Document 50y8oBKkYapzezYw9QNB9pbz
A4i.r S_ystem E_quipment AanirdFcilletearnsers Air Recovery
W. B. CONNOR ENGINEERING CORP.
Danbury, Conn.
Representatives in All Principal Cities
In Canada: Douglas Engineering Co., LtcL, Montreal, P. Q.
Air Recovery
ffpREX)
Air Purification
WHERE TO APPLY AIR RECOVERY
Air Recovery is simply the conversion of foul or stale air to fresh air. It has been used to advantage wherever air is conditioned to enhance comfort, raise production efficiency, extend food preservation or protect product quality. Depending on the source of contamination, Dorex Air Recovery Equipment nas been installed to remove
odors and other gaseous impurities from intake air, from recirculated air or from exhaust air.
When applied to recirculated air, Dorex Adsorbers reduce the amount of unconditioned outdoor air needed for ventilation and effect savings in in stallation and operating costs. For example: Given an air conditioning requirement of an area of 20,000 cfm, of which it is assumed 14,000 cfm would be recirculated and 6,000 would be outdoor ventilation before installation of Air Recovery Equipment, it may be possible to cut the amount of unconditioned outdoor air intake to 2,000 cfm by converting 4,000 cfm of used, already condi tioned recirculated air to fresh air. Figured for average temperate zones, this 33^ per cent load reduction would lower the installation and operat ing cost substantially because each 1,000 cfm of heated or cooled air that is converted saves: (1) 100,000 Btu of installed heating capacity, (2) 2.6 tons of installed refrigeration, (3) 1,800 kw hours of current per cooling season, (4) 1,500 gallons of fuel oil or 9 tons of coal, and (5) incidental water consumption and maintenance.
In existing systems, the application of Dorex Air Recovery Equipment will enable the system to serve a larger space or satisfy a greater condition ing load without increasing cooling or heating equipment and without consuming more fuel or power.
Activated Carbon Traps Gases and Odors
Activated carbon removes gases and odors by ad sorption--a natural phenomenon which takes place when air-borne gases or vapors come in contact with it. An instantaneous condensation occurs and the condensed impurities are held tenaciously until the carbon is forced to give them up in reac tivation. For air conditioning purposes, however, the carbon must be especially processed, activated, and impregnated to meet the following specifica tions: (1) High activity (adsorptive capacity) for a wide range of gases and vapors; (2) High retentivity over an entire range of normal operating conditions; (3) No retentivity for water vapor; (4) Extreme hardness to avoid dusting in handling and in service; (5) High apparent density (in the granu-
^Fig. t Typical Canister Arrangement--tide tiers
1170
W B. Connor Engineering Corp.
Air Filters
Air System Equipment
lar form) of not less than 0.45; (6) Adaptability to repeated re activation without appreciable
loss in activity or retentivity. In actual use. Dorex activated carbon has removed and re
tained 95 per cent of all gaseous impurities from the air passed through it and maintained that
efficiency from six months to
two years, depending on the air contamination.
Equipment to Suit Individual Requirements
Dorex Air Recovery Equipment
is available in a range of types
and sizes to suit individual re quirements. Each type is de
signed to hold the correct amount of activated carbon in a manner to provide a maximum area for decontamination, a
minimum of air resistance and
uniform air flow through the carbon. The average resis tance to air flow ranges only
from 0.15 to 0.2 in. wg.
TYPE H--Adaptable to Most
Central Systems for Recovering the Freshness of Intake Air and Recirculated Air and for Eliminating Exhaust Nuisances
Fig. 3 Dorex Type C Air Recovery Cell
Type H Equipment--for com plete decontamination of all
air passed through it--con sists of removable, perforated,
carbon-filled canisters which are mounted in multiple on
one or more supporting mani fold plates. Fig. 1 shows a canister and its function; Fig. 2
shows a typical arrangement of
canisters as installed. The
flexibility of this arrangement makes Type H Equipment read ily adaptable to a wide variety
of space limitations.
Fig. 4 Dorex Q panel
TYPE C--Equipment for Recovering the Freshness of Recirculated Air.
Dorex Type C Air Recovery Cells were developed to meet a need for a large capacity, easily handled and installed air purification unit. Each cell measures only 24 in. x 24in.x8f in. deep and completely purifies 1,000 cfm. They require no more engineer ing than that required for ordinary dust filters and can be mounted right along with
them in either flat or "V" arrangement. (Fig. 3)
TYPE G--for "Package" Conditioners, Unit Heaters, Refrigerated Spaces, Airplane, Bus, Railway Car, and Marine Installations and Other Systems Where Space Is
at a Premium.
These compact panels consist of sturdy metal frames, each housing a battery of exposed perforated metal tubes which contain the activated-carbon. Standard units of one, two or three tube rows in depth are available in a range of stock sizes
for arrangement in air ducts. (Fig. 4)
1171