Document 54L8yOr5QvBz76Veb9wdZq45

American Society of Heating and Ventilating Engineers Guide, igjj proportion of the actual efficiency with the gas being burned to assumed efficiency of 80 per cent. Oil-Fired Boilers The output of a boiler with oil fuel will depend upon the combi efficiency of the boiler and burner and the quantity of oil that c*n burned properly within the space provided in the boiler. Oil burner ratings in use at present have been obtained either fro tests with typical burners or have been obtained by multiplying the rating by a constant. BOILER SELECTION Ordinarily, especially in residence heating and in other small install* tions, the information upon which the boiler is selected is meager. Thi information usually covers the heat output of radiators under nornia temperatures, the kind of fuel, whether anthracite or bituminous coal oil or gas, and in a few cases the amount of heat-emitting surface in thi piping. Successful selection of a boiler based only upon this informatioi requires good judgment and the boiler usually must be selected largi enough to deliver the required quantity of heat under the most advers conditions of attention, fuel, draft, etc. A boiler usually is selected from I the manufacturer's catalog with , rating 80 to 100 per cent in excess of the manufacturer's rating express^ in equivalent square feet of direct radiation. The following items taken from the American Society of Heatini and Ventilating Engineers Code of Minimum. Requirements foi the Heating and Ventilation of Buildings cover information whicl should be available for intelligent boiler selection: 1. The estimated heat emission in B.t.u. per hour of the connected, radiation (direct indirect or blast) to be installed, as previously determined by' calculations given ii Chapters 3, 4 and 5 of The Guide. 2. The estimated maximum heat in B.t.u. per hour required to supply water heater or other apparatus to be connected to-the boiler. 3. The estimated heat emission in B.t.u. per hour of the piping connecting the radiation and other apparatus to the boiler. 4. The estimated increase in the normal load in B.t.u. per hour due to starting up cold radiation, etc. This percentage of increase to be based on the sum of items (1), (2] and (3) shall not be assumed less than the following: Sum of (1), (2) and (3): \. Up to 100,000 B.t.u. add 65 per cent. 100.000 to 200,000 B.t.u. add 60 per cent. 200.000 to 600,000 B.t.u. add 55 pier cent. 600.000 to 1,200,000 B.t.u. add 50 per cent. 1,200,000 to 1,800,000 B.t.u. add .45 per cent; Above 1,800,000 B.t.u. add 40 per cent. Other things to be considered are: - 5. The kind and amount of attention available. Attention is least skillful and least frequent for owner-operated residence installations and generally increases in - skill as well as frequency as size of boiler increases. Local fuels and types of firing service must be considered carefully in this connection. 6. The kind of fuel to be used, including size and characteristics. 7. Size and.height of the available chimney, 218 Chapter 13--Boilers K. jpgnite requirements as given by items 1 to 4 available, the boiler BMP qe information, obtained according to American Society of Ventilating Engineers Performance Test Code No. 3 .. iipa ting Solid Fuel Boilers, can be used for selection of of solid fuel burning boiler. Wtr Fectors in Selection of Boiler L~ *t will usually be found that several boilers will meet the specifica- *the fina[ selection of the boiler will be effected by other considera- lai'i'Ds ifmolelonnwssiisoo:nnss ootf bDooinleerr;; (\ub)j Height of w..--ate.r..l.i.n..e..; (wc) Durability under Kj*. (d) C"onv---eni'--en~ce in" ffiriri'inntgr aanndd cclleeaanniinngg;; ({ee)) TTyyppeeooffccoonnttrroollss;; ((//)) '^Fotability to changes in fuel and kind of attention; (g) The output required during the greater part of the season. t In large installations the use of several smaller boiler units instead of larger one will obtain greater flexibility and economy by permitting * - Me operation of a required number of units according to heat require- ^mentkat the best operating efficiency. Humerical Value of Maximum Hourly Output Experience with gas-fired boilers, which are rated on B.t.u. output and fe which can only slightly exceed the rated output, but which require no chimney draft, has shown that a continuous output capacity of 25 per cent * in excess of the normal heat loss of radiation, plus piping, is ample for all direct radiator installations. This corresponds to an output of 40 to 60 percent in excess of the normal heat loss of the radiation, depending bpon the proportion of piping to radiation. : Gasfired boilers rated according to the American Gas Association method and having, therefore, A.G.A. Ratings are selected in the majority pf direct radiator installations, according to the table of selection factors given in Chapter 17, page 279. Upon the basis of gas-fired boiler experience, a coal-fired boiler which could deliver a continuous average output of 25 per cent in excess of L-radiation and piping would be amply large for any job. This is true for >ah oil-fired boiler, provided the known output of the combination of boiler, 'burner, and chimney is used. ^ -SAWhere test data are not available for the contemplated combination of-boiler and oil burner, economical performance may be obtained by selecting a boiler in which the heat absorbed per square foot of boiler heating surface at the maximum continuous output is approximately 4,000 B.t.u. per hour. It should, be ascertained that the. burner selected has sufficient combustion space to permit the burning of the required quantity of the available oil fuel. fu the case of coal-fired boilers, however, it is necessary to make addi tional allowance for the following conditions not due to boiler construc tion which may . obtain at the time when the maximum pick-up load 2^5' ^ insufficient draft; (b) poor quality of fuel; (c) fuel bed not in . igood condition; {d) inferior quality of attention; (e) necessity of firing AcharSe f fuel that will last for a long period; (/) dirty flues. ,^-The conditions (a) to (/) inclusive, reduce the output obtainable to a 219