Document 5DLqGaoDa8dZOvMGJ001jJJ0z
-- A?? ?-''
11
\ f - l ^11 l
TABLE OF CONTENTS
ETndustriai linsulation
PRODUCT
PAGE
Air Cell Pipe Covering & Block.......................... 17
Alltemp Pipe Covering...................................... 5-6
Alltemp Block.................................................... 7-8
Asbestos Millboard.............................................. 47
Asbestos Paper & Rollboard.............................. 45
Asbestos Sheets & Panels
Asphalt Plyboard.......................................... 49
Careystone Corrugated...................................49
Firefoil Board................................................ 50
Industrial A-C Board.................................... 49
Thermo-Bord ................................................ 49
Asbestos Sponge Pipe & Block Insulation.......... 21
B.T.U. Cement.................................................... 42
Careycel Pipe & Block Insulation.................. 15-16
Careytemp Pipe & Block Insulation.................4-4A
Cements
Insulating & Finishing.................................. 37
Bonding & Refractory.................................. 38
Cork-Cote Mastic................................................ 40
Corrugated Asbestos Paper................................ 46
Defendex Pipe & Board Insulation...................... 19
PRODUCT
PAGE
Fireclad Jacketing.............................................. 43
Flexible Tubing Insulation.......... ....................... 22
Hair Felt Insulation............................................ 31
Hi-Temp #19 Block............................................ 9
Insulation Emulsions.......................................... 39
Insulation Seal.................................................... 41
Mineral Wool Industrial Blanket...................... 27
Mineral Wool Industrial Pipe Insulation.......... 29
MW-50 Insulating Cement................................ 33
MW-One Insulating Cement........................ 35-36
Spun Mineral Wool Duct Insulation...............51-52
Superbo Pipe Covering...................................14-14A
Super-Light 85% Magnesia Pipe Covering.... 1-2
Super-Light 85% Magnesia Block...................... 3
Thermoglas Pipe Covering............................ 23-24
Thermoglas R/F Insulation.......................... 25-26
Weatherproof Jacketing Materials.................... 44
Woolfelt Pipe Covering
Ferfecto.......................................................... 11
Impervo.......................................................... 12
Protecto.......................................................... 13
f \
SUPER-LIGHT 85% MAGNESIA PIPE COVERING
1 me -
industrial
insulation
Conductivity (kV-
At 100 F.r-.34 200 F.--.37 400 F.--.43
Moisture Absorption (volume)-- After 6 hours exposure in atmosphere of 120 F. and 90% relative humidity-- 0.9%.
TABLE OF RECOMMENDED THICKNESSES
Pipe Sites
Temperature Range-- F
100 to 200 201 to 300 301 to 400 401 to 500 501 to 600
H" to Mi"
1" 1" 1" l-X" 2"
2" to 3-H"
1" 1" 1-K" 1-S" 2"
4" to e'
i" l-K" 2" 2" 2-K"
7" to 10"
1-K" 1-H" 2-Y," 2-M" 3"
12" & Larger
1-M" o* 2-K" 3" 3"
Super-Light "Nesting O.D." pipe sec tions, for temperatures from 100 F. to 600 F.
DESCRIPTION
Super-Light 85% Magnesia is composed of not less than 85% basic hydrated carbonate of magnesia, and 10% to 15% specially selected and prepared long asbestos fibers.
Government Specifications: Super-Light 85% Magnesia meets these government specifications when orders specify this requirement.
Federal HH-M-61a--Pipe Covering, Blocks and Cement (when ordered, special 3.5 canvas will be supplied to meet certain Federal Specifications.)
M1L-P-2781B--Grade 1, Class b--Pipe Covering (Super-Light). Test Reference EES 1CCT411.
Navy 21Yc--Pipe Covering and Blocks
Navy 32P10B--Cement
AMSC 35-Type H2
FEATURES
Super-Light 85% Magnesia is strong, moisture resistant, shock resistant and smooth finished. It is a material with low conductivity and high dimensional stability. Super-Light Magnesia has no tendency to induce corrosion on metal surfaces to which it is applied as in sulation. Sections will not disintegrate, crack or crumble under normal service conditions...can be removed and re applied when necessary. Excellent workability makes Super-Light easy and economical to apply.
USES
Super-Light 85% Magnesia pipe covering is a practical, efficient insulation for almost every kind of hot-pipe application. It can be used directly on pipes operating at temperatures up to 600 F., or it can be used as an outer layer over Carey Alltemp where temperatures range from 600 F. to 1600 F.
SPECIFICATIONS
Density--Approximately 10-11 lbs. per cu. ft.
Shrinkage-- 0.5% at 500 F.
Boiler feed pump room of the Arapboe Station, Public Service Co. of Colorado in Denver. Feed water discharge lines
and recirculating lines are insulated with 2" thick Carey 85% magnesia,
Carey Industrial Insulation
' ''PLICATION
anal pipe coverings are held in pjace by cementing the canvas laps with cold water paste, along lateral and abutting joints. As additional secure* ment, metal bands can be applied ap proximately 18" apart on butt joints and in the center o{ the section.
Fittings up to 4" are usually insulated with 85% Magnesia Cement. Larger fittings are usually insulated with small pieces of Super-Light 85% Magnesia Block cemented with fibrous adhesive or secured with wires. Super-Light 85% Magnesia Cement or Carey No. 303 Asbestos Cement should be used to fill cracks at joints and create a smooth surface.
steam line and turbine central
-s at Jamestown, N.Y. power plant
are insulated with Carey Super-Light
85% magnesia.
^
Super-Light 85% Magnesia Pipe Covering
s
v..
SUPER-LIGHT 85% MAGNESIA BLOCK
(industrial (insulation
Conductivity (k) --
At 100 F.--.33 200 F.--.36 400 F.--.43
Moisture Absorption (volume)-- After 6 hours exposure in atmosphere of 120 F. and 90% relative humidity 0.9%.
Federal HH-M-61a -- Pipe Covering. Blocks and Cement.
MIL-I-2819- Blocks Class a -- Filter Mold. Test Reference EES B-7571. Class a -- Super-Light. Test Reference EES 1DDT411.
Super-Light block has smooth surface, uniform thickness and sharp, true edges. Makes tight, efficient joints. Super Light blocks can be used at temperatures up to 600 F.
DESCRIPTION
Super-Light is composed of not less than 85% basic hydrated carbonate of mag nesia, and 10% to 15% specially selected and prepared long asbestos fibers.
FEATURES
Super-Light 85% Magnesia is strong, moisture resistant, shock resistant and smooth finished. It is a material with low conductivity' and high dimensional stability. Super-Light Magnesia has no tendency to induce corrosion on metal surfaces to which it is applied as insula tion. Blocks will not disintegrate, crack or crumble under normal service con ditions....can be removed and reapplied when necessary. Excellent workability makes Super-Light easy and economical to apply.
After being boiled in water for 24 hours, Super-Light 85% Magnesia shows no evi dence of disintegration or change in shape. Water test reveals unusual stabi lity of Super-Light's chemically "set" monolithic structure.
Navy 21 Yc -- Pipe Covering and Blocks. Navy 32P10B -- Cement AMSC 35 - Type H2
APPLICATION
RECOMMENDED THICKNESS TABLE
Temp. Range --
Recommended
F.
Thickness--In.
100 to 201 to 301 to 401 to
200 300 400 600
W/t 2 2-'/i 3
Sizes: Super-Light block is available in
the standard size, 6" wide by 36" long,
in thicknesses of 1", V/i", 1|4", 2",
2'/," and 3".
*
Government Specifications: Super-Light 85% Magnesia block meets these govern
ment specifications when orders specify this requirement.
Super-Light 85% Magnesia blocks are
usually held in place with No. 14 or No.
16 Gauge wire spaced approximately 12"
apart. Joints are pointed up with 85%
Magnesia or Carey Asbestos Cement. As
additional securement, Carey Fibrous
Adhesive can be usedto adhere blocks to
surfaces. Hexagonal wire mesh (l|.j") is stretched tight over the blocks as a
reinforcement for the finish coat of
asbestos cement, approximately
thick.
Segmental blocks, for covering large
pipes, are applied with No. 16 steel wire loops spaced approximately 12" apart. Loops are pulled tight and imbedded in the surface of the covering. Canvas jackets are then pasted on. Application of metal bands is optional.
USES
Super-Light 85% Magnesia block is an efficient insulation for all types of heated equipment in power plants and process industries. It is used on boilers, tanks, kilns, ovens and other equipment having temperatures up to 600 F.; or, it can be used as an outer layer over Carey Alltemp where temperatures range from 600 F. to 1600 F.
SPECIFICATIONS
Density -- Approximately 10 to 11 lbs. per cu. ft.
Flexural Strength -- 40 to 50 ibs. per sq. in. modulus.
Compressive Strength (at 5% deformation! 60-65 lbs. per sq. in. Impact Strength (blocks 6" wide by 1-K" thick) - 15 ft. lbs.
Shrinlege - 0.5% at 500F.
CAREYTEMP PIPE AND BLOCK
industrial 'insulation
Careytemp can be cat cracker-thin without crumbling. Doe to precision molding process, edges are neat and square provid ing tight joints. Careytemp requires no special tools, saves time and costs, simplifies plant clean-up*
Careytemp's exceptional strength and light weight reduces application costs on every job. Analytical balance shows that block of Careytemp, cut to exact dimensions of regularsize cigarette package, weighs as little as 10 cigarettes.
DESCRIPTION
Careytemp is an exceptionally strong, light weight insulation made in both block and pipe form. It is composed of expanded perlite ore, reinforced with an inorganic fibre and with a binder developed especially for this insulation product. The expanded silica (perlite) is an inorganic cellular body consisting of millions of individual vitrified (glassed-in) air ceils which retain their structure permanently and thereby resist water penetration.
Careytemp is recommended for tempera tures up to 1600^F; thermal conductivity over the entire range is extremely low. This insulation exhibits a high degree of resistance to acids and to corrosion.
USES
Careytemp pipe and block insulation is recommended for all types of installa tions with operating temperatures up to 1600F. With the addition of suitable vapor barriers it can be used on equip ment or piping operating at sub-zero temperatures.
Careytemp will not contribute to the stress corrosion cracking of austenitic stainless steel, in acid resistance tests Careytemp has withstood complete im mersion in both 25% solutions and con centrated aqua regia, hydrochloric and sulfuric acids for 100 hours.
Due to the combination of light weight.
low thermal conductivity and low mois ture absorption, Careytemp is particularly suitable for process industry and power plant applications.
APPLICATION
Careytemp is applied accordingto stand ard insulation industry methods and practices. No special tools or equipment are required.
Standard thicknesses or built-up multiple layers can be applied. Due to extremely low moisture absorption, the use of nonbydraulic setting cements with Carey temp is not recommended. Mineral wool cements provide a superior, rigid cement finish. Carey MW-50 or MW-one are recom mended.
Sizes: Pipe insolation is presently available in all copper tube sizes through 3** and in iron pipe sizes through 6**. Block is available in widths of 6*' and 12", in thicknesses from 1*' through 3'* and in lengths of 18" and 36".
A cixrent established program to provide sectional pipe insulation through 26*' IPS will be completed in the near future.
Jackets: Standard canvas, heavy weight canvas and weatherproof roofing jackets are available.
SPECIFICATIONS
Density: 9 lbs. per cu. ft.
Transverse Strength: 70 lbs. per sq. in.
Compressive Strength: 65 lbs. per sq. in. (with 1% deformation)
Linear Shrinkage: .7% at 1200F. 1.2% at 1500F.
Water Absorption: .2% in 24 hours at 90% R.H.
Thermal Shock: Hot and cold cycle test, 400 to 15F., no damage.
When immersed in liquid Nitrogen at minus 325F., so damage.
Acid Resistance: When immersed in sul phuric, hydrochloric acid or aqua regia, no damage in 100 hours.
Corrosion Resistance: Non-corrosive. Composed of chemically inert material.
Temperature Range: Up to 1600F.
Thermal CONOUCTiviTr
l. 1
1 iH
j 1
i , -] 1-
;
i
;
i
| -rl
1
:
I
--hr
Mi
-- -J--------l--i-l. | | T|
11 m ;' H--i ; i 1 ! ! i
rrrr 1 ! M ii
' H ! i i>^! i : --Tl
, 11
III!
!:
i
~t ! ! 1
ii> 11 '
:
:
1
! 1"
i
: 1 : ? ->< . i 1 1 , (
Jr* \ 1 1 1 i
j:.i!; !!|11.
zn:Ill' T 1 1 1 1 ' 1 * > I 1 *! '` `' Ii 11 '1 1 i ,
ioe ;oo joo oo wo too ?ac aoc oe >oec
MEAN TEMPERATURE '(
Carey Industrial Insulation
Careytemp Pipe and Block
DATA* USING RECOMMENDED THICKNESSES
Pipe Temp. Temp F. Diff.
380 300 Recom'd Thk. Btu Loss Surface Temp. F. % Efficiency
580 500 Recom'd. Thk.
Btu Loss Surface Temp. F. % Efficiency
780 700 Recom'd Thk. Btu Loss
Surface Temp. F. % Efficiency
880 800 Recom'd. Thk* Btu Loss
Surface Temp. F. % Efficiency
1080 1000 Recom'd. Thk. Btu Loss
Surface Temp. F. % Efficiency
1280
1200
Recom'd. Thk. Btu Loss
Surface Temp. F. % Efficiency
Careytemp
Pipe Size
80F. Air
1* 3* 4' 6' 8' 10' 12' 18'
V 1' 85 115 122 125 86.8 87.6
1*4' 103 111 91.2
1*4' 143 115 91.5
1*4' 174 115 91.9
2' 165
108
93.8
2' 193
109
93.8
2' 274
112
93.7
1*4' 122 128
92.1
r
134 120 94.0
2' 160
122 94.4
2*4' 184
117 95.5
2*4' 216 117 95.9
2*4' 263 119 96.0
3' 265 113
96.5
3'
369
118 96.5
2*4' 143 122 95.2
2*4' 181 127
95.8
3' 191
121 96.6
r 252 125
96.9
3*4' 270 120 97.4
3*4' 322 122
97.5
3*4' 368 124
97.6
3V4' 506 128 97.6
2*4' 170 129 95.8
3" 197
126 96.6
3* 229 128
96.9
3*4' 268 125
97.5
3*4' 324 127 97.7
4' 353 124
98.0
4' 399 126
98.0
4' 546 130 98.0
2*4' 235 145 96.5
3" 270 142
97.2
3*4' 288 134 97.7
4' 339 131
98.1
4' 406 134
98.5
4*4' 432 130
98.5
4*4' 506 133 98.5
4*4' 682 138 98.6
3279
149
96.9
3*4' 335 143 97.8
4'
347
141 98.3
4*4' 416
139 98.6
4*4' 494
143 98.7
5' 546 139 98.8
5' 595
139
98.9
5*4' 750
141 99.0
*Btu Losses are per Linear Ft.
DATA FOR CAREYTEMP BLOCK
Inner Surface Temperature F.
1' 1*4'
Insulation Thickness
2' 2*4'
3'
3*4'
80F. Air. 4' 4*4'
5' 5*4'
Btu Loss 380 Sur. Temp. F.
% Efficiency
98 134
90.1
69 120 93.0
-53
112 94.6
42 106
95.8
35 102 96.5
31 100
96.9
Btu Loss 580 Sur. Temp. F.
% Efficiency
184
171 92.3
126
147 94.7
98 134
95.9
81 126 96.6
67 119
97.2
57 114
97.6
49 110
97.8
44
107 98.1
40 106
98.3
38 104 98.4
Btu Loss 780 Sur. Temp. F.
% Efficiency
200
177 95.7
152
158 96.8
125
146 97.3
106 136
97.7
91
130 98.0
-79 124 98.3
70 120 98.5
63
117 98.6
58 115 98.7
Btu Loss 880 Sur. Temp. F.
% Efficiency
185 171 97.1
148 157
97.6
126 146
98.0
108 139
98.3
95
132 98.5
84 128 98.6
76 124
98.8
70
121 98.9
Btu Loss 1080 Sur. Temp. F.
% Efficiency
206 179 98.1
172 166
98.4
149 156
98.6
132 148 98.7
117 -106 142 136
98.9 99.0
97 133
99.0
Btu Loss 1280 Sur. Temp. F.
% Efficiency
226 186 98.7
195 175
98.8
172 166
99.0
153 158
99.1
138 -126 151 146 99.2 99.3
*Btu losses are per hour per square foot Indicates recommended thickness.
ALLTEMP PIPE COVERING
[industrial Insulation
ant, extremely durable and will with stand packing, shipping and handling with little, if any, breakage. It does not cut, scratch or otherwise irritate appli cators* hands and skin.
USES
broken-joint double-layer construction. It can also be installed as an inner lave: in combination with an outer layer of Super-Light Magnesia. In combination in
sulation, Alltemp absorbs the initial heat shock of high temperature piping anc brings the temperature down to the safe limit of the outer-layer insulation.
Alltemp Pipe Covering is recommended
for all temperatures from 100 F, to 1600 F. It is particularly recommended
for irregular surfaces, as well as valves and fittings.
Sizes: Alltemp sectional pipe covering is available through 12**; tri-sections and quad-sections available in larger sizes. "Nesting O.D.** pipe covering sizes pro
vide accurate tight fits over or into an
APPLICATION
other size. This permits a wide range of assemblies and gives the advantage of
building up many thicknesses from a
Alltemp is applied in single-layer or limited number of prime units. r
X
Alltemp Pipe Covering is an all-purpose insulation for temperatures from 10(r F. to 1600 F.
DESCRIPTION
Alltemp is a combination of special in organic silicas and asbestos fibres. Every cubic foot is honeycombed with millions of tiny sealed air cells. Having excellent physical and chemical proper ties, Alltemp retains its high thermal efficiency 'and structural strength even when subjected to long and continuous exposure to high temperatures and moist ure.
FEATURES
Alltemp is recommended for high-temperature or low-temperature piping systems.
Extremely low thermal conductivity-- actually improves after exposure to high temperatures.
Full temperature range--from 100 F. to 1600 F.
Low internal shrinkage--lowest of all tested comparable insulations ... approxi mately 40% of most 1200 F. insulations. Alltemp retains high efficiency because it does not crack or open up from shrink age.
Moisture resistance--exposure to high moisture conditions does not deteriorate Alltemp or affect its thermal conductivity.
Easily fitted--workmen can cut and trim Alltemp with a knife, even through can vas covering. They can trim closer and make a truer cut than with other insula tion materials. Edges remain neat and square ... make tight, "no-heat-leaking" joints. It is not brittle ... can be cut or shaped to fit irregular areas and around projections.
Easily handled--Alltemp is shock resist-
SPECIFICATIONS
TABLE OF NOMINAL THICKNESSES, IN INCHES
Nominal
Temperature Difference
Inches
200 300 400 500 600 700 800 900 1000 1100 1200
1-54 & Under 2
2-54 3
3-54 4
4-54 5 6 7 8 9 10 11 12 14 & Over
i
11
1 1-54 1-54 2 2 2-54 2-54
11
1-54 1-54 2
2-54 2-54 2-54 2-54
11
1-54 2 2 2-54 2-54 3 3
11
1-54 2 2 2-54 3 3 3
1 1-54 1-54 2 2 2-54 3 3 3-54
1 1-54 1-54 2 2-54 3 3 3 3-54
1-54 1-54 2 2 2-54 3 3 3-54 3-54
1-54 1-54 2 2 2-54 3 3 3-54 3-54
1-54 1-55 2
2-54 2-54 3
3-54 3-54 4
1-54 1-54 2
2-54 2-54 3-54 3-54 4
4
1-54 1-54 2
2-54 3
3-54 3-54 4
4
1-54 1-54 2
2-54 3
3-54 3-54 4
4-54
1*54 2
2-54 2-54 3 3-54 4 4 4-54
1-54 2
2-54 3 3 3-54 4 4 4-54
1-54 2
2-54 3 3 3-54 4 4-54 4-54
1-54 2 i
i 2-54 i 3 i 3-54 i 3-54 i 4
i 4-54 i 4-54
2-54 3 3
3-54 3-54 3-54 4 4 4 4-54 4-54 4-54 S 5 S
imperatures above 1200, consult the Plymouth Meeting Office for
nmendations.
3 3 3-54 3-54
4 4 4 4-54 4-54 4-54 5 5 5 5 5-54
Corey Industrial Insulation
Alltemp Pipe Covering
* FOR COMBINATION INSULATION OF ALLTEMP INNER LAYER AND SUPER-LIGHT 8S% MAGNESIA OUTER LAYER
Pipe Temp, of
600
700
,00 (
900
00
1100
* 1200
Pipe Size- Inches
1 2 4 6 8 10 12
Reeom'd Thk. (Alltemp
Inches
(Super-Light
BTU Loss
Surface Temp.-- F.
% Efficiency
2"
None 98
118 89.6
1-HM r in
116
93.3
w r*
146 112
95.2
W
\w
190
116 95.7
l-hM W 196 111
96.5
W
1-H" 270 120
96.1
1-H" W 304 120
96.3
Reeom'd Thk. (Alltemp
Inches
(Super-Light
BTU Loss
Surfoce Temp.-- F.
% Efficiency
2"
None 126 126 90.6
1-h" r* 127 114
94.6
W W 184 119 95.7
w W 239 124 96.2
!%" W 286
125
96.4
W 1-H" 341
128
96.6
W 2" 339
122 97.1
Reeom'd Thk. (Alltemp
Inches
(Super-Light
'BTU Loss
,,
Surface Temp.-- F.
% Efficiency
2"
None 154 133 91.5
W4" l-H" 154 121 95.2
1-H" W 222
126
96.2
1-H" 2** 246
123 97.1
1*H" 2" 295
125 97.3
H4M 2" 363 129 97.3
W MS" 364
123 97.7
Reeom'd Thk. (Alltemp
Inehes
(Super-Light
'BTU Loss
,,
Surface Temp.-- F.
% Efficiency
2*'
None
182 141 92.4
1W 179
127
95.7
W W 260 134 96.7
2" 2" 274
123 97.6
2*' 2" 330 127 97.7
2*' 2"
388 129
97.8
2" 2" 457 132 97.9
Reeom'd Thk. (Alltemp
Inches
(Super-Light
'BTU Loss
,,
Surface Temp.-- F.
% Efficiency
2"
None
210 149 93.2
1-J4" 1-J4" 205 134
96.3
2" W 276 133 97.3
2-H" W 332
132
97.7
2" 363 129 98.1
to
2-H" 2" 422 131 98.2
3
1-tt" 491
132 98.3
Reeom'd Thk. (Alltemp
Inches
(Super-Light
*BTU Loss ^
Surface Temp-- F.
% Efficiency
Reeom'd Thk. (Alltemp
-Inehes
(Super-L ight
BTU Loss
_
Surfoce 1 emp.-- F.
% Efficiency
'
2"
None 238 156 94.0
2"
None 266 164 94.7
2M 1-fc" 223 133 96.8
y
1-H" 254 138 97.1
2-fc" W 295 132 97.7
3*' w 315 131 98.1
3" 2" 329 127 98.3
3-%" 1-H" 383 133 98.4
3" 2" 388 129 98.4
3*M>" H*" 451 136 98.5
3" 2" 461 132 98.5
W w 540 140 98.6
3-J4" W 533 135 98.5
w l-H" 600 141 98.7
*BTIJ Losses Are Per Lineal Ft. Per Hr. 80 Ambient Air Temperature No Interface Temperature Exceeds 575 F.
Performance Data For Other Thicknesses See Bulletin 101 BX Alt Recommended Thicknesses Are Nominal
14 16
1-h" W 340 122
96.2
1-J4" 1-H" 390
124
96.2
W 2" 384
124 97.0
1-J4" 2" 419
125
97.1
2" 2" 421
126 97.6
2" 2*' 452
127 97.7
2-V W
498
135 97.9
2-fc" 1-14" 557 136 97.9
3"
W 544 136 98.2
3"
1-tt" 586 137 98.3
3-J4" w* 580
138 98.5
3-J4" 1-JS" 628 139
98.6
3-%" l-fc" 656 144 98.7
3-fc" I-fc" 724
146 98.7
18
Hi" i-hM 438 125 96.2
W 2" 457 126 97.2
2" 2" 495 128 97.8
2-fc" W' 603 137 98.0
3" W 641 138 98.4
3-ttM w 693 140 98.6
3-V4" 1-h" 787 147 98.8
Alltemp is easy to handle, easy to fit ... saves time and labor costs.
ALLTEMP BLOCK
illll'IP i m i
lindustrial linsulation
USES
APPLICATION
Alltemp Block is recommended for high temperature* surfaces such as oil stills, ovens, boiler walls, breechings, fur naces and other equipment whose sur faces are between 100 F. and 1600 F.
Alltemp Block is available for flat and curved surfaces. It is particularly recoin mended for irregular surfaces which re quire an easy-to-apply insulation.
Alltemp Block can be applied as a com plete insulation or in combination with lower temperature insulations (such as Super-Light 85% Magnesia) to absorb initial heat shock. In combination insu lation, Alltemp reduces the temperature to the safe limit of the outer-layer insu lation.
Alltemp block is an all-purpose insula tion within the temperature range of 100 F. to 1000 F.
DESCRIPTION
Alltemp is a combination of special in organic silicas and asbestos fibres. Every cubic foot is honeycombed with millions of tiny sealed air cells. Having excellent physical and chemical properties, All temp retains its high thermal efficiency and structural strength even when sub jected to long and continuous exposure to high temperatures and moisture.
FEATURES
Extremely low thermal conductivity-- actually improves after exposure to high temperatures.
Full temperature range-- from 100 F. to 1600F.
Low internal shrinkage--lowest of all tested comparable insulations. Alltemp re tains high efficiency because it does not crack or open up from shrinkage.
Moisture resistance--exposure to high moisture conditions does not deteriorate Alltemp or affect its thermal conductivity.
Easily fitted--workmen can cut and trim Ailtemp with a knife. They can trim clos er and make a truer cut than with other insulations. Edges remain neat and square ... make tight, "no-heat-leaking" joints. It is not brittle ... can be cut or shaped to fit irregular areas and around projec tions.
Easily handled--Alltemp is shock resist ant, extremely durable and will withstand packing, shipping and handling with lit tle, if any, breakage. It will not cut, scratch or otherwise irritate applicators* bands and skin.
SPECIFICATIONS
Density--19-21 lbs.-per cu. ft. Conductivity--at 100 F....0.43
at 500 F....0.60
at 1000 F....0.72
Crushing strength (3% deformation) -- Cold ... approx. 58 lbs. per sq. in.
1500 F... approx. 60 lbs. per sq. in. Heat expansion--none Heat shrinkage--at 1200 F....0.72%
at 1500 F....1.10*
Flexural strength--60 lbs. per sq. in. Abrasion resistance --
Loss in 1st 10 min................................. 27% Loss in 20 min.........................................55%
airduct.
Packaging: Alltemp blocks are packed in cartons. The same carton packaging data shown under Filter Press 85% Magnesia Blocks also apply to Alltemp blocks ex cept that the weights are approximately 25% heavier.
Carey Industrial Insulation
Data for Combination Insulation of Alltemp Inner Layer and Super-Light 85% Magnesia Outer Layer
Inner Surface Temperature0 F.
600 700 800 900 1000 1100 1200
Recom'd Thk. (Alltemp (Super-Light
B IT Loss Per hq. Kt. Outer hurtace Temp.-- t. Efficiency--%
i-vr i-ir
73 123 97.2
1-K" 2"
78
125
98.0
2" 2** 84 129
98.3
2-lj"
Mr 102 135 98.4
3" l-'4" 108 139 98.7
Based on 80 Ambient Air Temperature No Interface Temperature Exceeds 565 Performance Data For Other Thicknesses See Bulletin 101BX
3-H"
l-K" 111 139
99.0
4"
1-K" 116 L42 99.2
<jT 'deT D.V iter
34" 35" 36" 37" 38" 39" 40" 41"
* *
45" 46" 47" 48" 49" 50" 51"
4r
.
o4" 55" 56" 57" 58" 59" 60"
No. of 6" Ride
Blocks To Cover
18 18 19 19 20 20 21 21 22 22 23 23 -24 24 25 25 26 26 27 28 28 29 29 30 30 31 31
3" Wide Filler Block
1 1 l 1 i 1 1 1 1 1 1 1 1 1
External Area Sq. Ft. Per 3 Ft. Length
2-*4" to 2" Thick
Over 2" Thick
28.692 29.498 30.286 31.083 31.880 32.677 33.474 34.241 35.068 35.865 36.662 37.459 38.256 39.053 39.850 40.647 41.444 42.241 43.835 44.632 45.429 46.226
47.023 47.820 48.617 49.414 50.211
28.980 29.785 30.590 31.395 32.200 33.005 33.810 34.615 35.420 36.225 37.030 37.835 38.640 39.445 40.250 41.055 41.860
42.665 44.275 45.080 45.885 46.690 47.495 48.300 49.105 49.910 50.715
Alltemp Block
HI-TEMP NO. 19 BLOCK
industrial
Einsulation
APPLICATION
SPECIFICATIONS
Hi-Temp No. 19 Block insulation for temperatures up to 1900 F.
Blocks for insulating refractory brick surfaces are usually laid up with HiTemp Cement and supported in place by an outer wall of metal or brick. Blocks for application over superheated steam surfaces are held in place with wire loops or other supporting means as described for 85% Magnesia Blocks. Fibrous adhesive can be used to adhere blocks to surfaces as an additional securemem but only when surfaces do not exceed 800 F. For higher tempera tures, blocks should be wired to the surface. Consult the Insulation Contract Department or the Plymouth Meeting Office when conventional methods of application cannot be used.
Furnished in flat and curved blocks for covering large surfaces. Also furnished as cement to be mixed with water for filling cracks and openings between blocks.
Packaging: Hi-Temp blocks are packed in cartons. The same carton packaging data shown under Filter Press 85% Magnesia blocks also apply to Hi-Temp blocks except that Hi-Temp weights are 50% heavier. Density of Hi-Temp is approximately 24 lbs. per cu. ft.
/
DESCRIPTION
TABLE OF RECOMMENDED THICKNESSES
Temperature Range-- F. Hi-Temp Inner Layer--In. 85%Mag. Outer Layer--In.
Carey Hi-Temp No. 19 Clock is made of diatomaceous earth, asbestos fibre and refractory bonding clay molded into block form for greatest use at high temperatures.
FEATURES
1101 to 1200 1001 to 1100 901 to 1000 801 to 900 701 to 800 550 to 700
3-1/2
3 2-1/2 2 1-1/2 1-1/2
1-1/2 2 2 o
2-1/2 2
. High thermal efficiency--K Factor
(conductivity) at 600 F. mean tem
perature (average between inner and
outer surfaces of insulation) is 0.64;
at 8000
o.68; at 1000 F., 0.69.
. Heat expansion up to 1900 F.--none.
Standard Sizes*. Lengths - 18" and 36".
Width
' Thickness -- Inches
6*' Curved
9" 12'* Flat 3", 6" Flat
1-1/2, 2, 2-1/2, 3 1-1/2, 2. 2-1/2, 3, 3-1/2, 4 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 3-1/2, 4
< . Incombustible--all mineral. y
. Noncorrosive.
. High compressive strength--approx imately 95 ibs. per sq. in.
. High bending strength--modulus ap proximately 75 lbs.
. Small heat shrinkage--0.4% at 1000 F.; 1.00% at 1500F.;2.5% at 1900O F.
. High salvage value--broken material can be ground and used as cement. .
USES
For use in insulating ovens, furnaces, kilns, lehrs, regenerating chambers, breechings and ducts where the outer surface of the refractories does not exceed 1900 F. In general, blocks are used as a first layer, followed by an outer layer of 85% Magnesia in such corebinhtions that the 85% Magnesia will not be exposed to temperatures higher than 600 F.
WOOL FELT PIPE COVERING PERFECTO
^industrial (insulation
Recommended Thicknesses --
and end joints staggered and brought
Temperatures 225 F. to 60 F. -- Normally, 3/4" thickness is satis factory, but for severe humidity conditions
together firmly. When insulating piping, operating in the lower range of recom mended temperatures, joints of the inner
double 1/2" thickness is recommended. layer should be sealed to prevent the
Temperatures from 60 F. and 45 F. Double layer construction is also rec ommended. Also, see Page 12 (Impervo).
infiltration of moisture. Covering shall be secured in place by pasting down the side and end laps of the factory applied canvas jacket. If additional securement
Sizes: Perfecto is furnished only in semi-cylindrical sections 36" long, for pipe sizes up to and including 36". It is available with bands in thicknesses of 1/2", 3/4", 1", double 1/2", double 3/4". Other thicknesses available on
is desired, copper staples shall be in stalled under the canvas lap and over the side joints. Standard metal bands are also used as additional securements. Bands should be placed at end joints and in the middle of each section.
special order.
Fittings shall be insulated with one or
more layers of Hairfelt built up to a
thickness equal to the adjacent pipe in
t
DESCRIPTION
APPLICATION
Note: To insure maximum efficiency
sulation. It is recommended that each layer of Hairfelt be sealed with spiral wrapping of insulating tape. Finally, the
Perfecto is a semi-rigid structure made of multiple layers of indented "dry" insulating felt (wool felt) firmly cemented
pipes and fittings must be installed to allow a full thickness of insulation to be applied throughout.
fitting should receive a smooth coat of Asbestos Cement and a canvas jacket neatly pasted in place. In the lower
together. The inner surface is lined with asphalt-saturated organic fell. Carey Perfecto covering is furnished with a white wrapper under the canvas.
Single Layer -- Sectional Covering shall be applied to the straight run of pipe with all joints brought together firmly. Cover ing is secured in place by pasting down
temperature range we recommend that the outer layer of insulation be stepped back approximately 1-1/2" from the end of the inner layer at fittings, and when insu lating over hangers. This will provide
USES
the lateral and end laps of the factory the broken joint type construction applied canvas jacket. If additional throughout, which is very important when
Perfecto is an efficient economical pipe securement is desired, standard metal insulating against condensation.
insulation for temperatures between 60 F. and 225 F., keeping hot water hot and cold water cold, and preventing
bands may be installed over end joints and in the middle of each section.
All piping exposed to the weather should be waterproofed. We recommend that the
sweating of cold water service lines. Fittings in lines covered with single straight pipe be weatherproofed with 45
For service water temperatures between layer (Perfecto W'ooifelt) can usually be lb. Surety Roofing which is an asphalt
45 F. and 60 F., integral jackets with insulated with MW'-SO cement. The saturated and coated jacket. Side and
properly sealed joints give adequate fittings shall be roughed in to a thick end laps should be a minimum of 2"
service for intermittant operation. For ness equal- to the adjacent insulation and sealed with lap cement. To insure
continuous operation a water vapor and allowed to dry. After the cement is best results all side laps should face
\ barrier integral jacket should be used. thoroughly dry, fittings should be downward to shed water and the jacket
Under such conditions refer to Impervo smoothed off with a second coat of held in place with loops of copper clad
and Table of Recommended Thicknesses Asbestos Cement and canvassed.
wire on 6" centers. Fittings exposed to
on next page. Perfecto is not designed
the weather shall be weatherproofed with
for dual temperature systems.
Double Layer -- Perfecto shall be applied Carey Insulation Seal and reinforced
Note -- In cold or chilled water line pip to the straight runs of pipe with lateral with Ciasfab.
ing all conditions such as air tempera
ture, humidity, type of insulation, or any
extreme condition must be considered
carefully. If proper precautions are not
taken in the choice of insulation and in
its installation, sweating and condensa
tion can cause extensive damage thruout
the building.
SPECIFICATIONS
Perfecto has a very high insulating value, much better than old-type solid wool felt coverings. K-Factor (conduc tivity) is approximately the same as cork and hair felt .25 to .30 at 50 F.
Perfecto is finished with 10.2-yards-perpound cotton cloth jackets. Heavier canvas jackets can be furnished. Per fecto can be finished with roofing jackets, such as the Carey recommended
jacket of 45-lb. Surety Roofing.
Carey Perfecto is shown installed in Cincinnati, Ohio food plant. Perfecto can be used to insulate service water piping systems down to 45.
WOOL FELT PIPE COVERING IMPERVO
industrial insulation
DESCRIPTION
Impervo is composed of multiple layers of insulating felt with water resistant felts on the inner and outer surface of each layer. It is furnished in sections three feet long with canvas jacket, for ' ' iron and copper pipes from 1/4"
M", and is regularly made in Double a and Double 3/4" thickness. Other th>^icnesses can be made special to order. Four inch (4") wide collars for sealing end laps, as well as longitudinal flaps on outer water resistant felt will be furnished special on request.
USES
vo is used primarily for insulating chilled water and ice water pipe lines operating at temperatures between 40 F. and 60 F. It is specially designed to keep water cold and prevent condensa tion causing damage from dripping. Recommended for cold service water piping under particularly high humidity conditions such as in laundries, kitchens, bakeries, textile and paper mills.
SPECIFICATIONS
Impervo has a high insulation value, approximately the same as cork and hair felt. Its K Factor (conductivity) is in the range of .25 to .30 at 50 F.
Service Range: Impervo used to proper ' nesses is recommended for cold
'e water service. The table shows ti. oper thickness to prevent sweating for various differences of temperatures between the surrounding air and water in the pipe and for various degrees of humidity:
Humidity
Temperature Difference of. Water To Air
S0 F.
60 F. 700 F.
Max. In. Max. In. Max. In.
Up to 70% 70-80% 80-85%
1" M4" 2"
1"
2" 2-H"
Mi" 2"
3"
In cases where water temperatures are 50 F. and beiow and relative humidity exceeds 75%, special precautions must be taken to assure proper vapor sealing of all joints and surfaces to prevent the infiltration of moisture vapor through the insulation. This should include the following:
1. Use of longitudinal flap and 4" collars at all end joints, properly sealed with Carey Insulation Seal No. 830.
2- All fittings to be made from standard hairfelt securely sealed to adjacent layers of covering with insulating tape.
3. Where severe conditions exist, sur face of both pipe insulation and fittings must be brush coated with Carey Insulation Seal No. 830 to assure a proper moisture vapor seal.
Impervo is not recommended for the in sulation of most dual temperature systems. Consult General Office for recommendation of type of Impervo in sulation for dual temperature systems, giving maximum percent of humidity and maximum air temperature.
APPLICATION
All piping and fittings shall be insulated as follows:
Chilled rater Piping Systems: Pipe In sulation - Apply two (2) layers of Carey Impervo. Pipe Covering of thickness in agreement with preceding table, with all butt joints and lateral seams of the second layer staggered with reference to joints and seams of the first layer. Point all joints of inner and outer layers with Carey Insulation Seal No. 830.
All covering must run continuous in full thickness through sleeves and be properly tied in with fittings and vapor sealed.
Covering may be secured in place by peeling back canvas and longitudinal flap (when ordered) and installing 3/4" x 3/4" or larger copper staples over longitudinal seams on 6" centers. Width of staple must be sufficient to extend over joint.
After insulation is secured in place oement down longitudinal flap and collars with Carey Insulation Seal No. 830.
At fittings and valves, step back the outer layer of covering at least 2". making sure that all seams are light.
Support all insulated lines by Clevis hangers placed on outside of insulation, using a heavy gauge sheet metal saddle through the hanger. Spacing of hangers and size and length of saddles must provide sufficient - load distribution to prevent compression of insulation. Saddles should be formed to exact out side diameter of covering and should extend half way around covering. Where other types of bangers are used a perfect seel must be provided, and the insulation carried up the hanger rod for at least 6".
Fittings: insulate with two (2) layers of Hairfelt, each layer lied on with spiral wrapping of 4-ply hemp twine. Apply the first layer of Hairfelt tight against the butt ends of the inner layer of covering and approximately flush with the outer surface of the inner layer. Apply the second layer of hairfelt tight against the butt ends of the stepped back outer layer of covering and ap proximately flush with outer surface of covering. Seal each layer of Hairfelt with a spiral wrapping of insulating tape pulled tight, and lapped on itself to give double thickness. Tape should be extended at least 2" over the ad jacent pipe insulation. Seal each layer of insulating tape with a heavy brush coat of Insulation Seal. Where pipes are exposed, fittings may be finished over insulating tape with a smooth coat of Asbestos Cement, (omitting Insulation Seal) applying a canvas jacket over the Asbestos Cement with a waterproof adhesive. Outside piping, fittings, hangers and vessels may be weather proofed with Insulation Seal No. 830 reinforced with Glasfab or equal.
Finish: Thoroughly seal all insulation surfaces with a heavy brush coat of Insulation Seal.
Cold City and Well Water: Apply in sulation same as above except the second layer of hairfelt on fittings and the finish vapor barrier coating over the insulation may be omitted.
Recommendation for conditions other than described above can be obtained from the Technical Services Department of The Philip Carey Manufacturing Company.
Humidity varies greatly over the United States. At times conditions are unusual and excessive. Data showing these extremes of temperatures and humidity may be obtained from your local Weather Bureau.
WOOL FELT PIPE COVERING PROTECTO
industrial 'insulation
canvas jackets can be furnished. Pro tecto can be finished with roofing jackets, such as the Carey recommended jacket of 45-lb. Surety Roofing.
Recommended Thicknesses --
Single layer (1-1/4" thickness) is usually satisfactory for latitudes south of
Washington, D.C., Cincinnati and St. Louis. Single layer 2" total thickness is recommended for northern latitudes.
Effective Protection: No insulation alone can prevent freezing if the water stands still long enough. Some water must be allowed to run during weekend or idle periods.
PROTECTION PERIOD AGAINST FREEZING AIR-10 BELOW ZERO F. WATER-520 F.
Protect reduces the danger of freezing of exposed piping.
DESCRIPTION
Protecto is a semi-rigid structure made of two inner layers of cattle hair felt (each layer about 1/4" thick) and an outer layer of insulating felt (wool felt) firmly cemented together. The inner * surface is lined with asphalt-saturated organic felt.
USES
Hours offProtection
Pipe Size
Before Freezing
Allowing 1/8" thickness of ice to form
W Thk. 2" Thk. J-J4" Thk. Protecto Protecto Protecto
2" Thk. Protecto
1" 2"
3"
4" 6" 8" 10" 12"
1.02 2.59 4.23 5.94 9.67 13.22 17.16 20.95
1.54 4.2 7.15 10.2 17.4 24.3 31.7 38.7
4.94 7.59 9.70
11.65 15.70
19.47 23.49 27.38
7.92 12.3 16.40 20.09 28.1 35.65 43.45 50.75
Flow Seeded To Prevent Free zing-- lbs of water 'tin. ft. of pipe 'hr (1 pint 1 lb)
7-W" Thk. Protecto
2" Thk. Protecto
.37 .56 .75 .92 1.33 1.64 1.98 2.33
.25 .35 .45 .54 .72 .89 1.07 1.26
Protecto is used only to protect water, gas, oil and other pipes from freezing temperatures. It should never be used on ice water pipes to prevent sweating.
SPECIFICATIONS
K-Factor (conductivity) is approximately .25.
Protecto is finished with 10.2-yards-perpound cotton cloth jackets. Heavier
APPLICATION
Protecto sectional covering shall be carefully fitted to the pipe with lateral and butt joints tight. The sections are secured in place by neatly pasting the side and end laps of canvas furnished on the covering. Protecto covering may be additionally secured with standard metal bands placed over end joints and in the centers of each section. Cover
the fittings with Hairfelt built up to equal thickness of the adjacent covering and secure in place with a spiral wrapping of jute twine. Fittings may be finished with insulating tape or asbestos cement and a canvas jacket pasted in place.
It is recommended that the insulation be painted with one coat of size and two coats of lead and oil.
/ \r
V
v
SUPERBO PIPE COVERING
industrial
rinsulation
Flair-door staples or other devices which puncture the vapor barrier must
not be used to hold down tbe flap. Standard bands should be used to hold down tbe flap until tbe adhesive sets after which they may be left in place or removed for subsequent painting or canvassing, joint collars are to be sealed down with vapor barrier adhesive.
Ends of the pipe insulation shonld be sealed off with a cot back type asphalt mastic, such as Insulation Seal 830,
at all flanges, valves and fittings and at intervals of 21 feet on continuous runs of pipe. These moisture seals retard the spread of moisture should barrier puncture or line failure occur.
Carey Superbo is available with either a white or a black vapor barrier jacket con sisting of aluminum foil laminated between two layers of creped Kraft.
DESCRIPTION
Carey Superbo is a rigid pipe insola tion made of moltiple layers of "dry" insolating felt (wool felt) firmly cement ed together. The inner surface is lined with asphalt saturated organic felt. A factory applied white vapor barrier jacket is furnished consisting of alu minum foil laminated between two layers of special creped Kraft paper, bonded with asphalt. This same vapor barrier jacket is also available with a black outer surface.
Superbo is furnished with 4" wide collars of the ttoe vapor barrier material as the jacket.
APPLICATION
Superbo should be applied over a clean dry surface (wipe off any condensed moisture) with the pipe at ambient tem perature. Adjoining sections should be firmly butted, and if multiple layer construction, all joints are to be stag gered. Tbe longitudinal flap of the vapor barrier and the collars should be sealed down with a suitable rubber base vapor seal adhesive.
Vspor seal adhesives should he quick tacking. Where the white side of the barrier is exposed a white adhesive should be used.
In erecting the pipe, tbe use of adjust able clevis type hangers with the insu lation passing through the hangers is a preferable mounting, particularly in severe service conditions. The use of saddles, consisting of semi-cylinders of 16-gauge galvanized of a length equal to 4 times the diameter of the pipe insulation is indicated in all cases. In the case of large diameter pipe, where high concentrated loads axe expected at the points of support, the use of a abort length of rigid type insulation on the lower half of the pipe through the hanger loop is recommended to prevent compression of the insulation.
If direct contact clamp hangers are used, the hanger is to be insulated independently of the straight run cover ing in the same manner as any valve, flange or other type of fitting by the following method.
1. Hanger rod should be insulated to a minimum height of four times, the pipe insulatiou thickness (or prefer ably 12*' where possible) with inso lation similar to that covering tbe
USES
Carey Superbo is a doal temperature pipe insulation for chilled water piping or piping operating at alternating high and low temperature with a service range of from 35 F. (lower limit) on the cooling cycle to 200 F. (maximum)
on the heating cycle. The integral vapor barrier jacket properly applied and sealed will protect chilled water lines from condensation or sweating. Thickness requirements vary with the pipe size and conditions oftemperature and humidity. Where recommended thickness exceeds 1-1/2** and the pipe size is 6** and over, double thick Superbo construction and broken joist application is required.
The longitudinal flap of the vapor barrier should he sealed down with a rubber base vapor seal adhesive.
Vapor seal adhesive should be quick tacking. Banda may be used to hold down tbe flap until adhesive dries.
Corey Industrial Insulation
Superbo Pipe Covering
pipe, having an I. D. approaching as nearly as possible the diameter of the hanger rod and one-half the is* 'alation thickness used, on the pipe
oper.
2. l he hanger rod insolation, the inso lation collar over the clamp, and the area extending 2*' beyond the collar on each side should be sealed with 2 coats of a cot back type asphalt mastic (Insolation Seal No. 830) re inforced with saturated glass fabric between coats.
3. The area boosing the clamp hanger between the ends of pipe insolation should be closed by a collar of in solation materialsimilar to that osed on the pipe, with an 1. 0. equal to the 0. D. of the pipe insolation and half the thickness, and shall extend two inches over the ends of the pipe insolation on each side, and be sealed as described above.
e ends of tbe pipe insolation eniosed by the joint collar should be moisture sealed with a cot back type asphalt mastic (Insolation Seal 830),
5. The voids in the area boosing the clamp hangershoold be firmlypacked with hair felt.
6. The pipe insolation should have Starrier laps firmly sealed in the ;me manner as on the straight rons pipe.
FINISHES As an indoor strface
finish, the barrier surface may he considered adequate with or without bands. The barrier may not he painted directly. Paint tbe barrier with asphalt base alominom paint or other asphalt compatible finish. Follow with con ventional lead and oil paint. Pigment ed PVA emulsions in code colors also serve as highly desirable final finishes.
Insulated piping exposed to the weather should he finished with 45# roofing felt lapped at least 3** at all joints and sealed with lap cement. Edge of the
horizontal lap should end slightly be low the level of tbe horizontal axis of the pipe in order to shed water. Final securemeas should be made with soft aluminum bands on 12*' centers or 16gauge galvanized or copper wire on 8" centers. Wire should not be drawn so
tightly as to pierce the jacket.
SPECIFICATIONS
Sizes Available . .......................... 1/2** through 36** Iron Pipe Size 1/2** through (bl/8" Copper Tubing
Semi-cylindrical sections -36** in length-binged
Thickness.......................................... 1** and 1-1/2** thickness
Jackets............................................. White Vapor Barrier
Black Vapor Barrier Collars 4** wide furnished with each section
K Factor.................................................. 29 at 50 F.
Vapor Transmission....................
Vapor barrier jacket has a Perm, rating after flexing of O.Oz Max. at 95% RH at 100<> F.
Jacket has a 15% stretch characteristic in both directions.
TABLE OF RECOMMENDED THICKNESSES FOR AMBIENT AIR CONDITIONS OF 90 F. & 90% R.H.
(Based on "K" of .28 9 40 F. Mean)
IRON PIPE SIZES
COPPER TUBING
Other fittings such as elbows, teea, flanges and valves shall also be insolated independent of the straight ran covering. After the ends of the adjacent covering has been sealed with mastic (Insolation Seal No. 830), the body of the valve, tee, elbow or flange should b? -atly covered with hair felt securely li r place, of a thickness eqoivalent to me adjacent insolation. The fitting insolation is then shaped by enclosing the hair felt neatly taped with pressure sensitive black vapor barrier tape. If moltiple layer broken joint construc tion is employed, the ends of the inaulation sbouldbe staggered at the fitting and separate layers *f hair felt carried through the fitting irsolation with tape between each layer. The taping should be extended a foil two inches on each side, on each layer, of tbe adjacent covering. A final outer vapor seal should be accomplished by two coats of vapor seal mastic (Insolation Seal No. 830) reinforced with saturated glass fabric between layers and carried oi* two inches on each side on tbe adjacent covering. If color is a factor, a whire form of tape is available, and tb* final finish coat can be made with
us of white robber base vapor seal ive reinforced with an untreated
g fabric.
AQ valves, bandies, stems or other protuberances on fittings shoold be erected in an inverted position. Inso lation should be carried oot contin uously through all walls, partitions or other interfering structmes.
Temperature
350 F
40 F
Temperature
35 F
40 F
Size
Recommended Recommended Thickness Thickness
Size
Recommended Recommended
Thickness
Thickness
1/2" 3/4"
r* 1-1/4" 1-1/2" 2'* 2-1/2" 3*' 4" 5** 6** r* 8'* 9** 10" 11" 12" 14** 16" 18** 20" 24" 30" 36**
1-1/2" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2'* 2" 2" 2-1/2** 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2** 2-1/2" 3" 3" 3" 3" 3"
3"
1-1/2" 1-1/2" 1-1/2** 1-1/2*' 1-1/2" 1-1/2" 2" 2** 2" 2" 2" 2" 2" 2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2"
1/2" 5/8" 3/4" 7/8" 1-1/8" 1-3/8** 1-5/8" 2-1/8" 2-5/8" 3-1/8" 3-5/8" 4-1/8" 5-1/8" 6-1/8"
1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2*' 2" 2" 2" 2" 2" 2" 2-1/2" 2-1/2"
1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2" 2" 2" 2" 2**
Insulatioo thickness s h o n 1 d in all cases he chosen to meet the severest possible conditions of temperature and
relative humidity anticipated on the lower end of the cycle when used in
dual range or chilled water service.
CAREYCEL PIPE AND BLOCK INSULATION
Fmdustrial ^insulation
SPECIFICATIONS
THERMAL CONDUCTIVITY
large amounts of water vapor, the thick ness of Careycel should be selecte from the table, choosing the worst con ditions of relative humiditv and tempera ture differential, and a vapor barrier mus be provided to seal outer surface. A! thicknesses specified incorporate . safety factor of 10% to 20% over th indicated thickness actually required tc prevent condensation of moisture on ttu insuiation surface.
SIZES:
Pipe Coverings: Careycel pipe covering! are furnished in 3-foot split cyiindrica sections, in thicknesses of 1", 1-1/2'' and 2", for iron pipe or copper tubing Cotton jackets are attached.
Blocks and Sheets: Flat blocks are fur
Careycel Pipe Covering and Block t Insuiation has 12 or more layers of pre
MEAN TEMPERATURE F.
nished in standard 6" x 36" size Standard sheet or board size is 36" x 36'
formed asbestos paper per inch of thick Careycel Board is especially recommended but special sizes can be furnished up t<
ness -- each layer being an effective for a neat and workmanlike appearance 36" x 96". Thicknesses: 1/4" to 3'
heat barrier. This special construction gives Careycel a much lower K Factor
on exposed duct work. One-inch thick Careycel is recommended for all appli
in 1/8" increments.
than conventional corrugated asbestos cations except air-conditioning ducts Packaging: Careycel pipe covering ii
insulation, such as Aircell and Excel. in high-humidity surroundings. For a duct packed in dirtproof, moistureproof carton?
DESCRIPTION
passing through a laundry room, kitchen, to minimize waste and breakage. Block? or where any heated equipment emits and sheets are also specially packed
Careycel is designed for temperatures up to 300 F. and is an improved type of asbestos heat insulation for pipes, heaters, and hot or cold air-conditioning ducts. Careycel provides greater in sulating efficiency for a given thickness, a feature which is the result of a patented processing method.
Each sheet of asbestos paper is fabri cated with innumerable minute indenta tions that are deep and firm. In forming Careycel, these sheets are laminated to provide any desired thickness. Careycel has 12 or more asbestos layers per inch of thickness, each layer being an ef fective heat barrier.
Relative Humidity
60% 70% 80% 85% 90%
Careycel 'Diickness Required to Prevent Sweating Temp. Differential -Room Air To Duct Air
20 F
25 F
30 F
35 F
40 F
45 F
1/4" 1/2" 3/4"
1-1/4" 2"
1/4" 1/2" 1" 1-1/2" 2-1/2"
1/2" 3/4" 1-1/4" 1-3/4" 3"
1/2" 3/4" 1-1/2" 2"
3-1/2"
3/4" 3/4" 1-3/4" 2-1/4" 4"
3/4" 1" 1-3/4" 2-1/2" 4-1/2"
50 F
3/4" 1" 2" 2-1/2" 5"
FEATURES
High insulating efficiency^xtremely low K Factor.
. Minimum shrinkage--only .05% (about one-tenth of conventional air-cell typ).
. Smooth--no unsightly ridges to catch
and hold dust and dirt.
.
. Firm--easy to handle and install, with
stands more abuse.
. Noncombustible.
. Light weight.
USES
For temperatures up to 300 F., Careycel is one of the most efficient, easily installed, permanent and low cost in sulations for piping (hot water, steam heating system, process), duct systems, ovens and kilns, appliances, and hot equipment such as boilers, heaters, and tanks. One-inch thick Careycel covering gives effective insulation for most of these applications.
Careycel Pipe insulation installed on steam piping in boiler room of Metro-ColdwynMayer movie studios. Culver City, California.
Corey Industrial Insulation
PLICATION
Pip.j: Paste down cloth jacket laps and apply metal hands on 18" centers. In sulate fittings and valves with Carey No. 303 Asbestos Cement, bringing the cement surfaces flush with adjacent pipe covering, and finish with pasted cloth jackets. Paint finish can be one coat of cold-water paint with two coats of lead and oil. Use varnish size in the first coat of lead and oil.
Duct Systems: For ducts up to 18" wide, wire boards in place, pulling wires tight and embedding them in the boards. Space wires on approximately nine-inch centers. For ducts over 18" wide, apply boards with sheet metal screws and tin caps, forcing the caps approximately 1/4*' below the surface of the board. Space screws so that each one supports app/ lately two square feet of board.
Fill all cracks and joints with cement composed of a mixture of 1/3 Portland Cement and 2/3 Carey No. 303 Asbestos Cement. Over all edges paste down eight-ounce canvas strips six-inches wide. Where insulation is applied in exposed places eliminate the canvas strips and finish the entire insulated surface with
'-ounce canvas pasted on. Paint s with two coats of lead and oil
p with varnish size in the first coat.
Hot Equipment: Wire Careycel blocks on approximately 12-inch centers. Over the blocks apply one-inch hexagon wire mesh stretched tight. Follow with a 1/2-inch coat of Carey No. 303 Asbestos Cement (or Carey No. 100 Cement for a very hard fir' ` ), troweled smooth. Finish with ei\^ ounce canvas jacket pasted on, and paint as specified for Careycel pipe covering.
Careycel Pipe and Block
AIRCELL PIPE COVERING AND BLOCK
industrial insulation
Aircell should not be used for outdoor or underground line because it will not support roofing jackets or withstand water.
Sizes: Semi-cylindrical pipe covering is furnished in sections 36" long for pipe sizes up to 36'*. Thicknesses: 12", 3/4", 1".
Aircell can be used at temperatures up to 300 F.
DESCRIPTION
SPECIFICATIONS
Aircell pipe coverings are normally fur nished with white asbestos paper jackets or cotton jackets (10.2 yards per pound) and metal bands. Heavier canvas jackets can be supplied. Aircell coverings are not furnished with factory-applied roofing jackets.
THERMAL CONDUCTIVITY
Aircell blocks are furnished in standard 6" by 36" size. Standard sheet size is 36" x 36", but special sizes can be furnished up to 36" x 96". Thicknesses: 1/4" to 3" in 1/4" increments.
APPLICATION
Pipe Covering-Cold water flour paste is used to secure canvas laps along lateral joints and at joints where sections abut. Metal bands are applied approx imately 18" apart, usually over butt joints and in the center of sections. Fittings should be insulated with as bestos cement.
Aircell is a lightweight asbestos paper structure comprising alternate layers of corrugated and flat asbestos paper firmly cemented together. Corrugations are 1/4'* deep, four plies per inch of thick ness. Aircell is the most economical in combustible asbestos insulation.
USES
Blocks--Blocks are usually held in
place with 14-gauge or 16-gauge wire loops spaced approximately 12" apart. Joints are pointed up with asbestos cement. Carey Fibrous Adhesive can be used to adhere blocks to surfaces
as an additional securement. Hexagonal wire mesh, 1-1/2-inch, is stretched tight over the blocks as a reinforcement when an asbestos cement finish coat is required.
Aircell is designed primarily for indoor heating systems and process piping and equipment where steam does not exceed approximately 70 psi or 300 F. Aircell should be used only where high effici ency, strength and durability are not as important as initial low cost application.
MEAN TEMPERATURE F.
FOR* NO. 700? - REV. W - i K-CL
17
i u.r
DEFENDEX PIPE AND BOARD INSULATION
SPECIFICATIONS
industrial
Einsulation --r*Yr-- - --
THERMAL CONDUCTIVITY
Sizes: Defendex is furnished in seraicylindrical pipe covering sections 36" long for pipe sizes up to 36**. Pipe cover ings are regularly finished with 3.8 ounce cotton duck jackets and bands. Heavier cotton duct or roofing jackets can be furnished.
Defendex is also available in flat blocks and sheets. Blocks: 6" x 36". Sheets: 36" x 36". Special block and sheet
sizes made to order. Standard thickness is 1*', however, thicknesses up to 2-1/2" can be provided.
0.4!1III
I
100 200 300
' 400
f MEAN TEMPERATURE F.
Defendex pipe and board insulation is designed for temperatures up to 550 F.
DESCRIPTION
Defendex is a semi-rigid structure com prising approximately 20 to 22 alternating layers of flat and processed asbestos paper per inch of thickness. The pro cessed asbestos paper contains innumer able, very fine indentations, which give proper spacing between succeeding lay ers. Defendex gives high efficiency at medium price.
Comparative Efficiencies
Table Of Comparative Efficiencies Of 1-inch Thick Pipe Coverings On 3-inch Pipe
Steam Pressure and Temperature
5lh 226.8 F
SO lb. ' 297.7 F.
100 lb. 339.2 F.
200 lb. 387.8 F.
Defendex 85% Magnesia
80.2% 81.6%
82.3% 83.9%
83.2% 84.9%
84.2% 86.0%
USES
\ Defendex is an economical, high effici ency insulation designed to insulate
boilers, pipes, ovens and other apparatus
operating at temperatures not exceeding
550 F. It is also furnished in large curved shapes for metal jacketed boilers.
GMBfTOt STAPLE UP
Defendex is especially adapted for in sulating steam traced pipes. It can be manufactured in any special shape to cover two or more pipes. These sections can be cut as specified, at the top, bot tom or on the side for easy installation.
TUGS UNE
20-22 ALTERNATING LAYERS PER INCH
H&0 APPLIED WEATHERPROOFING
STAPLE
GAUNT OR STAPLE LAP
TUGS UXE
Fireclad or other types of weatherproof jackets can be applied for protection against weather.
TEAR DROP SECTIONS'FOR TRACED LINES
ASBESTOS SPONGE PIPE AND BLOCK INSULATION
findustrial iinsolotion
OPTIMUM ECONOMICAL THICKNESSES FOR AVERAGE CONDITIONS
Pipe Sizes
Temperature Range 0 F Vj to 1-Vj 2 to 3-`2 4 to 6 7 to 10 12 L overm
550 to 700 450 to 549 350 to 449 250 to 349 150 to 249
2" 2"
1-54" 1" 1"
2-5:" 2" 2"
1-!*" 1"
3" 2-5." 2"
1-5-" 1"
3"
z
2" l-vf
3-V 3" 2-1-"
**
I-1:"
This column represents recommended thicknesses also for tanks and equipment.
Asbestos Sponge insulation, for tern* peratures up to 700 F.
DESCRIPTION
Asbestos Sponge is a firm resilient structure made from a series of laminated asbestos felts, averaging 30 to 35 layers per inch of thickness. Closely held air films, both within and at the surface of the layers, give Asbestos Sponge its excellent insulating efficiency.
is applied in the field we recommend that the jacket be applied with a min imum 2'* lap at lateral and butt seams and sealed with lap cement. Finally, No. 16 ga. wire loops of copper clad or galvanized wire shall be tied over the roofing jacket on 4 centers.
Fittings should be insulated withMW-One Cement or asbestos cement, flush with adjacent covering and finished with pasted canvas jackets. For outdoor piping, finish with an additional 1. 4" wet coat of Thermotex 4<B" extending two inches over the adjacent roofing \ 00 200 300 400 jackets. Wet brush to a smooth finish.
Asbestos Sponge construction is sub*
MEAN TEMPERATURE F.
Flanged fittings and pipe fittings larger
stantial, yet flexible enough so that it
will not become damaged during shipment APPLICATION
than four inches should be insulated with a combination of 85% Magnesia
or installation. It can be removed from
blocks and cement.
pipe or equipment and reapplied without Pipe Covering: Sponge felt covering is
loss of material.
easily applied by placing the sectional Blocks: Usually held in place with 14-
USES
covering over pipe, making sure that the gauge or 16-gauge wire loops spaced lateral and end joints are tight and approximately 12" apart. Joints are
securing the canvas laps with cold pointed up with asbestos cement. Carey
For surfaces with temperatures up to700 water paste. If additional assurance is Fibrous Adhesive is sometimes used to
V F. Specifically recommended for use on desired metal bands may be applied at vibrating lines and underground steam butt joints and in the center of sections.
adhere blocks to surfaces as an extra securement. One-inch hexagonal wire
distribution lines because its structure Covering exposed to the weather should mesh is stretched tight over the blo.cks
is tough. Cylindrical pipe covering sec be protected with a roofing jacket, as a reinforcement when .'n asbestos
tions can be furnished for large pipe usually 45 lb. Surety. If roofing jacket cement finishing coat is required.
sizes.
Blocks and sheets are designed for use on stills, tanks, boilers and other large surfaces where the insulation must with stand extremely rough service.
SPECIFICATIONS
Pipe covering is regularly furnished with 3.5-ounce canvas to meet Federal Speci fication HH-l-561c, when so indicated on order. Heavier jackets can be fur nished, as can roofing jackets for out side service.
SIZES:
Blocks and Sheets-Standard length: 36". Standard thicknesses: 1", 1-1/4", 1-54", 1-3/4", 2", 2-1/2", 3". Standard widths: 6", 9", 12", 18", 24", 36".
Pipe Covering--Furnished in split cylindrical sections 36" long for pipe sizes up to 36''. Standard thicknesses: from 1" to 3-54".
Tough, rugged Carey Asbestos Sponge insulates and protects piping in Canada
Sugar Refining Company plant.
'
N- * A'
| industrial
FLEXIBLE TUBING INSULATION fejnsulation t
CAREY FLEXIBLE TUBING INSULA TION is e tough, flexible, polymeric material constructed of millions of uni form closed cells. It can be used on any line operating between 20 below 0F.
and 200F.
DESCRIPTION
Ci / Flexible Tubing Insulation is maae of Hycar man-made rubber, an ex tremely oil-resistant material. It was developed to overcome the loss in effi ciency which can occur with open cell (sponge rubber) tubing, i.e., when used as insulation on cold water lines, hot, humid weather may cause open cell tubing to absorb water vapor which condenses and destroys insulation efficiency. Carey p,-*xible Tubing Insulation prevents this
>Ie. Its millions of tiny cells are non connecting; each one sealed off ft* _ its neighbors. It is impervious to water vapor and will not lose its effi ciency due to moisture absorption. A highly efficient pipe insulation, it can be applied with remarkable speed and ease to copper tubing and iron pipe. It is so flexible that it can be bent, twisted and formed and yet so resilient that it so .s back to its original shape when PV a place. It is made in continuous lengths, in many wall thicknesses, and will withstand temperatures from minus 20F. to 200F.
FEATURES
The K factor of Carey Flexible Tubing Insulation is .26. 1/2*' wall tubing is recommended for severe conditions while thinner wails may be used under less severe conditions or where economy is of prime importance.
It resists deterioration and moisture absorption, so efficiency remains high in service.
The uniform closed cell structure seals out air and moisture. The result is a water vapor transmission rating of less than 0.1 PERM. Because of its excellent temperature resistance, Carey Flexible
'ng Insulation can be used to insulate carrying hot as well as cold water.
It -mS excellent weather-aging properties. Samples have been exposed in the Atlas Weatherometer for 100 hours (equal to 6 months to a year outdoor aging) with only barely visible cracking. The material is also resistant to the deteriorating action of Ozone.
Carey Flexible Tubing Insulation is flame-resistant and will not support com bustion. A standard test is to hold a sample over a 2** Bunsen Burner flame for 30 seconds. After removal from the flame the time of burning is noted -- less than i/2 minute by this test.
completely assembled, the tubing is split longitudinally, cut into proper lengths and snapped onto the lines. Cut seams are joined together with cement. In all cases, these same adhesives can be used to seal end joints and no other sundry material is required.
Carey Flexible Tubing Insulation is a strong, tough material. The tensile strength varies, depending on the density and cross section. Pieces of 1/2" cord gave tensiles of 150 PSI and elongation of 200% to 225% at break.
USES
Carey Flexible Tubing Insulation is recommended for insulation of dual tem perature lines carrying hot or chilled water from a central system to air con ditioning units in hotels* apartments and office buildings. Many of these lines are formed copper tubing and are difficult to insulate, even with semi-rigid materials. When Carey Flexible Tubing Insulation is used, job experience has shown laborsavings of 50% and higher in these applications.
Carey Flexible Tubing Insulation can be used to advantage on any line operating between 20 below 0F. and 200F. where flexibility, high insulating value, vapor resistance and ease of application are important.
APPLICATION
When applied to copper tubing before sweat fittings connections are made, the tubing is pushed back along the pipe and held back with clamps until the joint is soldered. The self-extinguishing proper ties of Carey Flexible Tubing Insulation made this time-saving application method feasible. Once the fittings have cooled, the clamps may be released and the tub ing slipped back to cover the fittings.
SPECIFICATIONS
Density.....................6-12/lbs./cu. ft. K Factor..................0.26 Water Absorption. . 10% max. Temperature Range -2(P F. to 200F. Flame Resistance. Will not support
combustion Weather Agin$ . . . Excellent Tensile Strength. . . 150 psi Fungus & Vermin
Resistance .... Excellent
2ASTM D1056-53 Method
Thermo! Conductivity at Various Temperatures
There are two practical methods of ap plying Carey Flexible Tubing Insulation. The faster and easier way is to slip the insulation on pipes or tubing as they are being installed. A factory-applied coat ing of talc on the inner surface minimizes resistance, and speeds slip-on applica tion. In cases where the piping has been
Application in close quarters is easily done by slipping the insulation on the tubing as it is being installed. A factory applied coating of talc on the inner surface mini mizes resistance.
/
r
v
( K.
THERMOGLAS PIPE COVERING
(industrial (insulation
DESCRIPTION
Thermoglas pipe covering is used on pipes having temperatures up to 350 F. It simply "snaps in place".
Unusual Permanence-will not sag, rot, mold, or otherwise decompose. Resists attack of most acids and alkalies, and is not corrosive to metals. Will not chip, flake, dent*, break or crumble, and is un affected by water and insects.
Thermoglas is also an excellent cold anc dual-temperature insulation when used with a vapor barrier jacket.
Available types of vapor barrier jacketing and weatherproof jacketing:
Thermoglas is exceptionally lightweight insulation composed of long, fine, blown glass fibers bonded with thermal-setting phenolic resin. It is a strong, semi-rigid and resilient insulation with no coarse fibers to irritate hands or skin.
FEATURES
Lightweight--weighs one-tenth to onefourth as much as other insulations...less weight on pipe supports.
Easy Application--practically a one-hand operation. Cuts application costs.
Very Low Moisture Vapor Pickup
Excellent Workability--cuts easily to fit valves and fittings.
USES
Thermoglas pipe covering is used for pipe temperatures up to 35(j F. It is recom mended for hot water and low-temperature steam piping in industrial plants, com mercial buildings and institutions. Ther moglas can be used as an outside layer over a high-temperature insulation.
Angier ior Dual Temperature Black Angier for Dual Temperature - White Foil Faced Flame Proof Kraft Jacket
Available Types of Weatherproof Jacket ing:
35-lb. Roofing Jacket 45-lb. Roofing Jacket 55-lb. Roofing Jacket
Available with Standard Weight 4-oz., 6oz., and 8-oz. canvas jackets.
SPECIFICATIONS
TABLE OF RECOMMENDED THICKNESSES* FOR INDUSTRIAL, COMMERCIAL, INSTITUTIONAL PIPING
Pipe Surface Temp. F.
Temp. Differ ence, F.
Pipe Site
Pipe Insulation Surface Temperature Under 100 F 80 F Ambient Still Air
150 200
250
300
350
70
120
170 220
270
Nom. Heat
Nom. Heat
Nom. Heat
Nom. Heat
Nom. Heat
Thick. Loss %Eff. Thick. Loss %Eff. Thick. Loss %Eff. Thick. Loss %Eff. Thick. Loss %Eff.
%
K 9 78.4
K 16 80.4
54 20 84.5 I
24 87.5 IK 28 89.2
1
K 12 77.2
54 17 83.3 1
21 86.8
1
28 87.4 IK 30 90.5
iy*
K 13 79.8
54 18 85.5 1
27 86.4 IK 26 90.9 IK 33 91.3
1'/:
K 16 78.1
54 22 84.8 1
27 87.9 IK 29 90.9 IK 34 92.2
2
K 17 80.6
54 25 85.5 1
32 88.5 IK 33 91.6 IK 43 92.0
2K
Vt 20 80.8
54 29 85.9 1
37 . 88.8 IK 42 91.0 2
45 93.0
3
K 27 78.7
54 36 85.3 1
43 88.9 IK 44 92.2 2
48 93.7
3K
Vt 30 79.1
54 40 85.8 1
41 90.8 IK 55 91.3 2
58 93.3
4
K 32 80.2
54 44 85.8 1
52 89.4 IK 54 92.5 2
57 94.1
4k
K 26 85.3
54 47 86.4 1
49 91.0 IK 66 91.7 2
68 93.6
5
K 39 80.0
54 53 86.3 IK 46 92.4 IK 64 92.7 2
68 94.2
6
A 48 78.9
54 62 86.1 IK 56 92.1 IK */S 92.6 2.
77 94.4
7
54 56 81.0 1
58 88.6 IK 61 92.5 IK 82 93.0 2
87 94.5
8
54 63 78.6 1
62 89.2 IK 68 92.5 IK 91 93.1 2
95 94.6
9
54 64 80.5 1
69 89.1
IK 75 92.6
2
76 94.8
2
100 94.9
10
54 80 77.9 1
80 88.7 IK 80 92.9 2
87 94.6
2
110 94.9
11
1
44 85.0
1
80 89.7 IK 86 92.9 2
94 94.6
2
120 94.9
12
1
48 88.7
1
86 89.6 IK 94 92.9 2
100 94.6
3
95 96.3
14
1
57 87.6
1
105 88.5
IK no 92.3
2
115 94.5
3
105 96.2
15
1
61 87.6
1
110 88.5
IK 115 92.4
2
120 94.5
3
110 96.2
16
1
65 87.6
1
115 88.5
IK 125 92.4
2
130 94.5
3
120 96.2
17
1
69 87.6
1
125 88.4
IK 130 92.4
2
135 94.5
3
125 96.2
18
1
72 87.6
1
130 88.4
IK 135 92.4
2
145 94.5
3
130 96.3
19
1
76 87.6
1
140 88.4
IK 145 92.4
2
150 94.5
3
140 96.3
20
1
80 87.6
1
145 88.4
IK 150 92.4
2
160 94.5
3
145 96.3
21
1
84 87.6
1
150 88.4
IK 160 92.4
2
165 94.5
3
150 96.?
22
1
88 87.6
1
160 88.4
IK 165 92.4
2
175 94.5
3
155 96.3
23
1
91 87.6
1
165 88.4
IK 170 92.4
2
180 94.5
3
165 96.3
24
1
95 87.6
1
175 88.4
IK 180 92.4
2
185 94.5
3
170 96.3
* Where maximum efficiency is of primary importance
Carey Industrial Insulation
Thermoglas Pipe Covering
TABLE OF RECOMMENDED THICKNESSES- FOR HOT WATER AND LOW-PRESSURE STEAM Pipe Insulation Surface Temperature Under 120 F 80 F Ambient Still .Air
Pipe Surface Temp--F
Pipe Si2e--In.
v< 1 1-4 1-54 2
2-4 3 3-4
ru
5 6 ( 8 9
10 11 12
150F
A on. Thick. Inches
%Eff.
X 78.2 X 77.0
79.6 X 77.7 X 80.2
4 80.5 Vi 79.2 Vi 79.2 Vi 80.0 Vi 85.4
Vi 80.2 X 78.7 X 78.6 Vi 78.3
4 80.4
% 77.9 1 88.8 1 88.8
200F
A'om. Truck. /nches
% Eff.
X 80.4 V 79.2 X 81.8 Vi 79.9 Vi 81.8
Vi 82.2 Vi 80.8 Vi 80.8 Vi 81.5 Vi 86.5
Vi 81.8 Vi 80.4 .'2 80.5
4 80.0
X 81.7
X 79.6 89.7 89.6
250F
A'om. Thick. Inches
% Eff.
X 81.9 Vi 80.6 X 82.9 X 81.0 X 83.2
X 83.3 Vi 82.0 X. 82.0 Vi 82.6 X 87.4
X 83.0 X 81.7 X 81.6
89.8 89.9
1 89.5 90.2 90.2
300F
A'om. Thick. Inches
55 Eff.
X 82.9 X 81.4 X 83.9 x 86.6 % 87.2
X 87.4
% 87.0
3/ /4
87.6
% 87.5
X 88.2
%/ 4
88.0
3/ /4
87.8
1 90.0
1 90.6
90.5
90.1 1 90.8
90.8
350F
A om. Thick. Inches
% Eff.
y/4 86.1
X 85.9
3'4 87.8
X 87.1
3/ /4
87.7
X 87.9 1 90.0 1 91.7 1 90.6 1 92.0
1 90.6 1 90.3 1 90.4 1 90.9
1 90.9
1 90.5 1 91.4 1 91.4
* Where low initial investment is of primary importance.
TABLE OF RECOMMENDED THICKNESSES* FOR COLD PIPING AND DUAL-TEMP. SERVICE
THERMAL CONDUCTIVITY
.40
T emperature Up to 14"
Pipe Sizes
2" - 3X* 4" 6"
7" - 10"
11" - 24"
Chilled Water Ice Water Brine Special Brine
.Above 50F 50F to 35F 34F to OF
OF to -30F
1"
w/r
2" 2-4"
1"
1-4" 2-4" 2-4"
1" 1-4"
2-4" 3"
1"
1-4" 2-4" 3"
1"
1*4" 2-4" 3-4"
6 .20
^
Based on thicknesses needed to prevent condensation on pipes exposed to ambient conditions of 90 F. and 90fe relative
humidity.
APPLICATION
Thermoglas pipe covering is sawed on one side only. To apply, simply pull the section apart at the seam, slip one end over the pipe and run hand up seam so that section snaps in place. Seams can
be closed light with pressure-sensitive mastic tape, staples, siring, canvas and paste, metal bands or other standard fastenings.
Thermoglas can be painted if desired.
.to
100 200 MEAN TEMPERATURE F.
300
Sizes: Thermoglas is available in onepiece sections made in 3-foot lengths for small sizes. Medium and large sections are furnished in 6-foot lengths. Canvas jackets in several weights are available.
HAIR FELT INSULATION
industrial insulation
DESCRIPTION
TABLE OF WEIGHTS
Weight per Square Foot--Ounces
Standard Hair Felt (Nos. 300 and 301)-- Cattle hair felted and pressed to uniform thickness by steam-heated platens. This type of insulation is distinguished by waffle pattern on one surface. No. 301 is 10% lighter than No. 300.
Punched Hair Felt (No. 302)^Cattle hair, felted but not pressed under steam plat ens. Punched with needles to interlace the hairs and give strength to the felt.
Hair and Jute Felt (No. 303)--Corabinap tion of jute fibre and cattle hair, felted and punched to interlace fibres.
USES
Hair Felt is used for insulating coldwater and ice-water fittings, and as a "built-up'* insulation on refrigeration pipes and equipment. Particularly suited for covering irregular shapes.
SPECIFICATIONS
Thermal conductivity: 0.24.
RECOMMENDED THICKNESS
Temperature Range
50 to 15 to
0 to
-20 to -40 to -60 to -80 to
-100 to -120 to
63 F.
50 5
0 -20 -40 -60 -80
100
Multi-Layer Thickness
1" 2" 3" 4" 5" 6" 7" 8" 9"
Thickness-in.
1/4 1/2 3/4
1 1-1/2
2
No. 300
4 6-1/4 84/2 11 16 21
No. 301
4 6 8 10 14 18
No. 302
4 6 4/4 8 4/2 11 16 21
No. 305
.. -- -- 000 --
Hot Asphalt Method: First a layer of dry 15-Ib. Feltex Roofing Paper shall be applied to the pipe and secured by a spiral wrapping of jute twine. Then, al ternate layers of \*y thick Hairfelt and 15 -lb. Feltex Roofing are built up to the desired thickness. Each layer of Hairfelt and Feltex shall be heavily coated with hot asphalt and placed on the pipe while hot. Layer of Hairfelt shall be addition ally secured to the pipe with a spiral wrapping of jute twine on 1'* spacings. Canvas, coated with hot asphalt, should be used to seal irregular surfaces. The last layer of Hairfelt is finished with two layers of Feltex applied with hot asphalt, followed by rosin steed paper and canvas jacket.
Insulating Membrane Tape Method: Alter nate layers of Hairfelt and Insulating Tape shall be built up to the desired thickness. The Hairfelt shall be cut to the proper length and placed on the pipe dry. Hairfelt to be secured in place with a spiral wrapping of jute twine or light gauge soft annealed wire on 1** spacings. Over each layer of Hairfelt a spiral
wrapping of insulation shall be applied lapping the tape at least enough to give double coverage. Each layer of tape shall be painted with a heavy coat of Asphalt sealing paint. Finally, the covering shall be finished with a heavy rosin sized paper and a canvas jacket.
Fittings and valves can be insulated in one of the two methods outlined above. In cutting Hairfelt for irregular surfaces it is important that proper cuts are made to eliminate any overlapping or bulges in the insulation. To insure good results Hairfelt should be applied with all joints staggered. At fittings, Hairfelt should be stepped back 2" from the end of the previous layer. To insulate the fittings the Hairfelt should be cut to fill in these "step-backs'* to make the desired broken joint construction. When insulating for below-freezing temperatures, hanger rods must be insulated a minimum of twice the thickness of the required insulation.
Note: Refrigeration insulation should be applied only by mechanics skilled in this type work.
SIZES AND WEIGHTS No. 300: Standard Hair Felt, standard weight, available in rolls 3' x 50' and 6' x 50'.
No. 301: Standard Hair Felt, light weight, available in rolls 3' x 50* and 6' x 50'.
No. 302: Punched Hair Felt, standard weight, available in rolls 3* x 50* and 6' x 50'.
No. 305: Punched Hair and Jute, light weight, available in rolls 6* x 50*.
APPLICATION
Applying Hairfelt Covering on surfaces which operate at extremely cold tempera tures places the material under very severe conditions and care must be taken to see that all surfaces are dry before insulation is installed.
Hairfelt can be applied in alternate methods.
Carey Hair Felt insulation shows why it's particularly recommended for covering irregular shapes. Hair Felt is also used as a "built-up" insulation on refrigeration pipes and equipment.
MW-50 INSULATING CEMENT
industrial
gnsulation
USES
MW-50 Cement is an excellent monolithic insulation for valves, fittings, expansion joints, heaters, exchangers, access doors, water tube boiler walls, tanks, stills, drumheads and other heated equipment operating at temperatures up to 1600 F. It is particularly recommended for ir regular surfaces due to ease of applica tion. MW-50 Cement bonds firmly to metal, masonry and all block insulations.
SPECIFICATIONS
RECOMMENDED THICKNESS
Temp. -- 0 F
ThicknessInches
Cross section through MW-50 Cement showing clean, insulating fiber nodules or pellets bonded only at their surfaces. These numerous and minute air films and air spaces provide high insulation value. MW-50 Cement can be used for temperatures up to 1600 F.
DESCRIPTION
MW-50 Cement is a complete insulating material in itself. Special MW-50 nodular mineral fibers are combined with bonding materials, -asbestos fiber and a rust inhibitor to produce a mixture with ex cellent physical and thermal properties.
100 to 225 225 to 325 325 to 425 425 to 525 525 to 625 625 to 727 725 to 825 825 to 925 925 to 1000 Over 1000
1 1-1/2 2 2-1/2 3
3-1/2
4
4-1/2
5 Consult Carey
Packaging: MW-50 is furnished in 5<Mb. and 100-lb. paper bags.
MW-^0 Cement in use at Kansas City Power and Light Co., Kansas City, Mo.. Pipes carry saturated steam at a temper ature of 500 to air heaters. Insulation
is Carey 85% Magnesia.
THERMAL CONDUCTIVITY
FEATURES
High Insulation Value--More than double
that of ordinary asbestos cements. MW-50
mineral fiber has remarkably low heat
conductivity.
_
Negligible Shrinkage--Fibrous toughness minimizes cracking and shrinkage in drying.
Highly Adhesive--MW-50 adheres to both warm and cold surfaces.
Economical--One-inch coat of MW-50 Cement insulates 4s well as a two- or three-inch coat of ordinary asbestos cement. MW-50 goes further, too. One 50-pound bag covers approximately 25 sq. ft. to one-inch thickness. A 100pound bag of ordinary asbestos cement covers only about 17 sq. ft. to same thickness.
For permanent weather protection, apply Thermotex-B or Insulation Seal over wire mesh or. Fiberflex.
MEAN TEMPERATURE P.
APPLICATION
Add water to MW-50 Cement and mix to a stiff mortar consistency, (This wet mixture can be kept for reuse.) We recom mend troweling on layers of approximately 3/4-inch thickness, one at a time. Each layer should be thoroughly dry before successive layers are applied. When layers over 3/4" thick are applied.
poultry wire reinforcement should be in stalled between each layer. Even for nor ma! layer thickness, we recommend one layer of poultry wire before the final coat on large surfaces.
Leave all coats with a rough surface, ex cept the last coat which should be troweled smooth. Paint final coat, if desired.
MW-ONE INSULATING CEMENT
industrial insulation
SPECIFICATIONS
Finished coat varies from 1/4** to 1/2** thick. Figure MW-One as a part of total insulation thickness. When making up fittings or insulating irregular surfaces
use 1/2** thickness for each 100 F., plus 1/2" additional thickness.
Packaging: MW-One is packaged 50 pounds per multi-wall Kraft bag. Mixing instructions are printed on each bag.
THERMAL CONDUCTIVITY
$ K
MW-One Insulating Cement, in 50 pound bags, is available only in white lor temperatures to 1000 F.
DESCRIPTION
Carey mineral wool pellets and other ingredients (including rust inhibitor) are combined in MW-One Insulating Cement to form a monolithic, all-purpose, fast setting finish cement that insulates as well as protects, giving a white surface.
FEATURES
. Quick, easy, single-coat applicationsaves valuable time and dollars.
. Tough, smooth surface-^an be painted.
. Negligible shrinkage (Max. 1%)--no hairline cracks.
. Fast setting--two to three hours.
. Rust inhibilive, noncorrosive.
. Fire-resistant, noncombustible.
. Excellent cohesion--to all types of insulation.
. Many uses inside and out.
. Good workability--fast wetting, easy to mix and spread. Very plastic under trowel.
. Water resistant.
USES
For valves, fittings, tanks, ovens, hot air ducts. MW-One can be applied directly over any insulation, or it can be used as a finishing cement for Carey MW-50,
0
200
400
600
MEAN TEMPBUTURE eF.
aoo 1000
Carey Industrial Insulation
MW-One Insulating Cement
PLICATION
Mix Ratio: 50 pounds MW-One to 8 or 9 gallons water. Dry mix the material, turning the bag end for end several times to eliminate segregation acquired in shipment on storage. MW-One readily combines with water but does not become saturated. Thus MW-One is easily trowelable and retains its high insulating qualities.
Numerous small batches are best and eliminate waste. Clean and rinse the mix box before each batch. Keep the mechanic supplied steadily during application, using sufficient number of clean pails. Surface to receive cement should be free from all dirt, dust, rust, grease, paint or other foreign matter.
f One Cement should be applied to ^...m surfaces--not hot. After initial set period of 2 - 3 hours, surface temperature can be raised without affecting cement. Don'* attempt to salvage unused material that has been mixed for the initial set period of time, or add to a previously mixed batch.
In applying, hard trowel the material in ^er to secure a good, firm "key" with
blocks or one-inch mesh reinforce . Then continue to apply the ma i. j! to the specified thickness required in one coat. Dip trowel frequently in clean water to speed'application.
MW-One cement covers approximately MW-One has a variety of uses, inside and out. Recommended for valves, fit150 sq. ft., 1/4" thick, per 100 lbs. tings, tanks, ovens, hot air ducts where temperatures do not exceed 1000.
CEMENTS INSULATING AND FINISHING
--- ----------rasr-w,-
industrial insulation
INSULATING CEMENT
No. 707 Asbestos Cement: This is a long fiber grade having excellent in sulating value. It is recommended for covering fittings, pointing up blocks and pipe covering, and for a finish coat over block work where an exceptionally smooth finish is not required.
LF-20 Cement should be mixed with water and applied in layers 1/4" to 1/2" thick. The first layer should be reinforced with hexagonal wire mesh. This cement is intended for finishing only where specifications call for long fiber cement.
Its conductivity at 100 F. is 1.6; at 300 F.t 1.8. '
LF-20 meets Military Specification \1ILC-2908. Furnished in 50 lb. paper bags and 100 lb. burlap bags.
No. 100 Asbestos Cement (Hard Finish): Composed of asbestos fibers and bonding clays,. No. 100 Cement is specifically designed to give a hard, smooth white finish oveT block work or other insulation. It should be used only for finish work. No. 100 Cement is mixed with water and trowel-applied in approximately 1/4" layers. The first layer should be rein forced with hexagonal wire mesh.
covers approximately 20 sq. ft.. 1" thick, per 100 lbs. No. 100 Cement is furnished in 50 lb. paper bags and 100 lb. burlap bags. Meets Specification AMSC 35 Type PI.
No. 303 Asbestos Cement (General L'tilitv h Composed of asbestos fibers and bonding clays. No. 303 Cement is a general utility cement for finishing and pointing up fittings. It sticks to all surfaces and finishes medium hard.
This cement is mixed with water and trowel-applied in approximately 1 4" layers. The first layer should be rein forced with hexagonal wire mesh when this cement is used over other insulation.
Conductivity at 100 F. is 1.4; at 300 F., 1.9. It covers approximately 10 sq. ft., 1" thick, per 100 lbs. No. 303 Cement is furnished in 50 lb. paper bags and 100 lb. burlap bags.
This cement has a minimum of shrinkage. No government specification is issued Conductivity at 100 F. is 1.30. It for No. 303 Cement.
This cement is reasonably hard, has superior sticking characteristics, and is effective at temperatures up to 750 F. Its covering capacity is approximately 22 sq. ft., 1" thick, per 100 lbs. Con ductivity at 100 F. is 1.00; at 500 F., 1.34.
No. 707 Cement is furnished in 50 and 100 pound bags.
FINISHING CEMENT
LF-20 Asbestos Cement (Long Fiber): This Cement is composed of long asbestos fibers and bonding clays. It is a medium hard finish cement for final surfacing of insulation where expansion strains are severe, such as over boiler water walls. This cement trowels to a smooth white finish and covers approxi mately 20 sq. ft., 1" thick, per 100 lbs.
Carey finishing cements trowel to a smooth, white finish. Improve the appearance of every installation.
Carey No. 100 finishing cement provides a hard, smooth surface over block work and other types of insulation.
CEMENTS BONDING AND REFRACTORY
ea
industrial insulation
t JDING CEMENT
Fibrous Adhesive (Bonding): Composed of asbestos fibers, silicate of soda and filler materials. Fibrous Adhesive is a fibrous plastic cement of thin troweling or brushing consistency* It is designed for laying up insulating blocks, and it makes a very strong heatproof bond that is unaffected by temperatures up to 800 F.
Fibrous Adhesive is applied with trowel or brush to approximately 1/8'*thickness, h can be applied either in spots or over the entire surface to be insulated. It can be applied on cold or warm surfaces, but not at temperatures above 200 F. After application it should not be heated over 200 F. for three or four days.
C'T its must be kept tightly sealed. In pav ily used containers, a thin film of water should be kept on the surface of the adhesive. '
One gallon covers 25 to 30 sq. ft. of block insulation to approximately 1/8** thickness. Fibrous Adhesive is furnished in 1-gal. pails weighing approximately 12 lbs. gross; 5-gal. pails weighing ap proximately 67 lbs. gross; 55-gal. barrels ' ing approximately 670 lbs. gross.
M< Navy Specification 52-C-22 (INT).
REFRACTORY CEMENT
Carey Hi-Temp blocks installed at Ford Motor Company, Detroit, are finished with 3/4" thick Vitricel cement inside boiler breeching.
Vitricel Cement (Refractory Finishing): Composed of asbestos fibers and bonding materials, Vitricel Cement is a dry, semi-refractory hydraulic setting cement for -nperatures up to 1900 F. It is de^, .d for pointing up joints and cracks in stack and breeching lining, covering metal parts exposed to hot corrosive gases, and surfacing block insulation in stalled inside breechings, ducts, econ omizers. Vitricel Cement resists moisture
and has a very low drying and heat shrinkage.
This cement is mixed with water and applied in layers approximately 1/2** thick. The first layer should be applied over reinforcing mesh, preferably stucco metal lath. Where two coats are required, apply 10 to 12 sq. ft. of the first coat and follow immediately with a second coat before the first one dries. Mix only
quantities that can be used within onehalf hour. Apply immediately after mixing. Packages must be stored under conditions as dry as for Portland Cement.
Vitricel Cement covers approximately 17 sq. ft., 1** thick, per 100 lbs. It is furnished in 50-lb. paper bags.
No government specification is issued for Vitricel Cement.
INSULATION EMULSIONS THERMOTEX B,
No. 51 and No. 228 EMULSIONS
industrial
Einsulation
aKauttMitfBssMK&iautoim
Insulation on vacuum towers and piping is waterproofed with 1/4-inch coat of Thermotex-B.
THERMOTEX B
DESCRIPTION
Thermotex-B is a combination of asbes tos fibres, emulsified asphalt and mineral fillers. It forms a cold plastic water proof coating, which is applied by trowel in one or more coats.
FEATURES .
Excellent elasticity -- minimizes sur face cracking from temperature changes.
Non-burning, fire-resistant.
Shipped ready-to-use -- eliminates onthe-job mixing.
Good coverage -- 100 pounds covers approximately 55 square feet, full 1/4inch thick wet or 1/8-inch thick dry.
Dries quickly.
Requires no painting.
USES
Thermotex-B is recommended as a dura ble, waterproof coating for insulation on hot equipment, ducts, vessels, breech ings, tanks, towers, heat exchangers and fittings that are subjected to weather con ditions. It is especially suited for oil and chemical plant use because it withstands acid and alkaline conditions and can be installed over insulation that is not com pletely dry. Thermotex-B is a breathingtype coating. After application over moist insulation, Thermotex-B allows the trapped water vapor to escape, while remaining impervious to surface water.
Thermotex-B is not recommended for equipment operating at temperatures lower than ambient. When the insulated surface temperature is lower than the dew point of the surrounding air, water vapor will form on the surface. This condensation is like ly to penetrate the insulation and cause rusting and deterioration. A cut-back type of weatherproof material should be used on all equipment operating below the dew point of the surrounding air.
The following are a few advantages of an emulsion such as Thermotex-B over cut-back materials: 1. Will not blister. 2. Will not run or sag as easily as cut
backs. 3. No odor. 4. Non-flammable. 5. Can be applied over a moist surface.
SPECIFICATIONS
Meets Specification AMSC-35 Type B3.
Packaging: Thermotex-B is furnished in 45-lb. pails, 270-lb. drums, 470-lb. drums. Plastic liner protects Thermotex-B from electro-chemical reaction in drum to as sure proper consistency. After drum is open, liner can be re-tied to preserve unused Thermotex-B.
Handling: Thermotex-B should be protect ed against freezing during storage and during application.
APPLICATION
Thermotex-B should not be applied during wet weather or when temperatures are freezing or near freezing. Temperatures must remain above freezing until Thermotex-B coating is thoroughly dry.
When applying Thermotex-B over a nonporous surface such as steel, a prime coat of Carey Ebontex Primer should be spread thinly over the surface. This should be followed immediately with Thermotex-B.
Primer is not required when Thermotex-B is to be applied over asbestos cement or other absorptive insulations. One-inch mesh poultry wire should be secured over the insulated surface. A skin coat is usually troweled on the wire, followed immediately with the main coat of 1/4" thickness. (After drying, the main coat will shrink to about 1/8*' thickness.)
While troweling, brush with water to ob tain final smooth surface. For a hard surface, mix two or three parts of clean sand with one part of Thermotex-B.
NO. 51 EMULSION
DESCRIPTION
An odorless, non-inflammable clay tvo< emulsified asphalt composed of asphalt water and bentonite clay.
CONSISTENCY:
Troweling. If necessary to thin, ad< small amount of cool, clean water stirring rapidly.
USES
1. As a prime and bond coat for insula tion and cold storage vault and othe low temperature insulated construction
2. As a bond coat for cementing layer: for vapor barrier and aluminum foi to walls and ceilings. Mixes well witi Asbestos Fibre and sand to make "os the job" finished coats.
3. Can be used to make asphaltic morta by mixing 6 parts of No. 51 Emulsion 1 part of Portland Cement and 1 par water.
COVERAGE
1 gallon per 20-25 sq. ft. for bonding insulation.
1 gallon per 100 sq. ft. for priming.
1 gallon per 50 sq. ft. for bonding vapoi barrier sheets.
Must be stored at temperatures above freezing.
NO. 228 FIBRATED EMULSION
DESCRIPTION
An odorless, non-inflammable composi tion of bentonite clay type emulsiiied asphalt .and asbestos fibre similar to Thermotex-B.
CONSISTENCY
Trowel.
USES
1. Weather proof coating to protect insu lation exposed to weather, chemical fumes and liquids, applied to win mesh stretched over insulation.
2. On insulated air conditioning ducts as a coating or for `'running the
seams" on rigid duct insulation.
3. Can be used as a protective damp proofing coating on foundation walls and perimeter insulation.
4. Mastic finish coat in cold storage vault construction.
COVERAGE
Head of vacuum distillation unit has 1 gallon per 6 sq. ft. produces a dry
Thermotex-B applied over insulation.
thickness of 1/8".
CORK-COTE MASTIC
Industrial insulation
aulating and weather-resistant coating applied directly to the primed metal surface. Can be troweled, brushed or sprayed.
DESCRIPTION
/",*'rey Cork * Cote Mastic is an asphalt * mastic containing a high percentage -anulated cork. It may be applied
w*n a trowel, brush or spray equipment. It is normally applied, to a thickness of H' or H The mastic film protects equipment from weather and corrosion and decreases the possibility of conden sation forming on the equipment. It also serves as a sound-deadener on ducts and
' ->r equipment.
Carey Cork - Cote Mastic being applied on a well water line at American Oil Com pany's plant in Destrehan, Louisiana.
USES
,
Carey Cork Cote Mastic is used by the refinery, chemical and petro-chemical in dustries as an anti-sweat insulating and weather-resistant coating applied directly to the primed metal surface. It may be used on fractionation towers, oil or water storage tanks, duct and pipes, or on other equipment where an inexpensive coating is needed to help reduce con densation, help prevent corrosion and protect against weather.
PHYSICAL PROPERTIES
Linear Shrinkage: None '"hickness Shrinkage: 10--20%
'erages: ich .... 12 gals per 100 sq. ft. h mch .... 20 gals per 100 sq. ft. Weight Per Gallon: 6.4 lbs. Flashpoint: 100 F.
APPLICATION
Temperature of the material during ap plication should be between 50 F. and 80 F. For spray application the oper ating air pressure on the material should be 20 to 50 lbs. A desired thickness of application must be accomplished in one application.
LIMITATIONS
Storage for periods more than 90 days will cause difficulty in spray application as the consistency increases slowly in storage. The container should be covered when not in use and kept away from open flame or heat. Ventilation should be pro vided when working in closed spaces to remove fumes.
Special mastic film protects equipment from weather and corrosion and de creases the possibility of condensation damage.
40
INSULATION SEAL
^industrial ^insulation
DESCRIPTION
Insulation Seal is a ready mixed asbestos fibrated bituminous mastic.Itis especial ly compounded for cold application over most types of insulating materials. It protects the insulation against damage and loss of efficiency by the penetration of water and water vapor. Insulation Seal is made in spray (No. 820) consistency or trowel (No. 830) consistency.
USES
Insulation Seal can be used on pipes, curved and flat surfaces of all kinds. It will hold its bond on horizontal, vertical, sloped or inverted surfaces, insulation Seal is designed for application over in* sulation such as 85% magnesia, asbestos cement, rock wool base cements, cellu lar glass, fibre-glass, mineral wool blan kets. It remains flexible and will with stand moderate expansion and contraction without cracking on interior or exterior surfaces.
Insulation Seal is specially recommended for (1) systems operating at temperatures below dew point, (2) dual temperature sys tems, and (3) systems subject to long shutdown periods. It should not be ap plied to surfaces subject to temperatures in excess of 250 F.
recommend spraying or troweling a first coat using about 3 to 4 gallons per 100 square feet. Then, a layer of Glass-Fab (asphalt bonded glass fabric) should be imbedded in the Insulation Seal. The second coat should be appliedusing about 3 to 4 gallons per 100 square feet.
Carey Insulation Seal starts to set im mediately after application. It dries uni formly throughout and becomes a tough, firm plastic film in 9 to 10 days on in door installations. Outdoor installations
may take more or less time, dependin. upon weather conditions.
Caution: Open fires or welding shouh not be permitted in the area while coat ing is being applied or drying. Do no use solvents for thinning. For ease o application the best workable temperatur range is 50 F. to 100 F.t hence it it advantageous to store in warm room dur ing cold weather. Do not heat the con lainer above 100 F.
8ths
16ths
FILM THICKNESS AND COVERAGE
Approximate
Square
Feet per
32ds
64ths
Gallon
Approximate G allons per
100 Sq. Ft.
1 103.00
12
51.2
3 35.4
1 24
25.6
5 20.5
36
17.1
7 14.7
0.97 1.95 2.82 3.90 4.87 5.84 6.81
12 4 8 9
5 10 11
3 6 12 13
7 14
15
12.8 11.4 10.3
9.34 8.54 7.87 7.35
6.85
*
7.79 8.76 9.74 10.70 11.70 12.7 13.6 14.6
SPECIFICATIONS
Laboratory tests reveal that Insulation Seal is an excellent moisture barrier. Its penetrative moisture vapor per 24 hours per square foot equals only 0.0001 ounce of water. Thickness will shrink 10% to 12% in drying (due to loss of solvents), but there is no lineal shrinkage. One gallon covers about 13 square feet of surface to a finished 1/8-inch thickness.
Packaging: Insulation Seal is packaged in 54-gal. drums, 5-gal. pails, 1-gal. cans.
APPLICATION
All surfaces to be coated with Insulation Seal should be free of moisture, dirt, oil, rust and other foreign matter. During ap plication, temperature should not be above 130 F. for outdoor equipment, and not above 100 F. for indoor equipment. Best results are obtained when surround ing air temperature is between 50 F. and 100 F. Below-freezing applications can be made if surface temperatures are heated to prevent frost.
24
8 16
17
9 18
19
5 10 20
21
11 22
23
6.41 6.02 5.68 5.40
5.13 4.88 4.65 4.41
3 6 12 24 25
13 26 27
7 14 28 29
15 30 31
4-27 4.10 3.94 3.80 3.66 3.53 3.42 3.31
4 8 16 32
3.20
Note: Shrinkage of 25% can be estimated to obtain dry film thickness.
15.6 16.6 17.6 18.5 19.5 20.5 21.5 22.4
23.4 24.4 25.4 26.3 27.3 2 8.3 70.? 30.2
31.2
Fittings of dual temperature systems should be built up with layers of hairfelt and insulating tape and then coated with Insulation Seal.
When applying Insulation Seal over 85% Spray application of Insulation Seal on Finished breeching duct at TVA stean
Magnesia blocks and pipe covering, we outside breeching duct.
plant, Paducah, Kentucky.
BTU CEMENT
-f
industrial Insulation
D-jCRIPTION
Carey BTU Cement is a ready mixed asbestos fibrated bituminous mastic of a troweling consistency. It is especially compounded for cold application to ex terior surfaces of porous masonry walls. It produces a firm, tough, air-impervious plastic film which effects an air-tight seal, preventing infiltration of cold air through mortar joints, porous masonry and structural cracks.
USES
BTU Cement can increase boiler effi ciency and save as much as 10% on fuel bills when it is used for sealing the out side walls of brick boiler settings. It
/
can be used in power plants, boiler rooms, factories, apartments, hotels and institutional buildings.
SPECIFICATIONS
Laboratory tests show penetrative mois ture vapor per 24 hours per square foot equals 0.0001 ounce of water. Coverage--40 lbs. to 100 sq. ft., 1/16inch thick coating. We recommend a heavier coating up to 1/8 inch thick for old and very porous settings.
APPLICATION
Note: Do not use solvents for thinning. For ease of application the best workable
temperature range is 50 F. to 100 F., hence it is advantageous to store in warm room during cold weather. Do not heat container above 100 F.
Clean brick or masonry with a stiff broom or wire brush. If necessary, point up ail badly defective mortar joints with fresh mortar. Trowel BTU Cement well into all mortar joints and cracks. Point up care fully around cleaning doors, drum heads and openings. During application of the coating, the surface temperature should not be above 130 F. for outdoor equip ment and not above 100 F. for indoor equipment.
Caution: Open fires or welding should not be permitted in the area while coat ing is being applied or drying.
FIRECLAD JACKETING
Industrial insulation
SPECIFICATIONS
PHYSICAL PROPERTIES
PRODLCT
CAREY FIRECLAP
Weight Per Roll 108 sq. ft.
Approx. 50 lbs.
Approx. 50 lbs.
Tensile Strength, Lb.
With
49 87
Across
33
52
Tear Strength, W. Grams
1564
3200 plus
Pliability on Mandrel at 77 F. Cracks, cm. Passes, cm.
6 7
5 6
Wire Cutting Test Time to make 3** cut
41*27"
240*00*' plus
10 lb. weight, No. 18 wire ,
Carey Fireclad is a durable, weatherresistant jacketing specifically designed Match Test
7 drops
No drops
for the protection of outdoor insulated
pipe lines where the danger of fire must " Product "A** -- A jacketing widely used and generally considered as being most
be minimized. Ordinary roofing jackets
highly fire-resistant.
are not satisfactory, because they burn,
spread fire, and drip asphalt, which furth Packaging: Carey Fireclad comes in rolls lateral laps. On horizontal pipes, the
er contributes to combustion.
38" wide by 34*6" long, containing 108 laps should be located on the side of the
DESCRIPTION
Carey Fireclad consists of a tough, sub
square feet; and weighs approximately
50 lbs. per roll. When in storage, keep in dry place. Stack on end not over three rolls high.
pipe, turned downward. The jacket mav be held securely in place with rings of
No. 16 ga. copper weld wire or strapping on not greater than 4 to 6" centers --
stantia] sheet of asphalt saturated as bestos felt, over which is cemented on one side an unsaturated asbestos sheet. The complete sheet is reinforced with a fabric of tough, flexible glass threads. This construction combines flexibility with very high tensile strength and ex
APPLICATION
Carey Fireclad Jacketing should be ap plied with the white side out on all straight runs of pipe or expansion bends with at least 3-inch circumferential and
with one wire ring placed over each cir cumferential lap. No lap cement should be used.
In cool weather (below 50 F.) store overnight in a warm place before unroll ing.
tremely great resistance to tearing and
cutting from wire or strap fastenings. It
offers many "plus'* advantages as jacket
ing for outdoor insulated pipe lines.
.
USES
Carey Fireclad is recommended for use in the process industries and in oil re fineries, where it affords maximum re sistance to the spread of fire -- and further protects the insulated surface from weather damage.
FEATURES
. Will not drip asphalt in the presence of fire nor support combustion.
. Water-repellent white surface assures long life, maximum efficiency.
. Greater width reduces labor cost -- means fewer application joints.
. Will not crack when applied over small size pipe covering.
. High tensile strength.
. Reinforced with a fabric of tough, flex Carey Fireclad is widely used in oil refineries. Resists fire, protects insulated
ible glass threads.
surface from weather damage.
'
WEATHERPROOF JACKETING MATERIALS
industrial i linsulation [
ASBESTOS ROOFING FELT
An excellent uncoated asbestos roofing for jacketing high temperature insulated pipe lines where high temperatures may cause running and dripping of a coated roofing. Consists of 2 asphalt saturated asbestos sheets combined with asphalt. Surfaces are black. Has good flexibility to conform to small radius curvatures.
Carries Underwriters* Class "C** label.
Weight -- 45 or 55 lbs. per square.
Furnished in rolls 36 in. wide containing ^IOR sq. ft. (one square).
SATURATED ASBESTOS ROOFING FELT
An asphalt saturated asbestos felt rec ommended for underground pipe cover* ings. The felt weighs approximately 15 lb. per 100 sq. ft. A double wrap ''ly construction is recommended. Is
available in 20 lb. per 100 sq. ft. ht for application in one layer on the job. Furnished in rolls of 324 sq. ft.
Carey Roofing jacket Covering shown on outdoor pipe lines at Houston, Texas Power and Electric Corp. plant.
These felts can be factory applied to Asbestos Sponge, Careycel, Impervo and Protecto coverings. They can be fur* nished with, but not applied to, 85% Magnesia and Alltemp. 6** wide collars
covering butt joints and waterproof 'Cw^ient and wire for application will be supplied in each case.
15 lb. Felt meets:
'
Federal Specification HH-F-185 Class
A Type 11.
Navy Specification 7 Yg-AA-15. 20 lb. Felt meets:
Federal Specification HH-F-182
Class A.
Navy Specification 7 Yg-AA-20.
ORGANIC ROOFING JACKET COVERINGS
For outdoor pipes. Prepared roofing jackets attached to pipe coverings at the factory are the least expensive form of waterproofing. MuIti*Ply, Asbestos* Sponge, Careycel, Impervo and Protecto coverings can be furnished with such roofing jackets attached, including 6*in. wide collars for covering butt joints, and waterproof cement and wire for appli* cation. These jackets can be furnished with, but not attached to, 85% Magnesia
and Alltemp coverings. For outdoor ex* posed pipes Carey Surety Roofing jacket* ed coverings are regularly supplied. For pipes running in closed conduits under* ground, double layer Saturatea Asbestos Roofing jackets are recommended.
All weatherproof jacketing materials can be furnished in bulk unattached to pipe covering, with accessories for applying.
ASBESTOS MILLBOARD
industrial insulation
USES
SPECIFICATIONS
Asbestos Millboard is used extensively in the electric heating field and glass industry. It is recommended for use in fire screens and partitions, as a fireproof lining for ceilings, walls, floors, elevator shafts, moving picture machine booths, ranges, stoves, grates, electric ovens, sterilizers and roasters.
Both No. 1 and No. 7 grades of Asbestos Miliboard meet Federal Specification HH-M-35U.
Sizes: Asbestos Millboard is furnished in 42" by 48" sheets in thicknesses from 1/32" to 3/4".
Packaging: Asbestos Millboard is packed in 100-lb. canons unless otherwise specified.
TABLE OF THICKNESSES AND WEIGHTS FOR NO. 7 GRADE*
r
i
Carey Asbestos Millboard is lighter in weight than other millboards...has higher insulation value per pound.
DESCRIPTION
Asbestos Millboard is made from pure Canadian asbestos fiber pulp which is mixed with binding materials and formed in sheets. Commercial Millboard is avail able in two grades. No. 7 Medium and No. 1 Hard. The No. 7 grade withstands temperatures up to 800 F., and the No. 1 grade withstands temperatures up to 1000 F. Though these two grades satis fy the vast majority of requirements, special grades can be developed by Carey laboratories.
Millboard with pin-point (knurled) finish can also be supplied.
ThicknessInches
1/32 3/64 1/16 5/64 3/32
1/8 5/32 3/16 1/4 5/16
3/8 1/2 5/8 3/4
Per Sheet Pounds **
2.0 2.8 3.85 4.8 5.82
6.93 9.0 10.35 14.01 17.5
20.28 26.53 34.3 39.8
.
* No. 1 grade weighs approximately 10% more than No. 7 grade, **Correct to + 10%.
Per Sq. Ft. Ounces
2.3 3.2 4.4 5.5 6.6
7.9 10.3 11.8 16.0 20.0
23.1 30.3 39.2 45.5
ASBESTOS SHEETS AND PANELS
industrial insulation
INDUSTRIAL A-C BOARD
This board is composed solely of Port land cement and asbestos fiber. It is fire-resistant and actually becomes stronger with age. Industrial A-C Board is unaffected by most acids and alkalies, heat and cold. It is rot-proof, verminproof, termite-proof, rodent-proof, and it does not corrode. Having a natural ce
ment gray color. Industrial A-C Board does not require protective coatings or paint, although it can be painted if de sired. This board withstands temperatures up to 800 F.
Industrial A-C Board is available in standard sheets 42** by 48", 48" by 48". 42" by 96". and 48" bv 96" in thick nesses of 1/4", 3/8" and 1/2".
THERMO-BORD
Thermo-Bord is composed of 1/8*' as* bestos-cement board bonded to both sides of a special asphalt-impregnated type insulation board. The bonding material is moisture resistant, forming a vapor barrier between the asbestos-cement board and insulation board.
Thermo-Bord is recommended for roof decks, outside walls, partitions, and low-temperature ovens (not over 200 F.).
Standard sheets are available 4* wide in lengths of'6*, 8*, 9*, 10* and 12*. Overall
thicknesses: 3/4", 1-1/8", 1-9/16** and
2".
4.2 CAREYSTONE CORRUGATED SHEET
ASPHALT PLYBOARD
Asphalt Plyboard is laminated from altemate layers of asphalt-saturated felt and a specially developed thermoplastic asphaltic material. It replaces wood, ply wood, hardboard, meta's, plastics, composition boards, fabricated krafts and allied products. This extremely pliable board is easily nailed, cut, stamped or punched.
Asphalt Plyboard is a versatile and in expensive construction material for basement ceilings, temporary flooring, farm storage bins and animal house", and auto trunk boards,
Asphalt Plyboard is manufactured in thicknesses from 1/16" to 3/8"; widths up to 60** and lengths up to 120*'. Facilities are available for special lengths up to 144".
Careystone Corrugated is made from Portland cement and asbestos fiber, compressed under enormous hydraulic pressure to form a homogeneous mono lithic sheet. Careystone Corrugated actually becomes stronger with age.
These sheets are excellent for roofing and siding on industrial and commercial
buildings. They are also widely used as a decorative building material.
Careystone Corrugated sheets have 10 corrugations in a 42-inch width. Sheets are available in standard lengths from 1* to 12' in multiples of 6". The aver age thickness is 3/8**. Average weight per sq. ft. bulk is 4 lbs.; weight per sq. ft. crated is 4-1/2 lbs.
Carey Industrial Insulation
'EFOIL BOARD
r.<efoil Board consists of successive plies of corrugated asbestos paper bond ed with a special fire^esistant adhesive, treated with a chemical and hardened to make a strong, fire-resistant, waterresistant board. It is easily sawed and drilled with ordinary hand tools.
Firefoil is recommended for interior use only, in such applications as bulkheads, air-conditioning housings, and oven en closures. Firefoil withstands tempera tures up to 1000 F.
Standard sheets are 4' by 8*, available in thicknesses from 1/2" to 1" in 1/8** multiples, and from 1" to 3" in 1/4** multiples. Approximate weight is 1 lb. .per sq. ft. per 1/2** of thickness.
Asbestos Sheets and Panels
SPUN MINERAL WOOL DUCT INSULATION
findustrial ^insulation
DESCRIPTION
Career Ooct Insulation is made in semi-rigid sheets, pro cessed from long fine fibers of spun mineral wool. Light in weight, with a density of approximately seven pounds per cubic foot, this insulation is easily handled and quickly installed. It provides a high degree of thermal efficiency as indicated by the accompanying table.
FEATURES
Moisture Resistant -- made of spun mineral wool fibers that will not absorb moisture, Carey Duct Insulation is non-capillary in character. If the surface accidentally be comes wet, it can be dried off rapidly without affecting its original properties and can be applied at once.
Non-Corrosive -- this insulation, inorganic in composition, does not cause corrosion of metal duct surfaces.
Workability -- Carey Duct Insulation is easy to cut with a knife to conform to irregular flat shapes. Far curved sur faces, it can be quickly scored for bending either way to match the contour of the doct.
Non-Irritating to Handle -- Carey Duct Insulation has a smooth, clean surface and is free from loose particles. It can be handled with bare bands without discomfort.
Finish -- Carey Duct Insulation may be brush or spraypainted, or coated with weatherproofing compounds.
Underwriters' Laboratories -- Both plain and coated Carey Duct Insulation have been tested and rated by Underwriters' Laboratories.
USES
Carey Duct Insulation, for air conditioning ducts and heat ing ducts, is available plain, with factory-applied vapor barrier, neoprene coating or foil-faced.
Carey Duct Insulation with vapor barrier -- Recommended for use in warm, humid areas where condensation is a
factor. Vapor barrier is applied at the factory and consists of 40 lb. black kraft paper coated with asphalt.
Carey Duct Insulation with neoprene coating -- This coat ing on one side with neoprene compound prevents fiber entrainment. Applied inside of ducts as a lining, it reduces fan noise and prevents its transmission by the moving air into areas served by the system. Where applied to the ex terior, the coated side facilitates painting.
Foil-Faced Duct Insulation -- This duct insulation is faced on one side with .001 aluminum foil laminated to SO-pound flame-resistant Kraft, 2x2 scrim and flame-resistant adhe sive. The maximum temperature limit is 250 F. Thermal Conductivity: "K" .24 at 75 F. mean temperature. Perme
ance to Water-Vapor: Less than .25 perms under ASTME-9653T Method "C".
SPECIFICATIONS
THERMAL CONDUCTIVITY (K Factors at Mean Temperature F.)
0
25
50
75
1" Thick .21 .22 .23 .24
. 25
100 .29
200
SOUND ABSORPTION COEFFICIENTS
(Frequencies)
125
250 500
1000
1" Thick .32 .58
.70
.93 .95
2000 .80
N
Thickness Pieces Square Ft.
PACKAGING
Plain or Coated In Cartons
Vapor Barrier In Paper-Wrapped Bundles
3/4" 1" !%' 2" 16 12 8 6 128 96 64 48
3/4" 1" ifc" 2" 8 64 3 64 48 32 24
Size: 24" x 48".
Density: Nominal 7 lb. per cu. ft.
Maximum Temperatures: Plain Carey Duct Insulation is suitable for insulating surfaces up to 450F. With the vapor barrier it is not normally used in hot areas and naturally should not be used at temperatures in excess of 150E. because the asphalt may soften.
ASBESTOS PAPER AND ROLLBOARD
Industrial insulation
from hard, rocky particles. This pure asbestos pulp is mixed with a small quantity of very strong binding material, formed into endless sheets of different weights, thoroughly dried, calendered to a smooth finish and put up in rolls ready for shipment. Asbestos Paper and Rollboard are strong, flexible, fire-resistant sheets.
SPECIFICATIONS
Asbestos Paper and Rollboard is fur nished in standard widths of 18", 24". 36" and 37-1-2" in rolls weighing ap proximately 25, 50 and 100 lbs. For manufacturing purposes, jumbo rolls of 200 to 400 lbs. are furnished. Special sizes can be made to order.
Asbestos Paper tape, made from standard 12-lb. stock, also is available in 2" and
3" widths.
USES
Asbestos Paper and Rollboard is fur nished in many weights to meet varying insulation requirement'.
DESCRIPTION
Asbestos Paper and Rollboard is com posed of pure Canadian asbestos fiber, which is slurried to a pulpy mass, free
Commercial Grade Asbestos Paper is entirely satisfactory for most purposes. The 6-pound and 8-pound papers are used extensively in the manufacture of various pipe insulation and electrical insulation.
The 10-pound and 12-pound papers are used for wrapping hot air furnace pipes. Heavier weights are used for lining stoves, ovens, gas ranges and for making gaskets, filters and discs.
Table of Weights and Thicknesses
Lbs/100 Sq Ft ( t 10%)
Approximate Thickness-~!n.
4 lb 6 lb 8 lb 10 lb 12 lb
14 lb 16 lb 1/16" (32 lb) 3/32" (48 lb) 1/8" (64 lb)
.010 .015 .019 .022 .027
.029 .032 .0625 .093 .125
Carey Rollboard used as a tank lining, Rollboard is strong, flexible, easy to install -- fits a variety of installations.
CORRUGATED ASBESTOS PAPER
Industrial | insulation i
DESCRIPTION
SPECIFICATIONS
Corrugated Asbestos Paper is made by bonding a sheet of corrugated asbestos paper to a sheet of flat asbestos paper. It is a very light and flexible insulation.
Sizes: Corrugated Asbestos Paper is furnished in coarse corrugations 1/4" thick per ply (Aircell), and in fine cor rugations 1/6" and 1/8" per ply. Rolls 36" to 37" wide are available in 250 sq. ft. and 500 sq. ft. sizes.
USES
Corrugated Asbestos Paper is recommend ed as a wrapping for curved surfaces, such as hoi air furnace pipes and hot air ducts in blower systems used in heating and ventilating large building.
Packaging: Aircell (1/4" deep corruga tions) Corrugated Asbestos Paper is packaged in cartons 18" by 18" by 38", weighing approximately 50 lbs. gross. A box car holds approximately 400 cartons.
Carload quantities of 500 sq. ft. rolls can be shipped in bulk. These rolls are protected by a wrapping of Kraft paper secured with gummed tape.
f \
V
REFERENCE DATA
y
&
v
foe*. m u ltip ly *4 l i Io m m in t* b U b y th u facioc T b Ic i w p tt *q I t o# p ip * iu i4 ( fo r p p n U rfftr i Km 2 4 ' can b * cofti4irad iH * M m * u t in la n w fo r th o 24* pip*
e = <
*-
y - - - '-- - ----- '
-
N
s *4 44 44 5 IS 44 is is is 5 - 44 IS y
S a a s 8 *4 = S s s a 3 s 2 44 8 3 a
-N
*4
*s
s
44 44
is
44
44
s
s
P4
s
~
s
s
s
-
-
8S
2 3 a fON- 3 8 S 8 3 3 44 9 3 2 3 9
= *4 = s s 8 8 8 8 8 8 44 8 44 8 8 8 8 8
S 3 8 8 s 3 *4 a s 3 8 2 s 4444 8 2 2 8 3
8 >
8
3 S a ; 2 a *4 8 2 O 8 3 Q 3 3 3 9
C 2 2 40 2 2
S
- 3 ; Ss a s s Px 2 = O O 8 8 8 m 2
*. *v Px
is
8
3 J*
a85-2S 3a 9---
* sO
- 0
4U>
l* 3 75
<
E1
-T3
C
1
a1
03
a|
&
"5 2 9
75 ie wu >2 <9 u. X&
j
1
2
ot
X 5 i2
u0 u*
i
t/5 o
9
s a g u. 9 s <j
c
a aJ
g
e a
s
a
?
8 u.
e a
O i i
a
s
a
s $ s 2 C4 8 3 hx 3 3 9 3 8 C 2 -- 3
S'
4X yx
2 a 5 * 2 8 3 a 8 8
- 3 5 3 s x 8 IH = 8 s a 3 9 S 8 * 2
s *3 ~
3$ * ^4 IS
- 44 - * - 8 8 O 8 3 8
is is 44 44 44 44
* a -- = i a J 2 S 2 a IS 44 I4S4 2 - 8 -
s 3 3 8 s -- 3 3 ; 2 8
e
ft
O
s 2 2 o o 3 s 8 3 8 a 2 Is 3 3 3 4X 3 o
8
;
a
a
is
44
8
4| 9
a
8
3
3
8
2
O' o>
4* 2 3 lx. 3 * m 44 a 8 4y
----3
<
a
> PS
Ps
4 4*
44
$
PS
3
a
=
5a 3 3 #*
3
x
P4
44
44
=
0
8
3
3
'* 4H (X, - ~ *- * * ~ * -
* *
2
o
g
3
8
3
8
2
IS
S
3
S
2
IS
3
2;3a
'* **
$;
2 3* 4 IS 8 2
O s8333a832
* 4 -> -
* h 2 Px 3 a a = 3 3 5 - a 3
* yx y x *
" 14 44 8 = 8 8 3 3 3 a
s -
$
3
3
3
*4
a
-
3
23
9
2
8
x
4
-
*
-
-
9
-
0
3 2
3
a
2
8 -- 3
a-
O 2
3
2
8
8 2
8
(9
i)
| =a="8
2 8 Py s 3 8 3 =
= 8
=
3
X
o 8332 % 3 3 aa
a332-am3
S
a 8 a ~ 8
?? 8 i
<
3 9 2 2 4 a 5 = = 2 - 44 = 8 3 a
** S a 8
- a 8 Px 2 2
8
* -- -* "
~ A y *>4 * 4| * 14
~-
m3
a
g
"
2 #4
2
IS
P4 "*
44
3
IS
4g
s
44
44
5 IS
2 4
44
-
*
s s 3 a ^4 * 3 2 44 3 2 a 4*
**
*4 *4 ** 14
14 **
44 iy 44 * 44 **
-*
a 5 a2:
8 -288Oe8932
*9 A*
*4 ** " *4
44 ** 4
"* 44
44 4| - - - -
s 8 3
a
8
rs
5
3
g
2
44
8
3
3
3
**
**
3 -
a
=
5* 3
-
___
28
t
ys
o>
*AN
2
3
tt
1
2
i
8
9
3
8
2
a
-- -- . -- -- -- 4 44 44
# *
"*
" *8
1 8*1
>S * i* 2* - y* sp
~ " *
IS
* **
1
s
8
-
M i H-sf zJiZs
5
i
E
S
i 803 7 1 t t
J
8
3
'T o h <# lo im p*<
f
.I B
\
r n
( C'
HEAT INSULATION
FOR
HIGH TEMPERATURES Thermal Tables
BULLETIN 101 BX
BETTER PRODUCTS FOR INDUSTRY SINCE 1873
THE PHILIP CAREY MFG. COMPANY
Gtmral Office -- LOCKLAND. CINCINNATI OHIO Branches la All Principal Cities
)'
I
Even 48 hours
of "soaking heat"
at 1600 F...
cause undue shrinkage or cracking
of new CAREY ALLTEMP insulation!
ALLTEMP is a special combination of inorganic silicas and asbestos fibers, with physical and chemical properties giving excellent ef ficiency in heat saving and very low shrinkage (up to H less than many 1200* F * 1500 F insulations). It is non-brittle, easily workable and keeps its high thermal efficiency and strength, even through continuous exposure to excessive heat and moisture.
ALLTEMP is made in sectional, tri-sectional and segmental blocks. In "nesting" pipe covering sizes, a wide range of unusual assemblies can be built-up from a limited number of "prime" units, with application in either single or broken joint double layer construction. Use it for temperatures from 100 to 1600 F for top efficiency in keeping heat on the job.
Other famous insulation products developed by Carey include Super Light 85% Magnesia, Hi Temp No. 19, Tempchek, MW-50 and Mw-One Insulating Cement ana a complete line of bonding and fin ishing cements. There is a Carey-approved contract unit conven iently located to work with you in selecting the insulation most suitable for your needs, and assure its use to best advantage. Con sult your telephone directory, or your nearest Carey district office. The Philip Carey Mfg. Company, Lockland, Cincinnati 15, Ohio.
Plants: Cincinnati and Middletown, Ohio; Wilmington, II!.; Memphis, Tenni; Perth Amboy, N. J.: Houston. Texas: Plymouth Meeting, Pa.: lennoxviile, P. Q.; East Broughton, ?. Q.; Research Center, Cincinnati, Ohio. Subsidiary Companies: General Magnesite 4 Magnesia Co.; Quebec Asbestos Corporation, ltd.; The Philip Carey Company, ltd. 'he Lehon Company.
can count on
divarsifiad product* and sarvkas for industry, farm and homo smco 1873
Pipe Size In.
% y* i VA V/2
2
3
4
5
6
COMBINATION COVERING FOR 600 F.
* Indicates Recommended Combinations
INNER LAYER CAREY AUTEMP, OUTER LAYER SUPER-LIGHT <5% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
2 Hs l 2H
2% *1%
1*% 1*56
l1^ *1%
1% 1% 1% *1% m m
i%
VJ6 M
W m 1H
Outer Layer Thickness Inches
None None None None None
1% VJ4 2% 2% 3*6 1M 234 2% 3%
1% 2% 2% 3H 1% 2J4 2% 3H l1^ 2% 2**6
3H
Temp. F. at Inner Magnesia Surface
298 329 357 380 393 343 376 394 409 356 382 403 421 368 396 422 470 378 399 429 443
Canvas Temp. F. with Air at 80 F.
115 118 118 124 118 116 108 102 100 98 111 106 103 101 112 107 103 100 115 109 104 98 116 108 105 102
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
79 626
91 772
98 950
115 1,190 111 1,350
111 1,670
102 1,670
88 1,670
84 1,670
80 1,670
105 2,420
112 2,420
104 2,420
97 2,420
146 3,070
132 3,070
120 3,070
109 3,070
168 3,750
150 3,750
131 3,750
97 3,750
190 4,440
152 4,440
149 4,440
137 4,440
Percent Eff. %
87.3 88.2 89.6 90.3 92.0 93.3 93.8 94.7 95.0 95.2 95.6 95.4 95.7 96.0 95.2 95.7 96.0 96.4 95.5 96.0 96.5 97.4 95.7 96.5 96.6 96.9
P*ge 3
Pipe Size In.
8
10 r
12
14
16
18
Flat
COMBINATION COVERING FOR 600 F.
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
* l1^ 1%
i1^
il% v%. *m v% V%
1%
MH IA lH
- iy2
1H Wo IA *W2 w w m * W2 IA m lH
Outer Layer Thickness Inches
256 25A
356
IA
2
2A
3
IA 2 2A
3
IA 2 2A
3
1A 2
2A 3
1A 2 2A 3 IA 2
2A 3
Temp. F. at Inner Magnesia Surface
376 412 431 444 380 408 430 446 386 410 428 450 402 424 446 460 403 426 448 462 404 429 451 464 414 445 466 481
Canvas Temp. F. with Air at 80 F.
118 111 107 104 120 114 109 105 120 115 110 107 122 117 112 108 124 118 113 109 125 119 114 109 123 117 113 109
B. T. U. Loss Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
230 5,710
196 5,710
176 5,710
164 5.710
270 7,040
239 7,040
213 7,040
191 7,040
304 8,320
274 8,32C
247 8,320
223 8,320
340 9,050
307 9,050
271 9,050
245 9,050
390 10,300
344 10,300
302 10.300
268 10,300
438 11,560
373 11,560
330 11,560
283 11,560
73.1 2,590
62.2 2,590
54.2 2,590
48.0 2,590
Percent Eff. %
95.9 96.5 96.9 97.1 96.1 96.6 96.9 97.2 96.3 96.7 97.0 97.3 96.2 96.6 97.0 97.3 96.2 96.7 97.0 97.4 96.2 96.8 97.1 97.5 97.2 97.6 97.9 98.1
Peg* 4
1 ! p*p
Size In.
Vi % 1 VA VA
2
3
COMBINATION COVERING FOR 700 F
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
2*5 1*% m m 2*e
v%. v%. ij%
*1%
i% 1% *i%
i%
*i%
i>%
*1H lM 1H 1H
Outer Layer Thickness Inches
None None None None None 1% 1*% 2%
2% 3*6
2% 2i% 3%
11% 2% 21% 3% 11% 2%
2i% 3M 11% 2% 21*6 3H
Temp. F. at Inner Magnesia Surface
345 383 415 442 457 400 436 459 475 415 447 470 490 429 461 492 540 440 473 500 515
Canvas Temp. F. with Air at 80 F.
122 126 126 132 126 123 114 108 105 101 118 112 108 104 119 113 109 104 122 115 109 102 124 115 111 107
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
102 878
117 1.080
126 1,340
149 1,680
143 1,900
141 2,350 127 2,350
113 2350
110 2350
99 2,350
144 3,400
141 3,400
131 3,400
122 3,400
184 4320
165 4,320
150 4,320
137 4,320
211 5,300
189 5,300
164 5300
125 5,300
239 6370
199 6370
186 6370
172 6370
Percent Eff. %
88.4 89.2 90.6 91.1 92.5 94.0 94.6 953 95.3 95.3 95.7 95.8 96.1 96.4 95.7 96.1 96.5 96.8 96.0 96.4 96.9 97.6 963 96.8 97.0 973
P*e 5
Pipe Size In.
Yz % 1 VA VA
2
COMBINATION COVERING FOR 800 F,
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 P. Ambient Air Temperature
inner Layer Thickness Inches
2*6 13& 2H me 2*6 v% 1*56 1%
1*6 1*6 1*6 1*6
*1*6 1*6 1*6 1*6 1%
*1%
m VA
VA VA
Outer Layer Thickness Inches
None None None None None
1% 1% 2*! 2*6 3*6
VA
2*f 2% 3% 1% 2^ 2% 3H 1% 2^ 2**6
1% 1% 2%
2**6 3H
Temp. F. at Inner Magnesia Surface
391 438 473 505 522 458 497 524 542 474 511 537 560 489 526 562 435 502 547 572 588
Canvas Temp. #F, with Air at 80 F.
129 134 133 141 133 130 121 114 110 105 125 117 113 108 126 119 114 109 129 122 114 124 131 123 117 113
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
125 1,180
143 1,460
154 1,820
182 2,270
176 2,580
171 3,200
154 3,200
139 3,200
136 3,200
119 3,200
183 4,640
171 4,640
157 4,640
147 4,640
222 5,920
198 5,920
180 5,920
165 5,920
254 7,260
228 7,260
198 7.260
234 7,260
289 8,600
246 8,600
223 8,600
208 8,600
Percent Eff. %
89.4 90.2 91.5 92.0 93.2 94.6 95.2 95.6 95.7 96.3 96.0 96.3 96.6 96.8 96.2 96.6 96.9 97.2 96.5 96.8 97.2 96.7 96.6 97.1 97.4 97.5
PERFORMANCE DATA:
HEAT INSULATION
F0R
TEMPERATURES TO 600'F.
BULLETIN No.104-A
THE PHILIP CAREY MFG. COMPANY
GENERAL OFFICES: IOCKIANO. CINCINNATI IS. OHIO
2-4 INS T04-A-900
FOREWORD
85% Magnesia, with an enviable performance record of over seventy years, stands alone today as the accepted standard of thermal insulation. Men charged with the responsibility of designing and operating the many types of equipment that make up our modern industrial processes specify 85% Magnesia.
It is paramount to select a proven thermal insulation having the greatest re sistance to the flow of heat--thus obtaining the maximum in economv. Mechan ical properties adaptable to the particular problem must likewise be considered in balancing of savings against cost of insulation.
Super-Light 85% Magnesia combines thermal and mechanical characteristics, is a superior product compared to the old style filter molded 85% Magnesia, and has light weight, high strength, low conductivity, great resistance to moisture, smooth finish, accurate fit. shock resistance and high dimensional stability--it will not crack due to internal shrinkage when applied on hot surfaces up to 600 'F. It effectively resists handling, shipping, impact and traffic; will not disintegrate, crack or crumble under normal service conditions, and may be removed for in spection of equipment and reapplied when necessary. It has excellent workability and high ductility. Carey Super-Light 85% Magnesia can be subjected to boiling water for hours without disintegration--a quality derived from its chemical "set*' monolithic structure.
To assist in engineering calculations of problems in heat balance the data in this bulletin have been assembled. They will save much time. They reflect the care and accuracy of a specialized heat research laboratory, both as to performance of insulating materials and rates of loss from bare surfaces. Conductivity values used are averages from tests made at the Mellon Institute on numerous samples. The values for heat losses from uninsulated surfaces are those developed bv R. H. Heilman, Senior Fellow of The Mellon Institute, based upon his experimental work in this field as published in the paper "Surface Heat Transmission," Trans. Am. Soc. Mech. Engrs. Fuel Steam Power, 51, 275, (1929). Since this work repre sents the most exhaustive research in this field, the data developed are probably the most reliable and give a satisfactory basis for evaluating heat-insulation savings.
Since Super-Light 85% Magnesia is so generally accepted a standard, a com plete set of thermal tables is given for this product. A set of BASE THERMAL TABLES to be used in combination with factors is given for other types of insu lating materials, making possible the development of similar data for such ma terials.
The Philip Carey Mfg. Company offers the services of its engineering organiza tion and laboratories for assistance in individual engineering problems.
2.4 (NS 104-A.90)
DESCRIPTIONS OF CAREY HEAT INSULATIONS
CAREY 85% MAGNESIA
For tempera lures up to 600 e F. Fur nished in semi-cylindrical pipe cov ering sections for pipe sizes up to 18 inch and in curved blocks for larger pipe sizes, also in flat blocks. A molded composition of Carbonate of Magnesia and Asbestos Fiber. In combustible, non-corrosive: crushing strength 60 lbs. per square incb: unaffected by water. Combines high efficiency with a very durable structure. Long-lasting--its insulating value improves with age. Structure is rigid but not brittle. Can be easily worked with ordinary carpenters' tools. Easily cut and formed to accom modate irregularities. The accepted quality standard for low, medium and high-pressure steam service where maximum per manent efficiency is desired.
y CAREY AllTEMP
Produced from a formulation of ex
*-
panded silica* and asbestos liber.
Available in sectional, tri-sectional.
.`
.. ^
segmental and block forms. Alltemp ^ is recommended for insulating high
*
tempera lure piping and surfaces Mich
as breaching, boiler walls, ovens,
stills, and similar surfaces. It is an ideal insulator for irregular
surfaces, due to its workability and ease of application. Its ex
ceptionally low shrinkage factor, plus low co-efficient of con
ductivity, assures outstanding, economical performance when
used as a single material or in combination with Carey Super
Light 85' c magnesia. Alltemp is water resistant, and offers an
excellent surface for cements. Now accepted and being used by
principal boiler manufacturers, engineering contractors, and
industrv.
ASBESTOS- SPONGE
For temperatures up to TOO0 F. Fur nished in split cylindrical pipe cov ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. A resilient structure comprising ap proximately 30 to 40 layers of Asbestos Paper per incb of thick ness. The asbestos paper is processed with very small indenta tions, giving the finished product a spongy consistency, having very high insulating value. Asbestos-Sponge is specifically recommended for use on vibrating lines and for underground steam distribution lines because of its tough structure and because cylindrical pipe covering sections can be furnished for large pipe sizes.
.....v-HT* CAREY OEFENDEX
. ^ *'2;' ^
For temperatures up to 550 F. Fur
r ^ L -3; lis? nished in semi-cylindrical pipe cov-
J ."7* ering sections for pipe sizes up to
36 in., also in flat blocks and sheets.
*' . : / - T .- A semi-rigid structure comprising
- ' - * ,'*'* 7 approximately 20 to 22 alternating
~ layers of flat and processed asbestos
paper per inch of thickness. The processed asbestos paper
contains innumerable very fine indentations which give proper
spacing between succeeding layers. Defendex combines high
efficiency, medium price and tough laminated asbestos struc
ture. Recommended for low, medium and high-pressure steam
service.
MINERAL WOOL BLANKETS
For temperatures up to 1200 0 F. Fur nished in flexible blankets 1 in. to 6 in. thick, 2 ft. wide bv 4 ft. or 8 ft. long consisting of mineral wool fibers felted to desired thickness and reinforced with wire mesh or metal lathe on both sides. These blankets combine the properties of high temperature resistance, high efficiency, low cost, flexibility and large-unit construction mini mizing cracks and joints. Recommended primarily for use in enclosed walls of ovens and similar equipment.
CAREY A I R C E L L
For temperatures up to 300 F. Fur nished in semi-cyiindricai pipe cov ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. A firm structure comprising alter nate layers of corrugated and flat asbestos paper firmly cemented to gether. Corrugations are H in. deep--4 plies per inch of thick ness. The lowest cost, incombustible asbestos insulation. Recom mended only for moderate temperature pipes and equipment where high efficiency and durability are not important.
CAREY EXCEL
For temperatures up to 300 F. Fur nished in semi-cylindrical pipe cov ering sections for pipe sizes up to 36 in., also in flat blocks and sheets. A firm structure comprising alter nate layers of corrugated and flat asbestos paper firmly cemented to gether. Corrugations are 1, 6 in. deep--6 plies per inch of thick ness. Gives good efficiency and has more resistance to abuse and better appearance than Air Cell. Recommended for healing system piping and equipment.
CAREY THERMOGLAS
Thermoglas pipe covering is used on pipes having temperatures up to 350 F. It simply "snaps in place." Thermoglas is exceptionally light weight insulation and is composed of long, fine, blown glass fibers bonded with thermal-setting phenolic resin. It is a strong, semi-rigid and resilient insulation, with no coarse fibers to irritate hands or skin. Thermoglas is an excellent cold, dual-temperature insulation when used with a vapor barrier jacket. Vapor barrier for dual temperatures is furnished in black and white. Other types of jacketing are Foil Faced Flame Proof Kraft jacket or weatherproof jacketing at 35. 45, or 55 lb. weights. Also available with standard weight 4-oz., 6-oz. and 8-oz. canvas jackets.
DESCRIPTIONS OF CAREY HEAT INSULATIONS
* >.
CAREY CAREYCEL For temperatures up to 300* F. Fur
nished in semi-cylindrical pipe cov
ing sections for pipe sizes up to
T^.
16 in., also in Hat blocks and sheets. A firm structure comprising 12 to
^*~- - 14 layers of asbestos paper per inch
thickness. The asbestos paper is
processed with innumerable small indentations which space the
lavers, prevent internal convection, reduce conduction by contact
and create high efficiency. Incombustible, non-corrosive, rugged,
low heat shrinkage and inexpensive. Its unusually low heal
shrinkage makes it particularly desirable--minimizing unsightly
cracks and conserving high efficiency. Recommended for beating
systems and low' pressure process piping and equipment.
No. 303 ASBESTOS CEMENT
A general utility insulating cement. Furnished in 100-lb. bags. Com posed of a dry mixture of asbestos fibers and bonding clays. To use, it is mixed with water to a mortar consistency for application with a trowel. It adheres well to iron sur faces or to insulating materials, and trowels to a smooth finish. Covering capacity is approximated 18 sqi ft. 1 in. thick per 100 lbs. of dry cement. Recommended for pointing up joints in block insulation, for insulating small fittings in low-pressure systems and primarily for a smooth-fmisb coal over block insulation.
CAREY PERFECTO
For cold-water pipes to 53 s F. Fur nished only in semi-cylindrical pipe covering sections for pipe sizes up to 36 in. Not furnished in blocks or sheets. A semi-rigid structure com prising layers of indented organic insulating felt (sometimes termed ''wool fell*') firmly cemented together. Inner surface is lined with asphalt-saturated felt. Gives very high insulating value. Gives good results in preventing sweating and protecting from freezing. Recommended for service water piping carrying water down to 55* F.
No. 707 ASBESTOS CEMENT
For temperatures up to 500 F. Fur nished in 100-lb. bags. Composed of a dry mixture of asbestos fibers and bonding clays. To use. it is mixed with water to a mortar consistency for application with a trowel. It adheres well to iron or insulation surfaces, and trowels to a semi-smooth finish. Covering capacity is approximately 25 sq. ft. 1 in. thick per 100 lbs. of dry cement. Recommended for pointing up joints in block insulation, for insulating small fittings and for a finish coat over block insula tion where high efficiency rather than smooth finish is desired.
CAREY IMPERVO
For cold and ice water piping to 35 F. Furnished only in 3-foot long
CAREY MW-50 CEMENT
cylindrical pipe covering section*.,
For temperatures up to 1600* F.
for pipe sizes up to 36'. Not fur
Furnished in 50-lb. bags. Composed
nished in block- or sheets. A semi
of a dry mixture of springy pellets
rigid structure comprising layers of
of mineral wool, asbestos fiber and
<
insulating felt cemented together
bonding clay. To use, it is mixed
with asphalt saturated organic felts applied to both inner and
with water and applied with a
outer surfaces. Telescopic double layer construction recom
trowel. Covering capacity is ap
mended to provide staggered joint insulation and prevent air
proximately 50 sq. ft. 1 in. thick per 100 lbs. of dry cement.
infiltration. Gives verv high insulating value. Use for insulating
Combines high insulating efficiency, toughness, reasonable hard
chilled and ice water lines to keep water cold and prevent
ness, excellent sticking properties and relative freedom from
sweating. Proper sealing by use of a suitable vapor barrier is
shrinkage cracks. Recommended as monolithic insulation for
recommended to prevent infiltration of water vapor through the
stills, tanks, furnace walls, etc. particularly where temperatures
harrier into the insulation, causing condensation.
of 600* F. or higher are encountered.
CAREY PROTECTO
Reduces the danger of freezing of
exposed piping. Furnished only in
3-ft. long semi-cvlindrica) pipe cover
ing sections, for pipe sizes up to 36'.
Not furnished in blocks or sheets. A
semi-rigid structure, consisting of an
inner portion of cattle hair felt and
an outer, reinforced structure of insulating felt (sometimes
termed ''wool felt"). Furnished in
and 2" thicknesses.
Inner surfaces are lined with asphalt-saturated felt. Gives very
high insulating value and i& especially designed for reducing
danger of and delaying freezing time for unprotected water
pipes. No insulation alone can prevent freezing, if the water
stands still long enough. During extreme low temperature con-
dilions, some water must be allowed to run during weekend or
idle periods.
CAREY MW-ONE CEMENT
A one-coat, white finishing. Fur nished in 50-lb. bags. Composed of mineral wool pellets and other in* gredients. giving an all-purpose, fast setting, finishing cement that in sulates as well as protects. One-coat application, in the required thick ness, saves time, labor and money. Hydraulic setting takes place in two hours. MW'-One may be used directly over insula tion and as a finishing cement for MW-50. Covering capacity for MW-One cement is approximately 35 sq. ft., 1* thick, for 100 lbs. Can be furnished for temperatures up to 1800 F. (grey finish) and for use over non-ferrous materials in lots of 100 bags minimum.
HEAT INSULATION FACTORS
A complete set of performance tables for Super-Light 85 'c Magnesia Hill be found oo pages 905 to 909 inclusive.
Performance values for other Carey beat insulation materials can be obtained by using the following table of factors which gi%e beat transmission relationships. These factors provide a quick and simple method of obtaining insulating values without the use of voluminous tables for each insulating material, and the per cent of error involved by their use is very small--generally less than the variation in heat transmission between different samples of the same material. The beat losses and efficiencies of the variou> Carev insulations can be determined by the use of these factors applied to the BASE THERMAL TABLES given on Pages 910 to 914 inclusive of this bulletin.
TEMPERATURE DIFFERENCE, DEGREES FAHRENHEIT BETWEEN HEATED SURFACE AND AIR
TYPE OF INSULATION
Aircell..................................................................... Asbestos Sponge................................................. Carevcel............................................ .................... Carocel........... ....................................................... Defendex............................................................... Excel....................................................................... AlUemp................................................................. Thermoglas ......................................................... Hi-Temp No. 19............................................... Impervo ............................................................ Mineral Wool Blanket...................................... Perfecto................................................................. Protecto. ............................................................... 303 Asbestos Cement........................................ 707 Asbestos Cement...................................... MW-50 Cement.................................................. MW-One Cement. . -......................................
100
1.400 1.050 1.090 1.400 1.143 1.360 1.228 .7^2 1.475 0.936 0.718 0.919 0.840 3.72 2.362 1.547 1.622
200
1.444 1.048 1.110 1.410 1.171 1.376 1.205 .712 1.408 0.949 0.746 0.907 0.812 3.49 2.295 1.499 1.552
300 1.488 1.045 1.130 1.420 1.199 1.392 1.182 .702 1.340
0.773
3.26 O *><>g 1.451 1.482
400 1.043
1 22? 1.159 .692 1.273 0.801
2.161 1.403 1.412
500 1.040
1.255 1.136 1.205 0.828
2.004 1.355 1.342
600
1.113 1.138 0.856
2.027 1.307 1.272
To find UNIT HEAT LOSS fB. T. L". per square fool per ;F. temperature difference between iron and air per hour1 multiplv the unit loss for corresponding conditions in the BASE THERMAL TABLES bv the heat insulation factor of the insulatinn for which this information is wanted.
Example: What is the unit heat loss (B. T. U. per square foot per 0 F. temperature difference between iron and surrounding air per hour) for Carocel Covering 1' thick, for 3' pipe at 200 F. temperature difference between pipe and the surrounding air (steam in pipe at 270 F. and air temperature of room 70 F.)?
Heat insulation factor for Carocel at 200 F. temperature difference from table U 1.410.
Unit heat loss from BASE THERMAL TABLES for 1 * thickness for 3' pipe at 200 F. temperature difference between pipe and surrounding air is 0.419 from table on page 910.
0.419 x 1.410 -- 0.590 B. T. U. per square foot per degree F. temperature difference between pipe and air per hour.
To find the EFFICIENCY of a Carey insulation listed in the table of factors, first find from BASE THER MAL TABLES the efficiency of the corresponding Covering for the conditions in volved--subtract this from 100--multiply the difference by the beat insulation factor--subtract this product from 100.
Example*. What is the efficiency of Carey Carocel Covering 1' thick for 3' pipe at 200 F. temperature difference between pipe and the surrounding air?
Heat insulation factor for Carocel at 200 F. temperature difference from table is 1.410. Efficiency of 1' thick
Ol X 4*
II
BAS ETHER M A L TABLE Covering for same conditions is 84.9r7 from page 9J0. 100--84.9 = 15.1.
* 21.29. 100--21.29 == 78.71fc efficiency desired.
To find the SAVINGS in B. T. U. per lineal fool per hour for a Carey insulation shown in the table, first determine its effi ciency as indicated above, multiply this efficiency by the cor responding saving for BASE THERMAL TABLE Covering under the same conditions of pipe size, temperature and thick ness, and divide by the efficiency of BASE THERMAL TABLE Covering for these same conditions.
Example: What are the savings in B. T. U. per lineal loot of pipe per hour for Carey Carocel Covering 1 * thick for 3' pipe at 200 F. temperature difference between pipe and surrounding air?
Heat insulation factor for Carocel at 200 F. from table is 1-410.
Tbe efficiency of Carocel under these conditions is 78.71 Cc (see previous example).
Efficiency of BASE THERMAL TABLE Covering under these conditions is 84.9^ from the table on page 910.
Savings by BASE THERMAL TABLE Covering under same conditions are 431 B. T. U. per lineal foot per hour from table on page 910.
T8 ~1
431 x ^ ^ -- 398 B. T. L". per lineal foot per hour,
savings required.
HEAT INSULATION DATA
CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 1 lA" Thick
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES
Savings of* in B. T. U. p*f lin*or foot of pip* p*f hour. Unit hint or* m B. T. U. par squor* foot of pip* surface p*r hour p*r "F. temperature
difference between pipe ond surrounding oir.
Pipe Size
TEMPERATURE DIFFERENCE *F. KTWEB4 PIPE ANO SURROUNDING AIR
ISO 350
400
: 1 Efficiency------
}/* ' ! Savings ...............
j Unit Lots.............
3/g
7'
; 1 Efficiency......... | Savings ................. i Unit Lou ..........
j 'Efficiency.........
i Savings
.
| Unit Loss...............
iy*"
'Efficiency......... Savings .................
Unit Loss .............
Vh"
1 Efficiency......... Savings....................
Unit Loss ... .
i"
1, Efficiency.. . Savings ..............
Unit Lots ... .
,, ! 1; Effiey.........
2/2
Savings ...............
j Unit Loes .............
' i Efficiency......... 3" Savings..................
Unit Lots...............
3V2"
1 Efficiency......... Savings .................
Unit Lou...............
4"
', Efficiency... Savings ................. Unit Loss . .
4/2"
Efficiency......... Savings ............ Unit Loss . . .
` i Efficiency .... 5" Savings....................
Unit Loss .............
1 Efficiency......... 6" Savings ...............
Unit Loss ... .
7"
1 Efficiency... Savings.................... Unit Lou...............
` Efficiency......... 8" Savings....................
Unit Lou...............
1 Efficiency.......... 9" Savings....................
Unit Lou................
10"
'Efficiency......... Savings .................
Unit Lou................
12"
1 Efficiency......... Savings .................. Unit Lou................
14"
1 Efficiency..........
Savings.................... Unit Lou................
16"
1 Efficiency.........
Savings.................... Unit Lou................
1 O" 1O
! 1' ERwieacy.........
Savings.................... | Unit Loes................
Flat
1 Efficiency..........
79 6i 43
.505
50 si S4
466
83 If; 68
403
84 61 86
.360
84 61 97
. 355
85 91 121 320
85 11 143 333
87 O'-, 175 286
85 61 195 314
87 61 223 268
86 01 241 299
87 91 272 258
87 91 320 .253
88 31 366 .243
88 41 411
.238
88 51 456 .235
89 01 508
.224
88.91 596 .222
88.61 648 .227
88.71 735
.224
88.81 821 .222
90.41 194
.205
81.41
75 521
82.71
113 .537
S3 81
157 553
84 81 1 85.61
209 1
268
.569 1 .585 j
86 61 340 .600 i
87 31 420 616
88 01 511 632
88 8' 6IS 648
82 41
93 481
83 71 140 495
84.81 196
.510
85 71 i 86.SI i 87.41
260 1 333
423
.525 1 .540 |
.554
88 11 S22 ; 569
88 81
89 4".
636 1
764
584 598
84 51
117 .416
85 61 176 429
86 61 245
.442
87 41 326 455
88 11 ; 88 91 1 89.61 j 90 2',
418 |
530 1
654 !
797 ;
468
480 I
493 |
506 :
90 7', 957
S19
85 81 147
371
87.01 222
382
87.81 309 .394
88 61 411 405
89 31 527 .416
90 01
668 427
90 61 j 91 11 j 91 61
825
1005
1208
438 j
450 |
46)
86 01 167 366
87 01
251 377
87.91 350 .389
88 61 465
400
89 31 596 411
90 01 757
422
90 61
91 21
936 ; 1140
433 I
445
91 V .
1371
4S6
87 11 208 330
88 n 312
340
88 91 426 .350
89 61 579 360
90 21
743 371
90 9'; 943 381
91 41 j 91 91
1166
1421
391 .401
92 4' , 1709 411
86 41 246 344
87 41 370 354
88.31 516
365
89 01 687
.376
89.61 . 883 .387
90 41
1123 .397
90 9'; 1389 408
91 5', 1695 419
92 0' . 2041 429
88 n 301 295
89 01 452
304
89 81 630 314
90.41 838 323
91 01 1077
.332
91.61 1369
.341
92 21 1694
3S0
92 6', 2066 360
93 O' , 2487
369
86 81 336 324
87 81 504
335
88.61 70S
345
89 41 939 .356
90.01 1207
366
90 71 1537
376
91 31 1904
.387
91 8'. 2325
397
92 31 2802
408
88 61 382 277
89.51 574
285
90 21 801 294
90.81 1065
302
91 41 1370
311
92 11 1744
319
92.51 2159
328
93 01 2636
336
93 41
3175 34S
87 21 415 309
88 21 624
319
89 01 872
329
9 71
1162 .339
90 31 1405
.349
91 01 1905 358
91 61 2362 368
92 11
2885 378
92 6',
34 79 386
88 91 467
266
89 71 701 275
90 51 979 283
91 11 1303 292
91 6<; 1677
300
92 21 2135
308
92 71 2644
.317
93 21 3230
32S
93 6' ,
3893 334
89 01 549 261
89 81 82S
270
90 $1 1154
278
91 21 1537
286
91 71 1978
29S
92.31 2S20
.303
92 81 3125
311
93 21 3818
319
93 6' , 4604
.328
89 31 . 628
251
90 11 94$
259
90 81 1 91 41
1320 I
1760
267 275
92 01 2266
283
92 61 2887
291
93 01 3S81 .299
>3 S'; 4377 307
93 9', 5289 315
89 41 706 246
90 21 j 90 91
1061 1
1484
91.51 1979
254 |
262 1
.270
92.11 2548 .278
92.71 3250 .285
93 if; 4032
.293
93 6', <930 .301
93 9' ; 594 7
309
89 51 782
. 243
90 31 1177
.250
91 01 | 91 61
1647 1 2196
2S8 i
266
92 11 2829 .274
92 51
3599 .281
93.21 4476
.289
93 61 5478
.297
94 01 6614 .304
89 91 [ 90 71
872 1311
.231
.239
91 41 | 92.01
1834 |
2446
246 1
.253
89 91 1022
.229
90 71 ! 91 41
1538 |
2154
.237 1
.244
91 9% 2874
.252
92 51 31S2 .261
92.51 3706 .259
93 01 4021 .268
93.01 4731 .266
93.51 4993 .275
93 51 5875 .274
93 91 6108 .282
94 31 7372 .290
93 91 | 94 21
7192
8684
.281
289
89 61 1112 .235
90 41 1674 .242
91 11 2346
250
91.71 3132
.257
92.21 4039 .265
92.81 5159 .273
93.31 6412
.280
93 71 7850
288
94 11 9486
.295
89.61 1261
232
90.51 1899
239
91.11 2661
.247
91.81
3556 .254
92.31 4588 .262
92.91 5863 .269
93.31 7289 .277
93 8 1
8931 .284
94 r;
10792 . 292
89 71 1410
229
90 SI 2124
.237
91.21
2979 .244
91.81 3981
.252
92 31 5136
. 2S9
92 91 6570
.266
93 41 8)70 .274
93 81 10014
.281
94 2': 12105
289
91 21 332
.212
91 91 497
.219
92.51 692 .226
92.91 920
.233
93 41 1181
240
93.81 1501
.246
94 2 1 1857
253
94 61 ! 2265
1 .260
94 91
2726 267
All data from Motion Inttitute, Univonity oi Pittsburgh tests.
HEAT INSULATION FACTORS
To find CANVAS TEMPERATL RES lor any insulation, inuliiplv the unit loss for corresponding conditions in the Base Thermal Tables by the heat insulation factor of the insulation for which the canvas temperature is wanted. Then find the outer diameter of the insulation by adding twice the thickness of the insulation to the pipe diameter. Multiply the new unit loss by the temperature difference between the pipe anil the air. and by the ratio of the inner to the outer diameter of the covering to obtain the BTL loss per sq. ft. of canvas. From Figure "Surface Losses for Various Outside Diameters" find the temperature difference between the canvas surface and the air corresponding to the BTL' loss per sq. ft. of canvas and the Outside diameter of the covering. Add 80c F to this value to obtain the canvas temperatures for 80 F surrounding air.
Example: What is the canvas temperature for Asbestos Sponge Covering 2 ' thick, for 3-in. pipe at 400 F tem perature difference between the pipe and the surround ing air? Heat Insulation factor for Asbestos Sponge at 400 F temperature difference from table is 1.043. Unit beat loss from "Base Thermal Tables" for 2' thickness
for 3-in. pipe at 400 F temperature difference between pipe and surrounding air is 0.313 from table bn page 912. 0.313 x 1.043 = 0.326 BTU per square foot per F temperature difference between pipe and air per hour. The outer diameter of a 3*in. pipe is 3.5'. Twice the thickness of the insulation is 4*. The outer diameter of the insulation is therefore 3.5 x 4 or 7.5'. 0.32o x
400 x 3* -- -- 60.9 BTL' per square foot of canvas
surface per hour.
From the bottom of page 8. Bulletin 102-A. for a heat loss of 60.9 BTU follow the vertical line until it intersects the 7.5* line ^interpolated between the 6' and the 8' lines:, then follow horizontally to the left to where this line intersects the 37 F temperature difference line. Add 80 F to 37 F temperature dif ference to obtain 117 F. the canvas temperature for 80 F air.
HEAT INSULATION DATA
CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING
Nominal 1" Thick
EFFICIENCIES, MEAT SAVINGS AND UNIT HEAT LOSSES
Sovingt are in 6. T. U. per lineor foot of pipe per hour. Unit lots** ere in B. T. U. per square foot of pipe surface per hour per UF. temperature
difference between pipe and surrounding air.
Pipe Size
tlMMUATUM DWCtCNCE f. UTWttN tlM AMD SUKKOUNOING AIK
100
150 900
250
300
450 ! 400 ' 450
500 550
W'
Efficiency Saving* . Unit Loe* . . .
75 27c i 77 3% . 78 9*7 j 80.3*7 814% j 82 4*7
83 5*7 ! 84 5*7 1 85.3*7 j 86 1*7
41 i
71 :
108 |
151 i
201 !
258 ,
328
406 |
49S
596
614 !
634
654 i
.674 ;
694
.715 :
735 I
755 I
.775 I
.795
, T Efficiency ... ' 76 0*7 : 78 0*7 79 5*7 i 80 8*7
! Saving*................. 1
51 |
88 :
133 I
186
. Unit Low
.|
584 !
.604 1
.623 [
643
--------------- ------------------------------------------ --^
. *7 Efficiency .
79 6*7
81 3*7
..i.
82 6*7 1 83 8*7
1" Savings .
65 1
113
170 j
237
: Unit Lom
.:
487 !
503 '
.S19 1
.535
82.0*7 j 83 0*7 . 84 0*7 84 9*7 85 8*7 , 86 S',
248 i
320 ;
407 j
S03
614 ;
740
.662
.682 I
.702 |
.721 ;
.741 j
.760
:
-
!
`
.
84 7* ; 316 .551
8S 6*; , 86 5%
87 3%
406 '
516 j
638
.567 i
583 !
599
88 0% 778 615
88 7% 936 .631
_f/ ,, : % Efficiency ------ \ 78.9*7
1 Va ; Saving* ............ 1
80
[ Unit Lots
. 494
80.6*7 1
139 .511 i
82.0*7 1 83 2*7
209 | S28 j
293 544
84.2%
390 561
BS 1*7 502
.578
86 1*7 ' 86 9% I 87 6%
639 1 792
966
.595 [ .612 j
628
88 3% 1164
. 645
- i / ! r< Efficiency .
1 !/2
Saving*
; 81 0*7 | 93
. | Unit Lom................:
440
82.5*7 160
455
83 8*7 242
470
84 9*7 338 485
8S 7*;
450 .500
86 6% 578
.515
87.5% 736
.529
88 2%
911 -14
88 9% 1112 .559
89 5%
1338 .574
j *7 Efficiency..........j 82.2*7
83 7*7
84.9%
85 9*7
86 8*7
87.5%
88 4%
89 1%
89 7%
90 3%
2 1 Saving* ...............
116
200 301
421
561
721
918 1136 1387 1670
, Unit Lom............. !
.404
.418
431
445
458 472
485
499
.512
. S26
,, ,, i *7 Efficiency . i 82 8*7
2V2 i Saving* ............... ! Unit Lom ...
139 .384
, *7 Efficiency . !
3 I Stviagi..................1
[ Unit Loss
|
^,.,,,1 *7 Efficiency........... j
31/2
Saving*...................... j
| Unit Lom............. !
83.0*7 16? .373
85 6*7 195
.314
84.3*7 240
.397
84.5*7 288
.386
86.6*7 335 324
8S 4% 361 410
85 6% 435 .398
87 2% 477 335
86 4% SOS 423
86 6% 608 .411
88.6% 70S
.345
87 2*7 673 436
87 5% 811
.423
89 4% 939 .356
88 0% 866 449
88 2% 1044 436
90 0% 1207 .366
88 8% 1130 461
89 0% 1329 .449
90 7% 1537 .376
89 5% 1367 474
89 7% 1648 461
91 3% 1904 .387
90 1% 1669 487
90 3% 2014 .474
91 8% 2325 .397
90 7% 2011 SOO
98 8% 2428 486
92 3% 2019 .408
; *7 Efficiency......... 84 0*7
85.3*7
86 4%
87.3*7
88 2*7
88 9%
89.7%
90 3%
90 9%
91 4%
4 1 Saving*....................
214
368
554
775
1034
1332
1698
2016
2575
3106
Unit Lom................
.346
.358
.369
.381
.393
.405
.416
.428
440 . 451
4V4"
*7 Efficiency......... Saving* .................. Unit Lom................
86.0*7
241
.299
87.2% 415
.309
88 2% 624
.319
89.0% 872
.329
89.7%
1162 .339
90.3% 1495 .349
91 0% 1905
.358
91 6%
2362 .368
92.1%
2885 .378
92 6% 3479
.388
5"
a." O
7 Efficiency......... Savings.................... Unit Lom................
i eieaey......... Savings....................
Unit Lom................
84.0*7 260
.340
83 9*7 305 .338
85.4% 446 .352
85 3% 526 .350
86 5% 675 363
86.4% 793 .361
87 4% 945 .375
87 3% mi .373
88 2% 1262 .386
88.1% 1486 .385
88.9% 1627 .398
88.8% 1916 .397
89.7% 2075 .410
89.6% 2447 .408
90.3% 2576 .421
90.3% 3040 .420
90 9% 31S2 433
90 9% 3720 .432
91 5% 3805 .444
91.4% 4494 .443
Flat 1 % Efficiency......... > 86 4*7
v--|8KlL.Ilf
87.6*7 318
.301
88.5*7 1 89 3%
1 476 ' 668
i
312 !
.322
89 9% 890
.332
90.5% 1145 .343
91.2% 1458
.353
91.7% i 92.2%
1808
2208
.363 |
.373
92 6%
2661 .384
All date from Mellon Institute, University o( Pittsburgh tests.
2-4 INS 104.A O05
HEAT INSULATION DATA
CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING
Nominal 2" Thick
EFFICIENCIES, MEAT SAVINGS AND UNIT HEAT LOSSES
Sovmq! or* in 8. T. U. p*r linear foot of pipe per hour. Unit lorn* ore in B. T. U. per square foot of pipe surface per hour per aF. temperature difference between pipe and surrounding air.
TIMFERATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNDING AIR
Size ;
. too
i 150
200
250 900 350
400 490
! % Efficiency . . .
W
Savings.................... j 1 Unit Lon . . !
81 8% 45
.451
' 83 4*7 77
: .465
84.6*7 115
478
! % Efficiency... . . 83.2; : 84.6%
85.8*7
%" ! Savings .................
56
96 144
1 Unit Loes...........
408
421 '
.433
, % Efficiency . . ! 85.2'"t | 86 s*;
I"
Savings ................. ,
70 ;
120
{ Unit Loss . . . ;
352 :
363
87 5*7 180
.374
1 % Efficiency . . . 85.8%
VA" I Unit Loes................ j
.331
i 87.1*7 ! 341
88 0*7 .352
1 % Efficiency . . ' 87 7%
V/f ; Savings ............ .
101
: Unit Loos ............. j .285
1 % Efficiency.. . . : 88 o%
2"
Unit Loo*............. j
.272
1 88 7*7 ' 172 i .294
89 ir;
1 .280
89 6*7 258 303
89.9*7
289
2W
% Efficiency... . : 89.3%
Savings . .
! 150
Unit Loes . . 1 .239
90 2*7 257
.247
91.0*7 385 254
% Efficiency..
1 89 0*7
3" Savings ............
179
! Unit Loos ............
.241
90 o*> 307 .249
90.8*7 461 .256
ZW
% Efficiency . . Savings ....... Unit Loss . .
90.0% I 205 1 .217
90 9*7 351 .224
91 6*7 526
230
4"
% Efficiency . Saving* . . Unit Loss
89 7 % 228
223
90 6*7 390
230
91 3*; 585
237
AW
% Efficiency.. . Savings
Unit Loss .
89.0*7 250
.236
89 9*7 427
.244
90 7*7 641
.251
% Efficiency.. .
90.0*7
90.8*7
91 6*7
5" Savings....................
278
477
715
Unit Loss . . .
.213
220 .226
% Efficiency.. .
90.2*7
91.1*7
91 8*7
6" Savings...............
328 562 843
.205
.21!
.218
7" Savings . ... Unit Loes ...
375 .199
91 3*7
642 . 90S
963 212
% Efficiency......... 90.6*7
91.4*7
92 1*7
8" Saving*....................
421
721 1083
Unit Loss.............
.194
200
206
% Efficiency.......... 91.1*7
91.9*7
92 5*7
9" Savings .................
469
803 1206
Unit Loes...............
.182
.188
193
10"
%f Efficiency.......... Savings ..................
Unit Loss................
91.0*7 520
183
91.8*7 889 .189
92 4*7 1336
' .194
12"
% Efficiency.. . Savings ................. Unit Loes................
91.2% 611 .176
92.0*7 1046
.182
92.6*7 1572
.187
14"
% Efficiency..........
Savings.................... Unit Loss...............
90.9% 664
.182
91.7*7 1138 .188
92 3*7 1709 .194
16"
18"
Flat Vertical
2"TVk.
% Efficiency......... Savings.................... Unit Loss...............
% Efficiency..........
Savings .................. Unit Loos................
% Efficiency..........
Savings .................. Unit Loss...............
91.0*7 754
.179
91 0*7 842 .177
92.6*7 199
.159
91.7*7 1291 . 18S
91.8*7 1443 . 183
93.2*7 339 .164
92 4*7 1940 .190
92 4*7 2171 . 188
93.7*7 507
.169
8S 6*7 161 492
86.7*7 200 446
88 3*7 2S0
.385
88 8*7
.362
90 3*7 359 311
90 6*7
297
91.6*7 S36 262
91 4*7 642 264
92 2*7 733
.237
91 9*7 816 244
91 3*7 895 . 2S9
92.2*7 997 .233
92 4*7 1177 224
1345 218
92 6*7 1512 213
93 1*7 1684 199
93 0*7 1866 200
93 2*7 2196 . 193
92 9*7 2392 199
93 0*7 2714 .196
93.0*7 3038 . 194
94.2*7 705
.174
86.5*7 213
.506
87.5*7 265 459
89.0*7 332 .396
89.5*7
.372
90 9*7 477 .320
91.2*7 589 306
92.1*7 711 269
92 0*7 853 .271
92 7*7 974 244
92 4*7 1084 251
91 9*7 1190 266
92 7*7 1326 240
92 9*7 1566 231
93 0*7 1791 224
93 1*7 2013 .219
93.5*7 2242 . 20S
93.5*7 2486 206
93 7*7 2928 .198
93 4*7 3190 .205
93.5*7 3622 .202
93.5*7 4056 . 199
94.6% 936 .179
87.2*7 273 520
88.2*7 340 472
89.7*7 425 .407
90 1*7 532
.383
91 4*7 611 .329
91 7*7 755 314
92 6*; 912 .277
92 4*7 1094 .279
93 1*7 1249 251
92 9*7 1392 258
92 4*7 1529 274
93 17 1704 247
93 37 2013 237
93 4*7 2302 231
93 67 2590 .225
93 9*7 2885 211
93 9 7 3200 .212
94.1% 3770 .204
93.8% 4109 .211
93.9% 4667 .208
93.9% 5227 .205
94.9% 1201 .185
88.17 346 .533
89 0*7 431 484
90 4% 539 418
90.8% 674
` .393
92 0% 774
.338
92.3% 958 .322
93.1% 1157 .284
93 0% 1389 287
93 6% 1587 257
93 4% 1769 265
93 0*7 1945 .281
93 6% 2167 .253
93.8% 2561 .243
93 9% 29.iO 237
94 1% 3298 .2-1
94 4% 3674 .216
94 3% 4078 .217
94.5% 4807 .209
94.3% 5241 .217
94 3% 5957 .213
94 4% 6674 .211
95.2% 1524 . 190
88 7% 427 . 547
89 6*7 531 497
90 97 664 429
91.3% 832 403
92 5% 955 .347
92.7% 1183 .331
93.5% 1429 292
93 4% 1717 294
94 0*7 1962 .264
93 8*7 2189 272
93 4% 2408 289
94 0*7 2682 260
94 2% 3173 . 250
94 3% 3631 .243
94 4% 4089 .237
94 8% 4555 222
94 7% 50S9 .223
94 9% 5963 .215
94 6% 6506 .223
94.7% 7399 .219
94 8% 8193 .216
95 5% 1883 .195
All dare from Mellon Institute, University of Pittsburgh tests.
500
89 47 519 561
90 2% 646 510
91 4': 808 440
91 9*7 10*3 .413
92 97 1162 35S
93 2*7 1441 339
93 9*7 1740 .299
93 8% 2093 .302
94 4% 2391 271
94 2*7 2669 279
93 8% 2939 296
94 4% 3272 .267
94.6% 3873 .256
94.7% 4435 .249
94 8% 499S .244
95 1% 5565 .228
95 0% 6192 229
95 2% 7294 .220
95 0% 7960 .228
95.1% 9054 225
95 1% 10153 .222
95 8% 2295 .200
550
90.0% 623 S74
90 8*; 77S 522
91 9% 970 451
92 3% 1217 424
93 3% 1396 364
93 6*; 1731 .348
94 3% 2091 307
94 2% 2517 309
94 7% 2877 277
94 5*7 3213 286
94 2% 3539 304
94.77 3942 .273
94 9*7 4666 263
95.0% S345 . 2S6
95.1% 6021 .250
9S.4% 6712 .233
95 4% 74S8 .234
95.5% 8789 .226
95.3% 9609 .234
95 4% 10935 .230
9S 4% 12266 .227
96 1% 2760 .205
HEAT INSULATION DATA
CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING Nominal 2W Thick
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES
Saving* art in B. T. U. ptr linear feet of pip# ptr hour. UnH lossy art in B. T. U- ptr square feet ef pipe surface per hour per F. temperature difference between pipe and surrounding air.
Pipe Size
: 100
TEMFEIATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNDING AIR
ISO 200 ] 250 300
350 400 450
w
'( Efficiency.
Savings . . Unit Loss .
O Efficiency. Savings Unit Lees
' r Efficiency.
Sevings . . . Unit Lou
1 Va
O Efficiency. Sevings . . .
Unit Lou .
c'r Efficiency.
V/i" ! Sevings . . . Unit Lou . .
O Efficiency.
2" Sevings. ... Unit Lou. . .
2'/a'
O Efficiency.
Sevings Unit Lou . .
a1/*'
O Efficiency. Sevings Unit Lou .
cc Efficiency.
Sevings . . . Unit Lou. .
0 Efficiency. Sevings . . . Unit Lou .
4%'
0 Efficiency. Sevings Unit Lost .
O Efficiency Sevings
Unit Lou . . .
`7 Efficiency Sevings .
Unit Lou . .
0 Efficiency. Sevings...........
Unit Lou. . .
97 Efficiency. Sevings. . .
Unit Lots .
97 Efficiency. Sevings ....
Unit Lott.. .
10'
9c Efficiency. Sevings..........
Unit Lots. . .
12'
97 Efficiency.
Sevings........... Unit Lou. . .
14'
97 Efficiency. Sevings........... Unit Lou.. .
16'
<7 Efficiency. Sevings.......... Unit Lou . . .
18"
97 Efficiency. Sevings...........
Unit Lou. .
Fiat Vertical 2 Tb'k.
97 Efficiency. Sevings ...
Unit Lou . . .
: 82 7'7
84 20
1 45 . 78
. 428
441
85 4 <7 i 86 60 i 57 : os
1 .356
367
' 86 60 . 87 80
1 71 , .319
122 329
87. *'7 ; 89 [ 294
88 5'; 152
303
88.8r7 102 259
89 80 174
267
i 89 3*7 ! 126
, 243
90 20 216
.250
89.30 150
.239
90.20 257
.246
90 4*7 182
.211
91 497 312
218
91.297 208
192
92 OO 355 .198
91 0O 232 194
91 897 396
200
91.70 257
.177
92 40 439
183
91 4-7 283 .183
92 IO 483
189
91.60 333 176
92 40 S70 181
j
92.30 430 .158
92 40 476 155
92.397 527 156
92 60 620 . 149
92.397 675 .153
92 4 97 766
. 150
92.50 856
. 148
93.997 201
. 130
92 90 726 163
93 IO 814 . 160
93 OO 901 161
93 20 1060 .154
93 097 1154 .158
93 197 1309 155
93 IO 1464 .153
94 SO 343 .134
85 4 0 : 86.40 r. 87 20
117 '
162 `
215
454 466 479
87.697 147
.377
88 40 204
.388
89 20 270
398
88 70 182
339
89 40 253
.348
90 IO 336
.357
89 4'7 228
312
90.10 317 .321
90.70 420 330
90 50 261 . 275
91 20 363
282
91 80 481
290
90 9 0 323
258
91 60 449 .265
92.10 595 273
91 OO 385 .254
91 60 536
261
92 IO 711 269
91 90 466
.224
92 50 649
231
93 OO 862
.237
92 60 532
.204
93 IO 740
.210
93.50 983
.216
92 4 0 593 206
93 OO 825 212
93 40 1096 .218
93 00 658
. 188
93 SO 916 194
94 OO 1217
199
92 80 724
194
93 30 1009
200
93 70 1341
.205
92 90 8S4
187
93 50 1191 192
93 90 1S83
198
93 50 1100 168
93 70 1221 .164
93 50 13S2 166
93 80 1591 . 1S8
93.50 1732 .163
93 70 1966 .159
93 7% 2200 .157
94 9 0 513 138
94 0O 1534 173
94 10 1703 .169
94 00 1887 170
94 20 2221 .163
94 IO 2422 .167
94 IO 2748 164
94 20 3075 . 162
95.30 713 . 242
94 40 2041 .178
94 50 2266 174
94 40 2512 .175
94 60 2958 .168
94.50 3226 . 172
94 50 3663 . 169
94.60 4102 .166
95.60 946 .146
87 90 275 492
89.80 346 409
90.70 430 367
91.30 538 339
92 20 616 298
92.60 763
.280
92.60 912
.276
93 40 1105 .244
93 90 1260 222
93.80 1406 .224
94.30 1561 .205
94.10 1722 211
94 30 2034 203
94 80 2623 . 183
94 9 0 2913 .179
94 8 0 3231 . 180
95 OO 3806 .173
94.80 4152 .177
94.90 4717 .174
94 90 5283 .171
95.80 1212 151
88.70 349 . SOS
90 SO 438 420
91.30 544
.377
91 80 682 348
92 80 780 306
9310 967 .287
93 IO 1157 .283
93.80 1402 251
94 40 1599 .227
94 30 1786 230
94 70 1982 .210
94 50 2188 .217
94.70 2586 .208
95.20 3338 .187
95 30 3707 .183
95.20 4114 . 185
95.40 4849 .177
95.20 5292 .182
9S.30 6015 178
95.30 6740 .176
96.10 1538 .155
89 30 430 518
9100 539 430
91 80 671 .386
92 30 841 .357
93 20 962 314
93 SO 1193 .295
93 50 1429 .291
94 20 1732 .257
94 70 1976 233
94 60 2208 236
9510 2451 216
94 90 2707 .222
95 OO 3201 .214
95 50 4135 . 192
95 60 4594 .188
95 SO 5101 .190
95 70 6013 .182
95.50 6566 .187
95 60 7467 .183
95 6 0 8370 .180
96 40 1899 .159
All date from Mellon Institute, University of Pitttbvtih tests.
500
90 OO S22 530
91 SO 655 441
92 30 816 396
92 80 1023 366
93 6 0 1171 321
93 90 1452 302
93.90 1740 .298
94 602110 264
95.10 2408 239
95 OO. 2691 242
95 4 0 2988 .221
95 20 3301 .228
95 4 0 3905 219
9S 80 5048 .197
95 80 5610 .193
95.80 6232 .194
95 90 7344 .187
95. SO 8028 .191
95 90 9132 .188
95 90 10240 18S
96 6 0 2313 .163
550
90 627 543
92 OO 786 4S 1
92 7^ 979 40S
93 20 1228 375
94. OT UQS 329
94 30 1744 310
94 30 2091 306
94 90 2537 270
95 4 0 289$ .245
9S 30 3238 248
95 70 3595 227
9S 50 3974 233
95 60 4702 225
96.00 6080 202
96 IO 6762 197
96 IO 7513 .199
96 20 8864 . 191
96.10 9686 196
96 irr 11220 192
96.20 12365 . 189
96 80 2781 167
HEAT INSULATION DATA
CAREY SUPER-LIGHT 85% MAGNESIA PIPE COVERING
Nominal 3" Thick
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES Sovings are in 8. T. U. per iineor foot of pipe per hour. Unit fosse* are in B. T. U. per square foot of pipe surface per hour per *F. temperature
difference between pipe and surrounding air.
Size
. <00
TEMPERATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNDING AIR
150 200
250 , 300 ! 350 ; 400
450
500 550
' Efficiency.. Unit Loss . . .
84 O'. i 85 4',
' 79
397 I
409
'. Efficiency
Savings
.
Unit Loss .
' 86 3',' 1 87 5',
58 99
332 :
342
. ', Efficiency
87 6', 1 88 7',
1" Savings . .
72 123
; Unit Loss . . .
296 305
. ' Efficiency
1%" Savings . . .
Unit Loss
..
88 4', 90
270
89 5'; 154
278
1i
*
jS
', Efficiency . Savings .
Unit Loss
89 6'.
90 S' ,
103 j
176
240 :
247
2"
' ', Efficiency . Savings
; Unit Loss .
90 2' : 91 r,
127 '
218
222 j
229,
2Y2"
`. Efficiency .
Savings
.
Unit Loss .
: ' e Efficiency . .
3" i Savings ; Unit Loss . .
90 S', 91 3', 152 260 213 220
91 3'i 184
191
92 r. 314 197
1 1, Efficiency . . 3W' ; Savings . .
Unit Loss
92 r; 210 173
92 8`; 358
178.
4"
'. Efficiency
; Savings Unit Loss
92 O' . 234
173
92 7', 400
178
4V2"
'. Efficiency
Savings
.
Unit Loss
5"
\ ' i Efficiency . \ Savings
i Unit Loss .
92 S' . 259 160
92 4', 286 162
93 2'. 443 165
93 0'. 488 167
6"
'. Efficiency Savings . Unit Loss .
92 6'. 337 155
93 3', S76
160
7"
', Efficiency
Savings
.
Unit Loss . . . .
93 0', 386 146
93 6', 658
1S1
1, Efficiency.. . 93 r;
93 7'
8" Savings . . .
433
740
Unit Loss
142 146
9"
', Efficiency . . Savings . ... Unit Loss . ...
93 3'i 481 . 138
93 91 821 .142
10"
`, Efficiency .
93 3r;
Savings .
533
Unit Loss
.1
136
93 91 910
.140
12"
', Efficiency . . i 93 4',
Savings.................... :
626
Unit Lots.............
.132
94 01 1069 .136
14"
1 Efficiency..........i Savings ................
Unit Loss........... 1
93 3S 682
.133
93 91 1166
.137
16"
1 Efficiency........... i Savings ................ 1
Unit Loss ... .
93 4-", 774
130
94 of; 1323 . 134
18"
1 Efficiency.. . i Savings.................... : Unit Loss................:
93.51
866 . 128
94.11
1480 . 132
Flat Vertical 3" Th'k.
1 Efficiency......... : Savings ............... Unit Loss...........
94 91 203
.110
95 31 346
.113
; 86 4', ; ns : 421
i 88 4'. >48 352
; 89 5'. 184
; 3i4
1 90 2', ! 230 1 286
' 9i 2-; 263 254
91 8', 325 235
92 O', 389 226
92 7', 470 203
93 3' 536 184
93 3'. 598 183
93 7', 663 170
93 6'. 731 172
93 8'; 861 165
94 11 986 . 155
94 2V 1108 151
94 31 1229 . 147
94 4'; 1364 . 144
94 s'; 1603 140
94 4i 1748 141
94 S'; 1984 138
94.51 2220 .136
95 7i 517 .117
, 87 3' , 1 164
! 433
88 1', i 217
| 44S
! 89 2'; 206
362
89 91 272
372
! 90 2', ' 256 ! .323
\ 90 9',
! 320 ! 294
90.81 339 .332
91 51 424 302
91 8'i 366 262
92 41 484
269
92 3',' : 4S2
242
92 81 600
248
92 5'; 541
233
93 01 718 239
93 21 6S4
208
93 7' ,
868 214
93 8'; 746
189
94 21
989 194
93 7'i 832
189
94 2'. 1104
194
94 2',
923 174
94 61 1244
179
94 c; 1017
177
94 4' ,
1351 182
94 3','
94 6'.
1201
1595
. 169__ |
174
94 5f; 1374
160
94 91
1826 164
94 6i 1 S44
155
95 01 20S3 160
94 71 1714
. 1S1
95 11 2280
.155
94 81
1902 149
95 11 2531
153
94 91
2237 144
95 31 2978 148
94 81 2442 .145
95.21 32S1 .149
94 91 2771
. 142
95.31 3692
146
94 91
3101 . 140
95.31 4134 . 144
96 01 719
. 120
96.21 9S3
.124
, 88.7'', ! 278 | 458
I 90 51 i 348 j .382
| 91.31 1 433 ! .341
! 92 01 543 .311
1 92 81 620 276
93 3' , 768 2S5
93 41 920 246
94 01 1113 220
94 51 1268 .200
94 SI 1417 199
94 91 1571 184
94 8'i 1734 187
95 01 2048 179
9S.21 2345 169
95.31 2638 164
95 41 2930 160
95 51 3254 . 1S7
95 51 3830 .153
95 51 4182 .154
95 61 4752 .150
95 61 5321 .148
96 51 1221 .127
; 89
| 470
! 91 11 1 441 | 392
91 91 548 349
92.51 687 319
93 31 785 283
93 71 969 262
93 91 1166 .252
94.51 1411 226
94 91 1609 205
94 9'; 1798 .204
9S 31 1993 189
95 21 2202 192
95 31 2602 .184
95.51 2980 .174
95 71 3355 168
95.81 3727 .164
95 81 4141 161
95 91 4876 .157
95.81 5327 .158
95 91 6056 . 154
96.01 6787 . 151
96 71 1548 .130
, 90 11
! 482
91 6' , 543 402
92 4' , 675 3S8
93 O'. 84 7 327
93 71 968 .290
94 11 1201 268
94 3', 1440 .259
94.81 1743 232
9S 31 1987 210
95 31 2222 209
95 61 2464 194
95 51 2723 197
95-61 3220 189
9S 81 3690 .178
95 91 41S4 . 173
96.01 4617 . 168
96 r; 5132 .165
96 21 6044 .161
96 11 6607 .162
96 21 7514 . 158
96 21 8423 . 155
96 91 1910 .134
90 61
.494
1 92 11 : 659 ! 412
1 92 91 821
j 367
1 93 5', 1 1054
33S
94 r. 1176 298
94 51 1460 . 275
94 6`, 1753 265
95 11 2122 237
95 61 2421 21S
95.51 2707 . 21S
9S 9', 3003 . 198
95.81 3320 .202
95 91 3928 . 193
96 11 4501 .183
96 2'; 5070 . 177
96.31 5636 .172
96 31 6265 170
96 41 7385 16S
96 41 8074 .166
96 41 9186 162
96 51 10302 159
97 11 2326 .137
. 91 21 ! 631 [ .506
I 92 51 791
S 422
! 93 31 | 984 1 .376
93 8` r 1236 343
94 4- , 1412 30S
94 8'i 17S4 281
94 91 2106 .272
95 4' , 2551 243
95 81 2909 .221
95 81 32S6 220
96 11 3612 203
96 0' r 3994 .207
96 2', 4727 198
96 41 5421 187
96.4'; 6105 . 182
96 51 6790 .177
96 61 7551 174
96 6` ; 8904 .169
96.61 9738 . 170
96 71 11008 . 166
96 71 12432 163
97 31 2795 .141
All dare (torn Mellon Institute, University of Pittsburgh rests
HEAT INSULATION DATA
BASE THERMAL TABLE
1" Thickness
EFFICIENCIES, HEAT SAVINGS ANO UNIT HEAT LOSSES
Savings ara in B. T. U. par linear foot of pip* par hour. Unit losses aro in B. T. U. par square foot of pipa surface par hour per F. temperature difference between pipa and surrounding air.
Pipe Size
j.
TEMPERATURE DIFFERENCE *F. 8ETWEB4 PIPE AND SURROUNDING AIR
too | ISO ! 200 1 250 ji
300
350 400
450
500
5S0
i % Effideney . . . ! Saving*................ | Unit Loo*...........
W
' % Effideney ... Saving*................ Unit Loss............
75.2% 1 76.7% 41 70
0.614 j 0.643
77.0% i 78.4%
51 J
87
0.558
0 584
78.3% 106
0.672
80.2% 136
0 610
79.4% 148
0.701
81.0% 187
0.637
80.5% 199
0.730
81.9% 249
0 663
81.5% 257
0.759
82.9% 322
0.689
82 4% 324
0.788
83.7% 405
0.716
83.2% 400
0.817
84.5% 501
0.742
84.0% 490
0.846
85.3% 614
0.768
8* 8% 5*0
0.875
86 0% 737
0,795
% Effideney . ..
78.5%
79.8%
81.2%
82.3%
83.2%
84.0%
84 8%
85.6%
86.3%
87.0%
1' Savings................
64 109 167 233 311 401 505 625 766 921
Unit Loos............
0.511
0.535
0 559
0.584
0.608
0.632
0.6S7
0.681
0.705
0.730
r U/<'
% Effideney ... Saving*................ Unit Los*............
79.9% 81
0.470
81.2% 138
0.492
82.5%
211 0.514
83.4% 294
0 537
84.3% 393
0.559
8S.1% 507
0.581
85.9% 640
0.604
86.6% 792
0.626
87.3% 968
0.648
87.9% 1165
0.671
1%'
% Efficiency . . . Savings................ Unit Lots . . .
80.5% 93
0.4S0
81.7% 157
0.471
83.0% 240
0 493
83.9% 334
0.515
84.8% 446
0.536
85.6% 577
0.558
86.3% 727
0.S80
87.3% 924
0.601
87.7% 1102
0 623
88.3% 1327
0.64S
2"
% Effideney . . .
Savings................ Unit Lose ......
81.5%
11S 0.421
82.5% 194
0 441
83 8%
297 0 462
84 6%
413 0.482
85.5% 5S4
0.502
86.3% 716
0.523
87.0% 905
0.543
87.7%.
1119 0.S63
88 3% 1371
0.583
83 9% 1651
0.604
2Vz'
% Effideney ... Savings................ Unit Low............
82.1% 138
0.399
83.1% 233
0 419
84 4% 357
0 438
85.3% 498
0 457
86.1%
665 0.477
86.8% 860
0.496
87.5% 1089
0.515
88.1% 1347
0.535
83.8%
1651 0.554
89 3% 1991
0.573
3'
% Effideney . .. Saving*................
82.6% 167
83.6% 282
84 9% 431
8S 7% 601
86. S% 804
87.2% 1041
87.9% 1316
88.5% 1629
89 2%, 1999
89 7% 2411
Unit Los*............
0 382
0 401
0 419
0 438
0.456
0.475
0.493
0.512
0.530
0.549
3V4'
4' 4V2'
% Effideney . . . Savings................ Unit Low............
% Effideney . . .
Saving*................ Unit Los*............
% Effideney . . . Savings ......... .. Unit Los* ....
83 0% 189
0.371
83.2% 212
0.363
83.4% 234
0.355
84 0% 321
0 389
84 2% 359
0.381
84 4% 39S
0 372
85.1% 489
0.407
85.3% S47
0.399
85 6% 605
0.390
86 0% 682
0 425
86.2% 765
0 416
86 3% 843
0 407
<6.8% 913
0.443
87.0% 1024
0.434
<7.2% 1134
0.42S
87.5% 1183
0.461
87.7% 1324
0.452
87.9% 1466
0.442
88.2% 1496
0.479
88 3% 1674
0.470
88.5% 1855
0.460
88.8% 18S3
0.497
88.9% 2076
0.488
89.1% 2295
0 477
89 4% 2275
0.515
89.5% 2550
0.505
89.7% 2820
0 494
89.9% 2739
0.533
90.1% 3072
0.523
90.2% 3399
0.512
5" % Effideney . ..
83.5%
84 5%
8S. 7%
86 5%
87.3%
88.0%
88.7%
89 2%
89.9%
90.3%
f
Saving*................ Umc Lots............
2S8 0.349
436 0 366
670 0 383
933 0 400
1257 0.417
1626 0.434
2058 0.4S1
2547 0 468
3131 0 485
377S 0.502
6" % Effideney . .. Saving*................
83.9% 306
84.7% 514
86 0% 791
86 7% 1103
87.5% 1481
88 2% 1918
88.9% 2431
89 4% 3011
90.0% 3704
9C.5% <478
Unit Los*............
0.339
0.3S6
0 372
0 389
0 406
0.423
0.439
0.4S6
0.473
0.490
7' % Effideney . . . Saving*................
84.0% 3S0
84 9%' S88
86.1% 902
86 9% 1264
87 6% 1693
88.3% 2195
89 0% 2783
89.5% 3449
90.1% 4245
90.7% 5136
Unit Loss............
0.332
0 349
U 365
0 382
0.398
0.415
0.431
0 448
0.465
0 481
8" % Effideney ... Savings................
84.1% 392
85 0% 661
8`> 2% 1013
87.0% 1422
87.7% 1905
88.4% 2471
89.0% 3126
89.6% 3886
90.2%. 4775
90.7% 5779
Unit Loss............
0.327
0 343
360
0 376
0.393
0.409
0.425
0.442
0 458
0.475
9' 10'
,2-
% Effideney ... Saving*................ Unit Loo*............
% Effideney ... Savings................ Unit Loo*............
% Effideney . . .
Savings................ Unit Loo*............
84.2% 434
0.323
84.3% 482
0.319
84.3% S67
0.314
85.1% 731
0 339
85.2% 813
0.335
85.3% 958
0.330
8o.2%, 1123
0 356
86 3% 1245
0.351
86 4% 1467
0.346
87 0% 1577
0.372
87.1% 1749
0 367
87 2% 2056
0 361
87.8% 2115
0.388
87.9% 2347
0.383
88 0% 2762
0.377
88. S% 2745
0.404
88.6% 3048
0.399
88.6% 3590
0.393
89.1% 3474
0.420
89.2% 3859
0.415
89.3% 4576
0.409
89.7% 4321
0.437
89.8% 4803
0.431
89.9% 5667
0.424
90 3% 5311
0.453
90.4% 5906
0.447
90. S% 6972
0.440
90.8%, 6417
0 469
90.9% 7138
0.463
91.0% 8431
0.4S6
14'
% Effideney .. . Saving*................ Unit Loos............
84.3%
615 0.312
85.3%
1040 0.327
86 4% 1595
0 343
87.2% 2236
0.3S8
88.0%
3007 0.374
88.7%
3910 0.390
89.3% 4960
0.405
89.9%
6180 0.421
90.S%
7590 0.436
91.0% 9203
0.452
16'
% Effideney . .. Savings................ Unit Loo*............
84.3% 695
0.309
85.3%
1177 0.324
86.4% 1807
0 340
87.2% 2S37
0.355
88.0%
3413 0.371
88.7%
4443 0.386
89.4%
5638 0.401
89.9% 6991
0.417
90.5% 8636
0 432
91 0% 10475 0.448
18'
Flat Vertical
1' Th'k
% Effideney . .. Saving*................ Unit Low............
% Effideney ... Saving*................ Unit Low............
84.4% 780
0.306
86.3% 184
0.292
85.3% 1322
0.321
87.3% 314
0.306
86.5% 2031
0.337
88.1% 476
0.320
87.2% 2840
0.3S2
88.8% 664
0.336
88.0% 3825
0.367
89.4% 88S
0.350
88.7% 4981
0.383
90.0% 1146
0.365
89 4% 6325
0.398
90.5% 1448
0.380
89.9% 7845
0 414
91.0% 1798
0.394
90.6% 9696
0.429
91.5% 2191
0.409
91.1% 11768 0.444
91.9% 2054
0 424
All dmte from Mellon Institute. University of Pittsburgh tests.
HEAT INSULATION DATA
BASE THERMAL TABLE
IVa" Thickness
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES
Savings are in B. T. U. per linear feet ef pipe per hour. Unit losses ore in B. T. U. per square foot of pipe surface per hour per F. temperature difference between pipe end surrounding air.
Pipe
size *
TEMPERATURE DIFFERENCE *F. BETWEEN PIPE AND SURROUNDING AIR
100
ISO 200 ; 2SO
300 350 400
4SO j 500 j 390
; % Efficiency . . .
\L" : Savings................
/z | Unit Los*............
79.2% 43
0.515
80. S% 73
0 538
1 81.9% | 82.8%
| 112 |
1SS
1 0.562 1 0 585
83 8% ! 84 6%
207 ;
267
0 609 | 0 632 t
85 3% 1 86 0%
336 1
414
0 656 ' 0.680
86.7% 506
0.703
87.4% 608
0.727
1 % Efficiency . . .
%/." 1 Saving*................. '* j Unit Loss............
81.0% 54
0.462
82.1% i 83 6% 1 84 3%
91 I
142
194
0.483 | 0.504 ! 0 S26
85 1% I 85 9%
258 !
333
0 546 : 0 568
86 6% , 87.2%,
419 :
517
0.589
0.611
87.9% 632
0.632
88.5% 759
0.653
! % Efficiency ... i 82.4%
1" Savings........... j
67
Unit Los*......... j
0.418
83.5% 1 84.7% j 85 6%
114 j
174 .
242
0 437
0 456 i 0 475
86 4% 1 87.0% ; 87.7%
323 I
415 1
523
0 494 | 0.513 | 0 532 |
88 3% 89.0%, ! 89 5%
64S j
789 :
948
0.5S1
0.S70 1 0.589
i
% Efficiency . . .
83.8%
84 8% | 86 0%
86 7% 1 87 S%
88.1%
88.7% 1 89.3%
89 8%
90.3%
1 Savings................
85
144 j
220
305
407 !
524
661 1
816
997 1197
Unit Lots............
0.378
0 396 ! 0 413
0 431 | 0 448 j
0 465 j 0 483 1 0.S01
0.518
0.536
1w
% Efficiency . .. Savings ................
Unit Loss............
84 5% 97
0.359
85.4% ! 164 |
0 375
86 5% 250
0 392
87 2% ! 87 9% ' 88.6% 1 89.2% : 89-9%
347 :
462 .
598 '
751 1
9S2
0 409 ' 0 425 ' 0 442 1 0 4$8 1 0.47S
90.3% 1135
0 492
90.7% 136S
0.508
, % Efficiency ... I 85 4% ! 86 2% 1 87 3%
\ Savings................ ;
121 |
203 1
3J0
UnitLoss... . 1 0 332 !
0 347 j 0 362
88 0% , 88 7%
429 1
574
0 378 i 0.393 i
89 3%
740 0 409
89 9<7 1 90 4%
934 1
1153
0 424 ! 0.439
90.9%
1410 0 455
91 3% 1697
0.470
2W
% Efficiency ... i
Savings...........
1
UnitLoss........... |
86.1%
145 0.311
86.9% 243
0 326
i 87 9% i 88 5% 1 89.2% 1 89.8% i 90.3% j 90.8%
' 372 :
517 j
689 :
890 '
1124 1
1388
0 340 : 0 35S 1 0 369
0.384 1 0.399 ; 0 413
91.3% 1699
0.428
91.8% 204S
0.442
% Efficiency ...
86.6% | 87 4% 88 4% : 89 !% ' 89 7%
90 2%- 90 8%
91.3%
91.7%
92.2%
3' Savings................
175
29S j
449
625
834
1077 ;
1359
1679
2057
2477
UnitLoss............ { 0.294 ! 0 308
0 321
0 335
0 349
0 363 : 0 376
0.390
0.404
0.418
1 % Efficiency ... i 87.0%
31A* ! Saving*................ !
199
/z | Unit Loss............ 1 0.283
87 8% ! 88 7% 89 3%
335 [
509 :
709
0 297 I 0 310 : 0 323
90 0% . 90 5% 91 0% j 91.5%
947 1224 1544 1910
0 336
0 349
0.363 1 0.376
92.0% 2341
0.389
92.4%
2815 0.402
1 % Efficiency ... i 87.3%
4' ! Savings................ j
222
I Unit Los*............ ; 0.27S
88.1% 375
0 288
1 88 9 % S70
0 301 :
89 6% . 90 2%
795 i
1062
0 314 : 0 327
90 7% i 91 2% ' 91 7%
1370 1
1729 !
2140
0 340 1 0 3S3
0.366
92.2% 2624
0.379
92.5% 3157
0.392
% Efficiency .. . : 87.S% ' 88.2% ' 89 1%
41/,'' i Savings .......... :
245 :
412
630
/z : UnitLoss............ 1 0.268
0 281 0 294
89 7%
876 0 306
90 4%
90 9%
1175
1S17
0 319 ' 0.331
91.4% 1 918% 1 92.3%
1916 '
2366 j
2902
0.344 ! 0.3S7
0.369
92.7%
3493 0.382
% Efficiency ... ; 87.6% ; 88 3% 89 3%
89 9% 90 S% : 91 0%
91.6%
92.0% I 92.4%
92.8%
1
5" l Savings................. i
271 ;
4S6 ;
698
970
1303 ;
1682
212S
262S
3221
3879
V
1 UnitLoss........ I 0.262 1 0 275
0 287
0 299
0 312 : 0 324
0.336
0.349 | 0.361
0.373
% Efficiency . . .
88 0%
88.6%
89 5%
90 1% ' 90 7%
91 3%- : 91.8%
92.2% I 92.6%
93.0%
6" Saving*................
321 1
538
824
1146 ;
1S36
1985 ;
2510
3104 1
3811
4601
Unit Lot*............
0.253 1 0 '65
0 277
0 289
0 301
0 313 1 0.325
0.337 l 0.349
0.361
] % Efficiency . . . 7" 1 Savings ..... . .
! Unit Loss............
88.1% 366
0.248
88.8%
615 0.2S9
89 7% 940
0 271
90 3% 1314
0 282
90 9% 1756
0 294 ,
91 4% 1 91.9%
2271 !
2874
0 306 | 0.317
92.3% 3SS6
0.329
92.8% 4369
0.341
93.2% 5278
0.352
% Efficiency ...
88.2%
88.9%
89 8%
90 4%
9j 0% | 91.5% : 92.0%
92.4%
92.8%
93.2%
8" Savings................
411
691
1056
1478
1975 '
2557 |
3228
4007
4914
5939
Unit Los*............
0.243
0 254
0.266
0 277
0 289 j 0 300 : 0.312
0.323
0.33S
0.346
% Efficiency . ..
88.3%
89 0%
89 8%
90 5% 91 1% ; 91 6%
92.0%
92.5%
92.9%
93.3%
9" Savings................
455
765
1171 1 1639 . 2194 |
2840
3S89
4456
5467
6595
Unit Loss............
0.239
0.250
0 262 1 0 273 ' 0 284 j 0.296
0.307
0.318
0.330
0.341
_. 10*
I % Efficiency ... ]
1 Savings.............. { i Unit Lom.......... :
50$ 0.235
89 1% . 90 0% ,
8S1 ;
1298
0.246 ! 0.257
90 6% 1818
0 268
91 2% 1 91 7% ! 92 1%
2435 i
3154 :
3987
0 279 j 0.291 i 0.302
92.6% 4953
0.313
93.0%
6079 0.324
93.4% 7336
0.33S
12" 14"
% Efficiency . . . Savings................ Unit Lot*............
% Efficiency . .. Savings................ Unit Los*............
88.5% 595
0.230
88.5% 645
0.228
89 2% ; 90 1% 1003 | 1530 !
0.241 | 0.2S2 |
90 7% 2138
0 263
89.2% I 90 1% j 90 7%
1088 1 1663 1
2325
0.239 | 0.250 1 0 261
91 2% 2865
0.274
91.3% 3119
0 272
91.8% 3716
0.285
91.8% 4047
0.283
92.2% 4726
0.297
92.3% 5124
0.293
92.6% 5842
0.308
92.7% 6373
0.304
93 1% 7175
0.319
93.1% 7811
0.31S
93. S% 8663
0.330
93.5% 9457
0.326
16"
% Efficiency . . . Savings................
Unit Loss............
88.6% 730
0.225
89.3% 1233
0 236
90 2%
90 8%
1886 !
2639
0.246 ' 0 257
91.3% 3S42
0 268
91.9% I 92.3%
4601
5826
0 278
0.289
92.7%
7211 0.300
93.2% 8889
0.311
93.6%
10767 0.321
18"
% Efficiency .. . Savings................
Unit Loss............
88.7% 820
0.222
89.4% 138S
0.233
90 2% ; 90 8%
2119
2955
0.244 | 0.2S4
91.4% 3969
0.26S
91.9% 5159
0.275
92.4%
6S36 0.286
92.8% 8094
0.297
93.2% 9984
0.307
93.6% 1209S 0.318
Flat Vertical
1H" Th'k
% Efficiency ... Savings................
Unit Los*............
90.4%
193 0 204
91 1% 328
0 214
91.7% 1 92 2%
495 689 0 224 1 0.234
92 6% 917
0.244
93.0% 1185
0.2S4
93.4% 1494
0.264
93 8% 1852
0.274
94.1%
22S3 0.284
94.4% 272S
0.29S
All dmtm from Mellon Institute, University of Pittsburgh rests.
HEAT INSULATION DATA
BASE THERMAL TABLE
2" Thickness
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES
Savings art in ft. T. U. per linear foot of pipe per hour. Unit losses are in ft. T. U. per square foot of pipe surface per hour per 9F. temperature difference between pipe and surrounding air.
TEMPERATURE DIFFERENCE *F. BETWEEN PIPE AND SURROUNDING AIR
Size ;
100 150 200 250 300 350 400 430
[ % Efficiency ... W I Unit Loss............
f % Efficiency . ..
%" ' Savings..................
' Unit Loss............
. % Efficiency . .. r 1 Savings................
' Unit Loss............
W
% Efficiency . . . Savings................
Unit Loss............
% Efficiency . ..
w
Savings................
' Unit Loss............
% Efficiency ... 2' Savings................
Unit Loss............
W
% Efficiency . .. Savings................ Unit Loss............
% Efficiency . . .
3' Savings................ Unit Loss............
zw
% Efficiency ... Savings................
Unit Loss............
% Efficiency . .. 4" Savings................
Unit Loss............
41/2'
% Efficiency . . . Savings................ Unit Loss............
% Efficiency . . .
5" Savings................ Unit Loss............
% Efficiency . . .
6' Savings................ Unit Lott............ % Efficiency . . .
7" Savings................ Unit Loss............
% Efficiency . ..
8" Savings................ Unit Loss............
% Efficiency . ..
9" Savings................ Unit Loss............
10'
% Efficiency . .. Savings................ Unit Loss............
12'
% Efficiency . .. Savings................
Unit Loss............
14"
% Efficiency . .. Savings................ Unit Loss............
16'
% Efficiency .. . Savings................
Unit Loss............
18'
% Efficiency ... Scvings................
Unit Lou............
Fiat
Vortical 2' Th'k
% Efficiency .. . Savings................
Unit Lou............
81 6% . 82.7%
45 .
75
0.457 . 0.478
83.3% ! 84.3%
56 [
94
0.407 i 0.425
84.7% i 85.7%
69 1 0.363 1
117 0.380
86.1%
86 9%
88 :
148
0.326
0.341
86.7% 100
0.307
87.6% 124
0.282
87.5% 168
0 321
88 3% 208
0 295
88.3%
148 0.262
89 0%
249 0.274
88.9% 179
0.245
89 6% 302
0 256
89.2% 204
0.236
89.4% 228
0.228
89 8% 343
0.247
90.1% 384
0.239
89 6%
2S1 0.222
90 3%
422 0 232
89.8% 278
0.216
90 4% 467
0 226
90.1% 329
0.207
90.7% S50
0.217
90.3% 376
0.201
90 9% 630
0.210
90.5% 422
0.196
91.0% 707
0 205
90.6%
467 0.192
91.1% 784
0.201
90.7%
519 0.189
91 2% 871
0.198
90.8% 611
0.184
91 4% 1027
0.193
90.9% 662
0.182
91.4%
1115 0 191
90.9% 749
0.179
91.5%
1263 0.187
91.0% 841
0.177
91.6% 1419
0.185
92.5%, 197
0.1S9
93.1% 335
0.166
83.9% 114
0.498
85.6% 145
0.443
86. t% 178
0.396
87.9% 225
0.356
88 4% 255
0.335
89 2% 316
0 308
89 8% 380
0.286
90 3% 4S9
0 268
90.6% 520
0.2S8
90.8% 583
0 249
91.0% 644
0 242
91.2% 713
0 236
91.5% 842
0.226
91 6% 960
0.220
91.8% 1079
0.214
91 9% 1197
0.210
91.9% 1326
0.207
92 1% 1564
0.201
92.1% 1700
0.199
92.2% 1928
0 196
92 2% 2167
0 193
93.6% SOS
0.174
84.8% 1S9
0.519
86.2% 199
0 462
87.4% 247
0.413
88.5% 312
0.371
89 1 % 3SS
0.349
89 8% 438
0.321
90.4% 527
0 298
90.9% 638
0.279
91.2% 723
0.268
91.4% 811
0 260
91 5% 893
0.2S3
91.7% 989
0.246
91 9% 1169
0.236
92.1% 1341
0.229
92.3% 1508
0.223
92 4% 1673
0.219
92. S% 1856
0 215
92 6% 2185
0.210
92.6% 2374
0.208
92.7% 2695
0.204
92.7% 3017
0.202
93.9% 702
0.181
6osoMr tc *
M O
9i
85.6% 212
0.540
86.9% 264
0 480
88.1% 329
0 429
89.2% 416
0.386
89 7% 472
0.363
90 4% 520
0.334
90.9% 703
0.310
91.4% 850
0.290
91.7% 965
0.279
91 9% 1082
0.270
92.0% 1197
0 263
92 2% 1327
0.2S6
92.5% 1S65
0.245
92.6% 1789
0 239
92.8% 2014
0.232
92 9% 2481
0.224
93.0% 2920
0.219
93.0% 3180
0.216
93.1% 3611
0.213
93.2% 4047
0.210
94.3% 933
0.189
All ctore itom Mellon Inttitute, University of Pittburh tests.
86 3% 273 .
0.561
87.6% 340
0.498
88.7% 423
0.446
89 7% 534
0 401
90.2% 609
0.378
90.9% 754
0.347
91.4% 906
0.323
91.9% 1097
0.302
92 1% 1246
0.290
92.3% 1394
0.231
92.5% 1S44
0.273
92.7% 1712
0.266
92.9% 2020
0.255
93.0% 2311
0.248
93.1% 2603
0.242
93.2% 2893
0.237
93.3% 3211
0.233
93 4% 3783
0.228
93.5% 4122
0.225
93.5% 4685
0.221
93 6% 5253
0.218
94 6% 1205
0.196
87.0% 342
0 581
88 3% 427
0.516
89 3% 532
0.462
90.3% 673
0 415
90.7% 765
0 392
91.4% 951
0 3S9
91.9% 1143
0.33S
92.3% 1382
0.313
92.6% 1570
0.301
92 8% 1759
0.291
92 9% 1948
0 283
93 1% 2161
0.275
93.3% 2552
0.265
93.4% 2922
0.257
93.5% 3284
0.251
93 6% 3650
0.246
93.7% 4054
0.242
93.8% 4807
0.236
93.9% 5212
0 233
93.9% 5926
0.229
94.0% 6649
0.226
94 9% 1518
0.204
87.6% <*22
0.632
88.5% 527
0.534
89 8% 656
0.480
90 8% 830
0.430
91.4% 967
0 406
91 8% 1172
0.372
92.3% 1411
0.347
92.7% 1707
0 324
93.0% 1940
0.312
93.1% 2174
0.302
93.3% 2403
0.293
93 4% 2667
0 285
93 6% 3153
0.274
93.8% 3612
0.267
93.9% 4072
0.260
94.0% 4S28
0.255
94.1% 5031
0.251
94 2% 5936
0.24S
94.2% 6475
0.242
94.2% 7328
0.238
94.3% 8227
0.234
95.2% 1881
0.211
500 550
80 2% 514
0 623
89.4% 643
0.5a3
90.4% 802
0 495
91.3% 1012
0.44S
91 7% 1153
0.420
92.3% 1432
0.385
92 7% 1725
0.359
93.1% 2088
0.335
93 4% 2376
0.322
93.5% 2663
0 312
93.7% 2945
0.304
93.8% 3270
0 29S
94.0% 3868
0.264
94. J% 4434
0.276
94.3% 4989
0.269
94.3% 5550
0.264
94.4% 6171
0.259
94.5% 7283
0.254
94.S% 7930
0.250
94.6% 9025
0.246
94 6% 10134 0.243
95 4% 2286
0.219
8S 8% 613
0 643
89 9 <7 771
0 S71
90.9% 963
0.512
91.7% 1215
0 460
92.1% 1385
0 434
92.7% 1721
0.398
93.1% 2074
0.371
93. S% 2513
0.347
93 7% 2854
0.333
93 9% 3201
0.323
94.0% 3542
0 314
94.1% 3933
0 305
04.3% 4466 0.273
94.4% 53S0
0.286
94 6% 6024
0.278
94 6% 6690
0.273
94 7% 7440
0.268
94.8% 8788
0.262
94.8% 9592
0.259
94.9% 10919 0 255
9S 0% 12269 0.2S1
95 7% 2763
0.226
?-4 INS TOd.A.Ol?
HEAT INSULATION DATA
BASE THERMAL TABLE
2 V:" Thickness
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES
Saving* ore in B. T. U. per linear foot of pipe por hour. Unit losses are in B. T. U. per square foot of pipe surface per hour per F. temperature difference between pipe and surrounding air.
Size
TEMPERATURE DIFFERENCE `F. BETWEEN PIPE AND SURROUNDING AIR TOO 150 200 250 300 350 400 450
1 % Efficiency . . . 1 83.2%
W | Savings................ i
45
[ Unit Loss............ : 0.417
% Efficiency . .. i Savings................ ! Unit Loss............ {
84.9% S7
0.368
% Efficiency . .. i 86.2%
1" Savings................
71
Unit Loss............ ! 0.329
f
1 % Efficiency . . . ! 87.4%
l]/' Savings................ i
89
I Unit Loss............ ; 0.294
iy2-
, % Efficiency . .. j
; Savings................ Unit Loss............ j
88.1%
101 0.274
% Efficiency . . . ; 89.0%
2"
Savings ................. !
126
Unit Loss............ ! 0.249
2W
% Efficiency . . . i
Savings................ Unit Los*............ {
89.6%
ISO 0.232
% Efficiency . . .
90.3%
3' Savings................
182
Unit Loss............
0.214
% Efficiency . . . |
Savings................
Unit Los*...........
90.6%
207 0.204
% Efficiency . ..
90.9%
4' Savings................
231
Unit Loss............
0.197
4i/2'
% Efficiency . . . Savings................ Unit Los*............
91.1% 255
0. 191
% Efficiency . . .
91.3%
S" Savings ..............
282
Unit Loss ......
0.185
% Efficiency . . .
91.6%
6' Savings................
334
Unit Loss............
0.177
% Efficiency . . .
91.8%
7" Savings................
382
Unit Loss............
0.171
% Efficient . . .
91.9%
8' 428
Unit Los* ..........
0.166
9" 10"
12-
1416-
% Efficiency . .. Savings .............. Unit Los*............
% Efficiency . . .
Saving*................ Unit Loss............
% Efficiency . . .
Savings................ Unit Loas............
% Efficiency ...
Savings................ Unit Loss............
% Efficiency . . .
Saving*................ Unit Loas............
92.1% 474
0.162
92.2% 527
0.159
92.3% 620
0.155
92.3% 673
0.153
92.4% 761
0.150
18-
|
% Efficiency . . . Saving*................
i Unit Loss............
Flat Vortical 2M' Th'k
% Efficiency ... Savings................
Unit Loss............
92.4% 854
0.149
94.0% 200
0.128
84.2% . 85.3% ' 86 1%
77 ;
116
162
0.436 1 0.455
0.473
8S. 7% 96
0.385
87.0% 147
0.401
87.5% 202
0 418
87.1% 119
0.343
88.0% 180
0.3S8
88.7% 2S1
0.373
88.2% 150
0.307
89.1% 228
0.320
89.7% 316
0.333
88.8% 171
0.287
89.7%
259 0.299
90.3% 360
0.312
89.7% 211
0.261
90.2% 2S3
0.243
90.5% 321
0.272
91.0% 385
0.253
91.0% 444
0.283
91.5% S34
0.264
90.9% 306
0.224
91.6% 465
0.234
92.0% 646
0.244
91.2% 348
0.214
91.9%
527 ' 0 223
92.3% 732
0.232
91.5% 390
0.206
92.1% S91
0.215
92 9% 824
0.224
91.6% 429
0.199
92.3% 653
0.208
92 7%
905 0.217
91.8% 474
0.194
92.5% 723
0.202
92.9% 1002
0 211
92.1% 559
0. IRS
92.7%
. 8S3 0 193
93 1% 1184
0 201
92.3% 639
0.179
92.9%
973 0.187
93 3% 1358
0.194
92.4%
718 0.174
93 0% 1094
0.181
93 5% 1527
0 189
92.5%
795 0.170
93.1% 1214
0.177
93 6% 169S
0.185
92.7% 885
0.166
93 2% 1344
0.174
93.7% 1880
0.181
92.8% 1042
0.162
93.4% 1586
0.169
93.8% 2210
0.176
92.8% 1132
0.160
93.4% 1724
0.167
93 8% 2405
0.174
92.9% 1282
0.157
93.4%
1955 0.164
93.9%
2729 0.171
92.9% 1440
0.155
93 5% 2196
0.162
93.9% 3055
0.169
94.4% 340
0.134
94.8% 512
0.140
95.1% 711
0.146
86.9% . 21S
0.492
88.1% 268
0.435
89.3% 334
0 388
90.3% 421
0.346
99.8% 477
0.324
91.S% 592
0 295
92.0% 711
0.274
92.5% 860
0.254
92.8% 976
0.242
93.3% 1099
0.233
93.2% 1212
0.226
93.3% 1343
0.219
93.6% 1S84
0 .'209
93 7% 1811
0.202
93 8% 2038
0.197
94 0% 2263
0 192
94.0% 2511
0 189
94.1% 2955
0.184
94 2% 3219
0.181
94.2% 3655
0.178
94.3% 4095
0.176
95.4% 944
0.152
87.S% 276
0.511
88.8% 344
0.452
89.9% 428
0.402
90.8% 541
0.3S9
91.3% 616
0.337
92.0% 763
0.306
92.4% 916
0 285
92.9% 1109
0.264
93 2% 1260
0.2S1
93.4% 1410
0.242
93 6% 1562
0.234
93.7% 1731
0.228
93.9% 2043
0.217
94.1% 2338
0.210
94.2% 2632
0.205
94.3% 2925
0.200
94.4% 3248
0.196
94.5% 3826
0.191
94. S% 4169
0.188
94.6% 4737
0.185
94.7% S313
0.182
95.7% 1219
0.158
88.1% 347
O.S30
89.4% 433
0 468
90.7% 540
0.417
91.3% 680
. 0.373
91.8% 773
0.349
92.4% 961
0.318
92.9% 1155
0.295
93.3% 1396
0.274
93.6% 1587
0.261
93 8% 1777
0 251
93.9% 1969
0.243
94.1% 2184
0.236
94.3% 2579
0.226
94.4% 2954
0 218
94.5% 3319
0.212
94 6% 3689
0.208
94.7% 4098
0.203
94.8% 4858
0.198
94.9% 5267
0.195
94.9% 5988
0.192
95.0% 6719
0.189
95.9% 1534
0.165
88.7% 427
0.S49
89.9% S33
0.485
90.9% 664
0.432
91.7% 839
0.386
92.3% 977
0.302
92.8% 1184
0.329
93.2% 1425
0.306
93.7% 1724
0.283
93.9% 1960
0.270
94 1% 2196
0.260
94.2% 2428
0.252
94 4% 2693
0.245
94.6% 3184
0.234
94.7% 3649
0.226
94.8%
0.220
94 9% 4S73
0.215
95.0% S082
0.211
9S. 1 %
5997 0.205
95.2% 6S41
0.202
95.2% 7403
0.198
9S. 2% 8308
0.196
96.1% 1899
0.171
All dere from Mellon Institute. University of Pittsburgh tests.
soo
89.3% 521
0.567
90.4% 650
0.502
91 4% 811
0 446
92.2% 1022
0.399
92.6% 1164
0.374
93.2% 1446
0.340
93.6% 1741
0.316
94.0% 2108
0.293
94.3% 2398
0.279
94.4% 2689
0.269
94.6% 2973
0.261
94.7% 3300
0.253
94.9% 3904
0.242
95.1% 4477
0.233
9S. 1 % 5035
0.228
95.2% 5602
0.223
95.3% 6228
0.218
95.4% 73S2
0.213
95.4% 800S
0.209
95.S% 9111
0.205
95.5% 10229 0.203
96.3% 2307
0.177
350
89.8% 625
0.586
90.9% 779
0.518
91.8% 972
0.461
92.6% 1227
0.412
93.0% 1398
0.387
93.5% 1737
0.352
93.9% 2093
0.327
94.3% 2535
0.303
94.5% 2880
0.289
94.7% 3231
0.278
94.9% 3S74
0.269
9S. 0% 3968
0.262
95.2% 4707
0 250
95.3% 5400
0.241
9S 4% 6076
0.236
95.5% 6749
0.230
95.5% 7505
0.226
9S. 6% 886S
0.220
95.7% 9678
0.216
9S. 8% 11018 0.212
95.8% 12378 0.209
96.5% 2787
0.183
Itlr
HEAT INSULATION DATA
BASE THERMAL TABLE
3" Thickness
EFFICIENCIES, HEAT SAVINGS AND UNIT HEAT LOSSES
Sovingt ere in B. T. U. per linear foot of pipe per hour. Unit losses ere in B. T. U. per square foot of pipe surface per hour per eF. temperature difference between pipe and surrounding air.
Pipe Size
TEMPERATURE DIFFERENCE *F. BETWEEN FIFE AND SURROUNOING AIR 100 150 200 230 300 330 400 450
I % Efficiency .. . 1 84.39c i 85.3%
W
{ Savings................ ] j Unit Loss............ ]
46 ' 0.388
78 0.406
i % Efficiency . .. ! 86.0%
86.8%
| Savings................
57 1
97
1 Unit Loss............ 1 0.341 1 0.357
! % Efficiency ... ! 87.3%
1"
' Savings................
| Unit Loss............
\1
0.30721
88.1% 120
0.31S
1%'
% Efficiency . ..
Savings................ Unit Loss............
88.69c 90
0.267
89 3% 1S2
0.280
V/z" 2"
% Efficiency ...
Savings................ Unit Loss............
% Efficiency . . .
Savings................ Unit Loss............
89.2% 103
0.250
90.0% 127
0.226
89.8% 172
0.262
90.6% 213
0.236
2Vz"
% Efficiency ... Savings................ Unit Loss............
90.7% 152
0.208
91.2%
2S6 0.218
% Efficiency . . .
91.3%
91.8%
3" Savings................ 184 309
Unit Loss............
0.192
0.201
3y2"
% Efficiency ... Savings................
Unit Loss............
91.6%
209 0.184
92.1%
351 0.192
4" *5e Efficiency . .. Savings................
91 9% 234
92 4% 394
Unit Loss............
0.176
0 184
41/2"
% Efficiency . . . Savings ............... Unit Loss............
92.1%
2S8 0.170
92.5% 433
0 178
% Efficiency . - .
92.3%
92 7%
5" Savings................
285
479
Unit Loss............
0 164
0.172
6" % Efficiency . . . Savings................
92.6% 337
93.0% 564
Unit Loss............
0.156
0.163
7" % Efficiency . . . Savings................
92.7% 386
93.2% 646
Unit Loss............
0.1S1
0. 1S7
8" % Efficiency . . . Savings................
92.9% 433
93.3% 725
Unit Loss............
0.146
0.153
% Efficiency . . .
93.0%
93.4%
9" Savings................
479
803
Unit Lot*............
0.142
0.149
10'
% Efficiency ... Savings................ Unit Loss............
93.2% 533
0.139
93.5% 893
0.146
12"
% Efficiency . .. Savings................
Unit Loss............
93.3% 627
0.135
93 7%
10S3 0.141
14"
% Efficiency ... Savings.................
Unit Loss............
93.4%
681 0.132
93.7% 1143
0.139
16'
% Efficiency ...
Savings................. Unit Loss............
93.4%
770 0.130
93.8% 1295
0.136
18"
% Efficiency ... Savings................. Unit Loss............
93.5%
865 0.127
93.9%
1455 0.133
Fit Vertical 3" Th'k
% Efficiency ...
Savings ................
Unit Loss............
94.9% 202
0.109
95.3%
343 0.114
86.4% 118
0.423
87.9% 149
0.372
89.0% 182
0 329
90.1% 230
0.292
90.6% 262
0.273
91.4% 324
0.246
91.9% 389
0.227
92.4% 470
0.210
92.7% 532
0 200
92.9% S96
0.192
93.1% 6S9
0.186
93.3% 729
0.179
93.6% 861
0.170
93.7% 982
0 164
93 9% 1104
0.1S9
94 0% 122S
0.1SS
94 1% 1357
0.152
94 2% 1600
0.147
94.2% 1740
0.145
94.3% 1972
0.142
94.4% 2218
0.139
95.6% 516
0.120
87.1% 163
0.441
88.4% 204
0.388
89.6% 253
0.343
90.6% 319
0.304
91.1% 363
0.284
91.8% 448
0.257
92 4% 539
0 237
92.8% 651
0.219
93.1% 738
0.209
93 4% 828
0 200
93 . S% 913
0.193
93.7% 1011
0 187
93 9% 1194
0.178
94.1% 1370
0 171
94.3% 1540
0 166
94 4% 1709
0.162
94.5% 1896
0.1S8
94.6% 2230
0.1S3
94.6% 2426
0.1S1
94.7% 2754
0.147
94.7% 3084
0.145
95.8% 716
0.125
87 8% 217
0 458
89.0% 270
0.403
90.2% 337
0.3S6
91.2% 425
0.316
91.6% 482
0 296
92.3% S98
0.267
92.8% 717
0.246
93.3% 867
0.227
93.5% 984
0.217
93.8% 1104
0.206
93.9% 1222
0 201
94.1% 13S4
0.194
94.3% 1S96
0.185
94.5% 1825
0.178
94 6% 20S4
0.173
94.7% 2282
0.168
94.8% 2S31
0.165
94 9% 2981
0.159
95.0% 3245
0.1S7
95.0% 3687
0.153
95.1% 4131
0.151
96.1% 951
0.130
All deta from Mailon Institute, University of Pittsburgh tests.
88.4% 279
0.476
89.6% 348
0 418
90.7% 432
0.370
91.6% S45
0.328
92.1% 621
0.307
92.7% 769
0.277
93.2% 924
0.2S5
93.7% 1118
0.236
93 9% 1270
0.225
94.1% 1421
0 216
94.3% 1S73
0.209
94.4% 1744
0.202
94.6% 20S9
0.192
94 8% 23S6
0.185
94.9% 2653
0.179
95.0% 2947
0.175
95.1% 3272
0.171
95.2% 3856
0.165
95.3% 4201
0.163
9S.4% 4775
0.159
95.4% 5354
0.157
96.3% 1227
0.135
89.0% 350
0 493
90 1% 436
0.434
91.2% 543
0.383
92.1% 686
0.340
92.5% 779
0.318
93.1% 969
0.287
93 6% 1164
0.265
94.0% 1407
0.245
94.2% 1598
0.234
94 4% 1790
0.224
94.6% 1983
0.216
94.7% 2199
0.209
94 9% 2598
0.199
95.1% 2975
0.191
95.2% 3342
0.186
95.3% 3716
0.181
95.4% 4127
0.177
95.5% 4893
0.172
95.5% 5305
0.169
95.6% 6033
0.16S
9S. 7% 6770
0.162
96.5% 1544
0.140
89 5% 431
0.511
90.6% 537
0.449
91.6% 669
0.397
92.5% 845
0.3S2
93.0% 984
0.330
93.5% 1193
0.298
93.9% 143S
0.274
94.3% 1736
0.254
94 5% 1973
0.242
94 7% 2211
0.232
94.9% 2444
0.224
95.0% 2712
0.217
95.2% 3206
0.206
95 4% 3674
0.198
95.5% 4140
0 193
95 6% 4604
0.188
95.6% 5116
0.184
95.8% 6037
0.178
95.8% 6585
0.17S
95.9% 74S4
0.171
95.9% 8367
0.168
96.7% 1910
0.145
500
90.0% 525
0.528
91.1% 655
0.465
92.0% 817
0.411
92.9% 1030
0.364
93 2% 1173
0 341
93 8% 1456
0.308
94 3% 1753
0.284
94.6% 2122
0.262
94.9% 2413
0.250
95 0% 2706
0.240
95.2% 29C2
0.232
95.3% 3321
0.224
95. $% 3929
0 213
9S.6% 4505
0.205
95.7% 5068
0.199
95.8% 5638
0.194
95.9% 6268
0.190
96 0% 7400
0.184
96.0% SOS 7
0.181
96.1% 9169
0.177
96.2% 10297 0.174
96.9% 2320
0.150
350
90.5% 630
0.545
91.5% 785
0.480
92.4% 979
0.4?4
93.2% 1235
0.376
93.6% 1407
0 352
94 1% 1749
0 318
94 s% 2107
0.293
94 9% 2552
0.271
9S 1% 2897
0 259
95 :% 3250
0 248
9S 4% 3596
0 239
95.5% 3992
0.232
9S. 8% 4736
0.220
95.9% 5432
0.212
96 0% 6114
0 206
96.1% 6790
0.201
96.1% 7SS2
0.196
96.2%. 8920
0.190
96 3% 9737
0.187
96 3% 11085 0.183
96 4% 12453 0. 180
97.0% 2802
0.155
c
HEAT TRANSMISSION FROM SURFACES
BULLETIN 102.A
E S T. 18 7 3
\
THE PHILIP CAREY MFG. COMPANY
General Officer -- LOCKLAND, CINCINNATI, OHIO Branchas la AH Principal Chit*
HEAT TRANSMISSION
FROM SURFACES
Bulletin No* 102 A
THE PHILIP CAREY MFG. COMPANY CINCINNATI, OHIO
R. H. Heilman's paper "Surface Heat Transmission,''Trans. Am. Soc. Mech. Engrs., Fuels Steam Power, 51, 257 (1929), gives a sound basis for determining losses, savings to be made by the use of heat insulation, and the per cent efficiency of such insulation.
Many and conflicting claims of efficiency have been made for various commercial heat insulations. It is obvious that the efficiencies and savings cannot be compared unless the same heat losses from the bare surfaces are used as a basis. As mentioned in the paper above, several types of commercial shapes, such as pipes and flat plates, were tested.
From the results of those tests a formula was developed for the transfer by free convection, and emissivity values were determined for various surfaces for use in the Stefan-Boltzmann radiation formula. The separation of heat transmission from a surface to the sur rounding air into its two components--radi ation and convection--greatly extends the range of usefulness of former tests on bare and insulated surfaces. By means of these two formulae and the emissivity of various surfaces, one is able to calculate the rate of heat transfer under still air conditions for practically any shape or type of surface and for any temperatures ordinarily met with in engineering practice:
The formulae are as follows:
qc=C(')J ( --)-181 At1'** Ls 1 aog.
--10
<^r=! 7.4 x 10 x e (Tx4 -- T24)
where
qc=heat transfer by free convection in Btu per sq. ft. per hr.
C=a constant depending upon the shape of the surface.
(C--1.016 for horizontal cylinders,=1.235 for long vertical cylinders, = 1.394 for vertical plates,=1.79 for horizontal plates facing upward, and=0.89 for horizontal plates facing downward. The constants for the horizontal plates facing up ward and facing downward are reversed when the plates are cooler than the surrounding air.)
D=cylinder diameter in inches or height of vertical plane in inches. (The effect of diameter or height becomes constant at a value of approximately 24 inches.)
T ai>.=460 plus the average of cylinder or plate surface and surrounding air temperature in deg. Fahr.
2
At=temperature difference (deg. Fahr.) between surface and air.
q^heat transfer by radiation in Btu per sq. ft. per hr.
^=emissivity of surface. (A value of 0.9 can be assumed as the emissivity of most industrial surfaces, such as brick, stone, glass, canvas, asphalt roofing and various colored flat paints at temperatures below 400 deg. Fahr. For highly polished met als "e" may be as low as 0.02.)
Ti=temperature of the hotter sur face, deg. Fahr.+460.
T2=temperature of surrounding ob jects, deg. Fahr.+460.
The bare pipe loss curves, the bare pipe loss tables, the surface loss curves for various outside diameters and the surface heat trans mission from flat bare steel surfaces, con tained in this bulletin, were all calculated with the above formula for free convection and radiation. The calculations were all based on an air temperature of 80 deg. Fahr. and with the surfaces at higher temperatures than the surrounding atmosphere.
Effect of Wind
The formula given above for free con vection cannot be used for conditions where extraneous air currents are blowing over the surfaces. In this case the heat transfer takes place by forced convection and radiation. The forced convection for large bare plane surfaces greater than two feet on a side, can be obtained from the formula
q/c=1.+0.225V.
where
qyc=heat transfer by forced convec tion in Btu per hr. per sq. ft. per deg. Fahr. temp. diff.
V=air velocity in feet per sec.
This formula is an approximate average of formula proposed by various investigators. The heat transmission curves shown on page 10 for large bare surfaces with various wind velocities were calculated from the above formula and the radiation formula. In this case an air temperature of 70 deg. Fahr. was assumed.
The data available on forced convection at present are not sufficient to enable one to differentiate to any degree of accuracy be tween the losses from plane surfaces in the various positions.
Considerable experimental work has been done on forced convection from wires and cylinders. The forced convection for air flowing at right angles to various sized single horizontal cylinders can be obtained from Reiher's equation which is as follows:
k ,DV/3}.56 w-35 n(
where
qyc=surface conductance, Btu/sq. ft./hr./F.
k=thermal conductivity of air Btu/ft./hr./F.
D=outside diameter of pipe, ft.
V=air velocity, ft./hr.
^^Jensity of air, lb./ft.3
viscosity of air, lb./ft.--hr.
The heat transmission curves shown on page 9 for various diameter bare steel pipes with various wind velocities were calculated from the above formula and the radiation formula. In this case also, an air tempera ture of 70 F. was assumed.
Losses F rom H o riz o n ta l B are Steel Steam Pipes
F ro m 100 L in e a r F eel o f P ipe per M o n th o f 30 D a y * W ith S team in P ipes 24 hours per D a y. C oal a t $7.00 per T o n o f 2000 Lbs.
792 7.44
191
9 per
< : JH. `wa'i/wj P*wn/ug
C wi
.
* &!H
id panoj
mS*iNrNWimsr>*eiNmMrN>A> -- q^N-#'NOT#'N^-NT-<e
-- -- -- -- -- -- IN IN
^Sm'* -- Pmi*ain -- mN^f>-iN0 - m in in N- in i*Ami"*<',\r**riAiNiNiN^
> IN :
*^na
"Cwa *Jo 7aooj
*b0 *Si1 . i j^
5 3 1
taun nag iTMo
spunoj
8? "n*ona
s J5 - I
s
iroun/tug P0
spunoj
noa
lAIiNAINOfrNm N-- N-- NlAC'meiT-- i'NC--NV-- eiCff' TNWiXe1'' - iX in u*s -- eNmmiN----iN--m--^f'---INiNINVI'NrNiNNmr'w^^'
-- --
-
m --
m -
-- m --
<Nm^ -- in in -- f*
Nm
m--
i--n --
imn
o^
N (S W (I ^ US lA
N in V in
-- n
in CO
'T
n--
N iA IN C -- ANNe^-A-- A^lCiAANAeee-cN>lAANV^
o n-- jl--t--AS-- O--NN>ANNC-- '(IAA--^^IAA--lAN
mm^ 8 8 U"\ m
v e IA l>i <Q
^ r**. AN IN
tOlAiA^W-N<t^AttNNO AeN3NN-'i--A'AiAjlAeeNtOlA--m-6-S^AN-IN
'-NAi(fi(*il*'T1'iA^N#^d-l*!t
-- -- -- ia r*. Nm ImN ^fAk f N IA V lA N
S_
IA
IA
N
lA N
^
r*.
^
N
A
>
IA N
in
4--
A
i--n
mieAne*
IN IN IN
- N IN IA N N -' lA
- - (N IN
._ OV A IA
IA
,fl|./,fl!a`i./Mi
iwon/^a
PD spunoj
*n "Tta
i^n/^a
PD spano^
1 "iia
,jH/*}j!a `do /*<d
i*un/n*8
PD cpuno^
"na
i~n/n4a
1*0 tpunoj
wnoQ
s IN fN
IN 5 IN fA -- -- AN
-- IN -- - an IN
IN X fA e r* IN
n- (A r
o
IN V
-- -- to s AM N S A
iA e
fA
8 IN
T
2
r^s
IN
?
e
IN
ftAA es
fSs lA <N
O<N'
<PNA
*r IN
5
$
rs fN
tn
<x *
m IN
ts IN
m I9N
fA
m IN
IN
mr
X m
m
X
NMA
X
V
o
PA
SIN
s
n
--
ia ia
* m
(IAA_ fIf|Nt.-ma0# NV9S>NOrNVAOrAAOiAAe>jl`AATiA4NlAIAAlA.N--
' -- -- IN IN` IN` m` ` ttri<e4Kfl9'9'N
_
A --A
A^A imIIAA -^--INlpOIN l--Nm. mm. m. inn.*---
--
-- NIAtANN^ -- IN ^ IN
o--
t IN Ap*. ^
tIAtNC--N^^NNN-Pt#N
V-- r-- oIN ItN eIN
m*
^CA^ilON' -- IA-- N*d
AIAVAAliN0<>
l^f**\ --I--N I<Nn 1*1
^IN -- N V IN IA Nn. --fOm N IiNn IAin tA^ A-- a-mN--Ai/a AilAIAIAVAAdNNdd^N
T-5OI'>TAAO8KSTAANifAlNlNNON9NieAAiAIeA9-A'fdl-tNIrA'-NIAAtAiiCNe-NmAN#INT
-- -- -- -- -- -- ININ
<rAYOONN -- NlAe^N
tN>0 -- ^ IN -- mININinin
^m -- -- VVANS9>
m <A AN A IN
?Ml I(N.
-- -- - fsj IN IN m PA V TAIAN9
699
IN o
$
PfAA O'
l*k
IN oIN
IN
As o(A
m m
N IN N IA IA
IN ^ ^ S A-- A(*l NN IAN 8 In SO IN IAN
fN fN -- i*i rN -- mm -- m in -- AN IN rNiNiNmiN -- -- m -- mV -- mV............................................
&n f
fill 6'
Ocl!
r**"n/na
1*0
*Punod
*n "na
$8 UA
AN
S5 -- in m
NANNO-IANfN
8 -- t66ttiaia -- Jh -- iA IN m -- -- IN m IN IN -- iNiNiNiNmmVVknViN -- 'emmiNiN -- m mm-- A-- --BiON-- i--NNeftNB2cNN2OmsNmO^A^cmA<mIASArN>n
IN IN IN AN
m in in in m -- n m kX IN -- m^ -- m
-- -- -- -- IN in in Sn
*!S **M
eNiANoNirc
MV
i^
-`
i*
*
_S*
e
3 -z
e
8 >> e
-- e -2
vv
22
C r.f
*2 o a
B
o
& e2
8& N Ld
e9
*j
21 i I
c I 13
J " "5 *"
S
i m
0%-
8
0 c.
1 8
u.
i
,
t>
s
>
S
m
'S - <
^s
MO
l
a CL
CO S
r
otc
cn
u
zU- H j
o
o Oz
in _1 O'
in uj tig
- > ccr
A "Se
(0
z
<
f
>
gd
Q UJ
tz <0kt
h-
L-OiOu
sl?
Ui
X CD
o
l: o
cJ X -y
CL
t
or (0
CC u
CL
cc X
tO
X Ui
a.
=J
to
z'
o
<n
co
f
cO z < X h*
ui
X
oa
(0 1/1 *
ou -* Q_
uJ
st:
>
r>
h-
0
o
y
ou
<r
sT-
Carey Heat Insulating Materials
High Temperature Surfaces (1000F. to 2500 F.)
Carey Hi-Temp No. 19--An efficient insu lator consisting essentially of a mixture of diatomaceous earth and asbestos fibre bonded and molded into commercial size blocks. This material is designed to give maximum efficiency with structural in tegrity in the temperature range from 1500 F to 1900 F--for use on ovens, regenerators, and kilns in this tempera ture range.
Super Heated Surfaces (500 F, to 1600 F.)
Carey Alltemp--Produced from a formula tion of expanded silicas and asbestos fibre. Available in sectional, tri-sectional, seg mental and block forms. ALLTEMP is recommended for insulating high temper ature piping and surfaces such as breech ing, boiler walls, ovens, stills and similar surfaces. It is an ideal insulator for irregular surfaces due to its workability and ease of application. Its exceptionally low shrinkage factor, plus low coefficient of conductivity assures outstanding eco nomical performance when used as a single material or in combination with Carey Super Light 85% Magnesia.
Alltemp is water resistant and offers an excellent surface for cements. Now ac cepted and being used by principal boiler manufacturers. Engineering contractors, and industry.
Carey Mineral Wool Blankets--(for use up to 1200 F.) A high-quality mineral wool felted to a density of approximately 12 lbs. per cubic foot, and encased between various types of metal fabrics. Furnished in large blankets or sheets 2 ft. wide x standard lengths of 4 ft. or 8 ft., or can be supplied to special lengths, and in thicknesses 1 in. to 6 in. inclusive. These blankets have high thermal efficiency and relatively low cost. They are particularly designed for use in oven walls or on other areas where large-size insulating units are wanted and where mechanical strength or smooth finish is not required.
Medium and High Temperature Surfaces (200 F. to 600 F.)
Carey Super Light 85% Magnesia--is pre
cision molded from a mixture of 85% basic Carbonate of Magnesia and approxi mately 15% asbestos fibre. Super Light has uniform, accurate dimensions--light density and low conductivity "K Factor." It has good strength, low shrinkage and excellent water resistance. Few materials have been so thoroughly tested and found to offer the long efficiency of performance with the economy of application found in Super Light.
Carey Asbestos Sponge--For temperatures up to 700 F. constructed of a series of laminated asbestos felts, averaging 30 to 35 layers per inch of thickness. Is recom mended for use on vibrating lines and on installations requiring a structurally tough insulation. Is available in large semicylindrical sections, blocks and sheets.
Low and Medium Pressure Steam Sur faces (100 F. to 300 F.)
Careycel--Constructed of many layers of "cellized" asbestos sheets. Unusually low thermal conductivity. Furnished in pipe covering sections, sheets and blocks.
Carey Air Cell--Course corrugated asbestos structure having four plies of corruga tions per inch of thickness.
Carey Excel--A medium corrugated asbestos structure having six plies of corrugations per inch of thickness.
Cold Water Pipes
Carey Impervo--Comprised from layers of insulating felt cemented together with asphalt saturated organic felts applied to both inner and outer surfaces. Used for insulating chilled and ice water lines to keep water cold and prevent sweating. Proper sealing by use of a suitable vapor barrier is recommended to prevent infil tration of water vapor through the barrier into the insulation causing condensation.
Carey Perfecto--Made up of laminations of insulating felt with waterproof felt liner and used to protect against freezing and sweating of cold water pipes.
Carey Protecio--Consists of an inner layer of hair felt reinforced by an outer layer of insulating felt and designed to reduce danger of freezing of exposed water pipes.
11
Pipe Size In.
8
10
12
14
16
18
Flat
COMBINATION COVERING FOR 700 F.
* Indicates Recommended Combinations
INNER LAYER CAREY AUTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
1% 1*%
1% v%
1% IH *1H 1H m VA * IH 1H 1H IH *1M 1H 1H
*1H IH 1H
Outer Layer Thickness inches
2% 2H 3%
1H
2
2H
3
IH
2
2H
3 IH 2
m 3
IH 2
2H 3
IH ,2
2H 3
IH 2
2H 3
Temp. F. at inner Magnesia Surface
441 479 504 515 442 474 500 519 448 479 501 520 468 494 518 540 470 496 520 543 472 499 522 545 482 517 541 560
Canvas Temp. F. with Air at 80 F.
125 118 113 109 128 121 114 111 128 122 116 113 131 124 119 114 132 125 120 116 133 126 121 117 131 125 119 115
B. T. U. Loss
Per Lin. Ft. Per Hr.
Covered Pipe
Bare Pipe
286 8,100
245 8,100
223 8,100
205 8,100
341 10,000
301 10,000
268 10,000
241 10,000
384 11,800
339 11,800
305 11,800
277 11,800
426 12,850
384 12,850
341 12,850
300 12,850
477 14,650
419 14,650
377 14,650
348 14,650
518 16,420
457 16,420
415 16,420
377 16,420
91.0 3,870
78.1 3,870
67.5 3,870
59.0 3,870
Percent Eff. %
96.4 96.9 97.2 97.4 96.6 97.0 97.3 97.5 96.7 97.1 97.4 ' 97.6 96.7 97.0 97.3 97.6 96.7 97.1 97,4 97.6 96.8 97.2 97.5 97.7 97,6 98.0 98.3 98.5
1s1
P*ge 6
Pipe Size In*
8
10
12
14
1A
COMBINATION COVERING FOR 800 F
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
1!% * 1%
1J% 2% 2%
*n%
2% 2% 2% 119% llfl% *1% 2% . 2% 2% 2% IK IK 2 *2 2 2 IK IK 2 *2 2 2
Outer Layer Thickness Inches
v% 2% 2H li%
2% IK 2
2K IK 2
2K IK 2
2K IK 2
2K 3
IK 2
IK 2
2K 3
IK 2
IK 2
2K 3
Temp. F. at Inner Magnesia Surface
507 546 577 461 496 504 540 570 452 494 520 511 548 574 467 499 532 555 535 564 482 517 551 571 537 568 485 520 554 575
Canvas Temp. F. with Air at 80 F.
133 125 120 127 121 136 129 120 129 122 118 137 129 123 130 125 119 115 140 132 133 126 121 116 141 133 134 127 122 117
B. T. U. Loss
Per Lin. Ft. Per Hr.
Covered Pipe
Bare Pipe
341 11*080
295 11*080
270 11,080
309 11.080
282 11.080
412 13,700
363 13,700
323 13,700
368 13,700
326 13,700
304 13,700
' 464
16,200
404 16,200
364 16,200
417 16,200
384 16,200
344 16.200
317 16,200
513 17,700
462 17,700
465 17,700
421 17.700
374 17,700
344 17,700
578 20,100
511 20,100
519 20,100
452 20,100
410 20,100
364 20,100
Percent Eff.
%
96.9 97.3 97.5 97.2 97.4 96.9 97.3 97.6 97.3 97.6 97.8 97.1 97.5 97.7 97.4 97.6 97.9 98.0 97.1 97.4 97.4 97.6 97.9 98.0 97.1 97.5 97.4 97.7 97.9 98.2
Psge 8
Pipe Size In.
18
Flat
COMBINATION COVERING FOR BOO F.
* indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness inches
1M ` IH
2 *2
2 2
1M 2 *2 2
2M 2M
2H 2H
Outer Layer Thickness Inches
1M 2
1H 2
2H
3
W VA 2
2H
1H 2
2H
3
Temp. F. at Inner Magnesia Surface
539 572 490 524 559 580 550 504 549 581 466 510 547 570
Canvas Temp. F. with Air at 80 F.
142 134 135 128 123 118 140 135 129 123 130 124
120
117
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
632 22,600
551 22,600
570 22,600
495 22,600
453 22,600
400 22,600
110 5,000
96.9 5,000
84.1 5,000
74.3 5,000
86.7 5,000
76.0 5,000
68.0 5,000
61.5 5,000
Percent Eff. %
97.2 97.6 97.5 97.8 98.0 98.2 97.8 98.0 98.3 98.5 98.3 98.5 98.6 98.8
Pace 9
Pipe Size in.
Vi % 1 V/4 VA 2
3
4
S
COMBINATION COVERING FOR 900 F
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
2*6 ls% 2H m 2% 1*% *H% i*% i'% 1% m
2*6 2*6 2*6 2*J> *1*6
1*6 2*6 2*6 2% 2*6 1% 11% 2% *2% 2% 2*6 2% 2*6
Outer Layer Thickness inches
None None None None None
1% iJ% 2% 2*6 m 2% 2% 1J% 2*.
3% 1% 2% l`% 2% 21*6 m 11% 2% 1*% 2% 21% 2% 2i%
3%
Temp. F. at Inner Magnesia Surface
438 492 531 567 516 558 589 458 500 532 560 534 576 474 515 554 577 550 591 492 545 575 480 515 542
Canvas Temp. F. with Air at 80 F.
136 142 141 149 141 138 127 120 115 132 123 118 125 118 114 110 134 125 127 121 115 111 136 128 129 122 116 118 114 110
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
147 1.560
169 1.930
182 2.400
216 3.010
208 3,430
201 4,240
179 4,240
164 4,240
162 4.240
222 6,170
200 6,170
184 6,170
208 6,170
190 6,170
178 6,170
150 6,170
260 7,860
231 7,860
239 7,860
220 7,860
198 7,860
187 7,860
297 9,660
268 9,660
273 9,660
243 9,o60
224 9,660
235 9,660
217 9,660
203 9,660
'
Percent Eff. %
90.5 91.2 92.4 92.8 93.9 95.2 95.7 96.1 96.2 96.4 96.7 97.0 96.6 96.9 97.1 97.5 96.7 97.0 96.9 97.2 97.5 97.6 96.9 97.2 97.1 97.4 97.6 97.5 97.7 97.9
Pipe Size In.
6
8
10
12
COMBINATION COVERING FOR 900 F.
* indicates Recommended Combinations
INNER LAYER CAREY AUTEMP, OUTER LAYER SUPER-LIGHT <5% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness inches
m 2&
2%
2% 2% 1% 2Ht *2% 2% 2% 1% 2% *2% 2$&
2% 2% 1?6
2%
2% 2^
3*6 3% 3 3%
Outer layer Thickness Inches
l1^ l1^ 2%
1% 2%
3*6
1*% 1%
2*6
2 2H 1H
2
2M 2 2^
1H 2 1H
2
1H
2
2H
3
Temp. F. at inner Magnesia Surface
364 503 S46 453 498 557 572 517 560 491 525 566 508 556 587 509 540 574 523 560 475 519 435 469 513 540
Canvas Temp. F. with Air at 80 F.
139 131 123 126
120
111
140 134 127
122
118 144 136 129 124 125
120
146 138 132 133 126 126
122
118 115
B. T. U. Less
Per Lin. Ft. Per Hr.
Covered Pipe
338
Bare Pip*
11.460
305 11,460
274 11,460
286 11,460
258 11,460
225 11,460
397 14,800
366 14,800
330 14,800
311 14,800
289 14,800
484 18,300
437 18,300
388 18400
354 18400
365 18400
340 18400
544 21,600
498 21,600
457 21,600
460 21,600
420 21,600
420 21,600
394 21,600
360 21,600
333 21,600
Percent Eff.
%
97.0 974 97.6 974 97.7 98.0 97.3 974 97.7 97.9 98.0 97.3 97.6 97.8 98.0 98.0 98.1 974 97.7 97.9 97.9 98.0 98.0 984 98.3 98.4
Pege 11
COMBINATION COVERING FOR 900s F.
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 5% MAGNESIA SO9 P. Ambient Air Temperature
Pipe Size In.
Inner
Layer Thickness
Inches
2 2 *2M m 14 3 3 3 3 2 *2H VA 16 3 3 3 3 2
*2M
2M
18 3 3 3 3 2
Flat
i
2H
3 3 3
Outer Layer Thickness Inches
lH 2
lH 2
VA 2
2A 3
1H W
2
1A 2
2A 3
w m 2
w 2
2A 3
m 1M 2
1H
2 2H
Temp. F. at Inner Magnesia Surface
543 583 489 530 446 492 529 555 547 492 535 450 496 534 560 552 496 541 455 500 539 565 56* 521 572 486 529 568
Canvas Temp. 4F. with Air at 80 F.
141 134 135 128 130 124 121 117 143 136 129 131 125 122 118 144 137 131 132 126 123 119 142 135 131 132 127 121
B. T. U. loss Per Lin. Ft.
Per Hr.
Covered Pip*
Bar* Pip*
550 23.600
495 23.600
498 23.600
458 23,600
469 23,600
425 23,600
392 23,600
352 23,600
607 26,800
557 26,800
490 26,800
582 26,800
452 26,800
535 26,800
402 26,800
684 30,300
603 30300
552 30,300
566 30,300
495 30300
486 30300
429 30300
115 6,650
102.3
6,650
90.3 6,650
92.2 6,650
82.6 6,650
74.4 6,650
Percent Eff.
%
97.7 97.9 97.9 98.1 98.0 983 98.4 98.5 97.7 97.9 983 97.8 98.3 98.0 98.5 97.7 98.0 983 98.1 98.4 98.4 98.6 98.3 98.4 98.6 98.6 98.7 98.9
Pip 12
Pipe Size In.
% % 1 V/a VA 2
3
4
5
6
COMBINATION COVERING FOR 1000F.
* indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
2*6
l3Xt m
2*6
m 2H
1*6 *2*6
2*6
2% 2%
*2*6 2*6 2*6 2*6 2^
*2*fi 2*6 2*6 3*6 2%
*2% 2%
3Xz
3& 3`*6
Outer Layer Thickness Inches
None None None None None 1*6
1%
1
1* 1* 1 2&
1%
2&
1% 2^ 1% 2*6 1% 1% 2*2 2%
l1^ l1^ v% 2Hi
2% m
Temp. F. at Inner Magnesia Surface
485 547 442 473 574 509 560 447 502 530 574 480 535 544 494 536 576 449 559 503 555 458 505 400
Canvas Temp. F. with Air at 80 F.
143 150 149 157 149 145 134 132 126 139 131 123 125 119 133 126 127 120 136 129 124 119 124 137 132 126 127 122 123
B. T. U. Less
Per Lin. Ft. Per Hr.
Covered Pipe
Bare Pipe
170 2,030
195 2,510
210 3,120
250 3,910
240 4,450
231 5,520
205 5,520
204 5,520
195 5,520
261 8,050
242 8,050
218 8,050
230 8,050
210 8,050
276 10,280
253 10,280
259 10,280
235 10,280
320 12,650
292 12,650
272 12,650
250 12,650
276 12,650
352 15,000
332 15,000
300 15,000
312 15,000
291 15,000
298 15,000
Percent EfF.
%
91.6 92.2 93.2 93.6 94.6 95.8 96.3 96.3 96.5 96.7 97.0 97.2 97.1 97.3 97.3 97.5 97.4 97.7 97.4 97.7 97.8 98.0 97.8 97.6 97.7 98.0 97.9 98.0 98.0
Page 13
COMBINATION COVERING FOR 1000 F.
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA SO4 F. Ambient Air Temperature
Pipe Size In*
*
Inner Layer Thickness Inches
2%
2%
2%
m
10
12
14
16 1 i
2% *2%
3%
3$6 3>%
2%
2%
*3%
3% 3% 3i%
31%
2M *3
3
3M 3M
4
2Y2
*3
3
3H
m
4
Outer Layer Thiekness Inches
1!%
IX
2
IX
2
IX
2 IX 2 IX
IX
IX
ix 2 2X ix 2 ix IX 2 ix 2 vx
IX
IX
2 ix 2 ix
Temp. F. at Inner Magnesia Surface
574 495 543 450 507 565 567 463 517 431 580 527 481 520 570 442 495 540 495 545 459 510 432 543 500 550 463 514 436
Canvas Temp. F. with Air at 80 F.
141 135 129 130 124 144 131 132 126 127 146 140 132 128 124 130 125 142 136 130 132 127 129 144 137 131 133 128 129
B. T. U. Loss Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
424 19.400
397 19.400
363 19,400
372 19,400
338 19,400
506 24,000
422 24,000
442 24,000
402 24,000
413 24,000
580 28,400
535 28,400
491 28,400
457 28,400
420 28,400
467 28,400
434 28,400
582 31,000
544 31,000
495 31,000
505 31,000
470 31,000
480 31,000
657 35,400
586 35,400
528 35,400
557 35,400
515 35,400
528 35,400
Percent Eff.
%
97.8 97.9 98.1 98.0 98.2 97.8 98.2 98.1 98.3 98.2 97.9 98.1 98.3 98.4 98.5 98.4 98.5 98.1 98.2 98.4 98.4 98.5 98.4 98.1 98.3 98.5 98.4 98.5 98.5
o 14
Pipe Size In*
18
Flat
COMBINATION COVERING FOR 1000 F,
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
*3 3
sx
4
2H
*3
m
4
Outer Layer Thickness Inches
1*4
W 2
IX 2
IX ix ix IX
2
IX
Temp. F. at Inner Magnesia Surface
546 500 555 467
518 440 578 537 508 560 475
Canvas Temp. #F. with Air at 80 F.
146 138 132 134
129 130 142
139 134 130 130
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
726 39,800
641 39,800
585 39,800
608 39,800
552 39,800
575 39,800
119 8,700
108 8,700
97.5
8,700
87.5
8,700
90.1
8,700
Percent Eff. %
98.2 98.4 98.5 98.5 98.6 98.5 98.6 98.7 98.9 99.0 99.0
V
Page 15
COMBINATION COVERING FOR 1100F.
* indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Pip* Six*
In.
Inner Layer Thiekness
Inches
'A
y*
i VA VA 2
3
4
5
* i
i
2*6 1*%
2X m m 2 H
2H
2Vs 2H 2Vs *2%
2% 2% 3*6 3*
- 3*6
2*6 *2%
2*6 3% 3% 3*2 2*6 2*6 *3*6 3*6 3*6 2% 3% 3*6 3^*6 3!*6
Outer Layer Thickness Inches
None None None None None
ix
2*6
l*%
2*6 21*6 11*6 1*% 2*6
11*6
2% 21*6 1% ii*6 2% 11% 256 2!% 1% 2% 11% 2% 2$* li% 11% 2% 1H 2
Temp. F. at Inner Magnesia Surface
...
517 571 475 518 557 560 498 553 453 516 547 586 529 585 479 528 562 540 592 490 540 577 554 506 556 443 497
Canvas Temp. F. with Air at 80 F.
150 158 156 165 156 133 123 125 120 115 137 131 124 126 120 115 140 132 126 126 121 118 135 128 130 124 121 138 132 127 128 123
B. T. U. loss Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
193 2,580
222 3,200
238 3,980
283 5,000
273 5,700
223 7,090
206 7,090
210 7,090
199 7,090
187 7,090
276 10,330
262 10330
241 10330
247 10,330
224 10330
216 10,330
313 13310
295 13310
272 13310
279 13310
259 13310
246 13310
336 16350
310 16350
317 16350
295 16350
276 16350
378 19300
356 19300
329 19300
340 19300
315 19300
Percent Eff.
%
92.5 93.0 94.0 94.3 953 96.8 97.1 97.0 973 97.4 97.3 97.5 97.6 97.6 97.8 97.9 97.6 97.7 97.9 97.8 98.0 98.1 97.9 98.0 98.0 983 983 98.0 98.1 983 983 983
Psge 16
Pipe Size In.
8
10
13
14
16
18
COMBINATION COVERING FOR 1100F.
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness inches
2%
3X *3K
3y%
2*% 3% *356 3i% 3% 3>%
2% 356 356
*3% 31% 2H 3
3H 4 4 3 *3M 354 4 4 3 *3H 354 4 4
Outer Layer Thickness inches
1M 134 2
134 2
134 134 2
1H 2
234 134 134 2
134 2
134 134 134 2
134 2
134 134 2
134 2
134 134 2
134 2
Temp. F. at Inner
Magnesia Surface
544 498 557 466 517 569 508 565 470 535 580 580 527 571 488 545 592 544 503 550 476 522 550 509 555 482 528 555 514 562 488 535
Canvas Temp. F. with Air at 80* F.
141 135 129 130 125 144 138 132 133 128 123 147 139 134 135 130 150 143 138 136 134 129 144 139 137 135 130 145 140 138 136 131
B. T. L 1. Less Per L n. Ft.
Per Hr.
Covered Pipe
Bare Pipe
453 25,000
424 25,000
388 25,000
397 25,000
372 25,000
532 30,900
506 30,900
461 30,900
476 30,900
430 30,900
402 30,900
610 36,600
569 36,600
521 36,600
533 36,600
492 36,600
667 40,000
619 40,000
580 40,000
555 40,000
540 40,000
513 40,000
678 45,500
628 45,500
624 45,500
586 45,500
549 45,500
740 51,300
693 51,300
684 51,300
660 51,300
604 51300
Percent Eff.
%
98.1 98.3 98.4 98.4 98.5 98.2 983 983 98.4 98.6 98.7 98.3 98.4 98.6 98.5 98.6 98.3 98.4 98.5 98.6 98.6 98.7 98.5 98.6 98.6 98.7 98.8 98.5 98.6 98.6 98.7 98.8
Pipe Size In.
Flat
COMBINATION COVERING FOR 1100F.
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
3
4
4
4H m
Outer Layer Thickness Inches
W m m 2
ih
2
Temp. F. at Inner
Magnesia Surface
590 547 516
578 487 541
Canvas Temp. F. with Air at 80 F.
145 139 135 130 131 128
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
123 11,180
111 11,180
101 11,180
92.6 11,180
94.4 11,180
87.1 11,180
Percent Eff. %
98.9 99.0 99.1 99.2 99.1 99.2
v
D.** tp
Pipe Size In.
'/a %
1
VA VA
3
4
*
6
COMBINATION COVERING FOR 1200F.
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
2% 1*% 2H 1*% 2%
* 2y% 2% 2% 3X
*2% 3X6 3% 3% 3i% 2%
*3% 3% 3i%
*3% 3% 4% ' 4% 3%
*3i% 31% 4M 4M
Outer Layer Thickness Inches
None None None None None
M
li% 2% 1*% 1*% 11%
2% li% 2% 11% 11% 2% li% 2% li% 2% 1M 2 li%
1H 2
IH 2
Temp. F. at Inner
Magnesia Surface
563 516 569 463 544 493 562 458 503 580 523 573 479 526 530 547 426 481 555 486 540 455 505
Canvas Temp. F. with Air at 80 F.
157 166 164 174 164 138 131 125 126 136 130 124 125 121 137 131 126 128 122 135 125 126 122 138 133 128 130 124
B. T. U. Loss Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
216 3.240
248 4.040
266 5,000 317 6,300
305 7.200
254 8,920
238 8,920
224 8,920
228 8320
296 13,050
281 13,050
257 13,050
263 13,050
250 13,050
333 16,730
315 16,730
293 16,730
300 16,730
283 16,730
360 20,600
317 20,600
330 20,600
311 20,600
400 24,400
383 24,400
359 24,400
362 24,400
343 24,400
Percent Eff.
%
93.3 93.8 94.7 94.9 95.7 97.1 97.3 97.5 97.4 97.7 97.8 98.0 97.9 98.0 98.0 98.1 98.2 98.2 98.3 98.2 98.4 98.4 98.5 98.3 98.4 99.1 98.5 98.6
Page 19
Pipe Size In.
8
10
12
14
16
18
COMBINATION COVERING FOR 1200 F,
* Indkotes Recommended Combination*
INNER LAYER CAREY AllTEMP, OUTER LAYER SUPER-UGHT 15% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
3X *3%
3H
4% 3% 3*56 3% 4% 4%
3%
*3% 3i% 4K 4H 3
4 4 4^ *3M 4 4 4K 4H *3^ 4 4 4H
m
Outer Layer Thickness inches
ix IX 2
IX 2
ix IX 2
IX 2
IX IX 2
IX 2
ix ix ix 2
ix ix ix 2
IX 2
IX ix 2
IX 2
Temp. F. at Inner
Magnesia Surface
547 506 566 457 514 554 509 581 488 531 574 534 594 487 552 594 545 520 565 475 551 525 571 481 547 555 529 576 486 552
Canvas Temp. F. with Air at 80 F.
141 136 130 132 127 145 140 133 134 130 146 141 135 137 132 149 144 139 134 136 146 140 135 137 132 147 141 136 138 133
8. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
476 31.600
451 31,600
417 31,600
433 31,600
406 31,600
571 39,100
540 39,100
490 39,100
500 39,100
475 39,100
634 46,400
600 46,400
550 46,400
577 46,400
527 46,400
696 50,700
656 50,700
619 50,700
579 50,700
586 50,700
724 57,700
670 57,700
615 57,700
645 57,700
600 57,700
787 64,900
722 64,900
679 64,900
712 64,900
650 64,900
Percent Eff.
%
98.4 98.5 98.6 98.6 98.7 98.5 98.6 98.7 98.7 98.8 98.6 98.7 98.8 98.7 98.8 98.6 98.7 98.7 98.8 98.8 98.7 98.8 98.9 98.8 99.0 98.8 98.9 99.0 98.9 99.0
Pe 20
Pipe Size In.
Flat
COMBINATION COVERING FOR 1200 F,
* Indicates Recommended Combinations
INNER LAYER CAREY ALLTEMP, OUTER LAYER SUPER-LIGHT 85% MAGNESIA 80 F. Ambient Air Temperature
Inner Layer Thickness Inches
3M *4
5 5
Outer Layer Thickness Inches
1H
IH
1M
1H 2
Temp. F.
at Inner Magnesia
Surface
599 565 535
515 580
Canvas Temp. F. with Air at 80 F.
146 142 138 134
131
B. T. U. Less Per Lin. Ft.
Per Hr.
Covered Pipe
Bare Pipe
127 14,110
116 14,110
107 14,110
99 14,110
92 14,110
Percent Eff.' %
99.1 99.2 99.2 99.3 99.3
Page 21
DOUBLE LAYER ALLTEMP COVERING For 1300 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Sixe In.
v%
S/4
1
Thickness Inches
Inner Layer
Outer Layer
3-11/32
None
3-1/4
None
3-5/32
None
. 1V4 ' 1%
2
0s0.
2-31/32 3-11/32
2-1/8
None None 1-1/2 2-1/32
*2-1/16
3
2-9/16
2-1/32 2-1/32
2-9/16
4
2-9/16
2-5/32 2-21/32
2-9/16
5
2-9/16
2-3/32 2-19/32
- 2-17/32
6
2-17/32
2-3/32 2-5/8
2-11/16
8
3-1/8
2-1/2 2-1/2
2-19/32
10
3-1/8
2-1/2 2-1/2
2-5/8
2-1/2
12 3-3/32
2-1/2
3-3/32
3
Canvas Temp.
* F.
136 142 148 156 150 149 139 147 139 142 135 145 139 148 142 146 140 150 143 152 147 142
8. T. U. Loss Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
199 .4,020
220 5,020
249 6,240
283 7,850
288 8,940
311 11,140
290 11,140
359 16,260
337 16/260
384 20,810
364 20,810
437 25,620
412 25,620
490 30,410
463 30,410
549 39,420
523 39,420
650 48,950
608 48,950
738 57,900
690 57,900
650 57,900
Percent Eff.
%
95.0 95.6 96.0 96.4 96.8 97.2 97.4 97.8 97.9 98.2 98.3 98.3 98.4 98.4 98.5 98.6 98.7 98.7 98.7 98.7 98.8 98.9
DOUBLE LAYER ALLTEMP COVERING For 1300 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Size In. 14
16
18
Flat
Thickness Inches
Inner Layer
Outer Layer
* 2-1/2
2-1/2
3 2-1/2
33
2-1/2
2-1/2
*3 2-1/2
33
M/2
3
2-1/2
2-1/2
*3 2-1/2
33
3-1/2
3
2-1/2
2-1/2
*3 2-1/2
33
3-1/2
3
Canvas Temp.
F.
156 151 145 159 152 147 143 161 155 148 143 159 152 148 144
8. T. U. Less Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
806 63,480
755 63.480
703 63.480
900 72,400
838 72,400
783 72,400
741 72,400
985 81,380
920 81,380
849 81,380
811 81,380
155 17,630
142 17,630
131 17,630
121 17,630
Percent Eff.
%
98.7 98.8 98.9 98.8 98.8 98.9 99.0 98.8 98.9 98.9 99.0 99.1 99.2 99.3 99.3
Page 23
DOUBLE LAYER ALLTEMP COVERING For 1400 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Size In.
% %
1 l'/4 1% 2
3
4
5
6
8
10
12
Thickness Inches
Inner Layer
Outer Layer
3-11/32
None
3-1/4
None
3-5/32
None
2-31/32
None
3-11/32
None
*2-1/8
1-1/2
2-1/8
2-1/32
*2-1/16
2-1/32
2-9/16
2-1/32
*2-9/16
2-5/32
2-9/16
2-21/32
* 2-9/16
2-3/32
2-9/16
2-19/32
* 2-17/32
2-3/32
2-17/32
2-5/8
*2-11/16
2-1/2
3-1/8
2-1/2
* 2-19/32
2-1/2
3-1/8
2-1/2
*2-5/8
2-1/2
3-3/32
2-1/2
3-3/32
3
Canvas Temp.
* F.
141 148 154 162 156 155 144 153 144 147 140 150 144 153 148 152 145 156 148 158 153 147
B. T. U. Loss Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
220 4,960
245 6,170
277 7,680
316 9,660
320 11,010
346 13,720
323 13,720
400 18,860
376 18,860
428 25,690
406 25,690
488 31,640
459 31,640
545 37,580 .
516 37,580
614 48,740
582 48,740
725 60,540
675 60,540
825 71,640
769 71,640
724 71,640
Percent Eff.
Vo
95.6 96.0 96.4 96.7 97.1 97.5 97.6 97.9 98.0 98.3 98.4 98.5 98.5 98.5 98.6 98.7 98.8 98.8 98.9 98.8 98.9 99.0
Page 24
DOUBLE LAYER ALLTEMP COVERING For 1400 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Size In. 14
16
18
Flat
Thickness Inches
Inner Layer
Outer Layer
2-1/2
2-1/2
*3 2-1/2
33
2-1/2
2-1/2
*3 2-1/2
33
3-1/2
3
2-1/2
2-1/2
*3 2-1/2
33
3-1/2
3
2-1/2
2-1/2
*3 2-1/2
33
3-1/2
3
Canvas Temp.
F.
162 157 150 166 158 153 148 168 161 154 149 166 158 153 149
6. T. U. Less Per Lineal Ft. Per Hour
Covered Pipe
Eare Pipe
904 78,560
839 78.560
786 78,560
1.002
89,600
932 89,600
873 89,600
825 89,600
1,100
100,770
1,022
100,770
949 100,770
902 100,770
173 21,780
158 21,780
146 21,780
135 21,780
Percent Eft.
%
98.8 98.9 99.0 98.9 99.0 99.0 99.1 99.0 99.0 99.1 99.1 99.2 99.3 99.4 99.4
Page 25
DOUBLE LAYER ALLTEMP COVERING For 1500 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Size In.
Vi
%
1
IV* IVz
2
4
5
6
8
10
12
1
Thickness Inches
Inner Layer
Outer Layer
3-11/32
None
3-1/4
None
3-5/32
None
2-31/32
None
3-11/32
None
2-1/8
1-1/2
* 2-1/8
2-1/32
*2-1/16
2-1/32
2-9/16
2-1/32
*2-9/16
2-5/32
2-9/16
2-21/32
* 2-9/16
2-3/32
2-9/16
2-19/32
*2-17/32
2-3/32
2-17/32
2-5/8
*2-11/16
2-1/2
3-1/8
2-1/2
2-19/32
2-1/2
*3-1/8
2-1/2
2-5/8
2-1/2
* 3-3/32
2-1/2
3-3/32
3
00
-M
Canvas Temp.
0 F.
147 154 160 169 162 161 150 159 150 153 145 156 149 159 154
151 163 154 164 159 153
B. T. U. Loss Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
241 6,040
271 7,520
305 9,360
349 11,790
353 13,440
382 16,750
356 16,750
441 24,510
415 24,510
473 31,400
448 31,400
539 38,690
506 38,690
600 45,970
570 45,970
678 59,650
641 59,650
800 74,110
742 74,110
912 87,720
848 87,720
799 87,720
Percent
Eff. %
96.0 96.4 96.7 97.0 97.4 97.7 97.9 98.2 98.3 98.5 98.6 98.6 98.7 98.7 98.8 98.8 98.9 98.9 99.0 99.0 99.0 99.1
Pa<--
DOUBLE LAYER ALLTEMP COVERING For 1500 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Size In. 14
16
18
Flat
Thickness Inches
Inner Layer
Outer Layer
2-1/2
2-1/2
*3 2-1/2
33
2-1/2
2-1/2 '
3 2-1/2
*3 3
3-1/2
3
2-1/2
2-1/2
3 2-1/2
*3 3
3-1/2
3
2-1/2
2-1/2
3 2-1/2
*3 3
3-1/2
3
Canvas Temp.
* F.
169 162 156 172 164 159 154 175 167 160 155 173 164 159 154
8. T. U. Loss Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
1,002
96,200
923 .
96,200
869 96,200
1,104
109,780
1,026
109,780
963 109,780
909 109,780
1,215
123,440
1,124
123,440
1,050
123,440
993 123,440
191 26,620
175 26,620
161 26,620
149 26,620
Percent EH.
%
99.0 99.0 99.1 99.0 99.1 99.1 99.2 99.0 99.1 99.1 99.2 99.3 99.3 99.4 99.4
Pt|e 27
DOUBLE LAYER ALLTEMP COVERING For 1600 F.
* Indicates Recommended Thickness 80 F. Ambient Air Temperature
Pipe Size In.
%
%
1
Thickness Inches
Inner Layer
Outer Layer
3-11/32
None
3-1/4
None
3-5/32
None
1% 2-31/32
None
1% . 3-11/32
None
2-1/8
2
*2-1/8
1-1/2 2-1/32
*2-1/16
3
2-9/16
2-1/32 2-1/32
*2-9/16
4
2-9/16
2-5/32 2-21/32
* 2-9/16
5
2-9/16
2-3/32 2-19/32
* 2-17/32 6
2-17/32
2-3/32 2-5/8
*2-11/16
8
3-1/8
2-1/2 2-1/2
2-19/32
IQ
*3-1/8
2-1/2 2-1/2
2-5/8
2-1/2
12 * 3-3/32
2-1/2
3-3/32
3
Canvas Temp.
* F.
152 160 167 176 169 167 156 165 156 158 150 162 155 165 160 164 157 169 160 171 165 159
8. T. U. Loss Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
261 7.290
297 9.080
333 1U10 382 14,250
386 16,250
418 20,260
390 20,260
483 29,670
455 29,670
518 38,020
490 38,020
591 46,870
554 46,870
655 55,700
624 55,700
743 72^90
700 72^290
875 89,860
810 89,860
1.000
106,390
927 106,390
874 106,390
Percent EH.
%
96.4 96.7 97.0 97.3 97.6 97.9 98.1 98.4 98.5 98.6 98.7 98.7 98.8 98.8 98.9 98.9 99.0 99.0 99.1 99.1 99.1 99.2
Page 28
DOUBLE LAYER ALLTEMP COVERING For 1600 F.
* Indicates Recommended Thickness SO4 F. Ambient Air Temperature
Ripe Size In. 14
16
18
Flat
Thickness Inches
Inner Layer
Outer layer
2-1/2
2-1/2
3 2-1/2
*3 3
2-1/2
2-1/2
3 2-1/2
*3 3
3-1/2
3
2-1/2
2-1/2
3 2-1/2
*3 3
3-1/2
3
2-1/2
2-1/2
3 2-1/2
*3 3
3-1/2
3
Canvas Temp.
F.
176 168 162 179 171 165 159 182 173 166 161 180 171 165 160
B. T. U. Loss Per Lineal Ft. Per Hour
Covered Pipe
Bare Pipe
1,100
116,690
1,007
116,690
953 116,690
1,206
133,180
1,122
133,180
1,055
133,180
993 133,180
1,330
149,780
1,226
149,780
1,150
149,780
1,085
149,780
210 32^40
192 32,240
176 32^40
163 32,240
Percent Eff.
%
99.1 99.2 99.2 99.1 99.2 99.2 99.2 99.1 99.2 99.2 99.3 99.3 99.4 99.5 99.5
Page 29
Vhere to buy
{
ngineerlng service
Carey Industrial Sales Engineers can be easily reached at the District Offices listed below. Call on them for any information you need, or for the name of a Carey-approved contract unit in a major trading area near you.
District Offices
Atlanta 6, Ga. 251 Armour Drive, N.E. TRinity 4-5793
Boston, Maas. (Cambridge 38) 22 Moulton St. TRowbridge 6-7700
Charlotte 2, N. C. 402 Addison Bldg. 222 S. Church St. FRanklin 7-6502, 7-6503
Chicago District 25th and Warren, Bellwood, 111. AUstin 7-4063
Cincinnati 15, Ohio 316 S. Wayne Ave. VAlley 1-3000
Cleveland 29, Ohio 8551 Brookpark Road FLorida 1-8505
Dee Moines, Iowa 927-28 Insurance Exchange Bldg. CHerry 4-7113
Detroit 38, Mich. 14420 Livernois Ave. TOwnaend 8-2600
Houston 8, Texas 1400 N. Post Oak Road UNderwood 9-3363
Indianapolis 21, Ind. 1432 Kentucky Ave. MElrose 5-1314
Los Angeles 21, Calif. 1760 E. 15th St. Richmond 8-5207
Memphis, Tenn. 1510 Orendo Road JAckson 7-3081
Montreal 9, P.Q. 95 Stinson Blvd. Ville St. Laurent Regent 1-6451
New York 17, N.Y. Lincoln Bldg., 60 E. 42nd St. MUrray Hill 7-1530
Philadelphia 32, Pa.
24th & Sedgley Ave.
BAldwin 9-6430
Pittsburgh 20, Pa. 1018 Saw Mill Run Blvd. HEmlock 1-6334
St. Louis 3, Mo. 307 N. Theresa Ave. JEfferson 1-1930
San Francisco 24, Calif. 101 Williams Ave. Mission 8-4400
Seattle 4, Wash. 505 Dexter Horton Bldg. SEneca 2351
ALLTEMP is the newest and latest formulation in the Carey line of Industrial Insulations. Other famous products developed by Carey include Super-Light 85% Magnesia, Hi-Temp No. 19, MW-50 In sulating Cement, MW-1 Insulating and Finishing Cement, Asbestos Cement and a complete line of Bonding, Finishing and Refractory Cements. Carey Engineering Service will help you determine which type of insulation is the best suited and most economical for your particular requirements, and will show you how it can be used to best advantage. Call on Carey any time.
after products for industry since 1873
The Philip Carey Mfg. Company
Lockiand, Cincinnati 15, Ohio In Canada: The Philip Carey Co., Ltd., Montreal 9, P. Q.
LIST PRICES PIPE COVERINGS & BLOCKS
industrial insulation
The following list prices are to be used for pricing all Carey pipe coverings of corresponding thickness, except that !' thick list pries are to be used for pricing all pipe coverings of I' or less thickness.
NOTE: All pipe coverings, blocks and sheets while quoted in terms of following List Prices less discount are actually priced at net unit prices appearing in "Manual of Unit Prices" which are essentially the same as list prices less quoted discount.
SPiimpe*
1 Inch Thick
Plic--a--p a
Feat
i
Plica par Ijaiaal Fast
2 lack Thkkaaaa
Pnca par Liaaai Fact
2H lack Thickaaaa
Pnca pat Faat
5 lack Thickaaaa
Prica pat Lineal Faat
J!: Inch Thickness 4 Inch 4V? Inch 5 Inch
Inch * Inch
(Ooabia Thickness Thickness Thickness Thickness Thickness
Layar)
Prica Par Pries Per Prica Par Pries Par Pnce Par Price Per
Lineal
Lineal
Lineal
Lineal
Lines!
Lineal
Feet
Font
Feet
Foot
Foot
Feat
inches K v;
l*
\M
IK 2
2H 3
$0.22 *C .24 *C .27 *C .30 *C
.33 .36 *C .40 *C .45 *C
$0.46 *C .49 *C
.52 *C .56 *C
.60 *C .64 *C
.70 *C .76 *C
$0.75 *C .80 *C
.85 *C .90 *C
.95 < 1.00 *C
1.05 *C 1.15 *C
$1.00 *c $1.20 *C 1.05 *C c 1.35 *C 1.10 *C . 1.40 *C 1.15 *C 1 1.45 *C
1.20 *C N 1.55 *C 1.25 *C G 1.65 *C 1.35 *C L 1-75 *C 1.50 *C *. 1.90 *C
$1.55 4 $1.95 4 1.7S 4 2.15 4 1.80 4 2.20 4 1.95 4 2.35 4
2.00 4 2.40 4 2.10 4 2.45 4
2.25 4 2.70 4 2.35 4 2.85 4
$2.40 2.55 2.60 2.80
2.90 3.00 3.25 3.40
$2.90 3.10 3.15 3.45
3.50 3.60 3.90 4.00
$3.45 3.65 3.70 4.00
4.05 4.10 4.45 4.60
$4.05
4.20
4.25 4.45
4.65
4.75
5.10
5.25
f 3H 4'
.50 *C .60 *C
.82 *C .88 *C
1.25 *C 1.35 *C
i.ti C i.bs *C 2.60 4 3.15 f 3.70 1.80 *C . 2.20 *C 2.70 4 3.30 4 3.80
4.35 4.45
5.00 5.10
5.65
5.7S
4H 5
.65 *C .70 *C
.94 *C 1.00 *C
1.45 *C 1.55 *C
1.95 -C L 2.35 *C 2.95 4 3.50 4 4.10 2.10 *C A 2.50 *C 3.00 4 3.55 4 4.15
4.80 4.85
5.SO 5.55
6.20 6.2S
6 .80 *C 1.10 *C 1.70 *C 2.25 *C V 2.70 *C 3.30 4 3.90 4 4.50 5.30 6.00 6.70
7 1.00 *C 1.20 *C 1.85 *C 2.40 -C E 2.90 *C 3.60 4 4.25 4 4.85 5.75 6.SO 7.35
8 9
I.10 1.20 *C
1.35 *C 1.50 *C
2.00 *C 2.20 *C
2.55 2.80
*C *C
RK
3,5 3.40
#C *C
3.85 4.55 4 5.25 4.20 4.90 5.60
6.10 6.65
7.05 7.50
7.85 8.35
ib 1.30 *C 1.65 tC 2.40 JC J.oi tc 3.654E 4.65 5.40 6.15 7.10 8.05 9.00 1! 1.75 JC 1.75 $C 2.55 tC 3.20 tC 3.90+E 4.90 5.70 6.50 7.50 8.50 9.SO 12 1.85 tE 1.85 tE 2.70 tE 3.40 tE 4.I04E 5.15 6.00 t 6.85 7.90 8.90 9.90 14 2.10 tE 2.10 ?E 3.00 tE 3.80 tE 4.60 tE 5.55 t 6.50 t 7.45 8.S5 9.60 10.60
IS 2.25 tE 2.25 tE 3.15 tE 4.00 tE 4.85 tE 5.85 t 6.85 t 7.85 8.95 10.00 11.10 16 2.35 tE 2.35 tE 3.30 tE 4.20 tE 5.10 tE 6.15 t 7.15 t 8.15 9.30 10.45 11.60 17 2.50 tE 2.50 tE 3.45 tE 4.40 tE 5.35 tE 6.45 t 7.50 t 8.50 9.70 10.90 12.05 18 2.60 tE 2.60 tE 3.60 tE 4.60 fE 5.60 tE 6.70 t 7.80 t 8.85 10.10 11.35 12.50
19 2.75 tE 2.75 tE 3.80 tE 4.80 tE 5.80 tE 7.00 t 8.10 t 9.25 10.55 11.75 13.00 20 . 2.85 tE 2.85 tE 4.00 tE 5.00 tE 6.00 tE 7.25 t 8.45 t 9.55 10.85 12.20 13.50 2! 3.00 tE 3.00 tE 4.15 tE 5.20 tE 6.25 tE 7.50 t 8.75 t 9.90 11.25 12.65 13.90 22 3 10 tE 3.10 tE 4.30 tE 5.40 tE 6.50 tE 7.85 t 9.05 t 10 25 11.65 13.05 14.45
"13-------
24 26
3.20 tE 3.30 tE
3.55 tE
3.20 tE 3.30 tE
3.55 tE
4.40 tE 4 50 tE 4.85 tE
5.60 tE 5.75 tE
6.20 tE
6.75 tE 8.05 1 9.35 t 10.70 7.00 tE 8.25 t 9.65 t 11.00 7.50 tE 8.85 t 10.35 t 11.80
12.05 12.45
13.25
13.55 13.90
14.85
15.00
15.35 16.40
27 3.65 tE 3.65 tE 5.05 tE 6.40 tE 7.70 fE 9.15 1 10.60 t 12.05 13.65 15.20 16.65 28 3.75 tE 3.75 tE 5.15 tE 6.65 tE 7.95 tE 9.45 1 11.OS t 12.45 14.05 15.65 17.15 30 4.00 tE 4.00 tE 5.50 fE 6.95 tE 8.40 tE 10.00 1 11.55 t 13.00 14.70 16.40 17.95 \ 32 4.30 tE 4.30 tE 5.90 tE 7.40 tE 9.10 tE 10.50 1 12.10 1 13.85 15.45 17.15 19.00 33 4.40 tE 4.40 tE 6 05 tE 7 (SO fE 9.20 fE 10.70 1 12.45 t 13.9S 15.75 17.60 19.25
APPLYING ONLY TO.FILTER MOLDED $$% MAGNESIA
* Sections (semi-cylindrical) 36' long, f Segments (curved blocks) 36' long x approx. 6' wide,
t Sections or segments. 41st layer sections or segments, tad layer segments. # 1st layer sections, tad layer sections. 1st layer sections, 2nd layer segments.
C Furnished with canvas.
O No canvas, but will be furnished without extra charge if ordered.
E No canvas. Additional charge if ordered.
For pipe sixes over 33' locomotive lagging blocks must be used and prices figured on a square foot basis, See table of quantities and areas at bottom of page 3.
APPLYING TO ALL LAMINATED ASBESTOS t FELT PIPE COVERINGS
All laminated asbestos and felt pipe coverings are furnished in split cylindrical or semi-cylindrical sections complete with canvas and bands.
SHEETS AND BLOCKS
The following list prices are to be used for pricing all Carey sheets and blocks of corresponding thickness.
TTwikiiw K inch 1 inch
inch IK inch
Pi in Sqnara Faat
$0.2? .30 .34 .38 .42
Thiekaaee
1 K inch IK inch 1K inch 1K inch 2 inch
Prica Sqnara Faat
$0.45 .49 .53 .57 .60
Thickaaaa
2K inch 2K inch 2H inch 2K inch 2H inch
Pnea Sottfe Feot
$0.64 .68 .72 .75 .79
Thkkaaaa
2K inch 2K inch 3 inch 3K inch 4 inch 4K inch
SqnParraiesFaat
$0.83 .87 .90
1.05 1.20 1.35
85% MAGNESIA
indussttrriial I
List Pricas (par linaar foal) and Thickness Schedules insulaattiioon I
COPPER TUBING
Pipe Pipe Nominal Size O. D. 1' Thick
Th*k List K' .375 IK $.22
X' J00 i!4 .22
"w X'
1'
IK'
.625 J7S 1.125 1.375
lK l
K ihi
.22 .24 .27 .30
Pipe Size
K'
W
STANDARD STEEL OR W. I. PIPE
Pipe O. D.
Nominal
Minimum
Ncminal
1'Thick Double Layer IK Thick
Ncirnmal 2' Thick
.540 .675
Th*k List
156 156 s-i -a .22
ThTc 2-.~S.
List $.75
.75
ThTc
List
Th*k List
Nominal 2K' Thick
ThTc List
No:ninal 3"[hick
Th*k
List
K'
X9
i'
IK'
J40 1 t.l/i .22
.75 1% i-i,l$.46 2V6 i.i/^.75 2*56 $1.00 _56_ *31.30
1.050 tt i.t/i .24
.80 ltt uia .49 1*56 4.1/1 JO 2*56 4 1.05
1 1J5
1.315 156 * .27 -an. .85 ltt 4 J2 2K J5 2*56 4 1.10
7 1.40
1.660 tt i JO i% .90 lH 4.1/1 J6 1*56 > .90 2>56 4 1.15
7 1.45
IX' 1.625
JO
2' 2.125
J6
2K' 2.625 % .40
3' 3.125 % .45
IX'
2'
2K' 3'
1.900 2.375 2.875 3.500
l!4 s-i/i J3 _25i_ J5 156 4 J6 -JkL 1.00 156 4.1/1 .40 -2H. 1.05 156 f .45 _25. 1.15
iK 4.1/1 .60 2K
ltt i .64 2K 4
IH .70 2H 7
156 4 .76 256 T
.95 2K t
1.00 2x t
1.05 2K f 1.15 256 i
1.20 J}i_
1.25 IK-- 1J5 _Si=
1J0
* 1J5 * 1.65 1.75 1.90
K' 3.625 xMl JO
4' 4.125
.60
<K' 4.625 i% .65
5' 5.125
.70
3K' 4'
4K' 5'
4.000 4.500 5.000 5J63
156 156 < 156 t 156 t
.50 _2*JL 1.25 .60 -25JL US .65 2*Kl 1.95 .70 2.10
IN i
156 7 IN S
ltt t
J2 256 J8 256 .94 256 1.00 256
i s < >
1.25 1J5 1.45 1J5
2>?6 f 1.65 *4- 10 2.05
256 i 1J0 3*^_ 10 2.20
2rXt to 1.95
11 2J5
256 la 2.10 -Iris 11 JJO
6' 6.125 i\k .80 6' r V
9'
6.625 1
% JO _iM= 2.25 IK * 1.10 256 w 1.70 2tt u 2.25 3J6_ 2.70
7.625
09 CQ v
1X to 1.20 256 11 1J5 256 11 2.40 3K- u 2.90
8.625 I 9.625
cue.' S V to g 25
ltt ll 1J5 256 is 2.00 2*56 14 2.55 1K- 3.15
IX tl 1.50 256 14 2.20 2*56 u 2.80
" 3.40
is 10' 10.75 E
j 11' 11.75
3 12' 12.75 V
u
14' 14.00
hi IS' 15.00 Sl
16' 16.00 (**
17' 17.00 Sg 18' 18.00
5 5 oj
L. ^ *>. *
III
U-J.U = j:
ill
m 14 i if
i i
iK it
1.65 256 18 1.75 256 18 1.85 2K IT 2.10 2 ll
2.40 2tt 2J5 2K 2.70 2K 3.00 2K
18 3.05 -&L IT 3.65
it 3.20
u 3.90
u 3.40 _iJ6_ i 4.10 ll 3.80 _4_= *6 4.60
iK 18 IK >* IK to iK n
2.25 2 2J5 2 2.50 2 2.60 2
ll 3.15 2K 18 4.00
4J5
3J0 2K ll 4.20 i. _ MfS.10
3.45 2K is 4.40
MfSJS
n 3.60 2K tt$ 4.60 _2__ *4f5.60
Black figures in thickness columns indicate '`prime" solid sections.
Red figures in "TH'K"
indicate 2 layer assembled sections. Nominal 2' and 2K# thick assemblies can be cemented on
request to form one piece. Red figures in ``List" columns indicate outer layer pipe sizes that will make exact fit.
Indicator ( ) means nominal 1' thick.
( --) means nominal U4' thick.
C---) means nominal 2' thick.
Example:--6' pipe size, nominal 3'thick shows -314-which means first layer nominal IK* thick, second layer nominal IK'
thick to make total 3-K# thick.
tinner layer sections--outer layer segmental blocks.
JSegmental blocks.
NOTE: Assembled double layer sections will be priced on the basis of the list prices in above tables for such assemblies.
Special thicknesses to and
4' can be supplied by combining layers of above prime sections in multiple.
SIZES OYER 18"
RedNumeral,
For diameters over 18', to andincluding 33". segmental blocks approx. 6' wide by 36* long are furnished.
indicateblocks
` * `"
per section
IK'Thick 2' Thick
2K' Thick 3' (2-layer)
19' 20' 21' 22' 23' 24' 26' 27' 28' 30' 32' 33'
1:8 $2.75x 1] $2.85 12 $3.00xj: 33.10 13 $3.20xh $3.30 is $3.55 is $3.65 16
3.80X 4.00
4.15* 4.30
4.40x 4.50
4.85
5.05
$4.00 u $4.30* u $4.40*17
5.50
5.90 i< 6.05Z]9
4.80* 5.00
5.20x 5.40
5.60* 5.75
6.20
6.40
6.65
6.95
7.40
7.60xi9
5.80* 6.00x 6.25 13 6.50* 6.75* 7.00
7.SO
7.70
7.95
8.40
9.10* id 9.20X1O
Size
1 ' x 6' x 36' IK' x 6' x 36' IK' * 6' x 36'
IX* X 6' X 36' *2 ' x 6' x 36'
List Price Per Sq. Ft.
$0.30 .38 .45 .53 .60
FLAT BLOCKS
Size
2K' x 6' x 36' 2M' x 6' x 36' 3 ' x 6' x 36' 3K' x 6' x 36' 4 ' x 6' x 36'
List Price Per Sq. Ft.
$0.68 .75 .90
1.05 1.20
Size
IK* x 12' x 36' 2 ' x 12' x 36' 2K* x 12' x 36' 3 ' x 12' x 36' 3K' x 12' x 36' 4 ' x 12' x 36'
List Price Per Sq. Ft.
$0.45 .60 .75 .90
1.05 1.20
LIST PRICES -- ALLTEMP
Including thickness tables and working sizes for
COMBINATION COVERINGS
industrial insulation
f" Csss/.
MINERAL WOOL PIPE INSULATION
UST K1CI PCX LINEAL FOOT--CRATED
industrial insulation
Tba bold tenia imanartiataly briar the lilt pnea indicate the appmnutt ehipping weight per linal loot.
______________________ _________ ___________________ ____
THICKNESS______________________________________________ _
PIPE SIS IN
INCHES NOMINAL
2* 2H* 3*
3H* 4*
<H*
S'
8* 7*
r a*
9* io* 12*
1* THICK
80.70
1.7
.75
24 JB
12 .9S
u
LOS
25
L15
35 US 32
US
34
L50
35
LOS
42
US
45
2.00
55
2J0
55
1H* THICK
10.90 35 1.W 32
uo
35
uo
35
UO
45
L40
45 150 4.7
LOS
5J
US
55
L9S
SJ
2.15
75 255 75
2.70
17
2* THICK
S1J0
45
L40
55
L50
55
L80
55
L70
55
L85
65
2.00
U
2JS
75
2.20
12
2.50
10
2.75
95
8.00
105
8.20
125
2H* THICK
81.85
62
L75
74
L85
72
1.95
75
2.06
12
2J0
17
2JS
92
250
105
2.70
115
2.96
125
SJ0
125
850
117
3.80
155
2* THICK
8220
9.0
2.30
94
2.45
105
2.00
102 2.75
10.7
2.90
112 8.06
115
3.30
135
355
145
3.80
155
4.10
16.1
4.40
174
4.80
195
OUTSIDE DIAMETER
8350
8100
8100
8420
14* 64 12 117 162
2.80 130 4.00 4.00
16* 74 102 145 110
SJ0 100 4.40 100
18* 15 112 152 205
3.40 100 450 100
20* 62 122 174 212
4.00 440 160 140
34* 105 155 205 265
100
8.80
180 . 7.80
30* 110 165 242 302
Funiiahed in 2-loot length!. Expanded motel lath oo outride. Stnpa of p--wUd matal lath oa tba
85.30
202 180
222 6.30
242
190
262
7.00
302
0.40
372
4* THICK
(3.10
115
3.25
142
3.40 110 355
165
8.70
165
3.85
172
4.00
111
4.20
204
450 20.6
450 222
5.10
24.0
5.50 210
8.00
272
8150 300
UO
320 7.00 340
8JO
370 9.50 430
11.20
520
\ jriovs types of Carey Mineral Woof blankets
STYLE NO. WO--1-in. (alvmnixad true mah both ridn. For flexibility--oo plaaur baaa.
STYLE NO. W1--1-in. galvamaed win mah oa aida ixpamiad maUl lath other aide. For flexibility and plaata baa ana aida.
STYLE NO. *02--Metal lath both ridaa. For flexibility and plaata baa both ridaa.
STYLE NO. *08--%-in. lib lath (rib In) ana ride 1 In galvanized wire meah other aide. Rigid ooe rida and plaata boa on aide.
STYLE NO. tOSA--H-in. rib loth (rib oat) one aide--1-in. galvamaed win mah other aide. Rigid ooe ride and tumiehn a H-in. air apana im plailir baaa.
STYLE NO. *04--H-in. rib lath (rib in) one nth metal lath other aide. Rigid one ride and plaata baa both aidn.
STYLE NO. *0tA--H-in. rib lath (rib ant) ana rida mr*al lath other nde. Rigid one aide with H-in. air apace and pleater baa ana rida.
STYLE_NO.JriA--^-in. rib loth (rib in) ana rida 1-in. galvaniead
Rigid one aide and plaata baa ana rida.
STYLE NO. S06A--H-in. rib lath (rib ont) ooa aide--1-in. galvaoiad win meah other aide. Rigid one rida and funnahaa a H-in- air apnra no plaata baaa.
STYLE NO. Mt--H-in. rib lath (rib in) one -J- --lath othw aide. Rigid one rida and plaata ban both ridaa.
TLE NO. tOOA--H-in. rib lath (rib ari) one ride, matal lath othm aide. Rigid one ride with H-in. air apaee and plaata ban one aida. STYLE NO. *08--H-in. rib lath (rib in) both aidn. Rigid both aidn nod p*"*** ban both ridaa.
STYLE NO. *00--H-in. rib lath (rib out) one aide--H-in. rib lath (rib in) otha aide. Rigid both aidn end tomiahea H-in- air apace one rida and plaata ban otha ada.
LIST PRICES PER SQUARE FOOT
The bold figure! immediately below the liet prion indican the approximate
ehipping weight pa aquare toot.
____
V
STYLE THTC
1V4TH'K
2* TH'K
&K
8' THTC
T$K
4* TH'K
B*
TH'K
' THK
300 301 303 303 303A 304 SOLA 300 301A 306 308A 308 309
(0.50 IM
0.55 LS5
0.66 L76
0.55 155
0.55 1.95
0.70 1W
0.70 2.96
0.7D 119
0.70 820
0.85 1.95
0.85 125
0.85 825
0.85 825
(0.55 Sett
0.85 (29
0.70 I.M
0.85 8.46
0.55 9.49
0.75 *55
0.75 855
050 8.85
050 *55
0.05 I.7S
0.96 8.75
0.95 1.99
0.95 *59
(0.60 t.M
0.70 t.75
0.73 189
0.80 180
0.70 t.9fl
0.80 119
0.90 110
190 t.W
0.90 190
LOO 139
LOO 136
LOO 135
LOO 185
(0.70 1*5
0.80 140
055 850
0.90 190
0.80 3.60
0.90 178
0.90 178
1.00 188
LOO 8.88
L10 185
L10 185
L10 4.00
L10 4.90
30.80 8.88
0.90 4.09
0.95 119
LOO 429
0.90 4.W
LOO 185
LOO 185
UO 4.45
L10 145
120 455
120 455
1.20 4.80
L20 4.90
10.88 4.49
0.96 458
L03 4.85
LOS 178
0.98 175
LOS 1*6
LOS 180
LIS 6.00
L18 8.00
L28 820
128 820
1.28 825
128 8.28
10.95 100
LOS 115
U0 825
L15 185
1.05 5.85
L15 189
US 550
125 190
125 190
L35 (.70
125 170
1.35 175
1.35 5.75
(1.10 6.26
1.20 135
L25 145
120 055
1.20 185
uo 170
1.80 IN
L45 6.80
L45 180
L55 IM
155 8.80
155 0.95
155 (25
$1.25 7.45
L35 7.80
L40 7.79
L45 758
1.35 158
L4S 1.16
L45 7.96
L65 1(6
L65 195
L7S 115
L78 115
L75 9.99
L75 9.99
" Above price! an for Carey Mineral Wool Blanket! in etandard aim aheeta,
PIPE COVERING WEIGHTS AND PACKAGING DATA
industrial insulation
IN POUNDS PER THREE-FOOT SECTION (Net Weight)
PIPE SIZES -- INCHES
KIND OF COVERING Inches X % ; 1 1* IX 2 2* 3 3% 4 *X 5 6 7 8 9 1 10 1 1=
Super Light 85% Magnesia
1
L4 1.3 2.0 1.8 2.3 X7 3.1 3.5 5.2 4.4 6.1 5.0 5.6
Super Light 85% Magnesia
2.9 24 X5 44 XO X7 44 5.9 54 7.0 6.1 8.0 9.0 10.5 11.5 12.7 14.4 16.7
. Vin.
Super Light 85% Magnesia DhLLayer 4.5 4.4 5.5 54 7.5 7.1 94 8.5 10.8 10.0 16.6 15.5 17.1 25.0 27.0 29.4 31.3 354
Super Light 85% Magnesia
2
4.5 4.4 5.5 54 74 7.1 94 8.5 10.8 10.0 9.11 11.4 13.0 14.5 16.0 18.6 19.7 23.3
Super Light 85% Magnesia
5.7 8.0 7.8 7.6 10.1 9.7 94 1L5 1X1 13.3 16.6 15.5 17.1 ... 22.0 24.0 25.2 29.7
Super Light 85% Magnesia
8
8.0 10.6 10.5 104 1X1 1X7 124 1X8 18.2 17.4 20.6 19.5 21.7 24.9 27.0 29.4 31.3 354
Alltemp.'.......................... .
1 L5 L7 X3 24 X4 X5 X0 4.6 5.1 X3 64 74 8.6 11.0 12.2 13.4 144 21.1
Alltemp....................................
1*
X2 XI 4.5 4.7 54 5.7 X4 7.3 XI 84 94 10.4 1X9 13.4 1X6 16.3 17.9 21.1
Alltemp....................................
2
5.9 XI 8.4 7.0 7.6 X6 9.6 10.8 114 1X0 13.7 15.1 16.9 184 204 23.6 25.0 29.1
Alltemp.................................. . DW.1* 11.9 11.8 13.5 1X2 1X9 1X7 16.0 19.8 18.8 2X8 21.6 25.6 2X4 32.1 34.6 38.3 40.7 46.6
Careycel.............................. 1 2.1 24 X4 24 XI X5 XO 44 X6 5.3 5.7 64 74 7.9 8.5 10.8 11.5 12.7
Asbestos Sponge..................
1
3.8 X3 X2 XO 7.0 74 &0 94 104 11.3 1X0 13.6 15.0 15.7 19.0 19.7 23.8 27.8
Air Cell....................................
1
1.8 L7 L8 L9 XO 2.4 2.7 XO X3 34 4.2 X9 5.3 6.1 6.9 8.2 8.0 9.6
Air Cell....................................
X
L2 L2 14 L4 L6 L9 24 2.5 X7 3.3 3.4 3.8 4.3 44 5.4 6.1 6.6 8.0
Air Cell....................................
X
0.9 L0 14 14 X3 14 L6 L9 24 X3 2.5 X7 XO 3.3 3.8 4.2 4.7 5.6
Impervo................... ...............
%
2.1 X2 24 X0 34 X7 44 X7 54 5.7 64 64 74 X9 10.0 11.0 1X0 14.1
Impervo..................................
X
L3 L4 L8 L9 24 24 2.9 34 3.6 4.0 44 44 5.7 X3 7.1 7.9 8.7 10.2
Impervo................... ............... DbL% 5.1 5.5 XO X7 74 84 9.0 104 1L0 124 1X2 14.3 1X4 18.3 20.2 22.4 24.5 28.9
Impervo.................................. DhL* 34 3.4 34 44 X6 54 5.8 X7 7.4 XI X9 6.1 114 1X7 1X0 154 174 19.7
Perfecto,,**...........................
1
2.1 X3 24 XO 34 X4 X9 X6 XO X3 54 94 74 8.4 10.7 1X2 13.5 15.6
Perfect..... ............................
X
1.3 L5 14 XI X3 X4 XO X7 XI 44 X9 5.1 X7 X7 7.7 8.6 94 114
Perfecto...................................
X
0.8 L0 14 14 L6 L7 L9 X3 24 24 XI X4 X8 4.7 64 6.1 7.0 8.2
Perfect................................... DM. fc 3.4 4.0 4.6 5.0 54 X3 74 X3 9.0 10.1 11.2 12.2 14.2 15.9 17.6 19.7 21.6 25.0
Perfecto.................................. DbL% X3 2.5 XO 34 34 X6 XI 4.9 6.3 X6 64 6.6 7.7 8.9 114 124 14.3 16.2
1 L2 L3 1.7 X3 24 X6 X3 X6 XI X7 5.1 5.6 XI 6.7 74 84 9.6 114
Defender............................ .
1
3.0 i X2 3.4 X7 X4 6.1 5.8 6.5 6.9 7.2 7.6 XO 9.4 104 12.2 13.6 15.0 18.0
F. M. 85% Magnesia weight! same as Alltemp.
..
The weight! given in the table* are subject to some variation, but represent averages from which fairly accurate estimates can be
made. These weights are not guaranteed.
'*
Carton Data--Asbestos Blocks and Sheets
PIPE COVERINGS (Low Pressure)
industrial insulation
Cartons (AH Coverings except Asbestos Sponge) Approximate Number of 3 Foot Sections Per Carton
Nominal Pipe Size
H'
4'
i' 14'
2' 2UW
3# 34'
4*
4H' 5' 6' 7' 8' 9' 10' ~ 12'
For Standard Steel Pipe Thicknesses
W 4' 1' l 4' i4' 2'
60
55 35 28 18 15 9
42 30 23 15 12 8
30 24 18 12 11 7
24 20 15 12 11 6
20 15 12
986
15 12 11
665
11 9 8 6 6 4
9 8 6 5 54
g 6 6 444
6 5 5 444
s 5 4 333
4 4 4 2 23
4 4 4 2 23
4 4 3* 2 2 2
3 2 2 222 2 2 2 2 1*
2 2t 1 1* 1*
Nominal For Copper Tubing --Thickness
Copper O.D.of
TubeSize Copper 4' K' 1' 14' Tube
%
4' 77 4' 73
60 42 54 35
20 18
4' 4' 54 42 30 15
i' 14' so 35 28 15
i vs 1*4' 40 30 23 12 l 4' l4' 30 24 18 12
2' 24' 24 18 15
9
24' 2*4' 18 15 12
7
3' 34' 15 12 9 6
34' 34' 12 9 8 6
4' 44' 8 6 6 4
S' 54' 6 5 4 3
6' 64' 7 4 4
8' 84' 8 4 3
Carton Size: 134' * 194' * 36' Carton Weighs: 5 lbs.
36' Car holds 360 cartons 40' Car holds 450 cartons 40' x 10 Car holds 550 Cartons 50' Car holds 670 cartons
Carton Si*e: 18' x 18' x 37' Carton Weighs: 6 lbs.
f . 1 see. Impervo, Perfecto, Proteeto * . 2 see. Impervo, Perfecto, Proteeto
Cartons (Asbestos Sponge Only) Approximate Number of 3 Foot Sections Per Carton
Tominal ipe Size
4' 4'
l' 14' 14' 2' 24' 3' 34' 4' 44' 5' 6' 7' 8' 9' 10' 12'
Thickness
1' 14'
15* 8' 12* 6* 12* 6*
9* 6* 8* 5*
6* 4*
5* 6 86 6S 64 54 44 42 42 23 22 21 21
2'
5* 4* 4* 4* 3* 5 4 3 3 3 2 2 2 2 2 1 1 I
3*
5 4 4 4 4 4 3 2 2 2 2 2 2 1 1 1 1 1
Carton Size 134' * 194' x 36' Carton Weighs: 5 lbs.
Half Carton Size 104' * 134' x 36'
Carton Weighs: 24 lbs.
36' Car bolds 360 cartons 40' Car bolds 450 cartons 40' z 10 Car bolds 550 cartons SO' Car holds 670 cartons
.
PACKAGING 85% MAGNESIA and ALLTEMP
industrial insulation
PACKAGING
AH tires and thidoaesses of 85% Magnesia and Alltemp pipe coverings and bloda are packed in cartons for domestic shipment as shown in the following tables:
INSULATION PACKAGING
Pip* Sica
1/4 3/S
MOW. 1* THICK
5m Pi Pk Ca Type
Gcaa* Vi.
Sap** Allttap Licks F.P
36 32 36 52
64 51
76 73
NOW. 1-1/2* THICK
Sac Pf Cia
Pkp Typa
Gcaa* Vi. *Pt AJUaap LUbl F.P.
25 53 23 53
61 79 60 7*
NOW. 1* THICK
Sac Pk.
Oiaa* Vi.
Pat Ct*
Typa
Sapat AlMaaay LUbi F.P.
16 33 16 55
79 76
99 96
NOW. 2-1/2* THICK
Sac Oiaa Vi.
Pat Ct*
Typa
Sapat Litbt
Alli.ap F.P.
31 33 31 37
71 71
NOW. 3* THICK
Sac Pat Ci*
Pk|. Typ*
Oraa* *. I Sapat Ailic--p | Li.br F.P.
9 35
?S
9 35 7S
102 102
1/2 3/4
1 1-1/4
1-1/2 2
2-1/2 3
3-1/2 4
4-1/2 5
6 7
S 9 10 11
12 14
15 16
17 IS
36 52 36 32
23 S3 25 55 25 53 16 33 16 55
9 31
9 35 9 55
sS 39 59
4 32 --
---_
-__
----
57 73 25 55 79 100 34 6S 23 55 77 96
16 55 16 55
60 79
97 94
33 77 35 77
35 70 16 S3 62 77 50 63 16 55 74 *9
63 SI 16 55 71 S3
30
39
9 31
41 59
37
67
9 35
64 64
37
49
9 55
60 75
9 51 9 31
33 53
63 68
9 S3 9 35
7> 72
94 91
I 59 S 59
61 74
101 97
55 76 55 76
59 66 39 63
32 33 52 32
34
67
S 59
67 SS
47
5*
S 59
63 SO
4 52 4 32
49 46
St 36
34 64 54 61
56
70
4 52
41 S3
47
59
4 32
38 44
4 34 4 34
53 53
71 64
36 74 56 7P
21
34
4 54
43 34
-
-
4 56
49 62
4 56 2 37
39 34
76 49
37 40 36 43
2 57
21 37
-
-
2 31
31 39
2 36 2 36
36 43
46 33
36 30 39 34
-
-
2 36
34 46
-
-
2 39
37 49
2 59 1 31
43 27
36 33
31 30 31 33
_
_
1 31
22 27
--
1 31
22 -
1 31 1 33
29 30
-
33 36 34 36
_
-
1 53
24 -
--
1 34
27 -
1 54 1 33
31 33
-
33 40 36 41
-
-
1 33
27 - .
1 36
36
-
- 41
-
-
1 36
30 --
1 - 33 -
--
--
101 1 59 90 99 6 59 90
96 6 59 90 96 59 86
112 4 52 58 106 4 52 56
69 4 34 67 65 4 54 67
79 4 36 78 76 4 36 77
94 2 37 46 86 2 57 44
30 2 36 49 56 2 58 34
63 2 39 59 69 1 31 36
36 1 31 37 - 1 33 39
- 1 54 44 - 1 35 45
- 1 36 4*
-
--
-
-
--
-
-- ---- -
Pip* Caaatia* Can**a--Typa* aarf Siaa* (Oaai4* P^aaiit--)
.. -S.f-.hK
Nw 51-17-1/2** 17*1/5* *36-7/** -6J35
N*.52-18** ll*i 36-7/S*
.*.914
N*. 55- 1*3/8* s 16-3/8* * J4-7/S* . 7.403
W* 34--19-7/8* s 19*7/1* * 36*7/8* *8^30
A*. 35-2>5/8* t 20-3/1* t 367/8* - 9.078
N*. 36-22** 22* a Sfr-7/6
' .10.52*
Na. 37-24-1/t* 112-l/S* s 3*>7/S* 6J42
N*. 3S --2P3/S* s 14*1/2* * 36-7/8* * 8.857
N*. 39-31-1/4*8 15-5/4** 36-7/8* -10.303
N*. 60-22-3/8** 16-1/8* 36-7/8* *7.699
lit 117
114 114
7) 61
66 17
105 97
59 57
63 72
0 44
-
-
--
BLOCK PACKAGING DATA - FLAT BLOCKS
Super-Light 85% Magneslo
Filter Press 85% Magnesia, Alltemp and HI-Temp No. 19
Block Size
flocks Per
Carton
Croat Weight
Block Size
Blocks Per
Carton
___________ Gross Weight
Filter
All-
Hi-
Carton
Press
temp
Temp
1 " x 6" z 36" lk" z 6" z 36" iH" z 6" z 36" 2 " z 6" z 36"
2H" z 6" x 36" 3 " z 6" z 36"
36 28 24 18 14 12
53
SlH S3 53
siH 53
Super-Light Flat Blocks sacked in Carton Type 40 with outside size of 12k" * 18H* z 36H"-
Cu. Ft. 5.117
I " z 6" z 36"
lk" z 6" z 36" 1H" z 6" z 36" 2 " z 6" z 36"
2H" z 6" z 36" 3 " Z 6" z 36"
24
20 16
12 10
8
6" x 36" 6" z 36"
6 6
Carton Size (outside dimension)
CN-1 CN-5 CN-1 CN-1
CN-S CN-1 CN-1 CN-1
51 53 51 51 53
51 51 51
60
63 60 60
63 60 60 60
No. CN-1 12k" x 12K' z 37".
No. CN-5 - 12k" x 13X' x37".
87 93 87 87 93 87 87 87
3.481 cu. ft. 3.583 cu. ft.
BLOCK PACKAGING DATA - SEGMENTAL BLOCKS
Super-Light 85% Magnesia
Filter Press 85% Magnesia, Alltemp and Ht-Temp No* 19
Block Size
Blocks Per
Carton
Grots Weight
Nominal Pipe Size
No. of Segments per Section
AB Thicknesses
No. of Blocks per Carton
Thickness
\\j"________ 2"
2H"
3"
1H" * 6" z 36" 2 " z 6" z 36"
2M" z 6" z 36"
24 18 14
62 64
64
Super-Light Segmental Blocks packed in Carton Type 47 with outside size of 14k" * 19k" * 36k".
Cu. Ft. - 6.315
12" 14" 16" 18" 20" 22" 24" 26" 28" 30#
Carton Size
8 14 10 8 9 16 12 8 10 16 12 8 11 16 12 12 16 12 13 16 12 15 16 12 16 16 12 17 16 12 18 16 12
12" to 18" md. packed in CN*5 (size shown above) ?0" rwj t ^
LaraaBiHM
j fa
PACKAGING TRI-SECTIONAL ALLTEMP PIPE COVERING
industrial insulation
CKAGING
Tri-Sectional Pipe Covering is packed in cartons for domestic shipment as shown in the following table:
I fe
PIPE DIMENSIONS FITTINGS AND FLANGES
industrial! insulation
Standard dimensions; wrought iron and steel^steam, gas and water pipe
Nominal internal
INCHES
16 H
* 1 1% 116 2 216 3 316 4 416 s 6 7 9 10 11 u
ttlAMETEK
Actual asternal
INCHES .405 .54 .875 .84 1.0S 1.315 2.66
1.9 2.37$
2.875 3.5 4.0 4.5 5.0 1563 6.625 7.625 8.625 9.625 10.75 11.75 12.75 14.0 16.0 110 20.0 22.0 24.0
Actoaf internal
INCHES
.269 .364 .493 .622 .824 1.049 148 1.610 2.067 2.469 3.068 3.548 4.026 4.506 5.047
6.065 7.023 7.981 1941
10.020 11. 12. 13.25 15.25
1745 1945 21.25 234S
NOMINAL THICKNESS
INCHES .068 .088 .091 .109 .113 .133 .24 .145 .154 .203 .216 .226 437 2*7 2S1 48 401 .322 .342 465
475 475 475 .375 475 475
CIRCUMFERENCE
TRILNSVERSE AJtEA
jExterna! . Internal
INCHES 1.272 1.696
2.121 2.639 3.299
4.131 5.215 S.969
7.461 9.032 10.995
12.566 14.137
1S.708 17.477
20.813 23.955
27.096 30.238
33.772 36.914
40.055 43.982 50.266
56.549
62.832 69.115
75498
INCHES .845 1.144
1.549 1.954
2.589
3.296 4.333 5.058 6.494
7.757
9.638 11.146
12.648 24.156
15.856 29.054
22.063
"21073 28.089 31.479
34.551 37.7
41.626
47.909 54.193
60.476 66.759 73.042
Extaraal Intarnal
M*ul
SO. INCHES SO. INCHES SO. INCHES .129 .057 .0717
.229 .204 .1249
.358 .191 .167 .554 .304 .250
.966 1458
.533 .3327 .864 .494
2.164
2.496
.668
2435
2436
.799
4.43
3.356
1.074
6.492
4.788
1.704
9.621
7493
2428
12.566
9487
2.679'
15.904
12.73
1174
19.635
15.947
1688
24.306
20.006
4.300
34.472
28.888
5484
45.664
36.738
6.926
58.426
50.027
8.399
72.76
62.766
9.974
90.763
78.855
11.908
108.434
95.033
13.401
127.677
113.098
14479
153.938 201.062
137.887 182-655
254.470
239.706
314.159
291.040
380.143
3S4.6S7
452490
424.558
LENGTH PIPE PER SQUAR t FOOT
External surface
Internal surface
FEET 9.431
7.07S 5.657
4.547 3.637 2.904
2.301
101 1.608
2428 1.091 .955
.849
.763 .686 .577
.501 .442
.396
455 .325 499
.273
439
412 .191 .174
.259
FEET
14.199 10.49 7.747 6.141
4.635 1641
1768
1372 1.848 1.547
1445 1.077
.949 447
.756 .63 444
.478 .427
481 447
419
488
450 421
.198 .180 .164
LENGTH
OF PIPE Contammi
1 cu-toot
FEET 2533. 1383.3 754.3 473.9 270.
166.6 964S 70.73 4191 30.07 19.47 14.57 11.31 9.03 7.198 4.91 172 1878 2494
1.826 1.51 147
NWOEMIGINHATL
PER FOOT
POUNDS 444 .42 .567 .850
1.115 1.678 12*4 1717 1609 5.793 7.575 9.001 10.665 12.538 14.671 18.762 23.271 21544
33.907 40.483 45.028 41985
Asbestos cement for standard fittings
THIf TIHC fives tht approximate number of pounds of asbestos cement which will cover standard scrawod flttinfs and flanfes 1 in. thick- It is based upon asbestos cement havtnf a covennt capacity of IS sq. ft l in. thick per 100-lb. bat.
H 85% Mapmia cement is used, one-fourth the amount wilt be repaired.
Where flttinfs era covered flush with adjacent 1-in. thick pipe covennt only approiimateiy tt-in. thickness required and consequently one-half the amount specified in this table.
for flanted flttinfs Spire the amount required for screwed fitimfs and in addition the amount required for the number of sets of Denies on each flanted Attinf.
Where sleeves of sectional ceverint or blocks are used around the outer surface of flanees only one-third the amount of cament specified in the table will ba needed for fillmi cracks and fillinf m space between such sleeve and the outer surface of l-m. thick pipe covering
For 45-defree ells approsimateiy one-haIf the amount specified for 90-decree ells will oe required.
For ion; radius His approximately two times the amount specified for 90-detree efls will b required.
NOMINAL PIPE SIZE. INCHES
K. *. and 1.., 1%. 116. and 2. Z'A end 3........ 3W and 4........ 4ft and 5___ :
6.............
7........................
8.............
9......................
10............
12....................
POUNDS ASBESTOS CEMENT
* ELLS
VALVES ANO TEES
CROSSES
ONE PA FLANGE
2.0 15 17 4.5 3.5 44 4.7 11 6.0 75 10 19 9.0 113 110 111 115 15.6 117 14.1 15.0 118 20.0 114 115 23.1 24.3 19.0 19.5 244 26J) 210 24.0 X.0 310 26.0 29.0 311 319 275 37.5 47.0 510 38.0
Fittings and Flanges--Insulation Areas
PIPE SIZE INCHES
2ft 3
3* 4 4ft
i .6
7 9 10 12 14 16 18 20 22 24 26 28 X
FURMO FITTIMS
AVERAGE SO, FT.
AREA OF
SO. FT. CEMENT
METAL SURFACE USED SOLID
0.7 15 05 U 1.0 15 14 17 15 1.9 1.7 11 24 16 2.7 34
34 35 4.0 45 45 55 64 18
13 9.0 17 105 110 135 145 155 174 11$ 21.0 224 24.0 25.0 27.0 285 305 315
PIPE SIZE INCHES
2* 3 3* 4 4* 5 6 7 8 9
10 12 24 16 18 X 22 24 26 28 X
ruNtcs
SQUARE FOOT 8LOCKS
25 14 1.4 1.6 1.7 U 11 14 17 11 3J 4.4 4.8 10 18 7.7 17 105 115 135 145
SO. FT. CEMENT A THICK OVER
m* SLOCKS
14 16 17 19 3.0 34 35 45 45 4.8 54 17 7.0 95 110 11.0 112 114 14.7 110 110
tC MCTAl IAEA to sacure tret of Mocks.
For area of 16-in. cament over 1-io. Mock use 13316*01 metal area.
For area of 16-in. cement ever 116-in. Mock use 140* of metal area.
For am of ft-ia. cement aver 2-in. Mock use 150* of motel am.
The second column under flttinfs indicates the square-foot area of Mocks required to caver them while the third column shows the square-foot area of comont usod solid.
TNI SMOKO WtOMN VN0CI FlANStt indicafts the sqssre-foot ares of Mock insulation required to cover them, while the third column shows the square-foot area el cement 16 in, thick nod over lV6*in. thick blocks.
H| UTg"!
PROPERTIES OF SATURATED STEAM STANDARD AREA TABLES
industrial insulation
HEAT UNITS NEAT OF
TOTAL
PRESSURE TEMPERATURE IN LIQUIO
IN POUNOS IN DEGREES ABOVE
persq. men
F.
32* F.
VAPORIZATION HEAT UNITS
(LATENT IN STEAM
HEAT)
ABOVE
32* F.
DENSITY POUNDS
PER CU. FOOT
SP. VOL CU. FOOT PER POUN0 STEAM
$ 10 14.7
40 SO
CO
70 SO 0 100
no
120
rm
"" ISO
ISO 170 ISO ISO 200 22$ 2S0 27$ 300 38 290 37$ 400 42$ 450 47$ 900
" $ v S50
S7S too <2$ 490 67$ 700
16238 1*122 212.0 221.0 2503 2*73 2S1.0 292.7 3023 3123 3203 3273 3344 3413 347.4 3934 ' 398.5 3*3.6 36S3 373.1 3773 3S13 3S13 401.1 4093 4173 424.7 4313 438.4 4444
450.7 45*3 4613 4*7.3 4723 4773 4*2.0 4*6.6 4903 4953 4993 501.4
mi 161.1 186.0 196.1 2183 236.1 250.1 2611 2716 2*10 2903 2913 3053 3113 3116 324.6 3303 3316 3417 345.6 3514 3543 3610 3712 3S4.0 3917 4003 4012 411 421 429. 431 441 441 454. 459. 464. 469. 474. 471 4S4. 4*7.
10013 9H0 9714 MOO 9411 9333 9233 9143 9073 9003 m3 S810 8H5 8773 8713 867.6 8*33 SSU 8917 8503 8463 8433 SSU 8263
Bill
*U3 8043 7973 791 781 781 774. 7H 761 757. 791. 741 741. 731 721 717. 711.
11315 11411 11914 11563 11619 110.4 11733 11710 11793 11823 1184.4 118*3 11883 11816 11913 11923 11914 11X3 11*5.4 11914
11973 11911 11918 12013 12023 1204.1 12011 12011 1207. 1201 1201 1201 120. mi 1211 mi mi mi 1201 1201 1191 1191
101364 102606 103732
10728 1003 1117$ 11394 11612 11829 12044 12298 03472 03*83 0307 13107 13320 13929 03738 13948 141S7 1437 140 0341 1913 0345 030 1790 031 10 191 036 132 131 U4 130 136 132 137 1.41 1.47 132
733 314 218 211 117 103 83 73 63 S3 43 4.4 43 17 IS 33 10 23 23 23 2.4 23 11 13 1.7 13 13 13 13 13 LI
13 13 19 03 IS 18 18 17 17 C.7 17
Absolut* prtswn=|tui* prosur*+14J.
THE STEAM TASK ABOVE is reprinted f* port from Marks and Davis, Tibia* and Disframs of the Thermal Proeortias of Satereted sod Seperheated Steam" by permasoe of tba pfbhtJwrs Mtssrs. UaCBNfc Grten A Co.
T1SUATIMKT
Araat tor Flat, Conrad and Taparad Mocks S in. widt. For 34a. wida blocks multiply i' shown bp 03. For 9-ia. *da Mocks mettiply area shown by 13. For 124r. wide Mocks multiply area shown by 2.0. ftatain sH daamals in all eases.
For B/oefcs and Lagging
FLAT BLOOM THICKNESS
CfRVEO 810*1--OVER 16H-IN. RADIUS*
LESS THAN m INCHES
OVER
m TO 2 INCHES 2 INCHES
INCHES INCLUSIVE
LENGTH BLOCK AREA BLOCK AREA BLOCK AREA SLOCK AREA BLOCK INCHES SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET
* 302 302 Mi 302 302 302 302
ft 30 30 30 30
ft 310 310 312 38 % 316 316 316 316
ft 3 322 38 38 ft 326 328 3a 38
96 332 332 334 334
ft 336 338 338 30
t 342 344 344 364
2 304 30 30 30
3 .126 332 48 434
4 30 4ft 47* 47B
$ 30 320 38 324
6 390 364 30 30
1 392 30 310 312
8 334 30 394 30
t 376 394 30 302
10 411 338 342 30
11 AH 382 30 38
12 30 326 38 30
13 342 370 37* 38
14 384 414 30 38
15 32* 30 364 3a
16 364 402 40 J16
17 30 .70 48 40
IS 350 40 40 30
19 .792 332 342 30
a 334 376 30 30
21 376
J3Q 38
22 316 30 374 30
S 398 1.00 1318 138
24
1.00
1392.
1362
1372
a 1.012
130
1.10
141*
a 1384
1.10
148
L18
ua27
L164
L10
130
a 1.10
13
130
138
a 130
1372
130
130
a 1390
1316
138
1342
31
1392
130
1372
130
32
1334
1.402
L416
L430
33 1379
1.416
1.40
130
138
a 1.40
1334
130
130
a
130
1371
13M
1310
37
1342
L622
138
1354
1.60
1.68
LBt
a 1326
1410
1426
1.744
uaa
130
1454
140
41
130
140
131$
138
42
1350
1342
130
1477
PACKAGING DATA
industrial insulation
j freight tables
/innate freight in per cent of list price for any rate of freight multiply the percentage given
.e freight rate in dollars:
example, to determine the cost of Magnesia covering when the freight rate is 35c per cwt.: .0 % X $0.35 = 1.75 % of the list price.
FOLLOWING TABLE shows the approximate freight cost for various coverings in per cent of list based on $1.00 per cwt. freight rate.
,o Magnesia Blocks................................... 6.0% % Magnesia Covering............................... 5.0% \lltemp Covering........................................... 5.0% Alltemp Blocks............................................... 6.0% Air Cell Covering (2-ply)............................. 1.9% Air Cell Covering (3-ply)............................. 2.8% Air Cell Covering (4-ply)................................ 3.5% Carocel Covering (%' th.)........................... 2.9% Carocel Covering (%' th.)........................... 5.0% Carocel Covering (1* th.)................................6.0%
Hi-Temp No. 19 Blocks................................. 8.5% J
Tempchek Pipe Covering............................. 7.5% '
Impervo Covering
th.)........................... 3.3% f
Impervo Covering (%' th.)..............................4.6% f
Impervo Covering (1' th.)............................. 6.3% ^
Multi-Ply Covering (l'th.)........................... 8.5% r
Perfecto Covering (%' th.)......................... 3.0%
Perfecto Covering ($4' th.)......................... 4.3% l
Perfecto Covering (1* th.)............................. 5.9% :
Protecto Covering (1* th.)......................... 5.0% L
Asbesfos Paper weights and measurements
WEIGHT PER
ONE POUND
WEIGHT OP
100 SQUARE FEET WILL COVER ONE SQUARE FOOT
POUNDS
SQUARE FEET
POUND
THEORETICAL GAUGE
65 LBS. PER CU. FT.
INCHES
AVERAGE ACTUAL GAUGE
INCHES
FRACTIONAL SQUARE FEET THICKNESS PER 100 POUNDS
6 16.66 7 14.28 8 12.50 9 11.11 10 10.00 12 8.33 14 7.14 16 6.25 20 5.00 24 4.16 32 3.12 48 2.08 64 1.56
.06 .07 .08 .09 .10 .12 .14 .16 .20 JU .32 .48 .64
.0109 .0127 .0145 .0163 .0181 .0218 .0254 .0290 .0363 .0435 .0581 .0872 .1162
.015 .017 .019 .021 .022 .027 .029 .032 .039 .046 .060 .089 , .125
...
1/64
... . ... ...
1/32
...
3/64 1/16 3/32
1/8
1666 1428 1250 1111 1000
833 714 623 500 416 312 208 156