Document 52Ld57zYyBgn8D5N9gjz73QJ
[Conoco
RETURN RECEIPT REQUESTED
I^TDeNTOTjfr TZQV&TQ)
October 31, 1980
Oe-fakr2>l) |90O
Cor 6to
CfrttrOM^/
Conoco Chemicals Company
/
A (Division of Conoco InC
PO Box 605
Westlake. Louisiana 70669
I318J 491-5211
(318)191-5271
Ms. Adlene Harrison, Regional Administrator U. S. Environmental Protection Agency Region VI 1201 Elm Street Dallas, TX 75270
Dear Ms. Harrison:
The following is a report of two relief valve discharges to the atmosphere at the Conoco VCM Plant in Westlake, Louisiana as required by Section 61.65, Part 61 of the National Emission Standard for Hazardous Air Pollutants, Standard for Vinyl Chloride. Two relief valve discharges occurred during a plant startup: the first discharge was on October 24T 1980 and the second discharge was on October 26, 1980. At approximately 5:45 a.m., October 24, a Causric Decanter overpressured due to a valve misalignment and its relief valve discharged for not more than three minutes. At approximately 1:30 a.m., fletObgj^ZS-r-the Quench Column overpressured due to an emergency shutdown on a cracking furnace and its relief valve discharged for not more than one .minute. There was no employee exposure from either discharge.
The Caustic Decanter relief valve discharge was from a 3x4 Consolidated Type 1905-30LC relief valve with a set pressure of 115 psig. The Quench Column relief valve discharge was from a 6x10 Consolidated Type 191O-30RC relief valve with a set pressure of 150 psig. The Consolidated Relief Valve Catalog No. 19003, Page 47, was used as the reference for determining the amount of
the discharge. The Caustic Decanter relief valve discharged approximately
2,500 pounds of vinyl chloride to the atmosphere during a 3-minute period. The Quench Column relief valve discharged approximately 5,475 pounds of vapor including 1,990 pounds of vinyl chloride to the atmosphere during a one minute period.
Corrective action was immediately taken to remove the cause of the Caustic Decanter overpressure by opening a block valve to correct the valve misalignment.
Please let me know if you have any questions concerning this report or require any additional information.
Sincerely,
l/ J. A. DeBernardi Plant Manager
{
is CC: Gus YcnScduncen - DONR BCC: REL-CRH-JHN-VAM-GLF-PLF-DLD-JWW-JCL-JGC
CCR 000023598