Per your request, I have attached a copy of "A/C Pipe and Health" which should answer any questions you have. I have also attached a copy of a recent letter from the EP.A Division IV which put out an opinion on pipeline materials for Lakes!and, Florida when a concern was raised over asbestos and water.
..
If you have any further questions, please do not hesitate to call.
Yours '-------- i --
C. B. Woodworth CBW:mf Attachments bcc: Mr. A. B. Stapp II
Quality Piping Materials
CAPCO JEN 0026271
i* /til ;
>4$ coiiuri.AND cTnncr ATLANTA, GCOfJGIA 2-jyoa
August 20, 1900
KEF: 4W-KS
#
Mr. T.B. Williams, Superintendent
Water Division
Department of Electric and Water Utilities
P.O. Box 368
1000 East Parker Street
Lakeland, Florida 33802
Dear Mr. Williams:
Thank, you for your letter of August 6, 1980, requesting information about
various pipeline materials which are under consideration for the Lakeland
distribution system upgrading. We have attempted to answer your questions in
detail, expressing what, in our opinion, is the direction of the Environmental
Protection Agency's thinking on these various materials for use in potable
water application. The answers to your questions are enclosed as an
attachment to this letter.
_
If I can be of further assistance in this matter please contact me.
Sincerely yours,
^
Enclosure Response Paper
/
CAPCO JEN 0026272
JlKSPOHSE TO LAKELAND FLORIDA QUESTIONS CONCERNING
POTABLE WATER PIPE MATERIAL
'
August 20, 1900
'.
i* The ag'cncy has done no research Into cement lined ductile pipe. .The seal coat, applied in order to promote proper cure o the cement, is 'usually a petroleum based material obtained from the "bottom" of the distillation process. We have on record, in Region IV, one instance in which this coating material was found to be contaminated with low levels o polychlorinated biphenyl (PCD). The agency does not have the resources necessary to determine if contamination such as this occurs frequently. It is not expected to be the normal situation, but it is an example of a problem which might occur with this type of pipe.
Iron pipe lined with various types of coating material, other than cement, is also widely used in the water supply industry. Coating materials used are, coal tar derivatives, vinyl, epoxy and other types of resin based coatings.
The agency, in an ongoing study, has monitored water coming from a large water storage tank to which a coal tar coating was applied. More than twenty organic compounds which could be directly attributed to the coating material have been detected in the water. A. number of these were polynuclear aromatic compounds (?AC). The health community has expressed concern about human consumption of PAC in -general because several are known or suspected human or animal carcinogens. In the current study, even .after more than two years of continuous use PACs are still detected in the water at approximately one tenth (0.1) the original concentration.
In a situation with a vinyl coated pipe material the solvent that was used to clean the pipe and thin the coating, for application was found to be present in the water at the parts per million level. Studies looking for vinyl chloride in water from vinyl coated pipe have not been conducted at this time. Thus, the possibility for vinyl chloride contamination of water passing through such pipe is only conjectured.
The agency has expressed concern for the fact that nany epoxy coatings use epichlorohydrin in their formulation since this compound has been determined to be a carcinogen. A study to determine if this material is present in water contacting epoxy coatings will need to be conducted in order to determine the significance of the agency's concern.
Many coating products have components for which the agency health effects personnel have concern when considering long-term human consumption even ^^fc. very low concentrations because of their identification as known or suspected human or animal carcinogens. As indeed these same individuals have a similar concern for the long-term ingestion of asbestos fibers.
CAPCO JEN 0026273
-2-
%
2. An agency study of Installed polyvinyl chloride (PVC) pipe found low levels of vinyl chloride in the water after transnission through the Main. Vinyl chloride has been linked with increased incidence of liver opgiocarcoma among the vinyl chloride industry employees. Doth long-term and high level exposure to vinyl chloride has produced the same type tumors in laboratory animals. The National Academy of Science (NAS) assessment is that, vinyl chloride is a human and animal carcinogen. The NAS assessment of carcinogenic risk to the human population indicates that there would be a risk of one additional cancer per million persons consuming water containing 2.1 micro-grems per liter for a life time.
Other plastic materials have not received wide spread use in the water
supply industry for pipe diametersto which you refer; therefore,
discussion of the appropriateness of their use in your system will not be
addressed.
' *
. *"j* i *
3. The agressiveness of the water has no known affect on :tho leachability of
chemical components from PVC pipe or the various coating materials
previously discussed. The leaching process will occur, on a continuous
basis, from the pipe or coating into the water based completely upon the
laws of physical chemistry. The driving force for the transfer from the
pipe or coating (organic phase) into the v?ater is* the difference in
concentration for a given component in each phase. This force is
independent of the agressiveness of the water. On the other hand
asbestos-cement pipe suffers dissolution of the cenent ina chemical
reaction in which the cement is dissolved releasing the asbestos fibers
which is very dependent upon the chemical qualtiy of the water,
specificly its agressiveness.
4. .Since, as indicated previously, there is some health risks associated v?ith use of most of" the pipe materials in question, it 'would appear that selection should be toward the one in which the suspected health risk can be reduced or eliminated. Since the problem with the coatings is a leaching of contamination from the film into the water and independent of water quality, and the problem with the asbcstos-cemcnt pipe _i dependent
upon the water quality which can be (and in the proposed application will be) controlled through treatment, then it would appear that the pipe system with the least negative health effect prospects would be the asbestos cement pipe.
4Thc chemical reaction between water and cement has been successfully stopped by two methods.. One is the application of treatment which alters the agressiveness of the water so as to make it nonagressive (as defined by the equation for the Agrosr.ivc Tndex). The other is the addition to the water of a nine salt which allows the formation oC a nine hydroxide pcfcipltato on the pipe wall thereby establishing a x>rotective barrier between the water and pipe.
CAPCO JEN 0026274
3* -
Vherc treatment to adjust, the water quality so that it Is no longer
/igrcssivo is available/ this is the best approach in controlling apbestos
cement pipe degradation.
f
The health risk associated with *use of any of the pipe systems discussed
would indeed be very small. The general order of increasing health risk
for nonagressive water would be asbestos cement less than cement lined
less than polyvinyl chloride, vinyl coated, epoxy coated, other res.in
base coated, with coal tar coated the greatest.
%
.*
t
The fact that Lakeland has several hundred miles of asbestos cement pipe
already in use should not influence the decision to use asbestos-cement
pipe in the proposed project. VJhat must be considered is how will the
use of such pipe in this project impact the public health. From the
proposal it is clear that the utility intends to use this pipeline to
convey only stable nonagresseive water to its customers. Thus, the pipe
would not degrade and asbestos fibers would not be present in the water
and the public health would not be endangered.
The facts have been established by SPA studies that asbestos-cement pipe has been used across the United States for many years conveying nonagressive water without the slightest indication of deterioration or {jsbestos fibers in the water. However, agressive waters have been found in many places to cause pipe deterioration resulting in asbestos fibers in the water.
Lakeland's drinking water is of such quality that there is indication that asbestos-cement pipe deterioration has apparently already occurred in the 300 miles presently installed. The utility's plans for construction of a complete treatment facility, which will provide steblised water that will put an end to further pipe deterioration, should be quickly accomplished in order to eliminate whatever asbestos fiber health hazard that may presently exist,. ,