cement finish. Carey MW-50 or MW-one are recom mended. Sizes: Pipe insolation is presently available in all copper tube sizes through 3** and in iron pipe sizes through 6**. Block is available in widths of 6*' and 12", in thicknesses from 1*' through 3'* and in lengths of 18" and 36". A cixrent established program to provide sectional pipe insulation through 26*' IPS will be completed in the near future. Jackets: Standard canvas, heavy weight canvas and weatherproof roofing jackets are available. SPECIFICATIONS Density: 9 lbs. per cu. ft. Transverse Strength: 70 lbs. per sq. in. Compressive Strength: 65 lbs. per sq. in. (with 1% deformation) Linear Shrinkage: .7% at 1200F. 1.2% at 1500F. Water Absorption: .2% in 24 hours at 90% R.H. Thermal Shock: Hot and cold cycle test, 400 to 15F., no damage. When immersed in liquid Nitrogen at minus 325F., so damage. Acid Resistance: When immersed in sul phuric, hydrochloric acid or aqua regia, no damage in 100 hours. Corrosion Resistance: Non-corrosive. Composed of chemically inert material. Temperature Range: Up to 1600F. Thermal CONOUCTiviTr l. 1 1 iH j 1 i , -] 1- ; i ; i | -rl 1 : I --hr Mi -- -J--------l--i-l. | | T| 11 m ;' H--i ; i 1 ! ! i rrrr 1 ! M ii ' H ! i i>^! i : --Tl , 11 III! !: i ~t ! ! 1 ii> 11 ' : : 1 ! 1" i : 1 : ? ->< . i 1 1 , ( Jr* \ 1 1 1 i j:.i!; !!|11. zn:Ill' T 1 1 1 1 ' 1 * > I 1 *! '` `' Ii 11 '1 1 i , ioe ;oo joo oo wo too ?ac aoc oe >oec MEAN TEMPERATURE '( Carey Industrial Insulation Careytemp Pipe and Block DATA* USING RECOMMENDED THICKNESSES Pipe Temp. Temp F. Diff. 380 300 Recom'd Thk. Btu Loss Surface Temp. F. % Efficiency 580 500 Recom'd. Thk. Btu Loss Surface Temp. F. % Efficiency 780 700 Recom'd Thk. Btu Loss Surface Temp. F. % Efficiency 880 800 Recom'd. Thk* Btu Loss Surface Temp. F. % Efficiency 1080 1000 Recom'd. Thk. Btu Loss Surface Temp. F. % Efficiency 1280 1200 Recom'd. Thk. Btu Loss Surface Temp. F. % Efficiency Careytemp Pipe Size 80F. Air 1* 3* 4' 6' 8' 10' 12' 18' V 1' 85 115 122 125 86.8 87.6 1*4' 103 111 91.2 1*4' 143 115 91.5 1*4' 174 115 91.9 2' 165 108 93.8 2' 193 109 93.8 2' 274 112 93.7 1*4' 122 128 92.1 r 134 120 94.0 2' 160 122 94.4 2*4' 184 117 95.5 2*4' 216 117 95.9 2*4' 263 119 96.0 3' 265 113 96.5 3' 369 118 96.5 2*4' 143 122 95.2 2*4' 181 127 95.8 3' 191 121 96.6 r 252 125 96.9 3*4' 270 120 97.4 3*4' 322 122 97.5 3*4' 368 124 97.6 3V4' 506 128 97.6 2*4' 170 129 95.8 3" 197 126 96.6 3* 229 128 96.9 3*4' 268 125 97.5 3*4' 324 127 97.7 4' 353 124 98.0 4' 399 126 98.0 4' 546 130 98.0 2*4' 235 145 96.5 3" 270 142 97.2 3*4' 288 134 97.7 4' 339 131 98.1 4' 406 134 98.5 4*4' 432 130 98.5 4*4' 506 133 98.5 4*4' 682 138 98.6 3279 149 96.9 3*4' 335 143 97.8 4' 347 141 98.3 4*4' 416 139 98.6 4*4' 494 143 98.7 5' 546 139 98.8 5' 595 139 98.9 5*4' 750 141 99.0 *Btu Losses are per Linear Ft. DATA FOR CAREYTEMP BLOCK Inner Surface Temperature F. 1' 1*4' Insulation Thickness 2' 2*4' 3' 3*4' 80F. Air. 4' 4*4' 5' 5*4' Btu Loss 380 Sur. Temp. F. % Efficiency 98 134 90.1 69 120 93.0 -53 112 94.6 42 106 95.8 35 102 96.5 31 100 96.9 Btu Loss 580 Sur. Temp. F. % Efficiency 184 171 92.3 126 147 94.7 98 134 95.9 81 126 96.6 67 119 97.2 57 114 97.6 49 110 97.8 44 107 98.1 40 106 98.3 38 104 98.4 Btu Loss 780 Sur. Temp. F. % Efficiency 200 177 95.7 152 158 96.8 125 146 97.3 106 136 97.7 91 130 98.0 -79 124 98.3 70 120 98.5 63 117 98.6 58 115 98.7 Btu Loss 880 Sur. Temp. F. % Efficiency 185 171 97.1 148 157 97.6 126 146 98.0 108 139 98.3 95 132 98.5 84 128 98.6 76 124 98.8 70 121 98.9 Btu Loss 1080 Sur. Temp. F. % Efficiency 206 179 98.1 172 166 98.4 149 156 98.6 132 148 98.7 117 -106 142 136 98.9 99.0 97 133 99.0 Btu Loss 1280 Sur. Temp. F. % Efficiency 226 186 98.7 195 175 98.8 172 166 99.0 153 158 99.1 138 -126 151 146 99.2 99.3 *Btu losses are per hour per square foot Indicates recommended thickness. ALLTEMP PIPE COVERING [industrial Insulation ant, extremely durable and will with stand packing, shipping and handling with little, if any, breakage. It does not cut, scratch or otherwise irritate appli cators* hands and skin. USES broken-joint double-layer construction. It can also be installed as an inner lave: in combination with an outer layer of Super-Light Magnesia. In combination in sulation, Alltemp absorbs the initial heat shock of high temperature piping anc brings the temperature down to the safe limit of the outer-layer insulation. Alltemp Pipe Covering is recommended for all temperatures from 100 F, to 1600 F. It is particularly recommended for irregular surfaces, as well as valves and fittings. Sizes: Alltemp sectional pipe covering is available through 12**; tri-sections and quad-sections available in larger sizes. "Nesting O.D.** pipe covering sizes pro vide accurate tight fits over or into an APPLICATION other size. This permits a wide range of assemblies and gives the advantage of building up many thicknesses from a Alltemp is applied in single-layer or limited number of prime units. r X Alltemp Pipe Covering is an all-purpose insulation for temperatures from 10(r F. to 1600 F. DESCRIPTION Alltemp is a combination of special in organic silicas and asbestos fibres. Every cubic foot is honeycombed with millions of tiny sealed air cells. Having excellent physical and chemical proper ties, Alltemp retains its high thermal efficiency 'and structural strength even when subjected to long and continuous exposure to high temperatures and moist ure. FEATURES Alltemp is recommended for high-temperature or low-temperature piping systems. Extremely low thermal conductivity-- actually improves after exposure to high temperatures. Full temperature range--from 100 F. to 1600 F. Low internal shrinkage--lowest of all tested comparable insulations ... approxi mately 40% of most 1200 F. insulations. Alltemp retains high efficiency because it does not crack or open up from shrink age. Moisture resistance--exposure to high moisture conditions does not deteriorate Alltemp or affect its thermal conductivity. Easily fitted--workmen can cut and trim Alltemp with a knife, even through can vas covering. They can trim closer and make a truer cut than with other insula tion materials. Edges remain neat and square ... make tight, "no-heat-leaking" joints. It is not brittle ... can be cut or shaped to fit irregular areas and around projections. Easily handled--Alltemp is shock resist- SPECIFICATIONS TABLE OF NOMINAL THICKNESSES, IN INCHES Nominal Temperature Difference Inches 200 300 400 500 600 700 800 900 1000 1100 1200 1-54 & Under 2 2-54 3 3-54 4 4-54 5 6 7 8 9 10 11 12 14 & Over i 11 1 1-54 1-54 2 2 2-54 2-54 11 1-54 1-54 2 2-54 2-54 2-54 2-54 11 1-54 2 2 2-54 2-54 3 3 11 1-54 2 2 2-54 3 3 3 1 1-54 1-54 2 2 2-54 3 3 3-54 1 1-54 1-54 2 2-54 3 3 3 3-54 1-54 1-54 2 2 2-54 3 3 3-54 3-54 1-54 1-54 2 2 2-54 3 3 3-54 3-54 1-54 1-55 2 2-54 2-54 3 3-54 3-54 4 1-54 1-54 2 2-54 2-54 3-54 3-54 4 4 1-54 1-54 2 2-54 3 3-54 3-54 4 4 1-54 1-54 2 2-54 3 3-54 3-54 4 4-54 1*54 2 2-54 2-54 3 3-54 4 4 4-54 1-54 2 2-54 3 3 3-54 4 4 4-54 1-54 2 2-54 3 3 3-54 4 4-54 4-54 1-54 2 i i 2-54 i 3 i 3-54 i 3-54 i 4 i 4-54 i 4-54 2-54 3 3 3-54 3-54 3-54 4 4 4 4-54 4-54 4-54 S 5 S imperatures above 1200, consult the Plymouth Meeting Office for nmendations. 3 3 3-54 3-54 4 4 4 4-54 4-54 4-54 5 5 5 5 5-54 Corey Industrial Insulation Alltemp Pipe Covering * FOR COMBINATION INSULATION OF ALLTEMP INNER LAYER AND SUPER-LIGHT 8S% MAGNESIA OUTER LAYER Pipe Temp, of 600 700 ,00 ( 900 00 1100 * 1200 Pipe Size- Inches 1 2 4 6 8 10 12 Reeom'd Thk. (Alltemp Inches (Super-Light BTU Loss Surface Temp.-- F. % Efficiency 2" None 98 118 89.6 1-HM r in 116 93.3 w r* 146 112 95.2 W \w 190 116 95.7 l-hM W 196 111 96.5 W 1-H" 270 120 96.1 1-H" W 304 120 96.3 Reeom'd Thk. (Alltemp Inches (Super-Light BTU Loss Surfoce Temp.-- F. % Efficiency 2" None 126 126 90.6 1-h" r* 127 114 94.6 W W 184 119 95.7 w W 239 124 96.2 !%" W 286 125 96.4 W 1-H" 341 128 96.6 W 2" 339 122 97.1 Reeom'd Thk. (Alltemp Inches (Super-Light 'BTU Loss ,, Surface Temp.-- F. % Efficiency 2" None 154 133 91.5 W4" l-H" 154 121 95.2 1-H" W 222 126 96.2 1-H" 2** 246 123 97.1 1*H" 2" 295 125 97.3 H4M 2" 363 129 97.3 W MS" 364 123 97.7 Reeom'd Thk. (Alltemp Inehes (Super-Light 'BTU Loss ,, Surface Temp.-- F. % Efficiency 2*' None 182 141 92.4 1W 179 127 95.7 W W 260 134 96.7 2" 2" 274 123 97.6 2*' 2" 330 127 97.7 2*' 2" 388 129 97.8 2" 2" 457 132 97.9 Reeom'd Thk. (Alltemp Inches (Super-Light 'BTU Loss ,, Surface Temp.-- F. % Efficiency 2" None 210 149 93.2 1-J4" 1-J4" 205 134 96.3 2" W 276 133 97.3 2-H" W 332 132 97.7 2" 363 129 98.1 to 2-H" 2" 422 131 98.2 3 1-tt" 491 132 98.3 Reeom'd Thk. (Alltemp Inches (Super-Light *BTU Loss ^ Surface Temp-- F. % Efficiency Reeom'd Thk. (Alltemp -Inehes (Super-L ight BTU Loss _ Surfoce 1 emp.-- F. % Efficiency ' 2" None 238 156 94.0 2" None 266 164 94.7 2M 1-fc" 223 133 96.8 y 1-H" 254 138 97.1 2-fc" W 295 132 97.7 3*' w 315 131 98.1 3" 2" 329 127 98.3 3-%" 1-H" 383 133 98.4 3" 2" 388 129 98.4 3*M>" H*" 451 136 98.5 3" 2" 461 132 98.5 W w 540 140 98.6 3-J4" W 533 135 98.5 w l-H" 600 141 98.7 *BTIJ Losses Are Per Lineal Ft. Per Hr. 80 Ambient Air Temperature No Interface Temperature Exceeds 575 F. Performance Data For Other Thicknesses See Bulletin 101 BX Alt Recommended Thicknesses Are Nominal 14 16 1-h" W 340 122 96.2 1-J4" 1-H" 390 124 96.2 W 2" 384 124 97.0 1-J4" 2" 419 125 97.1 2" 2" 421 126 97.6 2" 2*' 452 127 97.7 2-V W 498 135 97.9 2-fc" 1-14" 557 136 97.9 3" W 544 136 98.2 3" 1-tt" 586 137 98.3 3-J4" w* 580 138 98.5 3-J4" 1-JS" 628 139 98.6 3-%" l-fc" 656 144 98.7 3-fc" I-fc" 724 146 98.7 18 Hi" i-hM 438 125 96.2 W 2" 457 126 97.2 2" 2" 495 128 97.8 2-fc" W' 603 137 98.0 3" W 641 138 98.4 3-ttM w 693 140 98.6 3-V4" 1-h" 787 147 98.8 Alltemp is easy to handle, easy to fit ... saves time and labor costs. ALLTEMP BLOCK illll'IP i m i lindustrial linsulation USES APPLICATION Alltemp Block is recommended for high temperature* surfaces such as oil stills, ovens, boiler walls, breechings, fur naces and other equipment whose sur faces are between 100 F. and 1600 F. Alltemp Block is available for flat and curved surfaces. It is particularly recoin mended for irregular surfaces which re quire an easy-to-apply insulation. Alltemp Block can be applied as a com plete insulation or in combination with lower temperature insulations (such as Super-Light 85% Magnesia) to absorb initial heat shock. In combination insu lation, Alltemp reduces the temperature to the safe limit of the outer-layer insu lation. Alltemp block is an all-purpose insula tion within the temperature range of 100 F. to 1000 F. DESCRIPTION Alltemp is a combination of special in organic silicas and asbestos fibres. Every cubic foot is honeycombed with millions of tiny sealed air cells. Having excellent physical and chemical properties, All temp retains its high thermal efficiency and structural strength even when sub jected to long and continuous exposure to high temperatures and moisture. FEATURES Extremely low thermal conductivity-- actually improves after exposure to high temperatures. Full temperature range-- from 100 F. to 1600F. Low internal shrinkage--lowest of all tested comparable insulations. Alltemp re tains high efficiency because it does not crack or open up from shrinkage. Moisture resistance--exposure to high moisture conditions does not deteriorate Alltemp or affect its thermal conductivity. Easily fitted--workmen can cut and trim Ailtemp with a knife. They can trim clos er and make a truer cut than with other insulations. Edges remain neat and square ... make tight, "no-heat-leaking" joints. It is not brittle ... can be cut or shaped to fit irregular areas and around projec tions. Easily handled--Alltemp is shock resist ant, extremely durable and will withstand packing, shipping and handling with lit tle, if any, breakage. It will not cut, scratch or otherwise irritate applicators* bands and skin. SPECIFICATIONS Density--19-21 lbs.-per cu. ft. Conductivity--at 100 F....0.43 at 500 F....0.60 at 1000 F....0.72 Crushing strength (3% deformation) -- Cold ... approx. 58 lbs. per sq. in. 1500 F... approx. 60 lbs. per sq. in. Heat expansion--none Heat shrinkage--at 1200 F....0.72% at 1500 F....1.10* Flexural strength--60 lbs. per sq. in. Abrasion resistance -- Loss in 1st 10 min................................. 27% Loss in 20 min.........................................55% airduct. Packaging: Alltemp blocks are packed in cartons. The same carton packaging data shown under Filter Press 85% Magnesia Blocks also apply to Alltemp blocks ex cept that the weights are approximately 25% heavier. Carey Industrial Insulation Data for Combination Insulation of Alltemp Inner Layer and Super-Light 85% Magnesia Outer Layer Inner Surface Temperature0 F. 600 700 800 900 1000 1100 1200 Recom'd Thk. (Alltemp (Super-Light B IT Loss Per hq. Kt. Outer hurtace Temp.-- t. Efficiency--% i-vr i-ir 73 123 97.2 1-K" 2" 78 125 98.0 2" 2** 84 129 98.3 2-lj" Mr 102 135 98.4 3" l-'4" 108 139 98.7 Based on 80 Ambient Air Temperature No Interface Temperature Exceeds 565 Performance Data For Other Thicknesses See Bulletin 101BX 3-H" l-K" 111 139 99.0 4" 1-K" 116 L42 99.2 <jT 'deT D.V iter 34" 35" 36" 37" 38" 39" 40" 41" * * 45" 46" 47" 48" 49" 50" 51" 4r . o4" 55" 56" 57" 58" 59" 60" No. of 6" Ride Blocks To Cover 18 18 19 19 20 20 21 21 22 22 23 23 -24 24 25 25 26 26 27 28 28 29 29 30 30 31 31 3" Wide Filler Block 1 1 l 1 i 1 1 1 1 1 1 1 1 1 External Area Sq. Ft. Per 3 Ft. Length 2-*4" to 2" Thick Over 2" Thick 28.692 29.498 30.286 31.083 31.880 32.677 33.474 34.241 35.068 35.865 36.662 37.459 38.256 39.053 39.850 40.647 41.444 42.241 43.835 44.632 45.429 46.226 47.023 47.820 48.617 49.414 50.211 28.980 29.785 30.590 31.395 32.200 33.005 33.810 34.615 35.420 36.225 37.030 37.835 38.640 39.445 40.250 41.055 41.860 42.665 44.275 45.080 45.885 46.690 47.495 48.300 49.105 49.910 50.715 Alltemp Block HI-TEMP NO. 19 BLOCK industrial Einsulation APPLICATION SPECIFICATIONS Hi-Temp No. 19 Block insulation for temperatures up to 1900 F. Blocks for insulating refractory brick surfaces are usually laid up with HiTemp Cement and supported in place by an outer wall of metal or brick. Blocks for application over superheated steam surfaces are held in place with wire loops or other supporting means as described for 85% Magnesia Blocks. Fibrous adhesive can be used to adhere blocks to surfaces as an additional securemem but only when surfaces do not exceed 800 F. For higher tempera tures, blocks should be wired to the surface. Consult the Insulation Contract Department or the Plymouth Meeting Office when conventional methods of application cannot be used. Furnished in flat and curved blocks for covering large surfaces. Also furnished as cement to be mixed with water for filling cracks and openings between blocks. Packaging: Hi-Temp blocks are packed in cartons. The same carton packaging data shown under Filter Press 85% Magnesia blocks also apply to Hi-Temp blocks except that Hi-Temp weights are 50% heavier. Density of Hi-Temp is approximately 24 lbs. per cu. ft. / DESCRIPTION TABLE OF RECOMMENDED THICKNESSES Temperature Range-- F. Hi-Temp Inner Layer--In. 85%Mag. Outer Layer--In. Carey Hi-Temp No. 19 Clock is made of diatomaceous earth, asbestos fibre and refractory bonding clay molded into block form for greatest use at high temperatures. FEATURES 1101 to 1200 1001 to 1100 901 to 1000 801 to 900 701 to 800 550 to 700 3-1/2 3 2-1/2 2 1-1/2 1-1/2 1-1/2 2 2 o 2-1/2 2 . High thermal efficiency--K Factor (conductivity) at 600 F. mean tem perature (average between inner and outer surfaces of insulation) is 0.64; at 8000 o.68; at 1000 F., 0.69. . Heat expansion up to 1900 F.--none. Standard Sizes*. Lengths - 18" and 36". Width ' Thickness -- Inches 6*' Curved 9" 12'* Flat 3", 6" Flat 1-1/2, 2, 2-1/2, 3 1-1/2, 2. 2-1/2, 3, 3-1/2, 4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2, 4 < . Incombustible--all mineral. y . Noncorrosive. . High compressive strength--approx imately 95 ibs. per sq. in. . High bending strength--modulus ap proximately 75 lbs. . Small heat shrinkage--0.4% at 1000 F.; 1.00% at 1500F.;2.5% at 1900O F. . High salvage value--broken material can be ground and used as cement. . USES For use in insulating ovens, furnaces, kilns, lehrs, regenerating chambers, breechings and ducts where the outer surface of the refractories does not exceed 1900 F. In general, blocks are used as a first layer, followed by an outer layer of 85% Magnesia in such corebinhtions that the 85% Magnesia will not be exposed to temperatures higher than 600 F. WOOL FELT PIPE COVERING PERFECTO ^industrial (insulation Recommended Thicknesses -- and end joints staggered and brought Temperatures 225 F. to 60 F. -- Normally, 3/4" thickness is satis factory, but for severe humidity conditions together firmly. When insulating piping, operating in the lower range of recom mended temperatures, joints of the inner double 1/2" thickness is recommended. layer should be sealed to prevent the Temperatures from 60 F. and 45 F. Double layer construction is also rec ommended. Also, see Page 12 (Impervo). infiltration of moisture. Covering shall be secured in place by pasting down the side and end laps of the factory applied canvas jacket. If additional securement Sizes: Perfecto is furnished only in semi-cylindrical sections 36" long, for pipe sizes up to and including 36". It is available with bands in thicknesses of 1/2", 3/4", 1", double 1/2", double 3/4". Other thicknesses available on is desired, copper staples shall be in stalled under the canvas lap and over the side joints. Standard metal bands are also used as additional securements. Bands should be placed at end joints and in the middle of each section. special order. Fittings shall be insulated with one or more layers of Hairfelt built up to a thickness equal to the adjacent pipe in t DESCRIPTION APPLICATION Note: To insure maximum efficiency sulation. It is recommended that each layer of Hairfelt be sealed with spiral wrapping of insulating tape. Finally, the Perfecto is a semi-rigid structure made of multiple layers of indented "dry" insulating felt (wool felt) firmly cemented pipes and fittings must be installed to allow a full thickness of insulation to be applied throughout. fitting should receive a smooth coat of Asbestos Cement and a canvas jacket neatly pasted in place. In the lower together. The inner surface is lined with asphalt-saturated organic fell. Carey Perfecto covering is furnished with a white wrapper under the canvas. Single Layer -- Sectional Covering shall be applied to the straight run of pipe with all joints brought together firmly. Cover ing is secured in place by pasting down temperature range we recommend that the outer layer of insulation be stepped back approximately 1-1/2" from the end of the inner layer at fittings, and when insu lating over hangers. This will provide USES the lateral and end laps of the factory the broken joint type construction applied canvas jacket. If additional throughout, which is very important when Perfecto is an efficient economical pipe securement is desired, standard metal insulating against condensation. insulation for temperatures between 60 F. and 225 F., keeping hot water hot and cold water cold, and preventing bands may be installed over end joints and in the middle of each section. All piping exposed to the weather should be waterproofed. We recommend that the sweating of cold water service lines. Fittings in lines covered with single straight pipe be weatherproofed with 45 For service water temperatures between layer (Perfecto W'ooifelt) can usually be lb. Surety Roofing which is an asphalt 45 F. and 60 F., integral jackets with insulated with MW'-SO cement. The saturated and coated jacket. Side and properly sealed joints give adequate fittings shall be roughed in to a thick end laps should be a minimum of 2" service for intermittant operation. For ness equal- to the adjacent insulation and sealed with lap cement. To insure continuous operation a water vapor and allowed to dry. After the cement is best results all side laps should face \ barrier integral jacket should be used. thoroughly dry, fittings should be downward to shed water and the jacket Under such conditions refer to Impervo smoothed off with a second coat of held in place with loops of copper clad and Table of Recommended Thicknesses Asbestos Cement and canvassed. wire on 6" centers. Fittings exposed to on next page. Perfecto is not designed the weather shall be weatherproofed with for dual temperature systems. Double Layer -- Perfecto shall be applied Carey Insulation Seal and reinforced Note -- In cold or chilled water line pip to the straight runs of pipe with lateral with Ciasfab. ing all conditions such as air tempera ture, humidity, type of insulation, or any extreme condition must be considered carefully. If proper precautions are not taken in the choice of insulation and in its installation, sweating and condensa tion can cause extensive damage thruout the building. SPECIFICATIONS Perfecto has a very high insulating value, much better than old-type solid wool felt coverings. K-Factor (conduc tivity) is approximately the same as cork and hair felt .25 to .30 at 50 F. Perfecto is finished with 10.2-yards-perpound cotton cloth jackets. Heavier canvas jackets can be furnished. Per fecto can be finished with roofing jackets, such as the Carey recommended jacket of 45-lb. Surety Roofing. Carey Perfecto is shown installed in Cincinnati, Ohio food plant. Perfecto can be used to insulate service water piping systems down to 45. WOOL FELT PIPE COVERING IMPERVO industrial insulation DESCRIPTION Impervo is composed of multiple layers of insulating felt with water resistant felts on the inner and outer surface of each layer. It is furnished in sections three feet long with canvas jacket, for ' ' iron and copper pipes from 1/4" M", and is regularly made in Double a and Double 3/4" thickness. Other th>^icnesses can be made special to order. Four inch (4") wide collars for sealing end laps, as well as longitudinal flaps on outer water resistant felt will be furnished special on request. USES vo is used primarily for insulating chilled water and ice water pipe lines operating at temperatures between 40 F. and 60 F. It is specially designed to keep water cold and prevent condensa tion causing damage from dripping. Recommended for cold service water piping under particularly high humidity conditions such as in laundries, kitchens, bakeries, textile and paper mills. SPECIFICATIONS Impervo has a high insulation value, approximately the same as cork and hair felt. Its K Factor (conductivity) is in the range of .25 to .30 at 50 F. Service Range: Impervo used to proper ' nesses is recommended for cold 'e water service. The table shows ti. oper thickness to prevent sweating for various differences of temperatures between the surrounding air and water in the pipe and for various degrees of humidity: Humidity Temperature Difference of. Water To Air S0 F. 60 F. 700 F. Max. In. Max. In. Max. In. Up to 70% 70-80% 80-85% 1" M4" 2" 1" 2" 2-H" Mi" 2" 3" In cases where water temperatures are 50 F. and beiow and relative humidity exceeds 75%, special precautions must be taken to assure proper vapor sealing of all joints and surfaces to prevent the infiltration of moisture vapor through the insulation. This should include the following: 1. Use of longitudinal flap and 4" collars at all end joints, properly sealed with Carey Insulation Seal No. 830. 2- All fittings to be made from standard hairfelt securely sealed to adjacent layers of covering with insulating tape. 3. Where severe conditions exist, sur face of both pipe insulation and fittings must be brush coated with Carey Insulation Seal No. 830 to assure a proper moisture vapor seal. Impervo is not recommended for the in sulation of most dual temperature systems. Consult General Office for recommendation of type of Impervo in sulation for dual temperature systems, giving maximum percent of humidity and maximum air temperature. APPLICATION All piping and fittings shall be insulated as follows: Chilled rater Piping Systems: Pipe In sulation - Apply two (2) layers of Carey Impervo. Pipe Covering of thickness in agreement with preceding table, with all butt joints and lateral seams of the second layer staggered with reference to joints and seams of the first layer. Point all joints of inner and outer layers with Carey Insulation Seal No. 830. All covering must run continuous in full thickness through sleeves and be properly tied in with fittings and vapor sealed. Covering may be secured in place by peeling back canvas and longitudinal flap (when ordered) and installing 3/4" x 3/4" or larger copper staples over longitudinal seams on 6" centers. Width of staple must be sufficient to extend over joint. After insulation is secured in place oement down longitudinal flap and collars with Carey Insulation Seal No. 830. At fittings and valves, step back the outer layer of covering at least 2". making sure that all seams are light. Support all insulated lines by Clevis hangers placed on outside of insulation, using a heavy gauge sheet metal saddle through the hanger. Spacing of hangers and size and length of saddles must provide sufficient - load distribution to prevent compression of insulation. Saddles should be formed to exact out side diameter of covering and should extend half way around covering. Where other types of bangers are used a perfect seel must be provided, and the insulation carried up the hanger rod for at least 6". Fittings: insulate with two (2) layers of Hairfelt, each layer lied on with spiral wrapping of 4-ply hemp twine. Apply the first layer of Hairfelt tight against the butt ends of the inner layer of covering and approximately flush with the outer surface of the inner layer. Apply the second layer of hairfelt tight against the butt ends of the stepped back outer layer of covering and ap proximately flush with outer surface of covering. Seal each layer of Hairfelt with a spiral wrapping of insulating tape pulled tight, and lapped on itself to give double thickness. Tape should be extended at least 2" over the ad jacent pipe insulation. Seal each layer of insulating tape with a heavy brush coat of Insulation Seal. Where pipes are exposed, fittings may be finished over insulating tape with a smooth coat of Asbestos Cement, (omitting Insulation Seal) applying a canvas jacket over the Asbestos Cement with a waterproof adhesive. Outside piping, fittings, hangers and vessels may be weather proofed with Insulation Seal No. 830 reinforced with Glasfab or equal. Finish: Thoroughly seal all insulation surfaces with a heavy brush coat of Insulation Seal. Cold City and Well Water: Apply in sulation same as above except the second layer of hairfelt on fittings and the finish vapor barrier coating over the insulation may be omitted. Recommendation for conditions other than described above can be obtained from the Technical Services Department of The Philip Carey Manufacturing Company. Humidity varies greatly over the United States. At times conditions are unusual and excessive. Data showing these extremes of temperatures and humidity may be obtained from your local Weather Bureau. WOOL FELT PIPE COVERING PROTECTO industrial 'insulation canvas jackets can be furnished. Pro tecto can be finished with roofing jackets, such as the Carey recommended jacket of 45-lb. Surety Roofing. Recommended Thicknesses -- Single layer (1-1/4" thickness) is usually satisfactory for latitudes south of Washington, D.C., Cincinnati and St. Louis. Single layer 2" total thickness is recommended for northern latitudes. Effective Protection: No insulation alone can prevent freezing if the water stands still long enough. Some water must be allowed to run during weekend or idle periods. PROTECTION PERIOD AGAINST FREEZING AIR-10 BELOW ZERO F. WATER-520 F. Protect reduces the danger of freezing of exposed piping. DESCRIPTION Protecto is a semi-rigid structure made of two inner layers of cattle hair felt (each layer about 1/4" thick) and an outer layer of insulating felt (wool felt) firmly cemented together. The inner * surface is lined with asphalt-saturated organic felt. USES Hours offProtection Pipe Size Before Freezing Allowing 1/8" thickness of ice to form W Thk. 2" Thk. J-J4" Thk. Protecto Protecto Protecto 2" Thk. Protecto 1" 2" 3" 4" 6" 8" 10" 12" 1.02 2.59 4.23 5.94 9.67 13.22 17.16 20.95 1.54 4.2 7.15 10.2 17.4 24.3 31.7 38.7 4.94 7.59 9.70 11.65 15.70 19.47 23.49 27.38 7.92 12.3 16.40 20.09 28.1 35.65 43.45 50.75 Flow Seeded To Prevent Free zing-- lbs of water 'tin. ft. of pipe 'hr (1 pint 1 lb) 7-W" Thk. Protecto 2" Thk. Protecto .37 .56 .75 .92 1.33 1.64 1.98 2.33 .25 .35 .45 .54 .72 .89 1.07 1.26 Protecto is used only to protect water, gas, oil and other pipes from freezing temperatures. It should never be used on ice water pipes to prevent sweating. SPECIFICATIONS K-Factor (conductivity) is approximately .25. Protecto is finished with 10.2-yards-perpound cotton cloth jackets. Heavier APPLICATION Protecto sectional covering shall be carefully fitted to the pipe with lateral and butt joints tight. The sections are secured in place by neatly pasting the side and end laps of canvas furnished on the covering. Protecto covering may be additionally secured with standard metal bands placed over end joints and in the centers of each section. Cover the fittings with Hairfelt built up to equal thickness of the adjacent covering and secure in place with a spiral wrapping of jute twine. Fittings may be finished with insulating tape or asbestos cement and a canvas jacket pasted in place. It is recommended that the insulation be painted with one coat of size and two coats of lead and oil. / \r V v SUPERBO PIPE COVERING industrial rinsulation Flair-door staples or other devices which puncture the vapor barrier must not be used to hold down tbe flap. Standard bands should be used to hold down tbe flap until tbe adhesive sets after which they may be left in place or removed for subsequent painting or canvassing, joint collars are to be sealed down with vapor barrier adhesive. Ends of the pipe insulation shonld be sealed off with a cot back type asphalt mastic, such as Insulation Seal 830, at all flanges, valves and fittings and at intervals of 21 feet on continuous runs of pipe. These moisture seals retard the spread of moisture should barrier puncture or line failure occur. Carey Superbo is available with either a white or a black vapor barrier jacket con sisting of aluminum foil laminated between two layers of creped Kraft. DESCRIPTION Carey Superbo is a rigid pipe insola tion made of moltiple layers of "dry" insolating felt (wool felt) firmly cement ed together. The inner surface is lined with asphalt saturated organic felt. A factory applied white vapor barrier jacket is furnished consisting of alu minum foil laminated between two layers of special creped Kraft paper, bonded with asphalt. This same vapor barrier jacket is also available with a black outer surface. Superbo is furnished with 4" wide collars of the ttoe vapor barrier material as the jacket. APPLICATION Superbo should be applied over a clean dry surface (wipe off any condensed moisture) with the pipe at ambient tem perature. Adjoining sections should be firmly butted, and if multiple layer construction, all joints are to be stag gered. Tbe longitudinal flap of the vapor barrier and the collars should be sealed down with a suitable rubber base vapor seal adhesive. Vspor seal adhesives should he quick tacking. Where the white side of the barrier is exposed a white adhesive should be used. In erecting the pipe, tbe use of adjust able clevis type hangers with the insu lation passing through the hangers is a preferable mounting, particularly in severe service conditions. The use of saddles, consisting of semi-cylinders of 16-gauge galvanized of a length equal to 4 times the diameter of the pipe insulation is indicated in all cases. In the case of large diameter pipe, where high concentrated loads axe expected at the points of support, the use of a abort length of rigid type insulation on the lower half of the pipe through the hanger loop is recommended to prevent compression of the insulation. If direct contact clamp hangers are used, the hanger is to be insulated independently of the straight run cover ing in the same manner as any valve, flange or other type of fitting by the following method. 1. Hanger rod should be insulated to a minimum height of four times, the pipe insulatiou thickness (or prefer ably 12*' where possible) with inso lation similar to that covering tbe USES Carey Superbo is a doal temperature pipe insulation for chilled water piping or piping operating at alternating high and low temperature with a service range of from 35 F. (lower limit) on the cooling cycle to 200 F. (maximum) on the heating cycle. The integral vapor barrier jacket properly applied and sealed will protect chilled water lines from condensation or sweating. Thickness requirements vary with the pipe size and conditions oftemperature and humidity. Where recommended thickness exceeds 1-1/2** and the pipe size is 6** and over, double thick Superbo construction and broken joist application is required. The longitudinal flap of the vapor barrier should he sealed down with a rubber base vapor seal adhesive. Vapor seal adhesive should be quick tacking. Banda may be used to hold down tbe flap until adhesive dries. Corey Industrial Insulation Superbo Pipe Covering pipe, having an I. D. approaching as nearly as possible the diameter of the hanger rod and one-half the is* 'alation thickness used, on the pipe oper. 2. l he hanger rod insolation, the inso lation collar over the clamp, and the area extending 2*' beyond the collar on each side should be sealed with 2 coats of a cot back type asphalt mastic (Insolation Seal No. 830) re inforced with saturated glass fabric between coats. 3. The area boosing the clamp hanger between the ends of pipe insolation should be closed by a collar of in solation materialsimilar to that osed on the pipe, with an 1. 0. equal to the 0. D. of the pipe insolation and half the thickness, and shall extend two inches over the ends of the pipe insolation on each side, and be sealed as described above. e ends of tbe pipe insolation eniosed by the joint collar should be moisture sealed with a cot back type asphalt mastic (Insolation Seal 830), 5. The voids in the area boosing the clamp hangershoold be firmlypacked with hair felt. 6. The pipe insolation should have Starrier laps firmly sealed in the ;me manner as on the straight rons pipe. FINISHES As an indoor strface finish, the barrier surface may he considered adequate with or without bands. The barrier may not he painted directly. Paint tbe barrier with asphalt base alominom paint or other asphalt compatible finish. Follow with con ventional lead and oil paint. Pigment ed PVA emulsions in code colors also serve as highly desirable final finishes. Insulated piping exposed to the weather should he finished with 45# roofing felt lapped at least 3** at all joints and sealed with lap cement. Edge of the horizontal lap should end slightly be low the level of tbe horizontal axis of the pipe in order to shed water. Final securemeas should be made with soft aluminum bands on 12*' centers or 16gauge galvanized or copper wire on 8" centers. Wire should not be drawn so tightly as to pierce the jacket. SPECIFICATIONS Sizes Available . .......................... 1/2** through 36** Iron Pipe Size 1/2** through (bl/8" Copper Tubing Semi-cylindrical sections -36** in length-binged Thickness.......................................... 1** and 1-1/2** thickness Jackets............................................. White Vapor Barrier Black Vapor Barrier Collars 4** wide furnished with each section K Factor.................................................. 29 at 50 F. Vapor Transmission.................... Vapor barrier jacket has a Perm, rating after flexing of O.Oz Max. at 95% RH at 100<> F. Jacket has a 15% stretch characteristic in both directions. TABLE OF RECOMMENDED THICKNESSES FOR AMBIENT AIR CONDITIONS OF 90 F. & 90% R.H. (Based on "K" of .28 9 40 F. Mean) IRON PIPE SIZES COPPER TUBING Other fittings such as elbows, teea, flanges and valves shall also be insolated independent of the straight ran covering. After the ends of the adjacent covering has been sealed with mastic (Insolation Seal No. 830), the body of the valve, tee, elbow or flange should b? -atly covered with hair felt securely li r place, of a thickness eqoivalent to me adjacent insolation. The fitting insolation is then shaped by enclosing the hair felt neatly taped with pressure sensitive black vapor barrier tape. If moltiple layer broken joint construc tion is employed, the ends of the inaulation sbouldbe staggered at the fitting and separate layers *f hair felt carried through the fitting irsolation with tape between each layer. The taping should be extended a foil two inches on each side, on each layer, of tbe adjacent covering. A final outer vapor seal should be accomplished by two coats of vapor seal mastic (Insolation Seal No. 830) reinforced with saturated glass fabric between layers and carried oi* two inches on each side on tbe adjacent covering. If color is a factor, a whire form of tape is available, and tb* final finish coat can be made with us of white robber base vapor seal ive reinforced with an untreated g fabric. AQ valves, bandies, stems or other protuberances on fittings shoold be erected in an inverted position. Inso lation should be carried oot contin uously through all walls, partitions or other interfering structmes. Temperature 350 F 40 F Temperature 35 F 40 F Size Recommended Recommended Thickness Thickness Size Recommended Recommended Thickness Thickness 1/2" 3/4" r* 1-1/4" 1-1/2" 2'* 2-1/2" 3*' 4" 5** 6** r* 8'* 9** 10" 11" 12" 14** 16" 18** 20" 24" 30" 36** 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2'* 2" 2" 2-1/2** 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2** 2-1/2" 3" 3" 3" 3" 3" 3" 1-1/2" 1-1/2" 1-1/2** 1-1/2*' 1-1/2" 1-1/2" 2" 2** 2" 2" 2" 2" 2" 2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 1/2" 5/8" 3/4" 7/8" 1-1/8" 1-3/8** 1-5/8" 2-1/8" 2-5/8" 3-1/8" 3-5/8" 4-1/8" 5-1/8" 6-1/8" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2*' 2" 2" 2" 2" 2" 2" 2-1/2" 2-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2" 2" 2" 2" 2** Insulatioo thickness s h o n 1 d in all cases he chosen to meet the severest possible conditions of temperature and relative humidity anticipated on the lower end of the cycle when used in dual range or chilled water service. CAREYCEL PIPE AND BLOCK INSULATION Fmdustrial ^insulation SPECIFICATIONS THERMAL CONDUCTIVITY large amounts of water vapor, the thick ness of Careycel should be selecte from the table, choosing the worst con ditions of relative humiditv and tempera ture differential, and a vapor barrier mus be provided to seal outer surface. A! thicknesses specified incorporate . safety factor of 10% to 20% over th indicated thickness actually required tc prevent condensation of moisture on ttu insuiation surface. SIZES: Pipe Coverings: Careycel pipe covering! are furnished in 3-foot split cyiindrica sections, in thicknesses of 1", 1-1/2'' and 2", for iron pipe or copper tubing Cotton jackets are attached. Blocks and Sheets: Flat blocks are fur Careycel Pipe Covering and Block t Insuiation has 12 or more layers of pre MEAN TEMPERATURE F. nished in standard 6" x 36" size Standard sheet or board size is 36" x 36' formed asbestos paper per inch of thick Careycel Board is especially recommended but special sizes can be furnished up t< ness -- each layer being an effective for a neat and workmanlike appearance 36" x 96". Thicknesses: 1/4" to 3' heat barrier. This special construction gives Careycel a much lower K Factor on exposed duct work. One-inch thick Careycel is recommended for all appli in 1/8" increments. than conventional corrugated asbestos cations except air-conditioning ducts Packaging: Careycel pipe covering ii insulation, such as Aircell and Excel. in high-humidity surroundings. For a duct packed in dirtproof, moistureproof carton? DESCRIPTION passing through a laundry room, kitchen, to minimize waste and breakage. Block? or where any heated equipment emits and sheets are also specially packed Careycel is designed for temperatures up to 300 F. and is an improved type of asbestos heat insulation for pipes, heaters, and hot or cold air-conditioning ducts. Careycel provides greater in sulating efficiency for a given thickness, a feature which is the result of a patented processing method. Each sheet of asbestos paper is fabri cated with innumerable minute indenta tions that are deep and firm. In forming Careycel, these sheets are laminated to provide any desired thickness. Careycel has 12 or more asbestos layers per inch of thickness, each layer being an ef fective heat barrier. Relative Humidity 60% 70% 80% 85% 90% Careycel 'Diickness Required to Prevent Sweating Temp. Differential -Room Air To Duct Air 20 F 25 F 30 F 35 F 40 F 45 F 1/4" 1/2" 3/4" 1-1/4" 2" 1/4" 1/2" 1" 1-1/2" 2-1/2" 1/2" 3/4" 1-1/4" 1-3/4" 3" 1/2" 3/4" 1-1/2" 2" 3-1/2" 3/4" 3/4" 1-3/4" 2-1/4" 4" 3/4" 1" 1-3/4" 2-1/2" 4-1/2" 50 F 3/4" 1" 2" 2-1/2" 5" FEATURES High insulating efficiency^xtremely low K Factor. . Minimum shrinkage--only .05% (about one-tenth of conventional air-cell typ). . Smooth--no unsightly ridges to catch and hold dust and dirt. . . Firm--easy to handle and install, with stands more abuse. . Noncombustible. . Light weight. USES For temperatures up to 300 F., Careycel is one of the most efficient, easily installed, permanent and low cost in sulations for piping (hot water, steam heating system, process), duct systems, ovens and kilns, appliances, and hot equipment such as boilers, heaters, and tanks. One-inch thick Careycel covering gives effective insulation for most of these applications. Careycel Pipe insulation installed on steam piping in boiler room of Metro-ColdwynMayer movie studios. Culver City, California. Corey Industrial Insulation PLICATION Pip.j: Paste down cloth jacket laps and apply metal hands on 18" centers. In sulate fittings and valves with Carey No. 303 Asbestos Cement, bringing the cement surfaces flush with adjacent pipe covering, and finish with pasted cloth jackets. Paint finish can be one coat of cold-water paint with two coats of lead and oil. Use varnish size in the first coat of lead and oil. Duct Systems: For ducts up to 18" wide, wire boards in place, pulling wires tight and embedding them in the boards. Space wires on approximately nine-inch centers. For ducts over 18" wide, apply boards with sheet metal screws and tin caps, forcing the caps approximately 1/4*' below the surface of the board. Space screws so that each one supports app/ lately two square feet of board. Fill all cracks and joints with cement composed of a mixture of 1/3 Portland Cement and 2/3 Carey No. 303 Asbestos Cement. Over all edges paste down eight-ounce canvas strips six-inches wide. Where insulation is applied in exposed places eliminate the canvas strips and finish the entire insulated surface with '-ounce canvas pasted on. Paint s with two coats of lead and oil p with varnish size in the first coat. Hot Equipment: Wire Careycel blocks on approximately 12-inch centers. Over the blocks apply one-inch hexagon wire mesh stretched tight. Follow with a 1/2-inch coat of Carey No. 303 Asbestos Cement (or Carey No. 100 Cement for a very hard fir' ` ), troweled smooth. Finish with ei\^ ounce canvas jacket pasted on, and paint as specified for Careycel pipe covering. Careycel Pipe and Block AIRCELL PIPE COVERING AND BLOCK industrial insulation Aircell should not be used for outdoor or underground line because it will not support roofing jackets or withstand water. Sizes: Semi-cylindrical pipe covering is furnished in sections 36" long for pipe sizes up to 36'*. Thicknesses: 12", 3/4", 1". Aircell can be used at temperatures up to 300 F. DESCRIPTION SPECIFICATIONS Aircell pipe coverings are normally fur nished with white asbestos paper jackets or cotton jackets (10.2 yards per pound) and metal bands. Heavier canvas jackets can be supplied. Aircell coverings are not furnished with factory-applied roofing jackets. THERMAL CONDUCTIVITY Aircell blocks are furnished in standard 6" by 36" size. Standard sheet size is 36" x 36", but special sizes can be furnished up to 36" x 96". Thicknesses: 1/4" to 3" in 1/4" increments. APPLICATION Pipe Covering-Cold water flour paste is used to secure canvas laps along lateral joints and at joints where sections abut. Metal bands are applied approx imately 18" apart, usually over butt joints and in the center of sections. Fittings should be insulated with as bestos cement. Aircell is a lightweight asbestos paper structure comprising alternate layers of corrugated and flat asbestos paper firmly cemented together. Corrugations are 1/4'* deep, four plies per inch of thick ness. Aircell is the most economical in combustible asbestos insulation. USES Blocks--Blocks are usually held in place with 14-gauge or 16-gauge wire loops spaced approximately 12" apart. Joints are pointed up with asbestos cement. Carey Fibrous Adhesive can be used to adhere blocks to surfaces as an additional securement. Hexagonal wire mesh, 1-1/2-inch, is stretched tight over the blocks as a reinforcement when an asbestos cement finish coat is required. Aircell is designed primarily for indoor heating systems and process piping and equipment where steam does not exceed approximately 70 psi or 300 F. Aircell should be used only where high effici ency, strength and durability are not as important as initial low cost application. MEAN TEMPERATURE F. FOR* NO. 700? - REV. W - i K-CL 17 i u.r DEFENDEX PIPE AND BOARD INSULATION SPECIFICATIONS industrial Einsulation --r*Yr-- - -- THERMAL CONDUCTIVITY Sizes: Defendex is furnished in seraicylindrical pipe covering sections 36" long for pipe sizes up to 36**. Pipe cover ings are regularly finished with 3.8 ounce cotton duck jackets and bands. Heavier cotton duct or roofing jackets can be furnished. Defendex is also available in flat blocks and sheets. Blocks: 6" x 36". Sheets: 36" x 36". Special block and sheet sizes made to order. Standard thickness is 1*', however, thicknesses up to 2-1/2" can be provided. 0.4!1III I 100 200 300 ' 400 f MEAN TEMPERATURE F. Defendex pipe and board insulation is designed for temperatures up to 550 F. DESCRIPTION Defendex is a semi-rigid structure com prising approximately 20 to 22 alternating layers of flat and processed asbestos paper per inch of thickness. The pro cessed asbestos paper contains innumer able, very fine indentations, which give proper spacing between succeeding lay ers. Defendex gives high efficiency at medium price. Comparative Efficiencies Table Of Comparative Efficiencies Of 1-inch Thick Pipe Coverings On 3-inch Pipe Steam Pressure and Temperature 5lh 226.8 F SO lb. ' 297.7 F. 100 lb. 339.2 F. 200 lb. 387.8 F. Defendex 85% Magnesia 80.2% 81.6% 82.3% 83.9% 83.2% 84.9% 84.2% 86.0% USES \ Defendex is an economical, high effici ency insulation designed to insulate boilers, pipes, ovens and other apparatus operating at temperatures not exceeding 550 F. It is also furnished in large curved shapes for metal jacketed boilers. GMBfTOt STAPLE UP Defendex is especially adapted for in sulating steam traced pipes. It can be manufactured in any special shape to cover two or more pipes. These sections can be cut as specified, at the top, bot tom or on the side for easy installation. TUGS UNE 20-22 ALTERNATING LAYERS PER INCH H&0 APPLIED WEATHERPROOFING STAPLE GAUNT OR STAPLE LAP TUGS UXE Fireclad or other types of weatherproof jackets can be applied for protection against weather. TEAR DROP SECTIONS'FOR TRACED LINES ASBESTOS SPONGE PIPE AND BLOCK INSULATION findustrial iinsolotion OPTIMUM ECONOMICAL THICKNESSES FOR AVERAGE CONDITIONS Pipe Sizes Temperature Range 0 F Vj to 1-Vj 2 to 3-`2 4 to 6 7 to 10 12 L overm 550 to 700 450 to 549 350 to 449 250 to 349 150 to 249 2" 2" 1-54" 1" 1" 2-5:" 2" 2" 1-!*" 1" 3" 2-5." 2" 1-5-" 1" 3" z 2" l-vf 3-V 3" 2-1-" ** I-1:" This column represents recommended thicknesses also for tanks and equipment. Asbestos Sponge insulation, for tern* peratures up to 700 F. DESCRIPTION Asbestos Sponge is a firm resilient structure made from a series of laminated asbestos felts, averaging 30 to 35 layers per inch of thickness. Closely held air films, both within and at the surface of the layers, give Asbestos Sponge its excellent insulating efficiency. is applied in the field we recommend that the jacket be applied with a min imum 2'* lap at lateral and butt seams and sealed with lap cement. Finally, No. 16 ga. wire loops of copper clad or galvanized wire shall be tied over the roofing jacket on 4 centers. Fittings should be insulated withMW-One Cement or asbestos cement, flush with adjacent covering and finished with pasted canvas jackets. For outdoor piping, finish with an additional 1. 4" wet coat of Thermotex 4<B" extending two inches over the adjacent roofing \ 00 200 300 400 jackets. Wet brush to a smooth finish. Asbestos Sponge construction is sub* MEAN TEMPERATURE F. Flanged fittings and pipe fittings larger stantial, yet flexible enough so that it will not become damaged during shipment APPLICATION than four inches should be insulated with a combination of 85% Magnesia or installation. It can be removed from blocks and cement. pipe or equipment and reapplied without Pipe Covering: Sponge felt covering is loss of material. easily applied by placing the sectional Blocks: Usually held in place with 14- USES covering over pipe, making sure that the gauge or 16-gauge wire loops spaced lateral and end joints are tight and approximately 12" apart. Joints are securing the canvas laps with cold pointed up with asbestos cement. Carey For surfaces with temperatures up to700 water paste. If additional assurance is Fibrous Adhesive is sometimes used to V F. Specifically recommended for use on desired metal bands may be applied at vibrating lines and underground steam butt joints and in the center of sections. adhere blocks to surfaces as an extra securement. One-inch hexagonal wire distribution lines because its structure Covering exposed to the weather should mesh is stretched tight over the blo.cks is tough. Cylindrical pipe covering sec be protected with a roofing jacket, as a reinforcement when .'n asbestos tions can be furnished for large pipe usually 45 lb. Surety. If roofing jacket cement finishing coat is required. sizes. Blocks and sheets are designed for use on stills, tanks, boilers and other large surfaces where the insulation must with stand extremely rough service. SPECIFICATIONS Pipe covering is regularly furnished with 3.5-ounce canvas to meet Federal Speci fication HH-l-561c, when so indicated on order. Heavier jackets can be fur nished, as can roofing jackets for out side service. SIZES: Blocks and Sheets-Standard length: 36". Standard thicknesses: 1", 1-1/4", 1-54", 1-3/4", 2", 2-1/2", 3". Standard widths: 6", 9", 12", 18", 24", 36". Pipe Covering--Furnished in split cylindrical sections 36" long for pipe sizes up to 36''. Standard thicknesses: from 1" to 3-54". Tough, rugged Carey Asbestos Sponge insulates and protects piping in Canada Sugar Refining Company plant. ' N- * A' | industrial FLEXIBLE TUBING INSULATION fejnsulation t CAREY FLEXIBLE TUBING INSULA TION is e tough, flexible, polymeric material constructed of millions of uni form closed cells. It can be used on any line operating between 20 below 0F. and 200F. DESCRIPTION Ci / Flexible Tubing Insulation is maae of Hycar man-made rubber, an ex tremely oil-resistant material. It was developed to overcome the loss in effi ciency which can occur with open cell (sponge rubber) tubing, i.e., when used as insulation on cold water lines, hot, humid weather may cause open cell tubing to absorb water vapor which condenses and destroys insulation efficiency. Carey p,-*xible Tubing Insulation prevents this >Ie. Its millions of tiny cells are non connecting; each one sealed off ft* _ its neighbors. It is impervious to water vapor and will not lose its effi ciency due to moisture absorption. A highly efficient pipe insulation, it can be applied with remarkable speed and ease to copper tubing and iron pipe. It is so flexible that it can be bent, twisted and formed and yet so resilient that it so .s back to its original shape when PV a place. It is made in continuous lengths, in many wall thicknesses, and will withstand temperatures from minus 20F. to 200F. FEATURES The K factor of Carey Flexible Tubing Insulation is .26. 1/2*' wall tubing is recommended for severe conditions while thinner wails may be used under less severe conditions or where economy is of prime importance. It resists deterioration and moisture absorption, so efficiency remains high in service. The uniform closed cell structure seals out air and moisture. The result is a water vapor transmission rating of less than 0.1 PERM. Because of its excellent temperature resistance, Carey Flexible 'ng Insulation can be used to insulate carrying hot as well as cold water. It -mS excellent weather-aging properties. Samples have been exposed in the Atlas Weatherometer for 100 hours (equal to 6 months to a year outdoor aging) with only barely visible cracking. The material is also resistant to the deteriorating action of Ozone. Carey Flexible Tubing Insulation is flame-resistant and will not support com bustion. A standard test is to hold a sample over a 2** Bunsen Burner flame for 30 seconds. After removal from the flame the time of burning is noted -- less than i/2 minute by this test. completely assembled, the tubing is split longitudinally, cut into proper lengths and snapped onto the lines. Cut seams are joined together with cement. In all cases, these same adhesives can be used to seal end joints and no other sundry material is required. Carey Flexible Tubing Insulation is a strong, tough material. The tensile strength varies, depending on the density and cross section. Pieces of 1/2" cord gave tensiles of 150 PSI and elongation of 200% to 225% at break. USES Carey Flexible Tubing Insulation is recommended for insulation of dual tem perature lines carrying hot or chilled water from a central system to air con ditioning units in hotels* apartments and office buildings. Many of these lines are formed copper tubing and are difficult to insulate, even with semi-rigid materials. When Carey Flexible Tubing Insulation is used, job experience has shown laborsavings of 50% and higher in these applications. Carey Flexible Tubing Insulation can be used to advantage on any line operating between 20 below 0F. and 200F. where flexibility, high insulating value, vapor resistance and ease of application are important. APPLICATION When applied to copper tubing before sweat fittings connections are made, the tubing is pushed back along the pipe and held back with clamps until the joint is soldered. The self-extinguishing proper ties of Carey Flexible Tubing Insulation made this time-saving application method feasible. Once the fittings have cooled, the clamps may be released and the tub ing slipped back to cover the fittings. SPECIFICATIONS Density.....................6-12/lbs./cu. ft. K Factor..................0.26 Water Absorption. . 10% max. Temperature Range -2(P F. to 200F. Flame Resistance. Will not support combustion Weather Agin$ . . . Excellent Tensile Strength. . . 150 psi Fungus & Vermin Resistance .... Excellent 2ASTM D1056-53 Method Thermo! Conductivity at Various Temperatures There are two practical methods of ap plying Carey Flexible Tubing Insulation. The faster and easier way is to slip the insulation on pipes or tubing as they are being installed. A factory-applied coat ing of talc on the inner surface minimizes resistance, and speeds slip-on applica tion. In cases where the piping has been Application in close quarters is easily done by slipping the insulation on the tubing as it is being installed. A factory applied coating of talc on the inner surface mini mizes resistance. / r v ( K. THERMOGLAS PIPE COVERING (industrial (insulation DESCRIPTION Thermoglas pipe covering is used on pipes having temperatures up to 350 F. It simply "snaps in place". Unusual Permanence-will not sag, rot, mold, or otherwise decompose. Resists attack of most acids and alkalies, and is not corrosive to metals. Will not chip, flake, dent*, break or crumble, and is un affected by water and insects. Thermoglas is also an excellent cold anc dual-temperature insulation when used with a vapor barrier jacket. Available types of vapor barrier jacketing and weatherproof jacketing: Thermoglas is exceptionally lightweight insulation composed of long, fine, blown glass fibers bonded with thermal-setting phenolic resin. It is a strong, semi-rigid and resilient insulation with no coarse fibers to irritate hands or skin. FEATURES Lightweight--weighs one-tenth to onefourth as much as other insulations...less weight on pipe supports. Easy Application--practically a one-hand operation. Cuts application costs. Very Low Moisture Vapor Pickup Excellent Workability--cuts easily to fit valves and fittings. USES Thermoglas pipe covering is used for pipe temperatures up to 35(j F. It is recom mended for hot water and low-temperature steam piping in industrial plants, com mercial buildings and institutions. Ther moglas can be used as an outside layer over a high-temperature insulation. Angier ior Dual Temperature Black Angier for Dual Temperature - White Foil Faced Flame Proof Kraft Jacket Available Types of Weatherproof Jacket ing: 35-lb. Roofing Jacket 45-lb. Roofing Jacket 55-lb. Roofing Jacket Available with Standard Weight 4-oz., 6oz., and 8-oz. canvas jackets. SPECIFICATIONS TABLE OF RECOMMENDED THICKNESSES* FOR INDUSTRIAL, COMMERCIAL, INSTITUTIONAL PIPING Pipe Surface Temp. F. Temp. Differ ence, F. Pipe Site Pipe Insulation Surface Temperature Under 100 F 80 F Ambient Still Air 150 200 250 300 350 70 120 170 220 270 Nom. Heat Nom. Heat Nom. Heat Nom. Heat Nom. Heat Thick. Loss %Eff. Thick. Loss %Eff. Thick. Loss %Eff. Thick. Loss %Eff. Thick. Loss %Eff. % K 9 78.4 K 16 80.4 54 20 84.5 I 24 87.5 IK 28 89.2 1 K 12 77.2 54 17 83.3 1 21 86.8 1 28 87.4 IK 30 90.5 iy* K 13 79.8 54 18 85.5 1 27 86.4 IK 26 90.9 IK 33 91.3 1'/: K 16 78.1 54 22 84.8 1 27 87.9 IK 29 90.9 IK 34 92.2 2 K 17 80.6 54 25 85.5 1 32 88.5 IK 33 91.6 IK 43 92.0 2K Vt 20 80.8 54 29 85.9 1 37 . 88.8 IK 42 91.0 2 45 93.0 3 K 27 78.7 54 36 85.3 1 43 88.9 IK 44 92.2 2 48 93.7 3K Vt 30 79.1 54 40 85.8 1 41 90.8 IK 55 91.3 2 58 93.3 4 K 32 80.2 54 44 85.8 1 52 89.4 IK 54 92.5 2 57 94.1 4k K 26 85.3 54 47 86.4 1 49 91.0 IK 66 91.7 2 68 93.6 5 K 39 80.0 54 53 86.3 IK 46 92.4 IK 64 92.7 2 68 94.2 6 A 48 78.9 54 62 86.1 IK 56 92.1 IK */S 92.6 2. 77 94.4 7 54 56 81.0 1 58 88.6 IK 61 92.5 IK 82 93.0 2 87 94.5 8 54 63 78.6 1 62 89.2 IK 68 92.5 IK 91 93.1 2 95 94.6 9 54 64 80.5 1 69 89.1 IK 75 92.6 2 76 94.8 2 100 94.9 10 54 80 77.9 1 80 88.7 IK 80 92.9 2 87 94.6 2 110 94.9 11 1 44 85.0 1 80 89.7 IK 86 92.9 2 94 94.6 2 120 94.9 12 1 48 88.7 1 86 89.6 IK 94 92.9 2 100 94.6 3 95 96.3 14 1 57 87.6 1 105 88.5 IK no 92.3 2 115 94.5 3 105 96.2 15 1 61 87.6 1 110 88.5 IK 115 92.4 2 120 94.5 3 110 96.2 16 1 65 87.6 1 115 88.5 IK 125 92.4 2 130 94.5 3 120 96.2 17 1 69 87.6 1 125 88.4 IK 130 92.4 2 135 94.5 3 125 96.2 18 1 72 87.6 1 130 88.4 IK 135 92.4 2 145 94.5 3 130 96.3 19 1 76 87.6 1 140 88.4 IK 145 92.4 2 150 94.5 3 140 96.3 20 1 80 87.6 1 145 88.4 IK 150 92.4 2 160 94.5 3 145 96.3 21 1 84 87.6 1 150 88.4 IK 160 92.4 2 165 94.5 3 150 96.? 22 1 88 87.6 1 160 88.4 IK 165 92.4 2 175 94.5 3 155 96.3 23 1 91 87.6 1 165 88.4 IK 170 92.4 2 180 94.5 3 165 96.3 24 1 95 87.6 1 175 88.4 IK 180 92.4 2 185 94.5 3 170 96.3 * Where maximum efficiency is of primary importance Carey Industrial Insulation Thermoglas Pipe Covering TABLE OF RECOMMENDED THICKNESSES- FOR HOT WATER AND LOW-PRESSURE STEAM Pipe Insulation Surface Temperature Under 120 F 80 F Ambient Still .Air Pipe Surface Temp--F Pipe Si2e--In. v< 1 1-4 1-54 2 2-4 3 3-4 ru 5 6 ( 8 9 10 11 12 150F A on. Thick. Inches %Eff. X 78.2 X 77.0 79.6 X 77.7 X 80.2 4 80.5 Vi 79.2 Vi 79.2 Vi 80.0 Vi 85.4 Vi 80.2 X 78.7 X 78.6 Vi 78.3 4 80.4 % 77.9 1 88.8 1 88.8 200F A'om. Truck. /nches % Eff. X 80.4 V 79.2 X 81.8 Vi 79.9 Vi 81.8 Vi 82.2 Vi 80.8 Vi 80.8 Vi 81.5 Vi 86.5 Vi 81.8 Vi 80.4 .'2 80.5 4 80.0 X 81.7 X 79.6 89.7 89.6 250F A'om. Thick. Inches % Eff. X 81.9 Vi 80.6 X 82.9 X 81.0 X 83.2 X 83.3 Vi 82.0 X. 82.0 Vi 82.6 X 87.4 X 83.0 X 81.7 X 81.6 89.8 89.9 1 89.5 90.2 90.2 300F A'om. Thick. Inches 55 Eff. X 82.9 X 81.4 X 83.9 x 86.6 % 87.2 X 87.4 % 87.0 3/ /4 87.6 % 87.5 X 88.2 %/ 4 88.0 3/ /4 87.8 1 90.0 1 90.6 90.5 90.1 1 90.8 90.8 350F A om. Thick. Inches % Eff. y/4 86.1 X 85.9 3'4 87.8 X 87.1 3/ /4 87.7 X 87.9 1 90.0 1 91.7 1 90.6 1 92.0 1 90.6 1 90.3 1 90.4 1 90.9 1 90.9 1 90.5 1 91.4 1 91.4 * Where low initial investment is of primary importance. TABLE OF RECOMMENDED THICKNESSES* FOR COLD PIPING AND DUAL-TEMP. SERVICE THERMAL CONDUCTIVITY .40 T emperature Up to 14" Pipe Sizes 2" - 3X* 4" 6" 7" - 10" 11" - 24" Chilled Water Ice Water Brine Special Brine .Above 50F 50F to 35F 34F to OF OF to -30F 1" w/r 2" 2-4" 1" 1-4" 2-4" 2-4" 1" 1-4" 2-4" 3" 1" 1-4" 2-4" 3" 1" 1*4" 2-4" 3-4" 6 .20 ^ Based on thicknesses needed to prevent condensation on pipes exposed to ambient conditions of 90 F. and 90fe relative humidity. APPLICATION Thermoglas pipe covering is sawed on one side only. To apply, simply pull the section apart at the seam, slip one end over the pipe and run hand up seam so that section snaps in place. Seams can be closed light with pressure-sensitive mastic tape, staples, siring, canvas and paste, metal bands or other standard fastenings. Thermoglas can be painted if desired. .to 100 200 MEAN TEMPERATURE F. 300 Sizes: Thermoglas is available in onepiece sections made in 3-foot lengths for small sizes. Medium and large sections are furnished in 6-foot lengths. Canvas jackets in several weights are available. HAIR FELT INSULATION industrial insulation DESCRIPTION TABLE OF WEIGHTS Weight per Square Foot--Ounces Standard Hair Felt (Nos. 300 and 301)-- Cattle hair felted and pressed to uniform thickness by steam-heated platens. This type of insulation is distinguished by waffle pattern on one surface. No. 301 is 10% lighter than No. 300. Punched Hair Felt (No. 302)^Cattle hair, felted but not pressed under steam plat ens. Punched with needles to interlace the hairs and give strength to the felt. Hair and Jute Felt (No. 303)--Corabinap tion of jute fibre and cattle hair, felted and punched to interlace fibres. USES Hair Felt is used for insulating coldwater and ice-water fittings, and as a "built-up'* insulation on refrigeration pipes and equipment. Particularly suited for covering irregular shapes. SPECIFICATIONS Thermal conductivity: 0.24. RECOMMENDED THICKNESS Temperature Range 50 to 15 to 0 to -20 to -40 to -60 to -80 to -100 to -120 to 63 F. 50 5 0 -20 -40 -60 -80 100 Multi-Layer Thickness 1" 2" 3" 4" 5" 6" 7" 8" 9" Thickness-in. 1/4 1/2 3/4 1 1-1/2 2 No. 300 4 6-1/4 84/2 11 16 21 No. 301 4 6 8 10 14 18 No. 302 4 6 4/4 8 4/2 11 16 21 No. 305 .. -- -- 000 -- Hot Asphalt Method: First a layer of dry 15-Ib. Feltex Roofing Paper shall be applied to the pipe and secured by a spiral wrapping of jute twine. Then, al ternate layers of \*y thick Hairfelt and 15 -lb. Feltex Roofing are built up to the desired thickness. Each layer of Hairfelt and Feltex shall be heavily coated with hot asphalt and placed on the pipe while hot. Layer of Hairfelt shall be addition ally secured to the pipe with a spiral wrapping of jute twine on 1'* spacings. Canvas, coated with hot asphalt, should be used to seal irregular surfaces. The last layer of Hairfelt is finished with two layers of Feltex applied with hot asphalt, followed by rosin steed paper and canvas jacket. Insulating Membrane Tape Method: Alter nate layers of Hairfelt and Insulating Tape shall be built up to the desired thickness. The Hairfelt shall be cut to the proper length and placed on the pipe dry. Hairfelt to be secured in place with a spiral wrapping of jute twine or light gauge soft annealed wire on 1** spacings. Over each layer of Hairfelt a spiral wrapping of insulation shall be applied lapping the tape at least enough to give double coverage. Each layer of tape shall be painted with a heavy coat of Asphalt sealing paint. Finally, the covering shall be finished with a heavy rosin sized paper and a canvas jacket. Fittings and valves can be insulated in one of the two methods outlined above. In cutting Hairfelt for irregular surfaces it is important that proper cuts are made to eliminate any overlapping or bulges in the insulation. To insure good results Hairfelt should be applied with all joints staggered. At fittings, Hairfelt should be stepped back 2" from the end of the previous layer. To insulate the fittings the Hairfelt should be cut to fill in these "step-backs'* to make the desired broken joint construction. When insulating for below-freezing temperatures, hanger rods must be insulated a minimum of twice the thickness of the required insulation. Note: Refrigeration insulation should be applied only by mechanics skilled in this type work. SIZES AND WEIGHTS No. 300: Standard Hair Felt, standard weight, available in rolls 3' x 50' and 6' x 50'. No. 301: Standard Hair Felt, light weight, available in rolls 3' x 50* and 6' x 50'. No. 302: Punched Hair Felt, standard weight, available in rolls 3* x 50* and 6' x 50'. No. 305: Punched Hair and Jute, light weight, available in rolls 6* x 50*. APPLICATION Applying Hairfelt Covering on surfaces which operate at extremely cold tempera tures places the material under very severe conditions and care must be taken to see that all surfaces are dry before insulation is installed. Hairfelt can be applied in alternate methods. Carey Hair Felt insulation shows why it's particularly recommended for covering irregular shapes. Hair Felt is also used as a "built-up" insulation on refrigeration pipes and equipment. MW-50 INSULATING CEMENT industrial gnsulation USES MW-50 Cement is an excellent monolithic insulation for valves, fittings, expansion joints, heaters, exchangers, access doors, water tube boiler walls, tanks, stills, drumheads and other heated equipment operating at temperatures up to 1600 F. It is particularly recommended for ir regular surfaces due to ease of applica tion. MW-50 Cement bonds firmly to metal, masonry and all block insulations. SPECIFICATIONS RECOMMENDED THICKNESS Temp. -- 0 F ThicknessInches Cross section through MW-50 Cement showing clean, insulating fiber nodules or pellets bonded only at their surfaces. These numerous and minute air films and air spaces provide high insulation value. MW-50 Cement can be used for temperatures up to 1600 F. DESCRIPTION MW-50 Cement is a complete insulating material in itself. Special MW-50 nodular mineral fibers are combined with bonding materials, -asbestos fiber and a rust inhibitor to produce a mixture with ex cellent physical and thermal properties. 100 to 225 225 to 325 325 to 425 425 to 525 525 to 625 625 to 727 725 to 825 825 to 925 925 to 1000 Over 1000 1 1-1/2 2 2-1/2 3 3-1/2 4 4-1/2 5 Consult Carey Packaging: MW-50 is furnished in 5<Mb. and 100-lb. paper bags. MW-^0 Cement in use at Kansas City Power and Light Co., Kansas City, Mo.. Pipes carry saturated steam at a temper ature of 500 to air heaters. Insulation is Carey 85% Magnesia. THERMAL CONDUCTIVITY FEATURES High Insulation Value--More than double that of ordinary asbestos cements. MW-50 mineral fiber has remarkably low heat conductivity. _ Negligible Shrinkage--Fibrous toughness minimizes cracking and shrinkage in drying. Highly Adhesive--MW-50 adheres to both warm and cold surfaces. Economical--One-inch coat of MW-50 Cement insulates 4s well as a two- or three-inch coat of ordinary asbestos cement. MW-50 goes further, too. One 50-pound bag covers approximately 25 sq. ft. to one-inch thickness. A 100pound bag of ordinary asbestos cement covers only about 17 sq. ft. to same thickness. For permanent weather protection, apply Thermotex-B or Insulation Seal over wire mesh or. Fiberflex. MEAN TEMPERATURE P. APPLICATION Add water to MW-50 Cement and mix to a stiff mortar consistency, (This wet mixture can be kept for reuse.) We recom mend troweling on layers of approximately 3/4-inch thickness, one at a time. Each layer should be thoroughly dry before successive layers are applied. When layers over 3/4" thick are applied. poultry wire reinforcement should be in stalled between each layer. Even for nor ma! layer thickness, we recommend one layer of poultry wire before the final coat on large surfaces. Leave all coats with a rough surface, ex cept the last coat which should be troweled smooth. Paint final coat, if desired. MW-ONE INSULATING CEMENT industrial insulation SPECIFICATIONS Finished coat varies from 1/4** to 1/2** thick. Figure MW-One as a part of total insulation thickness. When making up fittings or insulating irregular surfaces use 1/2** thickness for each 100 F., plus 1/2" additional thickness. Packaging: MW-One is packaged 50 pounds per multi-wall Kraft bag. Mixing instructions are printed on each bag. THERMAL CONDUCTIVITY $ K MW-One Insulating Cement, in 50 pound bags, is available only in white lor temperatures to 1000 F. DESCRIPTION Carey mineral wool pellets and other ingredients (including rust inhibitor) are combined in MW-One Insulating Cement to form a monolithic, all-purpose, fast setting finish cement that insulates as well as protects, giving a white surface. FEATURES . Quick, easy, single-coat applicationsaves valuable time and dollars. . Tough, smooth surface-^an be painted. . Negligible shrinkage (Max. 1%)--no hairline cracks. . Fast setting--two to three hours. . Rust inhibilive, noncorrosive. . Fire-resistant, noncombustible. . Excellent cohesion--to all types of insulation. . Many uses inside and out. . Good workability--fast wetting, easy to mix and spread. Very plastic under trowel. . Water resistant. USES For valves, fittings, tanks, ovens, hot air ducts. MW-One can be applied directly over any insulation, or it can be used as a finishing cement for Carey MW-50, 0 200 400 600 MEAN TEMPBUTURE eF. aoo 1000 Carey Industrial Insulation MW-One Insulating Cement PLICATION Mix Ratio: 50 pounds MW-One to 8 or 9 gallons water. Dry mix the material, turning the bag end for end several times to eliminate segregation acquired in shipment on storage. MW-One readily combines with water but does not become saturated. Thus MW-One is easily trowelable and retains its high insulating qualities. Numerous small batches are best and eliminate waste. Clean and rinse the mix box before each batch. Keep the mechanic supplied steadily during application, using sufficient number of clean pails. Surface to receive cement should be free from all dirt, dust, rust, grease, paint or other foreign matter. f One Cement should be applied to ^...m surfaces--not hot. After initial set period of 2 - 3 hours, surface temperature can be raised without affecting cement. Don'* attempt to salvage unused material that has been mixed for the initial set period of time, or add to a previously mixed batch. In applying, hard trowel the material in ^er to secure a good, firm "key" with blocks or one-inch mesh reinforce . Then continue to apply the ma i. j! to the specified thickness required in one coat. Dip trowel frequently in clean water to speed'application. MW-One cement covers approximately MW-One has a variety of uses, inside and out. Recommended for valves, fit150 sq. ft., 1/4" thick, per 100 lbs. tings, tanks, ovens, hot air ducts where temperatures do not exceed 1000. CEMENTS INSULATING AND FINISHING --- ----------rasr-w,- industrial insulation INSULATING CEMENT No. 707 Asbestos Cement: This is a long fiber grade having excellent in sulating value. It is recommended for covering fittings, pointing up blocks and pipe covering, and for a finish coat over block work where an exceptionally smooth finish is not required. LF-20 Cement should be mixed with water and applied in layers 1/4" to 1/2" thick. The first layer should be reinforced with hexagonal wire mesh. This cement is intended for finishing only where specifications call for long fiber cement. Its conductivity at 100 F. is 1.6; at 300 F.t 1.8. ' LF-20 meets Military Specification \1ILC-2908. Furnished in 50 lb. paper bags and 100 lb. burlap bags. No. 100 Asbestos Cement (Hard Finish): Composed of asbestos fibers and bonding clays,. No. 100 Cement is specifically designed to give a hard, smooth white finish oveT block work or other insulation. It should be used only for finish work. No. 100 Cement is mixed with water and trowel-applied in approximately 1/4" layers. The first layer should be rein forced with hexagonal wire mesh. covers approximately 20 sq. ft.. 1" thick, per 100 lbs. No. 100 Cement is furnished in 50 lb. paper bags and 100 lb. burlap bags. Meets Specification AMSC 35 Type PI. No. 303 Asbestos Cement (General L'tilitv h Composed of asbestos fibers and bonding clays. No. 303 Cement is a general utility cement for finishing and pointing up fittings. It sticks to all surfaces and finishes medium hard. This cement is mixed with water and trowel-applied in approximately 1 4" layers. The first layer should be rein forced with hexagonal wire mesh when this cement is used over other insulation. Conductivity at 100 F. is 1.4; at 300 F., 1.9. It covers approximately 10 sq. ft., 1" thick, per 100 lbs. No. 303 Cement is furnished in 50 lb. paper bags and 100 lb. burlap bags. This cement has a minimum of shrinkage. No government specification is issued Conductivity at 100 F. is 1.30. It for No. 303 Cement. This cement is reasonably hard, has superior sticking characteristics, and is effective at temperatures up to 750 F. Its covering capacity is approximately 22 sq. ft., 1" thick, per 100 lbs. Con ductivity at 100 F. is 1.00; at 500 F., 1.34. No. 707 Cement is furnished in 50 and 100 pound bags. FINISHING CEMENT LF-20 Asbestos Cement (Long Fiber): This Cement is composed of long asbestos fibers and bonding clays. It is a medium hard finish cement for final surfacing of insulation where expansion strains are severe, such as over boiler water walls. This cement trowels to a smooth white finish and covers approxi mately 20 sq. ft., 1" thick, per 100 lbs. Carey finishing cements trowel to a smooth, white finish. Improve the appearance of every installation. Carey No. 100 finishing cement provides a hard, smooth surface over block work and other types of insulation. CEMENTS BONDING AND REFRACTORY ea industrial insulation t JDING CEMENT Fibrous Adhesive (Bonding): Composed of asbestos fibers, silicate of soda and filler materials. Fibrous Adhesive is a fibrous plastic cement of thin troweling or brushing consistency* It is designed for laying up insulating blocks, and it makes a very strong heatproof bond that is unaffected by temperatures up to 800 F. Fibrous Adhesive is applied with trowel or brush to approximately 1/8'*thickness, h can be applied either in spots or over the entire surface to be insulated. It can be applied on cold or warm surfaces, but not at temperatures above 200 F. After application it should not be heated over 200 F. for three or four days. C'T its must be kept tightly sealed. In pav ily used containers, a thin film of water should be kept on the surface of the adhesive. ' One gallon covers 25 to 30 sq. ft. of block insulation to approximately 1/8** thickness. Fibrous Adhesive is furnished in 1-gal. pails weighing approximately 12 lbs. gross; 5-gal. pails weighing ap proximately 67 lbs. gross; 55-gal. barrels ' ing approximately 670 lbs. gross. M< Navy Specification 52-C-22 (INT). REFRACTORY CEMENT Carey Hi-Temp blocks installed at Ford Motor Company, Detroit, are finished with 3/4" thick Vitricel cement inside boiler breeching. Vitricel Cement (Refractory Finishing): Composed of asbestos fibers and bonding materials, Vitricel Cement is a dry, semi-refractory hydraulic setting cement for -nperatures up to 1900 F. It is de^, .d for pointing up joints and cracks in stack and breeching lining, covering metal parts exposed to hot corrosive gases, and surfacing block insulation in stalled inside breechings, ducts, econ omizers. Vitricel Cement resists moisture and has a very low drying and heat shrinkage. This cement is mixed with water and applied in layers approximately 1/2** thick. The first layer should be applied over reinforcing mesh, preferably stucco metal lath. Where two coats are required, apply 10 to 12 sq. ft. of the first coat and follow immediately with a second coat before the first one dries. Mix only quantities that can be used within onehalf hour. Apply immediately after mixing. Packages must be stored under conditions as dry as for Portland Cement. Vitricel Cement covers approximately 17 sq. ft., 1** thick, per 100 lbs. It is furnished in 50-lb. paper bags. No government specification is issued for Vitricel Cement. INSULATION EMULSIONS THERMOTEX B, No. 51 and No. 228 EMULSIONS industrial Einsulation aKauttMitfBssMK&iautoim Insulation on vacuum towers and piping is waterproofed with 1/4-inch coat of Thermotex-B. THERMOTEX B DESCRIPTION Thermotex-B is a combination of asbes tos fibres, emulsified asphalt and mineral fillers. It forms a cold plastic water proof coating, which is applied by trowel in one or more coats. FEATURES . Excellent elasticity -- minimizes sur face cracking from temperature changes. Non-burning, fire-resistant. Shipped ready-to-use -- eliminates onthe-job mixing. Good coverage -- 100 pounds covers approximately 55 square feet, full 1/4inch thick wet or 1/8-inch thick dry. Dries quickly. Requires no painting. USES Thermotex-B is recommended as a dura ble, waterproof coating for insulation on hot equipment, ducts, vessels, breech ings, tanks, towers, heat exchangers and fittings that are subjected to weather con ditions. It is especially suited for oil and chemical plant use because it withstands acid and alkaline conditions and can be installed over insulation that is not com pletely dry. Thermotex-B is a breathingtype coating. After application over moist insulation, Thermotex-B allows the trapped water vapor to escape, while remaining impervious to surface water. Thermotex-B is not recommended for equipment operating at temperatures lower than ambient. When the insulated surface temperature is lower than the dew point of the surrounding air, water vapor will form on the surface. This condensation is like ly to penetrate the insulation and cause rusting and deterioration. A cut-back type of weatherproof material should be used on all equipment operating below the dew point of the surrounding air. The following are a few advantages of an emulsion such as Thermotex-B over cut-back materials: 1. Will not blister. 2. Will not run or sag as easily as cut backs. 3. No odor. 4. Non-flammable. 5. Can be applied over a moist surface. SPECIFICATIONS Meets Specification AMSC-35 Type B3. Packaging: Thermotex-B is furnished in 45-lb. pails, 270-lb. drums, 470-lb. drums. Plastic liner protects Thermotex-B from electro-chemical reaction in drum to as sure proper consistency. After drum is open, liner can be re-tied to preserve unused Thermotex-B. Handling: Thermotex-B should be protect ed against freezing during storage and during application. APPLICATION Thermotex-B should not be applied during wet weather or when temperatures are freezing or near freezing. Temperatures must remain above freezing until Thermotex-B coating is thoroughly dry. When applying Thermotex-B over a nonporous surface such as steel, a prime coat of Carey Ebontex Primer should be spread thinly over the surface. This should be followed immediately with Thermotex-B. Primer is not required when Thermotex-B is to be applied over asbestos cement or other absorptive insulations. One-inch mesh poultry wire should be secured over the insulated surface. A skin coat is usually troweled on the wire, followed immediately with the main coat of 1/4" thickness. (After drying, the main coat will shrink to about 1/8*' thickness.) While troweling, brush with water to ob tain final smooth surface. For a hard surface, mix two or three parts of clean sand with one part of Thermotex-B. NO. 51 EMULSION DESCRIPTION An odorless, non-inflammable clay tvo< emulsified asphalt composed of asphalt water and bentonite clay. CONSISTENCY: Troweling. If necessary to thin, ad< small amount of cool, clean water stirring rapidly. USES 1. As a prime and bond coat for insula tion and cold storage vault and othe low temperature insulated construction 2. As a bond coat for cementing layer: for vapor barrier and aluminum foi to walls and ceilings. Mixes well witi Asbestos Fibre and sand to make "os the job" finished coats. 3. Can be used to make asphaltic morta by mixing 6 parts of No. 51 Emulsion 1 part of Portland Cement and 1 par water. COVERAGE 1 gallon per 20-25 sq. ft. for bonding insulation. 1 gallon per 100 sq. ft. for priming. 1 gallon per 50 sq. ft. for bonding vapoi barrier sheets. Must be stored at temperatures above freezing. NO. 228 FIBRATED EMULSION DESCRIPTION An odorless, non-inflammable composi tion of bentonite clay type emulsiiied asphalt .and asbestos fibre similar to Thermotex-B. CONSISTENCY Trowel. USES 1. Weather proof coating to protect insu lation exposed to weather, chemical fumes and liquids, applied to win mesh stretched over insulation. 2. On insulated air conditioning ducts as a coating or for `'running the seams" on rigid duct insulation. 3. Can be used as a protective damp proofing coating on foundation walls and perimeter insulation. 4. Mastic finish coat in cold storage vault construction. COVERAGE Head of vacuum distillation unit has 1 gallon per 6 sq. ft. produces a dry Thermotex-B applied over insulation. thickness of 1/8". CORK-COTE MASTIC Industrial insulation aulating and weather-resistant coating applied directly to the primed metal surface. Can be troweled, brushed or sprayed. DESCRIPTION /",*'rey Cork * Cote Mastic is an asphalt * mastic containing a high percentage -anulated cork. It may be applied w*n a trowel, brush or spray equipment. It is normally applied, to a thickness of H' or H The mastic film protects equipment from weather and corrosion and decreases the possibility of conden sation forming on the equipment. It also serves as a sound-deadener on ducts and ' ->r equipment. Carey Cork - Cote Mastic being applied on a well water line at American Oil Com pany's plant in Destrehan, Louisiana. USES , Carey Cork Cote Mastic is used by the refinery, chemical and petro-chemical in dustries as an anti-sweat insulating and weather-resistant coating applied directly to the primed metal surface. It may be used on fractionation towers, oil or water storage tanks, duct and pipes, or on other equipment where an inexpensive coating is needed to help reduce con densation, help prevent corrosion and protect against weather. PHYSICAL PROPERTIES Linear Shrinkage: None '"hickness Shrinkage: 10--20% 'erages: ich .... 12 gals per 100 sq. ft. h mch .... 20 gals per 100 sq. ft. Weight Per Gallon: 6.4 lbs. Flashpoint: 100 F. APPLICATION Temperature of the material during ap plication should be between 50 F. and 80 F. For spray application the oper ating air pressure on the material should be 20 to 50 lbs. A desired thickness of application must be accomplished in one application. LIMITATIONS Storage for periods more than 90 days will cause difficulty in spray application as the consistency increases slowly in storage. The container should be covered when not in use and kept away from open flame or heat. Ventilation should be pro vided when working in closed spaces to remove fumes. Special mastic film protects equipment from weather and corrosion and de creases the possibility of condensation damage. 40 INSULATION SEAL ^industrial ^insulation DESCRIPTION Insulation Seal is a ready mixed asbestos fibrated bituminous mastic.Itis especial ly compounded for cold application over most types of insulating materials. It protects the insulation against damage and loss of efficiency by the penetration of water and water vapor. Insulation Seal is made in spray (No. 820) consistency or trowel (No. 830) consistency. USES Insulation Seal can be used on pipes, curved and flat surfaces of all kinds. It will hold its bond on horizontal, vertical, sloped or inverted surfaces, insulation Seal is designed for application over in* sulation such as 85% magnesia, asbestos cement, rock wool base cements, cellu lar glass, fibre-glass, mineral wool blan kets. It remains flexible and will with stand moderate expansion and contraction without cracking on interior or exterior surfaces. Insulation Seal is specially recommended for (1) systems operating at temperatures below dew point, (2) dual temperature sys tems, and (3) systems subject to long shutdown periods. It should not be ap plied to surfaces subject to temperatures in excess of 250 F. recommend spraying or troweling a first coat using about 3 to 4 gallons per 100 square feet. Then, a layer of Glass-Fab (asphalt bonded glass fabric) should be imbedded in the Insulation Seal. The second coat should be appliedusing about 3 to 4 gallons per 100 square feet. Carey Insulation Seal starts to set im mediately after application. It dries uni formly throughout and becomes a tough, firm plastic film in 9 to 10 days on in door installations. Outdoor installations may take more or less time, dependin. upon weather conditions. Caution: Open fires or welding shouh not be permitted in the area while coat ing is being applied or drying. Do no use solvents for thinning. For ease o application the best workable temperatur range is 50 F. to 100 F.t hence it it advantageous to store in warm room dur ing cold weather. Do not heat the con lainer above 100 F. 8ths 16ths FILM THICKNESS AND COVERAGE Approximate Square Feet per 32ds 64ths Gallon Approximate G allons per 100 Sq. Ft. 1 103.00 12 51.2 3 35.4 1 24 25.6 5 20.5 36 17.1 7 14.7 0.97 1.95 2.82 3.90 4.87 5.84 6.81 12 4 8 9 5 10 11 3 6 12 13 7 14 15 12.8 11.4 10.3 9.34 8.54 7.87 7.35 6.85 * 7.79 8.76 9.74 10.70 11.70 12.7 13.6 14.6 SPECIFICATIONS Laboratory tests reveal that Insulation Seal is an excellent moisture barrier. Its penetrative moisture vapor per 24 hours per square foot equals only 0.0001 ounce of water. Thickness will shrink 10% to 12% in drying (due to loss of solvents), but there is no lineal shrinkage. One gallon covers about 13 square feet of surface to a finished 1/8-inch thickness. Packaging: Insulation Seal is packaged in 54-gal. drums, 5-gal. pails, 1-gal. cans. APPLICATION All surfaces to be coated with Insulation Seal should be free of moisture, dirt, oil, rust and other foreign matter. During ap plication, temperature should not be above 130 F. for outdoor equipment, and not above 100 F. for indoor equipment. Best results are obtained when surround ing air temperature is between 50 F. and 100 F. Below-freezing applications can be made if surface temperatures are heated to prevent frost. 24 8 16 17 9 18 19 5 10 20 21 11 22 23 6.41 6.02 5.68 5.40 5.13 4.88 4.65 4.41 3 6 12 24 25 13 26 27 7 14 28 29 15 30 31 4-27 4.10 3.94 3.80 3.66 3.53 3.42 3.31 4 8 16 32 3.20 Note: Shrinkage of 25% can be estimated to obtain dry film thickness. 15.6 16.6 17.6 18.5 19.5 20.5 21.5 22.4 23.4 24.4 25.4 26.3 27.3 2 8.3 70.? 30.2 31.2 Fittings of dual temperature systems should be built up with layers of hairfelt and insulating tape and then coated with Insulation Seal. When applying Insulation Seal over 85% Spray application of Insulation Seal on Finished breeching duct at TVA stean Magnesia blocks and pipe covering, we outside breeching duct. plant, Paducah, Kentucky. BTU CEMENT -f industrial Insulation D-jCRIPTION Carey BTU Cement is a ready mixed asbestos fibrated bituminous mastic of a troweling consistency. It is especially compounded for cold application to ex terior surfaces of porous masonry walls. It produces a firm, tough, air-impervious plastic film which effects an air-tight seal, preventing infiltration of cold air through mortar joints, porous masonry and structural cracks. USES BTU Cement can increase boiler effi ciency and save as much as 10% on fuel bills when it is used for sealing the out side walls of brick boiler settings. It / can be used in power plants, boiler rooms, factories, apartments, hotels and institutional buildings. SPECIFICATIONS Laboratory tests show penetrative mois ture vapor per 24 hours per square foot equals 0.0001 ounce of water. Coverage--40 lbs. to 100 sq. ft., 1/16inch thick coating. We recommend a heavier coating up to 1/8 inch thick for old and very porous settings. APPLICATION Note: Do not use solvents for thinning. For ease of application the best workable temperature range is 50 F. to 100 F., hence it is advantageous to store in warm room during cold weather. Do not heat container above 100 F. Clean brick or masonry with a stiff broom or wire brush. If necessary, point up ail badly defective mortar joints with fresh mortar. Trowel BTU Cement well into all mortar joints and cracks. Point up care fully around cleaning doors, drum heads and openings. During application of the coating, the surface temperature should not be above 130 F. for outdoor equip ment and not above 100 F. for indoor equipment. Caution: Open fires or welding should not be permitted in the area while coat ing is being applied or drying. FIRECLAD JACKETING Industrial insulation SPECIFICATIONS PHYSICAL PROPERTIES PRODLCT CAREY FIRECLAP Weight Per Roll 108 sq. ft. Approx. 50 lbs. Approx. 50 lbs. Tensile Strength, Lb. With 49 87 Across 33 52 Tear Strength, W. Grams 1564 3200 plus Pliability on Mandrel at 77 F. Cracks, cm. Passes, cm. 6 7 5 6 Wire Cutting Test Time to make 3** cut 41*27" 240*00*' plus 10 lb. weight, No. 18 wire , Carey Fireclad is a durable, weatherresistant jacketing specifically designed Match Test 7 drops No drops for the protection of outdoor insulated pipe lines where the danger of fire must " Product "A** -- A jacketing widely used and generally considered as being most be minimized. Ordinary roofing jackets highly fire-resistant. are not satisfactory, because they burn, spread fire, and drip asphalt, which furth Packaging: Carey Fireclad comes in rolls lateral laps. On horizontal pipes, the er contributes to combustion. 38" wide by 34*6" long, containing 108 laps should be located on the side of the DESCRIPTION Carey Fireclad consists of a tough, sub square feet; and weighs approximately 50 lbs. per roll. When in storage, keep in dry place. Stack on end not over three rolls high. pipe, turned downward. The jacket mav be held securely in place with rings of No. 16 ga. copper weld wire or strapping on not greater than 4 to 6" centers -- stantia] sheet of asphalt saturated as bestos felt, over which is cemented on one side an unsaturated asbestos sheet. The complete sheet is reinforced with a fabric of tough, flexible glass threads. This construction combines flexibility with very high tensile strength and ex APPLICATION Carey Fireclad Jacketing should be ap plied with the white side out on all straight runs of pipe or expansion bends with at least 3-inch circumferential and with one wire ring placed over each cir cumferential lap. No lap cement should be used. In cool weather (below 50 F.) store overnight in a warm place before unroll ing. tremely great resistance to tearing and cutting from wire or strap fastenings. It offers many "plus'* advantages as jacket ing for outdoor insulated pipe lines. . USES Carey Fireclad is recommended for use in the process industries and in oil re fineries, where it affords maximum re sistance to the spread of fire -- and further protects the insulated surface from weather damage. FEATURES . Will not drip asphalt in the presence of fire nor support combustion. . Water-repellent white surface assures long life, maximum efficiency. . Greater width reduces labor cost -- means fewer application joints. . Will not crack when applied over small size pipe covering. . High tensile strength. . Reinforced with a fabric of tough, flex Carey Fireclad is widely used in oil refineries. Resists fire, protects insulated ible glass threads. surface from weather damage. ' WEATHERPROOF JACKETING MATERIALS industrial i linsulation [ ASBESTOS ROOFING FELT An excellent uncoated asbestos roofing for jacketing high temperature insulated pipe lines where high temperatures may cause running and dripping of a coated roofing. Consists of 2 asphalt saturated asbestos sheets combined with asphalt. Surfaces are black. Has good flexibility to conform to small radius curvatures. Carries Underwriters* Class "C** label. Weight -- 45 or 55 lbs. per square. Furnished in rolls 36 in. wide containing ^IOR sq. ft. (one square). SATURATED ASBESTOS ROOFING FELT An asphalt saturated asbestos felt rec ommended for underground pipe cover* ings. The felt weighs approximately 15 lb. per 100 sq. ft. A double wrap ''ly construction is recommended. Is available in 20 lb. per 100 sq. ft. ht for application in one layer on the job. Furnished in rolls of 324 sq. ft. Carey Roofing jacket Covering shown on outdoor pipe lines at Houston, Texas Power and Electric Corp. plant. These felts can be factory applied to Asbestos Sponge, Careycel, Impervo and Protecto coverings. They can be fur* nished with, but not applied to, 85% Magnesia and Alltemp. 6** wide collars covering butt joints and waterproof 'Cw^ient and wire for application will be supplied in each case. 15 lb. Felt meets: ' Federal Specification HH-F-185 Class A Type 11. Navy Specification 7 Yg-AA-15. 20 lb. Felt meets: Federal Specification HH-F-182 Class A. Navy Specification 7 Yg-AA-20. ORGANIC ROOFING JACKET COVERINGS For outdoor pipes. Prepared roofing jackets attached to pipe coverings at the factory are the least expensive form of waterproofing. MuIti*Ply, Asbestos* Sponge, Careycel, Impervo and Protecto coverings can be furnished with such roofing jackets attached, including 6*in. wide collars for covering butt joints, and waterproof cement and wire for appli* cation. These jackets can be furnished with, but not attached to, 85% Magnesia and Alltemp coverings. For outdoor ex* posed pipes Carey Surety Roofing jacket* ed coverings are regularly supplied. For pipes running in closed conduits under* ground, double layer Saturatea Asbestos Roofing jackets are recommended. All weatherproof jacketing materials can be furnished in bulk unattached to pipe covering, with accessories for applying. ASBESTOS MILLBOARD industrial insulation USES SPECIFICATIONS Asbestos Millboard is used extensively in the electric heating field and glass industry. It is recommended for use in fire screens and partitions, as a fireproof lining for ceilings, walls, floors, elevator shafts, moving picture machine booths, ranges, stoves, grates, electric ovens, sterilizers and roasters. Both No. 1 and No. 7 grades of Asbestos Miliboard meet Federal Specification HH-M-35U. Sizes: Asbestos Millboard is furnished in 42" by 48" sheets in thicknesses from 1/32" to 3/4". Packaging: Asbestos Millboard is packed in 100-lb. canons unless otherwise specified. TABLE OF THICKNESSES AND WEIGHTS FOR NO. 7 GRADE* r i Carey Asbestos Millboard is lighter in weight than other millboards...has higher insulation value per pound. DESCRIPTION Asbestos Millboard is made from pure Canadian asbestos fiber pulp which is mixed with binding materials and formed in sheets. Commercial Millboard is avail able in two grades. No. 7 Medium and No. 1 Hard. The No. 7 grade withstands temperatures up to 800 F., and the No. 1 grade withstands temperatures up to 1000 F. Though these two grades satis fy the vast majority of requirements, special grades can be developed by Carey laboratories. Millboard with pin-point (knurled) finish can also be supplied. ThicknessInches 1/32 3/64 1/16 5/64 3/32 1/8 5/32 3/16 1/4 5/16 3/8 1/2 5/8 3/4 Per Sheet Pounds ** 2.0 2.8 3.85 4.8 5.82 6.93 9.0 10.35 14.01 17.5 20.28 26.53 34.3 39.8 . * No. 1 grade weighs approximately 10% more than No. 7 grade, **Correct to + 10%. Per Sq. Ft. Ounces 2.3 3.2 4.4 5.5 6.6 7.9 10.3 11.8 16.0 20.0 23.1 30.3 39.2 45.5 ASBESTOS SHEETS AND PANELS industrial insulation INDUSTRIAL A-C BOARD This board is composed solely of Port land cement and asbestos fiber. It is fire-resistant and actually becomes stronger with age. Industrial A-C Board is unaffected by most acids and alkalies, heat and cold. It is rot-proof, verminproof, termite-proof, rodent-proof, and it does not corrode. Having a natural ce ment gray color. Industrial A-C Board does not require protective coatings or paint, although it can be painted if de sired. This board withstands temperatures up to 800 F. Industrial A-C Board is available in standard sheets 42** by 48", 48" by 48". 42" by 96". and 48" bv 96" in thick nesses of 1/4", 3/8" and 1/2". THERMO-BORD Thermo-Bord is composed of 1/8*' as* bestos-cement board bonded to both sides of a special asphalt-impregnated type insulation board. The bonding material is moisture resistant, forming a vapor barrier between the asbestos-cement board and insulation board. Thermo-Bord is recommended for roof decks, outside walls, partitions, and low-temperature ovens (not over 200 F.). Standard sheets are available 4* wide in lengths of'6*, 8*, 9*, 10* and 12*. Overall thicknesses: 3/4", 1-1/8", 1-9/16** and 2". 4.2 CAREYSTONE CORRUGATED SHEET ASPHALT PLYBOARD Asphalt Plyboard is laminated from altemate layers of asphalt-saturated felt and a specially developed thermoplastic asphaltic material. It replaces wood, ply wood, hardboard, meta's, plastics, composition boards, fabricated krafts and allied products. This extremely pliable board is easily nailed, cut, stamped or punched. Asphalt Plyboard is a versatile and in expensive construction material for basement ceilings, temporary flooring, farm storage bins and animal house", and auto trunk boards, Asphalt Plyboard is manufactured in thicknesses from 1/16" to 3/8"; widths up to 60** and lengths up to 120*'. Facilities are available for special lengths up to 144". Careystone Corrugated is made from Portland cement and asbestos fiber, compressed under enormous hydraulic pressure to form a homogeneous mono lithic sheet. Careystone Corrugated actually becomes stronger with age. These sheets are excellent for roofing and siding on industrial and commercial buildings. They are also widely used as a decorative building material. Careystone Corrugated sheets have 10 corrugations in a 42-inch width. Sheets are available in standard lengths from 1* to 12' in multiples of 6". The aver age thickness is 3/8**. Average weight per sq. ft. bulk is 4 lbs.; weight per sq. ft. crated is 4-1/2 lbs. Carey Industrial Insulation 'EFOIL BOARD r.<efoil Board consists of successive plies of corrugated asbestos paper bond ed with a special fire^esistant adhesive, treated with a chemical and hardened to make a strong, fire-resistant, waterresistant board. It is easily sawed and drilled with ordinary hand tools. Firefoil is recommended for interior use only, in such applications as bulkheads, air-conditioning housings, and oven en closures. Firefoil withstands tempera tures up to 1000 F. Standard sheets are 4' by 8*, available in thicknesses from 1/2" to 1" in 1/8** multiples, and from 1" to 3" in 1/4** multiples. Approximate weight is 1 lb. .per sq. ft. per 1/2** of thickness. Asbestos Sheets and Panels SPUN MINERAL WOOL DUCT INSULATION findustrial ^insulation DESCRIPTION Career Ooct Insulation is made in semi-rigid sheets, pro cessed from long fine fibers of spun mineral wool. Light in weight, with a density of approximately seven pounds per cubic foot, this insulation is easily handled and quickly installed. It provides a high degree of thermal efficiency as indicated by the accompanying table. FEATURES Moisture Resistant -- made of spun mineral wool fibers that will not absorb moisture, Carey Duct Insulation is non-capillary in character. If the surface accidentally be comes wet, it can be dried off rapidly without affecting its original properties and can be applied at once. Non-Corrosive -- this insulation, inorganic in composition, does not cause corrosion of metal duct surfaces. Workability -- Carey Duct Insulation is easy to cut with a knife to conform to irregular flat shapes. Far curved sur faces, it can be quickly scored for bending either way to match the contour of the doct. Non-Irritating to Handle -- Carey Duct Insulation has a smooth, clean surface and is free from loose particles. It can be handled with bare bands without discomfort. Finish -- Carey Duct Insulation may be brush or spraypainted, or coated with weatherproofing compounds. Underwriters' Laboratories -- Both plain and coated Carey Duct Insulation have been tested and rated by Underwriters' Laboratories. USES Carey Duct Insulation, for air conditioning ducts and heat ing ducts, is available plain, with factory-applied vapor barrier, neoprene coating or foil-faced. Carey Duct Insulation with vapor barrier -- Recommended for use in warm, humid areas where condensation is a factor. Vapor barrier is applied at the factory and consists of 40 lb. black kraft paper coated with asphalt. Carey Duct Insulation with neoprene coating -- This coat ing on one side with neoprene compound prevents fiber entrainment. Applied inside of ducts as a lining, it reduces fan noise and prevents its transmission by the moving air into areas served by the system. Where applied to the ex terior, the coated side facilitates painting. Foil-Faced Duct Insulation -- This duct insulation is faced on one side with .001 aluminum foil laminated to SO-pound flame-resistant Kraft, 2x2 scrim and flame-resistant adhe sive. The maximum temperature limit is 250 F. Thermal Conductivity: "K" .24 at 75 F. mean temperature. Perme ance to Water-Vapor: Less than .25 perms under ASTME-9653T Method "C". SPECIFICATIONS THERMAL CONDUCTIVITY (K Factors at Mean Temperature F.) 0 25 50 75 1" Thick .21 .22 .23 .24 . 25 100 .29 200 SOUND ABSORPTION COEFFICIENTS (Frequencies) 125 250 500 1000 1" Thick .32 .58 .70 .93 .95 2000 .80 N Thickness Pieces Square Ft. PACKAGING Plain or Coated In Cartons Vapor Barrier In Paper-Wrapped Bundles 3/4" 1" !%' 2" 16 12 8 6 128 96 64 48 3/4" 1" ifc" 2" 8 64 3 64 48 32 24 Size: 24" x 48". Density: Nominal 7 lb. per cu. ft. Maximum Temperatures: Plain Carey Duct Insulation is suitable for insulating surfaces up to 450F. With the vapor barrier it is not normally used in hot areas and naturally should not be used at temperatures in excess of 150E. because the asphalt may soften. ASBESTOS PAPER AND ROLLBOARD Industrial insulation from hard, rocky particles. This pure asbestos pulp is mixed with a small quantity of very strong binding material, formed into endless sheets of different weights, thoroughly dried, calendered to a smooth finish and put up in rolls ready for shipment. Asbestos Paper and Rollboard are strong, flexible, fire-resistant sheets. SPECIFICATIONS Asbestos Paper and Rollboard is fur nished in standard widths of 18", 24". 36" and 37-1-2" in rolls weighing ap proximately 25, 50 and 100 lbs. For manufacturing purposes, jumbo rolls of 200 to 400 lbs. are furnished. Special sizes can be made to order. Asbestos Paper tape, made from standard 12-lb. stock, also is available in 2" and 3" widths. USES Asbestos Paper and Rollboard is fur nished in many weights to meet varying insulation requirement'. DESCRIPTION Asbestos Paper and Rollboard is com posed of pure Canadian asbestos fiber, which is slurried to a pulpy mass, free Commercial Grade Asbestos Paper is entirely satisfactory for most purposes. The 6-pound and 8-pound papers are used extensively in the manufacture of various pipe insulation and electrical insulation. The 10-pound and 12-pound papers are used for wrapping hot air furnace pipes. Heavier weights are used for lining stoves, ovens, gas ranges and for making gaskets, filters and discs. Table of Weights and Thicknesses Lbs/100 Sq Ft ( t 10%) Approximate Thickness-~!n. 4 lb 6 lb 8 lb 10 lb 12 lb 14 lb 16 lb 1/16" (32 lb) 3/32" (48 lb) 1/8" (64 lb) .010 .015 .019 .022 .027 .029 .032 .0625 .093 .125 Carey Rollboard used as a tank lining, Rollboard is strong, flexible, easy to install -- fits a variety of installations. CORRUGATED ASBESTOS PAPER Industrial | insulation i DESCRIPTION SPECIFICATIONS Corrugated Asbestos Paper is made by bonding a sheet of corrugated asbestos paper to a sheet of flat asbestos paper. It is a very light and flexible insulation. Sizes: Corrugated Asbestos Paper is furnished in coarse corrugations 1/4" thick per ply (Aircell), and in fine cor rugations 1/6" and 1/8" per ply. Rolls 36" to 37" wide are available in 250 sq. ft. and 500 sq. ft. sizes. USES Corrugated Asbestos Paper is recommend ed as a wrapping for curved surfaces, such as hoi air furnace pipes and hot air ducts in blower systems used in heating and ventilating large building. Packaging: Aircell (1/4" deep corruga tions) Corrugated Asbestos Paper is packaged in cartons 18" by 18" by 38", weighing approximately 50 lbs. gross. A box car holds approximately 400 cartons. Carload quantities of 500 sq. ft. rolls can be shipped in bulk. These rolls are protected by a wrapping of Kraft paper secured with gummed tape. f \ V REFERENCE DATA y & v foe*. m u ltip ly *4 l i Io m m in t* b U b y th u facioc T b Ic i w p tt *q I t o# p ip * iu i4 ( fo r p p n U rfftr i Km 2 4 ' can b * cofti4irad iH * M m * u t in la n w fo r th o 24* pip* e = < *- y - - - '-- - ----- ' - N s *4 44 44 5 IS 44 is is is 5 - 44 IS y S a a s 8 *4 = S s s a 3 s 2 44 8 3 a -N *4 *s s 44 44 is 44 44 s s P4 s ~ s s s - - 8S 2 3 a fON- 3 8 S 8 3 3 44 9 3 2 3 9 = *4 = s s 8 8 8 8 8 8 44 8 44 8 8 8 8 8 S 3 8 8 s 3 *4 a s 3 8 2 s 4444 8 2 2 8 3 8 > 8 3 S a ; 2 a *4 8 2 O 8 3 Q 3 3 3 9 C 2 2 40 2 2 S - 3 ; Ss a s s Px 2 = O O 8 8 8 m 2 *. *v Px is 8 3 J* a85-2S 3a 9--- * sO - 0 4U> l* 3 75 < E1 -T3 C 1 a1 03 a| & "5 2 9 75 ie wu >2 <9 u. X& j 1 2 ot X 5 i2 u0 u* i t/5 o 9 s a g u. 9 s <j c a aJ g e a s a ? 8 u. e a O i i a s a s $ s 2 C4 8 3 hx 3 3 9 3 8 C 2 -- 3 S' 4X yx 2 a 5 * 2 8 3 a 8 8 - 3 5 3 s x 8 IH = 8 s a 3 9 S 8 * 2 s *3 ~ 3$ * ^4 IS - 44 - * - 8 8 O 8 3 8 is is 44 44 44 44 * a -- = i a J 2 S 2 a IS 44 I4S4 2 - 8 - s 3 3 8 s -- 3 3 ; 2 8 e ft O s 2 2 o o 3 s 8 3 8 a 2 Is 3 3 3 4X 3 o 8 ; a a is 44 8 4| 9 a 8 3 3 8 2 O' o> 4* 2 3 lx. 3 * m 44 a 8 4y ----3 < a > PS Ps 4 4* 44 $ PS 3 a = 5a 3 3 #* 3 x P4 44 44 = 0 8 3 3 '* 4H (X, - ~ *- * * ~ * - * * 2 o g 3 8 3 8 2 IS S 3 S 2 IS 3 2;3a '* ** $; 2 3* 4 IS 8 2 O s8333a832 * 4 -> - * h 2 Px 3 a a = 3 3 5 - a 3 * yx y x * " 14 44 8 = 8 8 3 3 3 a s - $ 3 3 3 *4 a - 3 23 9 2 8 x 4 - * - - 9 - 0 3 2 3 a 2 8 -- 3 a- O 2 3 2 8 8 2 8 (9 i) | =a="8 2 8 Py s 3 8 3 = = 8 = 3 X o 8332 % 3 3 aa a332-am3 S a 8 a ~ 8 ?? 8 i < 3 9 2 2 4 a 5 = = 2 - 44 = 8 3 a ** S a 8 - a 8 Px 2 2 8 * -- -* " ~ A y *>4 * 4| * 14 ~- m3 a g " 2 #4 2 IS P4 "* 44 3 IS 4g s 44 44 5 IS 2 4 44 - * s s 3 a ^4 * 3 2 44 3 2 a 4* ** *4 *4 ** 14 14 ** 44 iy 44 * 44 ** -* a 5 a2: 8 -288Oe8932 *9 A* *4 ** " *4 44 ** 4 "* 44 44 4| - - - - s 8 3 a 8 rs 5 3 g 2 44 8 3 3 3 ** ** 3 - a = 5* 3 - ___ 28 t ys o> *AN 2 3 tt 1 2 i 8 9 3 8 2 a -- -- . -- -- -- 4 44 44 # * "* " *8 1 8*1 >S * i* 2* - y* sp ~ " * IS * ** 1 s 8 - M i H-sf zJiZs 5 i E S i 803 7 1 t t J 8 3 'T o h <# lo im p*< f .I B \ r n ( C' HEAT INSULATION FOR HIGH TEMPERATURES Thermal Tables BULLETIN 101 BX BETTER PRODUCTS FOR INDUSTRY SINCE 1873 THE PHILIP CAREY MFG. COMPANY Gtmral Office -- LOCKLAND. CINCINNATI OHIO Branches la All Principal Cities )' I Even 48 hours of "soaking heat" at 1600 F... cause undue shrinkage or cracking of new CAREY ALLTEMP insulation! ALLTEMP is a special combination of inorganic silicas and asbestos fibers, with physical and chemical properties giving excellent ef ficiency in heat saving and very low shrinkage (up to H less than many 1200* F * 1500 F insulations). It is non-brittle, easily workable and keeps its high thermal efficiency and strength, even through continuous exposure to excessive heat and moisture. ALLTEMP is made in sectional, tri-sectional and segmental blocks. In "nesting" pipe covering sizes, a wide range of unusual assemblies can be built-up from a limited number of "prime" units, with application in either single or broken joint double layer construction. Use it for temperatures from 100 to 1600 F for top efficiency in keeping heat on the job. Other famous insulation products developed by Carey include Super Light 85% Magnesia, Hi Temp No. 19, Tempchek, MW-50 and Mw-One Insulating Cement ana a complete line of bonding and fin ishing cements. There is a Carey-approved contract unit conven iently located to work with you in selecting the insulation most suitable for your needs, and assure its use to best advantage. Con sult your telephone directory, or your nearest Carey district office. The Philip Carey Mfg. Company, Lockland, Cincinnati 15, Ohio. Plants: Cincinnati and Middletown, Ohio; Wilmington, II!.; Memphis, Tenni; Perth Amboy, N. J.: Houston. Texas: Plymouth Meeting, Pa.: lennoxviile, P. Q.; East Broughton, ?. Q.; Research Center, Cincinnati, Ohio. Subsidiary Companies: General Magnesite 4 Magnesia Co.; Quebec Asbestos Corporation, ltd.; The Philip Carey Company, ltd. 'he Lehon Company. can count on divarsifiad product* and sarvkas for industry, farm and homo smco 1873 Pipe Size In. % y* i VA V/2 2 3 4 5 6 COMBINATION COVERING FOR 600 F. * Indicates Recommended Combinations INNER LAYER CAREY AUTEMP, OUTER LAYER SUPER-LIGHT <5% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 2 Hs l 2H 2% *1% 1*% 1*56 l1^ *1% 1% 1% 1% *1% m m i% VJ6 M W m 1H Outer Layer Thickness Inches None None None None None 1% VJ4 2% 2% 3*6 1M 234 2% 3% 1% 2% 2% 3H 1% 2J4 2% 3H l1^ 2% 2**6 3H Temp. F. at Inner Magnesia Surface 298 329 357 380 393 343 376 394 409 356 382 403 421 368 396 422 470 378 399 429 443 Canvas Temp. F. with Air at 80 F. 115 118 118 124 118 116 108 102 100 98 111 106 103 101 112 107 103 100 115 109 104 98 116 108 105 102 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 79 626 91 772 98 950 115 1,190 111 1,350 111 1,670 102 1,670 88 1,670 84 1,670 80 1,670 105 2,420 112 2,420 104 2,420 97 2,420 146 3,070 132 3,070 120 3,070 109 3,070 168 3,750 150 3,750 131 3,750 97 3,750 190 4,440 152 4,440 149 4,440 137 4,440 Percent Eff. % 87.3 88.2 89.6 90.3 92.0 93.3 93.8 94.7 95.0 95.2 95.6 95.4 95.7 96.0 95.2 95.7 96.0 96.4 95.5 96.0 96.5 97.4 95.7 96.5 96.6 96.9 P*ge 3 Pipe Size In. 8 10 r 12 14 16 18 Flat COMBINATION COVERING FOR 600 F. * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches * l1^ 1% i1^ il% v%. *m v% V% 1% MH IA lH - iy2 1H Wo IA *W2 w w m * W2 IA m lH Outer Layer Thickness Inches 256 25A 356 IA 2 2A 3 IA 2 2A 3 IA 2 2A 3 1A 2 2A 3 1A 2 2A 3 IA 2 2A 3 Temp. F. at Inner Magnesia Surface 376 412 431 444 380 408 430 446 386 410 428 450 402 424 446 460 403 426 448 462 404 429 451 464 414 445 466 481 Canvas Temp. F. with Air at 80 F. 118 111 107 104 120 114 109 105 120 115 110 107 122 117 112 108 124 118 113 109 125 119 114 109 123 117 113 109 B. T. U. Loss Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 230 5,710 196 5,710 176 5,710 164 5.710 270 7,040 239 7,040 213 7,040 191 7,040 304 8,320 274 8,32C 247 8,320 223 8,320 340 9,050 307 9,050 271 9,050 245 9,050 390 10,300 344 10,300 302 10.300 268 10,300 438 11,560 373 11,560 330 11,560 283 11,560 73.1 2,590 62.2 2,590 54.2 2,590 48.0 2,590 Percent Eff. % 95.9 96.5 96.9 97.1 96.1 96.6 96.9 97.2 96.3 96.7 97.0 97.3 96.2 96.6 97.0 97.3 96.2 96.7 97.0 97.4 96.2 96.8 97.1 97.5 97.2 97.6 97.9 98.1 Peg* 4 1 ! p*p Size In. Vi % 1 VA VA 2 3 COMBINATION COVERING FOR 700 F * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 2*5 1*% m m 2*e v%. v%. ij% *1% i% 1% *i% i% *i% i>% *1H lM 1H 1H Outer Layer Thickness Inches None None None None None 1% 1*% 2% 2% 3*6 2% 2i% 3% 11% 2% 21% 3% 11% 2% 2i% 3M 11% 2% 21*6 3H Temp. F. at Inner Magnesia Surface 345 383 415 442 457 400 436 459 475 415 447 470 490 429 461 492 540 440 473 500 515 Canvas Temp. F. with Air at 80 F. 122 126 126 132 126 123 114 108 105 101 118 112 108 104 119 113 109 104 122 115 109 102 124 115 111 107 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 102 878 117 1.080 126 1,340 149 1,680 143 1,900 141 2,350 127 2,350 113 2350 110 2350 99 2,350 144 3,400 141 3,400 131 3,400 122 3,400 184 4320 165 4,320 150 4,320 137 4,320 211 5,300 189 5,300 164 5300 125 5,300 239 6370 199 6370 186 6370 172 6370 Percent Eff. % 88.4 89.2 90.6 91.1 92.5 94.0 94.6 953 95.3 95.3 95.7 95.8 96.1 96.4 95.7 96.1 96.5 96.8 96.0 96.4 96.9 97.6 963 96.8 97.0 973 P*e 5 Pipe Size In. Yz % 1 VA VA 2 COMBINATION COVERING FOR 800 F, * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 P. Ambient Air Temperature inner Layer Thickness Inches 2*6 13& 2H me 2*6 v% 1*56 1% 1*6 1*6 1*6 1*6 *1*6 1*6 1*6 1*6 1% *1% m VA VA VA Outer Layer Thickness Inches None None None None None 1% 1% 2*! 2*6 3*6 VA 2*f 2% 3% 1% 2^ 2% 3H 1% 2^ 2**6 1% 1% 2% 2**6 3H Temp. F. at Inner Magnesia Surface 391 438 473 505 522 458 497 524 542 474 511 537 560 489 526 562 435 502 547 572 588 Canvas Temp. #F, with Air at 80 F. 129 134 133 141 133 130 121 114 110 105 125 117 113 108 126 119 114 109 129 122 114 124 131 123 117 113 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 125 1,180 143 1,460 154 1,820 182 2,270 176 2,580 171 3,200 154 3,200 139 3,200 136 3,200 119 3,200 183 4,640 171 4,640 157 4,640 147 4,640 222 5,920 198 5,920 180 5,920 165 5,920 254 7,260 228 7,260 198 7.260 234 7,260 289 8,600 246 8,600 223 8,600 208 8,600 Percent Eff. % 89.4 90.2 91.5 92.0 93.2 94.6 95.2 95.6 95.7 96.3 96.0 96.3 96.6 96.8 96.2 96.6 96.9 97.2 96.5 96.8 97.2 96.7 96.6 97.1 97.4 97.5 PERFORMANCE DATA: HEAT INSULATION F0R TEMPERATURES TO 600'F. BULLETIN No.104-A THE PHILIP CAREY MFG. COMPANY GENERAL OFFICES: IOCKIANO. CINCINNATI IS. OHIO 2-4 INS T04-A-900 FOREWORD 85% Magnesia, with an enviable performance record of over seventy years, stands alone today as the accepted standard of thermal insulation. Men charged with the responsibility of designing and operating the many types of equipment that make up our modern industrial processes specify 85% Magnesia. It is paramount to select a proven thermal insulation having the greatest re sistance to the flow of heat--thus obtaining the maximum in economv. Mechan ical properties adaptable to the particular problem must likewise be considered in balancing of savings against cost of insulation. Super-Light 85% Magnesia combines thermal and mechanical characteristics, is a superior product compared to the old style filter molded 85% Magnesia, and has light weight, high strength, low conductivity, great resistance to moisture, smooth finish, accurate fit. shock resistance and high dimensional stability--it will not crack due to internal shrinkage when applied on hot surfaces up to 600 'F. It effectively resists handling, shipping, impact and traffic; will not disintegrate, crack or crumble under normal service conditions, and may be removed for in spection of equipment and reapplied when necessary. It has excellent workability and high ductility. Carey Super-Light 85% Magnesia can be subjected to boiling water for hours without disintegration--a quality derived from its chemical "set*' monolithic structure. To assist in engineering calculations of problems in heat balance the data in this bulletin have been assembled. They will save much time. They reflect the care and accuracy of a specialized heat research laboratory, both as to performance of insulating materials and rates of loss from bare surfaces. Conductivity values used are averages from tests made at the Mellon Institute on numerous samples. The values for heat losses from uninsulated surfaces are those developed bv R. H. Heilman, Senior Fellow of The Mellon Institute, based upon his experimental work in this field as published in the paper "Surface Heat Transmission," Trans. Am. Soc. Mech. Engrs. Fuel Steam Power, 51, 275, (1929). Since this work repre sents the most exhaustive research in this field, the data developed are probably the most reliable and give a satisfactory basis for evaluating heat-insulation savings. Since Super-Light 85% Magnesia is so generally accepted a standard, a com plete set of thermal tables is given for this product. A set of BASE THERMAL TABLES to be used in combination with factors is given for other types of insu lating materials, making possible the development of similar data for such ma terials. The Philip Carey Mfg. Company offers the services of its engineering organiza tion and laboratories for assistance in individual engineering problems. 2.4 (NS 104-A.90) DESCRIPTIONS OF CAREY HEAT INSULATIONS CAREY 85% MAGNESIA For tempera lures up to 600 e F. Fur nished in semi-cylindrical pipe cov ering sections for pipe sizes up to 18 inch and in curved blocks for larger pipe sizes, also in flat blocks. A molded composition of Carbonate of Magnesia and Asbestos Fiber. In combustible, non-corrosive: crushing strength 60 lbs. per square incb: unaffected by water. Combines high efficiency with a very durable structure. Long-lasting--its insulating value improves with age. Structure is rigid but not brittle. Can be easily worked with ordinary carpenters' tools. Easily cut and formed to accom modate irregularities. The accepted quality standard for low, medium and high-pressure steam service where maximum per manent efficiency is desired. y CAREY AllTEMP Produced from a formulation of ex *- panded silica* and asbestos liber. Available in sectional, tri-sectional. .` .. ^ segmental and block forms. Alltemp ^ is recommended for insulating high * tempera lure piping and surfaces Mich as breaching, boiler walls, ovens, stills, and similar surfaces. It is an ideal insulator for irregular surfaces, due to its workability and ease of application. Its ex ceptionally low shrinkage factor, plus low co-efficient of con ductivity, assures outstanding, economical performance when used as a single material or in combination with Carey Super Light 85' c magnesia. Alltemp is water resistant, and offers an excellent surface for cements. Now accepted and being used by principal boiler manufacturers, engineering contractors, and industrv. ASBESTOS- SPONGE For temperatures up to TOO0 F. Fur nished in split cylindrical pipe cov ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. A resilient structure comprising ap proximately 30 to 40 layers of Asbestos Paper per incb of thick ness. The asbestos paper is processed with very small indenta tions, giving the finished product a spongy consistency, having very high insulating value. Asbestos-Sponge is specifically recommended for use on vibrating lines and for underground steam distribution lines because of its tough structure and because cylindrical pipe covering sections can be furnished for large pipe sizes. .....v-HT* CAREY OEFENDEX . ^ *'2;' ^ For temperatures up to 550 F. Fur r ^ L -3; lis? nished in semi-cylindrical pipe cov- J ."7* ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. *' . : / - T .- A semi-rigid structure comprising - ' - * ,'*'* 7 approximately 20 to 22 alternating ~ layers of flat and processed asbestos paper per inch of thickness. The processed asbestos paper contains innumerable very fine indentations which give proper spacing between succeeding layers. Defendex combines high efficiency, medium price and tough laminated asbestos struc ture. Recommended for low, medium and high-pressure steam service. MINERAL WOOL BLANKETS For temperatures up to 1200 0 F. Fur nished in flexible blankets 1 in. to 6 in. thick, 2 ft. wide bv 4 ft. or 8 ft. long consisting of mineral wool fibers felted to desired thickness and reinforced with wire mesh or metal lathe on both sides. These blankets combine the properties of high temperature resistance, high efficiency, low cost, flexibility and large-unit construction mini mizing cracks and joints. Recommended primarily for use in enclosed walls of ovens and similar equipment. CAREY A I R C E L L For temperatures up to 300 F. Fur nished in semi-cyiindricai pipe cov ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. A firm structure comprising alter nate layers of corrugated and flat asbestos paper firmly cemented to gether. Corrugations are H in. deep--4 plies per inch of thick ness. The lowest cost, incombustible asbestos insulation. Recom mended only for moderate temperature pipes and equipment where high efficiency and durability are not important. CAREY EXCEL For temperatures up to 300 F. Fur nished in semi-cylindrical pipe cov ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. A firm structure comprising alter nate layers of corrugated and flat asbestos paper firmly cemented to gether. Corrugations are 1, 6 in. deep--6 plies per inch of thick ness. Gives good efficiency and has more resistance to abuse and better appearance than Air Cell. Recommended for healing system piping and equipment. CAREY THERMOGLAS Thermoglas pipe covering is used on pipes having temperatures up to 350 F. It simply "snaps in place." Thermoglas is exceptionally light weight insulation and is composed of long, fine, blown glass fibers bonded with thermal-setting phenolic resin. It is a strong, semi-rigid and resilient insulation, with no coarse fibers to irritate hands or skin. Thermoglas is an excellent cold, dual-temperature insulation when used with a vapor barrier jacket. Vapor barrier for dual temperatures is furnished in black and white. Other types of jacketing are Foil Faced Flame Proof Kraft jacket or weatherproof jacketing at 35. 45, or 55 lb. weights. Also available with standard weight 4-oz., 6-oz. and 8-oz. canvas jackets. DESCRIPTIONS OF CAREY HEAT INSULATIONS * >. CAREY CAREYCEL For temperatures up to 300* F. Fur nished in semi-cylindrical pipe cov ing sections for pipe sizes up to T^. 16 in., also in Hat blocks and sheets. A firm structure comprising 12 to ^*~- - 14 layers of asbestos paper per inch thickness. The asbestos paper is processed with innumerable small indentations which space the lavers, prevent internal convection, reduce conduction by contact and create high efficiency. Incombustible, non-corrosive, rugged, low heat shrinkage and inexpensive. Its unusually low heal shrinkage makes it particularly desirable--minimizing unsightly cracks and conserving high efficiency. Recommended for beating systems and low' pressure process piping and equipment. No. 303 ASBESTOS CEMENT A general utility insulating cement. Furnished in 100-lb. bags. Com posed of a dry mixture of asbestos fibers and bonding clays. To use, it is mixed with water to a mortar consistency for application with a trowel. It adheres well to iron sur faces or to insulating materials, and trowels to a smooth finish. Covering capacity is approximated 18 sqi ft. 1 in. thick per 100 lbs. of dry cement. Recommended for pointing up joints in block insulation, for insulating small fittings in low-pressure systems and primarily for a smooth-fmisb coal over block insulation. CAREY PERFECTO For cold-water pipes to 53 s F. Fur nished only in semi-cylindrical pipe covering sections for pipe sizes up to 36 in. Not furnished in blocks or sheets. A semi-rigid structure com prising layers of indented organic insulating felt (sometimes termed ''wool fell*') firmly cemented together. Inner surface is lined with asphalt-saturated felt. Gives very high insulating value. Gives good results in preventing sweating and protecting from freezing. Recommended for service water piping carrying water down to 55* F. No. 707 ASBESTOS CEMENT For temperatures up to 500 F. Fur nished in 100-lb. bags. Composed of a dry mixture of asbestos fibers and bonding clays. To use. it is mixed with water to a mortar consistency for application with a trowel. It adheres well to iron or insulation surfaces, and trowels to a semi-smooth finish. Covering capacity is approximately 25 sq. ft. 1 in. thick per 100 lbs. of dry cement. Recommended for pointing up joints in block insulation, for insulating small fittings and for a finish coat over block insula tion where high efficiency rather than smooth finish is desired. CAREY IMPERVO For cold and ice water piping to 35 F. Furnished only in 3-foot long CAREY MW-50 CEMENT cylindrical pipe covering section*., For temperatures up to 1600* F. for pipe sizes up to 36'. Not fur Furnished in 50-lb. bags. Composed nished in block- or sheets. A semi of a dry mixture of springy pellets rigid structure comprising layers of of mineral wool, asbestos fiber and < insulating felt cemented together bonding clay. To use, it is mixed with asphalt saturated organic felts applied to both inner and with water and applied with a outer surfaces. Telescopic double layer construction recom trowel. Covering capacity is ap mended to provide staggered joint insulation and prevent air proximately 50 sq. ft. 1 in. thick per 100 lbs. of dry cement. infiltration. Gives verv high insulating value. Use for insulating Combines high insulating efficiency, toughness, reasonable hard chilled and ice water lines to keep water cold and prevent ness, excellent sticking properties and relative freedom from sweating. Proper sealing by use of a suitable vapor barrier is shrinkage cracks. Recommended as monolithic insulation for recommended to prevent infiltration of water vapor through the stills, tanks, furnace walls, etc. particularly where temperatures harrier into the insulation, causing condensation. of 600* F. or higher are encountered. CAREY PROTECTO Reduces the danger of freezing of exposed piping. Furnished only in 3-ft. long semi-cvlindrica) pipe cover ing sections, for pipe sizes up to 36'. Not furnished in blocks or sheets. A semi-rigid structure, consisting of an inner portion of cattle hair felt and an outer, reinforced structure of insulating felt (sometimes termed ''wool felt"). Furnished in and 2" thicknesses. Inner surfaces are lined with asphalt-saturated felt. Gives very high insulating value and i& especially designed for reducing danger of and delaying freezing time for unprotected water pipes. No insulation alone can prevent freezing, if the water stands still long enough. During extreme low temperature con- dilions, some water must be allowed to run during weekend or idle periods. CAREY MW-ONE CEMENT A one-coat, white finishing. Fur nished in 50-lb. bags. Composed of mineral wool pellets and other in* gredients. giving an all-purpose, fast setting, finishing cement that in sulates as well as protects. One-coat application, in the required thick ness, saves time, labor and money. Hydraulic setting takes place in two hours. MW'-One may be used directly over insula tion and as a finishing cement for MW-50. Covering capacity for MW-One cement is approximately 35 sq. ft., 1* thick, for 100 lbs. Can be furnished for temperatures up to 1800 F. (grey finish) and for use over non-ferrous materials in lots of 100 bags minimum. HEAT INSULATION FACTORS A complete set of performance tables for Super-Light 85 'c Magnesia Hill be found oo pages 905 to 909 inclusive. Performance values for other Carey beat insulation materials can be obtained by using the following table of factors which gi%e beat transmission relationships. These factors provide a quick and simple method of obtaining insulating values without the use of voluminous tables for each insulating material, and the per cent of error involved by their use is very small--generally less than the variation in heat transmission between different samples of the same material. The beat losses and efficiencies of the variou> Carev insulations can be determined by the use of these factors applied to the BASE THERMAL TABLES given on Pages 910 to 914 inclusive of this bulletin. TEMPERATURE DIFFERENCE, DEGREES FAHRENHEIT BETWEEN HEATED SURFACE AND AIR TYPE OF INSULATION Aircell..................................................................... Asbestos Sponge................................................. Carevcel............................................ .................... Carocel........... ....................................................... Defendex............................................................... Excel....................................................................... AlUemp................................................................. Thermoglas ......................................................... Hi-Temp No. 19............................................... Impervo ............................................................ Mineral Wool Blanket...................................... Perfecto................................................................. Protecto. ............................................................... 303 Asbestos Cement........................................ 707 Asbestos Cement...................................... MW-50 Cement.................................................. MW-One Cement. . -...................................... 100 1.400 1.050 1.090 1.400 1.143 1.360 1.228 .7^2 1.475 0.936 0.718 0.919 0.840 3.72 2.362 1.547 1.622 200 1.444 1.048 1.110 1.410 1.171 1.376 1.205 .712 1.408 0.949 0.746 0.907 0.812 3.49 2.295 1.499 1.552 300 1.488 1.045 1.130 1.420 1.199 1.392 1.182 .702 1.340 0.773 3.26 O *><>g 1.451 1.482 400 1.043 1 22? 1.159 .692 1.273 0.801 2.161 1.403 1.412 500 1.040 1.255 1.136 1.205 0.828 2.004 1.355 1.342 600 1.113 1.138 0.856 2.027 1.307 1.272 To find UNIT HEAT LOSS fB. T. L". per square fool per ;F. temperature difference between iron and air per hour1 multiplv the unit loss for corresponding conditions in the BASE THERMAL TABLES bv the heat insulation factor of the insulatinn for which this information is wanted. Example: What is the unit heat loss (B. T. U. per square foot per 0 F. temperature difference between iron and surrounding air per hour) for Carocel Covering 1' thick, for 3' pipe at 200 F. temperature difference between pipe and the surrounding air (steam in pipe at 270 F. and air temperature of room 70 F.)? Heat insulation factor for Carocel at 200 F. temperature difference from table U 1.410. Unit heat loss from BASE THERMAL TABLES for 1 * thickness for 3' pipe at 200 F. temperature difference between pipe and surrounding air is 0.419 from table on page 910. 0.419 x 1.410 -- 0.590 B. T. U. per square foot per degree F. temperature difference between pipe and air per hour. To find the EFFICIENCY of a Carey insulation listed in the table of factors, first find from BASE THER MAL TABLES the efficiency of the corresponding Covering for the conditions in volved--subtract this from 100--multiply the difference by the beat insulation factor--subtract this product from 100. Example*. What is the efficiency of Carey Carocel Covering 1' thick for 3' pipe at 200 F. temperature difference between pipe and the surrounding air? Heat insulation factor for Carocel at 200 F. temperature difference from table is 1.410. Efficiency of 1' thick Ol X 4* II BAS ETHER M A L TABLE Covering for same conditions is 84.9r7 from page 9J0. 100--84.9 = 15.1. * 21.29. 100--21.29 == 78.71fc efficiency desired. To find the SAVINGS in B. T. U. per lineal fool per hour for a Carey insulation shown in the table, first determine its effi ciency as indicated above, multiply this efficiency by the cor responding saving for BASE THERMAL TABLE Covering under the same conditions of pipe size, temperature and thick ness, and divide by the efficiency of BASE THERMAL TABLE Covering for these same conditions. Example: What are the savings in B. T. U. per lineal loot of pipe per hour for Carey Carocel Covering 1 * thick for 3' pipe at 200 F. temperature difference between pipe and surrounding air? Heat insulation factor for Carocel at 200 F. from table is 1-410. Tbe efficiency of Carocel under these conditions is 78.71 Cc (see previous example). Efficiency of BASE THERMAL TABLE Covering under these conditions is 84.9^ from the table on page 910. Savings by BASE THERMAL TABLE Covering under same conditions are 431 B. T. U. per lineal foot per hour from table on page 910. T8 ~1 431 x ^ ^ -- 398 B. T. L". per lineal foot per hour, savings required. HEAT INSULATION DATA CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 1 lA" Thick EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Savings of* in B. T. U. p*f lin*or foot of pip* p*f hour. Unit hint or* m B. T. U. par squor* foot of pip* surface p*r hour p*r "F. temperature difference between pipe ond surrounding oir. Pipe Size TEMPERATURE DIFFERENCE *F. KTWEB4 PIPE ANO SURROUNDING AIR ISO 350 400 : 1 Efficiency------ }/* ' ! Savings ............... j Unit Lots............. 3/g 7' ; 1 Efficiency......... | Savings ................. i Unit Lou .......... j 'Efficiency......... i Savings . | Unit Loss............... iy*" 'Efficiency......... Savings ................. Unit Loss ............. Vh" 1 Efficiency......... Savings.................... Unit Loss ... . i" 1, Efficiency.. . Savings .............. Unit Lots ... . ,, ! 1; Effiey......... 2/2 Savings ............... j Unit Loes ............. ' i Efficiency......... 3" Savings.................. Unit Lots............... 3V2" 1 Efficiency......... Savings ................. Unit Lou............... 4" ', Efficiency... Savings ................. Unit Loss . . 4/2" Efficiency......... Savings ............ Unit Loss . . . ` i Efficiency .... 5" Savings.................... Unit Loss ............. 1 Efficiency......... 6" Savings ............... Unit Loss ... . 7" 1 Efficiency... Savings.................... Unit Lou............... ` Efficiency......... 8" Savings.................... Unit Lou............... 1 Efficiency.......... 9" Savings.................... Unit Lou................ 10" 'Efficiency......... Savings ................. Unit Lou................ 12" 1 Efficiency......... Savings .................. Unit Lou................ 14" 1 Efficiency.......... Savings.................... Unit Lou................ 16" 1 Efficiency......... Savings.................... Unit Lou................ 1 O" 1O ! 1' ERwieacy......... Savings.................... | Unit Loes................ Flat 1 Efficiency.......... 79 6i 43 .505 50 si S4 466 83 If; 68 403 84 61 86 .360 84 61 97 . 355 85 91 121 320 85 11 143 333 87 O'-, 175 286 85 61 195 314 87 61 223 268 86 01 241 299 87 91 272 258 87 91 320 .253 88 31 366 .243 88 41 411 .238 88 51 456 .235 89 01 508 .224 88.91 596 .222 88.61 648 .227 88.71 735 .224 88.81 821 .222 90.41 194 .205 81.41 75 521 82.71 113 .537 S3 81 157 553 84 81 1 85.61 209 1 268 .569 1 .585 j 86 61 340 .600 i 87 31 420 616 88 01 511 632 88 8' 6IS 648 82 41 93 481 83 71 140 495 84.81 196 .510 85 71 i 86.SI i 87.41 260 1 333 423 .525 1 .540 | .554 88 11 S22 ; 569 88 81 89 4". 636 1 764 584 598 84 51 117 .416 85 61 176 429 86 61 245 .442 87 41 326 455 88 11 ; 88 91 1 89.61 j 90 2', 418 | 530 1 654 ! 797 ; 468 480 I 493 | 506 : 90 7', 957 S19 85 81 147 371 87.01 222 382 87.81 309 .394 88 61 411 405 89 31 527 .416 90 01 668 427 90 61 j 91 11 j 91 61 825 1005 1208 438 j 450 | 46) 86 01 167 366 87 01 251 377 87.91 350 .389 88 61 465 400 89 31 596 411 90 01 757 422 90 61 91 21 936 ; 1140 433 I 445 91 V . 1371 4S6 87 11 208 330 88 n 312 340 88 91 426 .350 89 61 579 360 90 21 743 371 90 9'; 943 381 91 41 j 91 91 1166 1421 391 .401 92 4' , 1709 411 86 41 246 344 87 41 370 354 88.31 516 365 89 01 687 .376 89.61 . 883 .387 90 41 1123 .397 90 9'; 1389 408 91 5', 1695 419 92 0' . 2041 429 88 n 301 295 89 01 452 304 89 81 630 314 90.41 838 323 91 01 1077 .332 91.61 1369 .341 92 21 1694 3S0 92 6', 2066 360 93 O' , 2487 369 86 81 336 324 87 81 504 335 88.61 70S 345 89 41 939 .356 90.01 1207 366 90 71 1537 376 91 31 1904 .387 91 8'. 2325 397 92 31 2802 408 88 61 382 277 89.51 574 285 90 21 801 294 90.81 1065 302 91 41 1370 311 92 11 1744 319 92.51 2159 328 93 01 2636 336 93 41 3175 34S 87 21 415 309 88 21 624 319 89 01 872 329 9 71 1162 .339 90 31 1405 .349 91 01 1905 358 91 61 2362 368 92 11 2885 378 92 6', 34 79 386 88 91 467 266 89 71 701 275 90 51 979 283 91 11 1303 292 91 6<; 1677 300 92 21 2135 308 92 71 2644 .317 93 21 3230 32S 93 6' , 3893 334 89 01 549 261 89 81 82S 270 90 $1 1154 278 91 21 1537 286 91 71 1978 29S 92.31 2S20 .303 92 81 3125 311 93 21 3818 319 93 6' , 4604 .328 89 31 . 628 251 90 11 94$ 259 90 81 1 91 41 1320 I 1760 267 275 92 01 2266 283 92 61 2887 291 93 01 3S81 .299 >3 S'; 4377 307 93 9', 5289 315 89 41 706 246 90 21 j 90 91 1061 1 1484 91.51 1979 254 | 262 1 .270 92.11 2548 .278 92.71 3250 .285 93 if; 4032 .293 93 6', <930 .301 93 9' ; 594 7 309 89 51 782 . 243 90 31 1177 .250 91 01 | 91 61 1647 1 2196 2S8 i 266 92 11 2829 .274 92 51 3599 .281 93.21 4476 .289 93 61 5478 .297 94 01 6614 .304 89 91 [ 90 71 872 1311 .231 .239 91 41 | 92.01 1834 | 2446 246 1 .253 89 91 1022 .229 90 71 ! 91 41 1538 | 2154 .237 1 .244 91 9% 2874 .252 92 51 31S2 .261 92.51 3706 .259 93 01 4021 .268 93.01 4731 .266 93.51 4993 .275 93 51 5875 .274 93 91 6108 .282 94 31 7372 .290 93 91 | 94 21 7192 8684 .281 289 89 61 1112 .235 90 41 1674 .242 91 11 2346 250 91.71 3132 .257 92.21 4039 .265 92.81 5159 .273 93.31 6412 .280 93 71 7850 288 94 11 9486 .295 89.61 1261 232 90.51 1899 239 91.11 2661 .247 91.81 3556 .254 92.31 4588 .262 92.91 5863 .269 93.31 7289 .277 93 8 1 8931 .284 94 r; 10792 . 292 89 71 1410 229 90 SI 2124 .237 91.21 2979 .244 91.81 3981 .252 92 31 5136 . 2S9 92 91 6570 .266 93 41 8)70 .274 93 81 10014 .281 94 2': 12105 289 91 21 332 .212 91 91 497 .219 92.51 692 .226 92.91 920 .233 93 41 1181 240 93.81 1501 .246 94 2 1 1857 253 94 61 ! 2265 1 .260 94 91 2726 267 All data from Motion Inttitute, Univonity oi Pittsburgh tests. HEAT INSULATION FACTORS To find CANVAS TEMPERATL RES lor any insulation, inuliiplv the unit loss for corresponding conditions in the Base Thermal Tables by the heat insulation factor of the insulation for which the canvas temperature is wanted. Then find the outer diameter of the insulation by adding twice the thickness of the insulation to the pipe diameter. Multiply the new unit loss by the temperature difference between the pipe anil the air. and by the ratio of the inner to the outer diameter of the covering to obtain the BTL loss per sq. ft. of canvas. From Figure "Surface Losses for Various Outside Diameters" find the temperature difference between the canvas surface and the air corresponding to the BTL' loss per sq. ft. of canvas and the Outside diameter of the covering. Add 80c F to this value to obtain the canvas temperatures for 80 F surrounding air. Example: What is the canvas temperature for Asbestos Sponge Covering 2 ' thick, for 3-in. pipe at 400 F tem perature difference between the pipe and the surround ing air? Heat Insulation factor for Asbestos Sponge at 400 F temperature difference from table is 1.043. Unit beat loss from "Base Thermal Tables" for 2' thickness for 3-in. pipe at 400 F temperature difference between pipe and surrounding air is 0.313 from table bn page 912. 0.313 x 1.043 = 0.326 BTU per square foot per F temperature difference between pipe and air per hour. The outer diameter of a 3*in. pipe is 3.5'. Twice the thickness of the insulation is 4*. The outer diameter of the insulation is therefore 3.5 x 4 or 7.5'. 0.32o x 400 x 3* -- -- 60.9 BTL' per square foot of canvas surface per hour. From the bottom of page 8. Bulletin 102-A. for a heat loss of 60.9 BTU follow the vertical line until it intersects the 7.5* line ^interpolated between the 6' and the 8' lines:, then follow horizontally to the left to where this line intersects the 37 F temperature difference line. Add 80 F to 37 F temperature dif ference to obtain 117 F. the canvas temperature for 80 F air. HEAT INSULATION DATA CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 1" Thick EFFICIENCIES, MEAT SAVINGS AND UNIT HEAT LOSSES Sovingt are in 6. T. U. per lineor foot of pipe per hour. Unit lots** ere in B. T. U. per square foot of pipe surface per hour per UF. temperature difference between pipe and surrounding air. Pipe Size tlMMUATUM DWCtCNCE f. UTWttN tlM AMD SUKKOUNOING AIK 100 150 900 250 300 450 ! 400 ' 450 500 550 W' Efficiency Saving* . Unit Loe* . . . 75 27c i 77 3% . 78 9*7 j 80.3*7 814% j 82 4*7 83 5*7 ! 84 5*7 1 85.3*7 j 86 1*7 41 i 71 : 108 | 151 i 201 ! 258 , 328 406 | 49S 596 614 ! 634 654 i .674 ; 694 .715 : 735 I 755 I .775 I .795 , T Efficiency ... ' 76 0*7 : 78 0*7 79 5*7 i 80 8*7 ! Saving*................. 1 51 | 88 : 133 I 186 . Unit Low .| 584 ! .604 1 .623 [ 643 --------------- ------------------------------------------ --^ . *7 Efficiency . 79 6*7 81 3*7 ..i. 82 6*7 1 83 8*7 1" Savings . 65 1 113 170 j 237 : Unit Lom .: 487 ! 503 ' .S19 1 .535 82.0*7 j 83 0*7 . 84 0*7 84 9*7 85 8*7 , 86 S', 248 i 320 ; 407 j S03 614 ; 740 .662 .682 I .702 | .721 ; .741 j .760 : - ! ` . 84 7* ; 316 .551 8S 6*; , 86 5% 87 3% 406 ' 516 j 638 .567 i 583 ! 599 88 0% 778 615 88 7% 936 .631 _f/ ,, : % Efficiency ------ \ 78.9*7 1 Va ; Saving* ............ 1 80 [ Unit Lots . 494 80.6*7 1 139 .511 i 82.0*7 1 83 2*7 209 | S28 j 293 544 84.2% 390 561 BS 1*7 502 .578 86 1*7 ' 86 9% I 87 6% 639 1 792 966 .595 [ .612 j 628 88 3% 1164 . 645 - i / ! r< Efficiency . 1 !/2 Saving* ; 81 0*7 | 93 . | Unit Lom................: 440 82.5*7 160 455 83 8*7 242 470 84 9*7 338 485 8S 7*; 450 .500 86 6% 578 .515 87.5% 736 .529 88 2% 911 -14 88 9% 1112 .559 89 5% 1338 .574 j *7 Efficiency..........j 82.2*7 83 7*7 84.9% 85 9*7 86 8*7 87.5% 88 4% 89 1% 89 7% 90 3% 2 1 Saving* ............... 116 200 301 421 561 721 918 1136 1387 1670 , Unit Lom............. ! .404 .418 431 445 458 472 485 499 .512 . S26 ,, ,, i *7 Efficiency . i 82 8*7 2V2 i Saving* ............... ! Unit Lom ... 139 .384 , *7 Efficiency . ! 3 I Stviagi..................1 [ Unit Loss | ^,.,,,1 *7 Efficiency........... j 31/2 Saving*...................... j | Unit Lom............. ! 83.0*7 16? .373 85 6*7 195 .314 84.3*7 240 .397 84.5*7 288 .386 86.6*7 335 324 8S 4% 361 410 85 6% 435 .398 87 2% 477 335 86 4% SOS 423 86 6% 608 .411 88.6% 70S .345 87 2*7 673 436 87 5% 811 .423 89 4% 939 .356 88 0% 866 449 88 2% 1044 436 90 0% 1207 .366 88 8% 1130 461 89 0% 1329 .449 90 7% 1537 .376 89 5% 1367 474 89 7% 1648 461 91 3% 1904 .387 90 1% 1669 487 90 3% 2014 .474 91 8% 2325 .397 90 7% 2011 SOO 98 8% 2428 486 92 3% 2019 .408 ; *7 Efficiency......... 84 0*7 85.3*7 86 4% 87.3*7 88 2*7 88 9% 89.7% 90 3% 90 9% 91 4% 4 1 Saving*.................... 214 368 554 775 1034 1332 1698 2016 2575 3106 Unit Lom................ .346 .358 .369 .381 .393 .405 .416 .428 440 . 451 4V4" *7 Efficiency......... Saving* .................. Unit Lom................ 86.0*7 241 .299 87.2% 415 .309 88 2% 624 .319 89.0% 872 .329 89.7% 1162 .339 90.3% 1495 .349 91 0% 1905 .358 91 6% 2362 .368 92.1% 2885 .378 92 6% 3479 .388 5" a." O 7 Efficiency......... Savings.................... Unit Lom................ i eieaey......... Savings.................... Unit Lom................ 84.0*7 260 .340 83 9*7 305 .338 85.4% 446 .352 85 3% 526 .350 86 5% 675 363 86.4% 793 .361 87 4% 945 .375 87 3% mi .373 88 2% 1262 .386 88.1% 1486 .385 88.9% 1627 .398 88.8% 1916 .397 89.7% 2075 .410 89.6% 2447 .408 90.3% 2576 .421 90.3% 3040 .420 90 9% 31S2 433 90 9% 3720 .432 91 5% 3805 .444 91.4% 4494 .443 Flat 1 % Efficiency......... > 86 4*7 v--|8KlL.Ilf 87.6*7 318 .301 88.5*7 1 89 3% 1 476 ' 668 i 312 ! .322 89 9% 890 .332 90.5% 1145 .343 91.2% 1458 .353 91.7% i 92.2% 1808 2208 .363 | .373 92 6% 2661 .384 All date from Mellon Institute, University o( Pittsburgh tests. 2-4 INS 104.A O05 HEAT INSULATION DATA CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 2" Thick EFFICIENCIES, MEAT SAVINGS AND UNIT HEAT LOSSES Sovmq! or* in 8. T. U. p*r linear foot of pipe per hour. Unit lorn* ore in B. T. U. per square foot of pipe surface per hour per aF. temperature difference between pipe and surrounding air. TIMFERATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNDING AIR Size ; . too i 150 200 250 900 350 400 490 ! % Efficiency . . . W Savings.................... j 1 Unit Lon . . ! 81 8% 45 .451 ' 83 4*7 77 : .465 84.6*7 115 478 ! % Efficiency... . . 83.2; : 84.6% 85.8*7 %" ! Savings ................. 56 96 144 1 Unit Loes........... 408 421 ' .433 , % Efficiency . . ! 85.2'"t | 86 s*; I" Savings ................. , 70 ; 120 { Unit Loss . . . ; 352 : 363 87 5*7 180 .374 1 % Efficiency . . . 85.8% VA" I Unit Loes................ j .331 i 87.1*7 ! 341 88 0*7 .352 1 % Efficiency . . ' 87 7% V/f ; Savings ............ . 101 : Unit Loos ............. j .285 1 % Efficiency.. . . : 88 o% 2" Unit Loo*............. j .272 1 88 7*7 ' 172 i .294 89 ir; 1 .280 89 6*7 258 303 89.9*7 289 2W % Efficiency... . : 89.3% Savings . . ! 150 Unit Loes . . 1 .239 90 2*7 257 .247 91.0*7 385 254 % Efficiency.. 1 89 0*7 3" Savings ............ 179 ! Unit Loos ............ .241 90 o*> 307 .249 90.8*7 461 .256 ZW % Efficiency . . Savings ....... Unit Loss . . 90.0% I 205 1 .217 90 9*7 351 .224 91 6*7 526 230 4" % Efficiency . Saving* . . Unit Loss 89 7 % 228 223 90 6*7 390 230 91 3*; 585 237 AW % Efficiency.. . Savings Unit Loss . 89.0*7 250 .236 89 9*7 427 .244 90 7*7 641 .251 % Efficiency.. . 90.0*7 90.8*7 91 6*7 5" Savings.................... 278 477 715 Unit Loss . . . .213 220 .226 % Efficiency.. . 90.2*7 91.1*7 91 8*7 6" Savings............... 328 562 843 .205 .21! .218 7" Savings . ... Unit Loes ... 375 .199 91 3*7 642 . 90S 963 212 % Efficiency......... 90.6*7 91.4*7 92 1*7 8" Saving*.................... 421 721 1083 Unit Loss............. .194 200 206 % Efficiency.......... 91.1*7 91.9*7 92 5*7 9" Savings ................. 469 803 1206 Unit Loes............... .182 .188 193 10" %f Efficiency.......... Savings .................. Unit Loss................ 91.0*7 520 183 91.8*7 889 .189 92 4*7 1336 ' .194 12" % Efficiency.. . Savings ................. Unit Loes................ 91.2% 611 .176 92.0*7 1046 .182 92.6*7 1572 .187 14" % Efficiency.......... Savings.................... Unit Loss............... 90.9% 664 .182 91.7*7 1138 .188 92 3*7 1709 .194 16" 18" Flat Vertical 2"TVk. % Efficiency......... Savings.................... Unit Loss............... % Efficiency.......... Savings .................. Unit Loos................ % Efficiency.......... Savings .................. Unit Loss............... 91.0*7 754 .179 91 0*7 842 .177 92.6*7 199 .159 91.7*7 1291 . 18S 91.8*7 1443 . 183 93.2*7 339 .164 92 4*7 1940 .190 92 4*7 2171 . 188 93.7*7 507 .169 8S 6*7 161 492 86.7*7 200 446 88 3*7 2S0 .385 88 8*7 .362 90 3*7 359 311 90 6*7 297 91.6*7 S36 262 91 4*7 642 264 92 2*7 733 .237 91 9*7 816 244 91 3*7 895 . 2S9 92.2*7 997 .233 92 4*7 1177 224 1345 218 92 6*7 1512 213 93 1*7 1684 199 93 0*7 1866 200 93 2*7 2196 . 193 92 9*7 2392 199 93 0*7 2714 .196 93.0*7 3038 . 194 94.2*7 705 .174 86.5*7 213 .506 87.5*7 265 459 89.0*7 332 .396 89.5*7 .372 90 9*7 477 .320 91.2*7 589 306 92.1*7 711 269 92 0*7 853 .271 92 7*7 974 244 92 4*7 1084 251 91 9*7 1190 266 92 7*7 1326 240 92 9*7 1566 231 93 0*7 1791 224 93 1*7 2013 .219 93.5*7 2242 . 20S 93.5*7 2486 206 93 7*7 2928 .198 93 4*7 3190 .205 93.5*7 3622 .202 93.5*7 4056 . 199 94.6% 936 .179 87.2*7 273 520 88.2*7 340 472 89.7*7 425 .407 90 1*7 532 .383 91 4*7 611 .329 91 7*7 755 314 92 6*; 912 .277 92 4*7 1094 .279 93 1*7 1249 251 92 9*7 1392 258 92 4*7 1529 274 93 17 1704 247 93 37 2013 237 93 4*7 2302 231 93 67 2590 .225 93 9*7 2885 211 93 9 7 3200 .212 94.1% 3770 .204 93.8% 4109 .211 93.9% 4667 .208 93.9% 5227 .205 94.9% 1201 .185 88.17 346 .533 89 0*7 431 484 90 4% 539 418 90.8% 674 ` .393 92 0% 774 .338 92.3% 958 .322 93.1% 1157 .284 93 0% 1389 287 93 6% 1587 257 93 4% 1769 265 93 0*7 1945 .281 93 6% 2167 .253 93.8% 2561 .243 93 9% 29.iO 237 94 1% 3298 .2-1 94 4% 3674 .216 94 3% 4078 .217 94.5% 4807 .209 94.3% 5241 .217 94 3% 5957 .213 94 4% 6674 .211 95.2% 1524 . 190 88 7% 427 . 547 89 6*7 531 497 90 97 664 429 91.3% 832 403 92 5% 955 .347 92.7% 1183 .331 93.5% 1429 292 93 4% 1717 294 94 0*7 1962 .264 93 8*7 2189 272 93 4% 2408 289 94 0*7 2682 260 94 2% 3173 . 250 94 3% 3631 .243 94 4% 4089 .237 94 8% 4555 222 94 7% 50S9 .223 94 9% 5963 .215 94 6% 6506 .223 94.7% 7399 .219 94 8% 8193 .216 95 5% 1883 .195 All dare from Mellon Institute, University of Pittsburgh tests. 500 89 47 519 561 90 2% 646 510 91 4': 808 440 91 9*7 10*3 .413 92 97 1162 35S 93 2*7 1441 339 93 9*7 1740 .299 93 8% 2093 .302 94 4% 2391 271 94 2*7 2669 279 93 8% 2939 296 94 4% 3272 .267 94.6% 3873 .256 94.7% 4435 .249 94 8% 499S .244 95 1% 5565 .228 95 0% 6192 229 95 2% 7294 .220 95 0% 7960 .228 95.1% 9054 225 95 1% 10153 .222 95 8% 2295 .200 550 90.0% 623 S74 90 8*; 77S 522 91 9% 970 451 92 3% 1217 424 93 3% 1396 364 93 6*; 1731 .348 94 3% 2091 307 94 2% 2517 309 94 7% 2877 277 94 5*7 3213 286 94 2% 3539 304 94.77 3942 .273 94 9*7 4666 263 95.0% S345 . 2S6 95.1% 6021 .250 9S.4% 6712 .233 95 4% 74S8 .234 95.5% 8789 .226 95.3% 9609 .234 95 4% 10935 .230 9S 4% 12266 .227 96 1% 2760 .205 HEAT INSULATION DATA CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 2W Thick EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Saving* art in B. T. U. ptr linear feet of pip# ptr hour. UnH lossy art in B. T. U- ptr square feet ef pipe surface per hour per F. temperature difference between pipe and surrounding air. Pipe Size : 100 TEMFEIATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNDING AIR ISO 200 ] 250 300 350 400 450 w '( Efficiency. Savings . . Unit Loss . O Efficiency. Savings Unit Lees ' r Efficiency. Sevings . . . Unit Lou 1 Va O Efficiency. Sevings . . . Unit Lou . c'r Efficiency. V/i" ! Sevings . . . Unit Lou . . O Efficiency. 2" Sevings. ... Unit Lou. . . 2'/a' O Efficiency. Sevings Unit Lou . . a1/*' O Efficiency. Sevings Unit Lou . cc Efficiency. Sevings . . . Unit Lou. . 0 Efficiency. Sevings . . . Unit Lou . 4%' 0 Efficiency. Sevings Unit Lost . O Efficiency Sevings Unit Lou . . . `7 Efficiency Sevings . Unit Lou . . 0 Efficiency. Sevings........... Unit Lou. . . 97 Efficiency. Sevings. . . Unit Lots . 97 Efficiency. Sevings .... Unit Lott.. . 10' 9c Efficiency. Sevings.......... Unit Lots. . . 12' 97 Efficiency. Sevings........... Unit Lou. . . 14' 97 Efficiency. Sevings........... Unit Lou.. . 16' <7 Efficiency. Sevings.......... Unit Lou . . . 18" 97 Efficiency. Sevings........... Unit Lou. . Fiat Vertical 2 Tb'k. 97 Efficiency. Sevings ... Unit Lou . . . : 82 7'7 84 20 1 45 . 78 . 428 441 85 4 <7 i 86 60 i 57 : os 1 .356 367 ' 86 60 . 87 80 1 71 , .319 122 329 87. *'7 ; 89 [ 294 88 5'; 152 303 88.8r7 102 259 89 80 174 267 i 89 3*7 ! 126 , 243 90 20 216 .250 89.30 150 .239 90.20 257 .246 90 4*7 182 .211 91 497 312 218 91.297 208 192 92 OO 355 .198 91 0O 232 194 91 897 396 200 91.70 257 .177 92 40 439 183 91 4-7 283 .183 92 IO 483 189 91.60 333 176 92 40 S70 181 j 92.30 430 .158 92 40 476 155 92.397 527 156 92 60 620 . 149 92.397 675 .153 92 4 97 766 . 150 92.50 856 . 148 93.997 201 . 130 92 90 726 163 93 IO 814 . 160 93 OO 901 161 93 20 1060 .154 93 097 1154 .158 93 197 1309 155 93 IO 1464 .153 94 SO 343 .134 85 4 0 : 86.40 r. 87 20 117 ' 162 ` 215 454 466 479 87.697 147 .377 88 40 204 .388 89 20 270 398 88 70 182 339 89 40 253 .348 90 IO 336 .357 89 4'7 228 312 90.10 317 .321 90.70 420 330 90 50 261 . 275 91 20 363 282 91 80 481 290 90 9 0 323 258 91 60 449 .265 92.10 595 273 91 OO 385 .254 91 60 536 261 92 IO 711 269 91 90 466 .224 92 50 649 231 93 OO 862 .237 92 60 532 .204 93 IO 740 .210 93.50 983 .216 92 4 0 593 206 93 OO 825 212 93 40 1096 .218 93 00 658 . 188 93 SO 916 194 94 OO 1217 199 92 80 724 194 93 30 1009 200 93 70 1341 .205 92 90 8S4 187 93 50 1191 192 93 90 1S83 198 93 50 1100 168 93 70 1221 .164 93 50 13S2 166 93 80 1591 . 1S8 93.50 1732 .163 93 70 1966 .159 93 7% 2200 .157 94 9 0 513 138 94 0O 1534 173 94 10 1703 .169 94 00 1887 170 94 20 2221 .163 94 IO 2422 .167 94 IO 2748 164 94 20 3075 . 162 95.30 713 . 242 94 40 2041 .178 94 50 2266 174 94 40 2512 .175 94 60 2958 .168 94.50 3226 . 172 94 50 3663 . 169 94.60 4102 .166 95.60 946 .146 87 90 275 492 89.80 346 409 90.70 430 367 91.30 538 339 92 20 616 298 92.60 763 .280 92.60 912 .276 93 40 1105 .244 93 90 1260 222 93.80 1406 .224 94.30 1561 .205 94.10 1722 211 94 30 2034 203 94 80 2623 . 183 94 9 0 2913 .179 94 8 0 3231 . 180 95 OO 3806 .173 94.80 4152 .177 94.90 4717 .174 94 90 5283 .171 95.80 1212 151 88.70 349 . SOS 90 SO 438 420 91.30 544 .377 91 80 682 348 92 80 780 306 9310 967 .287 93 IO 1157 .283 93.80 1402 251 94 40 1599 .227 94 30 1786 230 94 70 1982 .210 94 50 2188 .217 94.70 2586 .208 95.20 3338 .187 95 30 3707 .183 95.20 4114 . 185 95.40 4849 .177 95.20 5292 .182 9S.30 6015 178 95.30 6740 .176 96.10 1538 .155 89 30 430 518 9100 539 430 91 80 671 .386 92 30 841 .357 93 20 962 314 93 SO 1193 .295 93 50 1429 .291 94 20 1732 .257 94 70 1976 233 94 60 2208 236 9510 2451 216 94 90 2707 .222 95 OO 3201 .214 95 50 4135 . 192 95 60 4594 .188 95 SO 5101 .190 95 70 6013 .182 95.50 6566 .187 95 60 7467 .183 95 6 0 8370 .180 96 40 1899 .159 All date from Mellon Institute, University of Pitttbvtih tests. 500 90 OO S22 530 91 SO 655 441 92 30 816 396 92 80 1023 366 93 6 0 1171 321 93 90 1452 302 93.90 1740 .298 94 602110 264 95.10 2408 239 95 OO. 2691 242 95 4 0 2988 .221 95 20 3301 .228 95 4 0 3905 219 9S 80 5048 .197 95 80 5610 .193 95.80 6232 .194 95 90 7344 .187 95. SO 8028 .191 95 90 9132 .188 95 90 10240 18S 96 6 0 2313 .163 550 90 627 543 92 OO 786 4S 1 92 7^ 979 40S 93 20 1228 375 94. OT UQS 329 94 30 1744 310 94 30 2091 306 94 90 2537 270 95 4 0 289$ .245 9S 30 3238 248 95 70 3595 227 9S 50 3974 233 95 60 4702 225 96.00 6080 202 96 IO 6762 197 96 IO 7513 .199 96 20 8864 . 191 96.10 9686 196 96 irr 11220 192 96.20 12365 . 189 96 80 2781 167 HEAT INSULATION DATA CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 3" Thick EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Sovings are in 8. T. U. per iineor foot of pipe per hour. Unit fosse* are in B. T. U. per square foot of pipe surface per hour per *F. temperature difference between pipe and surrounding air. Size . <00 TEMPERATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNDING AIR 150 200 250 , 300 ! 350 ; 400 450 500 550 ' Efficiency.. Unit Loss . . . 84 O'. i 85 4', ' 79 397 I 409 '. Efficiency Savings . Unit Loss . ' 86 3',' 1 87 5', 58 99 332 : 342 . ', Efficiency 87 6', 1 88 7', 1" Savings . . 72 123 ; Unit Loss . . . 296 305 . ' Efficiency 1%" Savings . . . Unit Loss .. 88 4', 90 270 89 5'; 154 278 1i * jS ', Efficiency . Savings . Unit Loss 89 6'. 90 S' , 103 j 176 240 : 247 2" ' ', Efficiency . Savings ; Unit Loss . 90 2' : 91 r, 127 ' 218 222 j 229, 2Y2" `. Efficiency . Savings . Unit Loss . : ' e Efficiency . . 3" i Savings ; Unit Loss . . 90 S', 91 3', 152 260 213 220 91 3'i 184 191 92 r. 314 197 1 1, Efficiency . . 3W' ; Savings . . Unit Loss 92 r; 210 173 92 8`; 358 178. 4" '. Efficiency ; Savings Unit Loss 92 O' . 234 173 92 7', 400 178 4V2" '. Efficiency Savings . Unit Loss 5" \ ' i Efficiency . \ Savings i Unit Loss . 92 S' . 259 160 92 4', 286 162 93 2'. 443 165 93 0'. 488 167 6" '. Efficiency Savings . Unit Loss . 92 6'. 337 155 93 3', S76 160 7" ', Efficiency Savings . Unit Loss . . . . 93 0', 386 146 93 6', 658 1S1 1, Efficiency.. . 93 r; 93 7' 8" Savings . . . 433 740 Unit Loss 142 146 9" ', Efficiency . . Savings . ... Unit Loss . ... 93 3'i 481 . 138 93 91 821 .142 10" `, Efficiency . 93 3r; Savings . 533 Unit Loss .1 136 93 91 910 .140 12" ', Efficiency . . i 93 4', Savings.................... : 626 Unit Lots............. .132 94 01 1069 .136 14" 1 Efficiency..........i Savings ................ Unit Loss........... 1 93 3S 682 .133 93 91 1166 .137 16" 1 Efficiency........... i Savings ................ 1 Unit Loss ... . 93 4-", 774 130 94 of; 1323 . 134 18" 1 Efficiency.. . i Savings.................... : Unit Loss................: 93.51 866 . 128 94.11 1480 . 132 Flat Vertical 3" Th'k. 1 Efficiency......... : Savings ............... Unit Loss........... 94 91 203 .110 95 31 346 .113 ; 86 4', ; ns : 421 i 88 4'. >48 352 ; 89 5'. 184 ; 3i4 1 90 2', ! 230 1 286 ' 9i 2-; 263 254 91 8', 325 235 92 O', 389 226 92 7', 470 203 93 3' 536 184 93 3'. 598 183 93 7', 663 170 93 6'. 731 172 93 8'; 861 165 94 11 986 . 155 94 2V 1108 151 94 31 1229 . 147 94 4'; 1364 . 144 94 s'; 1603 140 94 4i 1748 141 94 S'; 1984 138 94.51 2220 .136 95 7i 517 .117 , 87 3' , 1 164 ! 433 88 1', i 217 | 44S ! 89 2'; 206 362 89 91 272 372 ! 90 2', ' 256 ! .323 \ 90 9', ! 320 ! 294 90.81 339 .332 91 51 424 302 91 8'i 366 262 92 41 484 269 92 3',' : 4S2 242 92 81 600 248 92 5'; 541 233 93 01 718 239 93 21 6S4 208 93 7' , 868 214 93 8'; 746 189 94 21 989 194 93 7'i 832 189 94 2'. 1104 194 94 2', 923 174 94 61 1244 179 94 c; 1017 177 94 4' , 1351 182 94 3',' 94 6'. 1201 1595 . 169__ | 174 94 5f; 1374 160 94 91 1826 164 94 6i 1 S44 155 95 01 20S3 160 94 71 1714 . 1S1 95 11 2280 .155 94 81 1902 149 95 11 2531 153 94 91 2237 144 95 31 2978 148 94 81 2442 .145 95.21 32S1 .149 94 91 2771 . 142 95.31 3692 146 94 91 3101 . 140 95.31 4134 . 144 96 01 719 . 120 96.21 9S3 .124 , 88.7'', ! 278 | 458 I 90 51 i 348 j .382 | 91.31 1 433 ! .341 ! 92 01 543 .311 1 92 81 620 276 93 3' , 768 2S5 93 41 920 246 94 01 1113 220 94 51 1268 .200 94 SI 1417 199 94 91 1571 184 94 8'i 1734 187 95 01 2048 179 9S.21 2345 169 95.31 2638 164 95 41 2930 160 95 51 3254 . 1S7 95 51 3830 .153 95 51 4182 .154 95 61 4752 .150 95 61 5321 .148 96 51 1221 .127 ; 89 | 470 ! 91 11 1 441 | 392 91 91 548 349 92.51 687 319 93 31 785 283 93 71 969 262 93 91 1166 .252 94.51 1411 226 94 91 1609 205 94 9'; 1798 .204 9S 31 1993 189 95 21 2202 192 95 31 2602 .184 95.51 2980 .174 95 71 3355 168 95.81 3727 .164 95 81 4141 161 95 91 4876 .157 95.81 5327 .158 95 91 6056 . 154 96.01 6787 . 151 96 71 1548 .130 , 90 11 ! 482 91 6' , 543 402 92 4' , 675 3S8 93 O'. 84 7 327 93 71 968 .290 94 11 1201 268 94 3', 1440 .259 94.81 1743 232 9S 31 1987 210 95 31 2222 209 95 61 2464 194 95 51 2723 197 95-61 3220 189 9S 81 3690 .178 95 91 41S4 . 173 96.01 4617 . 168 96 r; 5132 .165 96 21 6044 .161 96 11 6607 .162 96 21 7514 . 158 96 21 8423 . 155 96 91 1910 .134 90 61 .494 1 92 11 : 659 ! 412 1 92 91 821 j 367 1 93 5', 1 1054 33S 94 r. 1176 298 94 51 1460 . 275 94 6`, 1753 265 95 11 2122 237 95 61 2421 21S 95.51 2707 . 21S 9S 9', 3003 . 198 95.81 3320 .202 95 91 3928 . 193 96 11 4501 .183 96 2'; 5070 . 177 96.31 5636 .172 96 31 6265 170 96 41 7385 16S 96 41 8074 .166 96 41 9186 162 96 51 10302 159 97 11 2326 .137 . 91 21 ! 631 [ .506 I 92 51 791 S 422 ! 93 31 | 984 1 .376 93 8` r 1236 343 94 4- , 1412 30S 94 8'i 17S4 281 94 91 2106 .272 95 4' , 2551 243 95 81 2909 .221 95 81 32S6 220 96 11 3612 203 96 0' r 3994 .207 96 2', 4727 198 96 41 5421 187 96.4'; 6105 . 182 96 51 6790 .177 96 61 7551 174 96 6` ; 8904 .169 96.61 9738 . 170 96 71 11008 . 166 96 71 12432 163 97 31 2795 .141 All dare (torn Mellon Institute, University of Pittsburgh rests HEAT INSULATION DATA BASE THERMAL TABLE 1" Thickness EFFICIENCIES, HEAT SAVINGS ANO UNIT HEAT LOSSES Savings ara in B. T. U. par linear foot of pip* par hour. Unit losses aro in B. T. U. par square foot of pipa surface par hour per F. temperature difference between pipa and surrounding air. Pipe Size j. TEMPERATURE DIFFERENCE *F. 8ETWEB4 PIPE AND SURROUNDING AIR too | ISO ! 200 1 250 ji 300 350 400 450 500 5S0 i % Effideney . . . ! Saving*................ | Unit Loo*........... W ' % Effideney ... Saving*................ Unit Loss............ 75.2% 1 76.7% 41 70 0.614 j 0.643 77.0% i 78.4% 51 J 87 0.558 0 584 78.3% 106 0.672 80.2% 136 0 610 79.4% 148 0.701 81.0% 187 0.637 80.5% 199 0.730 81.9% 249 0 663 81.5% 257 0.759 82.9% 322 0.689 82 4% 324 0.788 83.7% 405 0.716 83.2% 400 0.817 84.5% 501 0.742 84.0% 490 0.846 85.3% 614 0.768 8* 8% 5*0 0.875 86 0% 737 0,795 % Effideney . .. 78.5% 79.8% 81.2% 82.3% 83.2% 84.0% 84 8% 85.6% 86.3% 87.0% 1' Savings................ 64 109 167 233 311 401 505 625 766 921 Unit Loos............ 0.511 0.535 0 559 0.584 0.608 0.632 0.6S7 0.681 0.705 0.730 r U/<' % Effideney ... Saving*................ Unit Los*............ 79.9% 81 0.470 81.2% 138 0.492 82.5% 211 0.514 83.4% 294 0 537 84.3% 393 0.559 8S.1% 507 0.581 85.9% 640 0.604 86.6% 792 0.626 87.3% 968 0.648 87.9% 1165 0.671 1%' % Efficiency . . . Savings................ Unit Lots . . . 80.5% 93 0.4S0 81.7% 157 0.471 83.0% 240 0 493 83.9% 334 0.515 84.8% 446 0.536 85.6% 577 0.558 86.3% 727 0.S80 87.3% 924 0.601 87.7% 1102 0 623 88.3% 1327 0.64S 2" % Effideney . . . Savings................ Unit Lose ...... 81.5% 11S 0.421 82.5% 194 0 441 83 8% 297 0 462 84 6% 413 0.482 85.5% 5S4 0.502 86.3% 716 0.523 87.0% 905 0.543 87.7%. 1119 0.S63 88 3% 1371 0.583 83 9% 1651 0.604 2Vz' % Effideney ... Savings................ Unit Low............ 82.1% 138 0.399 83.1% 233 0 419 84 4% 357 0 438 85.3% 498 0 457 86.1% 665 0.477 86.8% 860 0.496 87.5% 1089 0.515 88.1% 1347 0.535 83.8% 1651 0.554 89 3% 1991 0.573 3' % Effideney . .. Saving*................ 82.6% 167 83.6% 282 84 9% 431 8S 7% 601 86. S% 804 87.2% 1041 87.9% 1316 88.5% 1629 89 2%, 1999 89 7% 2411 Unit Los*............ 0 382 0 401 0 419 0 438 0.456 0.475 0.493 0.512 0.530 0.549 3V4' 4' 4V2' % Effideney . . . Savings................ Unit Low............ % Effideney . . . Saving*................ Unit Los*............ % Effideney . . . Savings ......... .. Unit Los* .... 83 0% 189 0.371 83.2% 212 0.363 83.4% 234 0.355 84 0% 321 0 389 84 2% 359 0.381 84 4% 39S 0 372 85.1% 489 0.407 85.3% S47 0.399 85 6% 605 0.390 86 0% 682 0 425 86.2% 765 0 416 86 3% 843 0 407 <6.8% 913 0.443 87.0% 1024 0.434 <7.2% 1134 0.42S 87.5% 1183 0.461 87.7% 1324 0.452 87.9% 1466 0.442 88.2% 1496 0.479 88 3% 1674 0.470 88.5% 1855 0.460 88.8% 18S3 0.497 88.9% 2076 0.488 89.1% 2295 0 477 89 4% 2275 0.515 89.5% 2550 0.505 89.7% 2820 0 494 89.9% 2739 0.533 90.1% 3072 0.523 90.2% 3399 0.512 5" % Effideney . .. 83.5% 84 5% 8S. 7% 86 5% 87.3% 88.0% 88.7% 89 2% 89.9% 90.3% f Saving*................ Umc Lots............ 2S8 0.349 436 0 366 670 0 383 933 0 400 1257 0.417 1626 0.434 2058 0.4S1 2547 0 468 3131 0 485 377S 0.502 6" % Effideney . .. Saving*................ 83.9% 306 84.7% 514 86 0% 791 86 7% 1103 87.5% 1481 88 2% 1918 88.9% 2431 89 4% 3011 90.0% 3704 9C.5% <478 Unit Los*............ 0.339 0.3S6 0 372 0 389 0 406 0.423 0.439 0.4S6 0.473 0.490 7' % Effideney . . . Saving*................ 84.0% 3S0 84 9%' S88 86.1% 902 86 9% 1264 87 6% 1693 88.3% 2195 89 0% 2783 89.5% 3449 90.1% 4245 90.7% 5136 Unit Loss............ 0.332 0 349 U 365 0 382 0.398 0.415 0.431 0 448 0.465 0 481 8" % Effideney ... Savings................ 84.1% 392 85 0% 661 8`> 2% 1013 87.0% 1422 87.7% 1905 88.4% 2471 89.0% 3126 89.6% 3886 90.2%. 4775 90.7% 5779 Unit Loss............ 0.327 0 343 360 0 376 0.393 0.409 0.425 0.442 0 458 0.475 9' 10' ,2- % Effideney ... Saving*................ Unit Loo*............ % Effideney ... Savings................ Unit Loo*............ % Effideney . . . Savings................ Unit Loo*............ 84.2% 434 0.323 84.3% 482 0.319 84.3% S67 0.314 85.1% 731 0 339 85.2% 813 0.335 85.3% 958 0.330 8o.2%, 1123 0 356 86 3% 1245 0.351 86 4% 1467 0.346 87 0% 1577 0.372 87.1% 1749 0 367 87 2% 2056 0 361 87.8% 2115 0.388 87.9% 2347 0.383 88 0% 2762 0.377 88. S% 2745 0.404 88.6% 3048 0.399 88.6% 3590 0.393 89.1% 3474 0.420 89.2% 3859 0.415 89.3% 4576 0.409 89.7% 4321 0.437 89.8% 4803 0.431 89.9% 5667 0.424 90 3% 5311 0.453 90.4% 5906 0.447 90. S% 6972 0.440 90.8%, 6417 0 469 90.9% 7138 0.463 91.0% 8431 0.4S6 14' % Effideney .. . Saving*................ Unit Loos............ 84.3% 615 0.312 85.3% 1040 0.327 86 4% 1595 0 343 87.2% 2236 0.3S8 88.0% 3007 0.374 88.7% 3910 0.390 89.3% 4960 0.405 89.9% 6180 0.421 90.S% 7590 0.436 91.0% 9203 0.452 16' % Effideney . .. Savings................ Unit Loo*............ 84.3% 695 0.309 85.3% 1177 0.324 86.4% 1807 0 340 87.2% 2S37 0.355 88.0% 3413 0.371 88.7% 4443 0.386 89.4% 5638 0.401 89.9% 6991 0.417 90.5% 8636 0 432 91 0% 10475 0.448 18' Flat Vertical 1' Th'k % Effideney . .. Saving*................ Unit Low............ % Effideney ... Saving*................ Unit Low............ 84.4% 780 0.306 86.3% 184 0.292 85.3% 1322 0.321 87.3% 314 0.306 86.5% 2031 0.337 88.1% 476 0.320 87.2% 2840 0.3S2 88.8% 664 0.336 88.0% 3825 0.367 89.4% 88S 0.350 88.7% 4981 0.383 90.0% 1146 0.365 89 4% 6325 0.398 90.5% 1448 0.380 89.9% 7845 0 414 91.0% 1798 0.394 90.6% 9696 0.429 91.5% 2191 0.409 91.1% 11768 0.444 91.9% 2054 0 424 All dmte from Mellon Institute. University of Pittsburgh tests. HEAT INSULATION DATA BASE THERMAL TABLE IVa" Thickness EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Savings are in B. T. U. per linear feet ef pipe per hour. Unit losses ore in B. T. U. per square foot of pipe surface per hour per F. temperature difference between pipe end surrounding air. Pipe size * TEMPERATURE DIFFERENCE *F. BETWEEN PIPE AND SURROUNDING AIR 100 ISO 200 ; 2SO 300 350 400 4SO j 500 j 390 ; % Efficiency . . . \L" : Savings................ /z | Unit Los*............ 79.2% 43 0.515 80. S% 73 0 538 1 81.9% | 82.8% | 112 | 1SS 1 0.562 1 0 585 83 8% ! 84 6% 207 ; 267 0 609 | 0 632 t 85 3% 1 86 0% 336 1 414 0 656 ' 0.680 86.7% 506 0.703 87.4% 608 0.727 1 % Efficiency . . . %/." 1 Saving*................. '* j Unit Loss............ 81.0% 54 0.462 82.1% i 83 6% 1 84 3% 91 I 142 194 0.483 | 0.504 ! 0 S26 85 1% I 85 9% 258 ! 333 0 546 : 0 568 86 6% , 87.2%, 419 : 517 0.589 0.611 87.9% 632 0.632 88.5% 759 0.653 ! % Efficiency ... i 82.4% 1" Savings........... j 67 Unit Los*......... j 0.418 83.5% 1 84.7% j 85 6% 114 j 174 . 242 0 437 0 456 i 0 475 86 4% 1 87.0% ; 87.7% 323 I 415 1 523 0 494 | 0.513 | 0 532 | 88 3% 89.0%, ! 89 5% 64S j 789 : 948 0.5S1 0.S70 1 0.589 i % Efficiency . . . 83.8% 84 8% | 86 0% 86 7% 1 87 S% 88.1% 88.7% 1 89.3% 89 8% 90.3% 1 Savings................ 85 144 j 220 305 407 ! 524 661 1 816 997 1197 Unit Lots............ 0.378 0 396 ! 0 413 0 431 | 0 448 j 0 465 j 0 483 1 0.S01 0.518 0.536 1w % Efficiency . .. Savings ................ Unit Loss............ 84 5% 97 0.359 85.4% ! 164 | 0 375 86 5% 250 0 392 87 2% ! 87 9% ' 88.6% 1 89.2% : 89-9% 347 : 462 . 598 ' 751 1 9S2 0 409 ' 0 425 ' 0 442 1 0 4$8 1 0.47S 90.3% 1135 0 492 90.7% 136S 0.508 , % Efficiency ... I 85 4% ! 86 2% 1 87 3% \ Savings................ ; 121 | 203 1 3J0 UnitLoss... . 1 0 332 ! 0 347 j 0 362 88 0% , 88 7% 429 1 574 0 378 i 0.393 i 89 3% 740 0 409 89 9<7 1 90 4% 934 1 1153 0 424 ! 0.439 90.9% 1410 0 455 91 3% 1697 0.470 2W % Efficiency ... i Savings........... 1 UnitLoss........... | 86.1% 145 0.311 86.9% 243 0 326 i 87 9% i 88 5% 1 89.2% 1 89.8% i 90.3% j 90.8% ' 372 : 517 j 689 : 890 ' 1124 1 1388 0 340 : 0 35S 1 0 369 0.384 1 0.399 ; 0 413 91.3% 1699 0.428 91.8% 204S 0.442 % Efficiency ... 86.6% | 87 4% 88 4% : 89 !% ' 89 7% 90 2%- 90 8% 91.3% 91.7% 92.2% 3' Savings................ 175 29S j 449 625 834 1077 ; 1359 1679 2057 2477 UnitLoss............ { 0.294 ! 0 308 0 321 0 335 0 349 0 363 : 0 376 0.390 0.404 0.418 1 % Efficiency ... i 87.0% 31A* ! Saving*................ ! 199 /z | Unit Loss............ 1 0.283 87 8% ! 88 7% 89 3% 335 [ 509 : 709 0 297 I 0 310 : 0 323 90 0% . 90 5% 91 0% j 91.5% 947 1224 1544 1910 0 336 0 349 0.363 1 0.376 92.0% 2341 0.389 92.4% 2815 0.402 1 % Efficiency ... i 87.3% 4' ! Savings................ j 222 I Unit Los*............ ; 0.27S 88.1% 375 0 288 1 88 9 % S70 0 301 : 89 6% . 90 2% 795 i 1062 0 314 : 0 327 90 7% i 91 2% ' 91 7% 1370 1 1729 ! 2140 0 340 1 0 3S3 0.366 92.2% 2624 0.379 92.5% 3157 0.392 % Efficiency .. . : 87.S% ' 88.2% ' 89 1% 41/,'' i Savings .......... : 245 : 412 630 /z : UnitLoss............ 1 0.268 0 281 0 294 89 7% 876 0 306 90 4% 90 9% 1175 1S17 0 319 ' 0.331 91.4% 1 918% 1 92.3% 1916 ' 2366 j 2902 0.344 ! 0.3S7 0.369 92.7% 3493 0.382 % Efficiency ... ; 87.6% ; 88 3% 89 3% 89 9% 90 S% : 91 0% 91.6% 92.0% I 92.4% 92.8% 1 5" l Savings................. i 271 ; 4S6 ; 698 970 1303 ; 1682 212S 262S 3221 3879 V 1 UnitLoss........ I 0.262 1 0 275 0 287 0 299 0 312 : 0 324 0.336 0.349 | 0.361 0.373 % Efficiency . . . 88 0% 88.6% 89 5% 90 1% ' 90 7% 91 3%- : 91.8% 92.2% I 92.6% 93.0% 6" Saving*................ 321 1 538 824 1146 ; 1S36 1985 ; 2510 3104 1 3811 4601 Unit Lot*............ 0.253 1 0 '65 0 277 0 289 0 301 0 313 1 0.325 0.337 l 0.349 0.361 ] % Efficiency . . . 7" 1 Savings ..... . . ! Unit Loss............ 88.1% 366 0.248 88.8% 615 0.2S9 89 7% 940 0 271 90 3% 1314 0 282 90 9% 1756 0 294 , 91 4% 1 91.9% 2271 ! 2874 0 306 | 0.317 92.3% 3SS6 0.329 92.8% 4369 0.341 93.2% 5278 0.352 % Efficiency ... 88.2% 88.9% 89 8% 90 4% 9j 0% | 91.5% : 92.0% 92.4% 92.8% 93.2% 8" Savings................ 411 691 1056 1478 1975 ' 2557 | 3228 4007 4914 5939 Unit Los*............ 0.243 0 254 0.266 0 277 0 289 j 0 300 : 0.312 0.323 0.33S 0.346 % Efficiency . .. 88.3% 89 0% 89 8% 90 5% 91 1% ; 91 6% 92.0% 92.5% 92.9% 93.3% 9" Savings................ 455 765 1171 1 1639 . 2194 | 2840 3S89 4456 5467 6595 Unit Loss............ 0.239 0.250 0 262 1 0 273 ' 0 284 j 0.296 0.307 0.318 0.330 0.341 _. 10* I % Efficiency ... ] 1 Savings.............. { i Unit Lom.......... : 50$ 0.235 89 1% . 90 0% , 8S1 ; 1298 0.246 ! 0.257 90 6% 1818 0 268 91 2% 1 91 7% ! 92 1% 2435 i 3154 : 3987 0 279 j 0.291 i 0.302 92.6% 4953 0.313 93.0% 6079 0.324 93.4% 7336 0.33S 12" 14" % Efficiency . . . Savings................ Unit Lot*............ % Efficiency . .. Savings................ Unit Los*............ 88.5% 595 0.230 88.5% 645 0.228 89 2% ; 90 1% 1003 | 1530 ! 0.241 | 0.2S2 | 90 7% 2138 0 263 89.2% I 90 1% j 90 7% 1088 1 1663 1 2325 0.239 | 0.250 1 0 261 91 2% 2865 0.274 91.3% 3119 0 272 91.8% 3716 0.285 91.8% 4047 0.283 92.2% 4726 0.297 92.3% 5124 0.293 92.6% 5842 0.308 92.7% 6373 0.304 93 1% 7175 0.319 93.1% 7811 0.31S 93. S% 8663 0.330 93.5% 9457 0.326 16" % Efficiency . . . Savings................ Unit Loss............ 88.6% 730 0.225 89.3% 1233 0 236 90 2% 90 8% 1886 ! 2639 0.246 ' 0 257 91.3% 3S42 0 268 91.9% I 92.3% 4601 5826 0 278 0.289 92.7% 7211 0.300 93.2% 8889 0.311 93.6% 10767 0.321 18" % Efficiency .. . Savings................ Unit Loss............ 88.7% 820 0.222 89.4% 138S 0.233 90 2% ; 90 8% 2119 2955 0.244 | 0.2S4 91.4% 3969 0.26S 91.9% 5159 0.275 92.4% 6S36 0.286 92.8% 8094 0.297 93.2% 9984 0.307 93.6% 1209S 0.318 Flat Vertical 1H" Th'k % Efficiency ... Savings................ Unit Los*............ 90.4% 193 0 204 91 1% 328 0 214 91.7% 1 92 2% 495 689 0 224 1 0.234 92 6% 917 0.244 93.0% 1185 0.2S4 93.4% 1494 0.264 93 8% 1852 0.274 94.1% 22S3 0.284 94.4% 272S 0.29S All dmtm from Mellon Institute, University of Pittsburgh rests. HEAT INSULATION DATA BASE THERMAL TABLE 2" Thickness EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Savings art in ft. T. U. per linear foot of pipe per hour. Unit losses are in ft. T. U. per square foot of pipe surface per hour per 9F. temperature difference between pipe and surrounding air. TEMPERATURE DIFFERENCE *F. BETWEEN PIPE AND SURROUNDING AIR Size ; 100 150 200 250 300 350 400 430 [ % Efficiency ... W I Unit Loss............ f % Efficiency . .. %" ' Savings.................. ' Unit Loss............ . % Efficiency . .. r 1 Savings................ ' Unit Loss............ W % Efficiency . . . Savings................ Unit Loss............ % Efficiency . .. w Savings................ ' Unit Loss............ % Efficiency ... 2' Savings................ Unit Loss............ W % Efficiency . .. Savings................ Unit Loss............ % Efficiency . . . 3' Savings................ Unit Loss............ zw % Efficiency ... Savings................ Unit Loss............ % Efficiency . .. 4" Savings................ Unit Loss............ 41/2' % Efficiency . . . Savings................ Unit Loss............ % Efficiency . . . 5" Savings................ Unit Loss............ % Efficiency . . . 6' Savings................ Unit Lott............ % Efficiency . . . 7" Savings................ Unit Loss............ % Efficiency . .. 8" Savings................ Unit Loss............ % Efficiency . .. 9" Savings................ Unit Loss............ 10' % Efficiency . .. Savings................ Unit Loss............ 12' % Efficiency . .. Savings................ Unit Loss............ 14" % Efficiency . .. Savings................ Unit Loss............ 16' % Efficiency .. . Savings................ Unit Loss............ 18' % Efficiency ... Scvings................ Unit Lou............ Fiat Vortical 2' Th'k % Efficiency .. . Savings................ Unit Lou............ 81 6% . 82.7% 45 . 75 0.457 . 0.478 83.3% ! 84.3% 56 [ 94 0.407 i 0.425 84.7% i 85.7% 69 1 0.363 1 117 0.380 86.1% 86 9% 88 : 148 0.326 0.341 86.7% 100 0.307 87.6% 124 0.282 87.5% 168 0 321 88 3% 208 0 295 88.3% 148 0.262 89 0% 249 0.274 88.9% 179 0.245 89 6% 302 0 256 89.2% 204 0.236 89.4% 228 0.228 89 8% 343 0.247 90.1% 384 0.239 89 6% 2S1 0.222 90 3% 422 0 232 89.8% 278 0.216 90 4% 467 0 226 90.1% 329 0.207 90.7% S50 0.217 90.3% 376 0.201 90 9% 630 0.210 90.5% 422 0.196 91.0% 707 0 205 90.6% 467 0.192 91.1% 784 0.201 90.7% 519 0.189 91 2% 871 0.198 90.8% 611 0.184 91 4% 1027 0.193 90.9% 662 0.182 91.4% 1115 0 191 90.9% 749 0.179 91.5% 1263 0.187 91.0% 841 0.177 91.6% 1419 0.185 92.5%, 197 0.1S9 93.1% 335 0.166 83.9% 114 0.498 85.6% 145 0.443 86. t% 178 0.396 87.9% 225 0.356 88 4% 255 0.335 89 2% 316 0 308 89 8% 380 0.286 90 3% 4S9 0 268 90.6% 520 0.2S8 90.8% 583 0 249 91.0% 644 0 242 91.2% 713 0 236 91.5% 842 0.226 91 6% 960 0.220 91.8% 1079 0.214 91 9% 1197 0.210 91.9% 1326 0.207 92 1% 1564 0.201 92.1% 1700 0.199 92.2% 1928 0 196 92 2% 2167 0 193 93.6% SOS 0.174 84.8% 1S9 0.519 86.2% 199 0 462 87.4% 247 0.413 88.5% 312 0.371 89 1 % 3SS 0.349 89 8% 438 0.321 90.4% 527 0 298 90.9% 638 0.279 91.2% 723 0.268 91.4% 811 0 260 91 5% 893 0.2S3 91.7% 989 0.246 91 9% 1169 0.236 92.1% 1341 0.229 92.3% 1508 0.223 92 4% 1673 0.219 92. S% 1856 0 215 92 6% 2185 0.210 92.6% 2374 0.208 92.7% 2695 0.204 92.7% 3017 0.202 93.9% 702 0.181 6osoMr tc * M O 9i 85.6% 212 0.540 86.9% 264 0 480 88.1% 329 0 429 89.2% 416 0.386 89 7% 472 0.363 90 4% 520 0.334 90.9% 703 0.310 91.4% 850 0.290 91.7% 965 0.279 91 9% 1082 0.270 92.0% 1197 0 263 92 2% 1327 0.2S6 92.5% 1S65 0.245 92.6% 1789 0 239 92.8% 2014 0.232 92 9% 2481 0.224 93.0% 2920 0.219 93.0% 3180 0.216 93.1% 3611 0.213 93.2% 4047 0.210 94.3% 933 0.189 All ctore itom Mellon Inttitute, University of Pittburh tests. 86 3% 273 . 0.561 87.6% 340 0.498 88.7% 423 0.446 89 7% 534 0 401 90.2% 609 0.378 90.9% 754 0.347 91.4% 906 0.323 91.9% 1097 0.302 92 1% 1246 0.290 92.3% 1394 0.231 92.5% 1S44 0.273 92.7% 1712 0.266 92.9% 2020 0.255 93.0% 2311 0.248 93.1% 2603 0.242 93.2% 2893 0.237 93.3% 3211 0.233 93 4% 3783 0.228 93.5% 4122 0.225 93.5% 4685 0.221 93 6% 5253 0.218 94 6% 1205 0.196 87.0% 342 0 581 88 3% 427 0.516 89 3% 532 0.462 90.3% 673 0 415 90.7% 765 0 392 91.4% 951 0 3S9 91.9% 1143 0.33S 92.3% 1382 0.313 92.6% 1570 0.301 92 8% 1759 0.291 92 9% 1948 0 283 93 1% 2161 0.275 93.3% 2552 0.265 93.4% 2922 0.257 93.5% 3284 0.251 93 6% 3650 0.246 93.7% 4054 0.242 93.8% 4807 0.236 93.9% 5212 0 233 93.9% 5926 0.229 94.0% 6649 0.226 94 9% 1518 0.204 87.6% <*22 0.632 88.5% 527 0.534 89 8% 656 0.480 90 8% 830 0.430 91.4% 967 0 406 91 8% 1172 0.372 92.3% 1411 0.347 92.7% 1707 0 324 93.0% 1940 0.312 93.1% 2174 0.302 93.3% 2403 0.293 93 4% 2667 0 285 93 6% 3153 0.274 93.8% 3612 0.267 93.9% 4072 0.260 94.0% 4S28 0.255 94.1% 5031 0.251 94 2% 5936 0.24S 94.2% 6475 0.242 94.2% 7328 0.238 94.3% 8227 0.234 95.2% 1881 0.211 500 550 80 2% 514 0 623 89.4% 643 0.5a3 90.4% 802 0 495 91.3% 1012 0.44S 91 7% 1153 0.420 92.3% 1432 0.385 92 7% 1725 0.359 93.1% 2088 0.335 93 4% 2376 0.322 93.5% 2663 0 312 93.7% 2945 0.304 93.8% 3270 0 29S 94.0% 3868 0.264 94. J% 4434 0.276 94.3% 4989 0.269 94.3% 5550 0.264 94.4% 6171 0.259 94.5% 7283 0.254 94.S% 7930 0.250 94.6% 9025 0.246 94 6% 10134 0.243 95 4% 2286 0.219 8S 8% 613 0 643 89 9 <7 771 0 S71 90.9% 963 0.512 91.7% 1215 0 460 92.1% 1385 0 434 92.7% 1721 0.398 93.1% 2074 0.371 93. S% 2513 0.347 93 7% 2854 0.333 93 9% 3201 0.323 94.0% 3542 0 314 94.1% 3933 0 305 04.3% 4466 0.273 94.4% 53S0 0.286 94 6% 6024 0.278 94 6% 6690 0.273 94 7% 7440 0.268 94.8% 8788 0.262 94.8% 9592 0.259 94.9% 10919 0 255 9S 0% 12269 0.2S1 95 7% 2763 0.226 ?-4 INS TOd.A.Ol? HEAT INSULATION DATA BASE THERMAL TABLE 2 V:" Thickness EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Saving* ore in B. T. U. per linear foot of pipe por hour. Unit losses are in B. T. U. per square foot of pipe surface per hour per F. temperature difference between pipe and surrounding air. Size TEMPERATURE DIFFERENCE `F. BETWEEN PIPE AND SURROUNDING AIR TOO 150 200 250 300 350 400 450 1 % Efficiency . . . 1 83.2% W | Savings................ i 45 [ Unit Loss............ : 0.417 % Efficiency . .. i Savings................ ! Unit Loss............ { 84.9% S7 0.368 % Efficiency . .. i 86.2% 1" Savings................ 71 Unit Loss............ ! 0.329 f 1 % Efficiency . . . ! 87.4% l]/' Savings................ i 89 I Unit Loss............ ; 0.294 iy2- , % Efficiency . .. j ; Savings................ Unit Loss............ j 88.1% 101 0.274 % Efficiency . . . ; 89.0% 2" Savings ................. ! 126 Unit Loss............ ! 0.249 2W % Efficiency . . . i Savings................ Unit Los*............ { 89.6% ISO 0.232 % Efficiency . . . 90.3% 3' Savings................ 182 Unit Loss............ 0.214 % Efficiency . . . | Savings................ Unit Los*........... 90.6% 207 0.204 % Efficiency . .. 90.9% 4' Savings................ 231 Unit Loss............ 0.197 4i/2' % Efficiency . . . Savings................ Unit Los*............ 91.1% 255 0. 191 % Efficiency . . . 91.3% S" Savings .............. 282 Unit Loss ...... 0.185 % Efficiency . . . 91.6% 6' Savings................ 334 Unit Loss............ 0.177 % Efficiency . . . 91.8% 7" Savings................ 382 Unit Loss............ 0.171 % Efficient . . . 91.9% 8' 428 Unit Los* .......... 0.166 9" 10" 12- 1416- % Efficiency . .. Savings .............. Unit Los*............ % Efficiency . . . Saving*................ Unit Loss............ % Efficiency . . . Savings................ Unit Loas............ % Efficiency ... Savings................ Unit Loss............ % Efficiency . . . Saving*................ Unit Loas............ 92.1% 474 0.162 92.2% 527 0.159 92.3% 620 0.155 92.3% 673 0.153 92.4% 761 0.150 18- | % Efficiency . . . Saving*................ i Unit Loss............ Flat Vortical 2M' Th'k % Efficiency ... Savings................ Unit Loss............ 92.4% 854 0.149 94.0% 200 0.128 84.2% . 85.3% ' 86 1% 77 ; 116 162 0.436 1 0.455 0.473 8S. 7% 96 0.385 87.0% 147 0.401 87.5% 202 0 418 87.1% 119 0.343 88.0% 180 0.3S8 88.7% 2S1 0.373 88.2% 150 0.307 89.1% 228 0.320 89.7% 316 0.333 88.8% 171 0.287 89.7% 259 0.299 90.3% 360 0.312 89.7% 211 0.261 90.2% 2S3 0.243 90.5% 321 0.272 91.0% 385 0.253 91.0% 444 0.283 91.5% S34 0.264 90.9% 306 0.224 91.6% 465 0.234 92.0% 646 0.244 91.2% 348 0.214 91.9% 527 ' 0 223 92.3% 732 0.232 91.5% 390 0.206 92.1% S91 0.215 92 9% 824 0.224 91.6% 429 0.199 92.3% 653 0.208 92 7% 905 0.217 91.8% 474 0.194 92.5% 723 0.202 92.9% 1002 0 211 92.1% 559 0. IRS 92.7% . 8S3 0 193 93 1% 1184 0 201 92.3% 639 0.179 92.9% 973 0.187 93 3% 1358 0.194 92.4% 718 0.174 93 0% 1094 0.181 93 5% 1527 0 189 92.5% 795 0.170 93.1% 1214 0.177 93 6% 169S 0.185 92.7% 885 0.166 93 2% 1344 0.174 93.7% 1880 0.181 92.8% 1042 0.162 93.4% 1586 0.169 93.8% 2210 0.176 92.8% 1132 0.160 93.4% 1724 0.167 93 8% 2405 0.174 92.9% 1282 0.157 93.4% 1955 0.164 93.9% 2729 0.171 92.9% 1440 0.155 93 5% 2196 0.162 93.9% 3055 0.169 94.4% 340 0.134 94.8% 512 0.140 95.1% 711 0.146 86.9% . 21S 0.492 88.1% 268 0.435 89.3% 334 0 388 90.3% 421 0.346 99.8% 477 0.324 91.S% 592 0 295 92.0% 711 0.274 92.5% 860 0.254 92.8% 976 0.242 93.3% 1099 0.233 93.2% 1212 0.226 93.3% 1343 0.219 93.6% 1S84 0 .'209 93 7% 1811 0.202 93 8% 2038 0.197 94 0% 2263 0 192 94.0% 2511 0 189 94.1% 2955 0.184 94 2% 3219 0.181 94.2% 3655 0.178 94.3% 4095 0.176 95.4% 944 0.152 87.S% 276 0.511 88.8% 344 0.452 89.9% 428 0.402 90.8% 541 0.3S9 91.3% 616 0.337 92.0% 763 0.306 92.4% 916 0 285 92.9% 1109 0.264 93 2% 1260 0.2S1 93.4% 1410 0.242 93 6% 1562 0.234 93.7% 1731 0.228 93.9% 2043 0.217 94.1% 2338 0.210 94.2% 2632 0.205 94.3% 2925 0.200 94.4% 3248 0.196 94.5% 3826 0.191 94. S% 4169 0.188 94.6% 4737 0.185 94.7% S313 0.182 95.7% 1219 0.158 88.1% 347 O.S30 89.4% 433 0 468 90.7% 540 0.417 91.3% 680 . 0.373 91.8% 773 0.349 92.4% 961 0.318 92.9% 1155 0.295 93.3% 1396 0.274 93.6% 1587 0.261 93 8% 1777 0 251 93.9% 1969 0.243 94.1% 2184 0.236 94.3% 2579 0.226 94.4% 2954 0 218 94.5% 3319 0.212 94 6% 3689 0.208 94.7% 4098 0.203 94.8% 4858 0.198 94.9% 5267 0.195 94.9% 5988 0.192 95.0% 6719 0.189 95.9% 1534 0.165 88.7% 427 0.S49 89.9% S33 0.485 90.9% 664 0.432 91.7% 839 0.386 92.3% 977 0.302 92.8% 1184 0.329 93.2% 1425 0.306 93.7% 1724 0.283 93.9% 1960 0.270 94 1% 2196 0.260 94.2% 2428 0.252 94 4% 2693 0.245 94.6% 3184 0.234 94.7% 3649 0.226 94.8% 0.220 94 9% 4S73 0.215 95.0% S082 0.211 9S. 1 % 5997 0.205 95.2% 6S41 0.202 95.2% 7403 0.198 9S. 2% 8308 0.196 96.1% 1899 0.171 All dere from Mellon Institute. University of Pittsburgh tests. soo 89.3% 521 0.567 90.4% 650 0.502 91 4% 811 0 446 92.2% 1022 0.399 92.6% 1164 0.374 93.2% 1446 0.340 93.6% 1741 0.316 94.0% 2108 0.293 94.3% 2398 0.279 94.4% 2689 0.269 94.6% 2973 0.261 94.7% 3300 0.253 94.9% 3904 0.242 95.1% 4477 0.233 9S. 1 % 5035 0.228 95.2% 5602 0.223 95.3% 6228 0.218 95.4% 73S2 0.213 95.4% 800S 0.209 95.S% 9111 0.205 95.5% 10229 0.203 96.3% 2307 0.177 350 89.8% 625 0.586 90.9% 779 0.518 91.8% 972 0.461 92.6% 1227 0.412 93.0% 1398 0.387 93.5% 1737 0.352 93.9% 2093 0.327 94.3% 2535 0.303 94.5% 2880 0.289 94.7% 3231 0.278 94.9% 3S74 0.269 9S. 0% 3968 0.262 95.2% 4707 0 250 95.3% 5400 0.241 9S 4% 6076 0.236 95.5% 6749 0.230 95.5% 7505 0.226 9S. 6% 886S 0.220 95.7% 9678 0.216 9S. 8% 11018 0.212 95.8% 12378 0.209 96.5% 2787 0.183 Itlr HEAT INSULATION DATA BASE THERMAL TABLE 3" Thickness EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Sovingt ere in B. T. U. per linear foot of pipe per hour. Unit losses ere in B. T. U. per square foot of pipe surface per hour per eF. temperature difference between pipe and surrounding air. Pipe Size TEMPERATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNOING AIR 100 150 200 230 300 330 400 450 I % Efficiency .. . 1 84.39c i 85.3% W { Savings................ ] j Unit Loss............ ] 46 ' 0.388 78 0.406 i % Efficiency . .. ! 86.0% 86.8% | Savings................ 57 1 97 1 Unit Loss............ 1 0.341 1 0.357 ! % Efficiency ... ! 87.3% 1" ' Savings................ | Unit Loss............ \1 0.30721 88.1% 120 0.31S 1%' % Efficiency . .. Savings................ Unit Loss............ 88.69c 90 0.267 89 3% 1S2 0.280 V/z" 2" % Efficiency ... Savings................ Unit Loss............ % Efficiency . . . Savings................ Unit Loss............ 89.2% 103 0.250 90.0% 127 0.226 89.8% 172 0.262 90.6% 213 0.236 2Vz" % Efficiency ... Savings................ Unit Loss............ 90.7% 152 0.208 91.2% 2S6 0.218 % Efficiency . . . 91.3% 91.8% 3" Savings................ 184 309 Unit Loss............ 0.192 0.201 3y2" % Efficiency ... Savings................ Unit Loss............ 91.6% 209 0.184 92.1% 351 0.192 4" *5e Efficiency . .. Savings................ 91 9% 234 92 4% 394 Unit Loss............ 0.176 0 184 41/2" % Efficiency . . . Savings ............... Unit Loss............ 92.1% 2S8 0.170 92.5% 433 0 178 % Efficiency . - . 92.3% 92 7% 5" Savings................ 285 479 Unit Loss............ 0 164 0.172 6" % Efficiency . . . Savings................ 92.6% 337 93.0% 564 Unit Loss............ 0.156 0.163 7" % Efficiency . . . Savings................ 92.7% 386 93.2% 646 Unit Loss............ 0.1S1 0. 1S7 8" % Efficiency . . . Savings................ 92.9% 433 93.3% 725 Unit Loss............ 0.146 0.153 % Efficiency . . . 93.0% 93.4% 9" Savings................ 479 803 Unit Lot*............ 0.142 0.149 10' % Efficiency ... Savings................ Unit Loss............ 93.2% 533 0.139 93.5% 893 0.146 12" % Efficiency . .. Savings................ Unit Loss............ 93.3% 627 0.135 93 7% 10S3 0.141 14" % Efficiency ... Savings................. Unit Loss............ 93.4% 681 0.132 93.7% 1143 0.139 16' % Efficiency ... Savings................. Unit Loss............ 93.4% 770 0.130 93.8% 1295 0.136 18" % Efficiency ... Savings................. Unit Loss............ 93.5% 865 0.127 93.9% 1455 0.133 Fit Vertical 3" Th'k % Efficiency ... Savings ................ Unit Loss............ 94.9% 202 0.109 95.3% 343 0.114 86.4% 118 0.423 87.9% 149 0.372 89.0% 182 0 329 90.1% 230 0.292 90.6% 262 0.273 91.4% 324 0.246 91.9% 389 0.227 92.4% 470 0.210 92.7% 532 0 200 92.9% S96 0.192 93.1% 6S9 0.186 93.3% 729 0.179 93.6% 861 0.170 93.7% 982 0 164 93 9% 1104 0.1S9 94 0% 122S 0.1SS 94 1% 1357 0.152 94 2% 1600 0.147 94.2% 1740 0.145 94.3% 1972 0.142 94.4% 2218 0.139 95.6% 516 0.120 87.1% 163 0.441 88.4% 204 0.388 89.6% 253 0.343 90.6% 319 0.304 91.1% 363 0.284 91.8% 448 0.257 92 4% 539 0 237 92.8% 651 0.219 93.1% 738 0.209 93 4% 828 0 200 93 . S% 913 0.193 93.7% 1011 0 187 93 9% 1194 0.178 94.1% 1370 0 171 94.3% 1540 0 166 94 4% 1709 0.162 94.5% 1896 0.1S8 94.6% 2230 0.1S3 94.6% 2426 0.1S1 94.7% 2754 0.147 94.7% 3084 0.145 95.8% 716 0.125 87 8% 217 0 458 89.0% 270 0.403 90.2% 337 0.3S6 91.2% 425 0.316 91.6% 482 0 296 92.3% S98 0.267 92.8% 717 0.246 93.3% 867 0.227 93.5% 984 0.217 93.8% 1104 0.206 93.9% 1222 0 201 94.1% 13S4 0.194 94.3% 1S96 0.185 94.5% 1825 0.178 94 6% 20S4 0.173 94.7% 2282 0.168 94.8% 2S31 0.165 94 9% 2981 0.159 95.0% 3245 0.1S7 95.0% 3687 0.153 95.1% 4131 0.151 96.1% 951 0.130 All deta from Mailon Institute, University of Pittsburgh tests. 88.4% 279 0.476 89.6% 348 0 418 90.7% 432 0.370 91.6% S45 0.328 92.1% 621 0.307 92.7% 769 0.277 93.2% 924 0.2S5 93.7% 1118 0.236 93 9% 1270 0.225 94.1% 1421 0 216 94.3% 1S73 0.209 94.4% 1744 0.202 94.6% 20S9 0.192 94 8% 23S6 0.185 94.9% 2653 0.179 95.0% 2947 0.175 95.1% 3272 0.171 95.2% 3856 0.165 95.3% 4201 0.163 9S.4% 4775 0.159 95.4% 5354 0.157 96.3% 1227 0.135 89.0% 350 0 493 90 1% 436 0.434 91.2% 543 0.383 92.1% 686 0.340 92.5% 779 0.318 93.1% 969 0.287 93 6% 1164 0.265 94.0% 1407 0.245 94.2% 1598 0.234 94 4% 1790 0.224 94.6% 1983 0.216 94.7% 2199 0.209 94 9% 2598 0.199 95.1% 2975 0.191 95.2% 3342 0.186 95.3% 3716 0.181 95.4% 4127 0.177 95.5% 4893 0.172 95.5% 5305 0.169 95.6% 6033 0.16S 9S. 7% 6770 0.162 96.5% 1544 0.140 89 5% 431 0.511 90.6% 537 0.449 91.6% 669 0.397 92.5% 845 0.3S2 93.0% 984 0.330 93.5% 1193 0.298 93.9% 143S 0.274 94.3% 1736 0.254 94 5% 1973 0.242 94 7% 2211 0.232 94.9% 2444 0.224 95.0% 2712 0.217 95.2% 3206 0.206 95 4% 3674 0.198 95.5% 4140 0 193 95 6% 4604 0.188 95.6% 5116 0.184 95.8% 6037 0.178 95.8% 6585 0.17S 95.9% 74S4 0.171 95.9% 8367 0.168 96.7% 1910 0.145 500 90.0% 525 0.528 91.1% 655 0.465 92.0% 817 0.411 92.9% 1030 0.364 93 2% 1173 0 341 93 8% 1456 0.308 94 3% 1753 0.284 94.6% 2122 0.262 94.9% 2413 0.250 95 0% 2706 0.240 95.2% 29C2 0.232 95.3% 3321 0.224 95. $% 3929 0 213 9S.6% 4505 0.205 95.7% 5068 0.199 95.8% 5638 0.194 95.9% 6268 0.190 96 0% 7400 0.184 96.0% SOS 7 0.181 96.1% 9169 0.177 96.2% 10297 0.174 96.9% 2320 0.150 350 90.5% 630 0.545 91.5% 785 0.480 92.4% 979 0.4?4 93.2% 1235 0.376 93.6% 1407 0 352 94 1% 1749 0 318 94 s% 2107 0.293 94 9% 2552 0.271 9S 1% 2897 0 259 95 :% 3250 0 248 9S 4% 3596 0 239 95.5% 3992 0.232 9S. 8% 4736 0.220 95.9% 5432 0.212 96 0% 6114 0 206 96.1% 6790 0.201 96.1% 7SS2 0.196 96.2%. 8920 0.190 96 3% 9737 0.187 96 3% 11085 0.183 96 4% 12453 0. 180 97.0% 2802 0.155 c HEAT TRANSMISSION FROM SURFACES BULLETIN 102.A E S T. 18 7 3 \ THE PHILIP CAREY MFG. COMPANY General Officer -- LOCKLAND, CINCINNATI, OHIO Branchas la AH Principal Chit* HEAT TRANSMISSION FROM SURFACES Bulletin No* 102 A THE PHILIP CAREY MFG. COMPANY CINCINNATI, OHIO R. H. Heilman's paper "Surface Heat Transmission,''Trans. Am. Soc. Mech. Engrs., Fuels Steam Power, 51, 257 (1929), gives a sound basis for determining losses, savings to be made by the use of heat insulation, and the per cent efficiency of such insulation. Many and conflicting claims of efficiency have been made for various commercial heat insulations. It is obvious that the efficiencies and savings cannot be compared unless the same heat losses from the bare surfaces are used as a basis. As mentioned in the paper above, several types of commercial shapes, such as pipes and flat plates, were tested. From the results of those tests a formula was developed for the transfer by free convection, and emissivity values were determined for various surfaces for use in the Stefan-Boltzmann radiation formula. The separation of heat transmission from a surface to the sur rounding air into its two components--radi ation and convection--greatly extends the range of usefulness of former tests on bare and insulated surfaces. By means of these two formulae and the emissivity of various surfaces, one is able to calculate the rate of heat transfer under still air conditions for practically any shape or type of surface and for any temperatures ordinarily met with in engineering practice: The formulae are as follows: qc=C(')J ( --)-181 At1'** Ls 1 aog. --10 <^r=! 7.4 x 10 x e (Tx4 -- T24) where qc=heat transfer by free convection in Btu per sq. ft. per hr. C=a constant depending upon the shape of the surface. (C--1.016 for horizontal cylinders,=1.235 for long vertical cylinders, = 1.394 for vertical plates,=1.79 for horizontal plates facing upward, and=0.89 for horizontal plates facing downward. The constants for the horizontal plates facing up ward and facing downward are reversed when the plates are cooler than the surrounding air.) D=cylinder diameter in inches or height of vertical plane in inches. (The effect of diameter or height becomes constant at a value of approximately 24 inches.) T ai>.=460 plus the average of cylinder or plate surface and surrounding air temperature in deg. Fahr. 2 At=temperature difference (deg. Fahr.) between surface and air. q^heat transfer by radiation in Btu per sq. ft. per hr. ^=emissivity of surface. (A value of 0.9 can be assumed as the emissivity of most industrial surfaces, such as brick, stone, glass, canvas, asphalt roofing and various colored flat paints at temperatures below 400 deg. Fahr. For highly polished met als "e" may be as low as 0.02.) Ti=temperature of the hotter sur face, deg. Fahr.+460. T2=temperature of surrounding ob jects, deg. Fahr.+460. The bare pipe loss curves, the bare pipe loss tables, the surface loss curves for various outside diameters and the surface heat trans mission from flat bare steel surfaces, con tained in this bulletin, were all calculated with the above formula for free convection and radiation. The calculations were all based on an air temperature of 80 deg. Fahr. and with the surfaces at higher temperatures than the surrounding atmosphere. Effect of Wind The formula given above for free con vection cannot be used for conditions where extraneous air currents are blowing over the surfaces. In this case the heat transfer takes place by forced convection and radiation. The forced convection for large bare plane surfaces greater than two feet on a side, can be obtained from the formula q/c=1.+0.225V. where qyc=heat transfer by forced convec tion in Btu per hr. per sq. ft. per deg. Fahr. temp. diff. V=air velocity in feet per sec. This formula is an approximate average of formula proposed by various investigators. The heat transmission curves shown on page 10 for large bare surfaces with various wind velocities were calculated from the above formula and the radiation formula. In this case an air temperature of 70 deg. Fahr. was assumed. The data available on forced convection at present are not sufficient to enable one to differentiate to any degree of accuracy be tween the losses from plane surfaces in the various positions. Considerable experimental work has been done on forced convection from wires and cylinders. The forced convection for air flowing at right angles to various sized single horizontal cylinders can be obtained from Reiher's equation which is as follows: k ,DV/3}.56 w-35 n( where qyc=surface conductance, Btu/sq. ft./hr./F. k=thermal conductivity of air Btu/ft./hr./F. D=outside diameter of pipe, ft. V=air velocity, ft./hr. ^^Jensity of air, lb./ft.3 viscosity of air, lb./ft.--hr. The heat transmission curves shown on page 9 for various diameter bare steel pipes with various wind velocities were calculated from the above formula and the radiation formula. In this case also, an air tempera ture of 70 F. was assumed. Losses F rom H o riz o n ta l B are Steel Steam Pipes F ro m 100 L in e a r F eel o f P ipe per M o n th o f 30 D a y * W ith S team in P ipes 24 hours per D a y. C oal a t $7.00 per T o n o f 2000 Lbs. 792 7.44 191 9 per < : JH. `wa'i/wj P*wn/ug C wi . * &!H id panoj mS*iNrNWimsr>*eiNmMrN>A> -- q^N-#'NOT#'N^-NT-<e -- -- -- -- -- -- IN IN ^Sm'* -- Pmi*ain -- mN^f>-iN0 - m in in N- in i*Ami"*<',\r**riAiNiNiN^ > IN : *^na "Cwa *Jo 7aooj *b0 *Si1 . i j^ 5 3 1 taun nag iTMo spunoj 8? "n*ona s J5 - I s iroun/tug P0 spunoj noa lAIiNAINOfrNm N-- N-- NlAC'meiT-- i'NC--NV-- eiCff' TNWiXe1'' - iX in u*s -- eNmmiN----iN--m--^f'---INiNINVI'NrNiNNmr'w^^' -- -- - m -- m - -- m -- <Nm^ -- in in -- f* Nm m-- i--n -- imn o^ N (S W (I ^ US lA N in V in -- n in CO 'T n-- N iA IN C -- ANNe^-A-- A^lCiAANAeee-cN>lAANV^ o n-- jl--t--AS-- O--NN>ANNC-- '(IAA--^^IAA--lAN mm^ 8 8 U"\ m v e IA l>i <Q ^ r**. AN IN tOlAiA^W-N<t^AttNNO AeN3NN-'i--A'AiAjlAeeNtOlA--m-6-S^AN-IN '-NAi(fi(*il*'T1'iA^N#^d-l*!t -- -- -- ia r*. Nm ImN ^fAk f N IA V lA N S_ IA IA N lA N ^ r*. ^ N A > IA N in 4-- A i--n mieAne* IN IN IN - N IN IA N N -' lA - - (N IN ._ OV A IA IA ,fl|./,fl!a`i./Mi iwon/^a PD spunoj *n "Tta i^n/^a PD spano^ 1 "iia ,jH/*}j!a `do /*<d i*un/n*8 PD cpuno^ "na i~n/n4a 1*0 tpunoj wnoQ s IN fN IN 5 IN fA -- -- AN -- IN -- - an IN IN X fA e r* IN n- (A r o IN V -- -- to s AM N S A iA e fA 8 IN T 2 r^s IN ? e IN ftAA es fSs lA <N O<N' <PNA *r IN 5 $ rs fN tn <x * m IN ts IN m I9N fA m IN IN mr X m m X NMA X V o PA SIN s n -- ia ia * m (IAA_ fIf|Nt.-ma0# NV9S>NOrNVAOrAAOiAAe>jl`AATiA4NlAIAAlA.N-- ' -- -- IN IN` IN` m` ` ttri<e4Kfl9'9'N _ A --A A^A imIIAA -^--INlpOIN l--Nm. mm. m. inn.*--- -- -- NIAtANN^ -- IN ^ IN o-- t IN Ap*. ^ tIAtNC--N^^NNN-Pt#N V-- r-- oIN ItN eIN m* ^CA^ilON' -- IA-- N*d AIAVAAliN0<> l^f**\ --I--N I<Nn 1*1 ^IN -- N V IN IA Nn. --fOm N IiNn IAin tA^ A-- a-mN--Ai/a AilAIAIAVAAdNNdd^N T-5OI'>TAAO8KSTAANifAlNlNNON9NieAAiAIeA9-A'fdl-tNIrA'-NIAAtAiiCNe-NmAN#INT -- -- -- -- -- -- ININ <rAYOONN -- NlAe^N tN>0 -- ^ IN -- mININinin ^m -- -- VVANS9> m <A AN A IN ?Ml I(N. -- -- - fsj IN IN m PA V TAIAN9 699 IN o $ PfAA O' l*k IN oIN IN As o(A m m N IN N IA IA IN ^ ^ S A-- A(*l NN IAN 8 In SO IN IAN fN fN -- i*i rN -- mm -- m in -- AN IN rNiNiNmiN -- -- m -- mV -- mV............................................ &n f fill 6' Ocl! r**"n/na 1*0 *Punod *n "na $8 UA AN S5 -- in m NANNO-IANfN 8 -- t66ttiaia -- Jh -- iA IN m -- -- IN m IN IN -- iNiNiNiNmmVVknViN -- 'emmiNiN -- m mm-- A-- --BiON-- i--NNeftNB2cNN2OmsNmO^A^cmA<mIASArN>n IN IN IN AN m in in in m -- n m kX IN -- m^ -- m -- -- -- -- IN in in Sn *!S **M eNiANoNirc MV i^ -` i* * _S* e 3 -z e 8 >> e -- e -2 vv 22 C r.f *2 o a B o & e2 8& N Ld e9 *j 21 i I c I 13 J " "5 *" S i m 0%- 8 0 c. 1 8 u. i , t> s > S m 'S - < ^s MO l a CL CO S r otc cn u zU- H j o o Oz in _1 O' in uj tig - > ccr A "Se (0 z < f > gd Q UJ tz <0kt h- L-OiOu sl? Ui X CD o l: o cJ X -y CL t or (0 CC u CL cc X tO X Ui a. =J to z' o <n co f cO z < X h* ui X oa (0 1/1 * ou -* Q_ uJ st: > r> h- 0 o y ou <r sT- Carey Heat Insulating Materials High Temperature Surfaces (1000F. to 2500 F.) Carey Hi-Temp No. 19--An efficient insu lator consisting essentially of a mixture of diatomaceous earth and asbestos fibre bonded and molded into commercial size blocks. This material is designed to give maximum efficiency with structural in tegrity in the temperature range from 1500 F to 1900 F--for use on ovens, regenerators, and kilns in this tempera ture range. Super Heated Surfaces (500 F, to 1600 F.) Carey Alltemp--Produced from a formula tion of expanded silicas and asbestos fibre. Available in sectional, tri-sectional, seg mental and block forms. ALLTEMP is recommended for insulating high temper ature piping and surfaces such as breech ing, boiler walls, ovens, stills and similar surfaces. It is an ideal insulator for irregular surfaces due to its workability and ease of application. Its exceptionally low shrinkage factor, plus low coefficient of conductivity assures outstanding eco nomical performance when used as a single material or in combination with Carey Super Light 85% Magnesia. Alltemp is water resistant and offers an excellent surface for cements. Now ac cepted and being used by principal boiler manufacturers. Engineering contractors, and industry. Carey Mineral Wool Blankets--(for use up to 1200 F.) A high-quality mineral wool felted to a density of approximately 12 lbs. per cubic foot, and encased between various types of metal fabrics. Furnished in large blankets or sheets 2 ft. wide x standard lengths of 4 ft. or 8 ft., or can be supplied to special lengths, and in thicknesses 1 in. to 6 in. inclusive. These blankets have high thermal efficiency and relatively low cost. They are particularly designed for use in oven walls or on other areas where large-size insulating units are wanted and where mechanical strength or smooth finish is not required. Medium and High Temperature Surfaces (200 F. to 600 F.) Carey Super Light 85% Magnesia--is pre cision molded from a mixture of 85% basic Carbonate of Magnesia and approxi mately 15% asbestos fibre. Super Light has uniform, accurate dimensions--light density and low conductivity "K Factor." It has good strength, low shrinkage and excellent water resistance. Few materials have been so thoroughly tested and found to offer the long efficiency of performance with the economy of application found in Super Light. Carey Asbestos Sponge--For temperatures up to 700 F. constructed of a series of laminated asbestos felts, averaging 30 to 35 layers per inch of thickness. Is recom mended for use on vibrating lines and on installations requiring a structurally tough insulation. Is available in large semicylindrical sections, blocks and sheets. Low and Medium Pressure Steam Sur faces (100 F. to 300 F.) Careycel--Constructed of many layers of "cellized" asbestos sheets. Unusually low thermal conductivity. Furnished in pipe covering sections, sheets and blocks. Carey Air Cell--Course corrugated asbestos structure having four plies of corruga tions per inch of thickness. Carey Excel--A medium corrugated asbestos structure having six plies of corrugations per inch of thickness. Cold Water Pipes Carey Impervo--Comprised from layers of insulating felt cemented together with asphalt saturated organic felts applied to both inner and outer surfaces. Used for insulating chilled and ice water lines to keep water cold and prevent sweating. Proper sealing by use of a suitable vapor barrier is recommended to prevent infil tration of water vapor through the barrier into the insulation causing condensation. Carey Perfecto--Made up of laminations of insulating felt with waterproof felt liner and used to protect against freezing and sweating of cold water pipes. Carey Protecio--Consists of an inner layer of hair felt reinforced by an outer layer of insulating felt and designed to reduce danger of freezing of exposed water pipes. 11 Pipe Size In. 8 10 12 14 16 18 Flat COMBINATION COVERING FOR 700 F. * Indicates Recommended Combinations INNER LAYER CAREY AUTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 1% 1*% 1% v% 1% IH *1H 1H m VA * IH 1H 1H IH *1M 1H 1H *1H IH 1H Outer Layer Thickness inches 2% 2H 3% 1H 2 2H 3 IH 2 2H 3 IH 2 m 3 IH 2 2H 3 IH ,2 2H 3 IH 2 2H 3 Temp. F. at inner Magnesia Surface 441 479 504 515 442 474 500 519 448 479 501 520 468 494 518 540 470 496 520 543 472 499 522 545 482 517 541 560 Canvas Temp. F. with Air at 80 F. 125 118 113 109 128 121 114 111 128 122 116 113 131 124 119 114 132 125 120 116 133 126 121 117 131 125 119 115 B. T. U. Loss Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 286 8,100 245 8,100 223 8,100 205 8,100 341 10,000 301 10,000 268 10,000 241 10,000 384 11,800 339 11,800 305 11,800 277 11,800 426 12,850 384 12,850 341 12,850 300 12,850 477 14,650 419 14,650 377 14,650 348 14,650 518 16,420 457 16,420 415 16,420 377 16,420 91.0 3,870 78.1 3,870 67.5 3,870 59.0 3,870 Percent Eff. % 96.4 96.9 97.2 97.4 96.6 97.0 97.3 97.5 96.7 97.1 97.4 ' 97.6 96.7 97.0 97.3 97.6 96.7 97.1 97,4 97.6 96.8 97.2 97.5 97.7 97,6 98.0 98.3 98.5 1s1 P*ge 6 Pipe Size In* 8 10 12 14 1A COMBINATION COVERING FOR 800 F * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 1!% * 1% 1J% 2% 2% *n% 2% 2% 2% 119% llfl% *1% 2% . 2% 2% 2% IK IK 2 *2 2 2 IK IK 2 *2 2 2 Outer Layer Thickness Inches v% 2% 2H li% 2% IK 2 2K IK 2 2K IK 2 2K IK 2 2K 3 IK 2 IK 2 2K 3 IK 2 IK 2 2K 3 Temp. F. at Inner Magnesia Surface 507 546 577 461 496 504 540 570 452 494 520 511 548 574 467 499 532 555 535 564 482 517 551 571 537 568 485 520 554 575 Canvas Temp. F. with Air at 80 F. 133 125 120 127 121 136 129 120 129 122 118 137 129 123 130 125 119 115 140 132 133 126 121 116 141 133 134 127 122 117 B. T. U. Loss Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 341 11*080 295 11*080 270 11,080 309 11.080 282 11.080 412 13,700 363 13,700 323 13,700 368 13,700 326 13,700 304 13,700 ' 464 16,200 404 16,200 364 16,200 417 16,200 384 16,200 344 16.200 317 16,200 513 17,700 462 17,700 465 17,700 421 17.700 374 17,700 344 17,700 578 20,100 511 20,100 519 20,100 452 20,100 410 20,100 364 20,100 Percent Eff. % 96.9 97.3 97.5 97.2 97.4 96.9 97.3 97.6 97.3 97.6 97.8 97.1 97.5 97.7 97.4 97.6 97.9 98.0 97.1 97.4 97.4 97.6 97.9 98.0 97.1 97.5 97.4 97.7 97.9 98.2 Psge 8 Pipe Size In. 18 Flat COMBINATION COVERING FOR BOO F. * indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness inches 1M ` IH 2 *2 2 2 1M 2 *2 2 2M 2M 2H 2H Outer Layer Thickness Inches 1M 2 1H 2 2H 3 W VA 2 2H 1H 2 2H 3 Temp. F. at Inner Magnesia Surface 539 572 490 524 559 580 550 504 549 581 466 510 547 570 Canvas Temp. F. with Air at 80 F. 142 134 135 128 123 118 140 135 129 123 130 124 120 117 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 632 22,600 551 22,600 570 22,600 495 22,600 453 22,600 400 22,600 110 5,000 96.9 5,000 84.1 5,000 74.3 5,000 86.7 5,000 76.0 5,000 68.0 5,000 61.5 5,000 Percent Eff. % 97.2 97.6 97.5 97.8 98.0 98.2 97.8 98.0 98.3 98.5 98.3 98.5 98.6 98.8 Pace 9 Pipe Size in. Vi % 1 V/4 VA 2 3 4 S COMBINATION COVERING FOR 900 F * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 2*6 ls% 2H m 2% 1*% *H% i*% i'% 1% m 2*6 2*6 2*6 2*J> *1*6 1*6 2*6 2*6 2% 2*6 1% 11% 2% *2% 2% 2*6 2% 2*6 Outer Layer Thickness inches None None None None None 1% iJ% 2% 2*6 m 2% 2% 1J% 2*. 3% 1% 2% l`% 2% 21*6 m 11% 2% 1*% 2% 21% 2% 2i% 3% Temp. F. at Inner Magnesia Surface 438 492 531 567 516 558 589 458 500 532 560 534 576 474 515 554 577 550 591 492 545 575 480 515 542 Canvas Temp. F. with Air at 80 F. 136 142 141 149 141 138 127 120 115 132 123 118 125 118 114 110 134 125 127 121 115 111 136 128 129 122 116 118 114 110 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 147 1.560 169 1.930 182 2.400 216 3.010 208 3,430 201 4,240 179 4,240 164 4,240 162 4.240 222 6,170 200 6,170 184 6,170 208 6,170 190 6,170 178 6,170 150 6,170 260 7,860 231 7,860 239 7,860 220 7,860 198 7,860 187 7,860 297 9,660 268 9,660 273 9,660 243 9,o60 224 9,660 235 9,660 217 9,660 203 9,660 ' Percent Eff. % 90.5 91.2 92.4 92.8 93.9 95.2 95.7 96.1 96.2 96.4 96.7 97.0 96.6 96.9 97.1 97.5 96.7 97.0 96.9 97.2 97.5 97.6 96.9 97.2 97.1 97.4 97.6 97.5 97.7 97.9 Pipe Size In. 6 8 10 12 COMBINATION COVERING FOR 900 F. * indicates Recommended Combinations INNER LAYER CAREY AUTEMP, OUTER LAYER SUPER-LIGHT <5% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness inches m 2& 2% 2% 2% 1% 2Ht *2% 2% 2% 1% 2% *2% 2$& 2% 2% 1?6 2% 2% 2^ 3*6 3% 3 3% Outer layer Thickness Inches l1^ l1^ 2% 1% 2% 3*6 1*% 1% 2*6 2 2H 1H 2 2M 2 2^ 1H 2 1H 2 1H 2 2H 3 Temp. F. at inner Magnesia Surface 364 503 S46 453 498 557 572 517 560 491 525 566 508 556 587 509 540 574 523 560 475 519 435 469 513 540 Canvas Temp. F. with Air at 80 F. 139 131 123 126 120 111 140 134 127 122 118 144 136 129 124 125 120 146 138 132 133 126 126 122 118 115 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe 338 Bare Pip* 11.460 305 11,460 274 11,460 286 11,460 258 11,460 225 11,460 397 14,800 366 14,800 330 14,800 311 14,800 289 14,800 484 18,300 437 18,300 388 18400 354 18400 365 18400 340 18400 544 21,600 498 21,600 457 21,600 460 21,600 420 21,600 420 21,600 394 21,600 360 21,600 333 21,600 Percent Eff. % 97.0 974 97.6 974 97.7 98.0 97.3 974 97.7 97.9 98.0 97.3 97.6 97.8 98.0 98.0 98.1 974 97.7 97.9 97.9 98.0 98.0 984 98.3 98.4 Pege 11 COMBINATION COVERING FOR 900s F. * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 5% MAGNESIA SO9 P. Ambient Air Temperature Pipe Size In. Inner Layer Thickness Inches 2 2 *2M m 14 3 3 3 3 2 *2H VA 16 3 3 3 3 2 *2M 2M 18 3 3 3 3 2 Flat i 2H 3 3 3 Outer Layer Thickness Inches lH 2 lH 2 VA 2 2A 3 1H W 2 1A 2 2A 3 w m 2 w 2 2A 3 m 1M 2 1H 2 2H Temp. F. at Inner Magnesia Surface 543 583 489 530 446 492 529 555 547 492 535 450 496 534 560 552 496 541 455 500 539 565 56* 521 572 486 529 568 Canvas Temp. 4F. with Air at 80 F. 141 134 135 128 130 124 121 117 143 136 129 131 125 122 118 144 137 131 132 126 123 119 142 135 131 132 127 121 B. T. U. loss Per Lin. Ft. Per Hr. Covered Pip* Bar* Pip* 550 23.600 495 23.600 498 23.600 458 23,600 469 23,600 425 23,600 392 23,600 352 23,600 607 26,800 557 26,800 490 26,800 582 26,800 452 26,800 535 26,800 402 26,800 684 30,300 603 30300 552 30,300 566 30,300 495 30300 486 30300 429 30300 115 6,650 102.3 6,650 90.3 6,650 92.2 6,650 82.6 6,650 74.4 6,650 Percent Eff. % 97.7 97.9 97.9 98.1 98.0 983 98.4 98.5 97.7 97.9 983 97.8 98.3 98.0 98.5 97.7 98.0 983 98.1 98.4 98.4 98.6 98.3 98.4 98.6 98.6 98.7 98.9 Pip 12 Pipe Size In. % % 1 V/a VA 2 3 4 5 6 COMBINATION COVERING FOR 1000F. * indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 2*6 l3Xt m 2*6 m 2H 1*6 *2*6 2*6 2% 2% *2*6 2*6 2*6 2*6 2^ *2*fi 2*6 2*6 3*6 2% *2% 2% 3Xz 3& 3`*6 Outer Layer Thickness Inches None None None None None 1*6 1% 1 1* 1* 1 2& 1% 2& 1% 2^ 1% 2*6 1% 1% 2*2 2% l1^ l1^ v% 2Hi 2% m Temp. F. at Inner Magnesia Surface 485 547 442 473 574 509 560 447 502 530 574 480 535 544 494 536 576 449 559 503 555 458 505 400 Canvas Temp. F. with Air at 80 F. 143 150 149 157 149 145 134 132 126 139 131 123 125 119 133 126 127 120 136 129 124 119 124 137 132 126 127 122 123 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 170 2,030 195 2,510 210 3,120 250 3,910 240 4,450 231 5,520 205 5,520 204 5,520 195 5,520 261 8,050 242 8,050 218 8,050 230 8,050 210 8,050 276 10,280 253 10,280 259 10,280 235 10,280 320 12,650 292 12,650 272 12,650 250 12,650 276 12,650 352 15,000 332 15,000 300 15,000 312 15,000 291 15,000 298 15,000 Percent EfF. % 91.6 92.2 93.2 93.6 94.6 95.8 96.3 96.3 96.5 96.7 97.0 97.2 97.1 97.3 97.3 97.5 97.4 97.7 97.4 97.7 97.8 98.0 97.8 97.6 97.7 98.0 97.9 98.0 98.0 Page 13 COMBINATION COVERING FOR 1000 F. * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA SO4 F. Ambient Air Temperature Pipe Size In* * Inner Layer Thickness Inches 2% 2% 2% m 10 12 14 16 1 i 2% *2% 3% 3$6 3>% 2% 2% *3% 3% 3% 3i% 31% 2M *3 3 3M 3M 4 2Y2 *3 3 3H m 4 Outer Layer Thiekness Inches 1!% IX 2 IX 2 IX 2 IX 2 IX IX IX ix 2 2X ix 2 ix IX 2 ix 2 vx IX IX 2 ix 2 ix Temp. F. at Inner Magnesia Surface 574 495 543 450 507 565 567 463 517 431 580 527 481 520 570 442 495 540 495 545 459 510 432 543 500 550 463 514 436 Canvas Temp. F. with Air at 80 F. 141 135 129 130 124 144 131 132 126 127 146 140 132 128 124 130 125 142 136 130 132 127 129 144 137 131 133 128 129 B. T. U. Loss Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 424 19.400 397 19.400 363 19,400 372 19,400 338 19,400 506 24,000 422 24,000 442 24,000 402 24,000 413 24,000 580 28,400 535 28,400 491 28,400 457 28,400 420 28,400 467 28,400 434 28,400 582 31,000 544 31,000 495 31,000 505 31,000 470 31,000 480 31,000 657 35,400 586 35,400 528 35,400 557 35,400 515 35,400 528 35,400 Percent Eff. % 97.8 97.9 98.1 98.0 98.2 97.8 98.2 98.1 98.3 98.2 97.9 98.1 98.3 98.4 98.5 98.4 98.5 98.1 98.2 98.4 98.4 98.5 98.4 98.1 98.3 98.5 98.4 98.5 98.5 o 14 Pipe Size In* 18 Flat COMBINATION COVERING FOR 1000 F, * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches *3 3 sx 4 2H *3 m 4 Outer Layer Thickness Inches 1*4 W 2 IX 2 IX ix ix IX 2 IX Temp. F. at Inner Magnesia Surface 546 500 555 467 518 440 578 537 508 560 475 Canvas Temp. #F. with Air at 80 F. 146 138 132 134 129 130 142 139 134 130 130 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 726 39,800 641 39,800 585 39,800 608 39,800 552 39,800 575 39,800 119 8,700 108 8,700 97.5 8,700 87.5 8,700 90.1 8,700 Percent Eff. % 98.2 98.4 98.5 98.5 98.6 98.5 98.6 98.7 98.9 99.0 99.0 V Page 15 COMBINATION COVERING FOR 1100F. * indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Pip* Six* In. Inner Layer Thiekness Inches 'A y* i VA VA 2 3 4 5 * i i 2*6 1*% 2X m m 2 H 2H 2Vs 2H 2Vs *2% 2% 2% 3*6 3* - 3*6 2*6 *2% 2*6 3% 3% 3*2 2*6 2*6 *3*6 3*6 3*6 2% 3% 3*6 3^*6 3!*6 Outer Layer Thickness Inches None None None None None ix 2*6 l*% 2*6 21*6 11*6 1*% 2*6 11*6 2% 21*6 1% ii*6 2% 11% 256 2!% 1% 2% 11% 2% 2$* li% 11% 2% 1H 2 Temp. F. at Inner Magnesia Surface ... 517 571 475 518 557 560 498 553 453 516 547 586 529 585 479 528 562 540 592 490 540 577 554 506 556 443 497 Canvas Temp. F. with Air at 80 F. 150 158 156 165 156 133 123 125 120 115 137 131 124 126 120 115 140 132 126 126 121 118 135 128 130 124 121 138 132 127 128 123 B. T. U. loss Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 193 2,580 222 3,200 238 3,980 283 5,000 273 5,700 223 7,090 206 7,090 210 7,090 199 7,090 187 7,090 276 10,330 262 10330 241 10330 247 10,330 224 10330 216 10,330 313 13310 295 13310 272 13310 279 13310 259 13310 246 13310 336 16350 310 16350 317 16350 295 16350 276 16350 378 19300 356 19300 329 19300 340 19300 315 19300 Percent Eff. % 92.5 93.0 94.0 94.3 953 96.8 97.1 97.0 973 97.4 97.3 97.5 97.6 97.6 97.8 97.9 97.6 97.7 97.9 97.8 98.0 98.1 97.9 98.0 98.0 983 983 98.0 98.1 983 983 983 Psge 16 Pipe Size In. 8 10 13 14 16 18 COMBINATION COVERING FOR 1100F. * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness inches 2% 3X *3K 3y% 2*% 3% *356 3i% 3% 3>% 2% 356 356 *3% 31% 2H 3 3H 4 4 3 *3M 354 4 4 3 *3H 354 4 4 Outer Layer Thickness inches 1M 134 2 134 2 134 134 2 1H 2 234 134 134 2 134 2 134 134 134 2 134 2 134 134 2 134 2 134 134 2 134 2 Temp. F. at Inner Magnesia Surface 544 498 557 466 517 569 508 565 470 535 580 580 527 571 488 545 592 544 503 550 476 522 550 509 555 482 528 555 514 562 488 535 Canvas Temp. F. with Air at 80* F. 141 135 129 130 125 144 138 132 133 128 123 147 139 134 135 130 150 143 138 136 134 129 144 139 137 135 130 145 140 138 136 131 B. T. L 1. Less Per L n. Ft. Per Hr. Covered Pipe Bare Pipe 453 25,000 424 25,000 388 25,000 397 25,000 372 25,000 532 30,900 506 30,900 461 30,900 476 30,900 430 30,900 402 30,900 610 36,600 569 36,600 521 36,600 533 36,600 492 36,600 667 40,000 619 40,000 580 40,000 555 40,000 540 40,000 513 40,000 678 45,500 628 45,500 624 45,500 586 45,500 549 45,500 740 51,300 693 51,300 684 51,300 660 51,300 604 51300 Percent Eff. % 98.1 98.3 98.4 98.4 98.5 98.2 983 983 98.4 98.6 98.7 98.3 98.4 98.6 98.5 98.6 98.3 98.4 98.5 98.6 98.6 98.7 98.5 98.6 98.6 98.7 98.8 98.5 98.6 98.6 98.7 98.8 Pipe Size In. Flat COMBINATION COVERING FOR 1100F. * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 3 4 4 4H m Outer Layer Thickness Inches W m m 2 ih 2 Temp. F. at Inner Magnesia Surface 590 547 516 578 487 541 Canvas Temp. F. with Air at 80 F. 145 139 135 130 131 128 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 123 11,180 111 11,180 101 11,180 92.6 11,180 94.4 11,180 87.1 11,180 Percent Eff. % 98.9 99.0 99.1 99.2 99.1 99.2 v D.** tp Pipe Size In. '/a % 1 VA VA 3 4 * 6 COMBINATION COVERING FOR 1200F. * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 2% 1*% 2H 1*% 2% * 2y% 2% 2% 3X *2% 3X6 3% 3% 3i% 2% *3% 3% 3i% *3% 3% 4% ' 4% 3% *3i% 31% 4M 4M Outer Layer Thickness Inches None None None None None M li% 2% 1*% 1*% 11% 2% li% 2% 11% 11% 2% li% 2% li% 2% 1M 2 li% 1H 2 IH 2 Temp. F. at Inner Magnesia Surface 563 516 569 463 544 493 562 458 503 580 523 573 479 526 530 547 426 481 555 486 540 455 505 Canvas Temp. F. with Air at 80 F. 157 166 164 174 164 138 131 125 126 136 130 124 125 121 137 131 126 128 122 135 125 126 122 138 133 128 130 124 B. T. U. Loss Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 216 3.240 248 4.040 266 5,000 317 6,300 305 7.200 254 8,920 238 8,920 224 8,920 228 8320 296 13,050 281 13,050 257 13,050 263 13,050 250 13,050 333 16,730 315 16,730 293 16,730 300 16,730 283 16,730 360 20,600 317 20,600 330 20,600 311 20,600 400 24,400 383 24,400 359 24,400 362 24,400 343 24,400 Percent Eff. % 93.3 93.8 94.7 94.9 95.7 97.1 97.3 97.5 97.4 97.7 97.8 98.0 97.9 98.0 98.0 98.1 98.2 98.2 98.3 98.2 98.4 98.4 98.5 98.3 98.4 99.1 98.5 98.6 Page 19 Pipe Size In. 8 10 12 14 16 18 COMBINATION COVERING FOR 1200 F, * Indkotes Recommended Combination* INNER LAYER CAREY AllTEMP, OUTER LAYER SUPER-UGHT 15% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 3X *3% 3H 4% 3% 3*56 3% 4% 4% 3% *3% 3i% 4K 4H 3 4 4 4^ *3M 4 4 4K 4H *3^ 4 4 4H m Outer Layer Thickness inches ix IX 2 IX 2 ix IX 2 IX 2 IX IX 2 IX 2 ix ix ix 2 ix ix ix 2 IX 2 IX ix 2 IX 2 Temp. F. at Inner Magnesia Surface 547 506 566 457 514 554 509 581 488 531 574 534 594 487 552 594 545 520 565 475 551 525 571 481 547 555 529 576 486 552 Canvas Temp. F. with Air at 80 F. 141 136 130 132 127 145 140 133 134 130 146 141 135 137 132 149 144 139 134 136 146 140 135 137 132 147 141 136 138 133 8. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 476 31.600 451 31,600 417 31,600 433 31,600 406 31,600 571 39,100 540 39,100 490 39,100 500 39,100 475 39,100 634 46,400 600 46,400 550 46,400 577 46,400 527 46,400 696 50,700 656 50,700 619 50,700 579 50,700 586 50,700 724 57,700 670 57,700 615 57,700 645 57,700 600 57,700 787 64,900 722 64,900 679 64,900 712 64,900 650 64,900 Percent Eff. % 98.4 98.5 98.6 98.6 98.7 98.5 98.6 98.7 98.7 98.8 98.6 98.7 98.8 98.7 98.8 98.6 98.7 98.7 98.8 98.8 98.7 98.8 98.9 98.8 99.0 98.8 98.9 99.0 98.9 99.0 Pe 20 Pipe Size In. Flat COMBINATION COVERING FOR 1200 F, * Indicates Recommended Combinations INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature Inner Layer Thickness Inches 3M *4 5 5 Outer Layer Thickness Inches 1H IH 1M 1H 2 Temp. F. at Inner Magnesia Surface 599 565 535 515 580 Canvas Temp. F. with Air at 80 F. 146 142 138 134 131 B. T. U. Less Per Lin. Ft. Per Hr. Covered Pipe Bare Pipe 127 14,110 116 14,110 107 14,110 99 14,110 92 14,110 Percent Eff.' % 99.1 99.2 99.2 99.3 99.3 Page 21 DOUBLE LAYER ALLTEMP COVERING For 1300 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Sixe In. v% S/4 1 Thickness Inches Inner Layer Outer Layer 3-11/32 None 3-1/4 None 3-5/32 None . 1V4 ' 1% 2 0s0. 2-31/32 3-11/32 2-1/8 None None 1-1/2 2-1/32 *2-1/16 3 2-9/16 2-1/32 2-1/32 2-9/16 4 2-9/16 2-5/32 2-21/32 2-9/16 5 2-9/16 2-3/32 2-19/32 - 2-17/32 6 2-17/32 2-3/32 2-5/8 2-11/16 8 3-1/8 2-1/2 2-1/2 2-19/32 10 3-1/8 2-1/2 2-1/2 2-5/8 2-1/2 12 3-3/32 2-1/2 3-3/32 3 Canvas Temp. * F. 136 142 148 156 150 149 139 147 139 142 135 145 139 148 142 146 140 150 143 152 147 142 8. T. U. Loss Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 199 .4,020 220 5,020 249 6,240 283 7,850 288 8,940 311 11,140 290 11,140 359 16,260 337 16/260 384 20,810 364 20,810 437 25,620 412 25,620 490 30,410 463 30,410 549 39,420 523 39,420 650 48,950 608 48,950 738 57,900 690 57,900 650 57,900 Percent Eff. % 95.0 95.6 96.0 96.4 96.8 97.2 97.4 97.8 97.9 98.2 98.3 98.3 98.4 98.4 98.5 98.6 98.7 98.7 98.7 98.7 98.8 98.9 DOUBLE LAYER ALLTEMP COVERING For 1300 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Size In. 14 16 18 Flat Thickness Inches Inner Layer Outer Layer * 2-1/2 2-1/2 3 2-1/2 33 2-1/2 2-1/2 *3 2-1/2 33 M/2 3 2-1/2 2-1/2 *3 2-1/2 33 3-1/2 3 2-1/2 2-1/2 *3 2-1/2 33 3-1/2 3 Canvas Temp. F. 156 151 145 159 152 147 143 161 155 148 143 159 152 148 144 8. T. U. Less Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 806 63,480 755 63.480 703 63.480 900 72,400 838 72,400 783 72,400 741 72,400 985 81,380 920 81,380 849 81,380 811 81,380 155 17,630 142 17,630 131 17,630 121 17,630 Percent Eff. % 98.7 98.8 98.9 98.8 98.8 98.9 99.0 98.8 98.9 98.9 99.0 99.1 99.2 99.3 99.3 Page 23 DOUBLE LAYER ALLTEMP COVERING For 1400 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Size In. % % 1 l'/4 1% 2 3 4 5 6 8 10 12 Thickness Inches Inner Layer Outer Layer 3-11/32 None 3-1/4 None 3-5/32 None 2-31/32 None 3-11/32 None *2-1/8 1-1/2 2-1/8 2-1/32 *2-1/16 2-1/32 2-9/16 2-1/32 *2-9/16 2-5/32 2-9/16 2-21/32 * 2-9/16 2-3/32 2-9/16 2-19/32 * 2-17/32 2-3/32 2-17/32 2-5/8 *2-11/16 2-1/2 3-1/8 2-1/2 * 2-19/32 2-1/2 3-1/8 2-1/2 *2-5/8 2-1/2 3-3/32 2-1/2 3-3/32 3 Canvas Temp. * F. 141 148 154 162 156 155 144 153 144 147 140 150 144 153 148 152 145 156 148 158 153 147 B. T. U. Loss Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 220 4,960 245 6,170 277 7,680 316 9,660 320 11,010 346 13,720 323 13,720 400 18,860 376 18,860 428 25,690 406 25,690 488 31,640 459 31,640 545 37,580 . 516 37,580 614 48,740 582 48,740 725 60,540 675 60,540 825 71,640 769 71,640 724 71,640 Percent Eff. Vo 95.6 96.0 96.4 96.7 97.1 97.5 97.6 97.9 98.0 98.3 98.4 98.5 98.5 98.5 98.6 98.7 98.8 98.8 98.9 98.8 98.9 99.0 Page 24 DOUBLE LAYER ALLTEMP COVERING For 1400 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Size In. 14 16 18 Flat Thickness Inches Inner Layer Outer Layer 2-1/2 2-1/2 *3 2-1/2 33 2-1/2 2-1/2 *3 2-1/2 33 3-1/2 3 2-1/2 2-1/2 *3 2-1/2 33 3-1/2 3 2-1/2 2-1/2 *3 2-1/2 33 3-1/2 3 Canvas Temp. F. 162 157 150 166 158 153 148 168 161 154 149 166 158 153 149 6. T. U. Less Per Lineal Ft. Per Hour Covered Pipe Eare Pipe 904 78,560 839 78.560 786 78,560 1.002 89,600 932 89,600 873 89,600 825 89,600 1,100 100,770 1,022 100,770 949 100,770 902 100,770 173 21,780 158 21,780 146 21,780 135 21,780 Percent Eft. % 98.8 98.9 99.0 98.9 99.0 99.0 99.1 99.0 99.0 99.1 99.1 99.2 99.3 99.4 99.4 Page 25 DOUBLE LAYER ALLTEMP COVERING For 1500 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Size In. Vi % 1 IV* IVz 2 4 5 6 8 10 12 1 Thickness Inches Inner Layer Outer Layer 3-11/32 None 3-1/4 None 3-5/32 None 2-31/32 None 3-11/32 None 2-1/8 1-1/2 * 2-1/8 2-1/32 *2-1/16 2-1/32 2-9/16 2-1/32 *2-9/16 2-5/32 2-9/16 2-21/32 * 2-9/16 2-3/32 2-9/16 2-19/32 *2-17/32 2-3/32 2-17/32 2-5/8 *2-11/16 2-1/2 3-1/8 2-1/2 2-19/32 2-1/2 *3-1/8 2-1/2 2-5/8 2-1/2 * 3-3/32 2-1/2 3-3/32 3 00 -M Canvas Temp. 0 F. 147 154 160 169 162 161 150 159 150 153 145 156 149 159 154 151 163 154 164 159 153 B. T. U. Loss Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 241 6,040 271 7,520 305 9,360 349 11,790 353 13,440 382 16,750 356 16,750 441 24,510 415 24,510 473 31,400 448 31,400 539 38,690 506 38,690 600 45,970 570 45,970 678 59,650 641 59,650 800 74,110 742 74,110 912 87,720 848 87,720 799 87,720 Percent Eff. % 96.0 96.4 96.7 97.0 97.4 97.7 97.9 98.2 98.3 98.5 98.6 98.6 98.7 98.7 98.8 98.8 98.9 98.9 99.0 99.0 99.0 99.1 Pa<-- DOUBLE LAYER ALLTEMP COVERING For 1500 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Size In. 14 16 18 Flat Thickness Inches Inner Layer Outer Layer 2-1/2 2-1/2 *3 2-1/2 33 2-1/2 2-1/2 ' 3 2-1/2 *3 3 3-1/2 3 2-1/2 2-1/2 3 2-1/2 *3 3 3-1/2 3 2-1/2 2-1/2 3 2-1/2 *3 3 3-1/2 3 Canvas Temp. * F. 169 162 156 172 164 159 154 175 167 160 155 173 164 159 154 8. T. U. Loss Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 1,002 96,200 923 . 96,200 869 96,200 1,104 109,780 1,026 109,780 963 109,780 909 109,780 1,215 123,440 1,124 123,440 1,050 123,440 993 123,440 191 26,620 175 26,620 161 26,620 149 26,620 Percent EH. % 99.0 99.0 99.1 99.0 99.1 99.1 99.2 99.0 99.1 99.1 99.2 99.3 99.3 99.4 99.4 Pt|e 27 DOUBLE LAYER ALLTEMP COVERING For 1600 F. * Indicates Recommended Thickness 80 F. Ambient Air Temperature Pipe Size In. % % 1 Thickness Inches Inner Layer Outer Layer 3-11/32 None 3-1/4 None 3-5/32 None 1% 2-31/32 None 1% . 3-11/32 None 2-1/8 2 *2-1/8 1-1/2 2-1/32 *2-1/16 3 2-9/16 2-1/32 2-1/32 *2-9/16 4 2-9/16 2-5/32 2-21/32 * 2-9/16 5 2-9/16 2-3/32 2-19/32 * 2-17/32 6 2-17/32 2-3/32 2-5/8 *2-11/16 8 3-1/8 2-1/2 2-1/2 2-19/32 IQ *3-1/8 2-1/2 2-1/2 2-5/8 2-1/2 12 * 3-3/32 2-1/2 3-3/32 3 Canvas Temp. * F. 152 160 167 176 169 167 156 165 156 158 150 162 155 165 160 164 157 169 160 171 165 159 8. T. U. Loss Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 261 7.290 297 9.080 333 1U10 382 14,250 386 16,250 418 20,260 390 20,260 483 29,670 455 29,670 518 38,020 490 38,020 591 46,870 554 46,870 655 55,700 624 55,700 743 72^90 700 72^290 875 89,860 810 89,860 1.000 106,390 927 106,390 874 106,390 Percent EH. % 96.4 96.7 97.0 97.3 97.6 97.9 98.1 98.4 98.5 98.6 98.7 98.7 98.8 98.8 98.9 98.9 99.0 99.0 99.1 99.1 99.1 99.2 Page 28 DOUBLE LAYER ALLTEMP COVERING For 1600 F. * Indicates Recommended Thickness SO4 F. Ambient Air Temperature Ripe Size In. 14 16 18 Flat Thickness Inches Inner Layer Outer layer 2-1/2 2-1/2 3 2-1/2 *3 3 2-1/2 2-1/2 3 2-1/2 *3 3 3-1/2 3 2-1/2 2-1/2 3 2-1/2 *3 3 3-1/2 3 2-1/2 2-1/2 3 2-1/2 *3 3 3-1/2 3 Canvas Temp. F. 176 168 162 179 171 165 159 182 173 166 161 180 171 165 160 B. T. U. Loss Per Lineal Ft. Per Hour Covered Pipe Bare Pipe 1,100 116,690 1,007 116,690 953 116,690 1,206 133,180 1,122 133,180 1,055 133,180 993 133,180 1,330 149,780 1,226 149,780 1,150 149,780 1,085 149,780 210 32^40 192 32,240 176 32^40 163 32,240 Percent Eff. % 99.1 99.2 99.2 99.1 99.2 99.2 99.2 99.1 99.2 99.2 99.3 99.3 99.4 99.5 99.5 Page 29 Vhere to buy { ngineerlng service Carey Industrial Sales Engineers can be easily reached at the District Offices listed below. Call on them for any information you need, or for the name of a Carey-approved contract unit in a major trading area near you. District Offices Atlanta 6, Ga. 251 Armour Drive, N.E. TRinity 4-5793 Boston, Maas. (Cambridge 38) 22 Moulton St. TRowbridge 6-7700 Charlotte 2, N. C. 402 Addison Bldg. 222 S. Church St. FRanklin 7-6502, 7-6503 Chicago District 25th and Warren, Bellwood, 111. AUstin 7-4063 Cincinnati 15, Ohio 316 S. Wayne Ave. VAlley 1-3000 Cleveland 29, Ohio 8551 Brookpark Road FLorida 1-8505 Dee Moines, Iowa 927-28 Insurance Exchange Bldg. CHerry 4-7113 Detroit 38, Mich. 14420 Livernois Ave. TOwnaend 8-2600 Houston 8, Texas 1400 N. Post Oak Road UNderwood 9-3363 Indianapolis 21, Ind. 1432 Kentucky Ave. MElrose 5-1314 Los Angeles 21, Calif. 1760 E. 15th St. Richmond 8-5207 Memphis, Tenn. 1510 Orendo Road JAckson 7-3081 Montreal 9, P.Q. 95 Stinson Blvd. Ville St. Laurent Regent 1-6451 New York 17, N.Y. Lincoln Bldg., 60 E. 42nd St. MUrray Hill 7-1530 Philadelphia 32, Pa. 24th & Sedgley Ave. BAldwin 9-6430 Pittsburgh 20, Pa. 1018 Saw Mill Run Blvd. HEmlock 1-6334 St. Louis 3, Mo. 307 N. Theresa Ave. JEfferson 1-1930 San Francisco 24, Calif. 101 Williams Ave. Mission 8-4400 Seattle 4, Wash. 505 Dexter Horton Bldg. SEneca 2351 ALLTEMP is the newest and latest formulation in the Carey line of Industrial Insulations. Other famous products developed by Carey include Super-Light 85% Magnesia, Hi-Temp No. 19, MW-50 In sulating Cement, MW-1 Insulating and Finishing Cement, Asbestos Cement and a complete line of Bonding, Finishing and Refractory Cements. Carey Engineering Service will help you determine which type of insulation is the best suited and most economical for your particular requirements, and will show you how it can be used to best advantage. Call on Carey any time. after products for industry since 1873 The Philip Carey Mfg. Company Lockiand, Cincinnati 15, Ohio In Canada: The Philip Carey Co., Ltd., Montreal 9, P. Q. LIST PRICES PIPE COVERINGS & BLOCKS industrial insulation The following list prices are to be used for pricing all Carey pipe coverings of corresponding thickness, except that !' thick list pries are to be used for pricing all pipe coverings of I' or less thickness. NOTE: All pipe coverings, blocks and sheets while quoted in terms of following List Prices less discount are actually priced at net unit prices appearing in "Manual of Unit Prices" which are essentially the same as list prices less quoted discount. SPiimpe* 1 Inch Thick Plic--a--p a Feat i Plica par Ijaiaal Fast 2 lack Thkkaaaa Pnca par Liaaai Fact 2H lack Thickaaaa Pnca pat Faat 5 lack Thickaaaa Prica pat Lineal Faat J!: Inch Thickness 4 Inch 4V? Inch 5 Inch Inch * Inch (Ooabia Thickness Thickness Thickness Thickness Thickness Layar) Prica Par Pries Per Prica Par Pries Par Pnce Par Price Per Lineal Lineal Lineal Lineal Lines! Lineal Feet Font Feet Foot Foot Feat inches K v; l* \M IK 2 2H 3 $0.22 *C .24 *C .27 *C .30 *C .33 .36 *C .40 *C .45 *C $0.46 *C .49 *C .52 *C .56 *C .60 *C .64 *C .70 *C .76 *C $0.75 *C .80 *C .85 *C .90 *C .95 < 1.00 *C 1.05 *C 1.15 *C $1.00 *c $1.20 *C 1.05 *C c 1.35 *C 1.10 *C . 1.40 *C 1.15 *C 1 1.45 *C 1.20 *C N 1.55 *C 1.25 *C G 1.65 *C 1.35 *C L 1-75 *C 1.50 *C *. 1.90 *C $1.55 4 $1.95 4 1.7S 4 2.15 4 1.80 4 2.20 4 1.95 4 2.35 4 2.00 4 2.40 4 2.10 4 2.45 4 2.25 4 2.70 4 2.35 4 2.85 4 $2.40 2.55 2.60 2.80 2.90 3.00 3.25 3.40 $2.90 3.10 3.15 3.45 3.50 3.60 3.90 4.00 $3.45 3.65 3.70 4.00 4.05 4.10 4.45 4.60 $4.05 4.20 4.25 4.45 4.65 4.75 5.10 5.25 f 3H 4' .50 *C .60 *C .82 *C .88 *C 1.25 *C 1.35 *C i.ti C i.bs *C 2.60 4 3.15 f 3.70 1.80 *C . 2.20 *C 2.70 4 3.30 4 3.80 4.35 4.45 5.00 5.10 5.65 5.7S 4H 5 .65 *C .70 *C .94 *C 1.00 *C 1.45 *C 1.55 *C 1.95 -C L 2.35 *C 2.95 4 3.50 4 4.10 2.10 *C A 2.50 *C 3.00 4 3.55 4 4.15 4.80 4.85 5.SO 5.55 6.20 6.2S 6 .80 *C 1.10 *C 1.70 *C 2.25 *C V 2.70 *C 3.30 4 3.90 4 4.50 5.30 6.00 6.70 7 1.00 *C 1.20 *C 1.85 *C 2.40 -C E 2.90 *C 3.60 4 4.25 4 4.85 5.75 6.SO 7.35 8 9 I.10 1.20 *C 1.35 *C 1.50 *C 2.00 *C 2.20 *C 2.55 2.80 *C *C RK 3,5 3.40 #C *C 3.85 4.55 4 5.25 4.20 4.90 5.60 6.10 6.65 7.05 7.50 7.85 8.35 ib 1.30 *C 1.65 tC 2.40 JC J.oi tc 3.654E 4.65 5.40 6.15 7.10 8.05 9.00 1! 1.75 JC 1.75 $C 2.55 tC 3.20 tC 3.90+E 4.90 5.70 6.50 7.50 8.50 9.SO 12 1.85 tE 1.85 tE 2.70 tE 3.40 tE 4.I04E 5.15 6.00 t 6.85 7.90 8.90 9.90 14 2.10 tE 2.10 ?E 3.00 tE 3.80 tE 4.60 tE 5.55 t 6.50 t 7.45 8.S5 9.60 10.60 IS 2.25 tE 2.25 tE 3.15 tE 4.00 tE 4.85 tE 5.85 t 6.85 t 7.85 8.95 10.00 11.10 16 2.35 tE 2.35 tE 3.30 tE 4.20 tE 5.10 tE 6.15 t 7.15 t 8.15 9.30 10.45 11.60 17 2.50 tE 2.50 tE 3.45 tE 4.40 tE 5.35 tE 6.45 t 7.50 t 8.50 9.70 10.90 12.05 18 2.60 tE 2.60 tE 3.60 tE 4.60 fE 5.60 tE 6.70 t 7.80 t 8.85 10.10 11.35 12.50 19 2.75 tE 2.75 tE 3.80 tE 4.80 tE 5.80 tE 7.00 t 8.10 t 9.25 10.55 11.75 13.00 20 . 2.85 tE 2.85 tE 4.00 tE 5.00 tE 6.00 tE 7.25 t 8.45 t 9.55 10.85 12.20 13.50 2! 3.00 tE 3.00 tE 4.15 tE 5.20 tE 6.25 tE 7.50 t 8.75 t 9.90 11.25 12.65 13.90 22 3 10 tE 3.10 tE 4.30 tE 5.40 tE 6.50 tE 7.85 t 9.05 t 10 25 11.65 13.05 14.45 "13------- 24 26 3.20 tE 3.30 tE 3.55 tE 3.20 tE 3.30 tE 3.55 tE 4.40 tE 4 50 tE 4.85 tE 5.60 tE 5.75 tE 6.20 tE 6.75 tE 8.05 1 9.35 t 10.70 7.00 tE 8.25 t 9.65 t 11.00 7.50 tE 8.85 t 10.35 t 11.80 12.05 12.45 13.25 13.55 13.90 14.85 15.00 15.35 16.40 27 3.65 tE 3.65 tE 5.05 tE 6.40 tE 7.70 fE 9.15 1 10.60 t 12.05 13.65 15.20 16.65 28 3.75 tE 3.75 tE 5.15 tE 6.65 tE 7.95 tE 9.45 1 11.OS t 12.45 14.05 15.65 17.15 30 4.00 tE 4.00 tE 5.50 fE 6.95 tE 8.40 tE 10.00 1 11.55 t 13.00 14.70 16.40 17.95 \ 32 4.30 tE 4.30 tE 5.90 tE 7.40 tE 9.10 tE 10.50 1 12.10 1 13.85 15.45 17.15 19.00 33 4.40 tE 4.40 tE 6 05 tE 7 (SO fE 9.20 fE 10.70 1 12.45 t 13.9S 15.75 17.60 19.25 APPLYING ONLY TO.FILTER MOLDED $$% MAGNESIA * Sections (semi-cylindrical) 36' long, f Segments (curved blocks) 36' long x approx. 6' wide, t Sections or segments. 41st layer sections or segments, tad layer segments. # 1st layer sections, tad layer sections. 1st layer sections, 2nd layer segments. C Furnished with canvas. O No canvas, but will be furnished without extra charge if ordered. E No canvas. Additional charge if ordered. For pipe sixes over 33' locomotive lagging blocks must be used and prices figured on a square foot basis, See table of quantities and areas at bottom of page 3. APPLYING TO ALL LAMINATED ASBESTOS t FELT PIPE COVERINGS All laminated asbestos and felt pipe coverings are furnished in split cylindrical or semi-cylindrical sections complete with canvas and bands. SHEETS AND BLOCKS The following list prices are to be used for pricing all Carey sheets and blocks of corresponding thickness. TTwikiiw K inch 1 inch inch IK inch Pi in Sqnara Faat $0.2? .30 .34 .38 .42 Thiekaaee 1 K inch IK inch 1K inch 1K inch 2 inch Prica Sqnara Faat $0.45 .49 .53 .57 .60 Thickaaaa 2K inch 2K inch 2H inch 2K inch 2H inch Pnea Sottfe Feot $0.64 .68 .72 .75 .79 Thkkaaaa 2K inch 2K inch 3 inch 3K inch 4 inch 4K inch SqnParraiesFaat $0.83 .87 .90 1.05 1.20 1.35 85% MAGNESIA indussttrriial I List Pricas (par linaar foal) and Thickness Schedules insulaattiioon I COPPER TUBING Pipe Pipe Nominal Size O. D. 1' Thick Th*k List K' .375 IK $.22 X' J00 i!4 .22 "w X' 1' IK' .625 J7S 1.125 1.375 lK l K ihi .22 .24 .27 .30 Pipe Size K' W STANDARD STEEL OR W. I. PIPE Pipe O. D. Nominal Minimum Ncminal 1'Thick Double Layer IK Thick Ncirnmal 2' Thick .540 .675 Th*k List 156 156 s-i -a .22 ThTc 2-.~S. List $.75 .75 ThTc List Th*k List Nominal 2K' Thick ThTc List No:ninal 3"[hick Th*k List K' X9 i' IK' J40 1 t.l/i .22 .75 1% i-i,l$.46 2V6 i.i/^.75 2*56 $1.00 _56_ *31.30 1.050 tt i.t/i .24 .80 ltt uia .49 1*56 4.1/1 JO 2*56 4 1.05 1 1J5 1.315 156 * .27 -an. .85 ltt 4 J2 2K J5 2*56 4 1.10 7 1.40 1.660 tt i JO i% .90 lH 4.1/1 J6 1*56 > .90 2>56 4 1.15 7 1.45 IX' 1.625 JO 2' 2.125 J6 2K' 2.625 % .40 3' 3.125 % .45 IX' 2' 2K' 3' 1.900 2.375 2.875 3.500 l!4 s-i/i J3 _25i_ J5 156 4 J6 -JkL 1.00 156 4.1/1 .40 -2H. 1.05 156 f .45 _25. 1.15 iK 4.1/1 .60 2K ltt i .64 2K 4 IH .70 2H 7 156 4 .76 256 T .95 2K t 1.00 2x t 1.05 2K f 1.15 256 i 1.20 J}i_ 1.25 IK-- 1J5 _Si= 1J0 * 1J5 * 1.65 1.75 1.90 K' 3.625 xMl JO 4' 4.125 .60 <K' 4.625 i% .65 5' 5.125 .70 3K' 4' 4K' 5' 4.000 4.500 5.000 5J63 156 156 < 156 t 156 t .50 _2*JL 1.25 .60 -25JL US .65 2*Kl 1.95 .70 2.10 IN i 156 7 IN S ltt t J2 256 J8 256 .94 256 1.00 256 i s < > 1.25 1J5 1.45 1J5 2>?6 f 1.65 *4- 10 2.05 256 i 1J0 3*^_ 10 2.20 2rXt to 1.95 11 2J5 256 la 2.10 -Iris 11 JJO 6' 6.125 i\k .80 6' r V 9' 6.625 1 % JO _iM= 2.25 IK * 1.10 256 w 1.70 2tt u 2.25 3J6_ 2.70 7.625 09 CQ v 1X to 1.20 256 11 1J5 256 11 2.40 3K- u 2.90 8.625 I 9.625 cue.' S V to g 25 ltt ll 1J5 256 is 2.00 2*56 14 2.55 1K- 3.15 IX tl 1.50 256 14 2.20 2*56 u 2.80 " 3.40 is 10' 10.75 E j 11' 11.75 3 12' 12.75 V u 14' 14.00 hi IS' 15.00 Sl 16' 16.00 (** 17' 17.00 Sg 18' 18.00 5 5 oj L. ^ *>. * III U-J.U = j: ill m 14 i if i i iK it 1.65 256 18 1.75 256 18 1.85 2K IT 2.10 2 ll 2.40 2tt 2J5 2K 2.70 2K 3.00 2K 18 3.05 -&L IT 3.65 it 3.20 u 3.90 u 3.40 _iJ6_ i 4.10 ll 3.80 _4_= *6 4.60 iK 18 IK >* IK to iK n 2.25 2 2J5 2 2.50 2 2.60 2 ll 3.15 2K 18 4.00 4J5 3J0 2K ll 4.20 i. _ MfS.10 3.45 2K is 4.40 MfSJS n 3.60 2K tt$ 4.60 _2__ *4f5.60 Black figures in thickness columns indicate '`prime" solid sections. Red figures in "TH'K" indicate 2 layer assembled sections. Nominal 2' and 2K# thick assemblies can be cemented on request to form one piece. Red figures in ``List" columns indicate outer layer pipe sizes that will make exact fit. Indicator ( ) means nominal 1' thick. ( --) means nominal U4' thick. C---) means nominal 2' thick. Example:--6' pipe size, nominal 3'thick shows -314-which means first layer nominal IK* thick, second layer nominal IK' thick to make total 3-K# thick. tinner layer sections--outer layer segmental blocks. JSegmental blocks. NOTE: Assembled double layer sections will be priced on the basis of the list prices in above tables for such assemblies. Special thicknesses to and 4' can be supplied by combining layers of above prime sections in multiple. SIZES OYER 18" RedNumeral, For diameters over 18', to andincluding 33". segmental blocks approx. 6' wide by 36* long are furnished. indicateblocks ` * `" per section IK'Thick 2' Thick 2K' Thick 3' (2-layer) 19' 20' 21' 22' 23' 24' 26' 27' 28' 30' 32' 33' 1:8 $2.75x 1] $2.85 12 $3.00xj: 33.10 13 $3.20xh $3.30 is $3.55 is $3.65 16 3.80X 4.00 4.15* 4.30 4.40x 4.50 4.85 5.05 $4.00 u $4.30* u $4.40*17 5.50 5.90 i< 6.05Z]9 4.80* 5.00 5.20x 5.40 5.60* 5.75 6.20 6.40 6.65 6.95 7.40 7.60xi9 5.80* 6.00x 6.25 13 6.50* 6.75* 7.00 7.SO 7.70 7.95 8.40 9.10* id 9.20X1O Size 1 ' x 6' x 36' IK' x 6' x 36' IK' * 6' x 36' IX* X 6' X 36' *2 ' x 6' x 36' List Price Per Sq. Ft. $0.30 .38 .45 .53 .60 FLAT BLOCKS Size 2K' x 6' x 36' 2M' x 6' x 36' 3 ' x 6' x 36' 3K' x 6' x 36' 4 ' x 6' x 36' List Price Per Sq. Ft. $0.68 .75 .90 1.05 1.20 Size IK* x 12' x 36' 2 ' x 12' x 36' 2K* x 12' x 36' 3 ' x 12' x 36' 3K' x 12' x 36' 4 ' x 12' x 36' List Price Per Sq. Ft. $0.45 .60 .75 .90 1.05 1.20 LIST PRICES -- ALLTEMP Including thickness tables and working sizes for COMBINATION COVERINGS industrial insulation f" Csss/. MINERAL WOOL PIPE INSULATION UST K1CI PCX LINEAL FOOT--CRATED industrial insulation Tba bold tenia imanartiataly briar the lilt pnea indicate the appmnutt ehipping weight per linal loot. ______________________ _________ ___________________ ____ THICKNESS______________________________________________ _ PIPE SIS IN INCHES NOMINAL 2* 2H* 3* 3H* 4* <H* S' 8* 7* r a* 9* io* 12* 1* THICK 80.70 1.7 .75 24 JB 12 .9S u LOS 25 L15 35 US 32 US 34 L50 35 LOS 42 US 45 2.00 55 2J0 55 1H* THICK 10.90 35 1.W 32 uo 35 uo 35 UO 45 L40 45 150 4.7 LOS 5J US 55 L9S SJ 2.15 75 255 75 2.70 17 2* THICK S1J0 45 L40 55 L50 55 L80 55 L70 55 L85 65 2.00 U 2JS 75 2.20 12 2.50 10 2.75 95 8.00 105 8.20 125 2H* THICK 81.85 62 L75 74 L85 72 1.95 75 2.06 12 2J0 17 2JS 92 250 105 2.70 115 2.96 125 SJ0 125 850 117 3.80 155 2* THICK 8220 9.0 2.30 94 2.45 105 2.00 102 2.75 10.7 2.90 112 8.06 115 3.30 135 355 145 3.80 155 4.10 16.1 4.40 174 4.80 195 OUTSIDE DIAMETER 8350 8100 8100 8420 14* 64 12 117 162 2.80 130 4.00 4.00 16* 74 102 145 110 SJ0 100 4.40 100 18* 15 112 152 205 3.40 100 450 100 20* 62 122 174 212 4.00 440 160 140 34* 105 155 205 265 100 8.80 180 . 7.80 30* 110 165 242 302 Funiiahed in 2-loot length!. Expanded motel lath oo outride. Stnpa of p--wUd matal lath oa tba 85.30 202 180 222 6.30 242 190 262 7.00 302 0.40 372 4* THICK (3.10 115 3.25 142 3.40 110 355 165 8.70 165 3.85 172 4.00 111 4.20 204 450 20.6 450 222 5.10 24.0 5.50 210 8.00 272 8150 300 UO 320 7.00 340 8JO 370 9.50 430 11.20 520 \ jriovs types of Carey Mineral Woof blankets STYLE NO. WO--1-in. (alvmnixad true mah both ridn. For flexibility--oo plaaur baaa. STYLE NO. W1--1-in. galvamaed win mah oa aida ixpamiad maUl lath other aide. For flexibility and plaata baa ana aida. STYLE NO. *02--Metal lath both ridaa. For flexibility and plaata baa both ridaa. STYLE NO. *08--%-in. lib lath (rib In) ana ride 1 In galvanized wire meah other aide. Rigid ooe rida and plaata boa on aide. STYLE NO. tOSA--H-in. rib loth (rib oat) one aide--1-in. galvamaed win mah other aide. Rigid ooe ride and tumiehn a H-in. air apana im plailir baaa. STYLE NO. *04--H-in. rib lath (rib in) one nth metal lath other aide. Rigid one ride and plaata baa both aidn. STYLE NO. *0tA--H-in. rib lath (rib ant) ana rida mr*al lath other nde. Rigid one aide with H-in. air apace and pleater baa ana rida. STYLE_NO.JriA--^-in. rib loth (rib in) ana rida 1-in. galvaniead Rigid one aide and plaata baa ana rida. STYLE NO. S06A--H-in. rib lath (rib ont) ooa aide--1-in. galvaoiad win meah other aide. Rigid one rida and funnahaa a H-in- air apnra no plaata baaa. STYLE NO. Mt--H-in. rib lath (rib in) one -J- --lath othw aide. Rigid one rida and plaata ban both ridaa. TLE NO. tOOA--H-in. rib lath (rib ari) one ride, matal lath othm aide. Rigid one ride with H-in. air apaee and plaata ban one aida. STYLE NO. *08--H-in. rib lath (rib in) both aidn. Rigid both aidn nod p*"*** ban both ridaa. STYLE NO. *00--H-in. rib lath (rib out) one aide--H-in. rib lath (rib in) otha aide. Rigid both aidn end tomiahea H-in- air apace one rida and plaata ban otha ada. LIST PRICES PER SQUARE FOOT The bold figure! immediately below the liet prion indican the approximate ehipping weight pa aquare toot. ____ V STYLE THTC 1V4TH'K 2* TH'K &K 8' THTC T$K 4* TH'K B* TH'K ' THK 300 301 303 303 303A 304 SOLA 300 301A 306 308A 308 309 (0.50 IM 0.55 LS5 0.66 L76 0.55 155 0.55 1.95 0.70 1W 0.70 2.96 0.7D 119 0.70 820 0.85 1.95 0.85 125 0.85 825 0.85 825 (0.55 Sett 0.85 (29 0.70 I.M 0.85 8.46 0.55 9.49 0.75 *55 0.75 855 050 8.85 050 *55 0.05 I.7S 0.96 8.75 0.95 1.99 0.95 *59 (0.60 t.M 0.70 t.75 0.73 189 0.80 180 0.70 t.9fl 0.80 119 0.90 110 190 t.W 0.90 190 LOO 139 LOO 136 LOO 135 LOO 185 (0.70 1*5 0.80 140 055 850 0.90 190 0.80 3.60 0.90 178 0.90 178 1.00 188 LOO 8.88 L10 185 L10 185 L10 4.00 L10 4.90 30.80 8.88 0.90 4.09 0.95 119 LOO 429 0.90 4.W LOO 185 LOO 185 UO 4.45 L10 145 120 455 120 455 1.20 4.80 L20 4.90 10.88 4.49 0.96 458 L03 4.85 LOS 178 0.98 175 LOS 1*6 LOS 180 LIS 6.00 L18 8.00 L28 820 128 820 1.28 825 128 8.28 10.95 100 LOS 115 U0 825 L15 185 1.05 5.85 L15 189 US 550 125 190 125 190 L35 (.70 125 170 1.35 175 1.35 5.75 (1.10 6.26 1.20 135 L25 145 120 055 1.20 185 uo 170 1.80 IN L45 6.80 L45 180 L55 IM 155 8.80 155 0.95 155 (25 $1.25 7.45 L35 7.80 L40 7.79 L45 758 1.35 158 L4S 1.16 L45 7.96 L65 1(6 L65 195 L7S 115 L78 115 L75 9.99 L75 9.99 " Above price! an for Carey Mineral Wool Blanket! in etandard aim aheeta, PIPE COVERING WEIGHTS AND PACKAGING DATA industrial insulation IN POUNDS PER THREE-FOOT SECTION (Net Weight) PIPE SIZES -- INCHES KIND OF COVERING Inches X % ; 1 1* IX 2 2* 3 3% 4 *X 5 6 7 8 9 1 10 1 1= Super Light 85% Magnesia 1 L4 1.3 2.0 1.8 2.3 X7 3.1 3.5 5.2 4.4 6.1 5.0 5.6 Super Light 85% Magnesia 2.9 24 X5 44 XO X7 44 5.9 54 7.0 6.1 8.0 9.0 10.5 11.5 12.7 14.4 16.7 . Vin. Super Light 85% Magnesia DhLLayer 4.5 4.4 5.5 54 7.5 7.1 94 8.5 10.8 10.0 16.6 15.5 17.1 25.0 27.0 29.4 31.3 354 Super Light 85% Magnesia 2 4.5 4.4 5.5 54 74 7.1 94 8.5 10.8 10.0 9.11 11.4 13.0 14.5 16.0 18.6 19.7 23.3 Super Light 85% Magnesia 5.7 8.0 7.8 7.6 10.1 9.7 94 1L5 1X1 13.3 16.6 15.5 17.1 ... 22.0 24.0 25.2 29.7 Super Light 85% Magnesia 8 8.0 10.6 10.5 104 1X1 1X7 124 1X8 18.2 17.4 20.6 19.5 21.7 24.9 27.0 29.4 31.3 354 Alltemp.'.......................... . 1 L5 L7 X3 24 X4 X5 X0 4.6 5.1 X3 64 74 8.6 11.0 12.2 13.4 144 21.1 Alltemp.................................... 1* X2 XI 4.5 4.7 54 5.7 X4 7.3 XI 84 94 10.4 1X9 13.4 1X6 16.3 17.9 21.1 Alltemp.................................... 2 5.9 XI 8.4 7.0 7.6 X6 9.6 10.8 114 1X0 13.7 15.1 16.9 184 204 23.6 25.0 29.1 Alltemp.................................. . DW.1* 11.9 11.8 13.5 1X2 1X9 1X7 16.0 19.8 18.8 2X8 21.6 25.6 2X4 32.1 34.6 38.3 40.7 46.6 Careycel.............................. 1 2.1 24 X4 24 XI X5 XO 44 X6 5.3 5.7 64 74 7.9 8.5 10.8 11.5 12.7 Asbestos Sponge.................. 1 3.8 X3 X2 XO 7.0 74 &0 94 104 11.3 1X0 13.6 15.0 15.7 19.0 19.7 23.8 27.8 Air Cell.................................... 1 1.8 L7 L8 L9 XO 2.4 2.7 XO X3 34 4.2 X9 5.3 6.1 6.9 8.2 8.0 9.6 Air Cell.................................... X L2 L2 14 L4 L6 L9 24 2.5 X7 3.3 3.4 3.8 4.3 44 5.4 6.1 6.6 8.0 Air Cell.................................... X 0.9 L0 14 14 X3 14 L6 L9 24 X3 2.5 X7 XO 3.3 3.8 4.2 4.7 5.6 Impervo................... ............... % 2.1 X2 24 X0 34 X7 44 X7 54 5.7 64 64 74 X9 10.0 11.0 1X0 14.1 Impervo.................................. X L3 L4 L8 L9 24 24 2.9 34 3.6 4.0 44 44 5.7 X3 7.1 7.9 8.7 10.2 Impervo................... ............... DbL% 5.1 5.5 XO X7 74 84 9.0 104 1L0 124 1X2 14.3 1X4 18.3 20.2 22.4 24.5 28.9 Impervo.................................. DhL* 34 3.4 34 44 X6 54 5.8 X7 7.4 XI X9 6.1 114 1X7 1X0 154 174 19.7 Perfecto,,**........................... 1 2.1 X3 24 XO 34 X4 X9 X6 XO X3 54 94 74 8.4 10.7 1X2 13.5 15.6 Perfect..... ............................ X 1.3 L5 14 XI X3 X4 XO X7 XI 44 X9 5.1 X7 X7 7.7 8.6 94 114 Perfecto................................... X 0.8 L0 14 14 L6 L7 L9 X3 24 24 XI X4 X8 4.7 64 6.1 7.0 8.2 Perfect................................... DM. fc 3.4 4.0 4.6 5.0 54 X3 74 X3 9.0 10.1 11.2 12.2 14.2 15.9 17.6 19.7 21.6 25.0 Perfecto.................................. DbL% X3 2.5 XO 34 34 X6 XI 4.9 6.3 X6 64 6.6 7.7 8.9 114 124 14.3 16.2 1 L2 L3 1.7 X3 24 X6 X3 X6 XI X7 5.1 5.6 XI 6.7 74 84 9.6 114 Defender............................ . 1 3.0 i X2 3.4 X7 X4 6.1 5.8 6.5 6.9 7.2 7.6 XO 9.4 104 12.2 13.6 15.0 18.0 F. M. 85% Magnesia weight! same as Alltemp. .. The weight! given in the table* are subject to some variation, but represent averages from which fairly accurate estimates can be made. These weights are not guaranteed. '* Carton Data--Asbestos Blocks and Sheets PIPE COVERINGS (Low Pressure) industrial insulation Cartons (AH Coverings except Asbestos Sponge) Approximate Number of 3 Foot Sections Per Carton Nominal Pipe Size H' 4' i' 14' 2' 2UW 3# 34' 4* 4H' 5' 6' 7' 8' 9' 10' ~ 12' For Standard Steel Pipe Thicknesses W 4' 1' l 4' i4' 2' 60 55 35 28 18 15 9 42 30 23 15 12 8 30 24 18 12 11 7 24 20 15 12 11 6 20 15 12 986 15 12 11 665 11 9 8 6 6 4 9 8 6 5 54 g 6 6 444 6 5 5 444 s 5 4 333 4 4 4 2 23 4 4 4 2 23 4 4 3* 2 2 2 3 2 2 222 2 2 2 2 1* 2 2t 1 1* 1* Nominal For Copper Tubing --Thickness Copper O.D.of TubeSize Copper 4' K' 1' 14' Tube % 4' 77 4' 73 60 42 54 35 20 18 4' 4' 54 42 30 15 i' 14' so 35 28 15 i vs 1*4' 40 30 23 12 l 4' l4' 30 24 18 12 2' 24' 24 18 15 9 24' 2*4' 18 15 12 7 3' 34' 15 12 9 6 34' 34' 12 9 8 6 4' 44' 8 6 6 4 S' 54' 6 5 4 3 6' 64' 7 4 4 8' 84' 8 4 3 Carton Size: 134' * 194' * 36' Carton Weighs: 5 lbs. 36' Car holds 360 cartons 40' Car holds 450 cartons 40' x 10 Car holds 550 Cartons 50' Car holds 670 cartons Carton Si*e: 18' x 18' x 37' Carton Weighs: 6 lbs. f . 1 see. Impervo, Perfecto, Proteeto * . 2 see. Impervo, Perfecto, Proteeto Cartons (Asbestos Sponge Only) Approximate Number of 3 Foot Sections Per Carton Tominal ipe Size 4' 4' l' 14' 14' 2' 24' 3' 34' 4' 44' 5' 6' 7' 8' 9' 10' 12' Thickness 1' 14' 15* 8' 12* 6* 12* 6* 9* 6* 8* 5* 6* 4* 5* 6 86 6S 64 54 44 42 42 23 22 21 21 2' 5* 4* 4* 4* 3* 5 4 3 3 3 2 2 2 2 2 1 1 I 3* 5 4 4 4 4 4 3 2 2 2 2 2 2 1 1 1 1 1 Carton Size 134' * 194' x 36' Carton Weighs: 5 lbs. Half Carton Size 104' * 134' x 36' Carton Weighs: 24 lbs. 36' Car bolds 360 cartons 40' Car bolds 450 cartons 40' z 10 Car bolds 550 cartons SO' Car holds 670 cartons . PACKAGING 85% MAGNESIA and ALLTEMP industrial insulation PACKAGING AH tires and thidoaesses of 85% Magnesia and Alltemp pipe coverings and bloda are packed in cartons for domestic shipment as shown in the following tables: INSULATION PACKAGING Pip* Sica 1/4 3/S MOW. 1* THICK 5m Pi Pk Ca Type Gcaa* Vi. Sap** Allttap Licks F.P 36 32 36 52 64 51 76 73 NOW. 1-1/2* THICK Sac Pf Cia Pkp Typa Gcaa* Vi. *Pt AJUaap LUbl F.P. 25 53 23 53 61 79 60 7* NOW. 1* THICK Sac Pk. Oiaa* Vi. Pat Ct* Typa Sapat AlMaaay LUbi F.P. 16 33 16 55 79 76 99 96 NOW. 2-1/2* THICK Sac Oiaa Vi. Pat Ct* Typa Sapat Litbt Alli.ap F.P. 31 33 31 37 71 71 NOW. 3* THICK Sac Pat Ci* Pk|. Typ* Oraa* *. I Sapat Ailic--p | Li.br F.P. 9 35 ?S 9 35 7S 102 102 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 4-1/2 5 6 7 S 9 10 11 12 14 15 16 17 IS 36 52 36 32 23 S3 25 55 25 53 16 33 16 55 9 31 9 35 9 55 sS 39 59 4 32 -- ---_ -__ ---- 57 73 25 55 79 100 34 6S 23 55 77 96 16 55 16 55 60 79 97 94 33 77 35 77 35 70 16 S3 62 77 50 63 16 55 74 *9 63 SI 16 55 71 S3 30 39 9 31 41 59 37 67 9 35 64 64 37 49 9 55 60 75 9 51 9 31 33 53 63 68 9 S3 9 35 7> 72 94 91 I 59 S 59 61 74 101 97 55 76 55 76 59 66 39 63 32 33 52 32 34 67 S 59 67 SS 47 5* S 59 63 SO 4 52 4 32 49 46 St 36 34 64 54 61 56 70 4 52 41 S3 47 59 4 32 38 44 4 34 4 34 53 53 71 64 36 74 56 7P 21 34 4 54 43 34 - - 4 56 49 62 4 56 2 37 39 34 76 49 37 40 36 43 2 57 21 37 - - 2 31 31 39 2 36 2 36 36 43 46 33 36 30 39 34 - - 2 36 34 46 - - 2 39 37 49 2 59 1 31 43 27 36 33 31 30 31 33 _ _ 1 31 22 27 -- 1 31 22 - 1 31 1 33 29 30 - 33 36 34 36 _ - 1 53 24 - -- 1 34 27 - 1 54 1 33 31 33 - 33 40 36 41 - - 1 33 27 - . 1 36 36 - - 41 - - 1 36 30 -- 1 - 33 - -- -- 101 1 59 90 99 6 59 90 96 6 59 90 96 59 86 112 4 52 58 106 4 52 56 69 4 34 67 65 4 54 67 79 4 36 78 76 4 36 77 94 2 37 46 86 2 57 44 30 2 36 49 56 2 58 34 63 2 39 59 69 1 31 36 36 1 31 37 - 1 33 39 - 1 54 44 - 1 35 45 - 1 36 4* - -- - - -- - -- ---- - Pip* Caaatia* Can**a--Typa* aarf Siaa* (Oaai4* P^aaiit--) .. -S.f-.hK Nw 51-17-1/2** 17*1/5* *36-7/** -6J35 N*.52-18** ll*i 36-7/S* .*.914 N*. 55- 1*3/8* s 16-3/8* * J4-7/S* . 7.403 W* 34--19-7/8* s 19*7/1* * 36*7/8* *8^30 A*. 35-2>5/8* t 20-3/1* t 367/8* - 9.078 N*. 36-22** 22* a Sfr-7/6 ' .10.52* Na. 37-24-1/t* 112-l/S* s 3*>7/S* 6J42 N*. 3S --2P3/S* s 14*1/2* * 36-7/8* * 8.857 N*. 39-31-1/4*8 15-5/4** 36-7/8* -10.303 N*. 60-22-3/8** 16-1/8* 36-7/8* *7.699 lit 117 114 114 7) 61 66 17 105 97 59 57 63 72 0 44 - - -- BLOCK PACKAGING DATA - FLAT BLOCKS Super-Light 85% Magneslo Filter Press 85% Magnesia, Alltemp and HI-Temp No. 19 Block Size flocks Per Carton Croat Weight Block Size Blocks Per Carton ___________ Gross Weight Filter All- Hi- Carton Press temp Temp 1 " x 6" z 36" lk" z 6" z 36" iH" z 6" z 36" 2 " z 6" z 36" 2H" z 6" x 36" 3 " z 6" z 36" 36 28 24 18 14 12 53 SlH S3 53 siH 53 Super-Light Flat Blocks sacked in Carton Type 40 with outside size of 12k" * 18H* z 36H"- Cu. Ft. 5.117 I " z 6" z 36" lk" z 6" z 36" 1H" z 6" z 36" 2 " z 6" z 36" 2H" z 6" z 36" 3 " Z 6" z 36" 24 20 16 12 10 8 6" x 36" 6" z 36" 6 6 Carton Size (outside dimension) CN-1 CN-5 CN-1 CN-1 CN-S CN-1 CN-1 CN-1 51 53 51 51 53 51 51 51 60 63 60 60 63 60 60 60 No. CN-1 12k" x 12K' z 37". No. CN-5 - 12k" x 13X' x37". 87 93 87 87 93 87 87 87 3.481 cu. ft. 3.583 cu. ft. BLOCK PACKAGING DATA - SEGMENTAL BLOCKS Super-Light 85% Magnesia Filter Press 85% Magnesia, Alltemp and Ht-Temp No* 19 Block Size Blocks Per Carton Grots Weight Nominal Pipe Size No. of Segments per Section AB Thicknesses No. of Blocks per Carton Thickness \\j"________ 2" 2H" 3" 1H" * 6" z 36" 2 " z 6" z 36" 2M" z 6" z 36" 24 18 14 62 64 64 Super-Light Segmental Blocks packed in Carton Type 47 with outside size of 14k" * 19k" * 36k". Cu. Ft. - 6.315 12" 14" 16" 18" 20" 22" 24" 26" 28" 30# Carton Size 8 14 10 8 9 16 12 8 10 16 12 8 11 16 12 12 16 12 13 16 12 15 16 12 16 16 12 17 16 12 18 16 12 12" to 18" md. packed in CN*5 (size shown above) ?0" rwj t ^ LaraaBiHM j fa PACKAGING TRI-SECTIONAL ALLTEMP PIPE COVERING industrial insulation CKAGING Tri-Sectional Pipe Covering is packed in cartons for domestic shipment as shown in the following table: I fe PIPE DIMENSIONS FITTINGS AND FLANGES industrial! insulation Standard dimensions; wrought iron and steel^steam, gas and water pipe Nominal internal INCHES 16 H * 1 1% 116 2 216 3 316 4 416 s 6 7 9 10 11 u ttlAMETEK Actual asternal INCHES .405 .54 .875 .84 1.0S 1.315 2.66 1.9 2.37$ 2.875 3.5 4.0 4.5 5.0 1563 6.625 7.625 8.625 9.625 10.75 11.75 12.75 14.0 16.0 110 20.0 22.0 24.0 Actoaf internal INCHES .269 .364 .493 .622 .824 1.049 148 1.610 2.067 2.469 3.068 3.548 4.026 4.506 5.047 6.065 7.023 7.981 1941 10.020 11. 12. 13.25 15.25 1745 1945 21.25 234S NOMINAL THICKNESS INCHES .068 .088 .091 .109 .113 .133 .24 .145 .154 .203 .216 .226 437 2*7 2S1 48 401 .322 .342 465 475 475 475 .375 475 475 CIRCUMFERENCE TRILNSVERSE AJtEA jExterna! . Internal INCHES 1.272 1.696 2.121 2.639 3.299 4.131 5.215 S.969 7.461 9.032 10.995 12.566 14.137 1S.708 17.477 20.813 23.955 27.096 30.238 33.772 36.914 40.055 43.982 50.266 56.549 62.832 69.115 75498 INCHES .845 1.144 1.549 1.954 2.589 3.296 4.333 5.058 6.494 7.757 9.638 11.146 12.648 24.156 15.856 29.054 22.063 "21073 28.089 31.479 34.551 37.7 41.626 47.909 54.193 60.476 66.759 73.042 Extaraal Intarnal M*ul SO. INCHES SO. INCHES SO. INCHES .129 .057 .0717 .229 .204 .1249 .358 .191 .167 .554 .304 .250 .966 1458 .533 .3327 .864 .494 2.164 2.496 .668 2435 2436 .799 4.43 3.356 1.074 6.492 4.788 1.704 9.621 7493 2428 12.566 9487 2.679' 15.904 12.73 1174 19.635 15.947 1688 24.306 20.006 4.300 34.472 28.888 5484 45.664 36.738 6.926 58.426 50.027 8.399 72.76 62.766 9.974 90.763 78.855 11.908 108.434 95.033 13.401 127.677 113.098 14479 153.938 201.062 137.887 182-655 254.470 239.706 314.159 291.040 380.143 3S4.6S7 452490 424.558 LENGTH PIPE PER SQUAR t FOOT External surface Internal surface FEET 9.431 7.07S 5.657 4.547 3.637 2.904 2.301 101 1.608 2428 1.091 .955 .849 .763 .686 .577 .501 .442 .396 455 .325 499 .273 439 412 .191 .174 .259 FEET 14.199 10.49 7.747 6.141 4.635 1641 1768 1372 1.848 1.547 1445 1.077 .949 447 .756 .63 444 .478 .427 481 447 419 488 450 421 .198 .180 .164 LENGTH OF PIPE Contammi 1 cu-toot FEET 2533. 1383.3 754.3 473.9 270. 166.6 964S 70.73 4191 30.07 19.47 14.57 11.31 9.03 7.198 4.91 172 1878 2494 1.826 1.51 147 NWOEMIGINHATL PER FOOT POUNDS 444 .42 .567 .850 1.115 1.678 12*4 1717 1609 5.793 7.575 9.001 10.665 12.538 14.671 18.762 23.271 21544 33.907 40.483 45.028 41985 Asbestos cement for standard fittings THIf TIHC fives tht approximate number of pounds of asbestos cement which will cover standard scrawod flttinfs and flanfes 1 in. thick- It is based upon asbestos cement havtnf a covennt capacity of IS sq. ft l in. thick per 100-lb. bat. H 85% Mapmia cement is used, one-fourth the amount wilt be repaired. Where flttinfs era covered flush with adjacent 1-in. thick pipe covennt only approiimateiy tt-in. thickness required and consequently one-half the amount specified in this table. for flanted flttinfs Spire the amount required for screwed fitimfs and in addition the amount required for the number of sets of Denies on each flanted Attinf. Where sleeves of sectional ceverint or blocks are used around the outer surface of flanees only one-third the amount of cament specified in the table will ba needed for fillmi cracks and fillinf m space between such sleeve and the outer surface of l-m. thick pipe covering For 45-defree ells approsimateiy one-haIf the amount specified for 90-decree ells will oe required. For ion; radius His approximately two times the amount specified for 90-detree efls will b required. NOMINAL PIPE SIZE. INCHES K. *. and 1.., 1%. 116. and 2. Z'A end 3........ 3W and 4........ 4ft and 5___ : 6............. 7........................ 8............. 9...................... 10............ 12.................... POUNDS ASBESTOS CEMENT * ELLS VALVES ANO TEES CROSSES ONE PA FLANGE 2.0 15 17 4.5 3.5 44 4.7 11 6.0 75 10 19 9.0 113 110 111 115 15.6 117 14.1 15.0 118 20.0 114 115 23.1 24.3 19.0 19.5 244 26J) 210 24.0 X.0 310 26.0 29.0 311 319 275 37.5 47.0 510 38.0 Fittings and Flanges--Insulation Areas PIPE SIZE INCHES 2ft 3 3* 4 4ft i .6 7 9 10 12 14 16 18 20 22 24 26 28 X FURMO FITTIMS AVERAGE SO, FT. AREA OF SO. FT. CEMENT METAL SURFACE USED SOLID 0.7 15 05 U 1.0 15 14 17 15 1.9 1.7 11 24 16 2.7 34 34 35 4.0 45 45 55 64 18 13 9.0 17 105 110 135 145 155 174 11$ 21.0 224 24.0 25.0 27.0 285 305 315 PIPE SIZE INCHES 2* 3 3* 4 4* 5 6 7 8 9 10 12 24 16 18 X 22 24 26 28 X ruNtcs SQUARE FOOT 8LOCKS 25 14 1.4 1.6 1.7 U 11 14 17 11 3J 4.4 4.8 10 18 7.7 17 105 115 135 145 SO. FT. CEMENT A THICK OVER m* SLOCKS 14 16 17 19 3.0 34 35 45 45 4.8 54 17 7.0 95 110 11.0 112 114 14.7 110 110 tC MCTAl IAEA to sacure tret of Mocks. For area of 16-in. cament over 1-io. Mock use 13316*01 metal area. For area of 16-in. cement ever 116-in. Mock use 140* of metal area. For am of ft-ia. cement aver 2-in. Mock use 150* of motel am. The second column under flttinfs indicates the square-foot area of Mocks required to caver them while the third column shows the square-foot area of comont usod solid. TNI SMOKO WtOMN VN0CI FlANStt indicafts the sqssre-foot ares of Mock insulation required to cover them, while the third column shows the square-foot area el cement 16 in, thick nod over lV6*in. thick blocks. H| UTg"! PROPERTIES OF SATURATED STEAM STANDARD AREA TABLES industrial insulation HEAT UNITS NEAT OF TOTAL PRESSURE TEMPERATURE IN LIQUIO IN POUNOS IN DEGREES ABOVE persq. men F. 32* F. VAPORIZATION HEAT UNITS (LATENT IN STEAM HEAT) ABOVE 32* F. DENSITY POUNDS PER CU. FOOT SP. VOL CU. FOOT PER POUN0 STEAM $ 10 14.7 40 SO CO 70 SO 0 100 no 120 rm "" ISO ISO 170 ISO ISO 200 22$ 2S0 27$ 300 38 290 37$ 400 42$ 450 47$ 900 " $ v S50 S7S too <2$ 490 67$ 700 16238 1*122 212.0 221.0 2503 2*73 2S1.0 292.7 3023 3123 3203 3273 3344 3413 347.4 3934 ' 398.5 3*3.6 36S3 373.1 3773 3S13 3S13 401.1 4093 4173 424.7 4313 438.4 4444 450.7 45*3 4613 4*7.3 4723 4773 4*2.0 4*6.6 4903 4953 4993 501.4 mi 161.1 186.0 196.1 2183 236.1 250.1 2611 2716 2*10 2903 2913 3053 3113 3116 324.6 3303 3316 3417 345.6 3514 3543 3610 3712 3S4.0 3917 4003 4012 411 421 429. 431 441 441 454. 459. 464. 469. 474. 471 4S4. 4*7. 10013 9H0 9714 MOO 9411 9333 9233 9143 9073 9003 m3 S810 8H5 8773 8713 867.6 8*33 SSU 8917 8503 8463 8433 SSU 8263 Bill *U3 8043 7973 791 781 781 774. 7H 761 757. 791. 741 741. 731 721 717. 711. 11315 11411 11914 11563 11619 110.4 11733 11710 11793 11823 1184.4 118*3 11883 11816 11913 11923 11914 11X3 11*5.4 11914 11973 11911 11918 12013 12023 1204.1 12011 12011 1207. 1201 1201 1201 120. mi 1211 mi mi mi 1201 1201 1191 1191 101364 102606 103732 10728 1003 1117$ 11394 11612 11829 12044 12298 03472 03*83 0307 13107 13320 13929 03738 13948 141S7 1437 140 0341 1913 0345 030 1790 031 10 191 036 132 131 U4 130 136 132 137 1.41 1.47 132 733 314 218 211 117 103 83 73 63 S3 43 4.4 43 17 IS 33 10 23 23 23 2.4 23 11 13 1.7 13 13 13 13 13 LI 13 13 19 03 IS 18 18 17 17 C.7 17 Absolut* prtswn=|tui* prosur*+14J. THE STEAM TASK ABOVE is reprinted f* port from Marks and Davis, Tibia* and Disframs of the Thermal Proeortias of Satereted sod Seperheated Steam" by permasoe of tba pfbhtJwrs Mtssrs. UaCBNfc Grten A Co. T1SUATIMKT Araat tor Flat, Conrad and Taparad Mocks S in. widt. For 34a. wida blocks multiply i' shown bp 03. For 9-ia. *da Mocks mettiply area shown by 13. For 124r. wide Mocks multiply area shown by 2.0. ftatain sH daamals in all eases. For B/oefcs and Lagging FLAT BLOOM THICKNESS CfRVEO 810*1--OVER 16H-IN. RADIUS* LESS THAN m INCHES OVER m TO 2 INCHES 2 INCHES INCHES INCLUSIVE LENGTH BLOCK AREA BLOCK AREA BLOCK AREA SLOCK AREA BLOCK INCHES SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET * 302 302 Mi 302 302 302 302 ft 30 30 30 30 ft 310 310 312 38 % 316 316 316 316 ft 3 322 38 38 ft 326 328 3a 38 96 332 332 334 334 ft 336 338 338 30 t 342 344 344 364 2 304 30 30 30 3 .126 332 48 434 4 30 4ft 47* 47B $ 30 320 38 324 6 390 364 30 30 1 392 30 310 312 8 334 30 394 30 t 376 394 30 302 10 411 338 342 30 11 AH 382 30 38 12 30 326 38 30 13 342 370 37* 38 14 384 414 30 38 15 32* 30 364 3a 16 364 402 40 J16 17 30 .70 48 40 IS 350 40 40 30 19 .792 332 342 30 a 334 376 30 30 21 376 J3Q 38 22 316 30 374 30 S 398 1.00 1318 138 24 1.00 1392. 1362 1372 a 1.012 130 1.10 141* a 1384 1.10 148 L18 ua27 L164 L10 130 a 1.10 13 130 138 a 130 1372 130 130 a 1390 1316 138 1342 31 1392 130 1372 130 32 1334 1.402 L416 L430 33 1379 1.416 1.40 130 138 a 1.40 1334 130 130 a 130 1371 13M 1310 37 1342 L622 138 1354 1.60 1.68 LBt a 1326 1410 1426 1.744 uaa 130 1454 140 41 130 140 131$ 138 42 1350 1342 130 1477 PACKAGING DATA industrial insulation j freight tables /innate freight in per cent of list price for any rate of freight multiply the percentage given .e freight rate in dollars: example, to determine the cost of Magnesia covering when the freight rate is 35c per cwt.: .0 % X $0.35 = 1.75 % of the list price. FOLLOWING TABLE shows the approximate freight cost for various coverings in per cent of list based on $1.00 per cwt. freight rate. ,o Magnesia Blocks................................... 6.0% % Magnesia Covering............................... 5.0% \lltemp Covering........................................... 5.0% Alltemp Blocks............................................... 6.0% Air Cell Covering (2-ply)............................. 1.9% Air Cell Covering (3-ply)............................. 2.8% Air Cell Covering (4-ply)................................ 3.5% Carocel Covering (%' th.)........................... 2.9% Carocel Covering (%' th.)........................... 5.0% Carocel Covering (1* th.)................................6.0% Hi-Temp No. 19 Blocks................................. 8.5% J Tempchek Pipe Covering............................. 7.5% ' Impervo Covering th.)........................... 3.3% f Impervo Covering (%' th.)..............................4.6% f Impervo Covering (1' th.)............................. 6.3% ^ Multi-Ply Covering (l'th.)........................... 8.5% r Perfecto Covering (%' th.)......................... 3.0% Perfecto Covering ($4' th.)......................... 4.3% l Perfecto Covering (1* th.)............................. 5.9% : Protecto Covering (1* th.)......................... 5.0% L Asbesfos Paper weights and measurements WEIGHT PER ONE POUND WEIGHT OP 100 SQUARE FEET WILL COVER ONE SQUARE FOOT POUNDS SQUARE FEET POUND THEORETICAL GAUGE 65 LBS. PER CU. FT. INCHES AVERAGE ACTUAL GAUGE INCHES FRACTIONAL SQUARE FEET THICKNESS PER 100 POUNDS 6 16.66 7 14.28 8 12.50 9 11.11 10 10.00 12 8.33 14 7.14 16 6.25 20 5.00 24 4.16 32 3.12 48 2.08 64 1.56 .06 .07 .08 .09 .10 .12 .14 .16 .20 JU .32 .48 .64 .0109 .0127 .0145 .0163 .0181 .0218 .0254 .0290 .0363 .0435 .0581 .0872 .1162 .015 .017 .019 .021 .022 .027 .029 .032 .039 .046 .060 .089 , .125 ... 1/64 ... . ... ... 1/32 ... 3/64 1/16 3/32 1/8 1666 1428 1250 1111 1000 833 714 623 500 416 312 208 156